ML19310F787

From kanterella
Jump to navigation Jump to search
Submits Final Response to IE Bulletin 79-03A, Longitudinal Weld Defects in ASME SA-312,Type 304 Stainless Steel Pipe. Addl Specified Matls Are Not Used Where Design Hoop Stresses Exceed 85% Code Criteria
ML19310F787
Person / Time
Site: Wolf Creek, Callaway  Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 01/26/1981
From: Seiken S
STANDARDIZED NUCLEAR UNIT POWER PLANT SYSTEM
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
81-004, 81-4, IEB-79-03A, IEB-79-3A, NUDOCS 8102240070
Download: ML19310F787 (1)


Text

TEC SN UPPS standard red Nclear Umt Power Mant Sv stem

)

5 Chae Cherry Rt id nome. uugend x *+

SLNRC 81- 004 FILE: 0278.10

'3""'

SUBJ:

NRC/IE Bullet in 79-03A: Longitudinal heid Def ects in ASME SA-312, Type 304

~~S_tyinless Steel Pipe Mr. Boyce Grier Director, Regian I

.,+hN Office of Inspection and Enforcement

/QF G4 U.S. Nuclear Regulatory Ccmission I?/, g \\J *

'?N i!C 'd 631 Park Avenue QN bl % *

'O Yi King of Prussia, Per:nsylvania 19406 4 E3T " 7 9

.r Docket Nos.

STN 50-482, STN 50-483, STN 50-486 j

w ou A u 5%vv*

fy/

\\p,A Ref: a) SLNRC 80-52 dtd. II/26/E0: Subj. as Above s.

q s

b) SLNRC S0-38 dtd. 8/20/80:

1' n

/sY

'D

Dear Mr. Grier:

The reference letters provided interim responses to IE Bulletin 79-03A concerning the use or potential use of f usion-welded SA-312 Type 304 stainless steel pipe in Callaway 1 and Wolf Creek units. These responses indicated that fusion welded materials of the type described in the sub-ject bulletin have not been used in piping systems or components fur-nished by the Lead A/E in which tne design hoop stresses equal or exceed 25 percent of ASME allowchle.

Data concerning the use of these materials in nonpiping components furnished by the NSSS supplier and in replacement piping purchased directly by the Wolf Creek constructor were under exam-ination at the time of the most recent, Ref. a) update.

Since that time, we have completed our investigation and are able to report that none of these additional materials are either in use or scheduled for use in systers or ccmponents in which design hoop stresses equal or exceed the 85 percent code criteria.

If you have further questions in this matter, please contact the under-signed.

Very truly yours, S.

. Seiken QA Manager SJ5:dck:5a29 cc:

Mr. J. A. Keppler, Dire-tor, Region III USNRC

'Mr. W. Wescott, Region III, USNRC Mr. Karl Se3 rit, Director, Region I'v, USNRC f

Mr. Victor Stello, Jr., Director, Office of Inspection and Enf orcenent, USNRC, Washington, D.C.

T.

Vance!, Wolf Creek :'esident Inspector, USN?C h

J.* *. ; a n _

,10224( d

.s w - e c, r,112. 2 v p x i e t,t Insoector. USNRC