ML17059B423
| ML17059B423 | |
| Person / Time | |
|---|---|
| Site: | Nine Mile Point |
| Issue date: | 02/07/1997 |
| From: | Hood D NRC (Affiliation Not Assigned) |
| To: | Sylvia R NIAGARA MOHAWK POWER CORP. |
| References | |
| NUDOCS 9702110352 | |
| Download: ML17059B423 (16) | |
Text
~g~P RE00 Cy I
cI0 I
f 1
ft
'i I5g A
l Id l
B. Ralph Sylvia If I can be of further assistance regarding this matter, please call me at 301-415-3049 or Nr. Gerald H. Weidenhamer at 301-415-6015.
Docket No. 50-410 Sincerely, Pwu l~Y Darl Hood, Senior Project Hanager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Enclosures:
1.
Figure 3
2.
Table 1
3.
Instructions cc w/encls:
See next page
\\
B. Ralph Sylvia Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Unit 2 CC:
Mr. Richard B. Abbott Vice President and General Manager Nuclear Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.
Box 63
- Lycoming, NY 13093 Mr. Hartin J.
McCormick, Jr.
Vice President Nuclear Safety Assessment and Support Niagara Mohawk Power Corporation P.O.
Box 63
- Lycoming, NY 13093 Ms. Denise J. Wolniak Manager Licensing Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.
Box 63
- Lycoming, NY 13093 Hr. Kim A. Dahlberg General Manager - Projects Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.
Box 63
- Lycoming, NY 13093 Mr. John T.
Conway Plant Manager, Unit 2 Nine Mile Point Nuclear Station Niagara Mohawk Power Corporation P.O.
Box 63
- Lycoming, NY 13093 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector Nine Mile Point Nuclear Station P.O.
Box 126
- Lycoming, NY 13093 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Richard H. Kessel Chair and-Executive Director State Consumer Protection Board 99 Washington Avenue
- Albany, NY 12210 Hark J. Wetterhahn, Esquire Winston,& Strawn 1400 L Street, NW.
Washington, DC 20005-3502 Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
- Syracuse, NY 13202 Mr. F. William Valentino, President New York State
- Energy, Research, and Development Authority Corporate Plaza West 286 Washington Avenue Extension
- Albany, NY 12203-6399 Supervisor Town of Scriba Route 8, Box 382
- Oswego, NY 13126 Mr. Richard Goldsmith Syracuse University College of Law E. I. White Hall Campus
- Syracuse, NY 12223
= Mr. John V. Vinquist, HATS Inc.
P.O.
Box 63
- Lycoming, NY 13093
0
B. Ralph Sylvia Niagara Hohawk Power Corporation CC:
Nine Mile Point Nuclear Station Unit 2 Nr. Jim Rettberg New York State Electric
& Gas Corporation Corporate Drive Kirkwood Industrial Park-P.O.
Box 5224 Binghamton, NY 13902-5224 Kalsi Engineering, Inc.
745 Park Two Drive Sugar
- Land, Texas 77478
D sp A
V Qp Qp Qp Tr T
1 2
3 4
5 6
P T
QH I
D S
6 QpI QT QH Qi Q2 Qs Qg Qs Q6 Qo Qn Qs QT Qp QA Qv
~eceend Low pressure pump Pressure High pressure pump
~
Temperature Heater Valve position Valve current and power Valve voltage Torque spring deflection and force Stem force and stem torque Motor speed Drain Reservoir D.l. water Motor torque Stem position Airinjection High point vent Q
I Figure 3. Test setup and instrumentation for thc prcssure locking tests.
Gill1hOH 196.AOl
Table 'l. Test'instrumentation.
TCS channel Channel "1 Channel 02 Channel 03 Channel 16 Channel 19 Channel 21 Channel 32 Channel 33 Channel 34 Channel 35 Channel 36 Channel 40 Channel 50 Channel 51 Channel 66 Channel 67 Channel 68 Channel 69 Channel 72 Channel 74 Channel 75 Channel 77 Channel 78 Channel 79 Description Bonnet fiuid temperature Upstream fluid temperature Downstream fluid temperature Motor current, Il, RMS Motor voltage, V1-2, RMS Motor rotor temperature Stem force goad cell)
Torque spring force Bonnet pressure Upstream pressure L wnstream pressure Motor torque Stem force (Smart Stem)
Stem torque (Smart Stem)
Torque switch Motor power Motor power factor Torque spring position Motor speed Transformer voltage Stem position Motor current, II, Peak Motor current, I2, Peak Motor current, I3, Peak Calibration Not required Not required Yes Not required Not required Enclosure 2
PROCESS FOR LOADING DATA FILES The data files contained on disks 1 and 2 are in DADiSP Labbook format.
They have also been compressed using the PKZIP software.
To load the data files into DADiSP, first run DADiSP and create new Labbooks having the same name as each data file.
Note that the "D" at the end of the file name indicates DADiSP format and is not part of the Labbook name.
Example:
For file name V3002D.ZIP, create Labbook V3002 Next, exit DADiSP and enter the DOS subdirectory matching the newly created Labbook.
Examp1e:
CD C:$DSP'+3002 Finally, "unzip" the data ",le that matches the Labbook name.
PKZIP will question if you ~ant to ov write the INDEX.PI file - you must answer YES.
Example:
PKUHZIP A:JV3002D.ZIP The data should now be loaded into the DADiSP Labbook and available for analysis.
Enclosure 3
I l
3