IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
16.1 Table:14.1.2B-1 Page:
1 of 1 Unit 2 TIME SEQUENCE OF EVENTS (FULL VANTAGE 5 CORE)
Accident Event Time (sec)
Uncontrolled RCCA Bank Withdrawal At Full Power Case A: (high insertion rate max feedback)
Initiation of uncontrolled RCCA bank withdrawal at a high reactivity insertion rate (80 pcm/sec) 0 Power range high neutron flux high trip signal initiated 5.8 Rods begin to fall into core 6.3 Minimum DNBR occurs 6.4 Case B: (small insertion rate, max feedback)