FLORIDA POWER 6
LIGHT COMPANY ST.
LUCIE PLANT OPERATING PROCEDURE NO. 0520023 REVISION 0
1.0 Title
Dewatering Radioactive Bead Resins 2.0 Review and A
royal:
Reviewed by Facility Review Group Approved by Plant Manager March 1
1983 1983 Revision Reviewed by F R G
Approved by Plant Manager
~ 19t3, 3.0
~Per tee:
This procedure provides instructions for the dewatering of radioactive bead resins from St. Lucie Unit No.
1 and St. Lucie Unit No.
2 for disposal at a low level radioactive waste disposal facility.
'4.0 Limits and Precautions:
4.1 Full scale testing must be provided for all containers used to dispose of dewatered radioactive bead resins in accordance with Administrative Procedure No. 0520025.
4.2 Disposal of dewatered radioactive bead resin is limited to the following containers:
4.2.1 CNSI Conical Bottom EnviroSAFE'High Integrity Container type PL6-80CR.
4.2.2 CNSI Conical Bottom EnviroSAFE'High Integrity Container type PL14-195CR.
4.3 The maximum allowable free standing liquid allowed in radioactive waste is 1X.
4.4 The following limits apply for disposal of radioactive bead resin at the Barnwell Waste Management Facility:
4.4.1 Dewatered radioactive bead resins.may be disposed of in High Integrity Containers pursuant to the Barnwell Site Criteria.
Free standing liquids must be less than 1X of the waste volume.
(
8304200233 83041 3 R ADOCK 05000335 PDR
C f
ST.
LUCIE PLANT
~
~
OPERATING PROCEDURE NO. 0520023, REVISION 0
DEWATERING RADIOACTIVE BEAD RESINS 4.0 Limits and Precautions:
(continued) 4.4 (continued) 4.4.2 Dewatered radioactive bead resin may be disposed of in other containers pursuant to the Barnwell Site Criteria.
Free standing liquids must be less than 0.5X of the waste volume.
4.5 With dewatering not meeting disposal site, shipping, and/or transportation requirements, suspend shipment of the inadequately dewatered bead resin and correct the process control program, the applicable procedure(s),
and/or the dewatering system as necessary to prevent recurrence.
4.6 With dewatering not performed i'n accordance with the PCP:
(1) if the dewatered radioactive bead resin has not already been shipped for disposal, verify each container to ensure that it meets burial ground, shipping and transportation requirements, and/or (2) take appropriate administrative action to prevent recurrence.
5.0 Related S stem Status:
5.1 Instrument Air System available 5.2 Positive displacement, air operated, diaphram pump such as a Warren-Rupp Sandpiper with either 1 1/2" or 2" diameter inlet/outlet connections available.
6.0
References:
6.1 Dewatering Procedure for CNSI Conical-Bottom EnviroSAFE'High Integrity Containers (containing bead-type ion exchange resin) 1X free standing water - FOWP-003.
6.2 Lab Record Sheet for Conical Bottom Demineralizers and Resin Liners, Project No. 11038.
6.3 Test Procedure for Dewatexing Conical Bottom Demineralizers and Resin Liners, Prospect No.
11038.
7.0 Records and Notifications:
CNSI High Integrity Container Dewatering Record to (
1X F.S.W.
ST.
LUCIE PLANT OPERAS NG PROCEDURE
.NO. 0520023~REVISION 0
DEWATERING RADIOACTIVE BEAD RESINS
8.0 Instructions
8.1 Obtain a positive displacement, air-operated, diaphram pump such as a Warren-Rupp Sandpiper with either 1 1/2" or 2" diameter inlet/outlet connections.
8.2 Connect suction of pump to the proper dewatering connection on the resin liner fillhead with a pressure tested hose of at least 1 1/2" in diameter.
8.3 Blow out service airline(s) to clear any trapped liquids and then connect to the dewatering pump.
8.4 Connect discharge line to the pump.. Filter the discharge if required by Chemistry Depratment.
Be aware of potential high exposure rates from filters during dewatering.
Route the discharge of pump to approved drain line; either a floor drain or other radwaste system as approved by Chemistry.
8.6 Perform a functional test of pumps and hose(s) before actual resin bead transfer.
Tighten any leaks.
Bag all connections on suction and discharge hoses.
8.7 Transfer resin to the disposal container.
8.8 Start the dewatering pump as soon as the resin slurry. starts to collect in the liner.
Run pump at a speed of two (2) strokes per, second or faster, avoiding pump cavitation or stalling.
8.9 Continue to dewater throughout transfer of slurry and flushing operations unless requested to stop by the Radwaste Supervisor or the Operations Supervisor.
8.10 When all transfer and flushing operations are complete, close the fillvalves on the fillhead and inside the Drumming Room.
Record the time dewatering started on the attached form.
8.11 Continue to run the dewatering pump for a minimum of eight (8) hours.
Before securing the pump, lift the suction hose so as to remove any pockets of water trapped in the hose.
Stop the pump and record the time on the attached form.
8.12 Let the vessel stand for a minimum of 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />.
- 8. 13 8.)4 Start the dewatering pump and run a >
2 strokes per second and run for at least eight (8) hours.
Remove water trapped in suction hose as before and then
~ secure the pump.
Record times on form.
Let the.vessel stand for a minimum of 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />.
- 8. 15 Obtain a container such as a bucket or drum to catch discharge of pump o CAUTION:
Water will be HIGHLY RADIOACTIVE.
ST.
LUCIE PLANT OPERAT NG PROCEDURE NO ~ 0520023, kEVISI'ON 0
DEWATERING RADIOACTIVE BEAD RESINS
8.0 Instructions
(continued) 8.16 Start the dewatering pump and run for eight (8) hours minimum.
Measure the volume of water collected during the third cycle being sure to remove any water. standing in the suction hose as before.
6.17 If the volume of water collected is greater than 2000 ml, repeat the dewatering cycle of 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> standing and eight hours pumping until less than 2000 ml of water is collected.
8.18 If the volume of water is less than 2000 ml, dewatering is complete.
Record volume of water collected along with start and stop times of dewatering on form.
NOTE:
The dewatering record (i.e.
CNSI High Integrity Container Dewatering Record to ( lX F.S.M.) must be completed and approved by the Radwaste Supervisor.
The completed form must also be included in the shipping papers.
8.19 Disconnect fillhead from liner and ready liner and cask for shipment.
c'i C
ST ~
LUCIE PLANT OPERA NG PROCEDURE NO. 0520023',
REVISION 0
DEWATERING RADIOACTIVE BEAD RESINS C.N.S.I.
HIGH-INTEGRITY CONTAINER DEWATERING RECORD TO (lX F AS.WE Shipment Number Liner Designation Allocation Number Liner Serial Number
~ A.
Start Dewatering Pump Stop Dewatering Pump Total Pumping Time B.
Let vessel stand for >
16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />.
C.
Start Dewatering Pump Stop Dewatering Pump Total Pumping Time D.
Let vessel stand for >
16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />.
DATE
/
/'
/
/
/
/
/
TIME BY B.
Start Dewatering Pump Stop Dewatering Pump Total Pumping Time F.
Volume of water collected
/
/
/
/
G.
Repeat cycle necessary'es No H.
Record of repeat cycles if necessary Comments' Must be
> 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Approved by Radwaste Supervisor
~
o