05000298/LER-1980-043-03, /03L-0:on 801021,motor Operated Valve SW-MO-89B Failed to Open.Caused by Broken Wire Connected to Ohmite 1000-ohm Variable Resistor Inside Valve Operator.Broken Lead Resoldered & Circuit Checked

From kanterella
(Redirected from ML20002B935)
Jump to navigation Jump to search
/03L-0:on 801021,motor Operated Valve SW-MO-89B Failed to Open.Caused by Broken Wire Connected to Ohmite 1000-ohm Variable Resistor Inside Valve Operator.Broken Lead Resoldered & Circuit Checked
ML20002B935
Person / Time
Site: Cooper Entergy icon.png
Issue date: 11/20/1980
From: Bednar L
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20002B934 List:
References
LER-80-043-03L, LER-80-43-3L, NUDOCS 8101070353
Download: ML20002B935 (1)


LER-1980-043, /03L-0:on 801021,motor Operated Valve SW-MO-89B Failed to Open.Caused by Broken Wire Connected to Ohmite 1000-ohm Variable Resistor Inside Valve Operator.Broken Lead Resoldered & Circuit Checked
Event date:
Report date:
2981980043R03 - NRC Website

text

NRC. ACRM 366 U. S. NUCLEAR REGULATORY COMMISSION

.47 771 LICENSEE EVENT REPORT CCNTROL BLOCK: l l

l l

l l

lh (PLEASE PRINT oR TYPE ALL REQUIRED INFoRMATION) lo l t l l N I El Cl Pl Rl 1l@l 0l 0l-l 0 l 0 l 0 ] 0 l -l 0l 0l 0l@l4 l1 l 1 l 1l 1l@l l

lg 7

3 3 UCENSEE CODE 14 15 UCENSE NvYBER 25 2ti UCENSE TYPE 30 S i CA T 2d CON'T loIil 3g[,

l L @l0 l 5 l0 [ 0 l 0 l 2 l 9 l 8 @l1 l012 l1 l 8 l 0 @l 1l 1l 2l O! 8l 0l@

  • E 7

8 60 61 DOCKET NUMBER tW 69 EVENT D ATE 14 75 REPORT C ATE 80 EVENT DESCRIPTION AND PROBABLE CONSEOUENCES h lol:1 puring Surveillance Test, SP 6.3.20.1, motor operated valve SW-MO-89B failed to openp ioi3i [This valve is controlling flow when RHR service water pump 1B or ID is running.

l 10 6 41 l(T.S. 3.5.B.2) This event had no ef fect upon public health and safety.

Redundant l

lo!si l systems were available. This event is not repetitive.

1 I) is i I i

13171 l l

Iois 1 I I

.0 SYSTEM

CAUSE

CAUSE COVP.

V ALV E CODE COCE SLSCOCE COMPONENT CODE 3L8 CODE SU8 CODE lojal lW l A lh W@ l A l@ l V l Al Ll Vl Ol Pl@ l Xl@ ]@

7 8

9 10 si 12 IJ TH I '>

20 SEQUEN TI AL OCCUR RE NCE REPORT REVISION

_ EVENT VEAR REPORT NO.

CODE TYPE NO

@ =LE R RO i 81 01 1-1 1014I31 Ld I of 31 i Ll l_]

[0_J g

_ 21 22 23 24 26 27 29 29 30 31 J2 TAK N ACTO ON PL PT VET HOURS SB IT FOR 8

$UPPLIE VANUFA URER LtJ@LnJ@

L7J@

LzJ@

l01010101 L3]@

l I@

l zi@

Iz 191919 l@

JJ 34 33 36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 17 l o i lone of the 3 wires connected to a OHMITE 1000 ohm variable resistor counted inside l IiIi1 Ithe valve operatcr was broken. The broken lead was resoldered and the circuit check 1 ii,,i led. The valve was retested and its operation verified. Valve SW-MO-89A which is in I l i 131 I the second loop was also checked. The exact cause of the broken lead is not known. I lilal lThic f ailure in considered nno of a kind and uniaue.

I a 9 80 ST 5

  • . POWE R OTHER STATUS 015 OV RY DISCOVERY DESCRIPTION lil5IIEl @ l Ol 9l 7l@l NA l

l Bl@l Surveillance Test l

A TlVITY CONTENT aELE ASED OF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELE ASE NA l

l NA l

li 16 I LzJ @ Lzl@l 1

9

')

10 11 44 45 80 PERSONNEL EXPO $VAES NUYBER TYPE

DESCRIPTION

li l 71 L010101@l zl@l NA l

ERSONN A'~uh5 o ESCR,P T,0~ @

Num.

Ld_] 1010101@l NA l

M 1 11 12 80 t J.J

  • n OH D AMAGE TO F ACILiTV fvPE

()ESCHIPTION NA I

I t 191 Lzj@l r

A

<r 10 80 sv U t t HsPitON 2

'I MA

!!!llllll!!!

i it

'J 10 68 69 80 3 Ladislav F. Bednar 402-825-3811 o

NAME OF PAEPARER PHONE-8101070353