ML19332F372
| ML19332F372 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 12/08/1989 |
| From: | Tucker H DUKE POWER CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NUDOCS 8912140341 | |
| Download: ML19332F372 (10) | |
Text
m.
4+
ll!
I L
Duke Fruer Company llu11 ksa PO Ikx 33198 Vice President
- i s.
Charlotte, NC 28242 -.
. Nuclear Production (701)373 4531
'DUKEPOWER
.)
December.8, 1989 U..S. Nuclear Regulatory Commission
' Attention: Document Control Desk Washington, D. C.
20555
Subject:
Catawba Nuclear Station, Units 1 and 2 Docket Nos. 50-413 and 50-414
. Priority Listing of Operating License Amendments Gentlemen:
Attached is an update of our March 31, 1989 listing of proposed Operating License and Technical Specification amendments. Amendments submitted to the NRC have been prioritized according to significant milestones 6
associated with the desired issuance date, impact on station operation, and significant improvements to existing Technical Specifications.
Attachment I is a listing of amendments that have a significant milestone q
associated with the requested issuance date. Attachment II is a listing of amendments required to improve the efficiency-of station operation and j
which significantly clarify the existing Technical Specifications.
Attachment III is a listing of the remaining amendment requests which have been submitted to the.NRC. Attachment IV is a listing of License amendments which are being developed and will be submitted to the NRC in the near future. Attachment V is a listing of relief requests submitted to the NRC.
r This listing is intended as guidance to be used in allocating resources for the review and issuance of proposed amendments. The listing is not intended to preclude the pursuit of other Operating' License Amendments or l
d Technical Specification Amendments which may need to be given a higher priority. This listing will be periodically updated.
1 If you have questions or comments concerning this priority listing,
please advise.
Very truly yours,
^f u.dteker JGT/5/TSNRC Attachments p[
r i
8912140341 891208 PDR ADOCK 05000413 P
PNU
=
k-:
i
- e.
"Y s
~s U.- S. Nuclear Regulatory Commission December 8;-1989 Page Two xc:
Mr. S. D. Ebneter Regional Administrator, Region II
-U. S. Nuclear Regulatory Commission 101 Marietta St., NW, Suite 2900 Atlanta, Georgia 30323 Mr. W._T. Orders NRC Resident. Inspector Catawba Nuclear-Station-Dr. K. N.'Jabbour Office of Nuclear Reactor Regulation U. S. Nuclear regulatory Commission j
One White Flint N.
1 Mail Stop 14H25
. j Washington, D. C.
20555 a
i l
)
I
rm r
- 6 AT1'ACllMENT I (Page 1 of 1)
CATAWBA NUCLEAR STATION j
PRIORITY 1.ICENSE AMENDMENT LISTING AMENDMENTS WITfl SIGNIFICANT MILESTONES AFFECTED SUBMITTAL DESIRED il -
DESCRIPTION TECH SPEC DATE DATE REMARKS
- 01 FULLY WITlIDRAWN ROD BANK F3.1-1 11/10/89 03/01/90' CilANGE ADDRESSES CONTROL INSERTION LIMIT CHANGED (U1EOC4)
ROD WEAR CONCERNS.
FROM 228 TO 225 STEPS. - C11ANGE REDUCES MINIMUM ND 4.9.8.1 04/06/89 03/01/90 REDUCED ND FLOW INCREASES FLOW RENIFED TO 1000 GPM 4.9.8.2 09/06/89 (U1E004)
MARGIN AGAINST VORTEXING WHEN NC Is PARTIALLY DRAIN-(GL 89-17). NC TEMPERATURE ED. SURVEILLANCE ADDED TO BELOW 140 F MINIMIZES BO-ENSURE NC T. BELOW 140 F.
RON DILUTION ACCIDENT.
03 HEATUP.AND C00LDOWN CURVES 3.4.9.1 04/19/89 03/01/90 09/13 SUBMITTAL CORRECTED
-REVISED TO REFLECT UNIT 2 F3.4-2 09/13/89 (U1EOC4)
ERROR IN WESTING 110USE WCAP.
CAPSULE WITHDRAWAL ANALYSIS F3.4-3 AND RG 1.99, REVISION 2.
T4.4-3 CAPSULE = WITHDRAWAL SCIIEDULE BEING UPDATED. INCONEL CLADDED CONTROL ROD 5.3.2 TO BE 06/15/90 CHANGE ADDRESSES REMOVAL OF TO BE REMOVED FROM CORE.
SUBMITTED (U2EOC3)
EXPERIMENTAL RCCA. TO BE SUBMITTED TO NRC 01/12/90.
~05 TABLES 3.6-1 AND 3.6-2',
1.7 TO BE 06/15/90 ADDITIONAL PENETRATIONS RE-
' CONTAINMENT ISOLATION VAL-3/4.6.1 SUBMITTED (U2EOC3)
QUIRED TO SUPPORT AIRLOCK VES,-TO BE RELOCATED TO 3/4.6.2 MODIFICATION. RELOCATION OF YSAR SELECTED LICENSE COM-T3.6-1 TABLES TO FSAR WILL ALLOW MITMENT-(SLC) MANUAL. TABLE T3.6-2 EVALUATION OF FUTURE CHAN-3.6-2 REVISED TO REFLECT GES PURSUANT TO 10CFR50.59.
PENETRATIONS TO BE ADDED DURING U2EOC3 OUTAGE.
c
.i
,a I;
ATTACllMENT II (Page 1 of 3)
CATAWBA NUCLEAR STATION PRIORITY LICENSE AMENIMEKr LISTING AMENDMENTS WHICH SIGNIFICANTLY IMPROVE OPERATIONS OR CIARIFY EXISTING SPECIFICATIONS AFFECTED SUBMITTAL DESIRED DESCRIPTION TECll SPEC DATE DATE REMARKS 01 CHANGE SPECIFIES CA SUR.
4.7.1.2.1 02/15/88 04/01/90 CllANGE INCREASES AVAILABI-VEILLANCE APPLIES ONLY LITY OF CA.
TO DISCHARGE PATil, u
02 ' TECH SPECS REVISED TO RE-T 3.3-3 07/25/88 04/27/90 CHANGE CLARIFIES TECH SPEC FLECT TERMINATION AND T 3.3-4 05/27/88 REQUIREMENTS TO OPERATORS.
START PERMISSIVES FOR CPCS.
T 3.3-5 ACTION STATEMENT ADDED FOR T 4.3-2 CPCS TO PLACE INOPERABLE 4.6.2 CllANNEL IN SAFE MODE AND 4.6.5
I l
. 03 EMERGENCY POWER SOURCE RE-3/4.7.6.1 06/26/88 05/26/90 COMMITMENT TO CHANGE TS QUIREMENTS TO BE SPECIFIED 3/4.7.6.2 MADE ON RESPONSE TO VIO FOR MODES 1-4. NEW TS AD-B3/4.7.6 414/87-44-03. CHANGE RE.
.1 DRESSES VC REQUIREMENTS FOR MOVES AMBIGUITY FROM TS.
i MODES 5-6. SURVEILLANCE RE-QUIREMENT TO BE PERFORMED ON A PER TRAIN BASIS.
{
i f
l l
l I.
l'
C
~.
s ATTACHMENT II (Page 2 of 3)
CATAWBA NUCLEAR STATION PRIORITY LICENSE AMENDMIOff LISTING AMENDM10frS WHICH SIGNIFICA)frLY IMPROVE OPERATIONS OR CLARIFY EXISTING SPECIFICATIONS AFFECTED SUBMITTAL DESIRED DESCRIPTION TECH SPEC DATE DATE REMARKS
-04 INCREASED CARBON ADSORBER 4.7.6 12/21/87 06/01/90 EXISTING SAMPLING INTERVAL SURVEILLANCE INTERVAL FROM 06/14/89 IS OVERLY RESTRICTIVE.
720 TO 1440 HOURS OF.0PER-ATION. UNIT 1 BYPASS LEAK-AGE /METHIL IODIDE LIMITS CHANGED TO MATCH UNIT 2.
05 ELECTROLYTE LEVEL REQUIRE-4.7.13 06/15/89 06/15/90 C0dMITMENT TO CHANGE TS MENT AND OVERALL SSF BATTERY MADE ON RESPONSE TO VIO
/ INDIVIDUAL CELL VOLTAGE 413,414/88-33.
INSPECTION CHANGED TO AGREE WITH ANSI STANDARD. SPECIFIC GRAVITY CIIECK BEING DELETED.
06 ESF INSTRUMENTATION TABLE T3.3-3 03/11/88 07/15/90 EXISTING TS UNCLEAR AS TO TO CORRECTLY LIST TOTAL No.
WilICH PUMP (MDCAP OR MFWP)-
0F CHANNELS, CllANNELS TO IS BEING REFERRED TO.
TRIP, AND HINIMUM OPERABLE CHANNELS FOR AUTO START OF MDCAPs ON TRIP OF ALL MFWPs.
07 AUXILIARY SilUTDOWN CONTROL T3.9-9 03/11/88 08/11/90 ASP AND CA PUMP TURBINE PANEL READOUTS FOR S/G PRES-CONTROL PANEL PROVIDE SURE AND LEVEL AND CA FLOW SAME INFORMATION AT TWO RATE ADDED TO TS.
DIFFERENT LOCATIONS. BOTH READOUTS S110ULD BE LISTED.
08 NW VALVE SEAL INJECTION RE-4.6.6.1 10/31/89 09/31/90 SURVEILLANCE UPDATED TO QUIREMENTS REPLACED BY MIN-4.6.6.2 REFLECT ONE PUMP RN RE-NIMUM PRESSURE REQUIREMENT.
ANALYSIS AND CORRECT ERROR LO-LO NW SURGE TANK PRES-IN ORIGINAL NW SURGE TANK SURE INCREASED TO 36.4 PSIG.
PRESSURE CALCULATION.
V:
i-c '
ATTACilMFN1' II (Page 3 of 3)
CATAWBA N11 CLEAR STATION PRIORITY LICENSE AMENDMEE LISTING AMENDMENTS WHICH SIGNIFICAMIN IMPROVE OPERATIONS OR CLARIFY EXISTING SPECIFICATIONS-l U
AFFECTED SUBMITTAL DESIRED 1!
DESCRIPTION TECil SPEC DATE DATE REMARKS 4,m 09
~ TilIS CHANGE 1) DELETES STA--
4.9.4.1 10/25/89 10/25/90 TS CilANGE REQUESTED IN TEMENT CONCERNING IIR ISO-4.9.4.2 RESPONSE TO LER 413/89-09 LATION ON llEATER FAILURE; 4.9.4.3 COMMITMENT.
- 2) CLARIFIES UPPER / LOWER
' CONTAINMENT VP. OPERABILITY; AND 3) ADDS IIR SURVEILLAN-CES.
i
' '; s r V~
.ATTACilMENT III (Page 1 of'1)
CATAWBA NUCLEAR STATION PRIORITY LICENSE AMENDMENT LISTING BALANCE OF AMENDMElfl'S SUBMITTED TO NRC i
AFFECTED SUBMITTAL DESIRED Il DESCRIPTION ~
TECil SPEC DATE DATE REMARKS
-01 EDITORIAL CHANGES CORRECT MULTIPLE 10/28/87 08/01/90 ADMINISTRATIVE CllANGE.
TYPOGRAPilICAL ERRORS, UP-LOCATIONS DATE-INFORMATION,-OR-CIARIFY INFORMATION.
02 DELETE CA,~CF, BW, AND BB T3.6.1 01/16/89 05/01/90 TilESE VALVES DO NOT SERVE VALVES:FROM TABLE 3.6-2.
T3.6.2 A TRUE CONTAINMENT ISOLA-TION FUNCTION. tHIS CHANGE 4
WILL BE WITHDRAWN FOLLOWING SUBMITTAL OF CHANGE TO RELOCATE TABLES TO TIIE SLC MANUAL.
h
s A'ITACHMENT IV (Page 1 of 2)
CATAWBA NUCLEAR STATION 4
PRIORITY LICENSE AMENDMENT LISTING AMENDMENTS UNDER DEVELOPMENT AND EXPECTED SUBMI'1"fAL DATES i
AFFECTED SUBMITTAL DESIRED
-Il DESCRIPTION
-TECH SPEC DATE DATE REMARKS 01
- CYCLE SPECIFIC VARIABLES ALL 01/12/90 07/15/90 ELIMINATES RELOAD SUBMIT-RELOCATED FROM TS TO CORE CYCLE TALS. BEING PURSUED JOINTLY OPERATING LIMITS REPORT SPECIFIC FOR MNS/CNS.
j (COLR).
VARIABLES l
02 CHANGE RELOCATES RADIOLOG-ALL RETS 01/12/90 08/15/90 GL 89-01 IDENTIFIES RETS RE '
ICAL EFFLUENT TS (RETS) TO LOCATION AS LINE-ITEM TS'IN-SLC MANUAL, PCP, AND ODCM PROVEMENT. REQUEST WILL BE MANUAL.
EXPEDITIOUSLY APPROVED BY NRC. SLC MANUAL TO BE IMPLEMENTED BY 12/15/89.
03 FIRE PROTECTION REQUIRE ALL FIRE 02/15/90 09/15/90 GL 88-12 IDENTIFIES AS TS MENTS' RELOCATED TO SLC.
PROTECTION IMPROVEMENT ITEM. REQUEST MANUAL.
WILL BE APPROVED EXPEDIT-R IOUSLY BY NRC.
04 VC/YC BASIS TO BE UPDATED B3/4.7.6 02/30/90 10/30/90 NONE TO REFLECT ACTUAL SYSTEM CONFIGURATION.
05 BORIC ACID TANK MINIMUM 3.1.2.5 12/15/89 12/30/90 CHANGE REVISES TANK LEVELS VOLUME INCREASED TO 12,000 DUE TO THE REVIEW OF UN-GALLONS. RWST MINIMUM USABLE VOLUMES.
' VOLUME INCREASED TO 45,000 GALLONS.
1 06 SNSWP AVERAGE TEMPERATURE 3.7.5 02/15/90 01/15/91 FSAR SAFETY ANALYSIS REMAINS MONITORING ELEVATION IN-B3.7.5 BOUNDING. TS CHANGE IDENT-CREASED FROM 540' TO 557'.
IFIED ON LER 413/89-14.
- TS. BASES UPDATED TO RE-FLECT DESIGN BASIS ANALY-SIS TEMPERATURE ASSUMPTIONS.
3 g
ATTACHMENT IV (Page 2 of 2)
CATAWRA, NUCLEAR STATION PRIORITY LICENSE AMENDMENT LISTING AMENDMENTS UNDER DEVEIDPMENT AND EXPECTED SUBMITTAL DATES AFFECTED SUBMITTAL DESIRED
- Il DESCRIPTION TECil SPEC DATE DATE REMARKS
- 07. INCREASE FWST BORON CONCEN-3.5.5.b 03/15/90 02/15/91 2100 PPM LIMIT IS AN OPER-TRATION UPPER LIMIT FROM ATIONAL BURDEN. CilANGE MAY 2100 TO 2200 PPM.
REDUCE FORCED SIIUTDOWNS.
08 SURVEILLANCE REQUIREMENT 4.6.1.8 03/15/90 02/30/91 SURVEILLANCE ENSURES VE TO BE MODIFIED TO ACCOUNT B3.6.1.8 SYSTEM CAPABLE TO PULL FOR PRESSURE DIFFERENCE
-0.5 INCil WATER PRESSURE
..BETWEEN UPPER AND LOWER AT TEMPERATURE OF -5 F.
CONTAINMENT.
- 09 D/G FUEL OIL STORAGE TANK 3.8.1.1 03/15/90-03/08/91 FUEL REQUIREMENT TO RUN D/G
-MINIMUM LEVEL REDUCED TO FOR 7 DAYS IS LESS TilAN 73,100 GALLONS.
MINIMUM ALLOWABLE TS LEVEL.
10 FUSE TESTING REQUIREMENTS 4.8.4.2 04/10/90 03/10/91 NONE MODIFIED TO CONFORM TO IEEE 4.8.4.3 STANDARD. DESCRIPTION OF LOW-B3/4.8.4 ER VOLTAGE CIRCUIT BREAKER TESTING MET 110D RELOCATED TO BASES.
11 DELETE REQUIREMENT TilAT 4.0.2 04/15/90 04/15/91 GL 89-14 IDENTIFIES AS TS ANY 3 CONSEQUTIVE SURVE-IMPROVEMENT ITEM. REQUEST ILLANCES-CANNOT EXCEED WILL BE APPROVED EXPEDIT-3.25 X 1 SURVEILLANCE IOUSLY BY NRC.
INTERVAL.
hw.
3
-.g ATTACHMENT V (Page 1 of 1)
CATAWBA NUClJAR STATION INSERVICE INSPECTION PIAN RELIFJ REQUESTS SUBMITTAL DESIRED DESCRIPTION DATE DATE REMARKS
.=
89 : RELIEF REQUEST FOR INSPECTION 01/30/89 01/31/90 SURFACE EXAMINATION CANNOT BE-OF CERTAIN WELDS ON MAIN PERFORMED DUE TO GUARD PIPE SYSTEM LINES.
COVERING CIRCUMFERENTIAL WELDS.'
l-l l~
1 l
k