Proposed Tech Spec 4.7.1.5 & Table 2.2-5 Allowing Continued Use of 8 MSIV Stroke Time During 10th Fuel Cycle
ML18095A733
Person / Time
Site: Salem PSEG icon.png
Issue date: 02/01/1991
From:
Public Service Enterprise Group
To:
Shared Package
ML18095A732 List:
References
NUDOCS 9102080144
Download: ML18095A733 (3)


Text

'.

0 TABLE 3.3-5 (Continued~

ENGINEERED SAFETY FEATURES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION RESPONSE TIME IN SECONDS

3.

Pressurizer Pressure-I.ow

4.
a.

Safety Injection (ECCS)

b.

Reactor Trip (from SI)

c.

Feedwater Isolation

d.

Containment Isolation - Phase "A"

e.
f.
g.

Containment Ventilation Isolation Auxiliary Feedwater Pumps Service Water System Differential Pressure Betwee.n Steam Lines-High

a.
b.
c.
d.

Safety Inj action (ECCS')

Reactor Trip (from SI)

Feedwater Isolation Containment Isolation - Phase ~A"

e.

Containment Ventilation Isolation

f.
g.

Service Water System

5.

Steam Flow in Two Steam Lines - High Coincident with Tavg -- Low-Low

a.
b.
c.
d.
e.
f.
g.
h.

Safety InJection (ECCS)

Reactor Trip (from SI)

Feedwater Isolation Containment Isolation - Phase "A" Containment Ventilation Isolation Auxiliary Feedwater Pumps Service Water System St.eam Line Isolation s 21.0<1>;12.0< 2>

s 2.0 s 7.0 s 18.0<2>

Not Applicable

< 60

~ 49.0<1> ;13.'0°< 2>

s ~2.0<

2 >;22.0<

3 >

s 2.0 s 7.0 s ~17.-0 ( 2.> /2 7. 0 ( 3)

Not Applicable s 60 s 13.0<2>/48.0< 3>

s 15.75<2>;25,75< 3>

s 5.75 s 10.75 s 20.15< 2>;30.15< 3>

Not. Applicable s 61.75 s 15.75<2>;50.15< 3>

s 10.75 Sl3.75 until restart following t~ta refueling outage.

SALEM - UNIT 1 3/4 3-28 Amendment No. 112

"t TABLE 3.3-5 (Continue~

ENGINEERED SAFETY FEATURES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION RESPONSE TIME IN SECONDS

6.

Steam Flow in Two Steam Lines-High Coincident with Steam Line Pressure - Low

a.
b.
c.
d.
e.

Safety Injection (ECCS)

Reactor Trip (from SI)

Feedwater Isolation Containment Isolation-Phase "A" Containment Ventilation Isolation

f.

0 Auxiliary Feedwater Pumps

g.

Service ~at~r System

h. * *. Steam Line IsOlatfon
7.

Containment Pressur~--High-High

a.

Containment Spray b.*

Containment Isolation-Phase "B".

c.

Steam Line Isolation

d.
  • C9ntainment Fan Cooler
8.

Steam Generator Water Level--High-High

a.
b.

Turbine Trip Feedwater Isolation

9.

Steam Generator Water Level--Low-Low

a.

Motor-Driven Auxiliary_ *:Feed~ater Pumps(4)

b.

Turbine-Driven Auxiliary Feedwater Pumps(5) s 12.0<2);22.0< 3) s 2.0 s 7.0 s 17.0<2);21.0<3)

Not Applicable s 60.*

s 14.~~ 2 )/48.0( 3 )

s 8.0 s ~5.0 Not Applicable s 7.0 s 40.0.

s 2.5 s 11.0*

s 60.0 s 60.0 lte£+h I SlO.O seconds until restart following the ~*refueling outage.

SALEM - UNIT 1 3/4 3-29 Amendment No. 112

0 PLANT SYSTEMS

APPLICABILITY: MODES 1, 2 and 3.

ACTION; MODES 1 - With one main steam line isolation valve inoperable, POWER OPERATION may continue provided the inoperable valve is either restored to OPERABLE status or closed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />; otherwise, be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />..

MODES 2 - With one main steam line isolation ~alve inoperable, and 3 sub~equent operation in MODES 1, 2 or 3 may proceeA:provided;

. a.

The isolation valve h maintained closed.

b.

The. provisions of Specification 3.0.4 ar~n6t applicable.

Otherwise, be in HOT SHUTDOWN within. the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.7.l\\S Each main steam line isolation v1lve shall be demonstrated OPERABLE by verifying full closure within 5 seconds when tested pursuant to o Specification 4.0.5.

8 seconds until restart following t!e!a!s~ refueling outage.

SALEM - UNIT 1 3/4 7-10 Amendment No. 112