July 20, 2018 Mr. Pierre M. Saverot, Project Manager, Spent Fuel Licensing Branch Division of Spent Fuel Management - Office of Nuclear Material Safety and Safeguards (NMSS) U.S. Nuclear Regulatory Commission Two White Flint North-Mail Stop T4-B34 11545 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
REQUEST TO AMEND CERTIFICATE OF COMPLIANCE 9316 USNRC
Reference:
Docket No. 71-9316 AOS
Reference:
FM9006.1-072018-002 Mr. Saverot:
Alpha-Omega Services, Inc. (AOS) would like to request an amendment to Certificate of Compliance No. 9316. We are requesting approval for three changes.
1.
We would like to make some changes related to the Shipping Cage fastening screws.
We have experienced a problem with the Type 410 stainless steel screws that secure the Shipping Cage to the Transport Pallet on the AOS-100A. Galling has been identified on some screws causing the screws to seize. This has resulted in some Keenserts backing out of the Shipping Cradle during disassembly (refer to AOS Drawing 105E9711, item 13).
To reduce the occurrence of galling, we would like to reduce the torque for these screws from 62.5 ft-lb to 37 ft-lb. This torque is appropriate for 1/2"-13 UNC lubricated screws.
Also, we would like to add an optional material, Nitronic 60 per ASME SA-193, ASTM A193 Grade B8S (UNS S21800) for the Shipping Cage screws (105E9711 item 10).
We have updated section 2.5.3.1.4 of the SAR to analyze the new screw material. At the same time, we are correcting an error in the geometry of the Shipping Cage shown in this section of the SAR. Previously, the Shipping Cage was shown sitting on top of the Transport Pallet with the screws passing vertically through flanges on four sides of the Shipping Cage. The actual configuration of the AOS-100A has vertical flanges that straddle the Shipping Cage and the screws pass horizontally through
9156RoseStreetP.O.Box789Bell"ower,California,U.S.A90706 CustomerService(800)3467894(562)8040604Fax:(562)8040610 www.alphaomegaserv.com the flanges. The revised analysis reflects the proper configuration.
Also associated with his change, we would like to add an optional shipping cage closure - to be used either for a repair if we are unable to re-install a Keensert in the field according to the manufacturers instructions; or for replacement. The optional shipping cage closure uses a flanged nut and modified bolt to replace the Keenserts.
These changes are shown on the attached drawing, 105E9711 Revision K; and the drawing revision is referenced in Chapter 1 of the SAR (revision to Section 1.3.1 and Table 5).
2.
We are requesting the addition of new isotopes to the authorized contents.
We have revised the Shielding Analysis in Chapter 5 (addition of Appendices 5.5.5, 5.5.6 and Appendix 5.5.7); and revised Package Operations in Chapter 7 (addition of Appendix 7.5); of the SAR to consider beta emitting isotopes and low energy gamma emitting isotopes.
3.
We are adding an analysis of the Normal Conditions of Transport (NCT) drop test of the AOS-100A with the Shipping Cage installed.
The analysis is included in Appendix 2.12.16 and shows that the Shipping Cage will remain intact following the NCT drop test.
With the addition of this analysis to the SAR, we request that Condition 15 be removed from the Certificate of Compliance.
Attached for your review are the revised chapters of SAR FM9054, revision H-5.
Best Regards, Troy Hedger, President Alpha-Omega Services, Inc.
Attachments:
List of Changes to Drawing 105E9711 Rev. K (July 12, 2018)
List of Changes to SAR AOS-FM9054 (July 20, 2018)
Certification Drawing 105E9711 Rev. K (July 12, 2018)
SAR FM9054 Revision H-5 dated July 20, 2018 (revised sections only)
AOS Affidavit for withholding from public records (re: certification drawing)
Drawing105E9711,RevKChanges-July12,2018 1
Drawing105E9711,RevKUpdates-Trackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
Sheet1of2 B1 REVISIONS Rev.J;FM9006.1082017003;08302017;JA Rev.K;FM9006.1072018001;07122018;JA Note:Rev.KalsoshowninTitleBlock(2sheets);andFM numbershowninbottomrighthandcornerofpage(2 sheets)
G4 NOTES TriangleNote6,TORQUETO62.5ftlb(85Nm)
LUBRICATED
<Replacednoteasfollows;toreducetheoccurrenceof galling/seizingoftheShippingCageScrewstotheShipping CradleKeenserts.>
TriangleNote6,TORQUETO37ftlb(50Nm)LUBRICATED G4 NOTES
<AddedNoteasfollows.>
TriangleNote8,OPTIONALITEMSAND/ORMATERIAL DESIGNATEDFORUSEWITHPACKAGEASSEMBLY.SHIPPING CAGECLOSUREPERSECTIONCCISOPTIONAL;USINGASLAB FLANGEDWELDNUT(ITEM15)SECUREDTOTHESHIPPING CAGEASSEMBLYWITHTWO(2)3/816UNCFLATHEADHEX SOCKETSCREWS(ITEM16),NUTS(ITEM17),ANDLOCK WASHERS(ITEM18);ANDMODIFIED1/213UNCHEXHEAD BOLT(ITEM19).
E5 ITEM10
ASMESA193/ASTMA193,GRADEB6(UNS S41000)
<Expandedtoaddoptionalmaterialspecificationforthe ShippingCagescrews;basedonupdatedSARSection 2.5.3.1.4analysis.>
ASMESA193/ASTMA193,GRADEB6(UNSS41000)OR NITRONIC60PERASMESA193/ASTMA193,GRADEB8S (UNSS21800).;and AddTRIANGLENOTE8reference D8 ITEM15
<Addoptionalmaterialdesignationforshippingcageclosure forrepairorreplacement.>
ITEM15;A/R;SLABFLANGEDWELDNUT;DETAILDWG; ASMESA240,SA479,SA312/ASTMA240,A479,A312, TYPE304OR316;ORMANUFACTURERPARTNUMBER;C; and AddTRIANGLENOTE8reference
Drawing105E9711,RevKChanges-July12,2018 2
Dwg.Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
D8 ITEM16
<Addoptionalmaterialdesignationforshippingcageclosure forrepairorreplacement.>
ITEM16;A/R;FLATHEADHEXSOCKETSCREWS3/816 UNCX1.5;DETAILDWG;ASMESA193/ASTMA193,GRADE B6(UNSS41000)ORNITRONIC60PERASMESA193/ASTM A193,GRADEB8S(UNSS21800);C;and AddTRIANGLENOTE8reference C8 ITEM17
<Addoptionalmaterialdesignationforshippingcageclosure forrepairorreplacement.>
ITEM17;A/R;HEXNUT3/8;DETAILDWG;ASMESA 194/ASTMA194GRADE6UNCS41000ORNITRONIC60PER ASMESA194/ASTMA194,GRADE8S(UNSS21800);C;and AddTRIANGLENOTE8reference C8 ITEM18
<Addoptionalmaterialdesignationforshippingcageclosure forrepairorreplacement.>
ITEM18;A/R;LOCKWASHER3/8;DETAILDWG;188 STAINLESSSTEEL,PERASMEB18.21.1,TYPEB,McMASTER CARRPN91831A127OREQUIVALENT;C;and AddTRIANGLENOTE8reference C8 ITEM19
<Addoptionalmaterialdesignationforshippingcageclosure forrepairorreplacement.>ITEM19;A/R;HEXHEADBOLT 1/213UNCX2MODIFIED;DETAILDWG;ASMESA 193/ASTMA193,GRADEB6(UNSS41000)ORNITRONIC60 PERASMESA193/ASTMA193,GRADEB8S(UNSS21800);C; and AddTRIANGLENOTE8reference Sheet2of2 H8 BalloonItem 3
NAMEPLATE DETAILA
<Fixedtypo,inDetaildesignation.>
DETAILB E5 BalloonItem 3
PACKAGINGNAMEPLATESEEDETAILA
<Fixedtypo,inDetaildesignation.>
DETAILB
Drawing105E9711,RevKChanges-July12,2018 3
Dwg.Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
B5 Center Elevation BalloonItems14,10HEXBOLTSITEM14 OPTIONAL
<Expandedtoincludeinformationforoptionalshippingcage closureforrepairorreplacement.>
Addrepresentationofoptionalcageclosureinview;and SECTIONCCindicator; BalloonItems14,10ITEM14OPTIONAL,SEESECTIONCC AND(TRIANGLENOTE)8FOROPTIONALCLOSUREMETHOD.
A7 SECTIONCC
<Addedoptionalshippingcageclosuredetailforrepairor replacement.>
SECTIONCCOPTIONALSHIPPINGCAGECLOSURE
AOSFM9054,RevH5Changes-July20,2018 1
AOSFM9054,RevH5Updates-Trackingpagenumber,headinglevel,paragraphnumber,linenumber;whatitwas,whatitis,andjustification(ifneeded)
Page Heading/
Item Para#/Item Line#/Item Whatitwas(RevH4)
Whatitis(RevH5)
FrontMatter i
Cover Rev.H4,November28,2017 Rev.H5,July20,2018 (Notetoreviewer:Automaticallyappliedtoallfooters.Due tosoftwareconstraints,SARpagefootersmight/might notincludearevisionbarindicatingthischange.Additionally, therevisionbarmightspanbothlinesofthefooter.)
iii Revision History
<AddedRevisionH5,July20,2018entry.>
Chapter1-RevisedSubsection1.2.2(addeddiscussion relatingtoisotopemixtures);
revisedTable12(deletedfootnoteeandrenumbered remainingfootnotes);added Table12b(ExclusiveUseActivityLimits-ModelsAOS100AandAOS100AS);updated Table15drawingrevisions
Chapter2-ReplacedParagraph2.5.3.1.4;added Appendix2.12.16(ShippingCageLSDYNAImpact Analysis-ModelAOS100)
Chapter5-AddedAppendix5.5.5(Shipments ofMultipleIsotopes-ModelsAOS100Aand AOS100AS),Appendix5.5.6(IsotopesInsignificantto ExternalDoseRates),andAppendix5.5.7(ExclusiveUse ActivityLimits-ModelsAOS100AandAOS100AS)
Chapter7-AddedAppendix7.5.1(DoseRate andDecayHeatLimitCompliance)
Appliedmiscellaneouscorrections(tableofchanges includedwithcoverpageofthesubmittal)
AOSFM9054,RevH5Changes-July20,2018 2
Page Heading/
Item Para#/Item Line#/Item Whatitwas(RevH4)
Whatitis(RevH5)
Chapter1 19 1.2.1.4 1
3 RefertoTable12andTable12aforthe
<Addedreferencetonewtable.>
RefertoTable12,Table12a,andTable12bforthe 110 1.2.2 1,2,and abulletset (was1)
Multiple Table12andTable12aprovidealistofthe isotopesauthorizedforusewiththeAOS TransportPackagingSystem.Additionally, Table12andTable12ademonstratethe useofcuriecontenttomeettheradioactiveand thermalmaximumlimitsspecifiedinTable13, eachtransportpackagemodel.
<Expandedtosupportisotopemixturesandexclusiveuse.>
Table12andTable12aprovidealistoftheisotopes authorizedforusewiththeAOSTransportPackagingSystem.
Isotopemixturesarepermittedwithintheshippingcask contentswhenexternaldoserateanddecayheatlimit complianceisdemonstratedpertheguidancespecifiedin Appendix7.5.1,DoseRateandDecayHeatLimit Compliance.Isotopesthatemitonlylowenergygammas (thatis,allemissionsarelessthan0.3MeV)and/orbeta particlesarepermittedfortransport.Isotopesthatmeet thiscriteria:
Donotneedtobeconsideredfordoseratecalculations
Needtobeaccountedforonlywhencalculatingthe shippingcaskcontentstotaldecayheat Table12andTable12ademonstratetheuseofcurie contenttomeettheradioactiveandthermalmaximumlimits specifiedinTable13,forindividualisotopeswithineach transportpackagemodel.
110 1.2.2 5(was4) 2 fornonexclusivetransport,exceptfor Co60Cquantities.(RefertoTable12.)
fornonexclusivetransport.(RefertoTable12and Table12a.)
110 1.2.2 6(was5) 2
<Fixedtypo,appendedperiodtoendofsentence.>
110 1.2.2 2(was1) 8(was7)
<Appendednewsentencetoendofparagraph.>
ForModelsAOS100AandAOS100AS,whenshippedas exclusiveuse,theactivitylimitsforeachisotopeare specifiedinTable12b.
110a 110b 1.22
<Addednewsubpages,includingblankpage,due topage110overflow.>
111 111a Table12 Table12a DecayHeat heading DecayHeatCi/Watt
<CorrectedUOM.>
DecayHeat(W/Ci) 111 Table12 DecayHeat column AllIsotope rows 6.45E+01,6.45E+01,6.45E+01,2.00E+02, 2.31E+02,6.17E+01,2.33E+02,3.92E+02
<Correctedvaluestomatchvaluesusedelsewherein thedocument.>
1.55E02,1.55E02,1.55E02,4.99E03,4.33E03,1.62E02, 4.29E03,2.55E03
AOSFM9054,RevH5Changes-July20,2018 3
Page Heading/
Item Para#/Item Line#/Item Whatitwas(RevH4)
Whatitis(RevH5) 111 Table12 Co60Crow Footnotee Originalfootnoteetext:
MustbeshippedbyExclusiveUse.
<Omittedfootnotee,whichcausedremainingfootnotes torenumber.>
111a 111b Table12b Table13
<AddednewTable12b,ExclusiveUseActivityLimits-ModelsAOS100AandAOS100AS,onpage111b (previouslyblank),andmovedTable13frompage111a topage111b.>
117 Table15 ListedDrawingRevisions,byModel#Column:
Assembly:IIIII Cask:HHJJJ CavitySpacerPlates:--A-A
<Updatedtonewrevisions,byModel#Column.>
Assembly:JJKKK Cask:IIKKK CavitySpacerPlates:--B-B Chapter2 226 Figure212 Caption CenterofGravity-ModelAOS1002
<Fixedtypo,omitted2fromModel#.>
CenterofGravity-ModelAOS100 255 2.5.3.1.4 All All
<Replacedentiresectionwithnewcontent.>
279 2.6.7
<AddedNotetobeginningofcontent.>
Note:Thefollowinganalysisdoesnotconsidertheenergy thattheshippingcageabsorbsduringafreedrop.Forthe FreeDropShippingCageanalysis,refertoAppendix2.12.16.
2155 2.12 16bullet (new)
<Addedcrossreferencetonewappendix>
- ShippingCageLSDYNAImpactAnalysis-ModelAOS100 2942aq-2942bh 2.12.16
<Addednewappendix.>
2.12.16ShippingCageLSDYNAImpactAnalysis-ModelAOS100.
AOSFM9054,RevH5Changes-July20,2018 4
Page Heading/
Item Para#/Item Line#/Item Whatitwas(RevH4)
Whatitis(RevH5) 2944-2945
[2.35]-
[2.41]
<Addednewreferencesinsupportofnew Appendix2.12.16.>
[2.35]U.S.NuclearRegulatoryCommission(NRC),Title10, CodeofFederalRegulations,Part71.71(10CFR71.71),
PackagingandTransportationofRadioactiveMaterial-Normalconditionsoftransport,2015.
[2.36]LivermoreSoftwareTechnologyCorporation(LSTC),
LSPrePost,Version4.3,2016.
[2.37]Autodesk,AutodeskInventorProfessional,2016.
[2.38]ANSYSInc.,ANSYSWorkbench,Release15.0,2015.
[2.39]ANSYSInc.,ANSYSMechanical,Release15.0,2015.
[2.40]LSTC,LSDYNAKeywordUsersManual,VolumeI, Version971,2007.
[2.41]LSTC,LSDYNAKeywordUsersManual,VolumeII, Version971,2012.
2946 Blank
<Addedintentionallyblankpageatchapterend.>
Chapter3 32 3.1.2 1
3 DecayHeat(Ci/W)values
<CorrectedUOM.>
DecayHeat(W/Ci)values 32 3.1.2 1
5+
<Appendednewsentence.>
Themethodthatisusedforcalculatingthedecay heatforisotopemixturesinModelsAOS100A andAOS100ASispresentedinAppendix5.5.5,Shipments ofMultipleIsotopes-ModelsAOS100AandAOS100AS.
Chapter4-Nochanges
AOSFM9054,RevH5Changes-July20,2018 5
Page Heading/
Item Para#/Item Line#/Item Whatitwas(RevH4)
Whatitis(RevH5)
Chapter5 56 5.2 1
2+
Foranysingleshipment,onlyoneisotopemay beloadedintothecask.Theexceptionstothis rulearethatIr194impuritiesmaybepresentin shipmentsofIr192,inquantitiesasdesignated inTable12a,Ir192andIr194ActivityLimits-AllModels,andNb95maybeloadedwith Zr95,butonlyasoutlinedinSubsection5.2.1.
<Addedexceptionforshippingmultipleisotopes.>
Ir194impuritiesmaybepresentinIr192shipments,in quantitiesasdesignatedinTable12a,Ir192andIr194 ActivityLimits-AllModels.Nb95maybeloadedwithZr95 inModelsAOS050andAOS100,butonlyasspecifiedin Subsection5.2.1.Shipmentofmultipleisotopesispermitted inModelsAOS100AandAOS100AS,asspecifiedin Appendix5.5.5.
521 5.4.4 1
1 Fortheactivitylimitsofallindividualisotopes, refer
<Correctedstatement.>
Fortheactivitylimitsofallindividualisotopesotherthan Ir192andIr194,refer 523 Table515 Co60Crow External SurfaceMax Dosevalue 3.974E03
<Correctedtransposednumbers.>
3.947E03 523 Table515 Footnotea RefertoTable517
<Changedtorefertocorrecttable.>
RefertoTable519 523 Table515 Footnoteb (new)
<Addednewfootnoteb,whichcausedremainingfootnotes torenumber.>
b.Higheractivitylimitsarepermissiblewhentransporting exclusiveuse.RefertoAppendix5.5.7.
524 Table516 Footnotea RefertoTable517
<Changedtorefertocorrecttable.>
RefertoTable520 528 5.5
<Addedintroductionandlistofappendixcontent.>
Thisappendixpresentsthefollowinginformation:
AOSCaskIsotopicHeatLoadCalculations IsotopeValuesforCalculations MCNP6InputandOutputFilesforDoseCalculations Cobalt60CVolumeSourceCalculation ShipmentsofMultipleIsotopes-ModelsAOS100A andAOS100AS IsotopesInsignificanttoExternalDoseRates ExclusiveUseActivityLimits-ModelsAOS100A andAOS100AS
AOSFM9054,RevH5Changes-July20,2018 6
Page Heading/
Item Para#/Item Line#/Item Whatitwas(RevH4)
Whatitis(RevH5) 528 5.5.1 4
5+
<Appendednewsentence.>
RefertoAppendix5.5.5fortheheatloadcalculations thataretobeusedforshippingmultipleisotopesin ModelsAOS100AandAOS100AS.
544a-544n Apx5.5.5 Apx5.5.6 Apx5.5.7
<Addedthreenewappendicesandblankpageatend.>
5.5.5ShipmentsofMultipleIsotopes-ModelsAOS100A andAOS100AS 5.5.6IsotopesInsignificanttoExternalDoseRates 5.5.7ExclusiveUseActivityLimits-ModelsAOS100A andAOS100AS Chapter6-Nochanges Chapter7 76 7.1.2.1 Stepa 2-3 inSection7.1.
inSection7.1andguidanceprovidedin Appendix7.5.1.
715 7.2 Stepe 3+
<Appendednewsentence.>
ForshippingmultipleisotopesinModelsAOS100Aand AOS100AS,refertoAppendix5.5.5,ShipmentsofMultiple Isotopes-ModelsAOS100AandAOS100AS.
719 719a
7.5 7.5.1 7.5APPENDIX(NONE)
<Addednewappendixcontent,whichalsocreatedneedfor newsubpage.>
7.5APPENDIX 7.5.1DoseRateandDecayHeatLimitCompliance 719b 7.6
<Moved
7.6REFERENCES
tonewsubpage.>
Chapters8and9-Nochanges