ML19296C726
| ML19296C726 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 10/21/2019 |
| From: | Southern Nuclear Operating Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19296D008 | List:
|
| References | |
| NL-19-1193 | |
| Download: ML19296C726 (23) | |
Text
REV 14 10/07 OPERATING BASIS EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 258 FT 0 IN.
FIGURE 3D-18
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 323 FT 0 IN.
FIGURE 3D-19
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 323 FT 0 IN.
FIGURE 3D-20
REV 14 10/07 OPERATING BASIS EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 323 FT 0 IN.
FIGURE 3D-21
REV 14 10/07 OPERATING BASIS EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 323 FT 0 IN.
FIGURE 3D-22
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 400 FT 0 IN.
FIGURE 3D-23
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 400 FT 0 IN.
FIGURE 3D-24
REV 14 10/07 OPERATING BASIS EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 400 FT 0 IN.
FIGURE 3D-25
REV 14 10/07 OPERATING BASIS EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 400 FT 0 IN.
FIGURE 3D-26
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 180 FT 0 IN.
FIGURE 3D-27
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 180 FT 0 IN.
FIGURE 3D-28
REV 14 10/07 OPERATING BASIS EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 180 FT 0 IN.
FIGURE 3D-29
REV 14 10/07 OPERATING BASIS EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 180 FT 0 IN.
FIGURE 3D-30
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 220 FT 0 IN.
FIGURE 3D-31
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 220 FT 0 IN.
FIGURE 3D-32
REV 14 10/07 OPERATING BASIS EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 220 FT 0 IN.
FIGURE 3D-33
REV 14 10/07 OPERATING BASIS EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 220 FT 0 IN.
FIGURE 3D-34
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 260 FT 0 IN.
FIGURE 3D-35
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 260 FT 0 IN.
FIGURE 3D-36
REV 14 10/07 OPERATING BASIS EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 260 FT 0 IN.
FIGURE 3D-37
REV 14 10/07 OPERATING BASIS EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 260 FT 0 IN.
FIGURE 3D-38
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE HORIZ. ACCEL. RESPONSE SPECTRA EL. 143 FT 6 IN.
FIGURE 3D-39
REV 14 10/07 SAFE SHUTDOWN EARTHQUAKE VERTICAL ACCEL. RESPONSE SPECTRA EL. 143 FT 6 IN.
FIGURE 3D-40