~~cczr,za~rzo o~smreurrow ozvroi~sra~nox svsrsvr f~
REGULAT Y INFORMATION DISTRIBUTIO YSTEM (RIDS) i,
'ACCESSION NBR~9211100063 DOC.DATE: 92/10/31 NOTARIZED: NO DOCKET FACIL:STN-50-530 Palo Verde Nuclear Station, Unit 3, Arizona Publi 05000530 AUTH.NAME AUTHOR AFFILIATION LEVINEgJ.M.
Arizona Public Service Co. (formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Forwards Special Rept 3-SR-92-005,discussing SG tube plugging.ISI of both SGs completed on 921023 6 resulted in plugging of 23 tubes in SG 1
a zero tubes in SG 2.
DISTRIBUTION CODE:
A047D COPIES RECEIVED:LTR ENCL H SIZE-TITLE: OR Submittal: Inservice Inspection/Testing/Relief'rom ASME Code NOTES:Standardized plant.
05000530 RECIPIENT ID CODE/NAME PD5 LA TRAMMELLiC INTERNAL: ACRS NRR/DET/EMEB 7E OC/LFMB EXTERNAL: EGGG BROWNiB NRC PDR COPIES LTTR ENCL 1
0 2
2 6
6 1
1 1
0 1
1 1
1 1
1 1
RECIPIENT ID CODE/NAME PD5 PD NRR/DET/ECMB 9H NUDOCS-ABSTRACT OGC/HDS1 RES MILLMAN,G EGGG RANSOMEgC NSIC COPIES LTTR ENCL 1
1 1
1 1
1 1
0 1
1 1
1 1
1 NOTE TO ALL "RIDS RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.
ROOM Pl-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 22 ENCL 19
f
JAMES M. LEVINE VICE PRESIDENT NUCLEAR PRODUCTION Arizona Public Service Company PALO VERDE NUCLEAR GENERATING STATION P.O. BOX 52034
~
PHOENIX. ARIZONA85072-2034 192-00805-JML/TRB/KR October 31, 1992 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Mail Station P1-37 Washington, D.C. 20555
Dear Sirs:
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Unit 3 Docket No. STN 50-530 (License No. NPF-74)
Special Report 3-SR-92-005 File: 92-020-404 Attached please find Special Report 3-SR-92-005 prepared and submitted pursuant to Technical Specification (TS) Surveillance Requirement 4.4.4.5.a and TS 6.9.2.
This report discusses steam generator tube plugging in Unit 3. A copy of the Special Report is being forwarded to the Regional Administrator, NRC Region V.
If you have any questions, please contact T. R. Bradish, Manager, Nuclear Regulatory Affairs, at (602) 393-5421.
Sincerely, JML/TRB/KR Attachment cc:
W. F. Conway (all with attachment)
J. B. Martin J. A. Sloan i
9211100063 921031 PDR.
ADOCK 05000530 8
pt tg
PALO VERDE NUCLEAR GENERATING STATION UNIT 3 STEAM GENERATOR TUBE PLUGGING DOCKET NO. STN 50-530 LICENSE NO. NPF-74 SPECIAL REPORT NO. 3-SR-92-005 This Special Report is being provided pursuant to Palo Verde Unit 3 Technical Specification (TS) Surveillance Requirement 4.4.4.5.a and TS 6.9.2 to report the number of steam generator tubes plugged as a result of inservice inspection activities.
On October 23, 1992, Unit 3 was in a refueling outage with the core off-loaded to the Spent Fuel Pool when an inservice inspection of both steam generators was completed.
The inspection resulted in the plugging of twenty-three (23) tubes in Steam Generator No.
1 and zero (0) tubes in Steam Generator No. 2.
Pursuant to Technical Specification 4.4.4.5.b, the complete results of the steam generator tube inservice inspection will be submitted by October 23, 1993.
'a
~