Enclosure 9 to E-52844 Proposed Changes to CoC 9302, Revision 8 to E-52844 Proposed Changes to CoC 9302 Revision 8 NRCFORM618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10'CFR71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. *a. CERTIFICATION NUMBER I b; REVISION NUMBER I c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9302

-e-f91 71-9302 USA/9302/B(U)F-96 1 OF 19

2.

PREAMBLE

a.

This certificate is issued to certify that the package (packaging and contents) described In Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, "Packaging and Transportation of Radioactive Material."

b.

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or.other applicable regulatory agencies including the government of any country through or into which the package will be transported.

3.

THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION.

Remove the period TN Americas, LLC.

71S5 Minstrel Way, Suite 300 Columbia, MD 21045

d.

TITLE AND IDENTIFICATION OF REPORT OR APPLICATION NUHOMS-MP197 Transportation Package (.L Safety Analysis Report, Revision No. t8, aared r

~-

!TBD!

~

4.

CONDITIONS

5.

This certificate is conditional upon fulfilling the requirements of 10 CFR Part71, as applicable, and tl;le.conditions specified below.

(a)

Packaging (1)

Model Nos: NUHOMS-MP197, NUHOMS-MP197HB (2)

==

Description:==

NUHOMS~MP1.97 The NUHOMS~MP197 pac~age con~ists of ~n outer packaging, used for the transport of the NUHOMs~e1 BT dry shielded canister (DSC). Weights arid dimension noted below are approximat_e values'.

Packa~ing The NUHOMS-MP197 packaging is fabricated primarily of stainless steel. Non-stainless steel items include the lead.shielding between the containment boundary inner shell and the.structural shell, the 0-ring seals, the neutron shield, and carbon steel closure bolts. The body of the packaging consists of a 1.25 inch thick, 68 inch inside diameter, stainless stee.1 inner (containment) shell ;:ind a 2.5. inch thick, 82 inch outside diameter stainless steel structural shell, without impact limiters, which sandwich the 3.25 inch thick cast lead shielding. The packaging is 208 inches long and has an outer diameter of 91.5 inches. The weight of the packaging body is 148,840 pounds including about 10,000 pounds of neutron shield and 60,000 pounds of cast lead.

Page 1 of 9 I

I.

to E-52844 Proposed Changes to CoC 9302 Revision 8 NRC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10CFR71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATION NUMBER I
b. REVISION NUMBER I
c. DOCKET NUMBER I
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9302

-er~

71-9302 USA/9302/B(U)F-96 3 OF 19 5.(a)(3)

Description, NUHOMS-MP197HB The NUHOMS-MP197HB package consists of an outer packaging, which is used for the off-site transport of any one of the nine NUHOMS DSCs (24PT4, 24PTH, 32PT, 32PTH, 32PTH1, 37PTH, 61 BT, 61 BTH, and 698TH). It is also used to transport a secondary container (Radioactive Waste Container (RWC)) with dry irradiated and/or contaminated non-fuel bearing solid materials. Weights and dimensions are approximate values, unless otherwise noted.

Packaging The MP197HB packaging is a modified version of the MP197 packaging described in 5(a)(2).

The packaging is fabricated primarily of nickel-alloy steel (NAS). Other materials include the cast lead shielding between the containment boundary inner shell and the structural shell, the 0-ring seals, the resin neutron shield, and the carbon steel closure bolts. Socket headed cap screws (bolts) are used to secure the lid to the package body and the RAM access closure plate to the bottom of the package. The body of the packaging consists of a NAS inner shell, 1.25 in.ch thick with a 70.5 inch inside diameter, and a NAS outer shell, 2.75 inch thick with a 84.5 inch outside diameter, which sandwich the 31nch* thick cast lead shielding material.

The packaging is 271.25 inch long with a diameter of 126 inches, when both impact limiters are installed. The pac;:kaging diameter, including the radial neutron shield, is

97. 75 inches witnput tli.e fins or 104.25 inche.s With the fins. The fins are an optional feature for heat loads less than or equal to 26 kW. The packaging cavity is 199.25 inches long and 70_.5 inches* in diameter without the internal sleeve.(discussed below or 68 inches in diameter with the~slee Remove "aluminum" The MP197HB uses an internal s ** eve for smaller diameter DSCs and secondary cqntainers. The inner s. '.. I. esigned with slots to accommodate the existing rails inside the packaging and to provide rails inside the sleeve on which the smaller diameter DSCs or secondary containers slide during horizontal loading or unloading of the package.

The gross weight of the loaded package is 152 tons including a maximum payload of 56 tons. Four removable trunnions, attached to the package t>ody, are provided for lifting and handling operations, including rotation of the packaging between the horizontal and vertical orientations.

The package containment boundary consists of the inner shell, a 6.5 inch thick bottom plate with a 28.88 inch diameter, a 2.5 inch thick RAM access closure plate with seal and bolts; a package body flange, a 4.5 inch thick lid with seal and bolts, vent and drain ports with closures bolts and seals, and all containment welds.

Page 2 of 9 to E-52844 Proposed Changes to CoC 9302 Revision 8 NRCFORM618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10CFR71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATION NUMBER I
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER I

PAGE PAGES 9302

--g-~

71-9302 USA/9302/J3(U)F-96

4. OF 19 5.(a}(3)

Add: "For contents loaded in a Dry Descnpt1on, NUHOMS -MP197HB con Shielded Canister (DSC), an" pt{i mosphere (helium) is maintained in the package cavity. Helium assists in heat removal and provides a non-reactive environment to protect the fuel assemblies against fuel cladding degradation. Shielding is provided by approximately 4 inches of steel, 3 inches of lead and 6.25 inches of neutron shielding assembly.

To accommodate the NUHOMS-69BTH DSC with heat loads greater than 26 kW, removable external fins are provided for the packaging.

Dry Shielded Canister (DSC}

The function of the DSC, which is placed within the transport package, is identical to that described for the MP197 cask in 5(a)(2) above. The DSC consists of a stainless steel shell and ~ basket assembly~ The PSC basket assembly provides criticality contro.1 and contains a storage position for each fuel assembly. No credit is taken for the DSC as a containment boundary.

Remove "aluminum" There are nine DSC designs and a radioactive waste canister auth rized for transport in the NUHOMS-MP197HB packaging. The packciging cavity is de igned to accommodate the larger 69.8 inch diameter DSCs (32PTH, 32PTH1, 7PTH, and 69B*. TH DSC}. To c1ccommodate the smaller 6. 7.~ i~.c. h diametert=*

~. 24PTH, 32PT, 61 BT, and 61 BTH DSC) or secondary container (RWC},.

nner sleeve is provided. Tq accommo.d.ate the varyin*g lengths of the

  • condary containers, stainless steel or aluminum spacers are provided to limit axial movement of the payload. Spa_cers are to be installed in the MP197HB overpack or DSC cavity, if necessary, to limit the axial gaps betWeen the components, as specified n Chapter A.7, Table A.7-1 of the application.

The maximum weight of the payload (DSC including the fuel} is limited to 56 tons.

The DSC b?sket poison plates are *ccm*structed from Boral, borated aluminum or aluminum/84C metal matrix composite (MMC) and provide a heat conduction path from the fuel assemblies to the ?anister wa*11, as well as the necessary criticality control.

Radioactive Waste Container (RWC)

The RWC consists of a payload of dry irradiated and/or contaminated non-fuel bearing solid materials. No credit is taken for the containment provided by the RWC.

The RWC assembly together with any appropriate cask cavity spacers shall provide an equivalent of 1.75 inches minimum steel shielding in the radial direction. A minimum of 5.75 inches equivalent steel shielding shall be provided at the bottom of the canister and a minimum of 7.00 inches equivalent steel shielding at the top of the canister. The maximum weight of the payload (RWC, including waste) is limited to 56 tons.

Page 3 of 9 to E-52844 Proposed Changes to CoC 9302 Revision 8 NRCFORM618 U.S. NUCLEAR REGULATORY.COMMISSION (8*2000) 10CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATION NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 5.(a)(4) 5.(a)(5) 9302

-a-[]

71-9302 Drawings, NUHOMS-MP197 (continued) 1093-71-14, Revision 1, NU HOMS-61 BT Transportable Canister for BWR Fuel General Assembly 1093-71-15, Revision 2, NUHOMS~61 BT Transportable Canister for BWR Fuel Shell Assembly 1093-71-16, Revision 0, NUHOMS-61 BT Transportable Canister for BWR Fuel Shell Assembly 1093-71-17, Revision 2, NUHOMS-61BTTransportable Drawings, NUHOMS-MP197Ha USA/9302/B(U)F-96 6 OF Canister for BWR Fuel Canister Details 1093-71-18, Revision 1, NUHOMS-61 BT Transportable Canister for BWR Fuel Canister Details 1093-71-20, Revision O, NUHOMS~MP197 Packaging Regulatory Plate 1093-71-21, Revision 0, NUHOMS-MP197 Packaging on Transport Skids 19 The NUHOMS-MP197HB package shall be constructed and assembled in accordance with the following Transnuclear, Inc. drawings:

MP197HB-71-1001 Rev[]

MP197HB-71-1002 RevLi MP197HB-71-1003 Rev[]

MP197HB-71-1004 Rev~

MP197HB-71-1005 Rev[!]

MP197HB-71-1006 Rev@]

MP197HB-71-1007 Rev[]

MP197HB-71-1008 Reve:J MP197HB-71-1009 Rev[+/-]

NUHO~S.. MP197HB Packaging Transport Configuration (2 sheets)

NUHOMS~MP197HB Packaging Parts List (2 sheets)

NUHOMS~MP197HJ3 Packaging General Arrangement (1 sheet)

NUHOMS-MP1971-!B Packaging Cask Body Assembly (1 sheet)

NUHOMS-MP1 ~7HB Packaging Cask Body Details (3 sheets)

NUHOMS-MP197HB Packaging Lid. Assembly And Details (1 sheet)

NUHOM&l?~MP197HB Packaging Regulatory Plate (1 sheet)

NUHOMS-MP197HB Packaging Impact Limiter Assembly (1 sheet)

NUHOMS-MP197HB Packaging Impact. Limiter Details (1 sheet)

Page 4 of 9

\\

to E-52844 Proposed Changes to CoC 9302 Revision 8 NRCFORM618 U.S. NUCLEAR REGULATORY COMMISSION (8*2000) 10CFR71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a; CERTIFICATION NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIF19ATION NUMBER I PAGE 9302

~'91 71~9302 USA/9302/13(U}F-96 7 OF MP197HB-71-1011 Revl2]

MP197HB-71-1014 Reve:J NUH24PT4-71-1001 Rev 0 NUH24PT4-71-1002 1

NUH24PT4*71-1003 Rev 0 NUH32PT-71-1000 Rev 0 NUH32PT-71-i001 Rev 1 NUH32PT-'71-1002 Rev 1 NUH32PT-71-1003 Rev 1 NUH32PT-71-1004 Rev 1 NUH32PT-71-1005 Rev 1 NUH32PT-71-1006 Rev 1 NUH32PT-71-1007 Rev 1 NUH24PTH-71-1000 Rev 1 NUH24PTH-71-.1001 Rev 1 NUH24PTH-71-10Q2 Rev 1 NUH24PTH-71-1003 Rev 2 NUHOMS-MP197HB Packaging Transport Configuration Outer Sleeve With Fins Option (1 sheet)

NUHOMS-MP197HB Packaging Internal Sleeve Design

~ sheet\\)

UHOMS 24PT4 Transportable Canister For PWR Fuel Basket Assembly (5 sheets}

NUHOMS 24PT4 Transportable Canister For PWR Fuel Main Assembly (8 sheets)

NUHOMS 24PT4 Transportable Canister For PWR Fuel Failed Fue.1 Can (4 sheets)

NUHOMS 32PT Transportable Canister For PWR Fuel Summary Dimensions (1 sheet)

NUHOMS 32PT Transportable Canister For PWR Fuel Main Assembly (5 sheets)

NUHOMS 32PT Transportable Canister For PWR Fuel Shell Ass~mbly (3 sheets)

NUHQMS 32PT Transportable Canister For PWR Fuel "A" 1?asket Asser:nbly (16 Poison/16 Compartment Plates)(8 sheets}

NUHOfv1S 32PT Transportabl1;1 Canister For PWR Fuel Aluminum Ti'~nsition Rail - R90 (2 sh~ets)

NUHOMS 32PT Transportable Canister For PWR Fuel Aluminum Transition Rall -R45 (1 sheet)

NU~OMS 32PT Transportable Canister For PWR Fuel "A/B/C/D" Basket Assembly (20 Poison/12 Gompartment Plates)(6 sheets)

NUHOMS 32PT Transportable Canister For PWR Fuel "A/B/C/0" Basket Assembly (24 Poison/8 Compartment Plates)(8 sheets)

NUHOMS24PTH Trarisportab.le *Canister For PWR Fuel Main Assembly (5 shee.ts)

NUHOMS24PTH Transportable Canister For PWR Fuel Basket Shell Assembly (4 sheets)

NUHOMS24PTH. Transportable. Canister For PWR Fuel Shell Assembly (4 sheets)

NUHOMS24PTH Transportable Canister For PWR FuelBasket Assembly (8 sheets}

Page 5 of 9 PAGES t9 to E-52844 Proposed Changes to CoC 9302 Revision ?

NRC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10CFR71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATION NUMBER I
b. REVISION NUMBER I
c. DOCKET NUMBER I
d. PACKAGE IDENTIFICATION NUMBER PAGE 9302

-a-f9l 71-9302 USA/9302/B(U)F-96 11 OF NUH61BTH-71-1103 Rev 1 NUH61BTH-71-1104 Rev1 NUH61 BTH-71-1105 Rev 1 NUH61 BTH-71-1106 Rev 2 NUH69BTH-71-1001 Rev 3 NUH69BTi-l-71-1002 Rev 3 NUH69BTH-71-1003 Rev 3 NUH69BTH-71-1004 Rev 6 NUH69BTH-71*1011 Rev 3 NUH69BTH-71-1012 Rev 4 NUH69BTH* 71-1013 Rev 4 NUH69BTH* 71-1014 Rev 2 NUH69BTH-71-1015 Rev 2 NUHRWC-71-1001 Reve::J NUMRW0--71-1002 Rev 1 NU HOMS 61 BTH Type 2 Transportable Canister For BWR Fuel Transition Rails (2 sheets)

NU HOMS 61 BTH Type 2 Transportable Canister For BWR Fuel Damaged Fuel End Caps (1 sheet)

NUHOMS 61 BTHF Type 2 Transportable Canister For BWR Fuel Failed Fuel Can (2 sheets)

NUHOMS 61 BTH Type 2. Transportable Canister For BWR Fuel Top Grid Assembly Alternate 3 (2 sheets)

NUHOMSB9BTH Transportc1ble Canister For BWR Fuel Main Assembly (4 sheets)

NUHOMS' 698TH Transportable Canister For BWR Fuel Basket -

Shell Assembly (4 sheets)

NUHOMS 698TH Transportable Canister For BWR Fuel Shell Assernbly (4 sheets)

NUHOMS 698TH Transportable Canister For BWR Fuel Alternate Top Closure (7 sheets}

NUHOMS 698TH Transportable Canister For BWR Fuel Basket Assembly (5 sheets)

NUHOMS 698TH Transportabl~ Canister For BWR Fuel Transition Rail Assembly And Details (6 she~ts)

NUHOMS*69BTH Transportable Canister For BWR Fuel Holddown Ring Assembly (2 ~heats)

NUHOM_S 6913TH Trcj.nsportable Canister For BWR Fuel Damaged Fuel Modification (1 sheet)

. Radioactive Waste Canister NUHOMS 6913TH Transpo Fuel End Caps (1 st:ieet)

N UHOMS System RV\\lf.G-t:~:iSteH'-JAA.*IEIEl-=f=e&--8Aiiela-121!:fe-I~iGA

~

(-&sheets)

NUI 10~8 Syste~er Welded Top S~ield Plug DesigA lnflerl111~1 (3~

--l'INHeUH'HffR'¥.:l.6'-lfo.'C-7'-11~1H,QA,Q'd3-f'R'Ne9WV-'c01----NUHOMS System RWC c,mister

  • Bolted Iop Sbie!d Ph 19 Design iVialn Assembly (4 sheets)

Page 6 of 9 PAGES 19 to E-52844 Proposed Changes to CoC 9302 Revision 8 NRCFORM618 U.S. NUCLEAR REGULATORY COMMISSION (8-200_0) 10CFR 71 GERTI FICATE' OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a.. CERTIFICATION NUMBER I b. REVISION NUMBER I c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER l PAGE PAGES 9302

-a-~

71-9302 USA/9302/B(U)F-96 17 OF 19

7.

In addition to the requirements of Subpart G of 1 o CFR Part 71, the NUHOMS-MP197 and NUHOMS-MP197HB packages shall:

(a)

Be prepared for shipment and operated in accordance with the Operating Procedures in Chapters 7.0 and A.7 of the application, respectively; and (b)

Meet the Acceptance Tests and Maintenance Program of Chapters 8.0 and A.8 of the application, respectively.

8.

Additional operating requirements of the NUHOMS-MP197 package include:

(a)

(b)

Verification of the basket type A, B, or C, by inspection of the last digit of the serial number on the grapple ring at the bottom of the DSC.

Verification that the fuel assemblies to be placed in the DSC meet the maximum burnup, maximum initial enrichment, minimum cooling time, and maximum decay heat limits for fuel assemblies as speqified in Tables 2 and 3. The enrichment limit must correspond to the basket type determined in 8(a) above.

Add "of DSCs" (c)

Replacement Qf the pack e 1d bolts after 85, or fewer, roundtrip shipments to ensure that the allowable fatigu~dama. fa tor will not be exceeded during normal conditions of transport.

9.

Additional operating requ* ments _f the NUHOMS-MP197HB package include:

(a)

Transportation s limited ta facilities that have the capal;>ility to handle uncanned damaged fuel assemblies.

(b)

(c)

Detailed site-specific pro edures shall 'be developed to address site spe~ific conditions and requirements that may r quire the use of different equiprpent and ordering of *steps to accomplish the same o 1ectiVes or a~ceptahc~ criteria wh,ich must be met to ensure the integrity of the packa~e.

_ ~

Prior to transportation, the condition of th~ eal'.'.l.i~ must be evaluated to verify that (i) the containment function of the ~

is maintained and (ii) the degradation of neutron absorbers and basket materials has not oeplurred to the extent they would rio longer comply with applicable materials and dimensions, as s,pecified in_ condition 5(a)(5). The verification of the containment function shall follow the instru tions outlined in Chapter A.7, Section A.7.1.3, Step 5 of the application. The effectivene s of the inspection and verification techniques, outli ti in Chapter

. A. 7, Section A. 7.1.3, Step, shall be demonstrated on mockups or working s ems, prior to transportation.

Add ",titled "Evaluation,""

Add "DSC" Page 7 of 9 to E-52844 Proposed Changes to CoC 9302 Revision 8 NRC FORM.618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10CFR71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATION NUMBER I
b. REVISION NUMBER I
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER I PAGE PAGES 9302

.,...~

71-9302 USA/9302/B(U}F-96 18 OF 19 (d)

The aging management plan and evaluation for each~~

~hall be submittedtotheNRCpriortoshipment.

~

~

(e)

Replacement pf the package lid bolts after 250, or fewer, round trip shipments to ensure that the allowable fatigue damage factor will not be exceeded during normal conditions of transport.

10.

The NUHOM$-rv1P197 and NUHOMS-MP197HB packages are approved for e)(clusive use by rail, truck, or marine transport. Transport by air is not authorized.

11.

The NUHOMS-MP197 and NUHOMS-MP197HB packages authorized by this certificate are hereby approved for use under the 9eneral license provisions of 1 O CFR 71. 17.

12.
13.

Revision No~f this certificate may be used until -M&'j' 01, '8-:-- !TBD I Expiration Date: JS..

ust 31, 2022.

8 Page 8 of 9 to E-52844 Proposed Changes to CoC 9302 Revision 8 NRCFORM618 (8-2000)

U.S. NUCLEAR REGULATORY COMMISSION 10CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATION NUMBl;R I
b. REVISION NUMBER I
c. DOCKET NUMBER I
d. PACKAGE IDENTIFICATION NUMBER 9302

..g_fgl 71-9302 USA/9302/B(U)F-96 REFERENCES I

PAGE..

PAGES 19 OF 19 NUHOMS-MP197 Transportation Package Safety Analysis Report, Revision No. ~i:112~:J'.

  • 1 Date:~? 2, gg17 jTBD j jTBD I E Ut. NrU~E:;R iGULATORY COMMISSION

,;,. u J --; ll\\Aljf1z

./ n

/,'\\

ti

\\

John iyicKirgan, Chief Spen( Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Page 9 of 9