(Q.
s ATTACHMENT 2 Accident Monitoring Instrumentation Limiting Condition For Operation 3.3.3.8 The accident monitoring instrumentation channels shown in Table 3.3-11 shall be OPERABLE.
APPLICABILITY: MODES 1, 2 and 3.
ACTION:
a.
With the number of OPERABLc accident monitoring channels less than the required number of channels shown in Table 3.3-11, either restore the inoperable channel to OPERABLE status within 31 days, or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
b.
With the number of OPERABLE accident monitoring channels less than the minimum channels OPERABLE requirements of Table 3.3-11; either restore the inoperable channels to OPERABLE status within 7 days or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
SURVEILLANCE REQUIREMENTS 4.3.3.8 Each accident monitoring instrumentation sSannel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK and CHANNEL CALIBRATION operations at the frequencies shown in Table 4.3-7.
8 0 090 40 'a E l
i TABLE 3.3-11 ACCIDENT HONITORING INSTRUMENTATION REQUIRED MINIMUM NUMBER CHANNELS INSTRUMENT OF CHANNELS OPERABLE 1.
Reactor Coolant Outlet Temperature-T
-Wide Range 2
2 ilot 2.
Reactor Coolant Inlet Temperature-TCold-Wide Range 2
2 3.
Reactor Coolant Pressure-Wide Range 2
2 4.
Steam Generator Water Level-Wide Range or Narrow Range 2 / Steam Generator 1 of 2/ Steam Generator.
5.
Refueling Water 5torage Tank Water Level 2
2 6.
Containment Pressure 2
2 7.
Pressurizer Water Level 2
2 8.
Steam Line Pressure 2 / Steam Generator 2/ Steam Generator 9.
Auxiliary Feedwater Flow Rate 2
2
- 10. Reactor Coolant System Subcooling Margin Monitor 2
2 1 / Valve 1/ Valve
- 11. PORY Position Indicator
- 1 / Valve 1/ Valve
- 12. PORV Block Valve Position Indicator **
i
- 13. Safety Valve Position Indicator 1 / Valve 1/ Valve
- - Not applicable if associated block valve is in the closed position.
- -- Not applicable if the block valve is verified in the closed position and power is removed.
e i
b
TABLE 4.3-7 ACCIDENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CilANNEL CHANNEL INSTRUMENT, CHECK CALIBRATION M
R 1.
Reactor Coolant Outlet Temperature-THo t-2.
Reactor Coolant Temperature-TCold-Wide Range M
R 3.
Reactor Coolant Pressure-Wide Range M
R 4.
Steam Generator Water Level-Wide Range or M
R harrow Range 5.
Refueling Water Storage Tank Water Level M
R 6.
Containment Pressure M
R 7.
Pressurizer Water Level M
R 8.
Steam Line Pressure M
R 9.
Auxiliary Feedwater Flow Rate M
R
- 10. Reactor Coolant System Subcooling M
R Margin Monitor
- 11. PORY Position Indicator
- M R
12.
PORV Block Valve Position Indicator **
M R
13.
Safety Valve Position Indicator M
R Not applicable if associated block valve is in the closed position.
Not applicable if block valved verified ir, closed position and power removed.