ML19003A324

From kanterella
Jump to navigation Jump to search
To Integrated Final Safety Analysis Report, Chapter 2, Section 2.4.12, Figures 226-247
ML19003A324
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 12/21/2018
From:
Florida Power & Light Co
To:
Office of New Reactors
Shared Package
ML19003A318 List: ... further results
References
L-2018-237
Download: ML19003A324 (35)


Text

2.4.12-118 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-226 Biscayne Aquifer Potentiometric Surface Map, Lower Monitoring Interval, October 5, 2008 (Sheet 1 of 2) High Tide

2.4.12-119 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-226 Biscayne Aquifer Potentiometric Surface Map, Lower Monitoring Interval, October 5, 2008 (Sheet 2 of 2) Low Tide

2.4.12-120 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-227 Biscayne Aquifer Potentiometric Surface Map, Upper Monitoring Interval, January 20-21, 2009 (Sheet 1 of 2) High Tide

2.4.12-121 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-227 Biscayne Aquifer Potentiometric Surface Map, Upper Monitoring Interval, January 20-21, 2009 (Sheet 2 of 2) Low Tide

2.4.12-122 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-228 Biscayne Aquifer Potentiometric Surface Map, Lower Monitoring Interval, January 20-21, 2009 (Sheet 1 of 2) High Tide

2.4.12-123 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-228 Biscayne Aquifer Potentiometric Surface Map, Lower Monitoring Interval, January 20-21, 2009 (Sheet 2 of 2) Low Tide

2.4.12-124 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 215 Figure 2.4.12-229 May 1980 Upper Floridan Aquifer Potentiometric Surface Map

2.4.12-125 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-230 Observation Wells and Surface Water Monitoring Locations in the Turkey Point Vicinity

2.4.12-126 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 232 Figure 2.4.12-231 Hydrographs of U.S. Geological Survey Wells in the Biscayne Aquifer

-1 0

1 2

3 4

5 6

7 1/1/1973 1/1/1977 1/1/1981 1/1/1985 1/1/1989 1/1/1993 1/1/1997 1/1/2001 1/1/2005 1/1/2009 G-1183 5 mi northwest of site Maximum daily level

-1 0

1 2

3 4

5 6

7 G-3356 6 mi west of site Maximum daily level

-1 0

1 2

3 4

5 6

7 G-3550 4 mi northwest of site Maximum daily level Ground surface = 3.1 feet MSL (NGVD 29)

Elevation (feet MSL)

-1 0

1 2

3 4

5 6

7 1/1/1973 1/1/1977 1/1/1981 1/1/1985 1/1/1989 1/1/1993 1/1/1997 1/1/2001 1/1/2005 1/1/2009 G-3549 4 mi north of site Maximum daily level Ground surface = 3.9 feet MSL (NGVD 29)

Ground surface = 6.6 feet MSL (NGVD 29)

Ground surface = 3.0 feet MSL (NGVD 29)

2.4.12-127 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 233 Figure 2.4.12-232 Hydrographs of South Florida Water Management District Well and Canal Levels and Precipitation 0

0.5 1

1.5 2

2.5 3

3.5 4

1/1/90 1/1/92 1/1/94 1/1/96 1/1/98 1/1/00 1/1/02 1/1/04 1/1/06 1/1/08 1/1/10 BBCW4 3 miles Northwest of site Mean Daily Elevation 0

0.5 1

1.5 2

2.5 3

3.5 4

1/1/90 1/1/92 1/1/94 1/1/96 1/1/98 1/1/00 1/1/02 1/1/04 1/1/06 1/1/08 1/1/10 S20 Canal Headwater 5 miles southwest of site Mean Daily Elevation 0

1 2

3 4

5 6

7 8

9 10 1/1/90 1/1/91 1/1/92 1/1/93 1/1/94 1/1/95 1/1/96 1/1/97 1/1/98 1/1/99 1/1/00 1/1/01 1/1/02 1/1/03 1/1/04 1/1/05 1/1/06 1/1/07 1/1/08 1/1/09 1/1/10 1/1/11 S20 Rain Gage 5 miles southwest of site No Record Elevation (feet MSL)

Precipitation (inches) 0 0.5 1

1.5 2

2.5 3

3.5 1/1/90 1/1/92 1/1/94 1/1/96 1/1/98 1/1/00 1/1/02 1/1/04 1/1/06 1/1/08 1/1/10 S20F Canal Headwater 3 miles northwest of site Mean Daily Elevation Ground surface = 2.8 feet MSL (NGVD 29)

2.4.12-128 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 1 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-606U OW-606L Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-129 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 2 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-621L OW-621U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-130 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 3 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-636L OW-636U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-131 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 4 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-706L OW-706U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-132 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 5 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-721L OW-721U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-133 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 6 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-735L OW-735U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-134 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 7 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-802L OW-802U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-135 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 8 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-805L OW-805U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-136 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 9 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-809L OW-809U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-137 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 10 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

OW-812L OW-812U Gaps in the time series plots indicate missing or rejected data The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-138 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-233 Hydrographs of Units 6 & 7 Biscayne Aquifer Observation Wells (Sheet 11 of 11)

-4.0

-3.5

-3.0

-2.5

-2.0

-1.5

-1.0

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 1-May-08 31-Jul-08 30-Oct-08 29-Jan-09 30-Apr-09 30-Jul-09 29-Oct-09 28-Jan-10 29-Apr-10 29-Jul-10 Date Elevation (ft NAVD 88)

SW-1 SW-2 Gaps in the time series plots indicate missing or rejected data SW-2 data are biased low approximately 0.2 ft The data represent observed water levels for the purpose of illustrating temporal trends.

2.4.12-139 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 234 Figure 2.4.12-234 Hydrograph of U.S. Geological Survey Well in the Upper Floridan Aquifer 30 32 34 36 38 40 42 44 1/1/1965 1/1/1969 1/1/1973 1/1/1977 1/1/1981 1/1/1985 1/1/1989 1/1/1993 1/1/1997 1/1/2001 1/1/2005 1/1/2009 Elevation (feet MSL)

NP-100 17 miles west of site Ground surface = 4.5 feet MSL (NGVD 29)

2.4.12-140 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-235 Regional Aquifer Test Locations

2.4.12-141 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 240 Figure 2.4.12-236 Biscayne Aquifer Regional Transmissivity

2.4.12-142 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Table 2.4.12-207 Figure 2.4.12-237 Formation Properties from Rock Core Testing Tamiami Formation HFC5 Cycle or Formation HFC3 HFC2 HFC1 HFC4 Maximum Permeability

-80

-70

-60

-50

-40

-30

-20

-10 0

10 0.1 10 1000 100000 milliDarcies Elevation (ft msl)

Porosity 0

20 40 60 Percent Grain Density 2.60 2.70 2.80 grams/cubic centimeter HFC = high frequency cycle

2.4.12-143 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Table 2.4.12-207 Figure 2.4.12-238 Vertical Anisotropy Ratio from Rock Core Testing Cycle or Formation HFC5 HFC4 HFC5 Tamiami Formation HFC1 HFC2 HFC3

-80

-70

-60

-50

-40

-30

-20

-10 0

10 0.000001 0.0001 0.01 1

100 10000 1000000 Kv/Kh Elevation (feet msl)

HFC = high frequency cycle

2.4.12-144 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-239 Units 6 & 7 Aquifer Pumping Test Locations

2.4.12-145 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 210 Figure 2.4.12-240 Transmissivity of the Upper Floridan Aquifer

2.4.12-146 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 210 Figure 2.4.12-241 The Boulder Zone in Southern Florida

2.4.12-147 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-242 Piper Trilinear Diagram of Hydrogeochemical Samples Source data for this figure is found in Table 2.4.12-211 Note: Where sodium concentrations are unavailable, the concentration was estimated by subtracting the sum of the remaining cations (in milliequivalents per liter) from the sum of the anions (in milliequivalents per liter) and converting the result into milligrams per liter.

2.4.12-148 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 215 Figure 2.4.12-243 Generalized Hydrogeologic Section

2.4.12-149 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-244 Typical Injection Well System

2.4.12-150 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 260 Figure 2.4.12-245 Design of Exploratory Well EW-1

2.4.12-151 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 261 Figure 2.4.12-246 Design of Dual-Zone Monitor Well DZMW-1





































67((/3,73,3(

:$//7+,&.1(66

67((/&$6,1*

:$//7+,&.1(66

67((/&$6,1*

:$//7+,&.1(66

67((/&$6,1*

:$//7+,&.1(66

)5378%,1*

)((7

GROUND 685)$&(

'(37+%(/2:

'8$/=21(021,725:(//

2.4.12-152 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-247 Subsurface Hydrostatic Loading