ML18068A064

From kanterella
Jump to navigation Jump to search

Relief from the Requirements of the ASME Code Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019)
ML18068A064
Person / Time
Site: Surry  Dominion icon.png
Issue date: 03/26/2018
From: Cotton K
Plant Licensing Branch II
To: Stoddard D
Virginia Electric & Power Co (VEPCO)
Cotton K, NRR/DORL/LPL2-1, 415-1438
References
CAC MF8987, CAC MF8988, EPID L-2016-LLR-0019
Download: ML18068A064 (4)


Text

OFFICIAL USE ONLY PROPRIETARY INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Daniel G. Stoddard Senior Vice President and Chief Nuclear Officer Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711 March 26, 2018

SUBJECT:

SURRY POWER STATION, UNIT NOS. 1 AND 2 - RELIEF FROM THE REQUIREMENTS OF THE ASME CODE REPAIR/REPLACEMENT OF BURIED CIRCULATING AND SERVICE WATER CLASS 3 PIPING WITH CARBON FIBER REINFORCED POLYMER (CAC NOS. MF8987 AND MF8988; EPID L-2016-LLR-0019)

Dear Mr. Stoddard:

By letter dated December 14, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16355A346), as supplemented by letters dated February 23 and August 31, 2017 (ADAMS Accession Nos. ML17055C360 and ML17251A864, respectively),

Virginia Electric and Power Company (the licensee) proposed an alternative to the requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code,Section XI IWA-4000. The licensee proposed to apply layers of carbon fiber reinforced polymer to repair the inside surface of buried circulating water and service water piping at Surry Power Station, Units 1 and 2.

By letter dated December 20, 2017 (ADAMS Accession No. ML17303A037), the NRC authorized relief for the subject request. The safety evaluation (SE) was issued in both proprietary and non-proprietary versions. Four numbers in the Allowable Stress Design Methodology Summary table on page 28 and 29 of the proprietary version of the relief request SE are incorrect. The correction resulted from a data transfer error on the part of the NRC.

The correct page is reissued as enclosed. This change does not impact the NRC safety conclusion, as described in its safety evaluation or the no significant hazards consideration as published in the Federal Register.

Please note that this information is proprietary, and is not a part of the nonproprietary version of the issued safety evaluation (ADAMS Accession No. ML17303A068).

The Enclosure to this letter contains sensitive unclassified non-safeguards information.

When separated from the Enclosure, this document is DECONTROLLED.

OFFICIAL USE ONLY PROPRIETARY INFORMATION

D. Stoddard OFFICIAL USf ONbY PROPRIETARY INFORMATION-If you have any questions, please contact me at (301) 415-1438, or via email at Karen.Cotton@nrc.gov.

Docket Nos. 50-280 and 50-281 cc: Listserv

~. *-*~ - ~'

Sincerely, Karen Cotton, Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation OFFICIAL USE ONLY PROPRIETARY INFORMATION

OFFICIAL USE ONLY PROPRIETARY INFORMATION CORRECTION TO PAGES 28 AND 29 OF ISSUED PROPRIETARY SAFETY EVALUATION (ML17303A037)

SURRY POWER STATION, UNIT NOS. 1 AND 2 RELIEF FROM THE REQUIREMENTS OF THE ASME CODEREPAIR/REPLACEMENT OF BURIED CIRCULATING AND SERVICE WATER CLASS 3 PIPING WITH CARBON FIBER REINFORCED POLYMER (CAC NOS. MF8987 AND MF8988; EPID L-2016-LLR-0019)

OFFICIAL USE ONLY PROPRIETARY INFORMATION

OFFICIAL USE ONLY PROPRIETARY INFORMATION

SUBJECT:

SURRY POWER STATION, UNIT NOS. 1 AND 2 - RELIEF FROM THE REQUIREMENTS OF THE ASME CODE REPAIR/REPLACEMENT OF BURIED CIRCULATING AND SERVICE WATER CLASS 3 PIPING WITH CARBON FIBER REINFORCED POLYMER (CAC NOS. MF8987 AND MF8988; EPID L-2016-LLR-0019) DATED MARCH 26, 2018 DISTRIBUTION:

PUBLIC RidsAcrs_MailCTR Resource RidsNrrDorllpl2-1 Resource RidsNrrLAKGoldstein Resource RidsNrrPMSurry Resource RidsRgn2MailCenter Resource ADAMS A ccess1on N p

o:

ropnetary: ML18068A020 N

P on ropnetary:

OFFICE DORL/LPL2-1/PM DORL/LPL2-1 /LA DORL/LPL2-1/BC NAME KCotton KGoldstein MMarkley DATE 3/23/18 3/15/18 3/26/18 OFFICIAL RECORD COPY OFFICIAL USE ONLY PROPRIETARY INFORMATION ML18068A064 DORL/LPL2-1 /PM KCotton 3/26/18