ML19350B971
| ML19350B971 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 03/19/1981 |
| From: | James Knubel JERSEY CENTRAL POWER & LIGHT CO. |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19350B972 | List: |
| References | |
| NUDOCS 8103240515 | |
| Download: ML19350B971 (2) | |
Text
u" Jersey Central Power & Light Company JC L
GPU Madison Avenue at Punch Bowl Road Mornstown, New Jersey 07960 (201)455-8200 0$\\Wj)'%,
e 9#
March 19, 1981 D\\
P $v 2-
'%N9 l'. _
\\
~
C g
$F
,i e-M.
c.
Director lae ua Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D. C.
20555
Dear Sir:
Subject:
Oyster Creek Nuclear Generating Station Docket No. 50-219 Technical Specification Change Request No. 88 In accordance with conversations conducted between your staff and Jersey Central Power f, Light Company, please find attached a revised page 4.7-la of Technical Specification Change Request No. 88.
The revision stipulates that the specific gravity for the station batteries shall be greater than or equal to 1.190.
If additional clarification or information is required, please contact the undersigned at 201-455-8753.
Very truly yours, ames Knubel Licensing-Manager la Attachment f
ODI 5
//
81032.405/5 g
Jersey Central Power & Ught Company is a Member of the General Public Util:ttes System
.