ML18038B061
| ML18038B061 | |
| Person / Time | |
|---|---|
| Issue date: | 12/31/2017 |
| From: | Couret I L Office of Public Affairs |
| To: | |
| Meyd, Donald | |
| Shared Package | |
| ML18038B330 | List:
|
| References | |
| NUREG 1350 V29 R01 | |
| Download: ML18038B061 (62) | |
Text
87This edition of the Digest provides a snapshot of data; for the most current information and data collection, please visit the NRC Web site Dataset Index Web page at https://www.nrc.gov/reading-rm/doc-collections/datasets/.
88Abbreviations ABWR advanced boiling-water reactor AC Allis Chalmers ac alternating current ACRS Advisory Committee on Reactor Safeguards ADR Alternative Dispute Resolution AEC Atomic Energy Commission (U.S.)
AEP American Electric Power Company AGN solid homogeneous core (Aerojet-General Nucleonics)
AP1000 Advanced Passive 1000 Megawatt (Westinghouse pressurized-water reactor)ASLB Atomic Safety and Licensing Board B&R Burns & Roe B&W Babcock & Wilcox BALD Baldwin Associates BECH BechtelBRRT Brown & Root BWR boiling-water reactor CE Combustion Engineering CFR Code of Federal Regulations Co company COL combined license Comm. Op. date of commercial operationCon Type containment typeDRYAMB dry, ambient pressureDRYSUB dry, subatmospheric ICECND wet, ice condenser MARK I wet, Mark I MARK II wet, Mark II MARK III wet, Mark III CP Issued date of construction permit issuance CT computerized tomography CVP civil penalties CWE Commonwealth Edison Company DANI Daniel International DBDB Duke & Bechtel DBT design-basis threat DC design certi~cation DHS Department of Homeland Security (U.S.)DOE Department of Energy (U.S.)
DOT Department of Transportation (U.S.)DUKE Duke Power Company EBSO Ebasco EIA Energy Information Administration (DOE)
EP emergency preparednessEPA Environmental Protection Agency (U.S.)EPR Evolutionary Power Reactor EPZ emergency planning zone ESBWR Economic Simpli~ed Boiling-Water Reactor ESP early site permit EVESR ESADA (Empire States Atomic Development Associates)
Vallecitos Experimental Superheat Reactor Exp. Date expiration date of operating
license FBR fast breeder reactor FEMA Federal Emergency Management
Agency FERC Federal Energy Regulatory
Commission FLUR Fluor Pioneer FOIA Freedom of Information Act FTE full-time equivalent FW Foster Wheeler FY ~scal year G&H Gibbs & Hill GA General Atomics GCR gas-cooled reactor GE General Electric GEH General Electric-Hitachi Nuclear Energy GEIS generic environmental impact statement GETR General Electric Test Reactor GIL Gilbert Associates GL general license GPC Georgia Power Company GWh gigawatt-hour(s) HLW high-level waste HTG high-temperature gas (reactor)
HWR heavy-water reactor IAEA International Atomic Energy Agency INES International Nuclear Event Scale ISFSI independent spent fuel storage installation ISR in situ recovery IUP Intergrated University Program KAIS Kaiser Engineers kW kilowatt(s)
LLP B&W lowered loopLLW low-level radioactive waste LMFB liquid metal fast breeder (reactor)
LR Issued license renewal issuedLWGR light-water-cooled graphite-moderated reactor MOX mixed oxide MW megawatt(s)MWe megawatt(s) electric MWh megawatt-hour(s)
MWt megawatt(s) thermal NIAG Niagara Mohawk Power Corporation NEA Nuclear Energy Agency NMMSS Nuclear Materials Management and Safeguards System NOV notice of violation NRC Nuclear Regulatory Commission (U.S.)
89 Alabama AL Alaska AK Arizona AZ Arkansas ARCalifornia CA Colorado CO Connecticut CTDelaware DE District of Columbia DC Florida FL Georgia GA Guam GU Hawaii HI Idaho ID Illinois IL Indiana IN Iowa IA Kansas KS Kentucky KY Louisiana LA Maine ME Maryland MD Massachusetts MA Michigan MI Minnesota MN Mississippi MS Missouri MO Montana MT Nebraska NE Nevada NVNew Hampshire NH New Jersey NJ New Mexico NMNew York NYNorth Carolina NC North Dakota ND Ohio OH Oklahoma OK Oregon OR Pennsylvania PA Puerto Rico PR Rhode Island RISouth Carolina SC South Dakota SDTennessee TNTexas TX Utah UTVermont VTVirgin Islands VIVirginia VAWashington WA West Virginia WV Wisconsin WI Wyoming WY NSP Northern States Power Company NSSS nuclear steam system supplier and design type GE 2 GE Type 2 GE 3 GE Type 3 GE 4 GE Type 4 GE 5 GE Type 5 GE 6 GE Type 6 WEST 2LP Westinghouse Two-Loop WEST 3LP Westinghouse Three-Loop WEST 4LP Westinghouse Four-Loop NSTS National Source Tracking System OECD Organisation for Economic Co-operation and Development OIG Of~ce of the Inspector General OL operating license OL Issued date of latest full power operating license PG&E Paci~c Gas & Electric Company PHWR pressurized heavy water reactor PRA probabilistic risk assessment PSEG Public Service Electric and Gas Company PWR pressurized-water reactor RLP B&W raised loop ROP Reactor Oversight ProcessRTR research and test reactor S&L Sargent & Lundy S&W Stone & Webster SCF sodium-cooled fast (reactor)
SDP signi~cance determination process SI Systme Internationale (d'unités) (International System of Units)
SL severity level SMR small modular reactor SOARCA State-of-the-Art Reactor
Consequence Analysis SSI Southern Services Incorporated
STP South Texas Project TMI-2 Three Mile Island, Unit 2 Sv sievert TRIGA Training Reactor and Isotopes Production, General AtomicsTVA Tennessee Valley Authority UNSCEAR United Nations Scienti~c Committee on the Effects of
Atomic Radiation UE&C United Engineers & Constructors US-APWR U.S. [version of] Advanced Pressurized-Water Reactor VBWR Vallecitos Boiling-Water Reactor WDCO Westinghouse Development Corporation
WEST Westinghouse Electric WNA World Nuclear AssociationState and Territory Abbreviations 90SPACE AND TIME Quantity From Inch-Pound Units To Metric Units Multiply by Length mi (statute) km 1.609347 yd m *0.9144 ft (int) m *0.3048 in cm *2.54Area mi 2 km 2 2.589998 acre m 2 4,046.873 yd 2 m 2 0.8361274 ft 2 m 2 *0.09290304 in 2 cm 2 *6.4516Volume acre foot m 3 1,233.489 yd 3 m 3 0.7645549 ft 3 m 3 0.02831685 ft 3 L 28.31685 gal L 3.785412 oz mL 29.57353 in 3 cm 3 16.38706Velocity mi/h km/h 1.609347 ft/s m/s *0.3048 Acceleration ft/s 2 m/s 2 *0.3048 NUCLEAR REACTION AND IONIZING RADIATION Quantity From Inch-Pound Units To Metric Units Multiply by Activity (of a radionuclide) curie (Ci)
MBq *37,000.0 dpm becquerel (Bq) 0.016667 Absorbed dose rad gray (Gy) *0.01 rad cGy (centigray)
- 1.0 Dose equivalent rem sievert (Sv)
- 0.01 rem mSv *10.0 mrem mSv *0.01 mrem µSv (microsievert)
- 10.0Exposure roentgen (R)
C (coulomb)/kg 0.000258 (x-rays and gamma rays)QUICK-REFERENCE METRIC CONVERSION TABLESHEAT Quantity From Inch-Pound Units To Metric Units Multiply by Thermodynamic
°F K *K = (°F + 459.67)/1.8 temperatureCelsius temperature
°F °C *°C = (°F - 32)/1.8 Linear expansion 1/°F 1/K or 1/°C
- 1.8 coef~cient
Thermal conductivity (Btu
- in)/(ft 2
- h * °F)
W/(m * °C) 0.1442279Coef~cient of heat Btu/(ft 2
- h * °F)
W/(m 2 * °C) 5.678263 transfer Heat capacity Btu/°F kJ/°C 1.899108 Speci~c heat capacity Btu/(lb * °F) kJ/(kg * °C)
- 4.1868 91QUICK-REFERENCE METRIC CONVERSION TABLESEntropy Btu/°F kJ/°C 1.899108Speci~c entropy Btu/(lb * °F) kJ/(kg * °C)
- 4.1868Speci~c internal Btu/lb kJ/kg *2.326 energy MECHANICS Quantity From Inch-Pound Units To Metric Units Multiply by Mass (weight) ton (short) t (metric ton)
- 0.90718474 lb (avdp) kg *0.45359237 Moment of mass lb
- ft kg
- m 0.138255 Density ton (short)/yd 3 t/m 3 1.186553 lb/ft 3 g/m 3 16.01846 Concentration (mass) lb/gal g/L 119.8264 Momentum lb
- ft/s kg
- m/s 0.138255 Angular momentum lb
- ft 2/s kg
- m 2/s 0.04214011 Moment of inertia lb
- ft 2 kg
- m 2 0.04214011Force kip (kilopound) kN (kilonewton) 4.448222 lbf N (newton) 4.448222Moment of force, torque lbf
- ft N
- m 1.355818 lbf
- in N
- m 0.1229848Pressure atm (std) kPa (kilopascal)
- 101.325 bar kPa *100.0 lbf/in 2 (formerly psi) kPa 6.894757 inHg (32 °F) kPa 3.38638 ftH 2 O (39.2 °F) kPa 2.98898 inH 2 O (60 °F) kPa 0.24884 mmHg (0 °C) kPa 0.133322Stress kip/in 2 (formerly ksi)
MPa 6.894757 lbf/in 2 (formerly psi)
MPa 0.006894757 lbf/in 2 (formerly psi) kPa 6.894757 lbf/ft 2 kPa 0.04788026Energy, work kWh MJ *3.6 cal th J (joule) *4.184 Btu kJ 1.055056 ft
- lbf J 1.355818 therm (U.S.)
MJ 105.4804 Power Btu/s kW 1.055056 hp (electric) kW *0.746 Btu/h W 0.2930711* Exact conversion factorsNotes: The information contained in this table is intended to familiarize readers with commonly used International System of Units (SI) units and provide a quick reference to aid understanding of documents containing SI units. The conversion factors listed here have not been approved as NRC guidelines for the development of licensing actions, regulations, or policy.To convert from metric units to inch-pound units, divide the metric unit by the conversion factor.
Sources: Federal Standard 376B, "Preferred Metric Units for General Use by the Federal Government," and International Commission on Radiation Units and Measurements, ICRU Report 33, "Radiation Quantities and Units," issued 1980.HEAT (continued) 92 Arkansas Nuclear One, Unit 1 IV PWR-DRYAMB 2,568 12/06/1968 87Entergy Operations, Inc. B&W LLP DPR-51 05/21/1974 102 London, AR BECH 12/19/1974 56 (6 miles WNW of Russellville, AR)
BECH 06/20/2001 98 05000313 05/20/2034 82https://www.nrc.gov/info-~nder/reactors/ano1.html 72 Arkansas Nuclear One, Unit 2 IV PWR-DRYAMB 3,026 12/06/1972 90Entergy Operations, Inc. CE NPF-6 09/01/1978 93 London, AR BECH 03/26/1980 91 (6 miles NW of Russellville, AR)
BECH 06/30/2005 85 05000368 07/17/2038 94https://www.nrc.gov/info-~nder/reactors/ano2.html 89Beaver Valley Power Station, Unit 1 I PWR-DRYAMB 2,900 06/26/1970 101FirstEnergy Nuclear Operating Co. WEST 3LP DPR-66 07/02/1976 92Shippingport, PA S&W 10/01/1976 86(17 miles W of McCandless, PA)
S&W 11/05/2009 86 05000334 01/29/2036 90https://www.nrc.gov/info-~nder/reactors/bv1.html 91 Beaver Valley Power Station, Unit 2 I PWR-DRYAMB 2,900 05/03/1974 102FirstEnergy Nuclear Operating Co. WEST 3LP NPF-73 08/14/1987 91Shippingport, PA S&W 11/17/1987 97(17 miles W of McCandless, PA)
S&W 11/05/2009 98 05000412 05/27/2047 90https://www.nrc.gov/info-~nder/reactors/bv2.html 97 Braidwood Station, Unit 1 III PWR-DRYAMB 3,645 12/31/1975 101 Exelon Generation Co., LLC WEST 4LP NPF-72 07/02/1987 91 Braceville, IL S&L 07/29/1988 95 (20 miles SSW of Joliet, IL) CWE N/A 103 05000456 10/17/2026 93https://www.nrc.gov/info-~nder/reactors/brai1.html 90 Braidwood Station, Unit 2 III PWR-DRYAMB 3,645 12/31/1975 93 Exelon Generation Co., LLC WEST 4LP NPF-77 05/20/1988 93 Braceville, IL S&L 10/17/1988 98 (20 miles SSW of Joliet, IL) CWE N/A 96 05000457 12/18/2027 91https://www.nrc.gov/info-~nder/reactors/brai2.html 95Browns Ferry Nuclear Plant, Unit 1 II BWR-MARK 1 3,458 05/10/1967 91Tennessee Valley Authority GE 4 DPR-33 12/20/1973 88 Athens (Limestone County), AL TVA 08/01/1974 94 (32 miles W of Huntsville, AL) TVA 05/04/2006 90 05000259 12/20/2033 94https://www.nrc.gov/info-~nder/reactors/bf1.html 83 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 93Browns Ferry Nuclear Plant, Unit 2 II BWR-MARK 1 3,458 05/10/1967 80Tennessee Valley Authority GE 4 DPR-52 06/28/1974 99 Athens (Limestone County), AL TVA 03/01/1975 79 (32 miles W of Huntsville, AL) TVA 05/04/2006 98 05000260 06/28/2034 85https://www.nrc.gov/info-~nder/reactors/bf2.html 94Browns Ferry Nuclear Plant, Unit 3 II BWR-MARK 1 3,458 07/31/1968 87Tennessee Valley Authority GE 4 DPR-68 07/02/1976 83 Athens (Limestone County), AL TVA 03/01/1977 89 (32 miles W of Huntsville, AL) TVA 05/04/2006 88 05000296 07/02/2036 92https://www.nrc.gov/info-~nder/reactors/bf3.html 80 Brunswick Steam Electric Plant, Unit 1 II BWR-MARK 1 2,923 02/07/1970 100Duke Energy Progress, LLC GE 4 DPR-71 09/08/1976 77 Southport, NC UE&C 03/18/1977 92 (30 miles S of Wilmington, NC) BRRT 06/26/2006 89 05000325 09/08/2036 93https://www.nrc.gov/info-~nder/reactors/bru1.html 83 Brunswick Steam Electric Plant, Unit 2 II BWR-MARK 1 2,923 02/07/1970 79Duke Energy Progress, LLC GE 4 DPR-62 12/27/1974 98 Southport, NC UE&C 11/03/1975 73 (30 miles S of Wilmington, NC) BRRT 06/26/2006 98 05000324 12/27/2034 81https://www.nrc.gov/info-~nder/reactors/bru2.html 92Byron Station, Unit 1 III PWR-DRYAMB 3,645 12/31/1975 88 Exelon Generation Co., LLC WEST 4LP NPF-37 02/14/1985 88Byron, IL S&L 09/16/1985 96(17 miles SW of Rockford, IL) CWE N/A 97 05000454 10/31/2024 88https://www.nrc.gov/info-~nder/reactors/byro1.html 97Byron Station, Unit 2 III PWR-DRYAMB 3,645 12/31/1975 93 Exelon Generation Co., LLC WEST 4LP NPF-66 01/30/1987 94Byron, IL S&L 08/02/1987 86(17 miles SW of Rockford, IL) CWE N/A 94 05000455 11/06/2026 94https://www.nrc.gov/info-~nder/reactors/byro2.html 86 Callaway Plant, Unit 1 IV PWR-DRYAMB 3,565 04/16/1976 90 Union Electric Co.
WEST 4LP NPF-30 10/18/1984 103 Fulton, MO BECH 12/19/1984 77(25 miles ENE of Jefferson City, MO) DANI 03/06/2015 89 05000483 10/18/2044 96https://www.nrc.gov/info-~nder/reactors/call.html 87 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 94Calvert Cliffs Nuclear Power Plant, Unit 1 I PWR-DRYAMB 2,737 07/07/1969 101Calvert Cliffs Nuclear Power Plant, LLC CE DPR-53 07/31/1974 81 Exelon Generation Co., LLC BECH 05/08/1975 97Lusby, MD BECH 03/23/2000 91 (40 miles S of Annapolis, MD) 07/31/2034 97 05000317 89https://www.nrc.gov/info-~nder/reactors/calv1.html Calvert Cliffs Nuclear Power Plant, Unit 2 I PWR-DRYAMB 2,737 07/07/1969 92Calvert Cliffs Nuclear Power Plant, LLC CE DPR-69 08/13/1976 101 Exelon Generation Co., LLC BECH 04/01/1977 81Lusby, MD BECH 03/23/2000 100 (40 miles S of Annapolis, MD) 08/13/2036 86 05000318 95https://www.nrc.gov/info-~nder/reactors/calv2.html Catawba Nuclear Station, Unit 1 II PWR-ICECND 3,411 08/07/1975 89Duke Energy Carolinas, LLC WEST 4LP NPF-35 01/17/1985 89York, SC DUKE 06/29/1985 96 (18 miles S of Charlotte, NC) DUKE 12/05/2003 86 05000413 12/05/2043 88https://www.nrc.gov/info-~nder/reactors/cat1.html 97 Catawba Nuclear Station, Unit 2 II PWR-ICECND 3,411 08/07/1975 101Duke Energy Carolinas, LLC WEST 4LP NPF-52 05/15/1986 92York, SC DUKE 08/19/1986 86 (18 miles S of Charlotte, NC) DUKE 12/05/2003 100 05000414 12/05/2043 86https://www.nrc.gov/info-~nder/reactors/cat2.html 88 Clinton Power Station, Unit 1 III BWR-MARK 3 3,473 02/24/1976 93 Exelon Generation Co., LLC GE 6 NPF-62 04/17/1987 100 Clinton, IL S&L 11/24/1987 82 (23 miles SSE of Bloomington, IL)
BALD N/A 97 05000461 09/29/2026 87https://www.nrc.gov/info-~nder/reactors/clin.html 89 Columbia Generating Station IV BWR-MARK 2 3,486 03/19/1973 50Energy Northwest GE 5 NPF-21 04/13/1984 97Benton County, WA B&R 12/13/1984 80(12 miles NW of Richland, WA) BECH 05/22/2012 98 05000397 12/20/2043 78https://www.nrc.gov/info-~nder/reactors/wash2.html 92 Comanche Peak Nuclear Power Plant, Unit 1 IV PWR-DRYAMB 3,612 12/19/1974 91 Vistra Operating Co., LLC WEST 4LP NPF-87 04/17/1990 98 Glen Rose, TX G&H 08/13/1990 94(40 miles SW of Fort Worth, TX)
BRRT N/A 85 05000445 02/08/2030 100https://www.nrc.gov/info-~nder/reactors/cp1.html 92 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 95 Comanche Peak Nuclear Power Plant, Unit 2 IV PWR-DRYAMB 3,612 12/19/1974 92 Vistra Operating Co., LLC WEST 4LP NPF-89 04/06/1993 91 Glen Rose, TX BECH 08/03/1993 99(40 miles SW of Fort Worth, TX)
BRRT N/A 93 05000446 02/02/2033 88https://www.nrc.gov/info-~nder/reactors/cp2.html 100 Cooper Nuclear Station IV BWR-MARK 1 2,419 06/04/1968 86 Nebraska Public Power District GE 4 NPF-46 01/18/1974 87Brownville, NE B&R 07/01/1974 97(23 miles S of Nebraska City, NE)
B&R 11/29/2010 88 05000298 01/18/2034 97https://www.nrc.gov/info-~nder/reactors/cns.html 84 Davis-Besse Nuclear Power Station, Unit 1 III PWR-DRYAMB 2,817 03/24/1971 81FirstEnergy Nuclear Operating Co.
B&W RLP NFP-3 04/22/1977 91Oak Harbor, OH BECH 07/31/1978 95(21 miles ESE of Toledo, OH) B&W 12/08/2015 74 05000346 04/22/2037 97https://www.nrc.gov/info-~nder/reactors/davi.html 79 Diablo Canyon Nuclear Power Plant, Unit 1 IV PWR-DRYAMB 3,411 4/23/1968 100 Paci~c Gas & Electric Co. WEST 4LP DPR-80 11/02/1984 84Avila Beach, CA PG&E 05/07/1985 95 (12 miles SW of San Luis Obispo, CA) PG&E N/A 87 05000275 11/02/2024 87https://www.nrc.gov/info-~nder/reactors/diab1.html 98 Diablo Canyon Nuclear Power Plant, Unit 2 IV PWR-DRYAMB 3,411 12/09/1970 89 Paci~c Gas & Electric Co. WEST 4LP DPR-82 08/26/1985 97Avila Beach, CA PG&E 03/13/1986 82 (12 miles SW of San Luis Obispo, CA) PG&E N/A 86 05000323 08/26/2025 95https://www.nrc.gov/info-~nder/reactors/diab2.html 88 Donald C. Cook Nuclear Plant, Unit 1 III PWR-ICECND 3,304 03/25/1969 87 Indiana Michigan Power Co. WEST 4LP DPR-58 10/25/1974 104 Bridgman, MI AEP 08/28/1975 78(13 miles S of Benton Harbor, MI)
AEP 08/30/2005 94 05000315 10/25/2034 78https://www.nrc.gov/info-~nder/reactors/cook1.html 82 Donald C. Cook Nuclear Plant, Unit 2 III PWR-ICECND 3,468 03/25/1969 104 Indiana Michigan Power Co. WEST 4LP DPR-74 12/23/1977 91 Bridgman, MI AEP 07/01/1978 85(13 miles S of Benton Harbor, MI)
AEP 08/30/2005 101 05000316 12/23/2037 79https://www.nrc.gov/info-~nder/reactors/cook2.html 71 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 96 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent)Dresden Nuclear Power Station, Unit 2 III BWR-MARK 1 2,957 01/10/1966 95 Exelon Generation Co., LLC GE 3 DPR-19 02/20/1991 A 104 Morris, IL S&L 06/09/1970 85 (25 miles SW of Joliet, IL) UE&C 10/28/2004 98 05000237 12/22/2029 83https://www.nrc.gov/info-~nder/reactors/dres2.html 91Dresden Nuclear Power Station, Unit 3 III BWR-MARK 1 2,957 10/14/1966 99 Exelon Generation Co., LLC GE 3 DPR-25 01/12/1971 91 Morris, IL S&L 11/16/1971 89 (25 miles SW of Joliet, IL) UE&C 10/28/2004 95 05000249 01/12/2031 89https://www.nrc.gov/info-~nder/reactors/dres3.html 84Duane Arnold Energy Center III BWR-MARK 1 1,912 06/22/1970 99NextEra Energy Duane Arnold, LLC GE 4 DPR-49 02/22/1974 83 Palo, IA BECH 02/01/1975 89 (8 miles NW of Cedar Rapids, IA)
BECH 12/16/2010 79 05000331 02/21/2034 88https://www.nrc.gov/info-~nder/reactors/duan.html 79 Edwin I. Hatch Nuclear Plant, Unit 1 II BWR-MARK 1 2,804 09/30/1969 98Southern Nuclear Operating Co.
GE 4 DPR-57 10/13/1974 89Baxley, GA BECH 12/31/1975 94 (20 miles S of Vidalia, GA) GPC 01/15/2002 89 05000321 08/06/2034 101https://www.nrc.gov/info-~nder/reactors/hat1.html 93 Edwin I. Hatch Nuclear Plant, Unit 2 II BWR-MARK 1 2,804 12/27/1972 78Southern Nuclear Operating Co., Inc. GE 4 NPF-5 06/13/1978 98Baxley, GA BECH 09/05/1979 89 (20 miles S of Vidalia, GA) GPC 01/15/2002 99 05000366 06/13/2038 91https://www.nrc.gov/info-~nder/reactors/hat2.html 101 Fermi, Unit 2 III BWR-MARK 1 3,486 09/26/1972 94 DTE Electric Company GE 4 NPF-43 07/15/1985 54 Newport, MI S&L 01/23/1988 62(25 miles NE of Toledo, OH) DANI N/A 82 05000341 03/20/2025 69https://www.nrc.gov/info-~nder/reactors/ferm2.html 86 A: The Atomic Energy Commission (AEC) issued a provisional Operating License (OL) on 12/22/1969, allowing commercial operation. The NRC issued a full-term OL on 02/20/1991.
97 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent)Grand Gulf Nuclear Station, Unit 1 IV BWR-MARK 3 4,408 09/04/1974 94Entergy Operations, Inc. GE 6 NPF-29 11/01/1984 70 Port Gibson, MS BECH 07/01/1985 86(20 miles S of Vicksburg, MS) BECH N/A 82 05000416 11/01/2024 93https://www.nrc.gov/info-~nder/reactors/gg1.html 47 H.B. Robinson Steam Electric Plant, Unit 2 II PWR-DRYAMB 2,339 04/13/1967 100Duke Energy Progress, Inc. WEST 3LP DPR-23 07/31/1970 85 Hartsville, SC EBSO 03/07/1971 85(26 miles NW of Florence, SC) EBSO 04/19/2004 86 05000261 07/31/2030 85https://www.nrc.gov/info-~nder/reactors/rob2.html 95Hope Creek Generating Station, Unit 1 I BWR-MARK 1 3,840 11/04/1974 103PSEG Nuclear, LLC GE 4 NPF-57 07/25/1986 93 Hancocks Bridge, NJ BECH 12/20/1986 80 (18 miles SE of Wilmington, DE)
BECH 07/20/2011 102 05000354 04/11/2046 83https://www.nrc.gov/info-~nder/reactors/hope.html 85 Indian Point Nuclear Generating, Unit 2 I PWR-DRYAMB 3,216 10/14/1966 98Entergy Nuclear Indian Point 2, LLC WEST 4LP DPR-26 09/28/1973 90 Buchanan, NY UE&C 08/01/1974 77(24 miles N of New York, NY) WDCO N/A 93 05000247 09/28/2013 77https://www.nrc.gov/info-~nder/reactors/ip2.html 53 Indian Point Nuclear Generating, Unit 3 I PWR-DRYAMB 3,216 08/13/1969 90Entergy Nuclear Indian Point 3, LLC WEST 4LP DPR-64 12/12/1975 100 Buchanan, NY UE&C 08/30/1976 94(24 miles N of New York, NY) WDCO N/A 98 05000286 12/12/2015 86https://www.nrc.gov/info-~nder/reactors/ip3.html 102 James A. FitzPatrick Nuclear Power Plant I BWR-MARK 1 2,536 05/20/1970 97Entergy Nuclear FitzPatrick, LLC GE 4 DPR-59 10/17/1974 84 Scriba, NY S&W 07/28/1975 89 (6 miles NE of Oswego, NY) S&W 09/08/2008 79 05000333 10/17/2034 96https://www.nrc.gov/info-~nder/reactors/~tz.html 76 Joseph M. Farley Nuclear Plant, Unit 1 II PWR-DRYAMB 2,775 08/16/1972 101Southern Nuclear Operating Co.
WEST 3LP NPF-2 06/25/1977 91 Columbia, AL SSI 12/01/1977 90 (18 miles E of Dothan, AL) DANI 05/12/2005 102 05000348 06/25/2037 86https://www.nrc.gov/info-~nder/reactors/far1.html 86 98 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent)Joseph M. Farley Nuclear Plant, Unit 2 II PWR-DRYAMB 2,775 08/16/1972 89Southern Nuclear Operating Co.
WEST 3LP NPF-8 03/31/1981 104 Columbia, AL SSI 07/30/1981 91 (18 miles E of Dothan, AL) BECH 05/12/2005 89 05000364 03/31/2041 98https://www.nrc.gov/info-~nder/reactors/far2.html 90 LaSalle County Station, Unit 1 III BWR-MARK 2 3,546 09/10/1973 101 Exelon Generation Co., LLC GE 5 NPF-11 04/17/1982 97 Marseilles, IL S&L 01/01/1984 95 (11 miles SE of Ottawa, IL) CWE 10/19/2016 93 05000373 04/17/2042 99https://www.nrc.gov/info-~nder/reactors/lasa1.html 89 LaSalle County Station, Unit 2 III BWR-MARK 2 3,546 09/10/1973 96 Exelon Generation Co., LLC GE 5 NPF-18 12/16/1983 103 Marseilles, IL S&L 10/19/1984 88 (11 miles SE of Ottawa, IL) CWE 10/19/2016 95 05000374 12/16/2043 83https://www.nrc.gov/info-~nder/reactors/lasa2.html 95 Limerick Generating Station, Unit 1 I BWR-MARK 2 3,515 06/19/1974 96 Exelon Generation Co., LLC GE 4 NPF-39 08/08/1985 85Limerick, PA BECH 02/01/1986 101(21 miles NW of Philadelphia, PA)
BECH N/A 91 05000352 10/26/2024 100https://www.nrc.gov/info-~nder/reactors/lim1.html 93 Limerick Generating Station, Unit 2 I BWR-MARK 2 3,515 06/19/1974 90 Exelon Generation Co., LLC GE 4 NPF-85 08/25/1989 95Limerick, PA BECH 01/08/1990 94(21 miles NW of Philadelphia, PA)
BECH N/A 99 05000353 06/22/2029 89https://www.nrc.gov/info-~nder/reactors/lim2.html 101McGuire Nuclear Station, Unit 1 II PWR-ICECND 3,411 02/23/1973 94Duke Energy Carolinas, LLC WEST 4LP NPF-9 07/08/1981 105 Huntersville, NC DUKE 12/01/1981 82 (17 miles N of Charlotte, NC) DUKE 12/05/2003 82 05000369 06/12/2041 95https://www.nrc.gov/info-~nder/reactors/mcg1.html 89McGuire Nuclear Station, Unit 2 II PWR-ICECND 3,411 02/23/1973 91Duke Energy Carolinas, LLC WEST 4LP NPF-17 05/27/1983 82 Huntersville, NC DUKE 03/01/1984 95 (17 miles N of Charlotte, NC) DUKE 12/05/2003 94 05000370 03/03/2043 87https://www.nrc.gov/info-~nder/reactors/mcg2.html 97 99 Millstone Power Station, Unit 2 I PWR-DRYAMB 2,700 12/11/1970 87 Dominion Nuclear Connecticut, Inc. CE DPR-65 09/26/1975 83Waterford, CT BECH 12/26/1975 95 (3.2 miles SW of New London, CT)
BECH 11/28/2005 85 05000336 07/31/2035 85https://www.nrc.gov/info-~nder/reactors/mill2.html 93 Millstone Power Station, Unit 3 I PWR-DRYSUB 3,650 08/09/1974 87 Dominion Nuclear Connecticut, Inc. WEST 4LP NPF-49 01/31/1986 100Waterford, CT S&W 04/23/1986 87 (3.2 miles SW of New London, CT)
S&W 11/28/2005 87 05000423 11/25/2045 97https://www.nrc.gov/info-~nder/reactors/mill3.html 83 Monticello Nuclear Generating Plant, Unit 1 III BWR-MARK 1 2,004 06/19/1967 69Northern States Power Company-Minnesota GE 3 DPR-22 01/09/1981 B 101 Monticello, MN BECH 06/30/1971 50 (30 miles NW of Minneapolis, MN)
BECH 11/08/2006 78 05000263 09/08/2030 78https://www.nrc.gov/info-~nder/reactors/mont.html 93 Nine Mile Point Nuclear Station, Unit 1 I BWR-MARK 1 1,850 04/12/1965 84 Nine Mile Point Nuclear Station, LLC GE 2 DPR-63 12/26/1974 C 87 Scriba, NY NIAG 12/01/1969 88 (6 miles NE of Oswego, NY) S&W 10/31/2006 98 05000220 08/22/2029 88https://www.nrc.gov/info-~nder/reactors/nmp1.html 96 Nine Mile Point Nuclear Station, Unit 2 I BWR-MARK 2 3,988 06/24/1974 95 Nine Mile Point Nuclear Station, LLC GE 5 NPF-69 07/02/1987 83 Scriba, NY S&W 03/11/1988 99 (6 miles NE of Oswego, NY) S&W 10/31/2006 87 05000410 10/31/2046 100https://www.nrc.gov/info-~nder/reactors/nmp2.html 92 North Anna Power Station, Unit 1 II PWR-DRYSUB 2,940 02/19/1971 78Virginia Electric & Power Co. WEST 3LP NPF-4 04/01/1978 89Mineral (Louisa County), VA S&W 06/06/1978 89(40 miles NW of Richmond, VA)
S&W 03/20/2003 100 05000338 04/01/2038 91https://www.nrc.gov/info-~nder/reactors/na1.html 89 North Anna Power Station, Unit 2 II PWR-DRYSUB 2,940 02/19/1971 76Virginia Electric & Power Co. WEST 3LP NPF-7 08/21/1980 99Mineral (Louisa County), VA S&W 12/14/1980 85(40 miles NW of Richmond, VA)
S&W 03/20/2003 92 05000339 08/21/2040 99https://www.nrc.gov/info-~nder/reactors/na2.html 87 B: The AEC issued a provisional OL on 09/08/1970, allowing commercial operation. The NRC issued a full-term OL on 01/09/1981.
C: The AEC issued a provisional OL on 08/22/1969, allowing commercial operation. The NRC issued a full-term OL on 12/26/1974.
APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 100 Oconee Nuclear Station, Unit 1 II PWR-DRYAMB 2,568 11/06/1967 79Duke Energy Carolinas, LLC B&W LLP DPR-38 02/06/1973 90 Seneca, SC DBDB 07/15/1973 91(30 miles W of Greenville, SC) DUKE 05/23/2000 91 05000269 02/06/2033 96https://www.nrc.gov/info-~nder/reactors/oco1.html 83 Oconee Nuclear Station, Unit 2 II PWR-DRYAMB 2,568 11/06/1967 93Duke Energy Carolinas, LLC B&W LLP DPR-47 10/06/1973 102 Seneca, SC DBDB 09/09/1974 82(30 miles W of Greenville, SC) DUKE 05/23/2000 101 05000270 10/06/2033 89https://www.nrc.gov/info-~nder/reactors/oco2.html 98 Oconee Nuclear Station, Unit 3 II PWR-DRYAMB 2,568 11/06/1967 103Duke Energy Carolinas, LLC B&W LLP DPR-55 07/19/1974 86 Seneca, SC DBDB 12/16/1974 97(30 miles W of Greenville, SC) DUKE 05/23/2000 92 05000287 07/19/2034 97https://www.nrc.gov/info-~nder/reactors/oco3.html 91Oyster Creek Nuclear Generating Station I BWR-MARK 1 1,930 12/15/1964 98 Exelon Generation Co., LLC GE 2 DPR-16 07/02/1991 D 88Forked River, NJ B&R 12/23/1969 106(9 miles S of Toms River, NJ) B&R 04/08/2009 90 05000219 04/09/2029 109https://www.nrc.gov/info-~nder/reactors/oc.html 95 Palisades Nuclear Plant III PWR-DRYAMB 2,565.4 03/14/1967 96Entergy Nuclear Operations, Inc.
CE DPR-20 02/21/1991 E 74 Covert, MI BECH 12/31/1971 85 (5 miles S of South Haven, MI) BECH 01/17/2007 86 05000255 03/24/2031 89https://www.nrc.gov/info-~nder/reactors/pali.html 99Palo Verde Nuclear Generating Station, Unit 1 IV PWR-DRYAMB 3,990 05/25/1976 83 Arizona Public Service Company CE 80-2L NPF-41 06/01/1985 100Wintersburg, AZ BECH 01/28/1986 85 (50 miles W of Phoenix, AZ) BECH 04/21/2011 90 05000528 06/01/2045 94https://www.nrc.gov/info-~nder/reactors/palo1.html 83Palo Verde Nuclear Generating Station, Unit 2 IV PWR-DRYAMB 3,990 05/25/1976 91 Arizona Public Service Company CE80-2L NPF-51 04/24/1986 90Wintersburg, AZ BECH 09/19/1986 91 (50 miles W of Phoenix, AZ) BECH 04/21/2011 90 05000529 04/24/2046 85https://www.nrc.gov/info-~nder/reactors/palo2.html 95 D: The AEC issued a provisional OL on 04/09/1969, allowing commercial operation. The NRC issued a full-term OL on 07/02/1991.
E: The AEC issued a provisional OL on 03/24/1971, allowing commercial operation. The NRC issued a full-term OL on 02/21/1991.
APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 101Palo Verde Nuclear Generating Station, Unit 3 IV PWR-DRYAMB 3,990 05/25/1976 97 Arizona Public Service Company CE80-2L NPF-74 11/25/1987 88Wintersburg, AZ BECH 01/08/1988 79 (50 miles W of Phoenix, AZ) BECH 04/21/2011 101 05000530 11/25/2047 85https://www.nrc.gov/info-~nder/reactors/palo3.html 85 Peach Bottom Atomic Power Station, Unit 2 I BWR-MARK 1 3,514 01/31/1968 101 Exelon Generation Co., LLC GE 4 DPR-44 10/25/1973 88Delta, PA BECH 07/05/1974 100(17.9 miles S of Lancaster, PA) BECH 05/07/2003 88 05000277 08/08/2033 99https://www.nrc.gov/info-~nder/reactors/pb2.html 96 Peach Bottom Atomic Power Station, Unit 3 I BWR-MARK 1 3,514 01/31/1968 90 Exelon Generation Co., LLC GE 4 DPR-56 07/02/1974 103Delta, PA BECH 12/23/1974 85(17.9 miles S of Lancaster, PA) BECH 05/07/2003 103 05000278 07/02/2034 75https://www.nrc.gov/info-~nder/reactors/pb3.html 95 Perry Nuclear Power Plant, Unit 1 III BWR-MARK 3 3,758 05/03/1977 79FirstEnergy Nuclear Operating Co.
GE 6 NPF-58 11/13/1986 92Perry, OH GIL 11/18/1987 73 (35 miles NE of Cleveland, OH)
KAIS N/A 96 05000440 03/18/2026 83https://www.nrc.gov/info-~nder/reactors/perr1.html 91 Pilgrim Nuclear Power Station I BWR-MARK 1 2,028 08/26/1968 85Entergy Nuclear Operations, Inc.
GE 3 DPR-35 06/08/1972 98 Plymouth, MA BECH 12/01/1972 74 (38 miles SE of Boston, MA) BECH 05/29/2012 97 05000293 06/08/2032 85https://www.nrc.gov/info-~nder/reactors/pilg.html 92 Point Beach Nuclear Plant, Unit 1 III PWR-DRYAMB 1,800 07/19/1967 79NextEra Energy Point Beach, LLC WEST 2LP DPR-24 10/05/1970 100Two Rivers, WI BECH 12/21/1970 84 (13 miles NW of Manitowoc, WI)
BECH 12/22/2005 90 05000266 10/05/2030 92https://www.nrc.gov/info-~nder/reactors/poin1.html 86 Point Beach Nuclear Plant, Unit 2 III PWR-DRYAMB 1,800 07/25/1968 67NextEra Energy Point Beach, LLC WEST 2LP DPR-27 03/08/1973 F 89Two Rivers, WI BECH 10/01/1972 93 (13 miles NW of Manitowoc, WI)
BECH 12/22/2005 90 05000301 03/08/2033 94https://www.nrc.gov/info-~nder/reactors/poin2.html 86F: AEC issued a provisional OL on 11/18/1971. The NRC issued a full-term OL on 03/08/1973.
APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 102 Prairie Island Nuclear Generating Plant, Unit 1 III PWR-DRYAMB 1,677 06/25/1968 91Northern States Power Co.-Minnesota WEST 2LP DPR-42 04/05/1974 G 81Welch, MN FLUR 12/16/1973 90 (28 miles SE of Minneapolis, MN)
NSP 06/27/2011 84 05000282 08/09/2033 77https://www.nrc.gov/info-~nder/reactors/prai1.html 81 Prairie Island Nuclear Generating Plant, Unit 2 III PWR-DRYAMB 1,677 06/25/1968 99Northern States Power Co.-Minnesota WEST 2LP DPR-35 10/29/1974 74Welch, MN FLUR 12/21/1974 59 (28 miles SE of Minneapolis, MN)
NSP 06/27/2011 101 05000306 10/29/2034 65https://www.nrc.gov/info-~nder/reactors/prai2.html 78 Quad Cities Nuclear Power Station, Unit 1 III BWR-MARK 1 2,957 02/15/1967 92 Exelon Generation Co., LLC GE 3 DPR-29 12/14/1972 102Cordova, IL S&L 02/18/1973 85 (20 miles NE of Moline, IL) UE&C 10/28/2004 103 05000254 12/14/2032 83https://www.nrc.gov/info-~nder/reactors/quad1.html 92 Quad Cities Nuclear Power Station, Unit 2 III BWR-MARK 1 2,957 02/15/1967 104 Exelon Generation Co., LLC GE 3 DPR-30 12/14/1972 92Cordova, IL S&L 03/10/1973 91 (20 miles NE of Moline, IL) UE&C 10/28/2004 90 05000265 12/14/2032 95https://www.nrc.gov/info-~nder/reactors/quad2.html 85 R.E. Ginna Nuclear Power Plant I PWR-DRYAMB 1,775 04/25/1966 84 R.E. Ginna Nuclear Power Plant, LLC WEST 2LP DPR-18 09/19/1969 90 Ontario, NY GIL 07/01/1970 93(20 miles NE of Rochester, NY) BECH 05/19/2004 91 05000244 09/18/2029 89https://www.nrc.gov/info-~nder/reactors/ginn.html 94 River Bend Station, Unit 1 IV BWR-MARK 3 3,091 03/25/1977 90Entergy Nuclear Operations, Inc.
GE 6 NPF-47 11/20/1985 91 St. Francisville, LA S&W 06/16/1986 84 (24 miles NW of Baton Rouge, LA)
S&W N/A 96 05000458 08/29/2025 76https://www.nrc.gov/info-~nder/reactors/rbs1.html 78 St. Lucie Plant, Unit 1 II PWR-DRYAMB 3,020 07/01/1970 85 Florida Power & Light Co. CE DPR-67 03/01/1976 72 Jensen Beach, FL EBSO 12/21/1976 74(10 miles SE of Ft. Pierce, FL) EBSO 10/02/2003 101 05000335 03/01/2036 83https://www.nrc.gov/info-~nder/reactors/stl1.html 68G: AEC issued a provisional OL on 08/09/1973. The NRC issued a full-term OL on 04/05/1974.
APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 103 St. Lucie Plant, Unit 2 II PWR-DRYAMB 3,020 05/02/1977 66 Florida Power & Light Co. CE NPF-16 06/10/1983 68 Jensen Beach, FL EBSO 08/08/1983 91(10 miles SE of Ft. Pierce, FL) EBSO 10/02/2003 82 05000389 04/06/2043 77https://www.nrc.gov/info-~nder/reactors/stl2.html 85 Salem Nuclear Generating Station, Unit 1 I PWR-DRYAMB 3,459 09/25/1968 86PSE&G Nuclear, LLC WEST 4LP DPR-70 12/01/1976 97 Hancocks Bridge, NJ PSEG 06/30/1977 88 (18 miles SE of Wilmington, DE)
UE&C 06/30/2011 86 05000272 08/13/2036 95https://www.nrc.gov/info-~nder/reactors/salm1.html 99 Salem Nuclear Generating Station, Unit 2 I PWR-DRYAMB 3,459 09/25/1968 89PSE&G Nuclear, LLC WEST 4LP DPR-75 05/20/1981 88 Hancocks Bridge, NJ PSEG 10/13/1981 100 (18 miles SE of Wilmington, DE)
UE&C 06/30/2011 73 05000311 04/18/2040 85https://www.nrc.gov/info-~nder/reactors/salm2.html 71Seabrook Station, Unit 1 I PWR-DRYAMB 3,648 07/07/1976 77NextEra Energy Seabrook, LLC WEST 4LP NPF-86 03/15/1990 75Seabrook, NH UE&C 08/19/1990 100 (13 miles S of Portsmouth, NH)
UE&C N/A 93 05000443 03/15/2030 87https://www.nrc.gov/info-~nder/reactors/seab1.html 90 Sequoyah Nuclear Plant, Unit 1 II PWR-ICECND 3,455 05/27/1970 98Tennessee Valley Authority WEST 4LP DPR-77 09/17/1980 89Soddy-Daisy, TN TVA 07/01/1981 83 (16 miles NE of Chattanooga, TN)
TVA N/A 100 05000327 09/17/2020 87https://www.nrc.gov/info-~nder/reactors/seq1.html 90 Sequoyah Nuclear Plant, Unit 2 II PWR-ICECND 3,455 05/27/1970 89Tennessee Valley Authority WEST 4LP DPR-79 09/15/1981 77Soddy-Daisy, TN TVA 06/01/1982 90 (16 miles NE of Chattanooga, TN)
TVA N/A 90 05000328 09/15/2021 73https://www.nrc.gov/info-~nder/reactors/seq2.html 95Shearon Harris Nuclear Power Plant, Unit 1 II PWR-DRYAMB 2,900 01/27/1978 103Duke Energy Progress, Inc. WEST 3LP NPF-63 10/24/1986 90 New Hill, NC EBSO 05/02/1987 83 (20 miles SW of Raleigh, NC) DANI 12/17/2008 99 05000400 10/24/2046 87https://www.nrc.gov/info-~nder/reactors/har1.html 88 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 104South Texas Project, Unit 1 IV PWR-DRYAMB 3,853 12/22/1975 94 STP Nuclear Operating Co. WEST 4LP NPF-76 03/22/1988 93Bay City, TX BECH 08/25/1988 91 (90 miles SW of Houston, TX) EBSO 09/28/2017 81 05000498 08/20/2047 78https://www.nrc.gov/info-~nder/reactors/stp1.html 73South Texas Project, Unit 2 IV PWR-DRYAMB 3,853 12/22/1975 88 STP Nuclear Operating Co. WEST 4LP NPF-80 03/28/1989 72Bay City, TX BECH 06/19/1989 59 (90 miles SW of Houston, TX) EBSO 09/28/2017 103 05000499 12/15/2048 85https://www.nrc.gov/info-~nder/reactors/stp2.html 92 Surry Power Station, Unit 1 II PWR-DRYSUB 2,587 06/25/1968 101Virginia Electric and Power Co.
WEST 3LP DPR-32 05/25/1972 92Surry, VA S&W 12/22/1972 91(17 miles NW of Newport News, VA) S&W 03/20/2003 99 05000280 05/25/2032 76https://www.nrc.gov/info-~nder/reactors/sur1.html 96 Surry Power Station, Unit 2 II PWR-DRYSUB 2,587 06/25/1968 76Virginia Electric and Power Co.
WEST 3LP DPR-37 01/29/1973 91Surry, VA S&W 05/01/1973 101(17 miles NW of Newport News, VA) S&W 03/20/2003 95 05000281 01/29/2033 82https://www.nrc.gov/info-~nder/reactors/sur2.html 101 Susquehanna Steam Electric Station, Unit 1 I BWR-MARK 2 3,952 11/03/1973 86Susquehanna Nuclear, LLC GE 4 NPF-14 07/17/1982 70Berwick, PA BECH 06/08/1983 87(70 miles NE of Harrisburg, PA) BECH 11/24/2009 83 05000387 07/17/2042 76https://www.nrc.gov/info-~nder/reactors/susq1.html 77 Susquehanna Steam Electric Station, Unit 2 I BWR-MARK 2 3,952 11/03/1973 72 PPL Susquehanna, LLC GE 4 NPF-22 03/23/1984 83Berwick, PA BECH 02/12/1985 80(70 miles NE of Harrisburg, PA) BECH 11/24/2009 88 05000388 03/23/2044 82https://www.nrc.gov/info-~nder/reactors/susq2.html 93Three Mile Island Nuclear Station, Unit 1 I PWR-DRYAMB 2,568 05/18/1968 92 Exelon Generation Co., LLC B&W LLP DPR-50 04/19/1974 100Middletown, PA GIL 09/02/1974 78(10 miles SE of Harrisburg, PA) UE&C 10/22/2009 104 05000289 04/19/2034 77https://www.nrc.gov/info-~nder/reactors/tmi1.html 82 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 105Turkey Point Nuclear Generating, Unit 3 II PWR-DRYAMB 2,644 04/27/1967 96 Florida Power & Light Co. WEST 3LP DPR-31 07/19/1972 40 Homestead, FL BECH 12/14/1972 81 (20 miles S of Miami, FL) BECH 06/06/2002 84 05000250 07/19/2032 78https://www.nrc.gov/info-~nder/reactors/tp3.html 93Turkey Point Nuclear Generating, Unit 4 II PWR-DRYAMB 2,644 04/27/1967 84 Florida Power & Light Co. WEST 3LP DPR-41 04/10/1973 85 Homestead, FL BECH 09/07/1973 70 (20 miles S of Miami, FL) BECH 06/06/2002 88 05000251 04/10/2033 106https://www.nrc.gov/info-~nder/reactors/tp4.html 99Virgil C. Summer Nuclear Station, Unit 1 II PWR-DRYAMB 2,900 03/21/1973 88South Carolina Electric & Gas Co.
WEST 3LP NPF-12 11/12/1982 86 Jenkinsville, SC GIL 01/01/1984 93 (26 miles NW of Columbia, SC)
DANI 04/23/2004 81 05000395 08/06/2042 79https://www.nrc.gov/info-~nder/reactors/sum.html 96Vogtle Electric Generating Plant, Unit 1 II PWR-DRYAMB 3,625.6 06/28/1974 92Southern Nuclear Operating Co., Inc. WEST 4LP NPF-68 03/16/1987 91Waynesboro, GA SBEC 06/01/1987 101 (26 miles SE of Augusta, GA) GPC 06/03/2009 87 05000424 01/16/2047 91https://www.nrc.gov/info-~nder/reactors/vog1.html 101Vogtle Electric Generating Plant, Unit 2 II PWR-DRYAMB 3,625.6 06/28/1974 94Southern Nuclear Operating Co., Inc. WEST 4LP NPF-81 03/31/1989 102Waynesboro, GA SBEC 05/20/1989 87 (26 miles SE of Augusta, GA) GPC 06/03/2009 92 05000425 02/09/2049 100https://www.nrc.gov/info-~nder/reactors/vog2.html 94Waterford Steam Electric Station, Unit 3 IV PWR-DRYAMB 3,716 11/14/1974 82Entergy Operations, Inc. COMB CE NPF-38 03/16/1985 77 Killona, LA EBSO 09/24/1985 89 (25 miles W of New Orleans, LA)
EBSO N/A 90 05000382 12/18/2024 80https://www.nrc.gov/info-~nder/reactors/wat3.html 96Watts Bar Nuclear Plant, Unit 1 II PWR-ICECND 3,459 01/23/1973 84Tennessee Valley Authority WEST 4LP NPF-90 02/07/1996 87Spring City, TN TVA 05/27/1996 90 (60 miles SW of Knoxville, TN) TVA N/A 89 05000390 11/09/2035 76https://www.nrc.gov/info-~nder/reactors/wb1.html 85 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 106Watts Bar Nuclear Plant, Unit 2 II PWR-ICECND 3,411 01/24/1973
---Tennessee Valley Authority WEST 4LP NPF-96 10/22/2015
---Spring City, TN TVA 10/19/2016
---(60 miles SW of Knoxville, TN) TVA N/A ---05000391 10/22/2055 0https://www.nrc.gov/info-~nder/reactors/wb2.html 26Wolf Creek Generating Station, Unit 1 IV PWR-DRYAMB 3,565 05/17/1977 72Wolf Creek Nuclear Operating Corp. WEST 4LP NPF-42 06/04/1985 H 80Burlington (Coffey County), KS BECH 09/03/1985 65 (28 miles SE of Emporia, KS) DANI 11/20/2008 83 05000482 03/11/2045 78https://www.nrc.gov/info-~nder/reactors/wc.html 74 H: The original OL (NPF-32) was issued on 03/11/1985. The license was superseded by OL (NPF-42), issued on 06/04/1985.
Bellefonte Nuclear Power Station, Unit 1**
II PWR-DRYAMB 3,763 12/24/1974 N/ATennessee Valley Authority B&W 205 (6 miles NE of Scottsboro, AL) TVA 05000438 TVAhttp://www.nrc.gov/reactors/new-reactors/col/bellefonte.html Bellefonte Nuclear Power Station, Unit 2**
II PWR-DRYAMB 3,763 12/24/1974 N/ATennessee Valley Authority B&W 205 (6 miles NE of Scottsboro, AL) TVA 05000439 TVAhttp://www.nrc.gov/reactors/new-reactors/col/bellefonte.html Enrico Fermi Nuclear Plant, Unit 3 III ESBWR 4,500 N/A DTE Electric Company GEH NPF-95 05/01/2015 Newport, MI (25 miles NE of Toledo, OH) 05200033 https://www.nrc.gov/reactors/new-reactors/col-holder/ferm3.html
Levy County Nuclear Plant, Unit 1 A III PWR 3,400 N/ADuke Energy Florida, LLC AP1000 NPF-99 10/26/2016Levy County, FL WEST 2LP (2 miles NE of Inglis, FL) 05200029 https://www.nrc.gov/reactors/new-reactors/col-holder/levy1.html APPENDIX ACommercial Nuclear Power Reactors Operating Reactors (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent)Operating Reactors Under Active Construction or Deferred Policy Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent) 107 APPENDIX ACommercial Nuclear Power Reactors Operating Reactors under Active Construction or Deferred Policy (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type Licensed OL Issued 2016*Location NSSS MWt Comm. Op. CapacityDocket Number NRC Architect Engineer License LR Issued FactorNRC Web Page Address Region Constructor Number Exp. Date (Percent)Levy County Nuclear Plant, Unit 2 A III PWR 3,400 N/ADuke Energy FL, LLC AP1000 NPF-100 10/26/2016Levy County, FL WEST 2LP (2 miles NE of Inglis, FL) 05200030 https://www.nrc.gov/reactors/new-reactors/col-holder/levy2.html North Anna Power Station, Unit 3 II BWR 4,500 N/ADominion Virginia Power ESBWR NPF-103 06/02/2017 Mineral (Louisa County), VA GEH (40 miles NW of Richmond, VA) 05200017 https://www.nrc.gov/reactors/new-reactors/col-holder/na3.html South Texas Project, Unit 3 IV BWR 3,926 N/A STP Nuclear Operating Co. ABWR NPF-97 02/12/2016 Bay City, TX (90 miles SW of Houston, TX) 05200012 https://www.nrc.gov/reactors/new-reactors/col-holder/stp3.html South Texas Project, Unit 4 IV BWR 3,926 N/A STP Nuclear Operating Co. ABWR NPF-98 02/12/2016 Bay City, TX (90 miles SW of Houston, TX) 05200013 https://www.nrc.gov/reactors/new-reactors/col-holder/stp4.html Virgil C. Summer Nuclear Station, Unit 2 B II PWR 3,400 N/ASouth Carolina Electric & Gas Co.
AP1000 NPF-93 03/30/2012South Carolina Public Service Auth. WEST 2LP Jenkinsville (Fair~eld County), SC (26 miles NW of Columbia, SC) 0520027 https://www.nrc.gov/reactors/new-reactors/col-holder/sum2.htmlVirgil C. Summer Nuclear Station, Unit 3 B II PWR 3,400 N/ASouth Carolina Electric & Gas Co.
AP1000 NPF-94 03/30/2012South Carolina Public Service Auth. WEST 2LP Jenkinsville (Fair~eld County), SC (26 miles NW of Columbia, SC) 05200028 https://www.nrc.gov/reactors/new-reactors/col-holder/sum3.html A: In September 2017, Duke Energy Florida announced cancellation of Levy County nuclear power plant, Units 1 and 2 project. B: On July 31, 2017, South Carolina Electric & Gas (SCE&G) to ceased construction on V.C. Summer nuclear power plant, Units 2 and 3.
108Vogtle Electric Generating Plant, Unit 3 II PWR 3,400 N/ASouthern Nuclear Operating Co., Inc. AP1000 NPF-91 02/10/2012Waynesboro (Burke County), GA WEST 2LP (26 miles SE of Augusta, GA) 05200025 https://www.nrc.gov/reactors/new-reactors/col-holder/vog3.htmlVogtle Electric Generating Plant, Unit 4 II PWR 3,400 N/ASouthern Nuclear Operating Co., Inc. AP1000 NPF-92 02/10/2012Waynesboro, (Burke County), GA WEST 2LP (26 miles SE of Augusta, GA) 05200026 https://www.nrc.gov/reactors/new-reactors/col-holder/vog4.html
William States Lee III Nuclear Station, Unit 3 C II PWR 3,400 N/ADuke Energy Carolinas AP1000 NPF-101 12/19/2016Cherokee County, SC WEST 2LP(2 miles SE of Gafney, SC) 05200018 https://www.nrc.gov/reactors/new-reactors/col-holder/lee1.html William States Lee III Nuclear Station, Unit 4 C II PWR 3,400 N/ADuke Energy Carolinas AP1000 NPF-102 12/19/2016Cherokee County, SC WEST 2LP(2 miles SE of Gafney, SC) 05200019 https://www.nrc.gov/reactors/new-reactors/col-holder/lee2.html APPENDIX ACommercial Nuclear Power Reactors Operating Reactors under Active Construction or Deferred Policy (continued)
Plant Name, Unit Number CP Issued 2011-Licensee Con Type COL Issued 2016*Location NSSS Comm. Op. CapacityDocket Number NRC Architect Engineer Licensed LR Issued FactorNRC Web Page Address Region Constructor MWt Exp. Date (Percent)C: In September 2017, Duke Energy announced cancellation of the William States Lee nuclear power plant, Units 3 and 4 project.
- Average capacity factor is listed in year order starting with 2009. ** Bellefonte Units 1 and 2 are under the Commission Policy Statement on Deferred Plants (52 FR 38077; October 14, 1987).Note: Plant names and data are as identi~ed on the license as of July 2017; the next printed update will be in August 2018.
Source: NRC, with some data compiled from U.S. Department of Energy's (DOE's) Energy Information Administration (EIA).
109 Applicant Docket Number TypeSubmittal
Date Design Site StateExisting Plant?Date Accepted Status Combined Operating LicenseNuclear Innovation North America, LLC 05200012 &
05200013 COL 9/20/07 ABWRSouth Texas Project, Units 3 and 4 TXYes 11/29/07 COL Issued 02/09/2016Tennessee Valley Authority (TVA)05200014 &
05200015 COL 10/30/07 AP1000Bellefonte, Units 3 and 4 AL No 1/18/08Withdrawn-
12/02/2016Dominion Virginia Power 05200017 COL 11/27/07 ESBWRNorth Anna, Unit 3 VAYes 01/28/08 COL Issued 06/02/2017 Duke Energy Carolinas05200018 &
05200019 COL 12/13/07 AP1000Lee Nuclear Station, Units 3 and 4 SC No 2/25/08 COL Issued 12/19/2016 Progressive Energy05200022 &
05200023 COL 2/19/08 AP1000Shearon Harris, Units 2 and 3 NCYes 4/17/08 Suspended-
05/02/2013Southern Nuclear Operating Co.05200025 &
05200026 COL 3/31/08 AP1000Vogtle, Units 3 and 4 GAYes 5/30/08 COL Issued
02/10/2012South Carolina Electric and Gas05200027 &
05200028 COL 3/31/08 AP1000V.C. Summer, Units 2 and 3 SCYes 7/31/08 COL Issued
03/30/2012 AmerenUE 05200037 COL 7/24/08U.S. EPRCallaway, Unit 2 MOYes 12/12/08Withdrawn-
10/19/2015Duke Energy Florida05200029 &
05200030 COL 7/30/08 AP1000Levy County, Units 1 and 2 FL No 10/6/08 COL Issued
10/26/2016DTE Electric Company 05200033 COL 9/18/08 ESBWRFermi, Unit 3 MIYes 11/25/08 COL Issued 05/01/2015Luminant Generation Co.05200034 &
05200035 COL 9/19/08 US-APWRComanche Peak, Units 3 and 4 TXYes 12/2/08 Suspended-
03/31/2014Entergy 05200036 COL 9/25/08 ESBWRRiver Bend, Unit 3 LAYes 12/4/08Withdrawn-
06/14/2016 PPL Bell Bend 05200039 COL 10/10/08U.S. EPRBell Bend (1 Unit)PAYes 12/19/08Withdrawn-
09/22/2016Florida Power and Light05200040 &
05200041 COL 6/30/09 AP1000Turkey Point, Units 6 and 7 FLYes 9/4/09 Scheduled Design Certi~cationAREVA NP 05200020 DC 12/11/07U.S. EPR N/A N/A N/A 2/25/08Suspended-
03/27/2015Mitsubishi Heavy
Industries 05200021 DC 12/31/07 US-APWR N/A N/A N/A 2/29/08Applicant Delayed
-Not ScheduledKorea Electric Power Company and Korea Hydro and Nuclear Power 05200046 DC 12/23/14 APR 1400 N/A N/A N/A 3/4/15Scheduled Toshiba Corporation 05200044 DC 10/27/10 ABWR N/A N/A N/A 12/14/10Withdrawn-
12/30/2016GE-Hitachi Nuclear Energy 05200045DC 12/7/10 ABWR N/A N/A N/A 2/14/11 ScheduledNuScale Power LLC 05200048DC 01/06/17 NuScale N/A N/A N/A 3/23/17 Scheduled Early Site Permit PSEG Site 05200043 ESP 5/25/10Not yet announced PSEG Site NJYes 8/4/10Issued 05/06/2016TVA Clinch River SMR Site 05200043 ESP 5/25/10Not yet announced Clinch River Site TN No 1/12/17 Scheduled APPENDIX B New Nuclear Power Plant Licensing Applications Notes: Withdrawal was requested for Calvert Cliffs, Grand Gulf, Nine Mile Point, Victoria County, and Callaway (COL and ESP). On July 31, 2017, a decision was announced by South Carolina Electric & Gas (SCE&G) to cease construction on V.C. Summer nuclear power plant, Units 2 and 3.
In September 2017, Duke Energy has announced cancellation of the William States Lee nuclear power plant, Units 3 and 4 project, and Levy County Units 1 and 2. Data are current as of October 2017; the next printed update will be in August 2018. NRC-abbreviated reactor names listed.
110 APPENDIX CCommercial Nuclear Power Reactors Undergoing Decommissioning and Permanently Shut Down Formerly Licensed To Operate Unit Reactor NSSS OL Issued Decommissioning Location Type Vendor Shut Down Alternative Selected Docket Number MWt OL Terminated Current License Status Closure Date Est.
Big Rock Point BWR GE 05/01/1964 DECON Charlevoix, MI 240 08/29/1997 DECON Completed 05000155 01/08/2007 Crystal River 3 PWR B&W LLP 12/03/1976 SAFSTOR Crystal River, FL 2,609 02/20/2013 SAFSTOR in Progress 05000302 2074Dresden 1 BWR GE 09/28/1959 SAFSTOR Morris, IL 700 10/31/1978 SAFSTOR 05000010 2036 GE EVESR Experimental GE 11/12/1963 SAFSTOR Sunol, CA Superheat Reactor 02/1/1967 Possession Only 05000183 12.5 04/15/1970 License Expires 01/1/2019 01/2016GE VBWR (Vallecitos)
BWR GE 08/31/1957 SAFSTOR Sunol, CA 50 12/09/1963 SAFSTOR 05000018 2019 Fermi 1 SCF CE 05/10/1963 SAFSTOR Newport, MI 200 09/22/1972 DECON 05000016 2032 Fort Calhoun 1 PWR-DRYAMB CE 08/09/1973 SAFSTOR Ft. Calhoun, NE 1,500 10/24/2016 SAFSTOR in Progress 05000285 2065 Fort St. Vrain HTG GA 12/21/1973 DECON Platteville, CO 842 08/18/1989 DECON Completed 05000267 08/08/1997 Haddam Neck PWR WEST 12/27/1974 DECON Meriden, CT 1,825 12/05/1996 DECON Completed 05000213 11/26/2007
111 APPENDIX CCommercial Nuclear Power Reactors Undergoing Decommissioning and Permanently Shut Down Formerly Licensed To Operate (continued)
Unit Reactor NSSS OL Issued Decommissioning Location Type Vendor Shut Down Alternative Selected Docket Number MWt OL Terminated Current License Status Closure Date Est.
Humboldt Bay 3 BWR GE 08/28/1962 DECON Eureka, CA 200 07/02/1976 DECON in Progress 05000133 2017 Indian Point 1 PWR B&W 03/26/1962 SAFSTOR Buchanan, NY 615 10/31/1974 SAFSTOR 05000003 2026 Kewaunee PWR WEST 2LP 12/21/1973 SAFSTOR Carlton, WI 1,772 05/07/2013 SAFSTOR 05000305 2073La Crosse BWR AC 07/03/1967 DECON Genoa, WI 165 04/30/1987 DECON in Progress 05000409 TBD Maine Yankee PWR CE 06/29/1973 DECON Wiscasset, ME 2,700 12/06/1996 DECON Completed 05000309 09/30/2005 Millstone 1 BWR GE 10/31/1970 SAFSTOR Waterford, CT 2,011 07/21/1998 SAFSTOR 05000245 12/31/2056
Path~nder BWR AC 03/12/1964 DECON Sioux Falls, SD 190 09/16/1967 DECON Completed 05000130 07/27/2007 Peach Bottom 1 HTG GA 01/24/1966 SAFSTOR Delta, PA 115 10/31/1974 SAFSTOR 05000171 12/31/2034 Rancho Seco PWR B&W 08/16/1974 DECON Herald, CA 2,772 06/07/1989 DECON Completed 05000312 09/25/2009
San Onofre 1*
PWR WEST 03/27/1967 DECON San Clemente, CA 1,347 11/30/1992 SAFSTOR 05000206 12/30/2030
112 APPENDIX CCommercial Nuclear Power Reactors Undergoing Decommissioning and Permanently Shut Down Formerly Licensed To Operate (continued)
Unit Reactor NSSS OL Issued Decommissioning Location Type Vendor Shut Down Alternative Selected Docket Number MWt OL Terminated Current License Status Closure Date Est.San Onofre 2*
PWR CE CE 02/16/1982 DECON San Clemente, CA 3,438 06/12/2013 DECON in Progress 05000361 2030San Onofre 3 PWR CE CE 11/15/1982 DECON San Clemente, CA 3,438 06/12/2013 DECON in Progress 05000362 2030 Savannah, N.S.
PWR B&W 08/1965 SAFSTOR Baltimore, MD 74 11/1970 SAFSTOR 05000238 12/01/2031 Saxton PWR WEST 11/15/1961 DECON Saxton, PA 23.5 05/01/1972 DECON Completed 05000146 11/07/2005 Shoreham BWR GE 04/21/1989 DECON Wading River, NY 2,436 06/28/1989 DECON Completed 05000322 04/11/1995
Three Mile Island 2 PWR B&W 02/08/1978
Vermont Yankee BWR-Mark 1 GE 4 03/21/1972 SAFSTOR Vernon, VT 1,912 12/29/2014 SAFSTOR in Progress 05000271 2073 Zion 1 PWR WEST 10/19/1973 DECON Zion, IL 3,250 02/21/1997 DECON in Progress 05000295 113 APPENDIX CCommercial Nuclear Power Reactors Undergoing Decommissioning and Permanently Shut Down Formerly Licensed To Operate (continued)
Unit Reactor NSSS OL Issued Decommissioning Location Type Vendor Shut Down Alternative Selected Docket Number MWt OL Terminated Current License Status Closure Date Est.
Zion 2 PWR WEST 11/14/1973 DECON Zion, IL 3,250 09/19/1996 DECON in Progress 05000304 2020
- Site has been dismantled and decontaminated with the exception of the reactor vessel, which is in long-term storage.
- Three Mile Island Unit 2 has been placed in a postdefueling monitored storage mode until Unit 1 permanently ceases operation, at which time both units are planned to be decommissioned.Notes: GE Bonus, Hallam, and Piqua decommissioned reactor sites are part of the DOE nuclear legacy. For more information, visit DOE's Legacy Management Web site at http://energy.gov/lm/sites/lm-sites. CVTR, Elk River, and Shippingport decommissioned reactor sites were either decommissioned prior to the formation of the NRC or were not licensed by the NRC.
See the Glossary for de~nitions of decommissioning alternatives (DECON, SAFSTOR).
Source: DOE, "Integrated Database for 1990, U.S. Spent Fuel and Radioactive Waste, Inventories, Projections, and Characteristics" (DOE/RW-0006, Rev. 6), and NRC, "Nuclear Power Plants in the World," Edition 6.Data are current as of July 2017. The next printed update will be in August 2018.
114 APPENDIX DCanceled Commercial Nuclear Power ReactorsPart 50-Domestic Licensing of Production and Utilization Facilities Unit Canceled Date Utility Con Type Status Location MWe per Unit Docket NumberAllens Creek 1 BWR 1982 Houston Lighting & Power Company 1,150 Under CP Review 4 miles NW of Wallis, TX 05000466Allens Creek 2 BWR 1976 Houston Lighting & Power Company 1,150 Under CP Review 4 miles NW of Wallis, TX 05000467 Atlantic 1 & 2 PWR 1978 Public Service Electric & Gas Company 1,150 Under CP Review Floating plants off the coast of NJ 05000477 & 478 Bailly 1 BWR 1981 Northern Indiana Public Service Company 645 With CP 12 miles NNE of Gary, IN 05000367 Barton 1 & 2 BWR 1977 Alabama Power & Light 1,159 Under CP Review 15 miles SE of Clanton, AL 05000524 & 525 Barton 3 & 4 BWR 1975 Alabama Power & Light 1,159 Under CP Review 15 miles SE of Clanton, AL 05000526 & 527 Black Fox 1 & 2 BWR 1982 Public Service Company of Oklahoma 1,150 Under CP Review
3.5 miles
S of Inola, OK 05000556 & 557 Blue Hills 1 & 2 PWR 1978 Gulf States Utilities Company 918 Under CP Review SW tip of Toledo Bend Reservoir, TX 05000510 & 511Cherokee 1 PWR 1983 Duke Power Company 1,280 With CP 6 miles SSW of Blacksburg, SC 05000491Cherokee 2 & 3 PWR 1982 Duke Power Company 1,280 With CP 6 miles SSW of Blacksburg, SC 05000492 & 493 Clinch River LMFB 1983 Project Management Corp., DOE, TVA 350 Under CP Review 23 miles W of Knoxville, in Oak Ridge, TN 05000537 Clinton 2 BWR 1983 Illinois Power Company 933 With CP 6 miles E of Clinton, IL 05000462 Davis-Besse 2 & 3 PWR 1981 Toledo Edison Company 906 Under CP Review 21 miles ESE of Toledo, OH 05000500 & 501 115 APPENDIX DCanceled Commercial Nuclear Power Reactors (continued)Part 50-Domestic Licensing of Production and Utilization Facilities Unit Canceled Date Utility Con Type Status Location MWe per Unit Docket Number Douglas Point 1 & 2 BWR 1977 Potomac Electric Power Company 1,146 Under CP Review Charles County, MD 05000448 & 449 Erie 1 & 2 PWR 1980 Ohio Edison Company 1,260 Under CP Review Berlin, OH 05000580 & 581 Forked River 1 PWR 1980 Jersey Central Power & Light Company 1,070 With CP 2 miles S of Forked River, NJ 05000363 Fort Calhoun 2 PWR 1977 Omaha Public Power District 1,136 Under CP Review 19 miles N of Omaha, NE 05000548 Fulton 1 & 2 HTG 1975 Philadelphia Electric Company 1,160 Under CP Review 17 miles S of Lancaster, PA 05000463 & 464 Grand Gulf 2 BWR 1990 Entergy Nuclear Operations, Inc.
1,250 With CP 20 miles SW of Vicksburg, MS 05000417Greene County PWR 1980 Power Authority of the State of NY 1,191 Under CP Review 20 miles N of Kingston, NY 05000549Greenwood 2 & 3 PWR 1980 Detroit Edison Company 1,200 Under CP Review Greenwood Township, MI 05000452 & 453 Hartsville A1 & A2 BWR 1984 Tennessee Valley Authority 1,233 With CP 5 miles SE of Hartsville, TN 05000518 & 519 Hartsville B1 & B2 BWR 1982 Tennessee Valley Authority 1,233 With CP 5 miles SE of Hartsville, TN 05000520 & 521 Haven 1 (formerly Koshkonong)
PWR 1980 Wisconsin Electric Power Company 900 Under CP Review
4.2 miles
SSW of Fort Atkinson, WI 05000502 Haven 2 (formerly Koshkonong)
PWR 1978 Wisconsin Electric Power Company 900 Under CP Review
4.2 miles
SSW of Fort Atkinson, WI 05000503Hope Creek 2 BWR 1981 Public Service Electric & Gas Company 1,067 With CP 18 miles SE of Wilmington, DE 05000355 116 APPENDIX DCanceled Commercial Nuclear Power Reactors (continued)Part 50-Domestic Licensing of Production and Utilization Facilities Unit Canceled Date Utility Con Type Status Location MWe per Unit Docket Number Jamesport 1 & 2 PWR 1980 Long Island Lighting Company 1,150 With CP 65 miles E of New York City, NY 05000516 & 517 Marble Hill 1 & 2 PWR 1985 Public Service of Indiana 1,130 With CP 6 miles NE of New Washington, IN 05000546 & 547 Midland 1 PWR 1986 Consumers Power Company 492 With CP S of City of Midland, MI 05000329 Midland 2 PWR 1986 Consumers Power Company 818 With CP S of City of Midland, MI 05000330 Montague 1 & 2 BWR 1980 Northeast Nuclear Energy Company 1,150 Under CP Review
1.2 miles
SSE of Turners Falls, MA 05000496 & 497 New England 1 & 2 PWR 1979 New England Power Company 1,194 Under CP Review
8.5 miles
E of Westerly, RI 05000568 & 569 New Haven 1 & 2 PWR 1980 New York State Electric & Gas Corporation 1,250 Under CP Review 3 miles NW of New Haven, NY 05000596 & 597 North Anna 3 PWR 1982 Virginia Electric & Power Company 907 With CP 40 miles NW of Richmond, VA 05000404 North Anna 4 PWR 1980 Virginia Electric & Power Company 907 With CP 40 miles NW of Richmond, VA 05000405 North Coast 1 PWR 1978 Puerto Rico Water Resources Authority 583 Under CP Review
4.7 miles
ESE of Salinas, PR 05000376Palo Verde 4 & 5 PWR 1979 Arizona Public Service Company 1,270 Under CP Review 36 miles W of Phoenix, AZ 05000592 & 593 Pebble Springs 1 & 2 PWR 1982 Portland General Electric Company 1,260 Under CP Review 55 miles WSW of Richland, WA, near Arlington, OR 05000514 & 515 Perkins 1, 2, & 3 PWR 1982 Duke Power Company 1,280 Under CP Review 10 miles N of Salisbury, NC 05000488, 489 & 490 117 APPENDIX DCanceled Commercial Nuclear Power Reactors (continued)Part 50-Domestic Licensing of Production and Utilization Facilities Unit Canceled Date Utility Con Type Status Location MWe per Unit Docket Number Perry 2 BWR 1994 Cleveland Electric Illuminating Co.
1,205 Under CP Review 35 miles NE of Cleveland, OH 05000441 Phipps Bend 1 & 2 BWR 1982 Tennessee Valley Authority 1,220 With CP 15 miles SW of Kingsport, TN 05000553 & 554 Pilgrim 2 PWR 1981 Boston Edison Company 1,180 Under CP Review 4 miles SE of Plymouth, MA 05000471 Pilgrim 3 PWR 1974 Boston Edison Company 1,180 Under CP Review 4 miles SE of Plymouth, MA 05000472 Quanicassee 1 & 2 PWR 1974 Consumers Power Company 1,150 Under CP Review 6 miles E of Essexville, MI 05000475 & 476 River Bend 2 BWR 1984 Gulf States Utilities Company 934 With CP 24 miles NNW of Baton Rouge, LA 05000459Seabrook 2 PWR 1988 Public Service Co. of New Hampshire 1,198 With CP 13 miles S of Portsmouth, NH 05000444Shearon Harris 2 PWR 1983 Carolina Power & Light Company 900 With CP 20 miles SW of Raleigh, NC 05000401Shearon Harris 3 & 4 PWR 1981 Carolina Power & Light Company 900 With CP 20 miles SW of Raleigh, NC 05000402 & 403Skagit/Hanford 1 & 2 PWR 1983 Puget Sound Power & Light Company 1,277 Under CP Review 23 miles SE of Bellingham, WA 05000522 & 523 Sterling PWR 1980 Rochester Gas & Electric Corporation 1,150 With CP 50 miles E of Rochester, NY 05000485 Summit 1 & 2 HTG 1975 Delmarva Power & Light Company 1,200 Under CP Review 15 miles SSW of Wilmington, DE 05000450 & 451 Sundesert 1 & 2 PWR 1978 San Diego Gas & Electric Company 974 Under CP Review 16 miles SW of Blythe, CA 05000582 & 583 118 APPENDIX DCanceled Commercial Nuclear Power Reactors (continued)Part 50-Domestic Licensing of Production and Utilization Facilities Unit Canceled Date Utility Con Type Status Location MWe per Unit Docket Number Surry 3 & 4 PWR 1977 Virginia Electric & Power Company 882 With CP 17 miles NW of Newport News, VA 05000434 & 435Tyrone 1 PWR 1981 Northern States Power Company 1,150 Under CP Review 8 miles NE of Durond, WI 05000484Tyrone 2 PWR 1974 Northern States Power Company 1,150 With CP 8 miles NE of Durond, WI 05000487Vogtle 3 & 4 PWR 1974 Georgia Power Company 1,113 With CP 26 miles SE of Augusta, GA 050000426 & 427Washington Nuclear 1 (WPPSS)
PWR 1995 Energy Northwest 1,266 With CP 12 miles NE of Richland, WA 05000460Washington Nuclear 3 (WPPSS)
PWR 1995 Energy Northwest 1,242 With CP 12 miles NE of Richland, WA 05000508Washington Nuclear 4 (WPPSS)
PWR 1982 Energy Northwest 1,218 With CP 12 miles NE of Richland, WA 05000513Washington Nuclear 5 (WPPSS)
PWR 1982 Energy Northwest 1,242 With CP 12 miles NE of Richland, WA 05000509Yellow Creek 1 & 2 BWR 1984 Tennessee Valley Authority 1,285 With CP 15 miles E of Corinth, MS 05000566 & 567 Zimmer 1 BWR 1984 Cincinnati Gas & Electric Company 810 With CP 25 miles SE of Cincinnati, OH 05000358 Bellefonte 3 & 4 AP1000 2016 Tennessee Valley Authority 1,100 With COL Scottsboro, Jackson County, AL 05200014 & 05200015 Bell Bend U.S. EPR 2016 Bell Bend, LLC 1,600 With COL Luzerne County, PA 5200039 119 Callaway 2 U.S. EPR 2015 Union Electric Company (Ameren UE) 1,600 With COL Fulton, Callaway County , MO 05200037Calvert Cliffs 3 U.S. EPR July 17, 2015 UniStar Nuclear Operating Services, LLC 4,500 With COL Review Near Lusby in Calvert County, MD 05200016 Grand Gulf 3 ESBWR January 9, 2009 Entergy Operations, Inc.
4,500 With COL Review Near Port Gibson in Claiborne County, MS 05200024 Nine Mile Point 3 ESBWR January 9, 2009 UniStar Nuclear Operating Services, LLC 4,500 With COL Review 25 miles SE of Cincinnati, OH 0500038 River Bend 3 ESBWR 2016 Entergy Operations, Inc.
1,594 With COL St. Francisville, LA 5200036 Victoria County Station 1 and 2 ESBWR June 11, 2010 Exelon Nuclear Texas Holdings, LLC 4,500 With COL Review Near Victoria City in Victoria County, TX 05200031 & 05200032 APPENDIX DCanceled Commercial Nuclear Power Reactors (continued)Part 52-Licensing, Certi~cation, and Approvals for Nuclear Power Plants Unit Canceled Date Utility Con Type Status Location MWe per Unit Docket Number Notes: Cancellation is de~ned as public announcement of cancellation or written noti~cation to the NRC. Only NRC-docketed applications are included. "Status" is the status of the application at the time of cancellation.Data are current as of July 2017; the next printed update will be in August 2018.
Withdrawal was requested for Calvert Cliffs, Grand Gulf, Nine Mile Point, Victoria County, and Callaway (COL and ESP). NRC-abbreviated reactor names listed.Source: DOE/EIA, "Commercial Nuclear Power 1991," DOE/EIA-0438, Appendix E, and the NRC.
120 APPENDIX ECommercial Nuclear Power Reactors by Parent Company Utility NRC-Abbreviated Reactor Unit NameAmerenUE Callaway* www.ameren.com Arizona Public Service Company Palo Verde 1, 2, & 3*
www.aps.com Dominion Generation Millstone 2 & 3 www.dom.com North Anna 1 & 2 Surry 1 & 2 DTE Electric Company Fermi 2 www.dteenergy.com Duke Energy Brunswick 1 & 2 www.duke-energy.com Catawba 1 & 2 Harris 1 McGuire 1 & 2 Oconee 1, 2, & 3 Robinson 2Energy Northwest Columbia www.energy-northwest.comEntergy Nuclear Operations, Inc.
Arkansas Nuclear One 1 & 2 www.entergy-nuclear.com FitzPatrick Grand Gulf 1 Indian Point 2 & 3 Palisades Pilgrim 1 River Bend 1 Waterford 3 Exelon Corporation, LLC Braidwood 1 & 2 www.exeloncorp.com Byron 1 & 2 Calvert Cliffs 1 & 2 Clinton Dresden 2 & 3 Ginna LaSalle 1 & 2 Limerick 1 & 2 Nine Mile Point 1 & 2 Oyster Creek Peach Bottom 2 & 3 Quad Cities 1 & 2 Three Mile Island 1First Energy Nuclear Operating Company Beaver Valley 1 & 2 www.~rstenergycorp.com Davis-Besse
Perry 1 121 APPENDIX ECommercial Nuclear Power Reactors by Parent Company (continued)
Utility NRC-Abbreviated Reactor Unit Name Indiana Michigan Power Company Cook 1 & 2 www.indianamichiganpower.com Nebraska Public Power District Cooper www.nppd.comNextEra Energy Inc. with principal subsidiaries Duane Arnold Florida Power & Light Co. and Point Beach 1 & 2 NextEra Energy Resources, LLC Seabrook 1 www.fplgroup.com St. Lucie 1 & 2 Turkey Point 3 & 4Northern States Power Company Monticello Minnesota doing business as Xcel Energy Prairie Island 1 & 2 www.xcelenergy.com
Paci~c Gas & Electric Company Diablo Canyon 1 & 2*
www.pge.comPSEG Nuclear, LLC Hope Creek 1 www.pseg.com Salem 1 & 2South Carolina Electric & Gas Company Summer www.sceg.comSouthern Nuclear Operating Company Farley 1 & 2 www.southerncompany.com Hatch 1 & 2 Vogtle 1 & 2 STP Nuclear Operating Company South Texas Project 1 & 2*
www.stpegs.comTalen Energy Corp.
Susquehanna 1 & 2 www.talenenergy.comTennessee Valley Authority Browns Ferry 1, 2, & 3 www.tva.gov Sequoyah 1 & 2 Watts Bar 1 & 2Vistra Energy Comanche Peak 1 & 2*
www.vistraenergy.com Wolf Creek Nuclear Operating Corporation Wolf Creek 1*
www.wcnoc.com
- These plants have a joint program called the Strategic Teaming and Resource Sharing group.
They share resources for refueling outages and develop some shared licensing applications.Note: Data are current as of July 2017; the next printed update will be in August 2018.
122* AEC Issued a provisional operating license allowing commercial operations.Notes: This list is limited to reactors licensed to operate. Year is based on the date the initial full-power operating license was issued.
NRC-abbreviated reactor names are listed. Data are current as of July 2017; the next printed update will be in August 2018.
1969Dresden 2*
Ginna*Nine Mile Point 1*Oyster Creek*
1970 Point Beach 1*
Robinson 2 1971Dresden 3 Monticello*
1972 Palisades*
Pilgrim Quad Cities 1
Quad Cities 2 Surry 1Turkey Point 3 1973Browns Ferry 1 Indian Point 2 Oconee 1 Oconee 2 Peach Bottom 2
Point Beach 2*
Surry 2Turkey Point 4 1974 Arkansas Nuclear 1Browns Ferry 2 Brunswick 2Calvert Cliffs 1 Cooper Cook 1 Duane Arnold FitzPatrick
Hatch 1 Oconee 3 Peach Bottom 3 Prairie Island 1 Prairie Island 2Three Mile Island 1 1975 Millstone 2 1976Beaver Valley 1Browns Ferry 3 Brunswick 1 Calvert Cliffs 2 Indian Point 3 Salem 1 St. Lucie 1 1977 Davis-Besse D.C. Cook 2 Farley 1 1978 Arkansas Nuclear 2 Hatch 2 North Anna 1 1980 North Anna 2 Sequoyah 1 1981 Farley 2McGuire 1 Salem 2 Sequoyah 2 1982 LaSalle 1 SummerSusquehanna 1 1983McGuire 2 St. Lucie 2 1984 Callaway Columbia Diablo Canyon 1 Grand Gulf 1 LaSalle 2 Susquehanna 2 1985Byron 1 Catawba 1 Diablo Canyon 2 Fermi 2 Limerick 1 Palo Verde 1 River Bend 1Waterford 3Wolf Creek 1 1986 Catawba 2Hope Creek 1 Millstone 3 Palo Verde 2 Perry 1 1987Beaver Valley 2 Braidwood 1Byron 2 Clinton Harris 1 Nine Mile Point 2Palo Verde 3 Vogtle 1 1988 Braidwood 2South Texas Project 1 1989 Limerick 2 South Texas Project 2Vogtle 2 1990 Comanche Peak 1Seabrook 1 1993 Comanche Peak 2 1996Watts Bar 1 APPENDIX FCommercial Nuclear Power Reactor Operating Licenses-Issued by Year APPENDIX GCommercial Nuclear Power Reactor Operating Licenses-Expiration by Year, 2013-2055Notes: This list includes Indian Point 2 & 3, which entered timely renewal on September 29, 2013, and December 12, 2015. Limited to reactors licensed to operate. NRC-abbreviated reactor names listed. Data are current as of October 2017; the next printed update will be in August 2018.2013 Indian Point 2 2015 Indian Point 3 2024 Diablo Canyon 1Waterford 3 2025 Diablo Canyon 2 River Bend 1 2026 Clinton Perry 2029Ginna Nine Mile Point 1 Oyster Creek 2030 Comanche Peak 1
Monticello
Point Beach 1 Robinson 2Seabrook 2031Dresden 3 Palisades 2032Pilgrim Quad Cities 1
Quad Cities 2 Surry 1Turkey Point 3 2033Browns Ferry 1
Comanche Peak 2
Fort Calhoun Oconee 1 Oconee 2 Peach Bottom 2
Point Beach 2 Prairie Island 1 Surry 2 Turkey Point 4 2034 Arkansas Nuclear 1Browns Ferry 2 Brunswick 2 Calvert Cliffs 1 Cook 1 Cooper Duane Arnold
Hatch 1 FitzPatrick Oconee 3 Peach Bottom 3
Prairie Island 2Three Mile Island 1 2035Millstone 2 Watts Bar 1 2036Beaver Valley 1 Browns Ferry 3 Brunswick 1 Calvert Cliffs 2 St. Lucie 1
Salem 1 2037Cook 2 Davis-Besse 1 Farley 1 2038 Arkansas Nuclear 2 Hatch 2 North Anna 1 2040 North Anna 2
Salem 2 Sequoyah 1 2041 Farley 2McGuire 1 Sequoyah 2 2042 LaSalle 1 Summer Susquehanna 1 2043 Catawba 1 Catawba 2 Columbia LaSalle 2 McGuire 2 St. Lucie 2 2044Byron 1 Calloway Grand Gulf 1 Limerick 1 Susquehanna 2 2045 Fermi 2 Millstone 3 Palo Verde 1Wolf Creek 1 2046 Braidwood 1 Byron 2 Harris 1Hope CreekNine Mile Point 2 Palo Verde 2 2047Beaver Valley 2 Braidwood 2 Palo Verde 3South Texas Project 1 Vogtle 12048 South Texas Project 2 2049 Limerick 2 Vogtle 2 2055Watts Bar 2 123 APPENDIX HOperating Nuclear Research and Test Reactors Regulated by the NRC Licensee Reactor Type Power Level Licensee Number Location OL Issued (kW) Docket NumberAerotest TRIGA (Indus) 250 R-98 San Ramon, CA 07/02/1965 05000228Armed Forces Radiobiology TRIGA 1,100 R-84 Research Institute 06/26/1962 05000170 Bethesda, MD Dow Chemical Company TRIGA 300 R-108 Midland, MI 07/03/1967 05000264 GE-Hitachi Tank 100 R-33 Sunol, CA 10/31/1957 05000073 Idaho State University AGN-201 #103 0.005 R-110 Pocatello, ID 10/11/1967 05000284 Kansas State University TRIGA 250 R-88 Manhattan, KS 10/16/1962 05000188 Massachusetts Institute HWR Reected 6,000 R-37 of Technology 06/09/1958 05000020 Cambridge, MA
Missouri University of Science Pool 200 R-79 and Technology 11/21/1961 05000123 Rolla, MO National Institute of Nuclear Test 20,000 TR-5 Standards & Technology 05/21/1970 05000184 Gaithersburg, MD North Carolina State University Pulstar 1,000 R-120 Raleigh, NC 08/25/1972 05000297 Ohio State University Pool 500 R-75 Columbus, OH 02/24/1961 05000150Oregon State University TRIGA Mark II 1,100 R-106 Corvallis, OR 03/07/1967 05000243 Pennsylvania State University TRIGA 1,100 R-2 State College, PA 07/08/1955 05000005Purdue University Lockheed 12 R-87 West Lafayette, IN 08/16/1962 05000182 Reed College TRIGA Mark I 250 R-112 Portland, OR 07/02/1968 05000288 124 Rensselaer Polytechnic Institute Critical Assembly 0.1 CX-22 Troy, NY 07/03/1964 05000225 Rhode Island Atomic GE Pool 2,000 R-95 Energy Commission 07/23/1964 05000193 Narragansett, RITexas A&M University AGN-201M #106 0.005 R-23 College Station, TX 08/26/1957 05000059Texas A&M University TRIGA 1,000 R-83 College Station, TX 12/07/1961 05000128 U.S. Geological Survey TRIGA Mark I 1,000 R-113 Denver, CO 02/24/1969 05000274University of California/Davis TRIGA 2,300 R-130 Sacramento, CA 08/13/1998 05000607University of California/Irvine TRIGA Mark I 250 R-116 Irvine, CA 11/24/1969 05000326 University of Florida Argonaut 100 R-56 Gainesville, FL 05/21/1959 05000083 University of Maryland TRIGA 250 R-70 College Park, MD 10/14/1960 05000166 University of Massachusetts/Lowell GE Pool 1,000 R-125 Lowell, MA 12/24/1974 05000223 University of Missouri/Columbia Tank 10,000 R-103 Columbia, MO 10/11/1966 05000186 University of New Mexico AGN-201M #112 0.005 R-102 Albuquerque, NM 09/17/1966 05000252University of Texas TRIGA Mark II 1,100 R-129 Austin, TX 01/17/1992 05000602 University of Utah TRIGA Mark I 100 R-126 Salt Lake City, UT 09/30/1975 05000407 University of Wisconsin TRIGA 1,000 R-74 Madison, WI 11/23/1960 05000156Washington State University TRIGA 1,000 R-76 Pullman, WA 03/06/1961 05000027 Note: Data are current as of July 2017; the next printed update will be in August 2018.
APPENDIX HOperating Nuclear Research and Test Reactors Regulated by the NRC (continued)
Licensee Reactor Type Power Level Licensee Number Location OL Issued (kW) Docket Number 125 APPENDIX INuclear Research and Test Reactors under Decommissioning Regulated by the NRC Licensee Reactor Type OL Issued Location Power Level (kW)
Shutdown General Atomics TRIGA Mark F 07/01/60 San Diego, CA 1,500 09/07/94 General Atomics TRIGA Mark I 05/03/58 San Diego, CA 250 12/17/96 General Electric Company GETR (Tank) 01/07/59 Sunol, CA 50,000 06/26/85 University of Buffalo Pulstar 03/24/61 Buffalo, NY 2,000 07/23/96 Note: Data are current as of July 2017; the next printed update will be in August 2018.
APPENDIX J Radiation Doses and Regulatory Limits
126 APPENDIX K Materials Licenses by State Number of Licenses State NRCAgreement States Alabama 16 388 Alaska 66 0 Arizona 11 339 Arkansas 6 208California 59 1,762 Colorado 19 319 Connecticut 138 0Delaware 43 0 District of Columbia 32 0 Florida 26 1,620Georgia 22 414 Hawaii 58 0 Idaho 73 0 Illinois 32 625 Indiana 239 0 Iowa 2 164 Kansas 13 272 Kentucky 12 364 Louisiana 10 459 Maine 4 103 Maryland 82 537 Massachusetts 31 424 Michigan 430 0 Minnesota 15 136 Mississippi 7 286 Missouri 246 0 Montana 84 0 Nebraska 5 140 Nevada 2 242New Hampshire 3 86 New Jersey 35 573 Number of Licenses State NRCAgreement States New Mexico 13 214New York 22 1,310North Carolina 24 578 North Dakota 4 89 Ohio 41 593 Oklahoma 16 231Oregon 5 271 Pennsylvania 46 631 Rhode Island 2 44South Carolina 15 364 South Dakota 36 0Tennessee 22 526Texas 47 1,493 Utah 10 190Vermont 33 0Virginia 57 398Washington 16 332West Virginia 161 0 Wisconsin 12 292 Wyoming 87 0 Puerto Rico 117 0Virgin Islands 8 0 Guam 7 0Total number of materials licenses in Agreement State jurisdiction 17,017Total number of materials licenses in NRC jurisdiction 2,622Total number of materials licenses
in the United States 19,639Notes: The NRC and Agreement State data are as of July 2017. These totals represent an estimate because the number of speci~c radioactive materials licenses per State may change daily. Data are current as of July 2017.
The next printed update will be in August 2018.The NRC licenses Federal agencies in Agreement States.Agreement State Letter of Intent Draft Application 127 APPENDIX L Major U.S. Fuel Cycle Facility Sites Licensee Location Status Docket #Uranium Hexauoride Conversion FacilityHoneywell International, Inc.Metropolis, IL active 04003392 Uranium Fuel Fabrication Facilities Global Nuclear Fuel-Americas, LLC Wilmington, NC active 07001139Westinghouse Electric Company, LLC Columbia Fuel Fabrication Facility Columbia, SC active 07001151 Nuclear Fuel Services, Inc.
Erwin, TN active 07000143BWXT Nuclear Operations Group, Inc.Lynchburg, VA active 07000027AREVA , Inc.Richland, WA active 07001257 Mixed-Oxide Fuel Fabrication FacilityCB&I AREVA MOX Services, LLC Aiken, SCconstruction 07003098 Gas Centrifuge Uranium Enrichment Facilities Centrus Energy Corp.
Lead Cascade: Test and Demonstration Facility Piketon, OHtransitioning into decommissiong 07007003Centrus Energy Corp American Centrifuge Plant Piketon, OHlicense issued, construction halted 07007004URENCO-USA (Louisiana Energy Services)
Eunice, NM active 07003103AREVA Enrichment Services, LLC Eagle Rock Enrichment Facilities Idaho Falls, IDlicense issued,*
construction not started 07007015 Laser Separation Enrichment Facility GE-Hitachi Global Laser Enrichment, LLC Wilmington, NClicense issued, construction not started 07007016 Uranium Hexauoride Deconversion FacilityInternational Isotopes, Inc.
Hobbs, NM (Lea County)license issued, construction not started 04009086* Operating and producing enriched uranium while undergoing further phases of construction.Note: Data are current as of July 2017; the next printed update will be in August 2018.
128Vendor Docket # Storage Design Model General Nuclear Systems, Inc.
07201000 CASTOR V/21 (expired)NAC International, Inc.
07201002 NAC S/T (expired) 07201003 NAC-C28 S/T (expired) 07201015 NAC-UMS 07201025 NAC-MPC 07201031 Magnastor 07201013 NAC-STCHoltec International 07201008 HI-STAR 100 07201014 HI-STORM 100 07201032 HI-STORM FW 07201040 HI-STORM UMAXEnergySolutions, Inc.
07201007 VSC-24 07201026 Fuel Solutions TM (WSNF-220, -221, -223)
W-150 Storage Cask W-100 Transfer Cask W-21, W-74 CanistersTransnuclear, Inc.
07201005 TN-24 (expired) 07201027 TN-68 07201021 TN-32 07201004 Standardized NUHOMS
-24P, -24PHB, -24PTH, -32PT, -32PTH1, -37PTH, -52B, -61BT, -61BTH, -69BTH 07201029 Standardized Advanced NUHOMS
-24PT1, -24PT4 07201030 NUHOMS HD-32PTH Note: Data are current as of July 2017; the next printed update will be in August 2018. (See latest list on the NRC Web site at https://www.nrc.gov/waste/spent-fuel-storage/designs.html.
)APPENDIX M Dry Spent Fuel Storage Designs:
NRC-Approved for Use by General Licensees 129 Arkansas Nuclear GL Energy Solutions, Inc.
VSC-24 07200013 Entergy Nuclear Holtec International HI-STORM 100 Operations, Inc.
Beaver Valley GL Transnuclear, Inc.
NUHOMS-37PTH 07201043 FirstEnergy Nuclear Operating Company Big Rock Point GL Energy Solutions, Inc.
Fuel Solutions TM 07200043 Entergy Nuclear W74 Operations, Inc. Braidwood GL Holtec International HI-STORM 100 07200073 Exelon Generation Co., LLCBrowns Ferry GL Holtec International HI-STORM 100S 07200052 Tennessee Valley Authority
Brunswick GL Transnuclear, Inc.
NUHOMS-HD-61BTH 07200006 Carolina Power Co. Byron GL Holtec International HI-STORM 100 07200068 Exelon Generation Co., LLC Callaway GL Holtec International HI-STORM UMAX 07201045 Union Electric Co.
Ameren Missouri Calvert Cliffs SL Transnuclear, Inc.
NUHOMS-24P 07200008 Calvert Cliffs Nuclear NUHOMS-32P Power Plant, Inc.
Catawba GL NAC International, Inc.
NAC-UMS 07200045 Duke Energy Carolinas, LLC Columbia Generating GL Holtec International HI-STORM 100 07200035 Station Energy Northwest Comanche Peak GL Holtec International HI-STORM 100 07200074 Luminant Generation Company, LLC Cook GL Holtec International HI-STORM 07200072 Indiana/Michigan Power Cooper Nuclear Station GL Transnuclear, Inc.
NUHOMS-61BT 07200066 Nebraska Public Power District
Davis-Besse GL Transnuclear, Inc.
NUHOMS-24P 07200014 FirstEnergy Nuclear Operating Company Diablo Canyon SL Holtec International HI-STORM 100 07200026 Paci~c Gas & Electric Co.
Dresden GL Holtec International HI-STAR 100 07200037 Exelon Generation HI-STORM 100 Company, LLC APPENDIX N Dry Cask Spent Fuel Storage Licensees Name License Storage Docket Licensee Type Vendor Model Number 130Duane Arnold GL Transnuclear, Inc.
NUHOMS-61BT 07200032 NextEra Energy Inc. Duane Arnold, LLC Fermi GL Holtec International HI-STORM 100 07200071 DTE Electric Company Fort Calhoun GL Transnuclear, Inc.
NUHOMS-32PT 07200054 Omaha Public Power DistrictFort St. Vrain*
SL FW Energy Modular Vault 07200009 U.S. Department of Energy Applications, Inc.
Dry Store Ginna GL Transnuclear, Inc.
NUHOMS-32PT 07200067 Constellation Energy Grand Gulf GL Holtec International HI-STORM 100S 07200050 Entergy Nuclear Operations, Inc.
H.B. Robinson SL Transnuclear, Inc.
NUHOMS-7P 07200003 Carolina Power &
GL Transnuclear, Inc.
NUHOMS-24P 07200060 Light Company Haddam Neck GL NAC International, Inc.
NAC-MPC 07200039 CT Yankee Atomic Power Hatch GL Holtec International HI-STAR 100 07200036 Southern Nuclear HI-STAR 100 Operating, Inc.
Hope Creek/Salem GL Holtec International HI-STORM 100 07200048 PSEG Nuclear, LLC
Humboldt Bay SL Holtec International HI-STORM 100HB 07200027 Paci~c Gas & Electric Co.
Idaho National Lab SL Transnuclear, Inc.
NUHOMS-12T 07200020 TMI-2 Fuel Debris, U.S. Department of Energy Idaho Spent Fuel Facility SL Foster Wheeler Concrete Vault 07200025 Environmental Corp.
Indian Point GL Holtec International HI-STORM 100 07200051 Entergy Nuclear Operations, Inc.
James A. FitzPatrick GL Holtec International HI-STORM 100 07200012 Entergy Nuclear Operations, Inc. Joseph M. Farley GL Transnuclear, Inc.
NUHOMS-32PT 07200042 Southern Nuclear Operating Co.
Kewaunee GL Transnuclear, Inc.
NUHOMS-39PT 07200064 Dominion Energy Kewaunee, Inc. La Salle GL Holtec International HI-STORM100 07200070 Exelon Generation Co., LLC APPENDIX N Dry Cask Spent Fuel Storage Licensees (continued)
Name License Storage Docket Licensee Type Vendor Model Number 131Lacrosse GL NAC International, Inc.
NAC-MPC 07200046 Dairyland Power Limerick GL Transnuclear, Inc.
NUHOMS-61BT 07200065 Exelon Generation Co., LLC
Maine Yankee GL NAC International, Inc.
NAC-UMS 07200030 Maine Yankee Atomic Power Company McGuire GL Transnuclear, Inc.
TN-32 07200038 Duke Energy, LLC Millstone GL Transnuclear, Inc.
NUHOMS-32PT 07200047 Dominion Generation
Monticello GL Transnuclear, Inc.
NUHOMS-61BT 07200058 Northern States Power NUHOMS-61BTH Co., Minnesota
Nine Mile Point GL Transnuclear, Inc.
NUHOMS-61BT 07201036 Constellation Energy
North Anna GL Transnuclear, Inc.
NUHOMSHD32PTH 07200056 Virginia Dominion Generation SL Transnuclear, Inc.
TN-32 07200016 Oconee SL Transnuclear, Inc.
NUHOMS-24P 07200004 Duke Energy Company GL Transnuclear, Inc.
NUHOMS-24P 07200040Oyster Creek GL Transnuclear, Inc.
NUHOMS-61BT 07200015 AmerGen Energy Company, LLC Palisades GL EnergySolutions, Inc.
VSC-24 07200007 Entergy Nuclear NUHOMS-32PT Operations, Inc.
Palo Verde GL NAC International, Inc.
NAC-UMS 07200044 Arizona Public Service Co. Peach Bottom GL Transnuclear, Inc.
TN-68 07200029 Exelon Generation Co., LLC Perry GL Holtec International HI-STORM 07200069 FirstEnergy Pilgrim GL Holtec International HI-STORM 100 07201044 Entergy Nuclear Operations, Inc.
Point Beach GL EnergySolutions, Inc.
VSC-24 07200005 FLP Energy NUHOMS-32PT Point Beach, LLC Prairie Island SL Transnuclear, Inc.
TN-40 HT 07200010 Northern States Power TN-40 Co., Minnesota
Private Fuel Storage SL Holtec International HI-STORM 100 07200022 Facility Quad Cities GL Holtec International HI-STORM 100S 07200053 Exelon Generation Co., LLC APPENDIX N Dry Cask Spent Fuel Storage Licensees (continued)
Name License Storage Docket Licensee Type Vendor Model Number 132 APPENDIX N Dry Cask Spent Fuel Storage Licensees (continued)
Name License Storage Docket Licensee Type Vendor Model Number Rancho Seco SL Transnuclear, Inc.
NUHOMS-24P 07200011 Sacramento Municipal Utility District River Bend GL Holtec International HI-STORM 100S 07200049 Entergy Nuclear Operations, Inc.
Salem GL Holtec International HI-STORM 07200048 PSEG Nuclear San Onofre GL Transnuclear, Inc.
NUHOMS-24PT 07200041 Southern California Edison Co.
Seabrook GL Transnuclear, Inc.
NUHOMS-HD-32PTH 07200061 FPL Energy
Sequoyah GL Holtec International HI-STORM 100 07200034 Tennessee Valley Authority
St. Lucie GL Transnuclear, Inc.
NUHOMS-HD-32PTH 07200061 Florida Power & Light Co.
Summer GL Holtec International HI-STORM FW 07201038 South Carolina Electric & Gas Surry SL Transnuclear, Inc.
NUHOMSHD 07200002 Virginia Dominion Generation GL NUHOMSHD-32PTH 07200055 Susquehanna GL Transnuclear, Inc.
NUHOMS-52B 07200028 Susquehanna Nuclear, LLC NUHOMS-61BT NUHOMS-61BTHTrojan SL Holtec International HI-STORM 100 07200017 Portland General Electric Corp.
Turkey Point ISFSI GL Transnuclear, Inc.
NUHOMS-HD-32PTH 07200062 Florida Power & Light Co.
Vermont Yankee GL Holtec International HI-STORM 100 07200059 Entergy Nuclear Operations, Inc.
Vogtle GL Holtec International HI-STORM 100S 07201039 Southern CompanyWaterford Steam GL Holtec International HI-STORM 100 07200075 Electric Station Entergy Nuclear
Operations, Inc.Watts Bar GL Holtec International HI-STORM FW 07201048 Tennessee Valley AuthorityYankee Rowe GL NAC International, Inc.
NAC-MPC 07200031 Yankee Atomic Electric Zion GL NAC International, Inc.
Magnastor 07201037 Zion Solutions, LLC* Fort St. Vrain is undergoing decommissioning and was transferred to DOE on June 4, 1999.Notes: NRC-abbreviated unit names. Data are current as of July 2017, and the next printed update will be in August 2018.
License Types: SL = site-speci~c license, GL = general license 133 Appalachian CompactDelaware Maryland Pennsylvania West Virginia Atlantic Compact
Connecticut New Jersey South Carolina*
Central Compact
Arkansas Kansas Louisiana Oklahoma Central Midwest Compact
Illinois Kentucky Midwest Compact Indiana Iowa Minnesota Missouri Ohio Wisconsin Northwest Compact Alaska Hawaii Idaho Montana Oregon Utah* Washington*
Wyoming Rocky Mountain Compact Colorado Nevada New Mexico (Northwest accepts Rocky Mountain waste as agreed between compacts.)
Southeast Compact
Alabama Florida Georgia Mississippi Tennessee VirginiaSouthwestern Compact
Arizona California North Dakota South Dakota Texas Compact Texas* Vermont Unaf~liated District of Columbia Maine Massachusetts Michigan Nebraska New Hampshire New York North Carolina Puerto Rico Rhode IslandBeatty, NV, closed 1993 Shef~eld, IL, closed 1978 Maxey Flats, KY, closed 1977 West Valley, NY, closed 1975 APPENDIX OU.S. Low-Level Radioactive Waste Disposal Compact Membership Closed Low-Level Radioactive Waste Disposal Facility Sites Licensed by the NRC or Agreement States* Site of an active low-level waste disposal facility.Note: Data are current as of July 2017; the next printed update will be in August 2018.
134 Company Location Alameda Naval Air Station Alameda, CABWX Technology, Inc., Shallow Land Disposal Area Vandergrift, PABeltsville Agricultural Research Center Beltsville, MDCimarron Environmental Response Trust Cimarron, OKDepartment of Army, Jefferson Proving Ground Madison, INDepartment of Army, Picatinny Arsenal (ARDEC)
Picatinny, NJ FMRI, Inc. (Fansteel)
Muskogee, OKHunter's Point Naval Shipyard San Francisco, CAMcClellan Air Force Base Sacramento, CA Sigma Aldrich Maryland Heights, MOUNC Naval Products New Haven, CTWest Valley Demonstration Project West Valley, NYWestinghouse Electric Corporation-Hematite Festus, MONotes: Data are current as of July 2017. The next printed update will be in August 2018. Beltsville Agricultural Research Center, U.S. Department of Army, Picatinny Arsenal, and UNC Naval Products are managed by the NRC's Region I of~ce.
APPENDIX P NRC-Regulated Complex Materials Sites Undergoing Decommissioning, 2016
- NRC-regulated complex materials sites (13) 135 APPENDIX Q Nuclear Power Units by Nation Under Construction In Operation or on Order Gross MW Gross MW Nuclear Power Number Electrical Number Electrical Country Production GWh*
of Units Capacity of Units Capacity ShutdownArgentina 7,677 3 1,700 1 29 0 Armenia 2,195 1 408 0 0 1 P Belarus 0 0 0 2 2,218 0 Belgium 41,283 7 6,207 0 0 1 P Brazil 15,864 2 1,990 1 1,350 0 Bulgaria 15,775 2 2,000 0 0 4 P Canada 97,445 19 14,512 0 0 6 P China 210,519 37 34,744 20 23,360 0 Czech Republic 22,730 6 4,160 0 0 0 Finland 22,282 4 2,872 1 1,720 0 France 384,000 58 63,130 1 1,650 12 P Germany 80,070 8 11,357 0 0 28 P Hungary 15,179 4 2,000 0 0 0 India 35,000 22 6,780 5 3,300 0 Iran 5,924 1 1,000 0 0 0 Italy 0 0 0 0 0 4 P Japan 17,453 42 41,482 2 2,756 17 P & 1 L Kazakhstan 0 0 0 0 0 1 PKorea, Republic of 154,253 25 24,181 3 4,200 0 Lithuania 0 0 0 0 0 2 P Mexico 10,272 2 1,615 0 0 0 Netherlands 3,752 1 515 0 0 1 P Pakistan 5,094 4 1,090 3 2,540 0 Romania 10,368 2 1,411 0 0 0 Russia 179,724 35 27,909 7 5,937 6 P Slovakia 13,733 4 1,950 2 992 3 P Slovenia 5,931 1 727 0 0 0 South Africa 15,209 2 1,940 0 0 0 Spain 56,078 7 7,416 0 0 2 P & 1 L Sweden 60,647 10 10,147 0 0 3 P Switzerland 20,303 5 3,485 0 0 1 P 136 Ukraine 80,950 15 13,835 2 2,178 4 P United Arab Emirates 0 0 0 4 5,600 0 United Kingdom 65,149 15 10,362 0 0 30 P United States 805,327 99 105,403 4 5,000 34 P Overview of Worldwide Nuclear Power Reactors-As of May 10, 2017 Nuclear Electricity Supplied (GWh) 2,476,217Net Installed Capacity (MWe) 392,116 Nuclear Power Reactors in Operation 449Nuclear Power Reactors in Long-Term Shutdown 2 Nuclear Power Reactors in Permanent Shutdown 160 Nuclear Power Reactors under Construction 60
- Annual electrical power production for 2016.
P = Permanent Shutdown L = Long-Term Shutdown Notes: Totals include reactors that are operable, under construction, or on order; the country's short-form name is used; and the ~gures are rounded to the nearest whole number. Sources: IAEA Power Reactor Information System Database; analysis compiled by the NRC. For more information go to www.iaea.org/pris/. Data are current as of May 2017; the next printed update will be in August 2018.
APPENDIX Q Nuclear Power Units by Nation (continued)
Under Construction In Operation or on Order Gross MW Gross MW Nuclear Power Number Electrical Number Electrical Country Production GWh*
of Units Capacity of Units Capacity Shutdown In Operation Number Reactor Type of Units Net MWePressurized light-water reactors (PWR) 290 273,856Boiling light-water reactors (BWR) 78 75,323Heavy-water reactors, all types (HWR, PHWR) 49 24,629Light-water-cooled graphite-moderated reactor (LWGR) 15 10,219Gas-cooled reactors, all types (GCR) 14 7,720Liquid-metal-cooled fast breeder reactors (FBR) 3 1,369Total 449 379,261 Note: MWe values rounded to the nearest whole number.Source: IAEA Power Reactor Information System Database, www.iaea.org Compiled by the NRC from IAEA data. Data are current as of April 2015. The next printed update will be in August 2018.
APPENDIX RNuclear Power Units by Reactor Type, Worldwide 137 APPENDIX SNative American Reservations and Trust Lands within a 50-Mile Radius of a Nuclear Power Plant* Tribe is located within the 10-mile emergency preparedness zone of operating reactors.
Notes: This table uses NRC-abbreviated reactor names and Native American Reservation and Trust land names. There are no reservations or Trust lands within 50 miles of a reactor in Alaska or Hawaii. For more information on other Tribal concerns, go to the NRC Web site at https://www.nrc.gov.
NRC-abbreviated reactor names listed. Data are current as of August 2017, and the next printed update will be August 2018.
- Tribe is located within the 10-mile emergency preparedness zone of operating reactors.Note: This table uses NRC-abbreviated reactor names and Native American Reservation and Trust land names. There are no reservations or Trust lands within 50 miles of a reactor in Alaska or Hawaii. For more information on other Tribal concerns, go to the NRC Web site at www.nrc.gov.
NRC-abbreviated reactor names listed. Data as of August 2017, and the next printed update will be be August 2019.
ARIZONA Palo Verde Ak-Chin Indian Community Tohono O'odham Trust Land Gila River Reservation CONNECTICUT Millstone Mohegan Reservation Mashantucket Pequot Reservation Narragansett Reservation Shinnecock Indian NationFLORIDA St. Lucie Brighton Reservation (Seminole Tribes of Florida)
Fort Pierce Reservation Turkey Point Hollywood Reservation (Seminole Tribes of Florida)
Miccosukee Reservation Miccosukee Trust LandIOWA Duane Arnold Sac & Fox Trust Land Sac & Fox ReservationKANSAS Iowa Reservation Iowa Trust LandLOUISIANA River Bend Tunica-Biloxi ReservationMASSACHUSETTS Pilgrim Wampanoag Tribe of Gay Head (Aquinnah)
Trust LandMICHIGAN Palisades Pottawatomi Reservation Matchebenashshewish Band Pokagon Reservation Pokagon Trust Land*
DC Cook Pokagon Reservation Pokagon Trust LandMINNESOTA Monticello Shakopee Community Shakopee Trust Land Mille Lacs Reservation Prairie Island Prairie Island Community*
Prairie Island Trust Land*
Shakopee Community Shakopee Trust LandNEBRASKA Cooper Sac & Fox Trust Land Sac & Fox Reservation Iowa Reservation Iowa Trust Land KickapooNEW YORK FitzPatrick Onondaga Reservation Oneida Reservation Nine Mile Point Onondaga Reservation Oneida ReservationNORTH CAROLINA McGuire Catawba ReservationSOUTH CAROLINA Catawba Catawba Reservation Oconee Eastern Cherokee Reservation Summer Catawba Reservation VIRGINIA Surry Pamunkey ReservationWASHINGTON Columbia Yakama Reservation Yakama Trust Land WISCONSIN Point Beach Oneida Trust Land Oneida ReservationFor the most recent information, go to the Dataset Index Web page at https://www.nrc.gov/reading-rm/doc-collections/datasets/.
138 APPENDIX TStates with Integrated University Grants Program Recipients in FY 2016 Notes: The 2009 Omnibus Appropriations Act authorized the Integrated University Program (IUP) for 10 years for a total of $45 million per year: $15 million each to the U.S. Nuclear Regulatory Commission (NRC), the U.S. Department of Energy, and the National Nuclear Security Administration. The IUP provides grants to academic institutions to support education in nuclear science and engineering to develop a workforce capable of supporting the design, construction, operation, and regulation of nuclear facilities and the safe
handling of nuclear materials. To date, the NRC has awarded 423 IUP grants, including 127 faculty development, 101 scholarship, 119 fellowship, and 76 trade school and community college scholarship grants. More than 100 faculty and 3,200students have received support. The NRC has invested approximately
$9.6 million in its trade school and community college scholarship program to support the development of trade and craft workers in the nuclear industry.
Recipient of Integrated University Grants 139 Action #NameType Issue DateEnforcement Action EA-15-184 Megan, LLC Materials 1/25/16 NOV/CP SL III-$3,500 EA-15-170Wolf Creek Nuclear Operating Corp.
(Wolf Creek 1 )
Reactor 1/27/16Problem SL III EA-15-205Ferrovial Agroman, S.A.
Materials 2/1/16 NOV SL III EA-15-190Whitworth-Muench, Inc.
Materials 2/2/16 NOV SL III IA-15-074Brian F. Quinn Individual 2/8/16 NOV SL III IA-16-010 Erik Simpson Individual 2/16/16 NOV SL III EA-15-221Materials Testing Consultants, Inc.
Materials 2/19/16 NOV SL III EA-15-188Paci~c Soils Engineering & Testing Materials 3/10/16 NOV SL III EA-15-100Entergy Operations, Inc. (Waterford 3 )
Reactor 4/6/162 Con~rmatory Orders result of an ADR mediation EA-15-247Entergy Nuclear Generation Company (Pilgrim 1 )
Reactor 4/11/16Problem SL III EA-15-212C&D Technologies, Inc.
Reactor 4/20/16Con~rmatory Order result of an
ADR mediation EA-15-258Team Industrial Services, Inc.
Materials 4/20/16 NOV SL III EA-15-251Siouxland Urology Center, LLC Materials 4/21/16 NOV SL III EA-16-035Weaver Consultants Group Materials 5/10/16 NOV SL III EA-15-213 Novelis Corporation Materials 5/13/16 NOV/CP SL III-$7,000 IA 15-079 Stephen Mick Individual 5/13/16 NOV SL III EA-15-039Entergy Nuclear Operations, Inc. (Palisades )
Reactor 5/16/16Con~rmatory Order result of an
ADR mediation EA-16-054 FMC & Associates, LLC Materials 5/17/16Problem SL III EA-16-031Wayne County Well Surveys, Inc.
Materials 5/19/16 NOV SL III EA-16-078Curtis-Wright Corporation Materials 5/20/16 NOV SL III IA-15-053Terry LaBue Individual 5/25/16 NOV SL III IA-15-052 Kristen Smith Individual 5/31/16 NOV SL III EA-16-045 Thielsch Engineering, Inc.
Materials 6/1/16Problem SL III EA-15-165 Montana State University Materials 6/24/16 NOV SL III IA-16-018 Curtis Hofer Individual 6/24/16 NOV SL III EA-14-080 CAMPCO, Inc.
Materials 6/26/16Con~rmatory Order result of an
ADR mediation EA-16-098 7NT Enterprises Materials 7/1/16 NOV SL III EA-16-057Exelon Generation Co., LLC (Oyster Creek )
Reactor 7/6/16NOV White SDP ~nding resulting in plant inspections EA-15-173 ACUREN USA Materials 7/7/16Problem/CP SL III-$7,000 IA-16-025Troy Morehead Individual 7/11/16Con~rmatory Order result of an ADR mediation IA-16-026 Kyle Dickerson Individual 7/11/16Con~rmatory Order result of an ADR mediation EA-16-075Patriot Engineering and Environment Materials 7/12/16 NOV/CP SL III-$3,500 EA-16-109MEDSTAR Washington Hospital Center Materials 7/19/16 NOV SL III EA-16-074 QHG of Indiana, Inc.
Materials 7/23/16 NOV SL III EA-16-046Applied Technical Services, Inc.
Materials 7/28/16Problem/CP SL III-$7,000 IA-15-081Justin Hubbard Individual 7/28/16 NOV SL III IA-16-040Martin Ferenc Individual 7/28/16 NOV SL III APPENDIX USigni~cant Enforcement Actions Issued, 2016 Signi~cant (escalated) enforcement actions include notices of violation (NOVs) for severity level (SL)
I, II, or III violations; NOVs associated with inspection ~ndings that the signi~cance determination process (SDP) categorizes as white, yellow, or red; civil penalties (CPs); and enforcement-related orders. The NRC Enforcement Policy also allows related violations to be categorized collectively as a single problem. Escalated enforcement actions are issued to reactor, materials, and individual
licensees; nonlicensees; and fuel cycle facility licensees.
140 APPENDIX USigni~cant Enforcement Actions Issued, 2016 (continued)
EA-16-016AREVA NP, Inc.
Materials 8/4/16Con~rmatory Order result of an ADR mediation EA-16-100 City of Muskegon Materials 8/8/16 NOV SL III EA-16-022FirstEnergy Nuclear Operating Co.
(Davis-Besse )
Reactor 9/1/16Con~rmatory Order result of
an ADR mediation IA-16-039Franklin D. Hayden, Jr.
Individual 9/1/16Problem SL III EA-16-115Consumers Energy Materials 9/14/16 NOV SL III EA-16-128 R.E. Ginna Nuclear Power Plant, LLC Reactor 9/20/16 NOV White SDP ~nding resulting in plant inspections EA-16-135Ontonagon County Road Commission Materials 9/26/16 NOV SL III EA-16-140Ideker, Inc.
Materials 9/27/16 NOV SL III EA-16-010CB&I AREVA MOX Services Fuel Facility 9/28/16 NOV SL III EA-16-097Jenbo USA, LLC Materials 9/29/16NOV SL III; Problem SL III EA-16-051Power Resources, Inc.
Materials 9/30/16Con~rmatory Order result of an ADR mediation IA-16-043Kevin Brainard Individual 9/30/16 NOV SL III EA-16-163Southern Nuclear Operating Co., Inc. (Hatch)
Reactor 10/3/16Con~rmatory Order result of an
ADR mediation EA-16-099Florida Power & Light Co. (Turkey Point 3, Turkey Point 4 )
Reactor 10/10/16 NOV SL III EA-16-136Southern Nuclear Operating Co., Inc.
(Hatch 1 )
Reactor 10/19/16 NOV SL III EA-16-154 CQM, Inc.Materials 11/14/16 NOV SL III EA-16-064Tennessee Valley Authority (Browns Ferry)
Reactor 11/28/16 NOV/CP SL III-$140,000 EA-16-172Hartford Quality Assurance Materials 12/2/16 NOV SL III EA-16-153Lehigh Cement Company, LLC Materials 12/7/16 NOV SL III EA-16-175Northern States Power Company (Monticello)
Reactor 12/12/16NOV White SDP ~nding resulting in plant inspections EA-16-138EMSI Engineering, Inc.
Materials 12/15/16 NOV/CP SL III-$14,000 EA-16-179 Romeo RIM Materials 12/15/16Problem SL III EA-16-168 Paci~c Gas & Electric Co.
(Diablo Canyon 2 )
Reactor 12/28/16 NOV White SDP ~nding resulting in plant inspections EA-13-190 Plus, LLC Materials 5/3/2016 8/8/2016 3 NOV/CP SL III Order Imposing Civil Penalty
of $21,000 EA-15-230Tetra Tech EC, Inc.
Materials 7/28/2016
10/11/2016 NOV/CP SL III-$7,000 Con~rmatory Order result of
an ADR mediation EA-16-055International Cyclotron, Inc.
Materials8/30/2016 11/17/2016NOV/CP SL III-$14,000 Order Imposing Civil Penalty of
$14,000Notes: Reactor facilities in a decommissioning status are listed as materials licensees. The NRC report on Issued Signi~cant Enforcement Actions can be found on the NRC Web site at https://www.nrc.gov/about-nrc/regulatory/enforcement/current.html.
141 APPENDIX VLaws Governing the U.S. Nuclear Regulatory Commission
- 1. Atomic Energy Act of 1954, as amended (Pub. L.83-703)
- 2. Energy Reorganization Act of 1974, as amended (Pub. L.93-438)
- 3. Reorganization Plan No. 1 of 1980, 5 U.S.C., App. 1.
- 5. Nuclear Non-Proliferation Act of 1978 (Pub. L.95-242)
- 6. West Valley Demonstration Project Act of 1980 (Pub. L.96-368)
- 7. Nuclear Waste Policy Act of 1982, as amended (Pub. L.97-425)
- 8. Low-Level Radioactive Waste Policy Amendments Act of 1985 (Pub. L.99-240)
- 9. Energy Policy Act of 1992 (Pub. L. 102-486)
- 10. Energy Policy Act of 2005 (Pub. L. 109-58) Fundamental Laws Governing Civilian Uses of Radioactive Materials Nuclear Materials and Facilities
- 1. Atomic Energy Act of 1954, as amended
- 2. Energy Reorganization Act of 1974, as amended
- 3. Reorganization Plan No. 1 of 1980 Radioactive Waste
- 1. Nuclear Waste Policy Act of 1982, as amended
- 2. Low-Level Radioactive Waste Policy Amendments Act of 1985
- 3. Uranium Mill Tailings Radiation Control Act of 1978 Nonproliferation
- 1. Nuclear Non-Proliferation Act of 1978 Fundamental Laws Governing the Processes of Regulatory Agencies
- 1. Administrative Procedure Act (5 U.S.C. Chapters 5 through 8)
- 2. National Environmental Policy Act 142 APPENDIX WInternational Activities: CONVENTIONS AND TREATIES PERTAINING TO NUCLEAR SAFETY, SECURITY, AND INTERNATIONAL SAFEGUARDS*
- 1. Treaty on the Non-Proliferation of Nuclear Weapons, entry into force on March 5, 1970; the United States (U.S.) is a party to the Treaty
- 2. Treaty for the Prohibition of Nuclear Weapons in Latin America (Tlatelolco Treaty), entry into force for each government individually, the United States is a party to the speci~c protocols appended to the Treaty
- 3. Three to four other treaties specifying nuclear weapons-free zones in Africa, the South Paci~c (Rarotonga), and Southeast Asia, including one being negotiated on the Middle East; the United States is only bound by speci~c protocols
- 4. Convention on Early Noti~cation of a Nuclear Accident, entry into force October 27, 1986; the United States is a party
- 5. Convention on Assistance in the Case of a Nuclear Accident or Radiological Emergency, entry into force February 26, 1987; the U.S. is a party
- 6. Convention on Nuclear Safety, entry into force October 24, 1996; the U.S.
is a party
- 7. Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management, entry into force June 18, 2001, the U.S. is a party
- 8. Convention on the Physical Protection of Nuclear Material (CPPNM), entry into force February 8, 1987; the U.S. is a party
- 9. Amendment to the CPPNM, entry into force May 8, 2016; the U.S. is a party
- 10. Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter, entry into force August 30, 1975; the U.S. is a party (also to amendments in 1978 (incineration), 1978 (disputes), 1980 (list of substances), 1989 (procedures), 1993 (banning dumping of low-level radioactive wastes into sea), 1996 (protocol to replace the 1972 Convention with a more restrictive text regulating the use of the sea as a depository for waste materials)
- 11. Convention on Supplementary Compensation for Nuclear Damage
- 12. Agreement between the United States of America and the Agency for the Application of Safeguards in the United States of America (INFCIRC/288), entry into force December 9, 1980
- 13. Model Protocol Additional to the Agreement Between State(s) and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty for the Prohibition of Nuclear Weapons in Latin America (INFCIRC/366), entry into force April 6, 1989; U.S. is a party
- 14. Protocol Additional to the Agreement between the United States of America and the Agency for the Application of Safeguards in the United States of America (INFCIRC/288/Add. 1), entry into force January 6, 2009
- This excludes arms control agreements.Note: Data are current as of July 2017; the next printed update will be in August 2018.
143 APPENDIX XInternational Activities: LIST OF THE NRC'S PARTICIPATION WITH MULTILATERAL ORGANIZATIONSInternational Commission on Radiological ProtectionInternational Atomic Energy Agency (IAEA)Commission on Safety Standards (CSS)
Emergency Preparedness and Response Standards Committee (EPReSC)Nuclear Safety Standards Committee (NUSSC)
Nuclear Security Guidance Committee (NSGC)
Radiation Safety Standards Committee (RASSC)
Transport Safety Standards Committee (TRANSSC)
Waste Safety Standards Committee (WASSC)Source: http://www-ns.iaea.org/committees/
Organisation for Economic Co-operation and Development (OECD) specialized agency Nuclear Energy Agency (NEA)
Steering Committee for Nuclear Energy
The Committee on the Safety of Nuclear Installations (CSNI)
The Committee on Nuclear Regulatory Activities (CNRA)
The Radioactive Waste management Committee (RWMC)The Committee on Radiation Protection and Public Health (CRPPH)
The Nuclear Law Committee (NLC)
Multinational Design Evaluation Programme (MDEP)Source: https://www.oecd-nea.org/general/about/committee.htmlUnited Nations Scienti~c Committee on the Effects of Atomic Radiation (UNSCEAR)
UNSCEAR reports to the United Nations General Assembly. It assesses global levels and effects of ionizing radiation and provides a scienti~c basis for radiation protection.Source: http://www.unscear.org/
144BILATERAL INFORMATION EXCHANGE AND COOPERATION AGREEMENTS WITH THE NRCNotes: The country's short-form name is used. The NRC's technical arrangements are initiated and renewed for 5-year terms.Data are current as of July 2017; the next printed update will be in August 2018.EURATOM is the European Atomic Energy Community.Tecro (Taiwan) is the Taipei Economic and Cultural Representative Of~ce in the United States.
Argentina Armenia Australia Belgium Brazil Bulgaria Canada China Croatia Czech Republic
Finland France Germany Greece Hungary India Indonesia
Israel Italy Japan Jordan Kazakhstan Lithuania
Mexico Netherlands
Philippines
Poland Romania Slovakia Slovenia South Africa South Korea
Spain Sweden Switzerland Tecro (Taiwan)
Thailand Turkey United Arab Emirates
Ukraine United Kingdom Vietnam EURATOMAgreement Country APPENDIX XInternational Activities: (continued) 145 APPENDIX YInternational Activities:LIST OF IMPORT AND EXPORT LICENSES ISSUED FOR 2016 License Number Applicant Docket Number PXB114.04 Baker Hughes Oil~eld Operations 11006026 PXB139.03Schlumberger Technology 11006027 PXB14b.06Source Production & Equipment Co., Inc.
11006034 PXB169.02 Baker Hughes Oil~eld Operations 11006064 PXB17b.10 Industrial Nuclear Company 11006012 PXB208.01Halliburton Energy Services, Inc.
11006226 PXB209.00 Karmanos Cancer Center 11006232 PXB210.00Halliburton Energy Services, Inc.
11006245 PXB212.00University of Kentucky, Radiation Safety Of~ce 11006250 PXB3.08Nordion (Canada), Inc.
11006070 PXB6.20 Alpha Omega Services 11006027 PXB6.21 Alpha Omega Services 11006027 License Number Applicant Docket Number IW016/03Eastern Technologies, Inc.
11006602 IW017/03EnergySolutions 11005621 IW033 Perma-Fix Northwest Richland, Inc. (PFNW) 11006229 XB1329/03 Rapiscan Systems, Inc.
11005838 XCOM1209/01Enrichment Technology US, Inc.
11006127 XCOM1228/01 Flowserve US, Inc.
11005934 XCOM1255/01Westinghouse Electric Company, LLC 11006060 XCOM1274Holtec International 11006128 XCOM1295Technetics Group Columbia 11006208 XCOM1296Technetics Group Columbia 11006209 XCOM1297NDA Technologies Incorporated 11006196 XCOM1298Westinghouse Electric Company, LLC 11006217 XCOM1299ATI Specialty Alloys and Components 11006218 XCOM1300Mirion Technologies (IST) Corporation 11006221 XCOM1301 Materion Brush, Inc.
11006222 XCOM1302Harper International Corp.
11006223 XCOM1303 Materion Brush, Inc.
11006227 XCOM1305 Materion Brush, Inc.
11006242Appendix P licenses support the use of radioactive sealed sources for a variety of medical, industrial, research, and educational activities. Some applicants have previously obtained a combined export/import license to allow export or import, use, resale, and import or export back to the supplier for recycling. These combined licenses are no longer appropriate and can no longer be amended going forward, given the authorization for imports of Appendix P materials under a general license (see 10 CFR 110.27, "General License for Import"). These combined import/export licenses needing amendment are converted to export-only licenses. The 2010 changes to 10 CFR Part 110 generally necessitate speci~c licenses for only Appendix P, Category 1 and 2 exports.LIST OF IMPORT AND EXPORT LICENSES: NON-APPENDIX P 146 XCOM1307 Materion Brush, Inc.
11006247XMAT415/02Linde Electronics and Specialty Gases, a Division of Linde Gas North America, LLC 11005907XMAT418/02 Sigma-Aldrich Co., LLC 11005977XMAT419/02 Cambridge Isotope Laboratories, Inc.
11005993XMAT419/02-R Cambridge Isotope Laboratories, Inc.
11005993XMAT424Graftech International Holdings, Inc.
11006032XMAT436 Cambridge Isotope Laboratories, Inc.
11006225XMAT437Linde Electronics and Specialty Gases, a Division of Linde Gas North America, LLC 11006238 XR178Westinghouse Electric Company, LLC 11006216 XSNM3643/02 TN Americas, LLC 11005864 XSNM3722/01AREVA, Inc.
11006109 XSNM3747/02AREVA, Inc.
11006110 XSNM3754 Thermo Fisher Scienti~c 11006166 XSNM3757U.S. Department of Energy-National Nuclear Security Administration 11006187 XSNM3763/01Edlow International Co.
11006195 XSNM3766Edlow International Co.
11006219 XSNM3767Louisiana Energy Services, LLC 11006224 XSNM3767-RLouisiana Energy Services, LLC 11006224 XSNM3768Edlow International Co.
11006228 XSNM3770Edlow International Co.
11006234 XSNM3770-REdlow International Co.
11006234 XSNM3773 Global Nuclear Fuel-Americas, LLC 11006237 XSOU8780/07AREVA Nuclear Materials, LLC 11005211 XSOU8798/06 RSB Logistic Services, Inc.
11005445 XSOU8826/01Honeywell International, Inc.
11005938 XSOU8840Iluka Resources, Inc.
11006220 XW010/03 Duratek Services, Inc.
11005620 XW016/02Eastern Technologies, Inc.
11005825 XW022 Perma-Fix Northwest Richland, Inc. (PFNW) 11006230 License Number Applicant Docket Number Non-Appendix P Components Guide (XSNM) denotes export of special nuclear material (plutonium, uranium-233, or uranium enriched above 0.711 percent, by weight, in the isotope uranium-235).(XCOM) denotes export of minor reactor components or other nuclear facility (e.g., nuclear fabrication) components under NRC jurisdiction (refer to Title 10 CFR Part 110, "Export and Import of Nuclear Equipment and Material", Appendix A, Items (5)-(9), for minor reactor components and Appendices B-K and N-O for other nuclear facility
components).(XSOU) denotes export of source material (natural or depleted uranium; thorium; a mixture of uranium and thorium other than special nuclear material; or certain ores [e.g., tantalum and niobium that contain, by weight, 0.05 percent or more of the aforementioned materials for nonnuclear end use]).(XB) denotes export of byproduct material, 10 CFR Part 110, Appendix L, for an illustrative list of byproduct materials under NRC jurisdiction.(XR) denotes export of reactor facilities, 10 CFR Part 110, Appendix A, items (1)-(4).(IW) denotes import of radioactive waste.
(XW) denotes export of radioactive waste.
APPENDIX YInternational Activities: (continued)LIST OF IMPORT AND EXPORT LICENSES: NON-APPENDIX P (continued) 147