Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:14.1.10B-3 Page:
1 of 1 UNIT 2 TIME SEQUENCE OF EVENTS (FULL V-5 CORE)
Accident Event Time (sec)
Feedwater System Malfunctions:
Excessive feedwater flow at full power to all four steam generators (Manual Rod Control)
All four main feedwater control valves fail fully open 0.0 Hi-hi steam generator water level signal generated 31.5 Turbine trip occurs due to hi-hi steam generator water level 34.0 Minimum DNBR occurs 34.5 Reactor trip occurs due to turbine trip 36.0 Feedwater isolation achieved 42.5