REGULATORY DOCKET FILE COPY INSERVICE INSPECTION PROGRAM REFUELING OUTAGE NO. 2 SURRY POWER STATION UNIT NO. 1 DECEMBER 30, 1975 REPORT NO. ISI 75-8 DOCKET NO. 50-280 LICENSE NO. DPR-32 Vepco VIRGINIA ELECTRIC AND POWER COMPANY

I I

I I

I

.I I

I.

I I

I I

I

-1 I

I I

I I

INSERVICE INSPECTION PROGRAM REFUELING OUTAGE NO. *2 SURRY POWER STATION UNIT NO. 1 DECEMBER 30, 1975 REPORT NO. !SI 75-8 DOCKET NO. 50-280

_LICENSE NO. DPR-32 Vepco VIRGINIA ELECTRIC AND POWER COMPANY

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I.

INTRODUCTION In accordance with the requirements of Technical Specification 6.6.C, this report summarizes the results of the inservice inspection activities performed during Refueling Outage No. 2 of Unit No. 1 at the Surry Power Station.

The document entitled Inservice Inspection Program, Refueling Outage No. 2, Unit No. 1, Surry* Power Station, Report No. !SI 75-4 dated July 1975 provides-the specific details concerning the inspections which were scheduled to be performed.

The inservice inspections were conducted by Virginia Electric and Power Company (Vepco) representatives.

The areas inspected by Vepco personnel are detailed below:.

Com~onent Low Head Safety Injection System Piping Tech Spec Refer.

7.2 Area Inspected Piping in valve pit Method of Inspection VT II.

INSPECTION

SUMMARY

Inservice inspections-:for Unit No. 1, Refueling Outage No. 2, were con-ducted in accordance with Inservice Inspection Repqrt IS! 75-4.

The low h~ad* safety injection system piping located in the valve pit was visually inspected during the period November 4-9, 1975.

In addition to the inspectiqns required by the Technical Specifications, eddy current examinations of the steam generator tubes were conducted.

The results of these inspections are reported herein.

I I

I I

I I

I I

I I

I I

I I

I I

I I

I III. INSPECTION RESULTS The visual inspection of the low head safety injection system piping in the valve pit indicated satisfactory results.

Many of the previously reported arc* strikes had been removed.

Visual indications of minor rusting and corrosion were noted.

Leaky packings and gaskets were repaired to eliminate sources of leakage *

. Extensive examinations of the steam generators were*conducted to sat-isfy the requirements of Regulatory Guide 1.83.and to obtain additional data on the generic tube diameter reduction phenomenon,. i.e. denting.

In ad-dition to eddy current testing of the tubes, a visual inspection of the U-bend region of one steam generator was conducted.

Additional visual in-spections of the tupes and tube support plates were conducted through hand holes on all.three steam generators and on "hillside" ports on A steam generator.

The eddy current testing showed that all* inspected tubes on both the hot and cold leg sides exhibit some local diameter reduction at most sup-port plates.

The extent of this deformation is mostly in the range of less than 20 mils reduction in diameter, but some signals indicate as much as approximately 50 mils reduction in diameter.

Deformation tended to be greatest.in those rows closest to the divider lane (rows 1 through 3) where gauging of the leaking tubes indicated an inside diameter reduction to 0.550 inch (at the second support plate).

No significant differences be-tween the hot and cold legs were noted.

Visual inspection of the U-bend region and top of the tube bundle of C steam generator revealed no unusual conditions near the anti-vibration bars (AVB's) such as shifting, visible corrosion, or tube damage.

There I

I I

I I

I I

I I

I I

I I

I I

I I

I I

was a hard deposit noted at the intersection of the AVB's and the tubes.

There was no apparent shifting of the uppermost (7th) tube support plate, with normal clearance between the support plate and wrapper evident.* The spaces between the tubes and the tube support plates appeared to be filled with a deposit as no visible gaps were apparent.

The tube bundle appeared to be in its as-built condition with no.visible* bending, bowing, or mis-alignment of tubes in the U-bend region.

Additional visual inspections through hand holes of A, Band C steam generators were conducted.

In-plane "hour-glassing" or the rectangular flow slots in the support plates in all three steam generators was noted with the least amount occurring in steam generator B. No signs of abnormal surface sca~e, deformation, cracks, or out of plane distortion were evident.**

Deposits were evident in the spaces between the tubes and tube support plates with no clearance between the tube and tube supports indicated.

Looking down the divider lane, the tubes appear straight from the top of the tube sheet to approximately 15 to 20 inches below the first support plate with gradual bowing from there to follow the _!:ontour of* "hour-glassing" in the support plate flow slots.

Uniform spacing was observed between adjacent columns of tubes.

A summary of the inspection conducted on each steam generator is given below.

A STEAM GENERATOR A total of 1583 tubes were checked at 400 KHZ in the inlet side of which 102 tubes were in the low flow area.

These tubes were checked up to and past the 7th tube support on the inlet side and into the U-bend.

All remaining tubes were checked past the 2nd tube support.

Of the total,

~--------------------

I I

I I

I I

I I

1*

I I

I I

I I

I I

I I

1477 had indications of tube defects.

A breakdown of the indications are as follows: 1185 tubes ~20% defect, 69 tubes 20-29%, 51 tubes 30-39%, 133 tubes 40-49%, and 39 tubes.::_50%.

After completing the 400 KHZ tests for defects, 486 additional tubes were inspected in the inlet side and 210 tubes were inspected in the out-let side.

The tes~s were performed *at 400 KHZ with a.700 inch diameter probe and a.540 inch diameter probe to determine the extent of denting in the steam generator.

Of those tubes tested, a.540,inch diameter probe would not reach the U-bend area in 36 tubes on the inlet side and 31 tubes on the outlet side.

There are a total of 297 tubes (8.8%) plugged in "A" steam generator.

B STEAM GENERATOR A total of 609 tubes were inspected in steam generator "B" inlet at 400 KHZ of which 71 tubes were in the low flow area.

  • These tubes were checked up to and past the 7th tube supp.ort on the inlet side, and into the U-bend.

All remaining tubes were checked past the 2nd tube support on the inlet side.

There,W'ere 76 indications in "B" inlet.

A breakdown of the indications are as follows:

35 tubes <20% defect, 18 tubes 20-29%, 21 tubes 30-39%, 2 tubes 40-49%.

Four (4) tubes were explosively plugged in "B" generator.

Two (2) of those tubes were found on this inspection to be 40% and two* (2) additional tubes were plugged because of arc strike*s on. the secondary side.

An additional 168 tubes were inspected in "B" steam generator for denting.

All tubes inspected would pass a.700 inch diameter probe past the 7th support and into the U-bend area.

There are a total of 8 tubes (0.2%) plugged in "B" steam generator.

I I

I I

I I

I I

I I

I I

I I

I I

I I

I C STEAM GENERATOR A total of 616-tubes were inspected in steam generator "C" inlet at. 400 KHZ of which 88 tubes were in the low flow area.

These 88 tubes were checked past the 7th tube support on the inlet side and into the U-bend.

All the remaining tubes were checked past the 2nd tube support on the inlet side.

Of the tubes inspected there were 174 -indications of tube defects.

There were 8 tubes <20% defect, 14 tub~s 20-29%, 43 tubes 30-39%; 54 tubes 40-49% and 55 tubes >50%.

Because of defects, 115 tubes were explosively plugged in "C" steam generator.

109 of those tubes were found on this inspection to be >40%

defective.

Six additional tubes were plugged that had indications <40%.

IV.

CONCLUSIONS The results of the inservice inspectidns performed on the low head safety injection system piping verified the integrity of the systems and components examined and satisfied the requ-ireni.ents of the Technical Speci-fications.

The discrepancies noted were corrected.

Based on the results of the inservice inspection program, as summarized herein, the low head safety 1njection system piping inspected has not experienced degradation and there is reasonable assurance that it will continue to perform*its design function in a safe and satisfactory manner.

The eddy current inspections of the steam generators indicate that there is significant denting occurring.

Inspections of other Westinghouse steam generators indicate that denting is a* generic concern.

The.evaluation and tentative conclusions as to the nature of this phenomenon are, nec-essarily, preliminary and are based upon currently available information, I

I I

I I

I I

I I

I I

I I

I I

I I

I I

including the information presented herein and data obtained from other facilities.

Additional data is required to substantiate, or possibly modify, the postulated mechanism for tube deformation.

The current postulate to account for denting which best satisfies the physical evidence is as follows:

A substance fills the gap between the tube and tube support plate hole, denting the tube and dilating the hole (mainly through stretching of the ligaments which surround the tube hole).

The pressure neces,saryto stretch the ligaments is approximately 6,000 to 7,000 psi.

As every tube hole dilates, the entire projected area of the tube support plate increases.

At rigid regions of the support plate, the in-plane displacement of the plate is locally constrained resulting in 1.'hard spo:ts" which do not contain the array* of interstitial flow holes found elsewhere in the support plate.

The effect of constraint at the "hard spots" is to concentrate the deformation of tubes, tube holes, interstitial flow holes and flow ports (located at the center of the tube bundle).

The de-formation of the tubes observed at- "hard spots" is more extensive arid of greater magnitude than it is elsewhere in the support plate.

Immediately after the discovery of local tube deformations in the area of the tube support plates, an extensive analytical and experimental in-vestigation was started by Westinghouse and supported by the utilities.

These analyses were based on several mechanisms, all of which were believed to locally reduce the outside diameter of the tube.

Of these mechanisms, the two most probable were thermal ratcheting and crud deposition~

The thermal ratcheting was assumed to occur with an internal to external pres-sure difference of 1500 psi and an alternating tube OD temperature from approximately 590 degrees to 490 degrees.

This.mechanism alone, however, was shown not to be credible both experimentally and analytically.

The I

I I

I I

I I

,I I

I I

'I I

I I

I I

I I

I I

crud deposition model, however, did show credibility in that significant deformation could be obtained in relatively few cycles.

The crud deposit in the tube to tube support hole annulus was assumed to be incompressible and with a zero coefficient of thermal expansion would continue to fill the gap after each cycle.

The total radial deformation of each cycle was 1.7 x 10-r+ inch.

This or a similar mechanism will result in a net pressure on the tube outside diameter and the tube hole inside diameter.

Determination of*Externai Pressure to Yie"id Tube and Support Plate The tube AP can be approximated with the following relationship:

AP= (Yield Strength)

Mean Radius

+ 1.

Wall Thickness 2

AP= (44,660)

= 4620 psi

.4125 + 1

.045 2

This pressure difference will cause yielding and a permanent deformation of the tube.

With the internal (reactor coolant) pressure at 2,235 psi, the outer pressure for a AP of 4,620 is 6,855 psi.

The 6,855 psi represents the total "hydrostatic" pressure acting on.the OD surface of. the tube and would include the possible effect of secondary side pressure.

When 6,855 psi is considered to*be applied to the outside of the tube, it is also applied to the ID surface of the hole in the support plate under the assumptions that the crevice is filled with an incompressible substance.

The stress across the minimum width membrane in the support plate is calculated to be 35,718 psi, this is greater than the ASME code value at 500 degrees F for the support plate material of 24,500 psi.

Therefore, the tube support plate will receive a permanent distortion.

Actual in-plane distortion of the tube support plates has been observed which tends to support the latter hypotheses.

I I

I I

I I

I I

I I

I I

I I

I I

I I

I Mechanical tests are being run to simulate severely deformed tubes and to evaluate the hydrostatic collapse characteristics *of tubes with given configurations of deformation which are representative of. tube con-ditions observed in steam generators on Surry Unit No. 1.

The deformation of tubes and support plates observed to date is believed to be the result of the growth of deposits and/or corrosion product within the support plate in those steam generators which have operated for extended periods on*phosphate water chemistry and more recently on all v6latile treat-ment (AVT).

A substance accumulates in the annular gap between tube and support plate hole.

The substance exerts force directed radially inward on the tube and outward on the support plate when the gap is filled.

The re-sult is a reduction of tube diameter and an increase of support plate hole diameter.

At rigid* areas of the support plate, the deformation is most extensive and least symmetrical (about. the axis of the tube and of the.hole).

Based on all the information on the tube diameter reduction phenomenon available at this time, summaries of which have been presented above, the following conclusions have been reached:

1.
2.
3.

The phenomenon appears to be restricted to units which had extensive operation with phosphate treatment prior to con-version to AVT.

The phenomenon is hypothesized to be caused by a build up of a corrosion product in the space between the tube and the tube support plate.

There is no apparent change in the mechanical properties of the tube metal.

Data from tests performed on tubes removed from steam generators indicate properties (e.g.

ductility) which are typical of new tube material.

I I

I I

I I

I I

  • I I

I I

I

'I I

I I

I I

4.
5.

Station operation can continue safely while further evaluation and investigation of the phenomenon proceeds.

Vepco, in conjunction with the Westinghouse Electr.ic Corporation, will continue to investigate the matter.

Additional eddy current examinations are scheduled during forthcoming refueling outages.

The reader is referred. to the documents listed in Section V for more specific details.

V.

REFERENCES*

1.
2.
4.

Report of Inservice Inspection Conducted by Vepco Personnel, Refueling Outage No. 2, Unit No. 1, Surry Power Station, December *30, 1975, Virginia Electric and Power Company.

Inservice Inspection Program, Refueling Outage No. 2, Unit No. l, ISI 75-4, July 1975, Virginia Electric and Power Company.

Section 4.2, Technical.Specifica1=ions, Surry Power Station, Unit Nos. 1 and 2, Virginia Electric and Power Company.

Letter to Dr. Robert E. Heineman, Director, Division of Safety Systems, U.S. Nuclear Regulatory Commission, dated December 18, 1975, NS-CE-871,' from C. Ercheldinger, Westinghouse Electric Corporation (Non-proprietary).