ML18151A064
| ML18151A064 | |
| Person / Time | |
|---|---|
| Site: | Surry |
| Issue date: | 09/08/1987 |
| From: | Eva Hickey, Jamison J Battelle Memorial Institute, PACIFIC NORTHWEST NATION |
| To: | Testa E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| References | |
| NUDOCS 8709280009 | |
| Download: ML18151A064 (3) | |
Text
l
()Battelle September 8, 1987
- ? C',*
v I
,. O Pacific Northwest Laboratories 1*,.., f.d;~x 999
- Ricfrl.Md, Washington U.S.A. 99352 Telephone (509) 375-3782 Mr. Eldan Testa U~S. Nuclear Regulatory Commission Region* II 101 Marietta Street Suite 3100 Atlanta, GA 30303
. Telex 15-2874
Dear Eldan:
~ c::
- ~
(JJ X
- \\)
CJ1 0
SURRY SCENARIO REVIEW I
l> g Attached are the comments resulting from our review of the subject scenar1,.
The scenario should support a reasonable demonstration of the licensee's ~
Emergency Response capability.
No major deficiencies were noted.
tr The comments are classified as follows:
Major Deficiencies Those which may have a serious negative impact on*
the overall conduct of the exercise - e.g., prevent an adequate demonstration of the licensee's Emer-gency Response capability.
Minor Deficiencies - Those items which, individually, may degrade the demonstration of certain parts of the licensee's capability, but should not significantly detract from the overall success of the exercise.
Other Deficiencies/Questions - Items *such as minor deficiencies or incon-sistencies in scenario data, or matters of clarity which the licensee may wish to examine or explain prior to the exercise.
If you have any questions concerning these comments, please contact me on FTS (509) 375-3782, or Eva Hickey on FTS (509) 375-2065.
Sincerely,
~~~
J. D. Jamison Technical Leader Emergency Preparedness Group Health Physics Technology Section HEALTH PHYSICS DEPARTMENT JDJ/EEH: l em cc:
DB Matthews, w/enclosure g
Eva Eckert Hickey Senior Research Scientist Health Physics Technology Section HEALTH PHYSICS DEPARTMENT I\\\\\\
e SCENARIO REVIEW for e
SURRY EMERGENCY PREPAREDNESS EXERCISE, OCTOBER 8, 1987 Major Deficiencies:
None.
Minor Deficiencies:
- 1.
The Medical Drill Scenario has a victim.that is seriously injured and should be transported immediately to a hospital. There should be no attempt to decontaminate the individual, and even at the hospital, life-saving steps would take priority over health physics concerns.
A less serious apparent injury would better demonstrate the coordinated medical and health physics response objectives.
- 2.
The plant data and messages lack realism and detail in several important respects:
9/8/87 The purpose of scenario message #10 is not clear. It is, in fact, an 11 instruction to players 11 and not an exercise message.
- Scenario message lOA looks more like a 11walkthrough 11 discussion scenario than a message depictihg plant conditions, to which players are supposed to respond.
- Reactor power (neutron power, 0-100%) is not one of the data points provided on the plant data sheets).
The events and conditions of 1555-1605 are not clearly depicted by the data sheets and messages.
If the exercise is to support any evaluation of the operations response to this event (emergency detection, recognition, classification, mitigatibn) the data and messages for this time period must be enhanced in number and detail.
- Message lOD seems out of place in the scena~io and also quite confusing~
This message should be carefully reviewed to make sure that it says what was intended, and. also the time window and conditions under which it is to be issued should be clarified.
On the 1645 plant data sheet the RCS delta-Tis not consistent with the values given for T-Hot T-Cold.
- It is not clear why RVLIS values continue to drop from 1610-1700 when pressure is normal and core exit temperature is well below saturation.
1
e More detailed data concerning the 11A 11 steam generator is needed to allow the operations staff to respond to the event and to provide the-TSC with information from which to compute the source t_erm.
Individual steam generator pressures, feed flows, safety valve positions, MSIV positions and steam-flows should be provided every few minutes while the release is in progress.
Other Deficiencies/Questions:
- 1. It is very unrealistic that there is a hurricane GOming on shore only a hundred miles or so away and the meteorological conditions do not change at all during a 13 hour1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> period!
- 2.
There is a series of particulate and Iodine data in the Section 11 In plant 11 for various locations outside the plant that have no times a~sociated wit~ them.
Sampl~ times should be given for all. data.
- 3.
Under 11Radiological Monitoring Data 11 there is an equation and conversion table for finding CPM from the µCi/ml I-131 equivalence, however, it is not clear where the µCi/ml data is obtained.
11 In Plant 11 data provides a nuclide breakdown, iridicating a more complete analysis than would be possible with an air sample and RM-14.
The 110n-Site 11 and 110ff-Site 11 data provide the appropriate I-131 equivalent activity.
- 4.
General Comment - The exercise is so long and drawn out with little operations action for the first 6-8 hours that the players may have little enthusiasm for participating.
- 5.
The messages reporting the air plane crash at 1345 give the switchyard as the location of the crash. Although the plant data sheets reflect no immediate damage to the incoming power lines, the plant staff will probably want to start diesels and reduce reactor power in anticipation of loss of some offsite power sources. Controllers should be prepared to intervene with realistic information to keep the scenario moving according to the prepared data.
9/8/87 2