7.

PACKAGE OPERATIONS This chapter describes the operating procedures, inspections, tests, and special preparations used in loading and unloading the shipping package. These procedures are in place and utilized for handling the existing package. In all cases, evaluation of the procedures, inspections, etc. have demonstrated the ability of the shipping package to comply with the applicable operating procedure requirements specified in 10 CFR 71, Subpart G. Based on these evaluations, occupational radiation exposures are maintained as low as reasonably achievable, as required by 10 CFR 20.1101(b).

7.1 Package Loading The package is loaded in accordance with Procedures R-2014-G, UNLOADING AND LOADING PROCEDURE FOR USA/9215/B(U) PACKAGE and R-2019-G, MAINTENANCE AND STORAGE PROCEDURE FOR USA/9215/B(U) PACKAGE 7.1.1 Preparation for Loading The package is prepared for loading/unloading in accordance with Procedure R-2014-G. The authorized contents of the package are verified administratively by reviewing applicable source certificates, leak tests, licenses, etc. The package is inspected prior to use for any damage in accordance with Section 8.5 of Procedure R-2014-G. Inspection of gaskets and closure devices are performed in accordance with Procedure R-2019-G Sections 6.1, 6.1.1, 6.1.2, 6.2, 6.3, and 6.4.

7.1.2 Loading of Contents Loading of the S/TC is addressed in Procedure R-2014-G Section 9.1, and 9.2 in addition to operating procedures under applicable NRC and agreement state materials licenses and regulations.

7.1.3 Preparation for Transport The package is prepared for transport in accordance with Procedure R-2014-G section 9 and 10.

USA/9215/B(U) Consolidated Application for Renewal April 2018 Revision 6 Page 7-1

7.2 Package Unloading The S/TC is unloaded in accordance with Procedure R-2014-G, Sections 8 and 9. The S/TC is always handled dry and there is no liquid coolant so special procedures to prevent moisture are not necessary. Visual inspection of the S/TC drum and internal sleeves/shield plugs is performed prior to each use. If solid contaminants were observed, they would be removed prior to source loading.

7.2.1 Receipt of Package from Carrier Receipt ofthe package is addressed in Procedure R-2014-G section 8.

7.2.2 Removal of Contents Removal of the contents is addressed in R-2014-G section 9.

7.3 Preparation of Empty Package for Transport After the source(s) have been unloaded from the S/TC, radiation and contamination surveys are performed in accordance with 49CFR173.443. An EMPTY label is attached to the end cover of the S/TC. The empty S/TC may or may not be placed into the overpack for storage. The overpack and S/TC are stored in a dry area indoors.

7.4 Other Operations Radioactive material shipments in the USA/9215/B(U) package are made in accordance with 10 CFR Part 37.

7.5 Appendix R-2014-G, Revision-2 UNLOADING AND LOADING PROCEDURE FOR USA/9215/B(U) PACKAGE R-2019-G, Revision 2 MAINTENANCE AND STORAGE PROCEDURE FOR USA/9215/B(U) PACKAGE USA/9215/B{U) Consolidated Application for Renewal April 2018 Revision 6 Page 7-2

UNLOADING AND LOADING PROCEDURE FOR USA/9215/B(U) PACKAGE PROCEDURE R-2014-G Revision 2 Effective Date Reviewed for Compliance, Safety and Adequacy for Intended Purpose and Approved Jerry L. F~e, Author: Jerry L. Fogle Date MA-RCH Z:. 9 1 Zo 13

~r=

Edmond J. DeRosa, RSO Field Service Operations Date

_,2q 11/Ck/'c:..4 ~/ 3

~}:!:: f§1IJ Executive Management Date

  • )-_ q MA-i'<.~~ 2'. o l 3 Change Record: This document supersedes Revision 1.

This is a controlled document and as such shall only be modified in accordance with the latest revision of Procedure R-5512, Preparation of Quality System Programs and Procedures - RMT, and Procedure R-5513, Document Control - RMT Not valid for use without a control copy number.

Control Copy No. ___

. UNCONTROLLED DOCUMENT Jhat may become Out... of.n:it~

1. PURPOSE UNLOADING AND LOADING PROCEDURE FOR USA/9215/B(U) PACKAGES Procedure R-2014-G Revision 2 This procedure establishes instructions for routine handling, loading and unloading of USA/9215/B(U) packages in accordance with the Certificate of Compliance, Neutron's Quality Assurance Program for the Transportation of Radioactive Materials, and applicable provisions of 10CFR71, Subpart H.

Note: This is a general procedure applicable to any authorized user and/or facility.

Authorized users/facilities should develop and implement specific procedures, work instructions, and/or other documents covering aspects of implementation which are specific to their operations.

2. SCOPE 2.1 This procedure applies only to USA/9215/B(U} packages at hot cells and field operations sites.

2.2 Transferring radioactive sources between a transfer cask and a therapy or irradiation unit is within the scope of the licensee's operating license and is not.

covered under this procedure.

3. DEFINITIONS AND ABBREVIATIONS ALARA:

C of C:

C of CA:

OP:

QAMRT:

QAP:

RPP:

RSO:

As low as reasonably achievable per 10CFR 20.1003 Certificate of Compliance, USN RC Certificate of Competent Authority, USDOT Overpack-steel and wooden protective jacket portion of the package Quality Assurance Manager Radioactive Transportation Quality Assurance Program Radiation Protection Program Radiation Safety Officer, or qualified designee, of the shipper of record if RSO is used alone. Other RSO positions are specifically designated in the procedure Control Copy No. ___ _

UNCONTROLLED DOCUMENT That may become Out-of-Date.

Unloading and Loading Procedure for USA/9215/B(U) Packages R-2014-G, Rev. 2 Page 3 of 9 Shipper of Record:

Licensee who delivers licensed material to a carrier for transport TC:

USDOT:

Transfer cask, lead-steel inner portion of the package United States Department of Transportation USNRC:

Unites States Nuclear Regulatory Commission

4. REFERENCES Certificate of Compliance and Certificate of Competent Authority - USA/9215/B(U)

QAP R-2019-G, Maintenance and Storage Procedure for USA/9215/B{U) Package USDOT regulations 49CFR172 and 49CFR173 USNRC regulations 10CFR20 and 10CFR71

5. QUALIFICATION AND RESPONSIBILITIES 5.1 Personnel shall be qualified and trained in accordance with the applicable QAP and RPP to perform their assigned responsibilities for operations conducted in accordance with this proced~re.

5.2 The QAMRT is responsible for evaluating reports of damage to packages and consulting with executive management on plans of action to address the problem.

5.3 The RSO, or qualified designee, shall be responsible for administering the applicable RPP, as it applies to the use of the USA/9215/B(U) package.

5.4 Hot cell operations 5.4.1 The authorized hot cell manager, or qualified designee, is responsible for al! operations conducted in the hot cell including verification that the source(s) to be loaded are authorized for loading.by the C of C and the verification and documentation of the identity of sources.

5.4.2 Hot cell operators report to the authorized hot cell manager and are responsible for loading and unloading sources acting under the authority of the authorized hot cell manager, RSO, or their qualified designee.

Control Copy No. __ _

UNCONTROLLED DOCUMENT That may become

Unloading and Loading Procedure for USA/9215/B(U) Packages R-2014-G, Rev. 2 Page 4 of 9 5.5 Field operations Qualified personnel are responsible for receiving, shipping, unloading, and loading shipping packages in accordance with the C of C and applicable regulations.

6.

SAFETY AND SECURITY

7.
8.

All procedures, regulations, security measures and precautions associated with the handling of radioactive materials shall be followed.

EQUIPMENT REQUIREMENTS 7.1 As appropriate, tools, gauges, measuring and testing devices shall be controlled, calibrated and adjusted in accordance with the requirements of 10CFR71.125 and the applicable QAP.

7.2 Maintenance and calibration of all radiation and contamination monitoring equipment shall be in accordance with the RPP and QAP, or other documented program.

7.3 Tools and equipment for hot cell and/or field operations are specified in documents not covered under this procedure and are therefore approved under the applicable RPP or QAP.

RECEIPT OF PACKAGES 8.1 Receipt of packages shall be scheduled by the RSO, or qualified designee, and packages shall be received in accordance with 10CFR 20.1906.

8.2 Survey the package. If radiation levels are not within the limits specified in 10CFR71.47:

Notify the RSO and the RSO of the receiving licensee of the situation; The RSO shall immediately notify the carrier and the NRC Operations office as required by 10CFR 20.1906; the parties shall work to resolve the situation; and, No packages shall be left unsecured and unattended during the receiving process.

Control Copy No. __ _

. UNCONTROLLED DOCUMENT That may become

Unloading and Loading Procedure for USA/9215/B(U)Packages R-2014-G, Rev. 2 Page 5 of9 8.3 If the radiation levels are within the limits as specified in 10CFR71.47, remove the package from the transport vehicle if necessary or desirable for unloading the TC from the OP.

8.4 If the package contains radioactive material, verify that the seal is unbroken. If the seal is broken or if there is no seal, notify the RSO and proceed according to his or her instructions.

8.5 Visually inspect the package for damage in accordance with R-2019-G. If the package appears damaged, notify the QAMRT and proceed according to his or her instructions, including a plan of action to wipe test the package as necessary and notify the RSO of the receiving licensee.

8.6 As appropriate for the mechanism by which the lid is to be removed, remove the plate, cover and/or bolts that render inoperable the lid lifting eye, lifting bale or lid cover bolt holes.

8.7 Remove the metal lid nuts and bolts and save these fasteners for shipping the package at a later time. Remove the metal lid from the OP.

8.8 Remove the nuts from the wooden lid and save for shipping the package at a later time. Remove the wooden lid from the OP.

8.9 Ensure that the cask lifting bale is securely attached by the 2 nuts and bolts supplied with the package.

8.10 Remove the TC from the OP and inspect both for damage in accordance with R-2019-G. Notify the QAMRT of any damage found. Use the package for further shipments only with the approval of the QAMRT. Replace both OP lids as necessary when the empty package is left outside during use of the TC.

8.11 Move the TC to a safe location within the receiving facility as soon as practical in accordance with all security measures in place at the time of receipt. Do not leave the TC unattended unless secured in a locked room provided and approved by the receiving facility.

Control Copy No. __ _

UNCONTROLLED DOCUMENT Jhat may become I"\\ **,....., n""',h.

Unloading and Loading Procedure for USA/9215/B(U) Packages R-2014-G, Rev. 2 Page 6 of 9

9.

UNLOADING/LOADING OF SOURCES FROM/INTO THE TC Operations involving the transfers of radioactive material utilizing the transfer cask shall be performed in accordance with NRC or agreement state operating licenses specific to the proposed plan of work. In addition to authorized users of the package, hot cell operations may also be performed, in conjunction with Neutron Products, Inc., by a licensee approved by Neutron's RSO, Field Service Operations, but who is not itself an authorized user of the package. Handling, leak test, and wipe tests shall be performed in accordance with procedures and regulatory requirements of the hot cell licensee.

9.1 Source(s), sleeves, plugs and/or shields shall be unloaded and/or loaded into the TC in accordance with all requirements of the C of C and the specific task to be performed.

9.2 Verify that the gasket surfaces have not been damaged during source handling or unloading operations. If any gasket is damaged, notify Neutron's OAMRT in accordance with the latest revision of R-2019-G.

9.3 The cask end covers shall be secured with the bolts and tightened to 100-125 inch/pounds.

9.4 Decontaminate the external surfaces of the TC to contamination levels in accordance with 49CFR173.443 and which are as low as practical in accordance with AlARA and the hot cell licensee procedure.

9.5 The TC shall be inspected for damage in accordance with the latest revision of R-2019-G and prepared for shipment in accordance with Section 10.

10.

LOADING THE TC INTO THE OP 10.1 Survey the TC and place appropriate Yellow II or Yellow Ill labels on end covers to serve as an indicator of the radioactive hazard present during movement of the TC to the OP for shipment.

10.2 Visually inspect the TC and OP assembly and lids before loading the TC in the OP in accordance with Attachment A, Visual Inspection Checklist for USA/9215/B(U)

Packages, or equivalent, and document the results for shipping records. If any damages are found, notify Neutron's QAMRT in accordance with the latest revision of R-2019-G and do not use the package for shipments of radioactive material without approval of Neutron's QAMRT.

Control Copy No. __ _

UNCONTROLLED DOCUMENT That may become f'\\ **,1, -.£. l"'\\_JI

Unloading and Loading Procedure for USA/9215/B(U) Packages R-2014-G, Rev. 2 Page 7 of 9 Note: No package shall be left unattended during the loading process, and shipment shall be made as soon as practical in accordance with the security measures in place at the shipping site/facility.

10.3 Load the TC into the OP, and install the wood and steel lids, securing the lids with the fasteners removed during unloading. If any fasteners are lost, missing or damaged, notify Neutron's QAMRT in accordance with the latest revision of R-2019-G.

10.4 Visually inspect the assembled package in accordance with checklist in Attachment A, or equivalent, to ensure that the package satisfies all requirements of the C of C.

10.5 Render the lid lifting eye inoperable for lifting the package.

10.6 If a lid lifting bale is used instead of the lifting eye, remove the lid lifting bale before shipping the package and install 4 nuts and bolts in the holes to render the holes inoperable for lifting.

10.7 Decontaminate the outside of the package to levels in accordance with 49CFR173.443 and which are as low as practical in accordance with Al.ARA, as necessary.

10.8 Prepare and affix the appropriate labels for the shipment in accordance with 49CFR172.403.

10.9 Install a tamper indicating seal and record the results on the visual inspection checklist, Attachment A, or equivalent.

10.10 The package shall be loaded onto the transport vehicle and a radiation survey performed in accordance with the applicable requirements of 10CFR71.47 and 49CFR173.441. If dose rates exceed the regulatory requirements, the RSO shafl be notified and the situation corrected.

11.

RECORDS Records shall be captured and retained by the RSO in accordance with 10CFR71.91.

Control Copy No. __ _

, UNCONTROLLED DOCUMENT Jhat may become r,....

Unloading and Loading Procedure for USA/9215/B(U) Packages R-2014-G, Rev. 2 Page 8 of9

12.

CHANGE RECORD Cover page Revision 2 Added RSO, Field Service Operations as reviewer Section 3 Added QAMRT and QAP, and clarified RSO positions Section 4 Removed reference to USA/9102/B() C of C which has expired Removed reference to ANSI specification for leak testing sources Section 5 Added QAM RT and responsibilities Added hot cell and field operations personnel and responsibilities Section 6 Added security measures in listed actions Section 7 Added tools and equipment for hot cell and field operations to clarify applicability to appropriate programs and/or procedures Section 8 Rewritten to include receiving packages only Section 9 New - for unloading and loading of the TC at hot cell and field operation sites Section 10 New - for loading and shipping the package only Section 11 New-for records Section 12 New-for change record Appendix A Added for parts specified on package components Attachment A Visual inspection checklist, or equivalent - sample Control Copy No. __ _

, UNCONTROLLED DOCUMENT That may become Ont.. nf.. n~tA.

Unloading and Loading Procedure for USA/9215/B(U) Packages R-2014-G, Rev. 2 Page 9 of 9 APPENDIX A

1.

The following parts shall be used for the maintenance of the TC:

Bolt-hex head cap screw 1/2-13 X 1 1/4 inch long, Grade 8 steel per Item 71, Drawing 240122 Gasket - Silicon rubber, 1/16 inch thick, ASTM D-2000-80, per Item 47, Drawing 240122 Identification tag-per Item 49, Drawing 240122

2.

The following parts shall be used for the maintenance of the OP:

Threaded rod -5/8 inch UNC steel threaded rod, 41 1/4 inch long nominal per Drawing 240116, View D Nut for wooden protective jacket - 5/8 inch UNC steel nut per Drawing 240116, ViewD Washer for wooden protective jacket - 5/8 inch steel flat washer per Drawing 240116, View D Hex nut for wooden protective jacket-5/8 inch UNC steel hex nut per Drawing 240116, View D Plywood sheet for wooden protective jacket-3/4 inch nominal plywood sheet per Drawing 240116, Section F-F Screw for outer steel shell -Grade 5, steel hex head cap screw, 1/2-13 X 1 inch long per Drawing 240116, Section A-A Nut for outer steel shell - Grade 5, steel hex nut, 1/2-13 per Drawing 240116, Section A-A Control Copy No. __ _

UNCONTROLLED DOCUMENT Jhat may become Out*of.. QatGi

MAINTENANCE AND STORAGE PROCEDURE FOR USA/9215/B(U) PACKAGE PROCEDURE R-2019-G

. Revision 2 Effective Date MA--f It; 2.ol '3.

Reviewed for Compliance, Safety, and Adequacy of Intended Purpose and Approve Jerry L Fog;, Mfff Date MA-lcC+l 2'1 20l 3 Edmond J. DeRosa, RSO Date ;?£ ~

,;b/3'

~

William L. Ransoho#

Executive Management Date

).. q M A-f.2.,:_H ;;lo l 7 Principal Author: Jerry L. Fogle Change Recor~.~ This document supersedes Revision 1 This is a controlled document and as such shall only be modified in accordance with the latest revision of Procedure R-5512, Preparation of Quality System Programs and Procedures - RMT, and Procedure R-5513, Document Control - RMT.

\\_3/4.

~::,.....------------------~

Not valid for use without a control copy number Control Copy No. ___ _

I UNCONTROLLED DOCUMENT That may become Out-of-Date.

1. PURPOSE MAINTENANCE AND STORAGE PROCEDURE FOR USA/9215/B{U) PACKAGE Procedure R-2019-G Revision 2 This procedure sets forth the maintenance and storage program for Neutron Products' radioactive materials shipping packaging in accordance with applicable requirements of the Certificate of Compliance (C of C), Neutron's Quality Assurance Program {QAP) and 10CFR71, Subpart H.
2. SCOPE 2.1 This procedure applies to Neutron Products' shipping packaging Model Number NPl-20WC-6, Mkll Certificate of Compliance and Certificate of Competent Authority USA/9215/B(U)).

2.2 All package maintenance shall be performed in accordance with the latest revision of C of C USA/9215/B(U).

3. DEFINITIONS AND ABBREVIATIONS CofC:

CofCA:

OP:

Permanent Site:

QAMRT:

QAP:

RMT:

Certificate of Compliance USA/9215/B(U}, USN RC Certificate of Competent Authority USA/9215/B(U), US DOT Overpack, steel and wood protective jacket portion of the packaging Neutron's facilities, a hot cell or source manufacturing facility authorized to load and unload packaging covered under this procedure Quality Assurance Manager Radioactive Transportation Quality Assurance Program for the Transportation of Radioactive Materials, Neutron Products, Inc.

Radioactive Materials Transportation Control Copy No. ___

UNCONTROLLED DOCUMENT That may become Out*of-Oate..

Procedure R-2019-G Maintenance and Storage Procedure For USA/9215/B(U) Package Revision 2 Page 3 of 9 RPP:

S/CI:

TC:

Temporary Job site:

USDOT:

USNRC:

4. REFERENCES Radiation Protection Program Suspect/Counterfeit items Transfer cask1 lead-steel inner portion of the packaging A field site where Neutron or other personnel are working in accordance with Neutron's field service license or a license held by others.

United States Department of Transportation United States Nuclear Regulatory Commission Certificate of Compliance USA/9215/B{U), USN RC Quality Assurance Program for the Transportation of Radioactive Materials, Neutron Products, Inc.

USN RC regulations - 10CFR71, Subparts A through H S. PERSONNEL 5.1 Personnel shall be qualified and trained in accordance with the applicable QAP and RPP to perform their assigned responsibilities for operations conducted in accordance with this procedure.

5.2 Personnel have the responsibility and obligation to halt operations deemed to be unsafe or not in compliance with applicable regulations. In addition, personnel shall report to Neutron's QAMRT any inspection findings that identify damage to package components, or parts which need to be replaced.

5.3 All replacement of parts and any required repairs shall only be performed by Neutron, or with approval of Neutron's QAMRT.

5.4 Personnel shall be knowledgeable and trained on S/CI detection and prevention in a manner consistent with the user's QAP.

Control Copy No. __

UNCONlROLLE:u OUCUMENT That may become n, 11* -"I.n111to

Procedure R-2019-G Maintenance and Storage Procedure For USA/9215/B(U) Package Revision 2 Page 4 of 9

6. MAINTENANCE 6.1 Each shipment - General Inspection Requirements for all Package Components 6.1.1 All closures and fasteners shall be visually inspected to the extent possible without dismantling the packaging further than required to load the source and ship the package. Neutron's QAMRT shall be notified of any fasteners requiring replacement, so that Neutron can furnish conforming fasteners prior to the next package use.

6.1.2 Any damage to the TC, Outer Steel Shell or Wooden Protective Jacket, except for superficial defects such as marks, dents or scratches, shall be reported to Neutron's QAMRT {see section 5.2) for evaluation in accordance with section 6.5, Nonconformances.

6.2 Each Shipment - TC In addition to the requirements of section 6.1 above, confirm that gaskets have been replaced in the prior 18 months. Whenever the end covers are installed or removed, visually inspect the two gaskets and all of the gasket surfaces on the TC for any damage including cracking of the gaskets. Normal marking of the gasket surfaces is not to be considered as damage.

6.3 Each Shipment - Wooden Protective Jacket In addition to the requirements of section 6.1 above, without dismantling the packaging further than required to load and ship the package, the individual responsible for the shipment shall inspect the portions of the wooden protective jacket that are visually accessible for:

Control Copy No. __

Loss of plywood bonding; Cracks; Water logging; Corrosion of the steel rods; Warping of the steel rods that cause the cover not to fit and cannot be corrected by bending the rods by hand without the application of heat; and, Functional status of all closures and fasteners.

UNCONTROLLED DOCUMENT That may become

.t"\\ - _,L

- £ n - ;....

Procedure R-2019-G Maintenance and Storage Procedure For USA/9215/B(U) Package Revision 2 Page 5 of 9 6.4 Each Shipment-Outer Steel Shell and Assembled Package In addition to the requirements of section 6.1 above:

The portions of the outer steel shell of the OP which are accessible without dismantling the packaging further than required to load and ship the package shall be visually inspected for any damage:

After receipt of a shipment at a permanent or temporary job site;

and, Prior to the next use of the OP.

After source loading, the assembled package, containing radioactive material, shall be visually inspected for any damage prior to shipment.

6.5 Nonconformances When a report of damage or nonconformance is received, Neutron's QAMRT shall evaluate the condition of the package in accordance with the QAP and the package shall not be shipped until the:

111 Damage is determined not to impair the ability of the packaging to meet required performance specifications; or, Packaging is repaired in accordance with the QAP; and, QAMRT has determined that the package is in conformance with all requirements of the C of C.

6.6 Periodic Packaging Inspection and Maintenance 6.6.1 TCs are to be inspected at a frequency not to exceed 18 months and OPs are to be inspected at a frequency not to exceed 12 months.

6.6.2 Maintenance, as necessary, includes:

Control Copy No. __

111 Painting of the package components; Replacing waterproof coverings on vent holes; Inspection and/or replacement of the threaded rods in the wooden protective jackets; UNCONTROLLED DOCUMENT That may become JP.,_ -* L -

Procedure R-2019-G Maintenance and Storage Procedure For USA/9215/B{U) Package Revision 2 Page 6 of 9 Replacement of gaskets, regardless of condition, no less often than every 18 months; Replacement of fasteners; Replacement of up to three layers of wood in the wooden protective jacket in accordance with written procedures; Inspection, and/or replacement of permanent I. D. tags, durable marking signs and holders, and radiation symbol plates; fnspection, and/or replacement of lid lifting chains, brackets or bale covers; and e

Welding or steel repair of tears and/or damage to the outer steel shell in accordance with Neutron's QAP.

Note: Any repairs made to packaging components shall be made in accordance with all requirements of the C of C for the package and any parts replaced shall be in accordance with Appendix A.

6.6.3 Each wooden protective jacket shall be weighed annually. !f the weight gain or loss exceeds 10 pounds, it shall be reported to the QAMRT for evaluation and the OP shall be taken out of service until the QAMRT determines that performance of the OP has not been compromised or that the wooden protective jacket is repaired in accordance with the QAP.

6.6.4 Maintenance shall be performed by qualified employees and/or vendors approved in accordance with the QAP.

6.6.5 Packages which have been delayed outside the United States, may be shipped after the inspection due date for any package component has passed provided that:

The package was prepared for shipment in accordance with this procedure by a qualified individual; Since being prepared for shipment, the package was stored in a manner consistent with this procedure; and, Upon return to the United States, the package is unloaded and inspected according to this procedure prior to any subsequent use.

Control Copy No. __

UNCONTROLLED DOCUMENT Jhat may become t"\\ut_l\\f... n~+c

Procedure R-2019-G Maintenance and Storage Procedure For USA/9215/B(U) Package Revision 2 Page 7 of 9 6.7 Packaging Fabrication In accordance with 10CFR71.19, no new packaging for the C of C shall be fabricated.

7. PACKAGING STORAGE AND HANDLING Proper storage and handling is considered a component of the package maintenance program.

7.1 All packaging components {when not in use, in-transit, or in the control of others) shall be stored inside a building within a dry area.

7.2 All package components shall be handled and lifted with appropriate capacity equipment. No packaging components shall be pushed with a forklift using any sidewalls as the point of contact with the forks of the lift truck.

7.3 No assembled package shall be lifted with the lid lifting eye by any lifting device.

7.4 Replacement parts for package components shall be handled and stored in accordance with the QAP.

8. RECORDS 8.1 The Manager, Radioactive Shipping Packages shall capture and maintain records of all packaging periodic inspections, maintenance and repairs.

8.2 Records of periodic inspections, maintenance and repairs shall be retained for a period not less than three years beyond the date the C of C for the package has expired or activities have ceased under the OAP.

9. CHANGE RECORD Cover page Revision 2, new effective date New signature block for Executive Management review Global Removed reference to corrective action, including procedure R-5514, Corrective and Preventive Action - RMT, not applicable to this procedure Control Copy No.__

. UNCONTROLLED DOCUMENT Jhat may become

Procedure R-2019-G Maintenance and Storage Procedure For USA/9215/B(U) Package Revision 2 Page 8 of 9 Section 2 Removed applicability to C of C USA/9102B { ) which has expired Section 4 Removed references not in procedure Section 5.2 Added requirement that Neutron's QAMRT be notified in the event of package damage Section 6 Rearranged substantially Clarified replacement of fasteners and other parts, specified frequency or as necessary Section 6.5 Added for Nonconformances Section 6.6.5 Added to allow for return shipment of packaging when package components are past inspection/maintenance due dates Section 7 New, addressing storage and handling Section 8.2 Revised, clarifying retention requirements of records Control Copy No. __

UNCONTROLLED DOCUMENT That may become Out-nf -Oat A,.

Procedure R-2019-G Maintenance and Storage Procedure For USA/9215/B(U) Package Revision 2 Page 9 of9 APPENDIX A

1.

The following parts shall be used for the maintenance of the TC:

Bolt-hex head cap screw 1/2-13 X 1 1/4 inch long, Grade 8 steel per Item 71, Drawing 240122 Gasket-Silicon rubber, 1/16 inch thick, ASTM D-2000-80, per Item 47, Drawing 240122 Identification tag-per Item 49, Drawing 240122

2.

The following parts shall be used for the maintenance of the OP:

Threaded rod - 5/8 inch UNC steel threaded rod, 41 1/4 inch long nominal per Drawing 240116, View D Nut for woqden protective jacket - 5/8 inch UNC steel nut per Drawing 240116, ViewD Washer for wooden protective jacket-5/8 inch steel flat washer per Drawing 240116, View D Hex nut for wooden protective jacket - 5/8 inch UNC steel hex nut per Drawing 240116, View D Plywood sheet for wooden protective jacket-3/4 inch nominal plywood sheet per Drawing 240116, Section F-F Screw for outer steel shell-Grade 5, steel hex head cap screw, 1/2-13 X 1 inch long per Drawing 240116, Section A-A Nut for outer steel shell - Grade 5, steel hex nut, 1/2-13 per Drawing 240116, Section A-A Control Copy No. __

. UNCONTROLLED DOCUMENT That may become l"\\n **-"'-n"'""'