ML16015A189

From kanterella
Jump to navigation Jump to search
Official Exhibit - FPL-024E-00-BD01 - Turkey Point Plant; Annual Post-Uprate Monitoring Report, Units 3&4 Uprate Project (August 2014) - Pages 3-1 to 3-55
ML16015A189
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 08/31/2014
From:
Florida Power & Light Co
To:
Atomic Safety and Licensing Board Panel
SECY RAS
References
50-250-LA, 50-251-LA, ASLBP 15-935-02-LA-BD01, RAS 28503
Download: ML16015A189 (55)


Text

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-1

3. QUARTERLY GROUNDWATER AND SURFACE WATER SAMPLING The Monitoring Plan (SFWMD 2009a) and the QAPP (FPL 2013b) for this project outline the locations and analytes for the groundwater and surface water sampling and the analyses for quarterly and semi-annual events. Each groundwater location is a cluster of three wells at different depth intervals. The groundwater wells are designated by depth and are defined as S for shallow wells (-15.3 to -34.7 ft North American Vertical Datum of 1988 [NAVD 88] to bottom of screen elevation), M for intermediate wells (-32.8 to -85.7 ft NAVD 88 to bottom of screen elevation), and D for deep wells (-46.4 to -122.2 ft NAVD 88 to bottom of screen elevation). Surface water samples are also designated by depth, i.e., T for top (1 ft below surface) and B for bottom (1 ft above bottom). Samples also were collected from several of the historical wells that have been monitored as part of the ID operations. Since the historical wells (L-3, L-5, G-21, G-28, and G-35) are screened across the entire well depth, samples were collected from two depths (18 ft and 58 ft below top of casing).

From June 2010 to May 2013, samples were collected quarterly at specified locations and were analyzed for the parameters as required in the Monitoring Plan. In June 2013, after review by the Agencies, several sites and parameters were dropped from the sampling. Three sites (TPBBSW-1B, TPBBSW-2B, and TPSWCCS-6 [B and T]) and two bottom stations (TPSWCCS-4B and TPSWCCS-5B) were eliminated. Per the Agencies, the data reductions (Tables 3.0-1 and 3.0-2) were as follows:

Trace metals analyses were eliminated for the Post-Uprate period.

Stable isotope (carbon (13C), oxygen (18O), hydrogen (D), and strontium(87Sr/86Sr))

analyses were eliminated for the Post-Uprate period.

Cation and anion analyses with the exception of sodium and chloride, were reduced from quarterly to semi-annually.

Sampling logs from June 2013 to March 2014 are provided in Appendix G. Most of the samples were analyzed by TestAmerica; however, tritium analysis was conducted by the USGS Tritium Laboratory. Details of the analytical methodologies for each analyte are provided in the project QAPP.

For the Post-Uprate, several analytical methods were changed because of interference that impacted result accuracy. For example, several ions have been problematic during analysis because of their low concentrations compared to the other peaks in the chromatogram. In the Post-Uprate, fluoride was switched to a probe analysis method due to frequent interference by the chloride peak. Sulfide was another method that was switched because of frequent non-detect values.

United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:

FLORIDA POWER & LIGHT COMPANY (Turkey Point Nuclear Generating, Units 3 and 4)

ASLBP #: 15-935-02-LA-BD01 Docket #: 05000250 & 05000251 Exhibit #:

Identified:

Admitted:

Withdrawn:

Rejected:

Stricken:

Other:

FPL-024E-00-BD01 1/4/2016 1/4/2016 FPL-024E

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-2 During the Post-Uprate, it was determined that bicarbonate alkalinity was being calculated as mg/L as CaCO3 instead of mg/L as HCO3 per the Monitoring Plan. This laboratory calculation affects all values after September 2010; therefore, a correction factor of x1.22 will have to be applied to datasets after September 2010 to adjust results to report as mg/L as HCO3 (TestAmerica 2014).

3.1 GROUNDWATER QUALITY 3.1.1 Sample Collection and Analysis Groundwater samples were collected in accordance with the QAPP and based on FDEP Standard Operating Procedures (SOPs). Figure 3.1-1 shows a typical setup for the groundwater sampling.

Groundwater and surface water sampling logs from June 2013 to March 2014 are included in Appendix G of this report.

3.1.2 Results and Discussion Values in most of the wells have been fairly consistent in the Post-Uprate period and are similar in range to values observed during the Pre-Uprate period. Tables 3.1-1 through 3.1-4 provide a summary of the groundwater analytical results from the June 2013 through May 2014 sampling events. Results for the sampling events from the historical monitoring wells L-3, L-5, G-21, G-28, and G-35 during the same time period are provided in Tables 3.1-5 through 3.1-8. DUS Reports for all events are provided in Appendix H, and the detailed Level IV laboratory reports from TestAmerica are included in Appendix I. A summary of the ionic ranges Pre-and Post-Uprate is provided in Table 3.1-9.

The only notable changes observed were in TPGW-10D and TPGW-7D, and to a lesser degree to TPGW-11D in this Post-Uprate period. Both TPGW-10D and TPGW-7D had higher specific conductance and ionic concentrations relative to the Pre-Uprate period; the ionic increases in TPGW-10D were observed starting in September 2012 during the Interim Operating Period while the increase in TPGW-7D started in September 2013. This is supported by automated monitoring specific conductance values as shown in Figures 2.1-8 and 2.1-11. A slight ionic and specific conductance increase was also observed in TPGW-11D starting in the Interim Operating Period. The more saline water at TPGW-10D and TPGW-11D remain confined at depth and do not appear to be migrating into the upwards. Further assessment of the water in TPGW-7D is pending as tritium data from June 2013 to March 2014 are still being analyzed by the USGS.

3.1.2.1 Chloride, Sodium, and Specific Conductance Figures 3.1-2, 3.1-3, and 3.1-4, and Tables 3.1-1 to 3.1-4 show the chloride, sodium, and specific conductance values for the sampling events from June 2013 through March 2014. There was some seasonal variation but lower than that observed in the surface waters. Within a well cluster, the lowest sodium and chloride values were generally observed in the shallow wells; the only exception to this was at TPGW-13 where the intermediate and deep wells had consistently lower

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-3 values than the shallow well over the monitoring period (Figures 3.1-2 and -3). The new monitoring wells, which were cased at specific intervals, also had lower variability compared to the historical monitoring wells, which are open throughout most of the well length.

Chloride values in TPGW-13 during the Post-Uprate period were similar to the values during the Pre-Uprate period (Table 3.1-9). Similarly, the ranges observed in the Biscayne Bay wells (TPGW-10, TPGW-11, and TPGW-14) showed the same Post-Uprate patterns with the exception of TPGW-10D and, to a lesser extent, TPGW-11D (Table 3.1-9). Both wells showed an increase in chloride concentrations commensurate with the specific conductance increase observed in the automated and other ionic data. During the Pre-Uprate period through February 2012, TPGW-10D chloride values were reflective of marine waters, but starting from September 2012 during the Interim Operating Period, this well now exhibits a mix of marine and some CCS water.

TPGW-11 during the Pre-Uprate had slightly higher chloride values in the intermediate and deep wells relative to the shallow well; the values in the intermediate well have not changed during the Post-Uprate, but chloride concentrations have been increasing in TPGW-11D starting in March 2013 during the Interim Operating Period and into the Post-Uprate.

Terrestrial wells around and to the west of the CCS (TPGW-1 through TPGW-6, TPGW-12, TPGW-L3, TPGW-L5, TPGW-G21, TPGW-G28, and TPGW-G35) had vertical and spatial Post-Uprate sodium, chloride, and specific conductance values similar to those observed during the Pre-Uprate period (Figures 3.1-5, 3.1-6, 3.1-7 and 3.1-8). The range of values observed in the shallow wells or 18 ft depth (in the case of the historical wells) continued to be lower than the samples from depth due to the fresher water lens that overlies the area west of the CCS. This freshwater zone is evident in the upper 20 to 40 ft of the aquifer and increases in depth towards the west; this is supported by the annual USGS induction log results (Appendix E) from the dry season (i.e., April 2014).

Temporally, the chloride, sodium, and specific conductance ranges across the landscape in the shallow wells were not significantly different in the four quarters of Post-Uprate compared to the seven Pre-Uprate events (chloride: F1,150=0.06, P=0.804; sodium: F1,150=0.47, P=0.504; specific conductance: F1,150=1.23, P=0.287). Wells TPGW-7, TPGW-8, and TPGW-9, farthest away from the CCS, were fresh (i.e., less than 500 milligrams per liter [mg/L] chloride and less than 1,275 µS/cm specific conductance) at all depths during the Pre-Uprate period and most of the wells remain fresh during the Post-Uprate. The only exception was TPGW-7D, which showed an increase in chloride, sodium, and specific conductance levels starting in September 2013.

Further assessment of the water in TPGW-7D cannot be conducted as tritium data from June 2013 onwards is still pending.

3.1.2.2 Ions Select ions (calcium, magnesium, potassium, boron, strontium, bromide, fluoride, and sulfate) analysis was reduced to semi-annually beginning in June 2013; sodium and chloride analyses were to continue on a quarterly basis. For the Post-Uprate period, data for both September 2013 and March 2014 are compared against the Pre-Uprate period (quarterly from June 2010 to December 2011). Ionic concentrations at the TPGW sites (Tables 3.1-1 to 3.1-4) appeared to

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-4 correspond with specific conductance values in most of the wells and varied seasonally, i.e.,

lower in the wet season (September 2013) and higher in the dry season (March 2014).

Tri-linear diagrams comparing the Post-Uprate to the Pre-Uprate indicated very little average difference in the overall patterns (Figure 3.1-9). Freshwater sites had low concentrations of ions, while marine-influenced sites generally had higher values. The highest values were observed at TPGW-13 (Table 3.1-9); the ionic chemistry of this site based on the tri-linear diagram showed that for both the Post-Uprate and Pre-Uprate, this station had similar chemistry (i.e., overlapping on the tri-linear diagram) to the marine stations (Figure 3.1-9). The range of values also remained consistent for most of the sites during the Post-Uprate period and Post-Uprate values were consistent with the Pre-Uprate values; the only exceptions were TPGW-7D, TPGW-10D and TPGW-11D which were higher, reflecting the increase in specific conductance observed.

TPGW-8S continues to have high pH (10.77 to 11.86) and high alkalinity (182 to 430 mg/L) in the Post-Uprate, similar to the Pre-Uprate period. The patterns are only observed at this depth at this location, and the alkalinity is mostly due to hydroxide ions indicating a stronger base than found under natural conditions.

3.1.2.4 Nutrients Tables 3.1-2 and 3.1-4 show the nutrient results for the September 2013 and March 2014 sampling events, while Figure 3.1-10 summarizes the data and compares it to the Pre-Uprate range. For the five groundwater sites monitored, nitrogen occurs primarily as ammonia (greater than 60% of total nitrogen [TN]) across the landscape at all depths. The majority (greater than 90%) of the ammonia was in the form of ammonium and this observation was consistent for both the Post-Uprate and Pre-Uprate periods.

Although TN was slightly higher in September 2013 relative to March 2014, both events were within range of the Pre-Uprate data. Nitrogen concentrations were lowest at TPGW-10 and TPGW-14, followed by TPGW-1, TPGW-2, and TPGW-13. Similar to specific conductance, wells at depth generally had higher nutrient concentrations compared to the shallower wells; the only exception was TPGW-13 where the nutrients in the shallow well were either similar to or higher than the wells at depth for both the Pre-and the Post-Uprate periods.

A one-time collection of nutrient data from TPGW-4 through TPGW-9 indicated that the wells were similar to the data from TPGW-10. Wells TPGW-5 and TPGW-7 showed a gradient of increasing TN with depth. TPGW-8S had high ammonia and unionized ammonia as pH>8 will increase the availability of ammonia. Consequently, this high ammonia contributes to high TKN that results in elevated TN. This result may be an artifact of the unusual chemistry of this site and not an influence from the CCS.

Although TP was slightly higher in September 2013 relative to March 2014, overall, average TP during the Post-Uprate (0.038 +/- 0.002 mg/L) in TPGW-13 was lower than in the Pre-Uprate (0.050 +/- 0.006 mg/L; F1,74=40.58; P<0.001). This Pre-Post Uprate trend was also observed in the other groundwater stations.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-5 3.2 SURFACE WATER QUALITY 3.2.1 Sample Collection and Analysis Surface water data were initially collected from 19 locations (33 sites), but this was reduced to 16 locations (27 sites) after Agency review in June 2013 (SFWMD 2013a). A list of the sites eliminated is shown in Section 1. The sampling methods follow Florida Department of Environmental Protection protocols and remain the same as described in the Comprehensive Pre-Uprate Report (FPL 2012); samples are still being collected from 1 ft below the surface (T) and 1 ft above the bottom (B) unless the water depths in the CCS, ID, or canals were less than 3 ft. In Biscayne Bay, regardless of water depth, all samples were collected at depth.

3.2.2 Results and Discussion Tables 3.2-1 through 3.2-4 provide a summary of the surface water analytical results from June 2013 through May 2014. DUS Reports for each event are provided in Appendix H and detailed Level IV laboratory reports from TestAmerica are included in Appendix I. Additionally, the stations have been grouped based on their general characteristics and location, and Table 3.2-5 shows the minimum, maximum, average and standard deviation of these water bodies from June 2013 to March 2014, unless otherwise explicitly stated.

3.2.2.1 Chloride, Sodium, and Specific Conductance Figures 3.2-1, 3.2-2, and 3.2-3 detail chloride, sodium, and specific conductance values for all surface water stations for the June 2013 through March 2014 sampling events. The values observed were highly dependent on the water body, water management practices, and seasonal conditions. Values were generally lower during the wet season and higher during the dry season.

Surface waters with chloride concentrations greater than 1,500 mg/L are defined as predominantly marine, while those with less than 1,500 mg/L are defined as predominantly fresh (F.A.C.62-302.200). The Class II/III criteria for specific conductance in freshwater (excluding consideration of background values) is less than 1,275 µS/cm while values higher than 1,275

µS/cm in a coastal environment are often viewed as potentially having some marine influence.

The highest chloride values were observed in the CCS (27,000 to 49,800 mg/L), with the highest values being observed in March 2014 and the lowest values in June 2013. The values observed during the Post-Uprate (average: 39,008 mg/L) were higher than the Pre-Uprate (average: 34,114 mg/L); however, none of the other surrounding water bodies showed a similar increase. Average chloride levels in other canals, as well as in Biscayne Bay, were lower in the Post-Uprate relative to the Pre-Uprate (which encompassed a drought in the spring of 2011).

Biscayne Bay values were influenced by rainfall, proximity to canal inputs, and water depth.

Consequently, TPBBSW-3 and TPBBSW-4 are more variable compared to TPBBSW-5, which is

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-6 farther south, in deeper water, and not near any inlets to allow exchange with the Atlantic Ocean.

The values in TPBBSW-4 are comparable to TPSWC-5, which is located in the Card Sound Canal, just south of the CCS. This station is connected to the Bay and values reflect the conditions in the Bay. Unlike the Pre-Uprate period where differences of up to 8,000 mg/L were observed between the top and bottom at this location, chloride differences during the Post-Uprate were limited (maximum difference of 1,400 mg/L higher at depth in June 2013).

TPSWC-1, TPSWC-2, TPSWC-3, and TPSWC-6 are all considered freshwater stations based on the average chloride, sodium, and specific conductance values for the Post-Uprate period.

However, during the dry season, the bottom of these stations can have slightly higher values of chloride and sodium compared to the surface. The sodium values during the Post-Uprate were however, lower than the Pre-Uprate values (F1,336=5.44; P=0.030) while the Post-Uprate chloride values were not significantly different than the Pre-Uprate (F1,335=0.94; P=0.342). The L-31E west of CCS is not a canal that is actively managed by the SFWMD; consequently, the values observed in TPSWC-1, TPSWC-2, and TPSWC-3 on this canal are primarily driven by rainfall and runoff from the Model Lands marsh. Sites at the top also tended to be fresher compared to depth. A similar pattern was observed at TPSWC-6 which is located on the Card Sound Road canal and is viewed as a control site for the CCS stations. Differences between the top and bottom sites were greatest at TPSWC-3, which was noticeably higher at the bottom relative to the top during December 2013.

Vertical differences were also observed at TPSWID-1, TPSWID-2, and TPSWID-3 during the Post-Uprate period. The chloride concentrations varied seasonally and also with pumping of the ID. The stations were fresh for most of the year (i.e., less than 1,500 mg/L chloride), but became saline at depth with pumping and limited rainfall. Concentrations would then slowly decline with the onset of the rains in the wet season. None of the values observed Post-Uprate, however, even approached the values observed during the 2011 drought that was part of the Pre-Uprate period.

Top and bottom station differences were also observed at TPSWC-4 even though this site is only about 5 ft deep. TPSWC-4 is located along the S-20 canal southwest of the CCS. In January 2014, a weir structure was installed downstream of this site, which resulted in a reduction of flow from the canal into Biscayne Bay. This resulted in a decrease in specific conductance, chloride, and salinity in March 2014 when there would normally have been an increase due to the dry season (as observed in the Pre-Uprate period).

3.2.2.2 Ions and Silica The seasonal and spatial ion concentrations (calcium, magnesium, potassium, boron, strontium, bromide, fluoride, and sulfate) in the surface water stations followed the observations noted above for sodium and chloride. Ion concentrations in the CCS were higher than those of Biscayne Bay (Table 3.2-5), while the TPSWC and TPSWID ions were generally lower in concentration but varied seasonally with freshwater influence.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-7 Ionic concentrations in the CCS during the Post-Uprate period were generally higher than during the Pre-Uprate years, but there were no differences between the Pre-and the Post-Uprate time periods for any of the other canals or Biscayne Bay. The values in the Bay were similar in range to the values observed by Reich et al. (2006). The tri-linear diagram (Figure 3.2-4) for the average Post-Uprate period showed clear separation between the different water bodies, with TPSWC-6 and the marine/CCS stations forming the endpoints along a spectrum of ionic concentrations. TPSWC-6 was distinct from the freshwater L-31E stations (TPSWC-1, TPSWC-2, and TPSWC-3) and the ID stations, but the marine-influenced (all TPBBSW, all TPSWCCS, TPSWC-4, and TPSWC-5) and CCS stations were ionically similar. These clusters remained consistent between the Post-and Pre-Uprate time periods.

During the Post-Uprate, silica was measured only in the CCS, twice a year at six of the seven original sites (TPSWCCS-6 eliminated). Silica concentrations in the Post-Uprate showed higher values in March 2014 compared to September 2013, and the Pre-Uprate period. Silica was 5.51

+/- 0.05 mg/L (average +/- standard error) in March 2014 but approximately half the concentration in September 2013 (2.65 +/- 0.03 mg/L); these values were also higher than the average (1.63 +/-

0.41 mg/L) observed during the Pre-Uprate period. These silica values are within the range observed by the FIU Water Quality monitoring network across Florida Bay (0.000 to 5.731 mg/L) and Biscayne Bay (0.000 to 1.972 mg/L) (Boyer and Briceno 2008).

3.2.2.3 Nutrients For all statistical analyses of CCS nutrients, all data from the CCS sites where surface water sampling was discontinued (TPSWCCS-4B, -5B, -6T, and -6B) were removed from the analyses.

Figure 3.2-5 shows the distribution of nutrient concentration in the surface water for September 2013 and March 2014. The most notable change was the increase in the TN within the CCS in the Post-Uprate period compared to the Pre-Uprate period (F1,28=311.44; P<0.001). As almost all the TN in the monitoring stations was from TKN, this change was attributable to the increase of TKN in the Post-Uprate period (13.28 +/- 0.76 mg/L) compared to the Pre-Uprate period (2.01

+/- 0.05 mg/L) in the CCS (Figure 3.2-6). TKN is sum of ammonia and organic nitrogen (amino acids, urea). These increases in the CCS are from an increase in organic nitrogen sources as the ammonia contribution to the TKN of these samples were only about 1% for both sampling events. Although TKN values were approximately 15 mg/L in the CCS in September 2013, these values had decreased approximately 30% to about 11 mg/L by March 2014.

In the other water bodies, ammonia contribution varied seasonally (i.e., lower in September 2013 relative to March 2014), as well as spatially (the Bay was less than the surface water canal or the ID sites). Ammonia values in the ID and the surface water canals were higher than both the CCS or in Biscayne Bay. This is not unexpected as these canals have biological activity and limited turnover of water most of the year (Figure 3.2-6). The Post-Uprate ammonia patterns were consistent with the Pre-Uprate values (Table 3.2-5), indicating little temporal variability.

Similarly, the patterns of the other nitrogen species (i.e., nitrate/nitrite, unionized ammonia, ammonium) did not vary between the Pre-and Post-Uprate either.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-8 Total phosphorus is higher in the Post-Uprate (0.048 +/- 0.006 mg/L) compared to the Pre-Uprate (0.028 +/- 0.003 mg/L) within the CCS (F1,29=6.73; P=0.050). These differences are not unexpected given the increase in TN between the same time periods. Both TN and TP are key biological nutrients so an increase in TN is often accompanied by an increase in TP (Quiros 2002). Values in the other water bodies however remained consistent and did not show a similar Pre-Post Uprate increase over the monitoring duration.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 TABLES

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-10 Table 3.0-1. Groundwater and Surface Water Sampling Locations and Events Event Locations Source Category1 Quarterly TPGW-1, -2, -3, -4, -5, -6, -7, -8, -9, -10, -

11, -12, -13, -14; L-3, -5; G-21, -28, -35 GW TPBBSW - 1, 2, 3, 4, 5 TPSWC - 1, 2, 3, 4, 5, 6 TPSWID - 1, 2, 3 SW TPSWCCS - 1, 2, 3, 4, 5, 6, 7 CCS Semi-annual TPGW-3, 4, 5, 6, 7, 8, 9, 11, 13, L-3, L-5, G-21, G-28, G-35 GW TPGW - 1, 2, 10, 13, 14 GW - quarterly analytes plus nutrients TPBBSW - 1, 2, 3, 4, 5 TPSWC - 1, 2, 3, 4, 5, 6 TPSWID - 1, 2, 3 SW - quarterly analytes plus nutrients TPSWCCS - 1, 2, 3, 4, 5, 6, 7 CCS - quarterly analytes plus nutrients Notes:

1 = Analytes from Table 3.0-2 plus field parameters (temperature, specific conductivity, DO, percent oxygen saturation, pH, ORP, and salinity) at all stations.

Key:

CCS - Cooling Canal System.

GW - Groundwater.

ORP = Oxidation reduction potential.

SW - Surface Water.

TPBBSW - Biscayne Bay Surface Water.

TPGW - Turkey Point Groundwater.

TPSWC - Turkey Point Surface Water Canal.

TPSWID - Turkey Point Surface Water Interceptor Ditch.

TPSWCCS - Turkey Point Surface Water Cooling Canal System.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-11 Table 3.0-2.

Analytes Measured in Groundwater, Surface Water, and the Cooling Canal System Analyte Monitoring Plan (Table 2-1) Label GW SW CCS Chloride (Cl-)

Ions Q

Q Q

Sodium (Na+)

Q Q

Q Other Anions (SO4 2-, F-, Br-)

Ions SA SA SA Other Cations (Ca2+, Mg2+, K+, Sr2+, B+)

Ions SA SA SA Alkalinity Ions SA SA SA Ammonia + unionized Nutrients SA SA SA Nitrate/Nitrite Nutrients SA SA SA Total Kjeldahl Nitrogen Nutrients SA SA SA Total Phosphorus Nutrients SA SA SA Soluble Reactive Phosphorus Nutrients SA SA SA Silica Nutrients SA Sulfides Ions SA SA SA TDS Other Q

Key:

Q = Quarterly event.

SA = Semi-annual event.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-12 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 25.75 25.76 25.88 26.22 26.78 26.74 26.08 26.19 25.97 25.4 25.37 25.23 24.11 24.13 24.11 pH SU 6.97 7.07 6.91 7.2 6.84 6.94 6.49 6.83 6.74 6.87 7.02 6.86 7.01 6.79 6.95 Dissolved Oxygen mg/L 0.21 0.36 0.43 0.23 J

0.28 J

0.56 J

0.88 0.36 1.09 0.6 0.64 0.74 0.39 0.73 1.19 Specific Conductance S/cm 54661 72371 72253 69081 75789 77111 64740 69067 69917 J

1670 39169 43372 1134 32517 34844 Turbidity NTU 0.35 0.01 0.1 0.69 0.13 0.08 0.04 0.32 0.3 0.39 0.14 0.16 0.1 0.19 0.22 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 10900 15200 15300 16800 18900 18600 13400 14500 14700 178 7540 8800 100 6340 6650 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 20500 29800 29900 27700 30900 30000 27300 29300 33000 J

342 13800 16400 204 12100 12700 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N 0.783 0.585 0.497 0.19 J

0.562 0.558 Ammonium ion (NH4

+)

mg/L 1.00 0.748 0.636 0.243 0.72 0.714 Unionized NH3 mg/L 0.004 0.004 0.003 0.001 0.002 0.003 Nitrate/Nitrite mg/L as N 0.005 U

0.005 U

0.005 U

0.005 U

0.005 U

0.005 U

TKN mg/L 1.28 1.13 0.903 0.519 0.829 0.843 TN mg/L 1.29 1.14 0.908 0.524 0.834 0.848 ortho-Phosphate mg/L 0.061 J

0.035 J

0.033 J

0.038 0.042 J

0.039 J

Total Phosphorus (P) mg/L 0.002 UJ 0.021 J

0.027 J

0.004 I

0.02 J

0.012 J

Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 34300 50000 48300 43300 47400 49300 42500 45300 47500 850 21300 25900 613 20800 20800 Salinity 36.17 49.78 49.68 47.6 52.47 53.53 43.8 47.17 47.84 J

0.84 J

24.93 27.92 0.56 J

20.37 21.92 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/4/2013 6/7/2013 6/11/2013 6/11/2013 6/11/2013 6/7/2013 6/6/2013 6/6/2013 6/6/2013 6/6/2013 6/7/2013 6/4/2013 6/4/2013 6/6/2013 6/6/2013 TPGW-1M TPGW-1D TPGW-4D TPGW-4M TPGW-4S TPGW-2D TPGW-2M TPGW-5D TPGW-3D TPGW-1S TPGW-5M TPGW-5S TPGW-2S TPGW-3M TPGW-3S

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-13 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 23.84 24.04 24.35 24.26 24.44 24.43 24.36 24.1 24.26 25.04 24.47 24.39 pH SU 6.94 7.02 6.83 6.99 6.96 7.04 11.66 6.99 6.88 6.75 6.71 6.89 Dissolved Oxygen mg/L 1.13 0.85 0.23 0.2 0.5 0.32 0.74 0.81 0.25 0.28 0.74 1.2 Specific Conductance S/cm 1107 22767 23691 546 559 599 1178 642 677 605 625 642 Turbidity NTU 0.98 0.01 1.42 0.95 0.09 0.31 0.35 0.02 0.7 0.12 0.22 0.24 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 88.7 4130 4090 4280 19 19.8 25.6 19.1 18 25.3 10.9 11.8 15.5 15.3 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 178 7830 8050 8270 34.8 34.1 43.2 34.9 43.8 44.6 19.5 20 27.1 25.2 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N 0.313 0.508 0.525 0.584 0.103 0.129 0.087 0.179 0.139 0.141 0.353 0.305 0.368 0.398 Ammonium ion (NH4

+)

mg/L 0.401 0.65 0.748 0.132 0.165 0.111 0.03 U

0.178 0.181 0.452 0.391 0.471 Unionized NH3 mg/L 0.002 0.003 0.003 7E-04 8E-04 6E-04 0.216 9E-04 7E-04 0.001 0.001 0.002 Nitrate/Nitrite mg/L as N 0.005 U

0.005 U

0.0054 U

0.005 U

0.01 0.006 I

0.014 0.007 I

0.005 U

0.016 0.009 I

0.014 0.024 0.0054 U

TKN mg/L 0.849 0.523 J

0.767 J

0.712 0.973 1.24 3.43 11.8 0.326 0.471 0.81 0.678 0.793 0.754 TN mg/L 0.854 0.528 0.717 0.983 1.25 3.44 11.8 0.331 0.487 0.819 0.692 0.817 ortho-Phosphate mg/L 0.054 J

0.037 J

0.0365 0.038 J

0.001 U

0.002 I

0.002 I

0.001 U

0.001 I

0.002 I

0.007 I

0.005 I

0.001 U

0.0014 U

Total Phosphorus (P) mg/L 0.003 IJ 0.013 J

0.0126 0.013 J

0.006 I

0.007 I

0.007 I

0.004 U

0.01 I

0.011 I

0.013 I

0.038 0.014 I

0.0022 U

Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 540 12800 13700 13900 264 296 304 280 J

332 352 300 332 332 340 Salinity 0.55 J

13.74 14.35 0.26 J

0.27 J

0.29 J

0.58 J

0.31 J

0.33 J

0.29 J

0.3 J

0.31 J

Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/6/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/6/2013 6/6/2013 6/6/2013 6/5/2013 TPGW-9M TPGW-9S TPGW-7S TPGW-8D TPGW-8M TPGW-8S TPGW-9D TPGW-6S 060513-DUP1 TPGW-7D TPGW-7M TPGW-6D TPGW-6M 6/5/2013 060613-DUP1

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-14 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 26.58 26.61 26.29 25.94 26.08 26.27 26.21 26.33 26.19 29.57 29.19 29.44 pH SU 7.53 7.48 6.69 6.79 6.58 6.74 6.51 6.81 7.14 6.73 6.84 6.86 Dissolved Oxygen mg/L 0.3 0.25 0.34 0.08 0.05 0.2 0.67 0.44 0.16 0.33 0.24 0.66 Specific Conductance S/cm 52399 55198 65776 54830 56758 61576 45468 63156 65782 83609 79528 80552 Turbidity NTU 0.27 0.23 0.29 0.4 0.44 0.41 0.4 0.3 0.38 0.11 0.12 0.26 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 10700 11600 13700 11400 11800 12900 8970 12800 13300 18100 17000 17100 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 23200 23800 29000 24300 23000 25700 16800 24700 25100 39800 37200 36600 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 37000 37300 43500 36100 37200 41900 27100 41600 43300 58500 55600 55400 Salinity 34.47 36.55 44.6 36.29 37.74 41.38 29.41 42.58 44.61 58.69 55.38 56.21 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/11/2013 6/11/2013 6/11/2013 TPGW-13D 6/13/2013 6/13/2013 6/13/2013 6/4/2013 TPGW-12S TPGW-12D 6/4/2013 TPGW-12M 6/4/2013 TPGW-11M TPGW-11S TPGW-10M TPGW-10S TPGW-13M TPGW-11D TPGW-10D TPGW-13S 6/12/2013 6/12/2013 6/12/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-15 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units RER Temperature

°C N26.77 27.18 27.3 pH SU N 6.73 6.78 6.68 Dissolved Oxygen mg/L N 0.13 0.2 0.27 Specific Conductance S/cm N57630 63204 73522 Turbidity NTU N 0.04 0.4 0.06 Silica, dissolved mg/L N

Calcium mg/L N

Magnesium mg/L N

Potassium mg/L N

Sodium mg/L N11900 12500 13100 15900 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L N

Strontium mg/L N

Bromide mg/L N

Chloride mg/L N24400 24600 27700 32900 0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

Fluoride mg/L 1

Sulfate mg/L N

Total Ammonia mg/L as N 0.026 U

0.0309 I

Ammonium ion (NH4

+)

mg/L N

Unionized NH3 mg/L N

Nitrate/Nitrite mg/L as N N

0.0054 U

0.0054 U

TKN mg/L N

0.236 0.15 U

TN mg/L N

ortho-Phosphate mg/L N

0.0014 U

0.0014 U

Total Phosphorus (P) mg/L N

0.0022 U

0.0022 U

Alkalinity mg/L N

Bicarbonate Alkalinity mg/L as CaCO3 N Sulfide mg/L Total Dissolved Solids mg/L N38900 38000 43200 51600 5

U 5

U 5

U 5

U 5

U Salinity 38.37 42.59 50.64 Tritium pCi/L N

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/10/2013 061113-EB1 6/6/2013 6/5/2013 6/11/2013 060413-FB1 060513-FB1 TPGW-14D TPGW-14M TPGW-14S 061213-DUP1 061213-FB1 6/4/2013 060613-FB1 061013-FB1 6/12/2013 6/12/2013 6/12/2013 6/12/2013 6/12/2013 060713-FB1 061313-FB1 6/7/2013 6/13/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-16 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 26.77 27.18 27.3 pH SU 6.73 6.78 6.68 Dissolved Oxygen mg/L 0.13 0.2 0.27 Specific Conductance S/cm 57630 63204 73522 Turbidity NTU 0.04 0.4 0.06 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 11900 12500 13100 15900 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 24400 24600 27700 32900 0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N 0.026 U

0.0309 I

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.0054 U

0.0054 U

TKN mg/L 0.236 0.15 U

TN mg/L ortho-Phosphate mg/L 0.0014 U

0.0014 U

Total Phosphorus (P) mg/L 0.0022 U

0.0022 U

Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 38900 38000 43200 51600 5

U 5

U 5

U 5

U 5

U Salinity 38.37 42.59 50.64 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/10/2013 061113-EB1 6/6/2013 6/5/2013 6/11/2013 060413-FB1 060513-FB1 TPGW-14D TPGW-14M TPGW-14S 061213-DUP1 061213-FB1 6/4/2013 060613-FB1 061013-FB1 6/12/2013 6/12/2013 6/12/2013 6/12/2013 6/12/2013 060713-FB1 061313-FB1 6/7/2013 6/13/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-17 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 26.68 26.74 27.10 26.08 26.48 26.77 26.70 26.61 26.79 pH SU 6.99 6.94 6.99 7.12 6.89 6.74 6.63 6.90 6.77 Dissolved Oxygen mg/L 0.33 0.40 1.07 0.10 0.09 0.95 J

0.20 0.19 1.93 J

Specific Conductance S/cm 34093 72181 70477 66453 75066 77475 63967 67890 70817 Turbidity NTU 0.45 0.29 0.24 0.79 0.11 0.09 0.07 0.11 0.28 Silica, dissolved mg/L Calcium mg/L 411 644 653 1080 J

669 J

667 673 653 624 639 Magnesium mg/L 726 1610 J-1650 J-1210 J

1680 J

1690 1730 1460 1550 1590 Potassium mg/L 241 592 J+

614 J+

527 J

614 J

613 628 509 558 569 Sodium mg/L 6290 14700 14300 13900 J

15900 J

15800 16200 13300 14300 14300 Boron mg/L 2.29 5.83 5.81 5.24 6.33 6.35 6.46 5.05 5.7 5.83 Strontium mg/L 6.09 10.8 11.1 13.2 13.5 13.6 13.4 10.8 11.8 11.9 Bromide mg/L 45.2 J

92.5 101 J

94.8 J

107 J

108 111 J

91.8 96.5 98.3 Chloride mg/L 13500 J

28800 31300 J

28100 J

31800 J

32000 33500 J

27100 28800 29400 Fluoride mg/L 0.198 J

0.233 J-0.251 J-0.173 J

0.231 J

0.234 J

0.221 J

0.0240 U

0.182 J

0.183 J

Sulfate mg/L 1570 J

3660 3880 J

3340 J

3900 J

3910 4050 J

3400 3550 3650 Total Ammonia mg/L as N 0.948 1.60 1.55 1.57 1.93 1.86 1.85 Ammonium ion (NH4

+)

mg/L 1.21 2.05 1.98 2.00 2.47 2.37 Unionized NH3 mg/L 0.00716 0.0108 0.0121 0.0153 0.0114 0.00793 Nitrate/Nitrite mg/L as N 0.0270 U

0.0280 I

0.0270 U

0.0270 U

0.0299 0.0227 0.0270 U

TKN mg/L 1.73 J

2.65 J

2.75 J

2.62 2.64 2.61 3.16 TN mg/L 1.76 J

2.68 J

2.78 J

2.65 2.67 2.63 3.19 ortho-Phosphate mg/L 0.0222 0.00340 I

0.0447 J

0.0104 0.0358 J

0.0356 0.0343 J

Total Phosphorus (P) mg/L 0.0282 0.0346 0.0346 J

0.0131 0.0204 J

0.0218 0.0169 J

Alkalinity mg/L 291 J

183 183 J

103 J

194 J

194 193 J

406 234 224 Bicarbonate Alkalinity mg/L as CaCO3 291 J

183 183 J

103 J

194 J

194 193 J

406 234 224 Sulfide mg/L 1.46 1.00 U

1.38 1.24 1.01 1.09 1.01 11.0 1.17 1.63 Total Dissolved Solids mg/L 20900 49800 49000 43200 53600 51400 51800 41100 44700 45200 Dissolved Inorganic Carbon mg/L Salinity 21.35 49.6 48.24 45.13 51.9 53.82 43.2 46.23 48.51 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 090413-DUP1 is a duplicate of TPGW-8M.

Sample 091113-DUP1 is a duplicate of TPGW-2M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

091113-DUP 09/06/2013 09/06/2013 09/06/2013 09/11/2013 09/11/2013 09/11/2013 09/11/2013 09/11/2013 09/11/2013 09/11/2013 TPGW-1D TPGW-1M TPGW-3S TPGW-3D TPGW-3M TPGW-2D TPGW-2M TPGW-2S TPGW-1S

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-18 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 25.60 25.22 25.32 25.17 24.92 25.04 24.44 24.35 24.71 24.61 24.49 24.56 pH SU 6.65 6.94 7.16 6.64 6.99 6.75 6.87 6.69 6.95 6.96 6.90 Dissolved Oxygen mg/L 0.47 1.26 J

0.84 0.75 J

1.20 0.93 J

0.46 0.33 J

0.30 0.28 0.20 1.05 Specific Conductance S/cm 1815 39421 43517 1028 33043 35014 1182 22893 23830 539 553 738 Turbidity NTU 0.30 0.53 0.39 0.47 0.40 0.34 0.10 0.53 0.10 1.99 0.00 J

0.44 Silica, dissolved mg/L Calcium mg/L 139 591 J-584 J-109 609 J-580 J-119 497 J-507 J-79.0 82.6 95.1 Magnesium mg/L 18.6 784 890 7.08 646 664 11.5 403 419 3.87 3.91 4.41 Potassium mg/L 4.04 200 269 5.74 150 173 4.69 102 106 7.49 7.19 5.27 Sodium mg/L 189 7080 J-8130 80.6 5910 J-6170 J-99.5 3790 J-3970 J-18.4 19.7 38.4 Boron mg/L 0.0667 1.42 2.11 0.0497 I

1.02 1.25 0.0605 0.789 0.813 0.0446 I

0.0489 I

0.0602 Strontium mg/L 1.3 7.44 7.84 1.08 7.08 7.21 1.2 7.75 7.88 0.785 0.818 0.934 Bromide mg/L 1.30 46.6 55.1 0.584 37.9 44.1 0.727 26.5 27.7 0.147 0.152 0.348 Chloride mg/L 400 15500 17600 170 13100 13700 208 8120 8980 35.0 36.4 90.8 Fluoride mg/L 0.0900 I

0.125 0.131 0.112 0.119 0.128 0.120 0.133 0.133 0.118 0.114 0.112 Sulfate mg/L 9.40 1690 1990 16.9 1340 1480 8.87 825 872 22.1 23.7 25.7 Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L 332 212 203 244 228 222 282 210 217 199 203 201 Bicarbonate Alkalinity mg/L as CaCO3 332 212 203 244 228 222 282 210 217 199 203 201 Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.30 1.00 U

1.77 1.38 1.06 1.22 Total Dissolved Solids mg/L 900 24000 27300 507 19900 20500 607 13900 14000 276 284 408 Dissolved Inorganic Carbon mg/L Salinity 0.9 J

25.1 28.0 0.51 J

20.7 22.0 0.59 J

13.82 14.43 0.26 J

0.27 J

0.36 J

Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 090413-DUP1 is a duplicate of TPGW-8M.

Sample 091113-DUP1 is a duplicate of TPGW-2M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

09/03/2013 09/03/2013 09/04/2013 09/04/2013 09/04/2013 09/03/2013 09/03/2013 TPGW-7M TPGW-7S 09/03/2013 TPGW-4S TPGW-6D TPGW-6M TPGW-6S TPGW-5M TPGW-5S TPGW-7D 09/03/2013 TPGW-5D 09/03/2013 09/03/2013 TPGW-4M TPGW-4D 09/03/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-19 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 24.84 25.01 25.25 26.10 25.78 25.65 27.48 27.46 27.23 pH SU 10.77 J

6.78 6.78 6.66 6.68 6.65 7.31 7.32 6.97 Dissolved Oxygen mg/L 1.48 0.56 0.18 0.50 0.45 0.39 0.25 0.12 0.62 J

Specific Conductance S/cm 1139 J

642 681 594 639 644 51928 54309 66489 Turbidity NTU 0.23 0.10 0.96 2.31 0.54 0.09 0.17 0.08 0.14 Silica, dissolved mg/L Calcium mg/L 102 102 102 101 114 117 111 506 506 649 Magnesium mg/L 0.564 3.74 3.69 5.93 2.51 3.15 3.61 1400 J-1390 J-1740 J-Potassium mg/L 9.55 9.94 9.71 8.92 4.20 6.64 3.87 486 503 626 Sodium mg/L 18.3 17.3 17.0 26.6 8.05 12.3 15.2 12000 J-11900 J-15200 J-Boron mg/L 0.043 I

0.065 0.064 0.0786 0.0346 I

0.0492 I

0.0528 5.12 5.27 6.32 Strontium mg/L 0.576 1.03 1.01 1.05 0.811 0.968 1.14 8.83 9.43 11.8 Bromide mg/L 0.211 0.215 0.216 0.251 0.151 0.248 0.369 71.6 75.4 91.7 Chloride mg/L 34.0 32.6 32.9 45.6 15.8 22.5 28.0 21100 22400 26900 Fluoride mg/L 0.0813 I

0.0947 I

0.0939 I

0.103 0.0885 I

0.0870 I

0.0908 I

0.748 J-0.585 J-0.250 J-Sulfate mg/L 46.7 58.7 58.5 53.9 3.09 18.1 29.7 2760 2880 3400 Total Ammonia mg/L as N 0.413 0.298 0.796 Ammonium ion (NH4

+)

mg/L 0.524 0.378 1.02 Unionized NH3 mg/L 0.00684 0.00504 0.00597 Nitrate/Nitrite mg/L as N 0.128 0.00540 U

0.00998 I

TKN mg/L 0.741 J

0.762 J

1.17 J

TN mg/L 0.87 J

0.77 J

1.18 J

ortho-Phosphate mg/L 0.0222 J

0.0206 J

0.0400 J

Total Phosphorus (P) mg/L 0.00907 I J 0.00601 I J 0.0135 J

Alkalinity mg/L 182 226 223 227 286 284 266 130 117 157 Bicarbonate Alkalinity mg/L as CaCO3 1.00 U

226 223 227 286 284 266 130 117 157 Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.26 1.00 U

1.00 U

5.06 1.51 3.75 Total Dissolved Solids mg/L 307 J

356 344 368 308 332 348 38100 41300 46900 Dissolved Inorganic Carbon mg/L Salinity 0.56 J

0.31 J

0.33 J

0.29 J

0.31 J

0.31 J

34.07 35.86 45.13 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

09/12/2013 09/12/2013 09/12/2013 09/04/2013 09/04/2013 09/04/2013 09/04/2013 09/04/2013 09/04/2013 09/04/2013 TPGW-8D TPGW-8M TPGW-8S 090413-DUP TPGW-10S TPGW-9D TPGW-9M TPGW-9S TPGW-10D TPGW-10M

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-20 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 27.19 27.24 26.71 27.05 27.38 27.43 29.53 29.27 29.58 27.36 27.37 27.40 pH SU 6.96 6.60 6.82 6.57 6.81 7.20 6.77 6.85 6.84 6.92 6.83 6.70 Dissolved Oxygen mg/L 0.46 0.75 J

0.61 0.11 0.13 0.26 0.02 0.32 0.13 0.19 0.03 1.10 J

Specific Conductance S/cm 54061 58157 59926 43559 65648 64449 83887 78994 80613 57102 61790 75201 Turbidity NTU 0.16 0.00 J

0.26 0.54 0.41 1.19 1.07 0.05 0.03 0.06 0.50 0.21 Silica, dissolved mg/L Calcium mg/L 545 596 622 501 616 605 758 J

693 722 547 662 671 Magnesium mg/L 1360 J-1390 J-1470 J-968 1480 J-1430 J-2010 J-1720 J-1850 J-1370 J-1590 J-1790 J-Potassium mg/L 500 498 526 330 526 J+

523 J+

753 J+

702 J+

683 J+

484 601 652 Sodium mg/L 11900 J-12500 J-13200 J-8310 12600 13000 17700 J

16500 16500 12100 J-14500 J-15500 J-Boron mg/L 5.5 5.44 5.38 3.36 4.95 4.98 7.55 6.89 6.98 5.09 6.15 6.57 Strontium mg/L 9.33 9.84 10.7 6.89 9.89 9.85 13.9 14.2 13.4 9.34 11.9 13.1 Bromide mg/L 75.5 78.1 84.7 55.7 85.0 89.9 122 J

113 J

116 J

79.0 84.7 108 J

Chloride mg/L 22300 23300 25400 17600 28300 27800 37300 J

34700 J

36400 J

23500 25100 32900 J

Fluoride mg/L 0.780 J-0.531 J-0.600 J-0.395 0.243 J-0.239 J-0.354 J-0.193 J-0.212 J-0.484 J-0.409 J-0.377 V J-Sulfate mg/L 2890 2920 3140 2170 3550 3500 4820 J

4120 J

4580 J

2980 3160 3900 J

Total Ammonia mg/L as N 2.59 1.45 J+

1.73 0.479 0.972 2.08 Ammonium ion (NH4

+)

mg/L 3.31 1.85 J+

2.21 0.612 1.24 2.67 Unionized NH3 mg/L 0.0144 0.00950 J+

0.0113 0.00323 0.00534 0.00850 Nitrate/Nitrite mg/L as N 0.0402 I

0.0892 0.0482 I

0.00645 I

0.00967 I

0.00917 I

TKN mg/L 4.27 3.04 J+

3.00 1.31 J

1.53 J

3.00 J

TN mg/L 4.31 3.13 J+

3.05 1.32 J

1.54 J

3.01 J

ortho-Phosphate mg/L 0.0500 J

0.00163 I

0.0122 0.0505 J

0.077 J

0.0612 J

Total Phosphorus (P) mg/L 0.0382 J

0.0378 0.0294 0.0332 J

0.0545 J

0.024 J

Alkalinity mg/L 288 333 280 562 210 193 187 J

190 J

183 J

254 278 219 J

Bicarbonate Alkalinity mg/L as CaCO3 288 333 280 562 210 193 187 J

190 J

183 J

254 278 219 J

Sulfide mg/L 13.3 10.3 12.9 17.2 1.89 1.00 U

9.45 1.00 U

1.00 U

9.71 10.2 6.14 Total Dissolved Solids mg/L 37500 40400 43200 27300 45600 45000 59900 54000 56000 41500 43100 52000 Dissolved Inorganic Carbon mg/L Salinity 35.68 38.75 40.11 28.01 44.47 43.54 58.93 54.95 56.25 37.85 41.5 51.98 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

09/12/2013 09/12/2013 09/12/2013 09/12/2013 09/12/2013 09/12/2013 09/06/2013 09/06/2013 09/06/2013 09/06/2013 09/06/2013 09/06/2013 TPGW-12S TPGW-11M TPGW-11S TPGW-14M TPGW-14S TPGW-14D TPGW-12D TPGW-13S TPGW-11D TPGW-13D TPGW-13M TPGW-12M

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-21 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C pH SU Dissolved Oxygen mg/L Specific Conductance S/cm Turbidity NTU Silica, dissolved mg/L 0.0500 U

Calcium mg/L 0.100 U

0.100 U

0.100 U

0.100 U

0.100 U

Magnesium mg/L 0.0200 U

0.0200 U

0.0267 I

0.0200 U

0.0200 U

Potassium mg/L 0.190 U

0.190 U

0.190 U

0.190 U

0.190 U

Sodium mg/L 0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

Boron mg/L 0.01 U

0.01 U

0.01 U

0.01 U

0.01 U

Strontium mg/L 0.001 U

0.001 U

0.001 U

0.001 U

0.001 U

Bromide mg/L 0.0130 U

0.0130 U

0.0130 U

0.0130 U

0.0130 U

Chloride mg/L 0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

Fluoride mg/L 0.0240 U

0.0240 U

0.0240 U

0.179 0.0240 U

Sulfate mg/L 0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

Total Ammonia mg/L as N 0.0314 I

0.0262 I

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.0270 U

0.00540 U

TKN mg/L 0.294 0.311 TN mg/L ortho-Phosphate mg/L 0.00140 U

0.00140 U

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U

Alkalinity mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Bicarbonate Alkalinity mg/L as CaCO3 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 5.00 U

5.00 U

5.00 U

5.00 U

Dissolved Inorganic Carbon mg/L Salinity Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

090613-EB1 091213-FB1 09/12/2013 09/11/2013 09/03/2013 09/06/2013 091113-FB1 09/04/2013 090413-FB1 090313-FB1

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-22 Table 3.1-3. Summary of Groundwater Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 26.27 26.32 26.39 25.88 26.22 26.52 25.78 25.73 25.83 25.56 25.39 25.13 24.17 24.15 24.00 23.94 24.10 24.16 pH SU 6.92 6.99 6.93 7.01 6.86 6.83 6.55 6.81 6.79 6.80 6.80 6.88 7.08 6.79 6.81 7.04 6.85 6.85 Dissolved Oxygen mg/L 0.17 0.23 0.15 0.21 0.20 0.25 0.45 0.13 0.35 0.24 0.27 0.22 0.57 0.47 0.37 0.35 0.37 1.54 Specific Conductance S/cm 40990 71492 71410 68018 74691 75916 63968 67946 69433 2057 38730 43259 1120 32585 34738 1185 22688 23614 Turbidity NTU 0.18 0.08 0.02 0.35 0.01 J

0.14 0.06 0.00 J

0.15 0.01 J

0.79 0.01 J

0.04 0.01 J

0.00 J

0.24 0.03 0.22 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 7980 15300 15100 14400 15900 16300 13400 13900 14800 228 7330 8400 98.5 6040 6430 103 3950 4050 4220 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 13500 29400 29400 27300 30500 30300 25200 27400 28600 460 15100 16300 202 11900 12500 223 7980 8350 8930 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 26000 48700 47700 46600 53400 54800 43300 46300 47700 1020 22900 26900 613 19900 19900 600 13800 13500 13800 Salinity 26.2 49.1 49.0 46.4 51.6 52.6 43.2 46.3 47.5 1.1 J

24.6 27.8 0.6 J

20.4 21.9 0.6 J

13.7 14.3 Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120213-DUP is a duplicate of TPGW-13S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

12/02/2013 12/02/2013 12/03/2013 12/04/2013 12/03/2013 12/03/2013 12/04/2013 12/04/2013 12/02/2013 12/05/2013 12/04/2013 12/04/2013 TPGW-3S TPGW-3M 12/04/2013 TPGW-3D 12/04/2013 12/04/2013 TPGW-2M 12/05/2013 TPGW-2D 12/05/2013 TPGW-5D TPGW-1S TPGW-4S TPGW-4M TPGW-4D TPGW-1M TPGW-1D TPGW-5M TPGW-5S 120413-DUP TPGW-6M TPGW-6D TPGW-6S 12/04/2013 TPGW-2S 12/04/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-23 Table 3.1-3. Summary of Groundwater Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 24.25 24.09 24.21 24.52 25.24 24.17 25.16 24.16 24.37 26.59 26.52 26.09 26.07 25.88 25.76 25.96 26.04 26.23 pH SU 7.19 7.14 6.90 11.41 6.93 7.06 6.80 6.92 6.83 7.15 7.16 6.99 6.82 6.62 6.73 6.54 6.77 7.10 Dissolved Oxygen mg/L 0.27 0.24 0.27 0.34 0.29 0.29 0.57 0.24 0.61 0.39 0.25 0.35 0.30 0.55 0.69 0.75 0.15 0.31 Specific Conductance S/cm 535 558 1056 1412 632 669 595 621 638 52766 55326 65884 55215 57021 61193 43162 61327 64659 Turbidity NTU 0.01 J

0.06 0.25 0.82 0.09 0.44 0.67 0.21 0.12 0.08 0.00 J

0.00 J

0.00 J

0.35 0.17 0.21 0.20 0.49 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 18.8 20.2 59.4 18.2 16.7 25.1 8.77 12.7 15.5 10900 11500 14300 11500 12000 12800 8180 12900 13700 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 34.0 35.0 180 32.4 30.8 42.2 16.4 22.4 27.1 20900 25600 26600 23000 23000 23400 16400 24100 26200 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 236 268 620 300 308 376 292 324 312 34500 35300 43500 35100 38500 41400 27100 40000 43100 Salinity 0.3 J

0.3 J

0.5 J

0.7 J

0.3 J

0.3 J

0.3 J

0.3 J

0.3 J

34.7 36.7 44.7 36.6 37.9 41.1 27.8 41.2 43.7 Tritium pCi/L NOTES:

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

Text in blue is revised.

  • PSS-78 salinity is unitless.
  • PSS-78 salinity is unitless.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120213-DUP is a duplicate of TPGW-13S.

Sample 120213-DUP is a duplicate of TPGW-13S.

KEY:

KEY:

°C = Degrees Celsius.

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL. I = Value between the MDL and PQL.

12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 TPGW-9S TPGW-12D 12/11/2013 TPGW-8D TPGW-12S TPGW-9M TPGW-10D 12/11/2013 TPGW-7S TPGW-7M TPGW-7D TPGW-9D TPGW-8M TPGW-12M TPGW-10S TPGW-8S 12/05/2013 12/05/2013 12/05/2013 TPGW-10M TPGW-11D TPGW-11M TPGW-11S 12/11/2013 12/11/2013 12/11/2013 12/11/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-24 Table 3.1-3. Summary of Groundwater Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 28.75 28.80 29.01 26.36 26.44 26.18 pH SU 6.84 6.85 6.92 6.79 6.70 6.73 Dissolved Oxygen mg/L 0.19 0.10 1.10 0.36 0.34 0.39 Specific Conductance S/cm 82973 78333 80246 57523 62249 74211 Turbidity NTU 0.01 J

0.01 J

0.06 0.00 J

0.16 0.87 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 17200 17400 16500 16800 12000 12800 15900 0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 35100 41800 33000 33200 22500 25500 27900 0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

0.313 I

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 58900 58800 54700 55900 37100 39300 50200 5.00 U

5.00 U

5.00 U

5.00 U

5.00 U

64.0 Salinity 58.2 54.4 56.0 38.3 41.9 51.2 Tritium pCi/L NOTES:

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

Text in blue is revised.

  • PSS-78 salinity is unitless.
  • PSS-78 salinity is unitless.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120213-DUP is a duplicate of TPGW-13S.

Sample 120213-DUP is a duplicate of TPGW-13S.

KEY:

KEY:

°C = Degrees Celsius.

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL. I = Value between the MDL and PQL.

12/03/2013 12/02/2013 12/02/2013 12/04/2013 120413-FB1 120313-FB1 12/11/2013 12/11/2013 12/11/2013 12/02/2013 12/02/2013 12/02/2013 120213-EB1 TPGW-13D TPGW-13S 120213-DUP 120613-FB1 TPGW-13M 121113-FB1 12/05/2013 12/06/2013 12/11/2013 TPGW-14D TPGW-14M TPGW-14S 120513-FB1

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-25 Table 3.1-4. Summary of Groundwater Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 26.07 25.89 26.35 25.73 25.65 25.99 26.08 25.71 26.18 25.32 25.05 25.20 pH SU 7.02 7.07 6.87 7.06 6.91 6.66 6.57 6.90 6.81 6.87 6.89 6.81 Dissolved Oxygen mg/L 0.33 0.28 0.63 0.14 0.19 0.19 0.16 0.12 0.28 0.44 0.30 0.66 Specific Conductance S/cm 41613 70203 71364 68244 J

74618 76333 63180 67828 69489 2485 38121 42719 Turbidity NTU 0.27 0.34 0.23 0.11 0.10 0.09 0.06 0.07 0.02 0.15 0.02 0.00 J

Calcium mg/L 454 634 637 691 692 675 700 675 632 J

646 166 579 558 Magnesium mg/L 909 1660 1630 1510 1760 1690 1810 1480 1540 J

1560 28.1 835 944 Potassium mg/L 300 602 600 554 621 611 653 516 556 J

574 5.19 201 258 Sodium mg/L 8190 15300 J

15400 J+

14200 15900 15800 16200 13200 14300 J

15200 J

291 7530 8700 Boron mg/L 3.03 6.06 5.99 5.96 6.51 6.48 6.85 5.02 5.78 5.90 0.08 1.52 2.11 Strontium mg/L 7.83 12.00 12.10 13.10 14.30 14.00 14.40 11.10 12.00 12.30 1.55 7.91 8.12 Bromide mg/L 52.1 97.4 98.6 92.5 J

104.0 102.0 106.0 84.3 92.2 J

95.3 2.2 49.7 53.5 Chloride mg/L 14700 27300 27500 27600 J

30700 30700 31000 25400 27500 J

26500 609 14000 15600 Fluoride mg/L 0.223 0.259 J

0.281 J-0.224 J

0.269 J

0.270 0.243 J

0.206 J

0.194 J

0.201 J-0.099 I

0.128 0.135 Sulfate mg/L 2000 3960 3800 3830 J

4130 4380 4370 3950 4380 J

3700 27 1780 2100 Total Ammonia mg/L as N 1.290 1.240 J

1.620 J-1.490 1.940 1.920 1.240 Ammonium ion (NH4

+)

mg/L 1.65 1.58 J

2.07 J-1.90 2.48 1.59 Unionized NH3 mg/L 0.01000 0.01060 J

0.00908 J-0.01240 0.01140 0.00419 Nitrate/Nitrite mg/L as N 0.0270 U

0.0270 U

0.0270 U

0.0337 I

0.0336 I

0.0316 I

0.0318 I

TKN mg/L 1.83 2.23 2.20 2.06 2.88 2.75 2.78 TN mg/L 1.86 2.26 2.23 2.09 2.91 2.78 2.81 ortho-Phosphate mg/L 0.0101 J

0.0101 J

0.0460 0.0177 J

0.0425 J

0.0417 0.0449 Total Phosphorus (P) mg/L 0.0039 IJ 0.0022 UJ 0.0570 0.0022 UJ 0.0290 J

0.0313 0.0439 Alkalinity mg/L 269 182 180 185 J

202 203 197 484 241 J

223 322 211 203 Bicarbonate Alkalinity mg/L as CaCO3 269 182 180 185 J

202 203 197 484 241 J

223 322 211 203 Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U Q 1.00 U Q 1.00 U Q 1.00 U

22.00 Q

1.00 U Q 1.00 U Q 1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 25300 48800 48700 47800 53100 52700 55200 42000 47000 47700 1390 23100 26900 Salinity 26.63 48.06 48.96 46.53 J

51.56 52.93 42.61 46.22 47.5 1.27 J

24.19 27.45 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030414-DUP1 is a duplicate of TPGW-2M.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

030414-DUP 03/11/2014 03/11/2014 03/11/2014 03/04/2014 03/04/2014 03/04/2014 03/04/2014 03/04/2014 03/04/2014 03/04/2014 TPGW-1D TPGW-1M TPGW-4S 03/10/2014 03/10/2014 TPGW-4M TPGW-4D 03/10/2014 TPGW-3S TPGW-3D TPGW-3M TPGW-2D TPGW-2M TPGW-2S TPGW-1S

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-26 Table 3.1-4. Summary of Groundwater Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 23.87 24.04 23.80 23.84 23.93 23.92 23.50 23.40 23.48 24.06 23.80 24.17 pH SU 7.24 6.61 6.80 7.10 6.81 6.90 7.22 7.20 6.64 11.86 7.10 6.87 Dissolved Oxygen mg/L 0.53 0.79 0.48 0.35 0.73 0.21 0.37 0.37 0.97 0.43 0.45 0.73 Specific Conductance S/cm 1012 32620 34101 1211 22635 23241 527 534 3029 1978 J

629 655 Turbidity NTU 0.38 0.21 0.22 0.01 J

0.00 J

0.06 0.42 0.36 0.12 0.41 0.04 0.14 Calcium mg/L 109 578 566 124 478 494 86 85 85 261 175 J

112 103 Magnesium mg/L 7.2 632 687 12.1 412 439 4.27 4.04 4.04 11.5 0.02 UJ 4.18 5.65 Potassium mg/L 5.8 142 176 4.65 101 107 7.7 7.57 7.44 8.38 10.2 J

11.4 9.11 Sodium mg/L 86 6060 6570 104 3910 4160 20 20 20 278 18 J

17 24 Boron mg/L 0.07 0.99 1.35 0.06 0.80 0.85 0.05 0.05 0.05 0.06 0.05 0.07 0.07 Strontium mg/L 1.07 7.37 7.80 1.23 7.97 8.23 0.84 0.83 0.82 2.64 0.62 1.13 1.04 Bromide mg/L 0.6 40.2 43.9 0.8 27.0 27.7 0.2 0.2 0.2 2.9 0.2 J

0.2 0.3 Chloride mg/L 165 11300 12400 212 7740 8070 34 35 35 825 35 J

31 43 Fluoride mg/L 0.119 0.125 0.142 0.121 0.127 0.140 0.133 0.121 0.121 0.091 I

0.090 IJ 0.095 I

0.093 I

Sulfate mg/L 19 1320 1490 9

835 871 22 25 25 19 50 J

66 57 Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L 237 232 217 289 202 J

217 J

201 200 200 174 257 J

220 226 Bicarbonate Alkalinity mg/L as CaCO3 237 232 217 289 202 J

217 J

210 200 200 174 1

UJ 220 226 Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 553 19300 20900 693 14700 15700 272 272 252 2200 410 J

340 344 Salinity 0.49 J

20.38 21.39 0.6 J

13.65 14.05 0.25 J

0.26 J

1.58 J

1.01 J

0.3 J

0.32 J

Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030414-DUP1 is a duplicate of TPGW-2M.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

03/05/2014 03/05/2014 TPGW-7M 03/10/2014 03/11/2014 03/11/2014 03/11/2014 03/11/2014 03/10/2014 03/10/2014 03/11/2014 03/05/2014 03/11/2014 TPGW-7S TPGW-8D TPGW-8S TPGW-7D TPGW-8M TPGW-6D TPGW-6M TPGW-6S TPGW-5M TPGW-5S 031114-DUP 03/11/2014 TPGW-5D

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-27 Table 3.1-4. Summary of Groundwater Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 24.42 23.84 23.74 26.19 26.36 26.16 25.58 25.56 25.58 26.39 26.02 25.97 pH SU 6.72 6.76 6.95 7.32 7.33 7.00 6.98 6.67 6.81 6.48 6.64 7.09 Dissolved Oxygen mg/L 0.53 1.11 0.46 0.31 0.21 0.35 0.42 0.30 0.11 0.62 0.72 0.13 Specific Conductance S/cm 594 596 625 52152 54497 66201 54319 56935 61402 44292 61622 64257 Turbidity NTU 0.15 2.01 0.10 0.30 0.40 0.37 0.49 0.23 0.22 0.17 0.01 J

0.01 J

Calcium mg/L 117 128 112 434 448 564 500 549 591 J

481 J

565 596 Magnesium mg/L 2.7 3.03 3.47 1190 1200 1500 1210 1290 1370 J

979 J

1370 1480 Potassium mg/L 5.47 5.81 3.8 436 447 553 457 470 511 J

328 J

475 516 Sodium mg/L 12 13 15 11000 11300 13900 11500 12000 13400 J

8560 J

12600 13400 Boron mg/L 0.05 0.06 0.05 4.67 4.83 5.73 5.10 5.06 5.23 3.50 4.91 5.23 Strontium mg/L 0.97 1.07 1.13 8.08 8.49 10.60 8.66 9.52 10.40 7.33 10.00 10.60 Bromide mg/L 0.2 0.2 0.4 68.3 73.6 91.0 72.3 75.7 83.4 J

54.2 J

80.5 120.0 Chloride mg/L 20 22 27 19300 21100 25800 20500 21900 32800 J

16800 J

23200 25900 Fluoride mg/L 0.099 I

0.093 I

0.085 I

0.783 0.595 0.263 J

0.809 0.567 0.654 J

0.414 J

0.259 J-0.250 J

Sulfate mg/L 7

11 30 2740 2780 3570 2870 3160 3310 J

2180 J

3210 3600 Total Ammonia mg/L as N 0.382 0.391 0.811 J

Ammonium ion (NH4

+)

mg/L 0.49 0.50 1.04 J

Unionized NH3 mg/L 0.00592 0.00627 0.00604 J

Nitrate/Nitrite mg/L as N 0.0270 U

0.0270 U

0.0270 U

TKN mg/L 0.76 0.64 1.11 TN mg/L 0.79 0.67 1.14 ortho-Phosphate mg/L 0.0461 J

0.0202 J

0.0452 J

Total Phosphorus (P) mg/L 0.0022 UJ 0.0022 UJ 0.0039 IJ Alkalinity mg/L 278 273 262 129 116 158 289 341 275 J

556 J

267 J

197 J

Bicarbonate Alkalinity mg/L as CaCO3 278 273 262 129 116 158 289 341 275 J

556 J

267 J

197 J

Sulfide mg/L 1.28 1.00 U

1.00 U

4.32 1.00 U Q 3.84 11.20 6.72 Q

4.97 Q

19.40 4.09 Q

1.00 U Q Total Dissolved Solids mg/L 280 280 304 32900 36800 45000 35500 37400 42900 28900 44100 45300 Salinity 0.29 J

0.29 J

0.3 J

34.29 36.03 44.94 35.92 37.88 41.26 28.55 41.44 43.44 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030414-DUP1 is a duplicate of TPGW-2M.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

03/12/2014 03/12/2014 03/12/2014 03/12/2014 03/12/2014 03/12/2014 03/05/2014 03/05/2014 03/10/2014 03/10/2014 03/10/2014 03/05/2014 TPGW-12S TPGW-11M TPGW-11S TPGW-10S TPGW-9D TPGW-9M TPGW-9S TPGW-12D TPGW-11D TPGW-10D TPGW-10M TPGW-12M

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-28 Table 3.1-4. Summary of Groundwater Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 29.47 29.50 29.43 25.82 25.56 26.08 pH SU 6.76 6.76 7.03 6.96 6.83 6.71 Dissolved Oxygen mg/L 0.30 0.45 0.13 0.30 0.25 0.42 Specific Conductance S/cm 82533 78500 79151 56577 60817 73672 Turbidity NTU 0.01 J

0.02 0.19 0.23 0.25 0.34 Calcium mg/L 714 696 686 526 567 649 0.100 U

0.100 U

0.100 U

0.100 U

0 U

Magnesium mg/L 2000 1850 1870 1310 1340 1660 0.0200 U

0.0200 U

0.0200 U

0.0200 U

0 U

Potassium mg/L 710 651 658 474 509 632 0.190 U

0.190 U

0.190 U

0.190 U

0 U

Sodium mg/L 17800 16600 17200 12200 13100 16000 0.310 U

0.310 U

0.310 U

0.310 U

0 U

Boron mg/L 7.45 6.75 7.13 5.03 5.37 6.69 0.01 0.01 0.01 0.01 0

U Strontium mg/L 14.30 14.20 14.10 9.37 10.10 12.90 0.00 0.00 0.00 0.00 0

U Bromide mg/L 115.0 108.0 109.0 76.0 83.1 103.0 0.0130 U

0.0130 U

0.0130 U

0.0130 U

0.0 U

Chloride mg/L 32900 31500 31400 20900 24100 29200 0.476 I

0.250 U

0.250 U

0.250 U

0 U

Fluoride mg/L 0.339 0.196 0.210 0.514 0.431 J

0.397 J

0.0240 U

0.0240 U

0.0240 U

0.0240 U

0.024 U

Sulfate mg/L 4680 4320 4220 3170 3340 4060 0.250 U

0.250 U

0.304 I

0.250 U

0 U

Total Ammonia mg/L as N 2.540 1.820 1.100 0.647 1.160 J

1.050 J

0.0260 U

0.0260 U

0.0260 U

0.0260 U

0.0260 U

Ammonium ion (NH4

+)

mg/L 3.25 2.33 1.40 0.83 1.49 J

1.35 J

Unionized NH3 mg/L 0.01370 0.00986 0.01100 0.00430 0.00562 J

0.00400 J

Nitrate/Nitrite mg/L as N 0.0335 I

0.0270 U

0.0391 I

0.0270 U

0.0270 U

0.0270 U

0.02700 U

0.02700 U

0.02700 U

0.02700 U

0.02700 U

TKN mg/L 2.74 2.27 2.65 0.99 1.51 3.09 0.300 U

0.300 U

0.300 U

0.300 U

0.30 U

TN mg/L 2.77 2.30 2.69 1.02 1.54 3.12 0.33 0.33 0.33 0.33 0.33 ortho-Phosphate mg/L 0.0533 J

0.0043 I J 0.0127 J

0.0434 J

0.0665 J

0.0563 J

0.00324 I

0.00413 I

0.00399 I

0.00179 I

0.00293 I

Total Phosphorus (P) mg/L 0.0052 IJ 0.0075 I

0.0022 UJ 0.0022 UJ 0.0025 IJ 0.0044 IJ 0.00220 U

0.00220 U

0.00220 U

0.00220 U

0.00220 U

Alkalinity mg/L 116 J

178 J

188 J

236 284 225 1.00 U

27.60 1.00 U

1.00 U

1 U

Bicarbonate Alkalinity mg/L as CaCO3 116 J

178 J

188 J

236 284 255 1.00 U

27.60 1.00 U

1.00 U

1 U

Sulfide mg/L 5.71 1.00 U Q 1.00 U Q 4.74 Q

7.59 Q

4.26 Q

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 60300 55700 59100 36800 41400 51400 5

U 5

U 5

U 5

U 5

U Salinity 57.81 54.54 55.07 37.6 40.81 50.8 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030414-DUP1 is a duplicate of TPGW-2M.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

031214-FB1 03/12/2014 031014-FB1 03/11/2014 03/12/2014 03/12/2014 03/12/2014 03/04/2014 03/10/2014 031114-FB1 03/05/2014 03/05/2014 03/05/2014 03/05/2014 030514-FB1 TPGW-14M TPGW-14S TPGW-14D 030414-FB1 TPGW-13S TPGW-13D TPGW-13M

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-29 Table 3.1-5. Summary of Groundwater Analytical Results from the June 2013 Historical Well Sampling Event Parameter Units Temperature

°C 26.39 27.97 27.13 27.75 25.02 25.16 25.57 25.19 24.59 24.87 pH SU 7.14 6.86 7.2 6.84 6.9 6.64 7.94 6.79 6.94 7.16 Dissolved Oxygen mg/L 0.4 J

0.23 J

1.23 J

0.29 J

0.56 0.36 0.28 0.31 0.35 0.32 Specific Conductance S/cm 1179 79416 547 74968 518 17408 7850 39487 634 14447 Turbidity NTU 3.01 0.14 1.66 0.15 0.71 0.32 59.73 27.6 0.94 0.3 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 123 19500 41.2 18400 23.2 22.9 2820 1190 7460 26.8 2450 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 240 32700 78.4 30900 51.7 48 6250 2670 16000 48.4 J+

5070 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 627 50600 296 48500 268 264 12000 4460 24300 348 8300 Salinity 0.58 J

55.34 0.26 J

51.78 0.25 J

10.24 4.34 25.15 0.31 J

8.37 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

KEY:

°C = Degrees Celsius.

mg/L = Milligram(s) per liter.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

N = Nitrogen.

SU = Standard Unit(s).

= sigma (Standard Deviation).

NH3 = Ammonia.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH4

+ = Ammonium ion.

TN = Total nitrogen.

J = Estimated (+/- indicate bias).

NTU = Nephelometric Turbidity Units(s).

TPGW = Turkey Point Groundwater.

6/10/2013 6/10/2013 TPGW-G35-18 6/10/2013 6/10/2013 6/10/2013 TPGW-G28-58 6/10/2013 6/10/2013 061013-DUP1 TPGW-G35-58 TPGW-G21-18 TPGW-G21-58 TPGW-G28-18 TPGW-L3-18 TPGW-L3-58 TPGW-L5-18 TPGW-L5-58 6/7/2013 6/7/2013 6/7/2013 6/7/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-30 Table 3.1-6. Summary of Groundwater Analytical Results from the September 2013 Historical Well Sampling Event Parameter Units Temperature

°C 27.92 28.67 29.60 28.86 26.19 25.81 25.93 25.75 24.88 24.77 pH SU 7.37 6.89 7.26 6.87 7.28 6.71 8.25 6.84 7.23 7.17 Dissolved Oxygen mg/L 0.15 0.22 0.14 0.20 0.20 J

0.04 J

0.19 J

0.03 J

0.21 J

0.31 J

Specific Conductance S/cm 704 79173 1727 75809 532 17131 5034 39083 592 17918 Turbidity NTU 2.53 0.06 0.72 0.07 1.42 0.53 19.45 10.00 0.27 0.22 Silica, dissolved mg/L Calcium mg/L 67.4 677 83.9 735 87.5 87.0 635 259 593 90.7 313 0.100 U

0.100 U

Magnesium mg/L 7.69 1790 22.8 1810 3.82 3.80 221 70.0 807 5.59 342 0.0200 U

0.0200 U

Potassium mg/L 2.49 671 9.30 671 4.54 4.43 25.7 14.5 198 9.42 102 0.190 U

0.190 U

Sodium mg/L 66.3 16900 225 17100 23.9 23.5 2690 988 7140 21.3 3000 0.310 U

0.310 U

Boron mg/L 0.0457 I

7.09 0.105 6.87 0.064 0.048 I

0.155 I

0.195 I

1.43 0.0655 1.53 0.01 U

0.01 U

Strontium mg/L 0.644 13 0.88 15.2 0.771 0.769 6.52 2.35 7.17 0.858 4.59 0.001 U

0.001 U

Bromide mg/L 0.379 117 1.57 108 0.224 0.214 21.6 7.57 45.4 0.315 21.7 0.0130 U

0.0130 U

Chloride mg/L 134 34800 443 33300 46.6 45.1 6440 2210 15300 37.6 6490 0.250 U

0.250 U

Fluoride mg/L 0.0923 I

0.299 0.0923 I

0.193 0.118 0.114 0.0870 I

0.0783 I

0.131 0.126 0.159 0.0240 U

0.0240 U

Sulfate mg/L 2.11 4350 32.2 4080 10.5 J

8.48 J

216 173 1730 59.9 867 0.250 U

0.250 U

Total Ammonia mg/L as N 0.0260 U

0.0261 I

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.00760 I

0.00540 U

TKN mg/L 0.366 0.255 TN mg/L ortho-Phosphate mg/L 0.00140 U

0.00140 U

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U

Alkalinity mg/L 153 185 181 189 204 201 201 118 212 176 167 1.00 U

1.00 U

Bicarbonate Alkalinity mg/L as CaCO3 153 185 181 189 204 201 201 118 212 176 167 1.00 U

1.00 U

Sulfide mg/L 1.12 1.67 1.12 1.00 U

1.15 1.00 U

1.00 U

1.28 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 412 56600 890 52000 292 288 10900 4120 24100 324 10300 Salinity 0.34 J

55.12 0.87 J

52.41 0.26 J

10.08 3.43 24.83 0.29 J

10.58 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 090913-DUP1 is a duplicate of G21-18.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter. mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

I = Value between the MDL and PQL.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

09/10/2013 09/10/2013 09/10/2013 09/09/2013 09/09/2013 TPGW-G35-18 090913-DUP TPGW-G21-18 09/09/2013 09/09/2013 09/09/2013 090913-FB1 091013-FB1 09/09/2013 09/10/2013 TPGW-L5-58 09/10/2013 09/09/2013 09/09/2013 TPGW-G35-58 TPGW-L3-18 TPGW-L3-58 TPGW-L5-18 TPGW-G21-58 TPGW-G28-18 TPGW-G28-58

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-31 Table 3.1-7. Summary of Groundwater Analytical Results from the December 2013 Historical Well Sampling Event Parameter Units Temperature

°C 27.16 27.58 27.28 27.85 25.22 24.86 25.04 24.99 24.67 24.54 pH SU 6.92 6.80 7.18 6.80 6.94 6.64 7.93 6.86 7.10 7.12 Dissolved Oxygen mg/L 0.44 0.31 0.29 0.32 0.64 0.42 0.37 0.83 0.36 0.32 Specific Conductance S/cm 2298 78688 980 74021 579 17273 5610 38640 645 18389 Turbidity NTU 1.34 0.01 J

0.99 0.01 J

1.31 0.4 105.40 47.70 1.75 0.01 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 292.0 16900 93 15900 24.8 2880.0 941 7070 31 30.5 3150 0.310 U

0.310 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 556 33000 189 30200 45.6 5540.0 1910 14900 56 60.4 6230 0.250 U

0.250 U

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as Sulfide mg/L Total Dissolved Solids mg/L 940 57100 480 52700 308 9700 3140 24200 336 320 9600 5

U 5

U Salinity 1.17 J

54.77 0.48 J

51.02 0.2 J

10.16 3.03 24.56 0.31 J

10.88 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 120613-DUP1 is a duplicate of 120613-TPGW-G35-18.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimetermg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

TPGW-L3-18 12/06/2013 12/06/2013 TPGW-G21-18 12/06/2013 TPGW-G35-58 TPGW-L3-58 12/06/2013 12/05/2013 12/05/2013 12/06/2013 12/06/2013 12/05/2013 12/05/2013 TPGW-G28-58 12/06/2013 TPGW-G21-58 120513-FB1 120613-FB1 120613-DUP TPGW-L5-18 TPGW-L5-58 12/06/2013 TPGW-G28-18 TPGW-G35-18 12/05/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-32 Table 3.1-8. Summary of Groundwater Analytical Results from the March 2014 Historical Well Sampling Event Parameter Units Temperature

°C 26.19 26.86 24.50 25.54 24.61 24.37 25.26 24.90 25.21 24.62 pH SU 7.24 6.95 7.36 6.87 7.40 6.7 9.46 6.92 7.56 7.10 Dissolved Oxygen mg/L 0.47 0.56 0.61 0.43 0.88 0.4 4.58 0.45 0.77 0.35 Specific Conductance S/cm 837 77142 799 72566 538 16305 1673 38299 755 18096 Turbidity NTU 0.81 0.12 0.75 0.07 0.51 0.09 0.85 81.31 1.10 0.25 Silica, dissolved mg/L 0.05 U

0.05 U

Calcium mg/L 79.4 671 80.8 669 80.5 581.0 98 587 69 67.9 307 0.100 U

0.100 U

Magnesium mg/L 10.80 1790 9.5 1660 3.80 180.00 22 802.0 8

7.52 340 0.0200 U

0.0200 U

Potassium mg/L 3.57 667 3.30 594 4.53 29.00 8.3 208.0 13 12.30 114 0.190 U

0.190 U

Sodium mg/L 76.0 17100 68 16200 J

23.6 2700.0 350 7540 66 65.2 3350 0.310 U

0.310 U

Boron mg/L 0.0586 6.99 0.0643 6.06 0.0409 I

0.151 0.139 1.53 0.0857 0.0846 1.66 0.01 U

0.01 U

Strontium mg/L 0.767 13.5 0.791 15.1 0.833 7.27 1.1 8.15 0.957 0.95 5.21 0.001 U

0.001 U

Bromide mg/L 0.346 109 0.36 103 0.189 20.500 2.4 49.50 0.6 0.585 20.9 0.0130 U

0.0130 U

Chloride mg/L 141 31700 122 28800 42.9 5810.0 676 13800 116 117.0 6020 0.250 U

0.364 I

Fluoride mg/L 0.0915 I

0.317 J

0.0797 I

0.180 J-0.121 0.091 I

0.0451 I

0.1420 0.138 0.142 0.162 0.0240 U

0.0240 U

Sulfate mg/L 20.60 4550 10.3 J

3970 14.7 209.00 104 1760 76 76.7 925 0.338 I

1.110 Total Ammonia mg/L as N 0.0260 U

0.0260 U

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.03780 I

0.05550 TKN mg/L 0.300 U

0.300 U

TN mg/L 0.3378 0.3555 ortho-Phosphate mg/L 0.00190 I

0.00140 U

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U

Alkalinity mg/L 187 183 210 192 196 203 76 217 115 118 170 1.00 U

1.00 U

Sulfide mg/L 1.00 U Q 1.00 U Q 1.84 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 440 55300 368 50800 276 10400 960 23700 368 348 10100 5

U 5

U Salinity 0.41 J

53.55 0.39 J

49.93 0.26 J

9.56 0.84 J

24.33 0.37 J

10.69 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030614-DUP1 is a duplicate of G35-18.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

030614-FB1 030714-FB1 03/06/2014 03/07/2014 TPGW-L5-58 03/07/2014 03/06/2014 03/06/2014 TPGW-G35-58 TPGW-L3-18 TPGW-L3-58 TPGW-L5-18 TPGW-G28-18TPGW-G28-58TPGW-G35-18 030614-DUP TPGW-G21-58 TPGW-G21-18 03/06/2014 03/06/2014 03/06/2014 03/07/2014 03/07/2014 03/07/2014 03/06/2014 03/06/2014

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-33 Table 3.1-9. Range of Ion and Nutrient Concentrations in Groundwater Parameter Units Min Max Average Std Dev Min Max Average Std Dev Min Max Average Std Dev Min Max Average Std Dev Min Max Average Std Dev Min Max Average Std Dev Temperature

°C 23.80 28.86 26.08 1.02 18.32 29.40 25.89 1.66 23.40 29.60 24.93 1.03 22.05 30.12 24.82 1.14 28.75 29.58 29.30 0.30 28.83 30.47 29.73 0.44 pH SU 6.48 7.53 6.87 0.20 6.45 7.64 7.01 0.21 6.64 11.86 7.27 1.04 6.74 12.10 7.57 1.15 6.73 7.03 6.84 0.08 6.52 7.25 7.01 0.15 Dissolved Oxygen mg/L 0.03 1.93 0.42 0.33 0.05 1.67 0.25 0.20 0.03 4.58 0.53 0.54 0.05 1.29 0.26 0.22 0.02 1.10 0.33 0.30 0.06 1.08 0.26 0.30 Specific Conductance S/cm 22635 79416 57502 15860 19640 84800 56598 16703 518 39487 4645 9325 429 41949 4462 8946 78333 83887 80743 2011 70180 90261 82289 5029 Turbidity NTU 0.00 1.42 0.23 0.23 0.00 7.40 0.80 1.03 0.00 105.40 4.92 17.03 0.00 31.92 2.64 4.88 0.01 1.07 0.16 0.30 0.00 1.55 0.51 0.45 Calcium mg/L 411.00 1080.00 597.86 99.41 400.00 870.00 597.40 88.82 67.40 635.00 171.50 156.26 48.00 590.00 165.34 134.37 686.00 758.00 711.50 26.50 690.00 790.00 746.19 32.01 Magnesium mg/L 403.00 1810.00 1295.64 410.84 420.00 2200.00 1438.18 495.24 0.02 807.00 75.26 188.78 0.02 910.00 66.79 181.31 1720.00 2010.00 1883.33 108.38 2000.00 2500.00 2233.33 115.47 Potassium mg/L 101.00 671.00 456.53 175.00 92.00 1400.00 446.03 192.77 2.49 208.00 22.79 47.63 2.60 440.00 23.29 55.54 651.00 753.00 692.83 37.57 600.00 800.00 709.52 52.96 Sodium mg/L 3790.00 18900.00 11840.52 3828.98 3800.00 21000.00 11660.42 3920.32 8.05 7540.00 619.95 1551.72 6.00 8300.00 642.26 1593.12 16500.00 18100.00 17083.33 547.45 16000.00 20000.00 17857.14 1195.23 Boron mg/L 0.79 7.09 4.61 1.95 0.58 7.50 4.38 1.94 0.03 1.66 0.22 0.45 0.03 1.60 0.19 0.40 6.75 7.55 7.13 0.32 6.60 8.70 7.51 0.61 Strontium mg/L 6.09 15.20 10.31 2.36 6.30 15.00 10.23 2.36 0.58 8.15 1.87 2.06 0.53 7.70 1.76 1.79 13.40 14.30 14.02 0.33 14.00 16.00 14.43 0.60 Bromide mg/L 26.50 120.00 78.24 25.30 23.00 180.00 76.60 29.66 0.15 49.50 5.16 11.68 0.03 62.00 4.26 11.00 108.00 122.00 113.83 5.12 49.00 130.00 108.57 16.91 Chloride mg/L 7740 34800 23268 7254 7100 34000 22247 7492 16 16000 1540 3592 10 15000 1358 3279 31400 39800 34925 2604 26000 38000 34476 2750 Fluoride mg/L 0.12 0.81 0.31 0.19 0.01 3.30 0.44 0.55 0.05 0.16 0.11 0.02 0.02 0.65 0.13 0.11 0.19 0.35 0.25 0.07 0.02 3.60 0.80 1.04 Sulfate mg/L 825.00 4550.00 2998.33 1035.81 680 4500.00 2734.61 1005.28 2.11 1760.0 171.7 414.1 0.92 1800 156 369 4120 4820 4457 278 3700.0 5000.0 4257.1 395.7 Total Ammonia mg/L as N 0.298 2.080 1.156 0.550 0.220 2.000 1.097 0.600 NA NA NA NA NA NA NA NA 1.100 2.590 1.872 0.593 1.300 2.800 1.844 0.482 Ammonium ion (NH4

+)

mg/L 0.378 2.670 1.478 0.705 0.280 2.600 1.378 0.794 NA NA NA NA NA NA NA NA 1.400 3.310 2.392 0.761 1.656 3.600 2.336 0.627 Unionized NH3 mg/L 0.003 0.015 0.008 0.003 0.003 0.025 0.010 0.006 NA NA NA NA NA NA NA NA 0.010 0.014 0.012 0.002 0.014 0.184 0.039 0.055 Nitrate/Nitrite mg/L as N 0.005 0.128 0.028 0.023 0.005 1.200 0.093 0.239 NA NA NA NA NA NA NA NA 0.027 0.089 0.046 0.022 0.012 0.340 0.104 0.110 Total Kjedahl Nitrogen mg/L 0.640 3.160 1.923 0.852 0.260 2.700 1.425 0.793 NA NA NA NA NA NA NA NA 2.270 4.270 2.995 0.684 1.500 3.500 2.333 0.608 Total Nitrogen mg/L 0.667 3.187 1.951 0.849 0.260 2.700 1.442 0.788 NA NA NA NA NA NA NA NA 2.297 4.310 3.041 0.688 1.500 3.800 2.433 0.680 ortho-Phosphate mg/L 0.00 0.08 0.04 0.02 0.014 0.10 0.04 0.02 NA NA NA NA NA NA NA NA 0.00 0.05 0.02 0.02 0.02 0.04 0.03 0.00 Total Phosphorus (P) mg/L 0.00 0.06 0.02 0.02 0.015 0.08 0.03 0.01 NA NA NA NA NA NA NA NA 0.00 0.04 0.02 0.02 0.04 0.07 0.05 0.01 Alkalinity mg/L 103.00 562.00 234.33 89.89 48 550.00 209.68 73.09 75.50 332.00 216.41 54.45 30.00 580 224.73 83.32 116 190 174 29 54.00 220.00 165.43 36.07 Bicarbonate Alkalinity mg/L as CaCO3 103.00 562.00 234.84 89.92 48.0 550.00 209.68 73.09 1.00 332.00 205.71 71.76 1.00 360 200.17 72.78 116 190 174 29 54.00 220.0 165.4 36.1 Sulfide mg/L 1.00 22.00 4.04 5.04 1.0 22.00 3.22 4.03 1.00 1.84 1.08 0.16 1.00 8.30 1.11 0.73 1.00 9.45 3.19 3.60 1.00 25.00 7.14 9.13 Total Dissolved Solids mg/L 12800 57100 38428 11929 12000 64000 38208 12850 236 24300 2746 5756 160 26000 2558 5486 54000 60300 57000 2180 56000 75000 60857 5842 Salinity (PSS-78) 13.65 55.34 38.61 11.70 11.68 59.82 37.96 12.31 0.20 25.15 2.75 5.86 0.21 26.93 2.62 5.63 54.43 58.93 56.37 1.63 47.90 64.20 57.63 4.07 Tritium pCi/L (1)

NOTES:

  • PSS-78 salinity is unitless.

Marine wells include: TPGW-1S, -1M, -1D, -2S, -2M, -2D, -3S, -3M, -3D, -4M, -4D, -5M, -5D, -6M, -6D, -10S, -10M, -10D, -11S, -11M, -11D, -12S, -12M, -12D, -14S, -14M, -14D Fresh wells include: TPGW-4S, -5S, -6S, -7S, -7M, -7D, -8S, -8M, -8D, -9S, -9M, -9D, -L3-18, -L5-18, -G21-18, -G21-58, -G28-18, -G28-58, -G35-18, -G35-58 KEY:

°C = Degrees Celsius.

Min = Minimum.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

N = Nitrogen.

SU = Standard Unit(s).

= sigma (Standard Deviation).

NA = Not available.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

Max = Maximum.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

mg/L = Milligram(s) per liter.

NTU = Nephelometric Turbidity Units(s).

Post-Uprate Post-Uprate Marine Fresh TPGW-13 Post-Uprate Pre-Uprate Pre-Uprate Pre-Uprate

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-34 Table 3.2-1. Summary of Surface Water Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 28.52 29.14 29.47 29.49 26.7 28.6 28.08 28.35 28.46 27.11 27.16 29.83 27.19 pH SU 7.85 7.68 7.79 7.77 7.14 7.68 7.56 7.6 7.59 6.9 6.92 7.83 7.49 Dissolved Oxygen mg/L 4.21 5.32 5.22 6.71 J

1.12 J

5.42 J

5.04 J

6 J

7.1 J

2.1 0.19 6.67 2.43 Specific Conductance S/cm 53783 52173 46171 402 442 582 570 556 555 42969 48000 50933 J

55524 Turbidity NTU 1.94 1.24 0.79 0.65 1.34 0.69 1.11 0.59 0.51 1.58 8.23 0.73 6.73 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 10800 10600 8610 8900 30.9 32.6 54.8 55.4 50.4 51.4 8460 9560 9570 11500 10300 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 20900 21300 17000 17900 53.9 55.2 106 106 95.6 95.4 16300 19500 18700 22900 J

21500 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L Salinity 35.4 34.2 29.8 0.2 J

0.2 J

0.3 J

0.3 J

0.3 J

0.3 J

27.6 31.3 33.3 J

36.8 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

061113-DUP1 is a field duplicate of sample 061113-TPSWC-4B.

061313-DUP1 is a field duplicate of sample 061313-TPBBSW-5B.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

FB = Field blank.

TPBBSW-3B 6/13/2013 6/13/2013 6/7/2013 061113-DUP1 TPSWC-5T 6/11/2013 6/13/2013 TPSWC-1B TPSWC-5B TPSWC-2B 6/7/2013 TPSWC-4T 6/11/2013 TPSWC-4B 6/13/2013 6/11/2013 TPSWC-3T 6/7/2013 TPBBSW-4B 061313-Dup1 TPSWC-2T TPBBSW-5B TPSWC-3B 6/11/2013 TPSWC-1T 6/7/2013 6/7/2013 6/7/2013 6/11/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-35 Table 3.2-1. Summary of Surface Water Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 25.23 25.18 36.14 29.14 29.35 28.13 28.72 27.59 40.33 36.51 33.55 31.51 32.47 37.76 pH SU 7.23 7.25 8.06 7.85 7.85 7.01 7.64 7.72 8.87 8.56 8.69 8.69 8.67 8.84 Dissolved Oxygen mg/L 2.62 2.17 5.79 5.17 6.25 0.43 4.74 5.02 4.28 8.45 4.86 5.55 5.14 6.38 Specific Conductance S/cm 808 818 4088 6510 3293 13700 3644 4006 75276 75280 74015 74816 74451 75876 Turbidity NTU 0.51 0.41 0.74 0.9 0.41 20.55 0.51 0.39 32.12 28.15 39.69 39.85 31.7 32.17 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 50 51.2 588 997 467 2300 497 571 15400 15700 15300 15500 15300 15300 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 83.2 89.5 1210 1920 885 4300 969 1120 31000 33400 30200 32100 29800 30600 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L Salinity 0.4 J

0.4 J

2.2 3.5 1.7 J

7.9 1.9 J

2.1 51.4 51.6 50.8 51.5 51.2 51.4 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

061113-DUP1 is a field duplicate of sample 061113-TPSWC-4B.

061313-DUP1 is a field duplicate of sample 061313-TPBBSW-5B.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

FB = Field blank.

6/3/2013 TPSWCCS-4T 6/3/2013 TPSWID-3T TPSWC-6T TPSWID-2B TPSWID-1T TPSWID-1B TPSWC-6B TPSWCCS-1B TPSWID-2T TPSWID-3B TPSWCCS-3B TPSWCCS-2B TPSWCCS-5T TPSWCCS-7B 6/11/2013 6/3/2013 6/3/2013 6/3/2013 6/3/2013 6/3/2013 6/3/2013 6/5/2013 6/5/2013 6/3/2013 6/3/2013 6/3/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-36 Table 3.2-1. Summary of Surface Water Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C pH SU Dissolved Oxygen mg/L Specific Conductance S/cm Turbidity NTU Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N 0.026 U

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.005 U

TKN mg/L 0.236 TN mg/L ortho-Phosphate mg/L 0.001 U

Total Phosphorus (P) mg/L 0.002 U

Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 5

U 5

U Salinity Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

061113-DUP1 is a field duplicate of sample 061113-TPSWC-4B.

061313-DUP1 is a field duplicate of sample 061313-TPBBSW-5B.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

FB = Field blank.

061313-FB1 6/13/2013 060713-FB1 060313-FB1 6/3/2013 061113-EB1 6/11/2013 060513-FB1 6/5/2013 6/7/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-37 Table 3.2-2. Summary of Surface Water Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 29.10 28.42 28.29 28.71 28.54 28.83 29.00 29.93 29.56 29.06 29.92 30.60 30.71 pH SU 8.13 8.04 7.88 7.48 7.32 7.73 7.54 7.78 7.68 7.48 7.63 7.94 7.76 Dissolved Oxygen mg/L 5.30 5.29 4.41 3.47 1.65 4.77 2.74 5.02 4.24 2.86 3.23 5.14 4.04 Specific Conductance S/cm 49303 J

52612 J

50460 J

576 593 578 588 608 614 23204 J

47521 J

52069 J

53157 J

Turbidity NTU 0.92 0.77 1.10 0.54 1.17 1.19 0.84 0.63 0.52 2.40 9.43 0.56 1.01 Silica, dissolved mg/L Calcium mg/L 410 408 396 54.3 53.6 53.9 50.2 51.7 52.5 52.2 251 394 415 443 Magnesium mg/L 1110 J-1110 J-1070 J-6.93 6.76 6.80 6.43 6.62 6.26 6.09 420 954 1120 1190 Potassium mg/L 413 436 427 2.39 2.34 2.34 2.59 2.81 2.73 2.62 169 386 430 437 Sodium mg/L 9610 10100 9710 50.5 52.0 52.4 53.5 54.0 56.2 55.7 4000 9100 10200 10300 Boron mg/L 4.32 4.82 4.49 0.0428 I

0.0425 I

0.043 I

0.037 I

0.0395 I

0.0376 I

0.0362 I

1.74 3.96 4.52 4.51 Strontium mg/L 7.01 7.24 7.14 0.518 0.512 0.514 0.536 0.567 0.555 0.544 3.92 6.55 7.1 7.42 Bromide mg/L 68.3 J

70.8 J

70.1 J

0.178 0.207 0.208 0.207 0.227 0.265 0.279 28.2 J

65.3 J

70.6 J

72.5 J

Chloride mg/L 19900 J

21200 J

20600 J

113 119 120 117 118 122 116 9050 J

18000 J

20900 J

21500 J

Fluoride mg/L 0.856 J

0.889 J

0.893 J

0.0636 I

0.0664 I

0.0741 I

0.0773 I

0.0786 I

0.0760 I

0.0744 I

0.345 J

0.757 J

0.835 J

0.807 J

Sulfate mg/L 2580 J

2730 J

2620 J

1.16 1.03 1.11 1.42 0.713 4.71 3.11 1040 J

2310 J

2670 J

2750 J

Total Ammonia mg/L as N 0.0426 I J 0.0415 I J 0.0408 I J 0.174 J

0.233 J

0.230 0.154 J

0.166 J

0.131 J

0.132 J

0.240 0.0780 0.0361 I

0.0260 U

Ammonium ion (NH4

+)

mg/L 0.0497 J

0.0494 J

0.04975 0.219 J

0.295 J

0.190 0.208 0.161 0.164 0.302 0.0970 0.0433 0.0300 U

Unionized NH3 mg/L 0.00480 J

0.00370 J

0.00271 0.00460 J

0.00424 J

0.00718 0.00512 0.00733 0.00578 0.00650 0.00313 0.00299 0

U Nitrate/Nitrite mg/L as N 0.00849 I

0.00540 U

0.00540 U

0.0200 J+ 0.0206 J+

0.0112 J

0.00827 I J+ 0.0109 J+

0.0125 J+

0.0315 J+

0.0267 J+

0.0102 J+

0.0176 J+ 0.00600 I J+

TKN mg/L 1.28 J

0.935 J

0.990 J

1.21 J

2.92 1.29 1.33 J

1.29 J

1.16 J

1.15 J

1.02 0.849 0.549 0.743 J

TN mg/L 1.29 J

0.94 J

1.00 J

1.23 J

2.94 J

1.34 J

1.30 J

1.17 J

1.18 J

1.05 J

0.86 J

0.57 J

0.75 J

ortho-Phosphate mg/L 0.00140 U

0.00140 U

0.00140 U 0.00140 U 0.00140 U 0.00140 U 0.00140 U 0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U

0.00440 U 0.00315 I J- 0.00831 I J- 0.00451 I

0.00289 I J- 0.00220 U J- 0.00220 U J- 0.00220 U J- 0.00220 U J- 0.00220 U J- 0.00220 U J- 0.00220 U J-Alkalinity mg/L 135 J

124 J

129 J

118 118 118 109 114 118 119 240 J

151 J

130 J

143 J

Bicarbonate Alkalinity mg/L as CaCO3 135 J

124 J

129 J

118 118 118 109 114 118 119 240 J

151 J

130 J

143 J

Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L Salinity 32.1 J

34.6 J

33.0 J

0.3 J

0.3 J

0.3 J

0.3 J

0.3 J

0.3 J

14.0 J

30.8 J

34.1 J

34.9 J

Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 091013-DUP is a duplicate of TPSWC-1B.

Sample 091113-DUP2 is a duplicate of TPSWC-5B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

TPSWC-1T TPSWC-1B 09/10/2013 09/10/2013 TPBBSW-3B 09/10/2013 09/10/2013 TPSWC-3B 09/10/2013 TPSWC-2T TPSWC-4B 09/11/2013 09/11/2013 TPSWC-4T 09/11/2013 TPSWC-5B TPBBSW-4B TPBBSW-5B 09/11/2013 09/12/2013 09/12/2013 TPSWC-5T TPSWC-2B 09/10/2013 TPSWC-3T 09/12/2013 091013-DUP 09/10/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-38 Table 3.2-2. Summary of Surface Water Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 25.82 25.83 31.89 30.53 32.30 29.00 31.59 30.01 39.56 34.86 34.35 33.58 33.09 pH SU 7.48 7.38 7.44 7.35 7.44 6.71 7.51 7.03 8.53 8.76 8.49 8.68 8.64 Dissolved Oxygen mg/L 1.49 J

0.94 J

5.52 4.58 5.77 0.42 5.86 1.36 4.68 4.92 6.07 6.72 5.77 Specific Conductance S/cm 750 758 3570 3565 3067 5929 2523 2520 88287 J

88270 J

84330 J

88135 J

87241 J

Turbidity NTU 0.25 0.77 0.60 1.65 0.60 16.17 0.38 0.33 81.66 78.94 76.18 76.24 79.45 Silica, dissolved mg/L 2.62 J-2.66 2.76 J-2.69 J-2.61 J-Calcium mg/L 460 88.5 86.3 109 107 121 195 100 120 783 J

791 J

778 823 830 J

Magnesium mg/L 1130 8.26 8.75 63.1 57.3 49.0 94.8 33.0 38.6 1920 J-1930 J-1920 2050 2090 J

Potassium mg/L 452 9.40 9.47 20.3 20.8 16.3 29.5 14.5 13.8 860 J+

855 J+

769 826 802 J

Sodium mg/L 10400 48.3 54.3 485 491 406 835 331 323 18600 J

18600 J

17200 18200 18200 J

Boron mg/L 4.51 0.0722 0.073 0.238 0.243 0.164 0.268 0.133 0.129 9.11 9.22 8.32 8.73 8.43 Strontium mg/L 7.42 0.943 0.939 1.2 1.21 1.23 2.15 1.21 1.18 16.5 16.4 15.4 16.4 15.8 Bromide mg/L 72.6 0.475 0.513 3.13 3.17 2.71 6.09 2.18 2.17 132 J

133 J

127 J

139 J

136 J

Chloride mg/L 21600 82.6 102 1000 1000 837 1760 676 660 37200 J

40100 J

37700 J

40200 J

38600 J

Fluoride mg/L 0.807 0.121 0.113 0.129 0.133 0.121 0.143 0.108 0.119 0.739 J-0.729 J

0.720 J-0.732 J-0.739 J

Sulfate mg/L 2750 53.0 48.5 93.3 93.0 73.8 156 56.9 56.2 5220 J

5090 J

4990 J

5330 J

5300 J

Total Ammonia mg/L as N 0.0260 U

0.0879 0.0793 0.0931 0.113 0.139 0.435 0.146 0.277 0.0907 J+

0.109 J

0.0952 0.0956 0.0781 Ammonium ion (NH4

+)

mg/L 0.111 0.101 0.117 0.143 0.174 0.557 0.182 0.353 0.0770 J+

0.0853 J

0.0918 0.0824 0.0700 Unionized NH3 mg/L 0.00191 0.00137 0.00278 0.00252 0.00427 0.00203 0.00500 0.00288 0.0374 J+

0.0518 J

0.0289 0.0382 0.0287 Nitrate/Nitrite mg/L as N 0.00753 I

0.0291 J+

0.0289 J+

0.0270 U

0.0270 U

0.0270 U

0.0270 U

0.0421 I

0.0297 I

0.0270 U

0.0270 U

0.0270 U

0.0270 U

0.0400 I

TKN mg/L 2.39 J

0.591 J

0.512 J

0.819 0.890 0.908 1.19 0.767 0.871 14.9 17.7 14.6 14.6 14.8 TN mg/L 0.62 J

0.54 J

0.85 0.92 0.94 1.22 0.81 0.90 14.93 17.73 14.63 14.63 14.84 ortho-Phosphate mg/L 0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00652 I

0.0162 0.00140 U

0.00748 I

0.00811 I

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U J- 0.00220 U J- 0.00361 I

0.00334 I

0.00258 I

0.0101 0.00220 U

0.00277 I

0.0524 0.0460 0.0285 0.0429 0.0625 Alkalinity mg/L 142 192 194 247 251 214 312 206 223 124 J

128 J

132 J

127 J

127 J

Bicarbonate Alkalinity mg/L as CaCO3 142 192 194 247 251 214 312 206 223 76.5 J

39.0 J

70.8 J

28.4 J

27.4 J

Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.25 1.07 1.00 U

2.08 1.00 U

1.15 1.00 U

1.00 U

1.00 U

1.00 U

1.38 Total Dissolved Solids mg/L Salinity 0.4 J

0.4 J

1.9 J

1.9 J

1.6 J

3.2 1.3 J

1.3 J

61.9 J

62.2 J

59.0 J

62.2 J

61.5 J

Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 091013-DUP is a duplicate of TPSWC-1B.

Sample 091113-DUP2 is a duplicate of TPSWC-5B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

TPSWID-2B 091113-DUP2 09/11/2013 TPSWC-6B TPSWC-6T 09/09/2013 TPSWID-3T 09/05/2013 TPSWID-1B TPSWID-1T 09/05/2013 TPSWCCS-3B TPSWID-2T 09/05/2013 TPSWCCS-4T TPSWCCS-1B TPSWCCS-5T 09/09/2013 09/05/2013 09/05/2013 09/05/2013 TPSWID-3B 09/05/2013 09/05/2013 09/05/2013 TPSWCCS-2B 09/06/2013 09/05/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-39 Table 3.2-2. Summary of Surface Water Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 36.97 pH SU 8.55 Dissolved Oxygen mg/L 5.45 Specific Conductance S/cm 88914 J

Turbidity NTU 83.28 Silica, dissolved mg/L 2.53 J-0.0500 U

0.0500 U

Calcium mg/L 830 J

0.100 U

0.100 U

0.100 U

0.100 U

0.100 U

0.100 U

Magnesium mg/L 2050 J

0.0200 U

0.0267 I

0.0200 U

0.0200 U

0.0200 U

0.0200 U

Potassium mg/L 817 J

0.190 U

0.190 U

0.190 U

0.190 U

0.190 U

0.190 U

Sodium mg/L 18600 J

0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

Boron mg/L 8.90 0.0 U

0.01 U

0.010 U

0.01 U

0.01 U

0.01 U

Strontium mg/L 16.2 0.001 U

0.001 U

0.001 U

0.001 U

0.001 U

0.001 U

Bromide mg/L 138 J

0.0130 U

0.0130 U

0.0130 U

0.0130 U

0.0130 U

0.0130 U

Chloride mg/L 39000 J

0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

Fluoride mg/L 0.742 J-0.0240 U

0.0240 U

0.0240 U

0.0240 U

0.179 0.0240 U

Sulfate mg/L 5360 J

0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

Total Ammonia mg/L as N 0.0878 0.0260 U

0.0314 I

0.0260 U

0.0261 I

0.0262 I

Ammonium ion (NH4

+)

mg/L 0.0776 0.0319 Unionized NH3 mg/L 0.0334 0.00164 Nitrate/Nitrite mg/L as N 0.0270 U

0.0270 U

0.0270 U

0.00760 I

0.00540 U

0.00540 U

TKN mg/L 14.6 0.150 U

0.294 0.366 0.255 0.311 TN mg/L 14.63 0.32 ortho-Phosphate mg/L 0.00782 I

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

Total Phosphorus (P) mg/L 0.0535 0.00220 U

0.00220 U

0.00220 U

0.00220 U

0.00220 U

Alkalinity mg/L 126 J

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Bicarbonate Alkalinity mg/L as CaCO3 55.3 J

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 5.00 U

5.00 U

Salinity 62.7 J

Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 091013-DUP is a duplicate of TPSWC-1B.

Sample 091113-DUP2 is a duplicate of TPSWC-5B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

091213-FB1 09/12/2013 091013-FB1 090613-EB1 09/06/2013 TPSWCCS-7B 090913-FB1 09/09/2013 090513-FB1 09/05/2013 09/10/2013 091113-FB1 09/11/2013 09/05/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-40 Table 3.2-3. Summary of Surface Water Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 26.18 25.27 25.60 23.87 23.05 25.43 23.79 24.97 23.40 25.76 27.24 pH SU 7.99 7.94 7.71 7.39 7.18 7.65 7.32 7.91 7.52 7.19 6.89 Dissolved Oxygen mg/L 6.79 8.89 5.3 6.09 1.27 7.42 3.4 7.44 2.5 1.72 0.28 Specific Conductance S/cm 47355 47251 45990 648 778 619 639 636 1378 22129 28910 Turbidity NTU 1.15 0.54 0.55 0.85 1.24 0.38 0.64 0.68 3.36 1.08 7.36 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 9680 9550 9190 58.4 58.3 69.2 58.7 59.8 60.2 180 3800 5260 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 18200 18000 17300 115 115 139 119 120 122 364 7290 10400 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L Salinity 30.78 30.72 29.8 0.31 J

0.38 J

0.3 J

0.31 J

0.31 J

0.69 J

13.3 17.78 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

120513-DUP is a field duplicate of sample 120513-TPSWC-1T 121013-DUP is a field duplicate of sample 121013-TPSWCCS-5T KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

TPSWC-2B 12/5/2013 TPSWC-4T 12/10/2013 12/5/2013 12/5/2013 12/11/2013 TPSWC-3T TPSWC-3B TPBBSW-5B 12/5/2013 12/5/2013 TPSWC-4B TPSWC-1T TPBBSW-3B 12/11/2013 12/11/2013 12/5/2013 TPBBSW-4B 120513-Dup TPSWC-1B 12/5/2013 TPSWC-2T 12/10/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-41 Table 3.2-3. Summary of Surface Water Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 25.62 25.62 23.48 23.40 25.69 25.75 25.89 25.95 24.42 23.56 34.67 28.10 pH SU 7.86 7.75 7.21 7.27 7.78 7.78 7.55 7.18 7.63 7.68 8.13 8.2 Dissolved Oxygen mg/L 7.08 4.52 2.67 2.05 6.2 5.94 5.24 1.07 6.28 6.06 5.51 5.3 Specific Conductance S/cm 45693 47271 771 779 3289 3292 2718 3214 3947 5713 92911 87950 Turbidity NTU 0.51 0.41 0.29 0.23 0.4 0.27 0.22 1.24 6.34 0.18 61.99 56.87 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 9110 9260 54.6 57 464 465 370 444 571 888 19200 19200 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 18000 18200 97.8 101 859 833 736 865 1120 1740 41600 37000 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L Salinity 29.58 30.74 0.38 J

0.38 J

1.72 J

1.72 J

1.4 J

1.67 J

2.09 3.09 66.14 62.32 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

120513-DUP is a field duplicate of sample 120513-TPSWC-1T 121013-DUP is a field duplicate of sample 121013-TPSWCCS-5T KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

12/10/2013 12/2/2013 12/2/2013 12/10/2013 12/10/2013 12/10/2013 12/2/2013 TPSWC-5B 12/10/2013 TPSWID-3T TPSWC-6B TPSWCCS-1B TPSWID-3B TPSWID-2T TPSWC-6T TPSWCCS-2B TPSWC-5T 12/10/2013 TPSWID-2B TPSWID-1T TPSWID-1B 12/10/2013 12/6/2013 12/6/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-42 Table 3.2-3. Summary of Surface Water Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 30.98 29.15 28.67 34.84 pH SU 8.18 8.22 8.17 8.22 Dissolved Oxygen mg/L 6.15 6.12 4.93 7.66 Specific Conductance S/cm 90569 92534 92242 93266 J

Turbidity NTU 74.52 63.08 53.53 48.69 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 18400 19300 19600 19300 19600 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 38800 39800 38100 39700 45900 J

0.25 U

0.25 U

0.25 U

0.297 I

0.313 I

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 5

U 5

U 5

U 5

U 64 Salinity 64.38 66.14 65.91 66.77 J

Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

120513-DUP is a field duplicate of sample 120513-TPSWC-1T 121013-DUP is a field duplicate of sample 121013-TPSWCCS-5T KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

12/11/2013 12/02/2013 12/05/2013 12/06/2013 12/10/2013 12/10/2013 12/10/2013 41618 12/10/2013 12/10/2013 121113-FB1 121013-Dup 121013-FB1 TPSWCCS-7B TPSWCCS-5T TPSWCCS-3B TPSWCCS-4T 120213-EB1 120513-FB1 120613-FB1

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-43 Table 3.2-4. Summary of Surface Water Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 25.15 24.80 25.00 26.27 25.10 25.63 25.49 25.04 25.03 25.62 26.03 pH SU 8.35 8.21 8.19 8.03 7.63 8.34 8.14 8.23 8.18 7.62 7.63 Dissolved Oxygen mg/L 6.95 7.03 6.00 7.54 4.70 7.77 6.95 7.94 7.70 3.38 3.24 Specific Conductance S/cm 51939 51356 48399 771 785 913 911 1279 1296 16204 19942 Turbidity NTU 0.65 0.51 0.75 1.86 3.77 1.33 2.24 2.26 2.31 0.56 6.99 Silica, dissolved mg/L Calcium mg/L 426 418 413 386 66.5 68.6 72.1 74 85.5 85.8 86.9 224 244 Magnesium mg/L 1150 1130 1110 1030 10.7 10.8 10.2 10.6 15 15.2 15.3 300 374 Potassium mg/L 435 428 425 385 3.6 3.74 3.93 4.04 5.11 5.07 5.15 110 141 Sodium mg/L 10900 10700 10900 10100 74.9 76.9 98 97.9 146 150 151 2860 3580 Boron mg/L 4.75 4.76 4.69 4.21 0.0508 0.0528 0.0472 I

0.0486 I

0.0682 0.0582 0.0568 1.16 1.49 Strontium mg/L 7.73 7.63 7.49 6.95 0.617 0.627 0.763 0.778 0.888 0.885 0.896 3.19 3.64 Bromide mg/L 69.4 68.3 68.3 63 0.294 0.308 0.452 0.457 0.763 0.798 0.799 18.4 23.3 Chloride mg/L 19400 20200 19000 17500 139 141 185 183 290 301 302 5240 6560 Fluoride mg/L 0.867 0.871 0.889 0.85 J-0.0722 I

0.0713 I

0.0774 I

0.0777 I

0.0857 I

0.085 I

0.0777 I

0.333 0.403 Sulfate mg/L 2850 2770 2770 2550 8.03 J

8.91 J

13.1 13 24.3 19.6 19.6 681 881 Total Ammonia mg/L as N 0.163 J

0.111 J

0.0691 J

0.026 U

0.303 0.439 0.34 0.186 0.227 0.231 J

0.404 J

0.386 0.596 Ammonium ion (NH4

+)

mg/L 0.186 J

0.131 J

0.05 U

0.365 0.551 0.387 0.221 0.266 0.273 J

0.484 0.747 Unionized NH3 mg/L 0.0226 J

0.0112 J

1.7E-05 U

0.023 0.0127 0.0475 0.017 0.0244 0.0223 J

0.0113 0.0184 Nitrate/Nitrite mg/L as N 0.039 I

0.0478 I

0.027 U

0.027 U

0.0646 J

0.027 U

0.027 U

0.027 U

0.027 U

0.027 U

0.027 U

0.103 0.0996 TKN mg/L 0.554 0.544 0.536 0.533 0.701 0.871 0.702 0.815 0.686 0.757 0.672 1.05 0.952 TN mg/L 0.593 0.592 0.563 0.560 0.766 J

0.898 0.729 0.842 0.713 0.784 0.699 1.15 1.05 ortho-Phosphate mg/L 0.0117 J

0.0014 U

0.0014 U

0.0014 U

0.0019 I

0.0014 U

0.00241 I

0.00159 I

0.0014 U

0.00187 I

0.00258 I

0.0014 U

0.0014 U

Total Phosphorus (P) mg/L 0.0022 UJ 0.0022 U

0.0022 U

0.0113 I

0.0122 0.0103 0.0184 I

0.00443 I

0.00566 I

0.00565 I

0.00695 I

0.00283 I

0.003 I

Alkalinity mg/L 134 138 139 150 167 171 159 153 182 178 175 248 251 Bicarbonate Alkalinity mg/L as CaCO3 134 138 139 150 167 171 159 153 178 178 175 248 251 Sulfide mg/L 1

U Q 1

U Q 1

U Q 1

U Q 1

U 1

U 1

U 1

U 1

U 1

U 1

U 1

U 1

U Salinity 34.2 33.7 31.6 0.4 J

0.4 J

0.5 J

0.5 J

0.6 J

0.6 J

9.5 11.9 Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 031214-DUP is a duplicate of BBSW-4B.

Sample 030714-DUP2 is a duplicate of TPSWC-3B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL. pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

TPBBSW-5B TPSWC-1T 03/07/2014 03/12/2014 TPBBSW-3B 03/07/2014 03/07/2014 TPSWC-3B 03/07/2014 TPSWC-2T TPSWC-4B 03/04/2014 TPSWC-4T 03/04/2014 TPBBSW-4B 031214-DUP 03/12/2014 03/12/2014 TPSWC-2B 03/07/2014 03/12/2014 TPSWC-1B 03/07/2014 030714-DUP 03/07/2014 TPSWC-3T

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-44 Table 3.2-4. Summary of Surface Water Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 26.36 25.33 23.52 23.39 28.48 28.00 27.46 25.84 27.37 25.65 37.43 34.53 pH SU 7.85 7.96 7.32 7.27 7.60 6.90 7.28 7.22 7.46 7.35 8.42 8.79 Dissolved Oxygen mg/L 3.32 3.77 2.25 2.24 5.73 0.39 4.72 3.11 7.83 3.83 8.30 6.85 Specific Conductance S/cm 51652 51703 716 721 4851 10656 3226 3967 3304 3291 109243 107890 J

Turbidity NTU 0.28 1.03 0.27 0.37 0.75 39.79 0.53 1.09 0.51 0.44 106.30 93.91 Silica, dissolved mg/L 5.64 J

5.47 J

Calcium mg/L 429 425 77.6 78.9 147 186 139 151 141 138 1050 1020 J

Magnesium mg/L 1200 1200 8.55 8.73 82.5 186 48.2 61.2 47.8 46.2 2650 2440 J

Potassium mg/L 420 415 11 11.2 30.7 77 18.1 22.1 18.2 17.6 1000 1010 J

Sodium mg/L 10400 10500 50.1 51.5 710 1760 430 547 441 430 24500 24100 J

Boron mg/L 4.59 4.57 0.0785 0.0813 0.353 0.812 0.181 0.225 0.183 0.167 11.7 12 Strontium mg/L 7.6 7.5 0.973 0.983 1.71 2.52 1.52 1.71 1.49 1.44 21.2 21.2 Bromide mg/L 67.1 67.2 0.488 0.491 4.23 10.9 2.81 3.52 2.9 2.89 175 177 J

Chloride mg/L 19500 19300 89.1 92.5 1330 3270 827 1060 853 858 46000 48900 J

Fluoride mg/L 0.932 0.956 0.121 0.12 0.154 0.203 0.12 0.128 0.116 0.109 0.845 J

0.906 J

Sulfate mg/L 2780 2770 66.3 67.4 145 389 84.4 108 79.7 78.2 7740 7130 J

Total Ammonia mg/L as N 0.303 0.382 0.178 0.285 0.207 0.713 0.497 0.0272 I

0.18 0.275 0.152 J

0.234 J

Ammonium ion (NH4

+)

mg/L 0.373 0.466 0.226 0.363 0.259 0.912 0.631 0.05 U

0.227 0.349 0.145 J

0.18 J

Unionized NH3 mg/L 0.0156 0.0234 0.00229 0.00324 0.00706 0.0048 0.00768 0.000328 0.00416 0.0044 0.0476 J

0.114 J

Nitrate/Nitrite mg/L as N 0.0289 I

0.027 U

0.029 I

0.037 I

0.0816 J

0.0433 IJ 0.0835 J

0.132 J

0.202 J

0.168 J

0.0389 IJ 0.0445 IJ TKN mg/L 0.385 I

0.396 I

0.321 I

0.3 U

0.874 J

1.72 J

0.738 J

0.768 J

0.697 J

0.668 J

10.6 J

0.3 U

TN mg/L 0.414 0.423 0.350 0.337 0.956 J

1.76 J

0.822 J

0.900 J

0.899 J

0.836 J

10.6 J

0.340 J

ortho-Phosphate mg/L 0.0014 U

0.0014 U

0.00178 IJ 0.00211 IJ 0.0169 IJ 0.0166 IJ 0.014 UJ 0.014 UJ 0.014 UJ 0.014 UJ 0.014 U

0.0014 U

Total Phosphorus (P) mg/L 0.00368 I

0.00594 I

0.0022 U

0.0022 U

0.00689 IJ 0.0324 0.00229 IJ 0.00245 IJ 0.00229 IJ 0.00285 IJ 0.0583 0.00752 I

Alkalinity mg/L 153 147 161 158 344 448 280 298 264 271 151 146 J

Bicarbonate Alkalinity mg/L as CaCO3 153 147 161 158 344 448 280 298 264 271 54.3 19.3 J

Sulfide mg/L 1

U Q 1

U Q 1

U 1

U 1

U 4.5 1

U 1

U 1

U 1

U 1

U Q 1

U Q Salinity 33.9 34.0 0.4 J

0.4 J

2.6 6.0 1.7 J

2.1 1.7 J

1.7 J

80.1 79.1 J

Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 031214-DUP is a duplicate of BBSW-4B.

Sample 030714-DUP2 is a duplicate of TPSWC-3B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s). U = Analyzed for but not detected at the reported value.

TPSWID-3T TPSWC-6T 03/10/2014 TPSWID-1T TPSWC-6B 03/10/2014 03/04/2014 TPSWC-5B 03/04/2014 TPSWC-5T TPSWID-3B 03/03/2014 TPSWID-2T TPSWID-1B 03/03/2014 TPSWID-2B TPSWCCS-2B 03/03/2014 03/03/2014 03/03/2014 03/03/2014 TPSWCCS-1B 03/03/2014 03/05/2014

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-45 Table 3.2-4. Summary of Surface Water Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 32.26 29.23 29.22 36.76 pH SU 8.39 8.45 8.38 8.56 Dissolved Oxygen mg/L 8.79 7.54 8.75 12.30 Specific Conductance S/cm 101963 107858 J

107648 J

101912 Turbidity NTU 102.50 90.78 103.30 261.10 Silica, dissolved mg/L 5.33 J-5.67 J

5.49 J

5.44 J

0.05 U

0.05 U

0.05 U

0.05 U

0.05 U

Calcium mg/L 990 1050 J

1050 J

1010 0.1 U

0.1 U

0.1 U

0.1 U

0.1 U

Magnesium mg/L 2440 2640 J

2620 J

2510 0.02 U

0.02 U

0.02 U

0.02 U

0.02 U

Potassium mg/L 952 993 J

994 J

933 0.19 U

0.19 U

0.19 U

0.19 U

0.19 U

Sodium mg/L 23200 23600 J

23500 J

22400 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L 10.6 11.5 11.5 11.1 0.01 U

0.01 U

0.01 U

0.01 U

0.01 U

Strontium mg/L 20 21.2 20.9 20.3 0.001 U

0.001 U

0.001 U

0.001 U

0.001 U

Bromide mg/L 148 168 J

166 J

171 0.013 U

0.013 U

0.013 U

0.013 U

0.013 U

Chloride mg/L 41600 47800 J

48500 J

42300 0.25 U

0.476 I

0.364 I

0.25 U

0.25 U

Fluoride mg/L 0.814 J

0.838 J

0.841 J

0.821 J

0.024 U

0.024 U

0.024 U

0.024 U

0.024 U

Sulfate mg/L 6470 7290 J

7270 J

7300 0.766 0.25 U

1.11 0.304 I

0.250 U

Total Ammonia mg/L as N 0.114 J

0.132 J

0.0842 J

0.103 J

0.026 U

0.026 U

0.026 U

0.026 U

0.026 U

Ammonium ion (NH4

+)

mg/L 0.119 J

0.14 J

0.0915 J

0.0907 J

Unionized NH3 mg/L 0.0259 J

0.0284 J

0.0158 J

0.0394 J

Nitrate/Nitrite mg/L as N 0.027 UJ 0.0499 IJ 0.0416 IJI 0.0385 IJ 0.0331 I

0.027 U

0.0555 0.027 U

0.027 U

TKN mg/L 9.74 J

10.7 J

10.5 J

13.3 J

6.55 0.3 U

0.3 U

0.3 U

0.3 U

TN mg/L 9.77 J

10.7 J

10.5 J

13.3 J

ortho-Phosphate mg/L 0.014 U?

0.014 U

0.014 U

0.014 U

0.00325 I

0.00324 I

0.0014 U

0.00399 I

0.00293 I

Total Phosphorus (P) mg/L 0.0894 0.0282 0.0585 0.0425 0.0022 U

0.0022 U

0.0022 U

0.0022 U

0.0022 U

Alkalinity mg/L 158 150 J

147 J

169 1.41 1

U 1

U 1

U 1

U Bicarbonate Alkalinity mg/L as CaCO3 98.4 94.9 J

102 J

77 1.41 1

U 1

U 1

U 1

U Sulfide mg/L 1

U Q 1

U Q 1

U Q 1

U Q 1

U 1

U 1

U 1

U 1

U Salinity 74.0 79.4 J

79.3 J

73.7 Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 031214-DUP is a duplicate of BBSW-4B.

Sample 030714-DUP2 is a duplicate of TPSWC-3B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

031214-FB1 03/12/2014 TPSWCCS-7B TPSWCCS-3B 03/03/2014 030314-EB1 TPSWCCS-4T TPSWCCS-5T 03/03/2014 03/03/2014 03/03/2014 03/03/2014 030414-FB1 03/04/2014 030714-FB1 03/07/2014 031014-FB1 03/10/2014

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-46 Table 3.2-5. Range of Ion and Nutrient Concentrations in Surface Water Pre-Uprate Parameter Units Min Max Avg Stdev Min Max Avg Stdev Min Max Avg Stdev Min Max Avg Stdev Temperature

°C 24.80 29.47 27.08 1.88 17.02 31.91 26.50 5.20 23.56 32.30 28.02 2.37 23.48 31.97 28.15 2.86 pH SU 7.68 8.35 7.98 0.21 7.70 8.65 8.29 0.20 6.71 8.06 7.46 0.33 6.86 8.52 7.56 0.41 Dissolved Oxygen mg/L 4.21 8.89 5.89 1.32 4.00 9.22 6.50 1.64 0.39 7.83 4.47 2.17 0.04 7.44 3.10 2.54 Specific Conductance S/cm 45990 53783 49733 2682 30586 66855 50200 8419 2520 13700 4495 2615 2076 66251 14066 17711 Turbidity NTU 0.51 1.94 0.91 0.41 0.44 11.97 2.79 2.77 0.18 39.79 3.96 9.19 0.34 47.92 4.24 7.91 Calcium mg/L 386 426 407 15 260 540 423 63 100 195 138 30 87 610 211 138 Magnesium mg/L 1030 1150 1100 43 650 1700 1284 262 33 186 67 41 28 1700 310 447 Potassium mg/L 385 436 421 19 260 590 417 86 14 77 25 17 12 560 104 144 Sodium mg/L 8610 10900 9963 703 5400 14000 10349 2066 323 2300 659 462 290 14000 2577 3638 Boron mg/L 4.21 4.82 4.56 0.26 2.50 5.50 4.41 0.81 0.13 0.81 0.26 0.19 0.10 5.30 1.01 1.40 Strontium mg/L 6.95 7.73 7.28 0.32 4.30 9.90 7.47 1.35 1.18 2.52 1.55 0.42 1.00 11.00 2.96 2.60 Bromide mg/L 63.0 70.8 68.3 2.8 32.0 100.0 67.4 17.1 2.2 10.9 3.9 2.4 1.5 85.0 15.9 21.1 Chloride mg/L 17000 21300 19292 1609 11000 28000 19171 4119 660 4300 1279 855 110 27000 4790 6969 Fluoride mg/L 0.850 0.893 0.871 0.017 0.100 0.960 0.562 0.241 0.108 0.203 0.132 0.026 0.027 3.200 0.311 0.480 Sulfate mg/L 2550 2850 2683 118 1200 3700 2557 509 56 389 118 91 30 2900 520 714 Total Ammonia mg/L as N 0.0 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.7 0.3 0.2 0.2 1.9 0.5 0.5 Ammonium ion (NH4

+)

mg/L 0.0 0.2 0.1 0.1 0.0 0.2 0.1 0.0 0.1 0.9 0.3 0.3 0.2 2.4 0.6 0.6 Unionized NH3 mg/L 0.000017 0.0226 0.0075 0.0083 0.0039 0.0474 0.0176 0.0138 0.0003 0.0077 0.0040 0.0021 0.0025 0.0457 0.0174 0.0140 Nitrate/Nitrite mg/L as N 0.0054 0.0478 0.0222 0.0185 0.0047 0.0600 0.0235 0.0154 0.0270 0.2020 0.0742 0.0614 0.0047 0.1200 0.0316 0.0395 Total Kjedahl Nitrogen mg/L 0.5330 1.2800 0.8060 0.3104 0.1100 0.6300 0.3167 0.1194 0.6680 1.7200 0.9092 0.2892 0.7800 2.4000 1.1289 0.4467 Total Nitrogen mg/L 0.5600 1.2885 0.8282 0.2951 0.2500 0.6500 0.3500 0.1056 0.8091 1.7633 0.9834 0.2677 0.7883 2.4000 1.2028 0.4513 ortho-Phosphate mg/L 0.0014 0.0117 0.0031 0.0042 0.0014 0.0110 0.0041 0.0031 0.0014 0.0169 0.0082 0.0071 0.0014 0.0410 0.0172 0.0171 Total Phosphorus mg/L 0.0022 0.0113 0.0041 0.0036 0.0160 0.0520 0.0261 0.0144 0.0022 0.0324 0.0061 0.0086 0.0044 0.0400 0.0106 0.0096 Alkalinity mg/L 124 150 135 9

58 180 125 28 206 448 280 67 120 400 235 60 Bicarbonate Alkalinity mg/L as CaCO3 124 150 135 9

57 180 123 30 206 448 280 67 120 400 235 60 Sulfide mg/L 1.0 1.0 1.0 0.0 1.0 1.0 1.0 0.0 1.0 4.5 1.4 1.0 1.0 13.0 2.0 2.7 Total Dissolved Solids mg/L Salinity (PSS-78) 29.8 35.4 32.5 2.0 18.9 45.3 32.9 6.1 1.3 7.9 2.4 1.5 1.0 44.8 8.7 11.8 Tritium pCi/L (1)

NOTES:

  • PSS-78 salinity is unitless.

KEY:

°C = Degrees Celsius.

Min = Minimum.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

N = Nitrogen.

SU = Standard Unit(s).

= sigma (Standard Deviation).

NH3 = Ammonia.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH4

+ = Ammonium ion.

TN = Total nitrogen.

Max = Maximum.

NTU = Nephelometric Turbidity Units(s).

TPGW = Turkey Point Groundwater.

mg/L = Milligram(s) per liter.

Interceptor Ditch Biscayne Bay Post-Uprate Post-Uprate Pre-Uprate

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-47 Table 3.2-5. Range of Ion and Nutrient Concentrations in Surface Water Parameter Units Min Max Avg Stdev Min Max Avg Stdev Min Max Avg Stdev Min Max Avg Stdev Temperature

°C 23.05 30.71 26.59 2.18 19.64 33.11 27.65 3.72 28.10 40.33 33.77 3.46 19.43 40.31 30.26 5.61 pH SU 6.89 8.34 7.57 0.34 6.53 8.83 7.76 0.42 8.13 8.87 8.50 0.23 7.91 8.94 8.32 0.26 Dissolved Oxygen mg/L 0.19 7.94 4.05 2.25 0.22 9.44 4.56 2.51 4.28 12.30 6.52 1.83 2.05 8.08 5.39 1.49 Specific Conductance S/cm 402 55524 14173 20724 422 63421 15880 22785 74015 109243 90037 11519 68344 88902 80787 5067 Turbidity NTU 0.23 9.43 1.72 2.24 0.34 107.80 6.51 13.75 28.15 261.10 74.83 46.60 3.18 17.27 7.93 3.46 Calcium mg/L 50 443 163 147 44 560 189 175 778 1050 917 119 570 950 753 79 Magnesium mg/L 6

1200 288 461 6

1700 379 586 1920 2650 2272 303 1800 3000 2243 251 Potassium mg/L 2

437 108 169 3

540 126 190 769 1010 901 88 560 870 706 82 Sodium mg/L 31 11500 2715 4143 27 13000 3052 4668 15300 24500 19104 3022 15000 22000 17700 1645 Boron mg/L 0.04 4.59 1.14 1.79 0.03 5.70 1.29 1.97 8.32 12.00 10.09 1.43 6.20 11.00 7.61 0.85 Strontium mg/L 0.51 7.60 2.44 2.70 0.42 9.60 2.87 3.21 15.40 21.20 18.46 2.49 12.00 18.00 14.20 1.25 Bromide mg/L 0.2 72.5 17.5 27.9 0.0 110.0 20.8 33.1 127.0 177.0 150.8 19.0 52.0 270.0 118.1 28.1 Chloride mg/L 54 22900 5382 8236 39 28000 6089 9337 29800 48900 39008 5807 27000 39000 34114 2902 Fluoride mg/L 0.064 0.956 0.281 0.318 0.020 2.000 0.340 0.468 0.720 0.906 0.789 0.062 0.020 6.500 1.181 1.562 Sulfate mg/L 1

2780 676 1080 2

4000 783 1220 4990 7740 6208 1078 1300 5200 4270 732 Total Ammonia mg/L as N 0.0 0.6 0.2 0.1 0.1 0.4 0.2 0.1 0.1 0.2 0.1 0.0 0.1 0.5 0.2 0.1 Ammonium ion (NH4

+)

mg/L 0.0 0.7 0.3 0.2 0.1 0.5 0.2 0.1 0.07 0.2 0.1 0.0 0.1 0.7 0.2 0.1 Unionized NH3 mg/L 0.000017 0.0475 0.0113 0.0110 0.0026 0.0316 0.0109 0.0071 0.0158 0.1140 0.0408 0.0250 0.0000 0.0568 0.0245 0.0115 Nitrate/Nitrite mg/L as N 0.0060 0.1030 0.0311 0.0246 0.0047 0.5500 0.0813 0.1497 0.0270 0.0499 0.0346 0.0085 0.0047 0.1300 0.0377 0.0322 Total Kjedahl Nitrogen mg/L 0.3000 2.9200 0.8858 0.5293 0.4700 1.4000 0.9806 0.2890 9.7400 17.7000 13.2764 2.5258 1.5000 2.5000 2.0067 0.2935 Total Nitrogen mg/L 0.3370 2.9406 0.9169 0.5278 0.4700 1.6000 1.0589 0.3114 9.7670 17.7270 13.3101 2.5214 0.8700 3.0000 2.0541 0.4078 ortho-Phosphate mg/L 0.0014 0.0024 0.0015 0.0003 0.0014 0.0049 0.0021 0.0014 0.0014 0.0162 0.0099 0.0052 0.0014 0.0870 0.0137 0.0285 Total Phosphorus mg/L 0.0022 0.0184 0.0046 0.0040 0.0044 0.0420 0.0106 0.0108 0.0075 0.0894 0.0475 0.0206 0.0044 0.0730 0.0276 0.0167 Alkalinity mg/L 109 251 161 41 42 270 157 49 124 169 140 15 73 190 143 23 Bicarbonate Alkalinity mg/L as CaCO3 109 251 161 41 42 270 157 49 19 102 62 29 73 190 135 27 Sulfide mg/L 1.0 1.0 1.0 0.0 1.0 1.1 1.0 0.0 1.0 1.4 1.0 0.1 1.0 1.6 1.0 0.1 Total Dissolved Solids mg/L Salinity (PSS-78) 0.2 36.8 9.1 13.6 0.2 42.6 10.2 15.1 50.8 80.1 63.9 9.7 46.6 67.1 56.8 4.3 Tritium pCi/L (1)

NOTES:

  • PSS-78 salinity is unitless.

KEY:

°C = Degrees Celsius.

Min = Minimum.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

N = Nitrogen.

SU = Standard Unit(s).

= sigma (Standard Deviation).

NH3 = Ammonia.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH4

+ = Ammonium ion.

TN = Total nitrogen.

Max = Maximum.

NTU = Nephelometric Turbidity Units(s).

TPGW = Turkey Point Groundwater.

mg/L = Milligram(s) per liter.

Cooling Canals L-31E Post-Uprate Post-Uprate Pre-Uprate Pre-Uprate

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 FIGURES

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-49 Figure 3.1-1. Typical Groundwater Field Sampling Setup.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-50 Figure 3.1-2. Range (pre-Uprate) and Results (post-Uprate) of Quarterly Groundwater Samples for Chloride (mg/L).

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-51 Figure 3.1-3. Range (pre-Uprate) and Results (post-Uprate) of Quarterly Groundwater Samples for Sodium (mg/L).

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-52 Figure 3.1-4. Range (pre-Uprate) and Results (post-Uprate) of Quarterly Groundwater Samples for Specific Conductance

(µS/cm).

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-53 Figure 3.1-5. Locations of Aquifer Cross Sections for Groundwater Chloride Concentrations.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-54 Figure 3.1-6. Cross Section A-A Showing Quarterly Groundwater Chloride Concentrations from June/July 2010 through June 2014.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-55 Figure 3.1-7. Cross Section B-B Showing Quarterly Groundwater Chloride Concentrations from June/July 2010 through June 2014.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-1

3. QUARTERLY GROUNDWATER AND SURFACE WATER SAMPLING The Monitoring Plan (SFWMD 2009a) and the QAPP (FPL 2013b) for this project outline the locations and analytes for the groundwater and surface water sampling and the analyses for quarterly and semi-annual events. Each groundwater location is a cluster of three wells at different depth intervals. The groundwater wells are designated by depth and are defined as S for shallow wells (-15.3 to -34.7 ft North American Vertical Datum of 1988 [NAVD 88] to bottom of screen elevation), M for intermediate wells (-32.8 to -85.7 ft NAVD 88 to bottom of screen elevation), and D for deep wells (-46.4 to -122.2 ft NAVD 88 to bottom of screen elevation). Surface water samples are also designated by depth, i.e., T for top (1 ft below surface) and B for bottom (1 ft above bottom). Samples also were collected from several of the historical wells that have been monitored as part of the ID operations. Since the historical wells (L-3, L-5, G-21, G-28, and G-35) are screened across the entire well depth, samples were collected from two depths (18 ft and 58 ft below top of casing).

From June 2010 to May 2013, samples were collected quarterly at specified locations and were analyzed for the parameters as required in the Monitoring Plan. In June 2013, after review by the Agencies, several sites and parameters were dropped from the sampling. Three sites (TPBBSW-1B, TPBBSW-2B, and TPSWCCS-6 [B and T]) and two bottom stations (TPSWCCS-4B and TPSWCCS-5B) were eliminated. Per the Agencies, the data reductions (Tables 3.0-1 and 3.0-2) were as follows:

Trace metals analyses were eliminated for the Post-Uprate period.

Stable isotope (carbon (13C), oxygen (18O), hydrogen (D), and strontium(87Sr/86Sr))

analyses were eliminated for the Post-Uprate period.

Cation and anion analyses with the exception of sodium and chloride, were reduced from quarterly to semi-annually.

Sampling logs from June 2013 to March 2014 are provided in Appendix G. Most of the samples were analyzed by TestAmerica; however, tritium analysis was conducted by the USGS Tritium Laboratory. Details of the analytical methodologies for each analyte are provided in the project QAPP.

For the Post-Uprate, several analytical methods were changed because of interference that impacted result accuracy. For example, several ions have been problematic during analysis because of their low concentrations compared to the other peaks in the chromatogram. In the Post-Uprate, fluoride was switched to a probe analysis method due to frequent interference by the chloride peak. Sulfide was another method that was switched because of frequent non-detect values.

United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:

FLORIDA POWER & LIGHT COMPANY (Turkey Point Nuclear Generating, Units 3 and 4)

ASLBP #: 15-935-02-LA-BD01 Docket #: 05000250 & 05000251 Exhibit #:

Identified:

Admitted:

Withdrawn:

Rejected:

Stricken:

Other:

FPL-024E-00-BD01 1/4/2016 1/4/2016 FPL-024E

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-2 During the Post-Uprate, it was determined that bicarbonate alkalinity was being calculated as mg/L as CaCO3 instead of mg/L as HCO3 per the Monitoring Plan. This laboratory calculation affects all values after September 2010; therefore, a correction factor of x1.22 will have to be applied to datasets after September 2010 to adjust results to report as mg/L as HCO3 (TestAmerica 2014).

3.1 GROUNDWATER QUALITY 3.1.1 Sample Collection and Analysis Groundwater samples were collected in accordance with the QAPP and based on FDEP Standard Operating Procedures (SOPs). Figure 3.1-1 shows a typical setup for the groundwater sampling.

Groundwater and surface water sampling logs from June 2013 to March 2014 are included in Appendix G of this report.

3.1.2 Results and Discussion Values in most of the wells have been fairly consistent in the Post-Uprate period and are similar in range to values observed during the Pre-Uprate period. Tables 3.1-1 through 3.1-4 provide a summary of the groundwater analytical results from the June 2013 through May 2014 sampling events. Results for the sampling events from the historical monitoring wells L-3, L-5, G-21, G-28, and G-35 during the same time period are provided in Tables 3.1-5 through 3.1-8. DUS Reports for all events are provided in Appendix H, and the detailed Level IV laboratory reports from TestAmerica are included in Appendix I. A summary of the ionic ranges Pre-and Post-Uprate is provided in Table 3.1-9.

The only notable changes observed were in TPGW-10D and TPGW-7D, and to a lesser degree to TPGW-11D in this Post-Uprate period. Both TPGW-10D and TPGW-7D had higher specific conductance and ionic concentrations relative to the Pre-Uprate period; the ionic increases in TPGW-10D were observed starting in September 2012 during the Interim Operating Period while the increase in TPGW-7D started in September 2013. This is supported by automated monitoring specific conductance values as shown in Figures 2.1-8 and 2.1-11. A slight ionic and specific conductance increase was also observed in TPGW-11D starting in the Interim Operating Period. The more saline water at TPGW-10D and TPGW-11D remain confined at depth and do not appear to be migrating into the upwards. Further assessment of the water in TPGW-7D is pending as tritium data from June 2013 to March 2014 are still being analyzed by the USGS.

3.1.2.1 Chloride, Sodium, and Specific Conductance Figures 3.1-2, 3.1-3, and 3.1-4, and Tables 3.1-1 to 3.1-4 show the chloride, sodium, and specific conductance values for the sampling events from June 2013 through March 2014. There was some seasonal variation but lower than that observed in the surface waters. Within a well cluster, the lowest sodium and chloride values were generally observed in the shallow wells; the only exception to this was at TPGW-13 where the intermediate and deep wells had consistently lower

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-3 values than the shallow well over the monitoring period (Figures 3.1-2 and -3). The new monitoring wells, which were cased at specific intervals, also had lower variability compared to the historical monitoring wells, which are open throughout most of the well length.

Chloride values in TPGW-13 during the Post-Uprate period were similar to the values during the Pre-Uprate period (Table 3.1-9). Similarly, the ranges observed in the Biscayne Bay wells (TPGW-10, TPGW-11, and TPGW-14) showed the same Post-Uprate patterns with the exception of TPGW-10D and, to a lesser extent, TPGW-11D (Table 3.1-9). Both wells showed an increase in chloride concentrations commensurate with the specific conductance increase observed in the automated and other ionic data. During the Pre-Uprate period through February 2012, TPGW-10D chloride values were reflective of marine waters, but starting from September 2012 during the Interim Operating Period, this well now exhibits a mix of marine and some CCS water.

TPGW-11 during the Pre-Uprate had slightly higher chloride values in the intermediate and deep wells relative to the shallow well; the values in the intermediate well have not changed during the Post-Uprate, but chloride concentrations have been increasing in TPGW-11D starting in March 2013 during the Interim Operating Period and into the Post-Uprate.

Terrestrial wells around and to the west of the CCS (TPGW-1 through TPGW-6, TPGW-12, TPGW-L3, TPGW-L5, TPGW-G21, TPGW-G28, and TPGW-G35) had vertical and spatial Post-Uprate sodium, chloride, and specific conductance values similar to those observed during the Pre-Uprate period (Figures 3.1-5, 3.1-6, 3.1-7 and 3.1-8). The range of values observed in the shallow wells or 18 ft depth (in the case of the historical wells) continued to be lower than the samples from depth due to the fresher water lens that overlies the area west of the CCS. This freshwater zone is evident in the upper 20 to 40 ft of the aquifer and increases in depth towards the west; this is supported by the annual USGS induction log results (Appendix E) from the dry season (i.e., April 2014).

Temporally, the chloride, sodium, and specific conductance ranges across the landscape in the shallow wells were not significantly different in the four quarters of Post-Uprate compared to the seven Pre-Uprate events (chloride: F1,150=0.06, P=0.804; sodium: F1,150=0.47, P=0.504; specific conductance: F1,150=1.23, P=0.287). Wells TPGW-7, TPGW-8, and TPGW-9, farthest away from the CCS, were fresh (i.e., less than 500 milligrams per liter [mg/L] chloride and less than 1,275 µS/cm specific conductance) at all depths during the Pre-Uprate period and most of the wells remain fresh during the Post-Uprate. The only exception was TPGW-7D, which showed an increase in chloride, sodium, and specific conductance levels starting in September 2013.

Further assessment of the water in TPGW-7D cannot be conducted as tritium data from June 2013 onwards is still pending.

3.1.2.2 Ions Select ions (calcium, magnesium, potassium, boron, strontium, bromide, fluoride, and sulfate) analysis was reduced to semi-annually beginning in June 2013; sodium and chloride analyses were to continue on a quarterly basis. For the Post-Uprate period, data for both September 2013 and March 2014 are compared against the Pre-Uprate period (quarterly from June 2010 to December 2011). Ionic concentrations at the TPGW sites (Tables 3.1-1 to 3.1-4) appeared to

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-4 correspond with specific conductance values in most of the wells and varied seasonally, i.e.,

lower in the wet season (September 2013) and higher in the dry season (March 2014).

Tri-linear diagrams comparing the Post-Uprate to the Pre-Uprate indicated very little average difference in the overall patterns (Figure 3.1-9). Freshwater sites had low concentrations of ions, while marine-influenced sites generally had higher values. The highest values were observed at TPGW-13 (Table 3.1-9); the ionic chemistry of this site based on the tri-linear diagram showed that for both the Post-Uprate and Pre-Uprate, this station had similar chemistry (i.e., overlapping on the tri-linear diagram) to the marine stations (Figure 3.1-9). The range of values also remained consistent for most of the sites during the Post-Uprate period and Post-Uprate values were consistent with the Pre-Uprate values; the only exceptions were TPGW-7D, TPGW-10D and TPGW-11D which were higher, reflecting the increase in specific conductance observed.

TPGW-8S continues to have high pH (10.77 to 11.86) and high alkalinity (182 to 430 mg/L) in the Post-Uprate, similar to the Pre-Uprate period. The patterns are only observed at this depth at this location, and the alkalinity is mostly due to hydroxide ions indicating a stronger base than found under natural conditions.

3.1.2.4 Nutrients Tables 3.1-2 and 3.1-4 show the nutrient results for the September 2013 and March 2014 sampling events, while Figure 3.1-10 summarizes the data and compares it to the Pre-Uprate range. For the five groundwater sites monitored, nitrogen occurs primarily as ammonia (greater than 60% of total nitrogen [TN]) across the landscape at all depths. The majority (greater than 90%) of the ammonia was in the form of ammonium and this observation was consistent for both the Post-Uprate and Pre-Uprate periods.

Although TN was slightly higher in September 2013 relative to March 2014, both events were within range of the Pre-Uprate data. Nitrogen concentrations were lowest at TPGW-10 and TPGW-14, followed by TPGW-1, TPGW-2, and TPGW-13. Similar to specific conductance, wells at depth generally had higher nutrient concentrations compared to the shallower wells; the only exception was TPGW-13 where the nutrients in the shallow well were either similar to or higher than the wells at depth for both the Pre-and the Post-Uprate periods.

A one-time collection of nutrient data from TPGW-4 through TPGW-9 indicated that the wells were similar to the data from TPGW-10. Wells TPGW-5 and TPGW-7 showed a gradient of increasing TN with depth. TPGW-8S had high ammonia and unionized ammonia as pH>8 will increase the availability of ammonia. Consequently, this high ammonia contributes to high TKN that results in elevated TN. This result may be an artifact of the unusual chemistry of this site and not an influence from the CCS.

Although TP was slightly higher in September 2013 relative to March 2014, overall, average TP during the Post-Uprate (0.038 +/- 0.002 mg/L) in TPGW-13 was lower than in the Pre-Uprate (0.050 +/- 0.006 mg/L; F1,74=40.58; P<0.001). This Pre-Post Uprate trend was also observed in the other groundwater stations.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-5 3.2 SURFACE WATER QUALITY 3.2.1 Sample Collection and Analysis Surface water data were initially collected from 19 locations (33 sites), but this was reduced to 16 locations (27 sites) after Agency review in June 2013 (SFWMD 2013a). A list of the sites eliminated is shown in Section 1. The sampling methods follow Florida Department of Environmental Protection protocols and remain the same as described in the Comprehensive Pre-Uprate Report (FPL 2012); samples are still being collected from 1 ft below the surface (T) and 1 ft above the bottom (B) unless the water depths in the CCS, ID, or canals were less than 3 ft. In Biscayne Bay, regardless of water depth, all samples were collected at depth.

3.2.2 Results and Discussion Tables 3.2-1 through 3.2-4 provide a summary of the surface water analytical results from June 2013 through May 2014. DUS Reports for each event are provided in Appendix H and detailed Level IV laboratory reports from TestAmerica are included in Appendix I. Additionally, the stations have been grouped based on their general characteristics and location, and Table 3.2-5 shows the minimum, maximum, average and standard deviation of these water bodies from June 2013 to March 2014, unless otherwise explicitly stated.

3.2.2.1 Chloride, Sodium, and Specific Conductance Figures 3.2-1, 3.2-2, and 3.2-3 detail chloride, sodium, and specific conductance values for all surface water stations for the June 2013 through March 2014 sampling events. The values observed were highly dependent on the water body, water management practices, and seasonal conditions. Values were generally lower during the wet season and higher during the dry season.

Surface waters with chloride concentrations greater than 1,500 mg/L are defined as predominantly marine, while those with less than 1,500 mg/L are defined as predominantly fresh (F.A.C.62-302.200). The Class II/III criteria for specific conductance in freshwater (excluding consideration of background values) is less than 1,275 µS/cm while values higher than 1,275

µS/cm in a coastal environment are often viewed as potentially having some marine influence.

The highest chloride values were observed in the CCS (27,000 to 49,800 mg/L), with the highest values being observed in March 2014 and the lowest values in June 2013. The values observed during the Post-Uprate (average: 39,008 mg/L) were higher than the Pre-Uprate (average: 34,114 mg/L); however, none of the other surrounding water bodies showed a similar increase. Average chloride levels in other canals, as well as in Biscayne Bay, were lower in the Post-Uprate relative to the Pre-Uprate (which encompassed a drought in the spring of 2011).

Biscayne Bay values were influenced by rainfall, proximity to canal inputs, and water depth.

Consequently, TPBBSW-3 and TPBBSW-4 are more variable compared to TPBBSW-5, which is

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-6 farther south, in deeper water, and not near any inlets to allow exchange with the Atlantic Ocean.

The values in TPBBSW-4 are comparable to TPSWC-5, which is located in the Card Sound Canal, just south of the CCS. This station is connected to the Bay and values reflect the conditions in the Bay. Unlike the Pre-Uprate period where differences of up to 8,000 mg/L were observed between the top and bottom at this location, chloride differences during the Post-Uprate were limited (maximum difference of 1,400 mg/L higher at depth in June 2013).

TPSWC-1, TPSWC-2, TPSWC-3, and TPSWC-6 are all considered freshwater stations based on the average chloride, sodium, and specific conductance values for the Post-Uprate period.

However, during the dry season, the bottom of these stations can have slightly higher values of chloride and sodium compared to the surface. The sodium values during the Post-Uprate were however, lower than the Pre-Uprate values (F1,336=5.44; P=0.030) while the Post-Uprate chloride values were not significantly different than the Pre-Uprate (F1,335=0.94; P=0.342). The L-31E west of CCS is not a canal that is actively managed by the SFWMD; consequently, the values observed in TPSWC-1, TPSWC-2, and TPSWC-3 on this canal are primarily driven by rainfall and runoff from the Model Lands marsh. Sites at the top also tended to be fresher compared to depth. A similar pattern was observed at TPSWC-6 which is located on the Card Sound Road canal and is viewed as a control site for the CCS stations. Differences between the top and bottom sites were greatest at TPSWC-3, which was noticeably higher at the bottom relative to the top during December 2013.

Vertical differences were also observed at TPSWID-1, TPSWID-2, and TPSWID-3 during the Post-Uprate period. The chloride concentrations varied seasonally and also with pumping of the ID. The stations were fresh for most of the year (i.e., less than 1,500 mg/L chloride), but became saline at depth with pumping and limited rainfall. Concentrations would then slowly decline with the onset of the rains in the wet season. None of the values observed Post-Uprate, however, even approached the values observed during the 2011 drought that was part of the Pre-Uprate period.

Top and bottom station differences were also observed at TPSWC-4 even though this site is only about 5 ft deep. TPSWC-4 is located along the S-20 canal southwest of the CCS. In January 2014, a weir structure was installed downstream of this site, which resulted in a reduction of flow from the canal into Biscayne Bay. This resulted in a decrease in specific conductance, chloride, and salinity in March 2014 when there would normally have been an increase due to the dry season (as observed in the Pre-Uprate period).

3.2.2.2 Ions and Silica The seasonal and spatial ion concentrations (calcium, magnesium, potassium, boron, strontium, bromide, fluoride, and sulfate) in the surface water stations followed the observations noted above for sodium and chloride. Ion concentrations in the CCS were higher than those of Biscayne Bay (Table 3.2-5), while the TPSWC and TPSWID ions were generally lower in concentration but varied seasonally with freshwater influence.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-7 Ionic concentrations in the CCS during the Post-Uprate period were generally higher than during the Pre-Uprate years, but there were no differences between the Pre-and the Post-Uprate time periods for any of the other canals or Biscayne Bay. The values in the Bay were similar in range to the values observed by Reich et al. (2006). The tri-linear diagram (Figure 3.2-4) for the average Post-Uprate period showed clear separation between the different water bodies, with TPSWC-6 and the marine/CCS stations forming the endpoints along a spectrum of ionic concentrations. TPSWC-6 was distinct from the freshwater L-31E stations (TPSWC-1, TPSWC-2, and TPSWC-3) and the ID stations, but the marine-influenced (all TPBBSW, all TPSWCCS, TPSWC-4, and TPSWC-5) and CCS stations were ionically similar. These clusters remained consistent between the Post-and Pre-Uprate time periods.

During the Post-Uprate, silica was measured only in the CCS, twice a year at six of the seven original sites (TPSWCCS-6 eliminated). Silica concentrations in the Post-Uprate showed higher values in March 2014 compared to September 2013, and the Pre-Uprate period. Silica was 5.51

+/- 0.05 mg/L (average +/- standard error) in March 2014 but approximately half the concentration in September 2013 (2.65 +/- 0.03 mg/L); these values were also higher than the average (1.63 +/-

0.41 mg/L) observed during the Pre-Uprate period. These silica values are within the range observed by the FIU Water Quality monitoring network across Florida Bay (0.000 to 5.731 mg/L) and Biscayne Bay (0.000 to 1.972 mg/L) (Boyer and Briceno 2008).

3.2.2.3 Nutrients For all statistical analyses of CCS nutrients, all data from the CCS sites where surface water sampling was discontinued (TPSWCCS-4B, -5B, -6T, and -6B) were removed from the analyses.

Figure 3.2-5 shows the distribution of nutrient concentration in the surface water for September 2013 and March 2014. The most notable change was the increase in the TN within the CCS in the Post-Uprate period compared to the Pre-Uprate period (F1,28=311.44; P<0.001). As almost all the TN in the monitoring stations was from TKN, this change was attributable to the increase of TKN in the Post-Uprate period (13.28 +/- 0.76 mg/L) compared to the Pre-Uprate period (2.01

+/- 0.05 mg/L) in the CCS (Figure 3.2-6). TKN is sum of ammonia and organic nitrogen (amino acids, urea). These increases in the CCS are from an increase in organic nitrogen sources as the ammonia contribution to the TKN of these samples were only about 1% for both sampling events. Although TKN values were approximately 15 mg/L in the CCS in September 2013, these values had decreased approximately 30% to about 11 mg/L by March 2014.

In the other water bodies, ammonia contribution varied seasonally (i.e., lower in September 2013 relative to March 2014), as well as spatially (the Bay was less than the surface water canal or the ID sites). Ammonia values in the ID and the surface water canals were higher than both the CCS or in Biscayne Bay. This is not unexpected as these canals have biological activity and limited turnover of water most of the year (Figure 3.2-6). The Post-Uprate ammonia patterns were consistent with the Pre-Uprate values (Table 3.2-5), indicating little temporal variability.

Similarly, the patterns of the other nitrogen species (i.e., nitrate/nitrite, unionized ammonia, ammonium) did not vary between the Pre-and Post-Uprate either.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-8 Total phosphorus is higher in the Post-Uprate (0.048 +/- 0.006 mg/L) compared to the Pre-Uprate (0.028 +/- 0.003 mg/L) within the CCS (F1,29=6.73; P=0.050). These differences are not unexpected given the increase in TN between the same time periods. Both TN and TP are key biological nutrients so an increase in TN is often accompanied by an increase in TP (Quiros 2002). Values in the other water bodies however remained consistent and did not show a similar Pre-Post Uprate increase over the monitoring duration.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 TABLES

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-10 Table 3.0-1. Groundwater and Surface Water Sampling Locations and Events Event Locations Source Category1 Quarterly TPGW-1, -2, -3, -4, -5, -6, -7, -8, -9, -10, -

11, -12, -13, -14; L-3, -5; G-21, -28, -35 GW TPBBSW - 1, 2, 3, 4, 5 TPSWC - 1, 2, 3, 4, 5, 6 TPSWID - 1, 2, 3 SW TPSWCCS - 1, 2, 3, 4, 5, 6, 7 CCS Semi-annual TPGW-3, 4, 5, 6, 7, 8, 9, 11, 13, L-3, L-5, G-21, G-28, G-35 GW TPGW - 1, 2, 10, 13, 14 GW - quarterly analytes plus nutrients TPBBSW - 1, 2, 3, 4, 5 TPSWC - 1, 2, 3, 4, 5, 6 TPSWID - 1, 2, 3 SW - quarterly analytes plus nutrients TPSWCCS - 1, 2, 3, 4, 5, 6, 7 CCS - quarterly analytes plus nutrients Notes:

1 = Analytes from Table 3.0-2 plus field parameters (temperature, specific conductivity, DO, percent oxygen saturation, pH, ORP, and salinity) at all stations.

Key:

CCS - Cooling Canal System.

GW - Groundwater.

ORP = Oxidation reduction potential.

SW - Surface Water.

TPBBSW - Biscayne Bay Surface Water.

TPGW - Turkey Point Groundwater.

TPSWC - Turkey Point Surface Water Canal.

TPSWID - Turkey Point Surface Water Interceptor Ditch.

TPSWCCS - Turkey Point Surface Water Cooling Canal System.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-11 Table 3.0-2.

Analytes Measured in Groundwater, Surface Water, and the Cooling Canal System Analyte Monitoring Plan (Table 2-1) Label GW SW CCS Chloride (Cl-)

Ions Q

Q Q

Sodium (Na+)

Q Q

Q Other Anions (SO4 2-, F-, Br-)

Ions SA SA SA Other Cations (Ca2+, Mg2+, K+, Sr2+, B+)

Ions SA SA SA Alkalinity Ions SA SA SA Ammonia + unionized Nutrients SA SA SA Nitrate/Nitrite Nutrients SA SA SA Total Kjeldahl Nitrogen Nutrients SA SA SA Total Phosphorus Nutrients SA SA SA Soluble Reactive Phosphorus Nutrients SA SA SA Silica Nutrients SA Sulfides Ions SA SA SA TDS Other Q

Key:

Q = Quarterly event.

SA = Semi-annual event.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-12 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 25.75 25.76 25.88 26.22 26.78 26.74 26.08 26.19 25.97 25.4 25.37 25.23 24.11 24.13 24.11 pH SU 6.97 7.07 6.91 7.2 6.84 6.94 6.49 6.83 6.74 6.87 7.02 6.86 7.01 6.79 6.95 Dissolved Oxygen mg/L 0.21 0.36 0.43 0.23 J

0.28 J

0.56 J

0.88 0.36 1.09 0.6 0.64 0.74 0.39 0.73 1.19 Specific Conductance S/cm 54661 72371 72253 69081 75789 77111 64740 69067 69917 J

1670 39169 43372 1134 32517 34844 Turbidity NTU 0.35 0.01 0.1 0.69 0.13 0.08 0.04 0.32 0.3 0.39 0.14 0.16 0.1 0.19 0.22 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 10900 15200 15300 16800 18900 18600 13400 14500 14700 178 7540 8800 100 6340 6650 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 20500 29800 29900 27700 30900 30000 27300 29300 33000 J

342 13800 16400 204 12100 12700 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N 0.783 0.585 0.497 0.19 J

0.562 0.558 Ammonium ion (NH4

+)

mg/L 1.00 0.748 0.636 0.243 0.72 0.714 Unionized NH3 mg/L 0.004 0.004 0.003 0.001 0.002 0.003 Nitrate/Nitrite mg/L as N 0.005 U

0.005 U

0.005 U

0.005 U

0.005 U

0.005 U

TKN mg/L 1.28 1.13 0.903 0.519 0.829 0.843 TN mg/L 1.29 1.14 0.908 0.524 0.834 0.848 ortho-Phosphate mg/L 0.061 J

0.035 J

0.033 J

0.038 0.042 J

0.039 J

Total Phosphorus (P) mg/L 0.002 UJ 0.021 J

0.027 J

0.004 I

0.02 J

0.012 J

Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 34300 50000 48300 43300 47400 49300 42500 45300 47500 850 21300 25900 613 20800 20800 Salinity 36.17 49.78 49.68 47.6 52.47 53.53 43.8 47.17 47.84 J

0.84 J

24.93 27.92 0.56 J

20.37 21.92 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/4/2013 6/7/2013 6/11/2013 6/11/2013 6/11/2013 6/7/2013 6/6/2013 6/6/2013 6/6/2013 6/6/2013 6/7/2013 6/4/2013 6/4/2013 6/6/2013 6/6/2013 TPGW-1M TPGW-1D TPGW-4D TPGW-4M TPGW-4S TPGW-2D TPGW-2M TPGW-5D TPGW-3D TPGW-1S TPGW-5M TPGW-5S TPGW-2S TPGW-3M TPGW-3S

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-13 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 23.84 24.04 24.35 24.26 24.44 24.43 24.36 24.1 24.26 25.04 24.47 24.39 pH SU 6.94 7.02 6.83 6.99 6.96 7.04 11.66 6.99 6.88 6.75 6.71 6.89 Dissolved Oxygen mg/L 1.13 0.85 0.23 0.2 0.5 0.32 0.74 0.81 0.25 0.28 0.74 1.2 Specific Conductance S/cm 1107 22767 23691 546 559 599 1178 642 677 605 625 642 Turbidity NTU 0.98 0.01 1.42 0.95 0.09 0.31 0.35 0.02 0.7 0.12 0.22 0.24 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 88.7 4130 4090 4280 19 19.8 25.6 19.1 18 25.3 10.9 11.8 15.5 15.3 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 178 7830 8050 8270 34.8 34.1 43.2 34.9 43.8 44.6 19.5 20 27.1 25.2 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N 0.313 0.508 0.525 0.584 0.103 0.129 0.087 0.179 0.139 0.141 0.353 0.305 0.368 0.398 Ammonium ion (NH4

+)

mg/L 0.401 0.65 0.748 0.132 0.165 0.111 0.03 U

0.178 0.181 0.452 0.391 0.471 Unionized NH3 mg/L 0.002 0.003 0.003 7E-04 8E-04 6E-04 0.216 9E-04 7E-04 0.001 0.001 0.002 Nitrate/Nitrite mg/L as N 0.005 U

0.005 U

0.0054 U

0.005 U

0.01 0.006 I

0.014 0.007 I

0.005 U

0.016 0.009 I

0.014 0.024 0.0054 U

TKN mg/L 0.849 0.523 J

0.767 J

0.712 0.973 1.24 3.43 11.8 0.326 0.471 0.81 0.678 0.793 0.754 TN mg/L 0.854 0.528 0.717 0.983 1.25 3.44 11.8 0.331 0.487 0.819 0.692 0.817 ortho-Phosphate mg/L 0.054 J

0.037 J

0.0365 0.038 J

0.001 U

0.002 I

0.002 I

0.001 U

0.001 I

0.002 I

0.007 I

0.005 I

0.001 U

0.0014 U

Total Phosphorus (P) mg/L 0.003 IJ 0.013 J

0.0126 0.013 J

0.006 I

0.007 I

0.007 I

0.004 U

0.01 I

0.011 I

0.013 I

0.038 0.014 I

0.0022 U

Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 540 12800 13700 13900 264 296 304 280 J

332 352 300 332 332 340 Salinity 0.55 J

13.74 14.35 0.26 J

0.27 J

0.29 J

0.58 J

0.31 J

0.33 J

0.29 J

0.3 J

0.31 J

Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/6/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/6/2013 6/6/2013 6/6/2013 6/5/2013 TPGW-9M TPGW-9S TPGW-7S TPGW-8D TPGW-8M TPGW-8S TPGW-9D TPGW-6S 060513-DUP1 TPGW-7D TPGW-7M TPGW-6D TPGW-6M 6/5/2013 060613-DUP1

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-14 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 26.58 26.61 26.29 25.94 26.08 26.27 26.21 26.33 26.19 29.57 29.19 29.44 pH SU 7.53 7.48 6.69 6.79 6.58 6.74 6.51 6.81 7.14 6.73 6.84 6.86 Dissolved Oxygen mg/L 0.3 0.25 0.34 0.08 0.05 0.2 0.67 0.44 0.16 0.33 0.24 0.66 Specific Conductance S/cm 52399 55198 65776 54830 56758 61576 45468 63156 65782 83609 79528 80552 Turbidity NTU 0.27 0.23 0.29 0.4 0.44 0.41 0.4 0.3 0.38 0.11 0.12 0.26 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 10700 11600 13700 11400 11800 12900 8970 12800 13300 18100 17000 17100 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 23200 23800 29000 24300 23000 25700 16800 24700 25100 39800 37200 36600 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 37000 37300 43500 36100 37200 41900 27100 41600 43300 58500 55600 55400 Salinity 34.47 36.55 44.6 36.29 37.74 41.38 29.41 42.58 44.61 58.69 55.38 56.21 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/11/2013 6/11/2013 6/11/2013 TPGW-13D 6/13/2013 6/13/2013 6/13/2013 6/4/2013 TPGW-12S TPGW-12D 6/4/2013 TPGW-12M 6/4/2013 TPGW-11M TPGW-11S TPGW-10M TPGW-10S TPGW-13M TPGW-11D TPGW-10D TPGW-13S 6/12/2013 6/12/2013 6/12/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-15 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units RER Temperature

°C N26.77 27.18 27.3 pH SU N 6.73 6.78 6.68 Dissolved Oxygen mg/L N 0.13 0.2 0.27 Specific Conductance S/cm N57630 63204 73522 Turbidity NTU N 0.04 0.4 0.06 Silica, dissolved mg/L N

Calcium mg/L N

Magnesium mg/L N

Potassium mg/L N

Sodium mg/L N11900 12500 13100 15900 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L N

Strontium mg/L N

Bromide mg/L N

Chloride mg/L N24400 24600 27700 32900 0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

Fluoride mg/L 1

Sulfate mg/L N

Total Ammonia mg/L as N 0.026 U

0.0309 I

Ammonium ion (NH4

+)

mg/L N

Unionized NH3 mg/L N

Nitrate/Nitrite mg/L as N N

0.0054 U

0.0054 U

TKN mg/L N

0.236 0.15 U

TN mg/L N

ortho-Phosphate mg/L N

0.0014 U

0.0014 U

Total Phosphorus (P) mg/L N

0.0022 U

0.0022 U

Alkalinity mg/L N

Bicarbonate Alkalinity mg/L as CaCO3 N Sulfide mg/L Total Dissolved Solids mg/L N38900 38000 43200 51600 5

U 5

U 5

U 5

U 5

U Salinity 38.37 42.59 50.64 Tritium pCi/L N

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/10/2013 061113-EB1 6/6/2013 6/5/2013 6/11/2013 060413-FB1 060513-FB1 TPGW-14D TPGW-14M TPGW-14S 061213-DUP1 061213-FB1 6/4/2013 060613-FB1 061013-FB1 6/12/2013 6/12/2013 6/12/2013 6/12/2013 6/12/2013 060713-FB1 061313-FB1 6/7/2013 6/13/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-16 Table 3.1-1. Summary of Groundwater Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 26.77 27.18 27.3 pH SU 6.73 6.78 6.68 Dissolved Oxygen mg/L 0.13 0.2 0.27 Specific Conductance S/cm 57630 63204 73522 Turbidity NTU 0.04 0.4 0.06 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 11900 12500 13100 15900 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 24400 24600 27700 32900 0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N 0.026 U

0.0309 I

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.0054 U

0.0054 U

TKN mg/L 0.236 0.15 U

TN mg/L ortho-Phosphate mg/L 0.0014 U

0.0014 U

Total Phosphorus (P) mg/L 0.0022 U

0.0022 U

Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 38900 38000 43200 51600 5

U 5

U 5

U 5

U 5

U Salinity 38.37 42.59 50.64 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

Sample 061213-DUP1 is a duplicate of 061213-TPGW-14S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

6/10/2013 061113-EB1 6/6/2013 6/5/2013 6/11/2013 060413-FB1 060513-FB1 TPGW-14D TPGW-14M TPGW-14S 061213-DUP1 061213-FB1 6/4/2013 060613-FB1 061013-FB1 6/12/2013 6/12/2013 6/12/2013 6/12/2013 6/12/2013 060713-FB1 061313-FB1 6/7/2013 6/13/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-17 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 26.68 26.74 27.10 26.08 26.48 26.77 26.70 26.61 26.79 pH SU 6.99 6.94 6.99 7.12 6.89 6.74 6.63 6.90 6.77 Dissolved Oxygen mg/L 0.33 0.40 1.07 0.10 0.09 0.95 J

0.20 0.19 1.93 J

Specific Conductance S/cm 34093 72181 70477 66453 75066 77475 63967 67890 70817 Turbidity NTU 0.45 0.29 0.24 0.79 0.11 0.09 0.07 0.11 0.28 Silica, dissolved mg/L Calcium mg/L 411 644 653 1080 J

669 J

667 673 653 624 639 Magnesium mg/L 726 1610 J-1650 J-1210 J

1680 J

1690 1730 1460 1550 1590 Potassium mg/L 241 592 J+

614 J+

527 J

614 J

613 628 509 558 569 Sodium mg/L 6290 14700 14300 13900 J

15900 J

15800 16200 13300 14300 14300 Boron mg/L 2.29 5.83 5.81 5.24 6.33 6.35 6.46 5.05 5.7 5.83 Strontium mg/L 6.09 10.8 11.1 13.2 13.5 13.6 13.4 10.8 11.8 11.9 Bromide mg/L 45.2 J

92.5 101 J

94.8 J

107 J

108 111 J

91.8 96.5 98.3 Chloride mg/L 13500 J

28800 31300 J

28100 J

31800 J

32000 33500 J

27100 28800 29400 Fluoride mg/L 0.198 J

0.233 J-0.251 J-0.173 J

0.231 J

0.234 J

0.221 J

0.0240 U

0.182 J

0.183 J

Sulfate mg/L 1570 J

3660 3880 J

3340 J

3900 J

3910 4050 J

3400 3550 3650 Total Ammonia mg/L as N 0.948 1.60 1.55 1.57 1.93 1.86 1.85 Ammonium ion (NH4

+)

mg/L 1.21 2.05 1.98 2.00 2.47 2.37 Unionized NH3 mg/L 0.00716 0.0108 0.0121 0.0153 0.0114 0.00793 Nitrate/Nitrite mg/L as N 0.0270 U

0.0280 I

0.0270 U

0.0270 U

0.0299 0.0227 0.0270 U

TKN mg/L 1.73 J

2.65 J

2.75 J

2.62 2.64 2.61 3.16 TN mg/L 1.76 J

2.68 J

2.78 J

2.65 2.67 2.63 3.19 ortho-Phosphate mg/L 0.0222 0.00340 I

0.0447 J

0.0104 0.0358 J

0.0356 0.0343 J

Total Phosphorus (P) mg/L 0.0282 0.0346 0.0346 J

0.0131 0.0204 J

0.0218 0.0169 J

Alkalinity mg/L 291 J

183 183 J

103 J

194 J

194 193 J

406 234 224 Bicarbonate Alkalinity mg/L as CaCO3 291 J

183 183 J

103 J

194 J

194 193 J

406 234 224 Sulfide mg/L 1.46 1.00 U

1.38 1.24 1.01 1.09 1.01 11.0 1.17 1.63 Total Dissolved Solids mg/L 20900 49800 49000 43200 53600 51400 51800 41100 44700 45200 Dissolved Inorganic Carbon mg/L Salinity 21.35 49.6 48.24 45.13 51.9 53.82 43.2 46.23 48.51 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 090413-DUP1 is a duplicate of TPGW-8M.

Sample 091113-DUP1 is a duplicate of TPGW-2M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

091113-DUP 09/06/2013 09/06/2013 09/06/2013 09/11/2013 09/11/2013 09/11/2013 09/11/2013 09/11/2013 09/11/2013 09/11/2013 TPGW-1D TPGW-1M TPGW-3S TPGW-3D TPGW-3M TPGW-2D TPGW-2M TPGW-2S TPGW-1S

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-18 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 25.60 25.22 25.32 25.17 24.92 25.04 24.44 24.35 24.71 24.61 24.49 24.56 pH SU 6.65 6.94 7.16 6.64 6.99 6.75 6.87 6.69 6.95 6.96 6.90 Dissolved Oxygen mg/L 0.47 1.26 J

0.84 0.75 J

1.20 0.93 J

0.46 0.33 J

0.30 0.28 0.20 1.05 Specific Conductance S/cm 1815 39421 43517 1028 33043 35014 1182 22893 23830 539 553 738 Turbidity NTU 0.30 0.53 0.39 0.47 0.40 0.34 0.10 0.53 0.10 1.99 0.00 J

0.44 Silica, dissolved mg/L Calcium mg/L 139 591 J-584 J-109 609 J-580 J-119 497 J-507 J-79.0 82.6 95.1 Magnesium mg/L 18.6 784 890 7.08 646 664 11.5 403 419 3.87 3.91 4.41 Potassium mg/L 4.04 200 269 5.74 150 173 4.69 102 106 7.49 7.19 5.27 Sodium mg/L 189 7080 J-8130 80.6 5910 J-6170 J-99.5 3790 J-3970 J-18.4 19.7 38.4 Boron mg/L 0.0667 1.42 2.11 0.0497 I

1.02 1.25 0.0605 0.789 0.813 0.0446 I

0.0489 I

0.0602 Strontium mg/L 1.3 7.44 7.84 1.08 7.08 7.21 1.2 7.75 7.88 0.785 0.818 0.934 Bromide mg/L 1.30 46.6 55.1 0.584 37.9 44.1 0.727 26.5 27.7 0.147 0.152 0.348 Chloride mg/L 400 15500 17600 170 13100 13700 208 8120 8980 35.0 36.4 90.8 Fluoride mg/L 0.0900 I

0.125 0.131 0.112 0.119 0.128 0.120 0.133 0.133 0.118 0.114 0.112 Sulfate mg/L 9.40 1690 1990 16.9 1340 1480 8.87 825 872 22.1 23.7 25.7 Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L 332 212 203 244 228 222 282 210 217 199 203 201 Bicarbonate Alkalinity mg/L as CaCO3 332 212 203 244 228 222 282 210 217 199 203 201 Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.30 1.00 U

1.77 1.38 1.06 1.22 Total Dissolved Solids mg/L 900 24000 27300 507 19900 20500 607 13900 14000 276 284 408 Dissolved Inorganic Carbon mg/L Salinity 0.9 J

25.1 28.0 0.51 J

20.7 22.0 0.59 J

13.82 14.43 0.26 J

0.27 J

0.36 J

Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 090413-DUP1 is a duplicate of TPGW-8M.

Sample 091113-DUP1 is a duplicate of TPGW-2M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

09/03/2013 09/03/2013 09/04/2013 09/04/2013 09/04/2013 09/03/2013 09/03/2013 TPGW-7M TPGW-7S 09/03/2013 TPGW-4S TPGW-6D TPGW-6M TPGW-6S TPGW-5M TPGW-5S TPGW-7D 09/03/2013 TPGW-5D 09/03/2013 09/03/2013 TPGW-4M TPGW-4D 09/03/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-19 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 24.84 25.01 25.25 26.10 25.78 25.65 27.48 27.46 27.23 pH SU 10.77 J

6.78 6.78 6.66 6.68 6.65 7.31 7.32 6.97 Dissolved Oxygen mg/L 1.48 0.56 0.18 0.50 0.45 0.39 0.25 0.12 0.62 J

Specific Conductance S/cm 1139 J

642 681 594 639 644 51928 54309 66489 Turbidity NTU 0.23 0.10 0.96 2.31 0.54 0.09 0.17 0.08 0.14 Silica, dissolved mg/L Calcium mg/L 102 102 102 101 114 117 111 506 506 649 Magnesium mg/L 0.564 3.74 3.69 5.93 2.51 3.15 3.61 1400 J-1390 J-1740 J-Potassium mg/L 9.55 9.94 9.71 8.92 4.20 6.64 3.87 486 503 626 Sodium mg/L 18.3 17.3 17.0 26.6 8.05 12.3 15.2 12000 J-11900 J-15200 J-Boron mg/L 0.043 I

0.065 0.064 0.0786 0.0346 I

0.0492 I

0.0528 5.12 5.27 6.32 Strontium mg/L 0.576 1.03 1.01 1.05 0.811 0.968 1.14 8.83 9.43 11.8 Bromide mg/L 0.211 0.215 0.216 0.251 0.151 0.248 0.369 71.6 75.4 91.7 Chloride mg/L 34.0 32.6 32.9 45.6 15.8 22.5 28.0 21100 22400 26900 Fluoride mg/L 0.0813 I

0.0947 I

0.0939 I

0.103 0.0885 I

0.0870 I

0.0908 I

0.748 J-0.585 J-0.250 J-Sulfate mg/L 46.7 58.7 58.5 53.9 3.09 18.1 29.7 2760 2880 3400 Total Ammonia mg/L as N 0.413 0.298 0.796 Ammonium ion (NH4

+)

mg/L 0.524 0.378 1.02 Unionized NH3 mg/L 0.00684 0.00504 0.00597 Nitrate/Nitrite mg/L as N 0.128 0.00540 U

0.00998 I

TKN mg/L 0.741 J

0.762 J

1.17 J

TN mg/L 0.87 J

0.77 J

1.18 J

ortho-Phosphate mg/L 0.0222 J

0.0206 J

0.0400 J

Total Phosphorus (P) mg/L 0.00907 I J 0.00601 I J 0.0135 J

Alkalinity mg/L 182 226 223 227 286 284 266 130 117 157 Bicarbonate Alkalinity mg/L as CaCO3 1.00 U

226 223 227 286 284 266 130 117 157 Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.26 1.00 U

1.00 U

5.06 1.51 3.75 Total Dissolved Solids mg/L 307 J

356 344 368 308 332 348 38100 41300 46900 Dissolved Inorganic Carbon mg/L Salinity 0.56 J

0.31 J

0.33 J

0.29 J

0.31 J

0.31 J

34.07 35.86 45.13 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

09/12/2013 09/12/2013 09/12/2013 09/04/2013 09/04/2013 09/04/2013 09/04/2013 09/04/2013 09/04/2013 09/04/2013 TPGW-8D TPGW-8M TPGW-8S 090413-DUP TPGW-10S TPGW-9D TPGW-9M TPGW-9S TPGW-10D TPGW-10M

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-20 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 27.19 27.24 26.71 27.05 27.38 27.43 29.53 29.27 29.58 27.36 27.37 27.40 pH SU 6.96 6.60 6.82 6.57 6.81 7.20 6.77 6.85 6.84 6.92 6.83 6.70 Dissolved Oxygen mg/L 0.46 0.75 J

0.61 0.11 0.13 0.26 0.02 0.32 0.13 0.19 0.03 1.10 J

Specific Conductance S/cm 54061 58157 59926 43559 65648 64449 83887 78994 80613 57102 61790 75201 Turbidity NTU 0.16 0.00 J

0.26 0.54 0.41 1.19 1.07 0.05 0.03 0.06 0.50 0.21 Silica, dissolved mg/L Calcium mg/L 545 596 622 501 616 605 758 J

693 722 547 662 671 Magnesium mg/L 1360 J-1390 J-1470 J-968 1480 J-1430 J-2010 J-1720 J-1850 J-1370 J-1590 J-1790 J-Potassium mg/L 500 498 526 330 526 J+

523 J+

753 J+

702 J+

683 J+

484 601 652 Sodium mg/L 11900 J-12500 J-13200 J-8310 12600 13000 17700 J

16500 16500 12100 J-14500 J-15500 J-Boron mg/L 5.5 5.44 5.38 3.36 4.95 4.98 7.55 6.89 6.98 5.09 6.15 6.57 Strontium mg/L 9.33 9.84 10.7 6.89 9.89 9.85 13.9 14.2 13.4 9.34 11.9 13.1 Bromide mg/L 75.5 78.1 84.7 55.7 85.0 89.9 122 J

113 J

116 J

79.0 84.7 108 J

Chloride mg/L 22300 23300 25400 17600 28300 27800 37300 J

34700 J

36400 J

23500 25100 32900 J

Fluoride mg/L 0.780 J-0.531 J-0.600 J-0.395 0.243 J-0.239 J-0.354 J-0.193 J-0.212 J-0.484 J-0.409 J-0.377 V J-Sulfate mg/L 2890 2920 3140 2170 3550 3500 4820 J

4120 J

4580 J

2980 3160 3900 J

Total Ammonia mg/L as N 2.59 1.45 J+

1.73 0.479 0.972 2.08 Ammonium ion (NH4

+)

mg/L 3.31 1.85 J+

2.21 0.612 1.24 2.67 Unionized NH3 mg/L 0.0144 0.00950 J+

0.0113 0.00323 0.00534 0.00850 Nitrate/Nitrite mg/L as N 0.0402 I

0.0892 0.0482 I

0.00645 I

0.00967 I

0.00917 I

TKN mg/L 4.27 3.04 J+

3.00 1.31 J

1.53 J

3.00 J

TN mg/L 4.31 3.13 J+

3.05 1.32 J

1.54 J

3.01 J

ortho-Phosphate mg/L 0.0500 J

0.00163 I

0.0122 0.0505 J

0.077 J

0.0612 J

Total Phosphorus (P) mg/L 0.0382 J

0.0378 0.0294 0.0332 J

0.0545 J

0.024 J

Alkalinity mg/L 288 333 280 562 210 193 187 J

190 J

183 J

254 278 219 J

Bicarbonate Alkalinity mg/L as CaCO3 288 333 280 562 210 193 187 J

190 J

183 J

254 278 219 J

Sulfide mg/L 13.3 10.3 12.9 17.2 1.89 1.00 U

9.45 1.00 U

1.00 U

9.71 10.2 6.14 Total Dissolved Solids mg/L 37500 40400 43200 27300 45600 45000 59900 54000 56000 41500 43100 52000 Dissolved Inorganic Carbon mg/L Salinity 35.68 38.75 40.11 28.01 44.47 43.54 58.93 54.95 56.25 37.85 41.5 51.98 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

09/12/2013 09/12/2013 09/12/2013 09/12/2013 09/12/2013 09/12/2013 09/06/2013 09/06/2013 09/06/2013 09/06/2013 09/06/2013 09/06/2013 TPGW-12S TPGW-11M TPGW-11S TPGW-14M TPGW-14S TPGW-14D TPGW-12D TPGW-13S TPGW-11D TPGW-13D TPGW-13M TPGW-12M

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-21 Table 3.1-2. Summary of Groundwater Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C pH SU Dissolved Oxygen mg/L Specific Conductance S/cm Turbidity NTU Silica, dissolved mg/L 0.0500 U

Calcium mg/L 0.100 U

0.100 U

0.100 U

0.100 U

0.100 U

Magnesium mg/L 0.0200 U

0.0200 U

0.0267 I

0.0200 U

0.0200 U

Potassium mg/L 0.190 U

0.190 U

0.190 U

0.190 U

0.190 U

Sodium mg/L 0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

Boron mg/L 0.01 U

0.01 U

0.01 U

0.01 U

0.01 U

Strontium mg/L 0.001 U

0.001 U

0.001 U

0.001 U

0.001 U

Bromide mg/L 0.0130 U

0.0130 U

0.0130 U

0.0130 U

0.0130 U

Chloride mg/L 0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

Fluoride mg/L 0.0240 U

0.0240 U

0.0240 U

0.179 0.0240 U

Sulfate mg/L 0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

Total Ammonia mg/L as N 0.0314 I

0.0262 I

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.0270 U

0.00540 U

TKN mg/L 0.294 0.311 TN mg/L ortho-Phosphate mg/L 0.00140 U

0.00140 U

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U

Alkalinity mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Bicarbonate Alkalinity mg/L as CaCO3 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 5.00 U

5.00 U

5.00 U

5.00 U

Dissolved Inorganic Carbon mg/L Salinity Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 060613-DUP1 is a duplicate of 060613-TPGW-6M.

Sample 060513-DUP1 is a duplicate of 060513-TPGW-9D.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

090613-EB1 091213-FB1 09/12/2013 09/11/2013 09/03/2013 09/06/2013 091113-FB1 09/04/2013 090413-FB1 090313-FB1

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-22 Table 3.1-3. Summary of Groundwater Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 26.27 26.32 26.39 25.88 26.22 26.52 25.78 25.73 25.83 25.56 25.39 25.13 24.17 24.15 24.00 23.94 24.10 24.16 pH SU 6.92 6.99 6.93 7.01 6.86 6.83 6.55 6.81 6.79 6.80 6.80 6.88 7.08 6.79 6.81 7.04 6.85 6.85 Dissolved Oxygen mg/L 0.17 0.23 0.15 0.21 0.20 0.25 0.45 0.13 0.35 0.24 0.27 0.22 0.57 0.47 0.37 0.35 0.37 1.54 Specific Conductance S/cm 40990 71492 71410 68018 74691 75916 63968 67946 69433 2057 38730 43259 1120 32585 34738 1185 22688 23614 Turbidity NTU 0.18 0.08 0.02 0.35 0.01 J

0.14 0.06 0.00 J

0.15 0.01 J

0.79 0.01 J

0.04 0.01 J

0.00 J

0.24 0.03 0.22 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 7980 15300 15100 14400 15900 16300 13400 13900 14800 228 7330 8400 98.5 6040 6430 103 3950 4050 4220 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 13500 29400 29400 27300 30500 30300 25200 27400 28600 460 15100 16300 202 11900 12500 223 7980 8350 8930 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 26000 48700 47700 46600 53400 54800 43300 46300 47700 1020 22900 26900 613 19900 19900 600 13800 13500 13800 Salinity 26.2 49.1 49.0 46.4 51.6 52.6 43.2 46.3 47.5 1.1 J

24.6 27.8 0.6 J

20.4 21.9 0.6 J

13.7 14.3 Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120213-DUP is a duplicate of TPGW-13S.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

12/02/2013 12/02/2013 12/03/2013 12/04/2013 12/03/2013 12/03/2013 12/04/2013 12/04/2013 12/02/2013 12/05/2013 12/04/2013 12/04/2013 TPGW-3S TPGW-3M 12/04/2013 TPGW-3D 12/04/2013 12/04/2013 TPGW-2M 12/05/2013 TPGW-2D 12/05/2013 TPGW-5D TPGW-1S TPGW-4S TPGW-4M TPGW-4D TPGW-1M TPGW-1D TPGW-5M TPGW-5S 120413-DUP TPGW-6M TPGW-6D TPGW-6S 12/04/2013 TPGW-2S 12/04/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-23 Table 3.1-3. Summary of Groundwater Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 24.25 24.09 24.21 24.52 25.24 24.17 25.16 24.16 24.37 26.59 26.52 26.09 26.07 25.88 25.76 25.96 26.04 26.23 pH SU 7.19 7.14 6.90 11.41 6.93 7.06 6.80 6.92 6.83 7.15 7.16 6.99 6.82 6.62 6.73 6.54 6.77 7.10 Dissolved Oxygen mg/L 0.27 0.24 0.27 0.34 0.29 0.29 0.57 0.24 0.61 0.39 0.25 0.35 0.30 0.55 0.69 0.75 0.15 0.31 Specific Conductance S/cm 535 558 1056 1412 632 669 595 621 638 52766 55326 65884 55215 57021 61193 43162 61327 64659 Turbidity NTU 0.01 J

0.06 0.25 0.82 0.09 0.44 0.67 0.21 0.12 0.08 0.00 J

0.00 J

0.00 J

0.35 0.17 0.21 0.20 0.49 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 18.8 20.2 59.4 18.2 16.7 25.1 8.77 12.7 15.5 10900 11500 14300 11500 12000 12800 8180 12900 13700 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 34.0 35.0 180 32.4 30.8 42.2 16.4 22.4 27.1 20900 25600 26600 23000 23000 23400 16400 24100 26200 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 236 268 620 300 308 376 292 324 312 34500 35300 43500 35100 38500 41400 27100 40000 43100 Salinity 0.3 J

0.3 J

0.5 J

0.7 J

0.3 J

0.3 J

0.3 J

0.3 J

0.3 J

34.7 36.7 44.7 36.6 37.9 41.1 27.8 41.2 43.7 Tritium pCi/L NOTES:

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

Text in blue is revised.

  • PSS-78 salinity is unitless.
  • PSS-78 salinity is unitless.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120213-DUP is a duplicate of TPGW-13S.

Sample 120213-DUP is a duplicate of TPGW-13S.

KEY:

KEY:

°C = Degrees Celsius.

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL. I = Value between the MDL and PQL.

12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 12/03/2013 TPGW-9S TPGW-12D 12/11/2013 TPGW-8D TPGW-12S TPGW-9M TPGW-10D 12/11/2013 TPGW-7S TPGW-7M TPGW-7D TPGW-9D TPGW-8M TPGW-12M TPGW-10S TPGW-8S 12/05/2013 12/05/2013 12/05/2013 TPGW-10M TPGW-11D TPGW-11M TPGW-11S 12/11/2013 12/11/2013 12/11/2013 12/11/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-24 Table 3.1-3. Summary of Groundwater Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 28.75 28.80 29.01 26.36 26.44 26.18 pH SU 6.84 6.85 6.92 6.79 6.70 6.73 Dissolved Oxygen mg/L 0.19 0.10 1.10 0.36 0.34 0.39 Specific Conductance S/cm 82973 78333 80246 57523 62249 74211 Turbidity NTU 0.01 J

0.01 J

0.06 0.00 J

0.16 0.87 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 17200 17400 16500 16800 12000 12800 15900 0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 35100 41800 33000 33200 22500 25500 27900 0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

0.313 I

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 58900 58800 54700 55900 37100 39300 50200 5.00 U

5.00 U

5.00 U

5.00 U

5.00 U

64.0 Salinity 58.2 54.4 56.0 38.3 41.9 51.2 Tritium pCi/L NOTES:

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

Text in blue is revised.

  • PSS-78 salinity is unitless.
  • PSS-78 salinity is unitless.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120413-DUP is a duplicate of TPGW-6D.

Sample 120213-DUP is a duplicate of TPGW-13S.

Sample 120213-DUP is a duplicate of TPGW-13S.

KEY:

KEY:

°C = Degrees Celsius.

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL. I = Value between the MDL and PQL.

12/03/2013 12/02/2013 12/02/2013 12/04/2013 120413-FB1 120313-FB1 12/11/2013 12/11/2013 12/11/2013 12/02/2013 12/02/2013 12/02/2013 120213-EB1 TPGW-13D TPGW-13S 120213-DUP 120613-FB1 TPGW-13M 121113-FB1 12/05/2013 12/06/2013 12/11/2013 TPGW-14D TPGW-14M TPGW-14S 120513-FB1

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-25 Table 3.1-4. Summary of Groundwater Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 26.07 25.89 26.35 25.73 25.65 25.99 26.08 25.71 26.18 25.32 25.05 25.20 pH SU 7.02 7.07 6.87 7.06 6.91 6.66 6.57 6.90 6.81 6.87 6.89 6.81 Dissolved Oxygen mg/L 0.33 0.28 0.63 0.14 0.19 0.19 0.16 0.12 0.28 0.44 0.30 0.66 Specific Conductance S/cm 41613 70203 71364 68244 J

74618 76333 63180 67828 69489 2485 38121 42719 Turbidity NTU 0.27 0.34 0.23 0.11 0.10 0.09 0.06 0.07 0.02 0.15 0.02 0.00 J

Calcium mg/L 454 634 637 691 692 675 700 675 632 J

646 166 579 558 Magnesium mg/L 909 1660 1630 1510 1760 1690 1810 1480 1540 J

1560 28.1 835 944 Potassium mg/L 300 602 600 554 621 611 653 516 556 J

574 5.19 201 258 Sodium mg/L 8190 15300 J

15400 J+

14200 15900 15800 16200 13200 14300 J

15200 J

291 7530 8700 Boron mg/L 3.03 6.06 5.99 5.96 6.51 6.48 6.85 5.02 5.78 5.90 0.08 1.52 2.11 Strontium mg/L 7.83 12.00 12.10 13.10 14.30 14.00 14.40 11.10 12.00 12.30 1.55 7.91 8.12 Bromide mg/L 52.1 97.4 98.6 92.5 J

104.0 102.0 106.0 84.3 92.2 J

95.3 2.2 49.7 53.5 Chloride mg/L 14700 27300 27500 27600 J

30700 30700 31000 25400 27500 J

26500 609 14000 15600 Fluoride mg/L 0.223 0.259 J

0.281 J-0.224 J

0.269 J

0.270 0.243 J

0.206 J

0.194 J

0.201 J-0.099 I

0.128 0.135 Sulfate mg/L 2000 3960 3800 3830 J

4130 4380 4370 3950 4380 J

3700 27 1780 2100 Total Ammonia mg/L as N 1.290 1.240 J

1.620 J-1.490 1.940 1.920 1.240 Ammonium ion (NH4

+)

mg/L 1.65 1.58 J

2.07 J-1.90 2.48 1.59 Unionized NH3 mg/L 0.01000 0.01060 J

0.00908 J-0.01240 0.01140 0.00419 Nitrate/Nitrite mg/L as N 0.0270 U

0.0270 U

0.0270 U

0.0337 I

0.0336 I

0.0316 I

0.0318 I

TKN mg/L 1.83 2.23 2.20 2.06 2.88 2.75 2.78 TN mg/L 1.86 2.26 2.23 2.09 2.91 2.78 2.81 ortho-Phosphate mg/L 0.0101 J

0.0101 J

0.0460 0.0177 J

0.0425 J

0.0417 0.0449 Total Phosphorus (P) mg/L 0.0039 IJ 0.0022 UJ 0.0570 0.0022 UJ 0.0290 J

0.0313 0.0439 Alkalinity mg/L 269 182 180 185 J

202 203 197 484 241 J

223 322 211 203 Bicarbonate Alkalinity mg/L as CaCO3 269 182 180 185 J

202 203 197 484 241 J

223 322 211 203 Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U Q 1.00 U Q 1.00 U Q 1.00 U

22.00 Q

1.00 U Q 1.00 U Q 1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 25300 48800 48700 47800 53100 52700 55200 42000 47000 47700 1390 23100 26900 Salinity 26.63 48.06 48.96 46.53 J

51.56 52.93 42.61 46.22 47.5 1.27 J

24.19 27.45 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030414-DUP1 is a duplicate of TPGW-2M.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

030414-DUP 03/11/2014 03/11/2014 03/11/2014 03/04/2014 03/04/2014 03/04/2014 03/04/2014 03/04/2014 03/04/2014 03/04/2014 TPGW-1D TPGW-1M TPGW-4S 03/10/2014 03/10/2014 TPGW-4M TPGW-4D 03/10/2014 TPGW-3S TPGW-3D TPGW-3M TPGW-2D TPGW-2M TPGW-2S TPGW-1S

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-26 Table 3.1-4. Summary of Groundwater Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 23.87 24.04 23.80 23.84 23.93 23.92 23.50 23.40 23.48 24.06 23.80 24.17 pH SU 7.24 6.61 6.80 7.10 6.81 6.90 7.22 7.20 6.64 11.86 7.10 6.87 Dissolved Oxygen mg/L 0.53 0.79 0.48 0.35 0.73 0.21 0.37 0.37 0.97 0.43 0.45 0.73 Specific Conductance S/cm 1012 32620 34101 1211 22635 23241 527 534 3029 1978 J

629 655 Turbidity NTU 0.38 0.21 0.22 0.01 J

0.00 J

0.06 0.42 0.36 0.12 0.41 0.04 0.14 Calcium mg/L 109 578 566 124 478 494 86 85 85 261 175 J

112 103 Magnesium mg/L 7.2 632 687 12.1 412 439 4.27 4.04 4.04 11.5 0.02 UJ 4.18 5.65 Potassium mg/L 5.8 142 176 4.65 101 107 7.7 7.57 7.44 8.38 10.2 J

11.4 9.11 Sodium mg/L 86 6060 6570 104 3910 4160 20 20 20 278 18 J

17 24 Boron mg/L 0.07 0.99 1.35 0.06 0.80 0.85 0.05 0.05 0.05 0.06 0.05 0.07 0.07 Strontium mg/L 1.07 7.37 7.80 1.23 7.97 8.23 0.84 0.83 0.82 2.64 0.62 1.13 1.04 Bromide mg/L 0.6 40.2 43.9 0.8 27.0 27.7 0.2 0.2 0.2 2.9 0.2 J

0.2 0.3 Chloride mg/L 165 11300 12400 212 7740 8070 34 35 35 825 35 J

31 43 Fluoride mg/L 0.119 0.125 0.142 0.121 0.127 0.140 0.133 0.121 0.121 0.091 I

0.090 IJ 0.095 I

0.093 I

Sulfate mg/L 19 1320 1490 9

835 871 22 25 25 19 50 J

66 57 Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L 237 232 217 289 202 J

217 J

201 200 200 174 257 J

220 226 Bicarbonate Alkalinity mg/L as CaCO3 237 232 217 289 202 J

217 J

210 200 200 174 1

UJ 220 226 Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 553 19300 20900 693 14700 15700 272 272 252 2200 410 J

340 344 Salinity 0.49 J

20.38 21.39 0.6 J

13.65 14.05 0.25 J

0.26 J

1.58 J

1.01 J

0.3 J

0.32 J

Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030414-DUP1 is a duplicate of TPGW-2M.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

03/05/2014 03/05/2014 TPGW-7M 03/10/2014 03/11/2014 03/11/2014 03/11/2014 03/11/2014 03/10/2014 03/10/2014 03/11/2014 03/05/2014 03/11/2014 TPGW-7S TPGW-8D TPGW-8S TPGW-7D TPGW-8M TPGW-6D TPGW-6M TPGW-6S TPGW-5M TPGW-5S 031114-DUP 03/11/2014 TPGW-5D

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-27 Table 3.1-4. Summary of Groundwater Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 24.42 23.84 23.74 26.19 26.36 26.16 25.58 25.56 25.58 26.39 26.02 25.97 pH SU 6.72 6.76 6.95 7.32 7.33 7.00 6.98 6.67 6.81 6.48 6.64 7.09 Dissolved Oxygen mg/L 0.53 1.11 0.46 0.31 0.21 0.35 0.42 0.30 0.11 0.62 0.72 0.13 Specific Conductance S/cm 594 596 625 52152 54497 66201 54319 56935 61402 44292 61622 64257 Turbidity NTU 0.15 2.01 0.10 0.30 0.40 0.37 0.49 0.23 0.22 0.17 0.01 J

0.01 J

Calcium mg/L 117 128 112 434 448 564 500 549 591 J

481 J

565 596 Magnesium mg/L 2.7 3.03 3.47 1190 1200 1500 1210 1290 1370 J

979 J

1370 1480 Potassium mg/L 5.47 5.81 3.8 436 447 553 457 470 511 J

328 J

475 516 Sodium mg/L 12 13 15 11000 11300 13900 11500 12000 13400 J

8560 J

12600 13400 Boron mg/L 0.05 0.06 0.05 4.67 4.83 5.73 5.10 5.06 5.23 3.50 4.91 5.23 Strontium mg/L 0.97 1.07 1.13 8.08 8.49 10.60 8.66 9.52 10.40 7.33 10.00 10.60 Bromide mg/L 0.2 0.2 0.4 68.3 73.6 91.0 72.3 75.7 83.4 J

54.2 J

80.5 120.0 Chloride mg/L 20 22 27 19300 21100 25800 20500 21900 32800 J

16800 J

23200 25900 Fluoride mg/L 0.099 I

0.093 I

0.085 I

0.783 0.595 0.263 J

0.809 0.567 0.654 J

0.414 J

0.259 J-0.250 J

Sulfate mg/L 7

11 30 2740 2780 3570 2870 3160 3310 J

2180 J

3210 3600 Total Ammonia mg/L as N 0.382 0.391 0.811 J

Ammonium ion (NH4

+)

mg/L 0.49 0.50 1.04 J

Unionized NH3 mg/L 0.00592 0.00627 0.00604 J

Nitrate/Nitrite mg/L as N 0.0270 U

0.0270 U

0.0270 U

TKN mg/L 0.76 0.64 1.11 TN mg/L 0.79 0.67 1.14 ortho-Phosphate mg/L 0.0461 J

0.0202 J

0.0452 J

Total Phosphorus (P) mg/L 0.0022 UJ 0.0022 UJ 0.0039 IJ Alkalinity mg/L 278 273 262 129 116 158 289 341 275 J

556 J

267 J

197 J

Bicarbonate Alkalinity mg/L as CaCO3 278 273 262 129 116 158 289 341 275 J

556 J

267 J

197 J

Sulfide mg/L 1.28 1.00 U

1.00 U

4.32 1.00 U Q 3.84 11.20 6.72 Q

4.97 Q

19.40 4.09 Q

1.00 U Q Total Dissolved Solids mg/L 280 280 304 32900 36800 45000 35500 37400 42900 28900 44100 45300 Salinity 0.29 J

0.29 J

0.3 J

34.29 36.03 44.94 35.92 37.88 41.26 28.55 41.44 43.44 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030414-DUP1 is a duplicate of TPGW-2M.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

03/12/2014 03/12/2014 03/12/2014 03/12/2014 03/12/2014 03/12/2014 03/05/2014 03/05/2014 03/10/2014 03/10/2014 03/10/2014 03/05/2014 TPGW-12S TPGW-11M TPGW-11S TPGW-10S TPGW-9D TPGW-9M TPGW-9S TPGW-12D TPGW-11D TPGW-10D TPGW-10M TPGW-12M

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-28 Table 3.1-4. Summary of Groundwater Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 29.47 29.50 29.43 25.82 25.56 26.08 pH SU 6.76 6.76 7.03 6.96 6.83 6.71 Dissolved Oxygen mg/L 0.30 0.45 0.13 0.30 0.25 0.42 Specific Conductance S/cm 82533 78500 79151 56577 60817 73672 Turbidity NTU 0.01 J

0.02 0.19 0.23 0.25 0.34 Calcium mg/L 714 696 686 526 567 649 0.100 U

0.100 U

0.100 U

0.100 U

0 U

Magnesium mg/L 2000 1850 1870 1310 1340 1660 0.0200 U

0.0200 U

0.0200 U

0.0200 U

0 U

Potassium mg/L 710 651 658 474 509 632 0.190 U

0.190 U

0.190 U

0.190 U

0 U

Sodium mg/L 17800 16600 17200 12200 13100 16000 0.310 U

0.310 U

0.310 U

0.310 U

0 U

Boron mg/L 7.45 6.75 7.13 5.03 5.37 6.69 0.01 0.01 0.01 0.01 0

U Strontium mg/L 14.30 14.20 14.10 9.37 10.10 12.90 0.00 0.00 0.00 0.00 0

U Bromide mg/L 115.0 108.0 109.0 76.0 83.1 103.0 0.0130 U

0.0130 U

0.0130 U

0.0130 U

0.0 U

Chloride mg/L 32900 31500 31400 20900 24100 29200 0.476 I

0.250 U

0.250 U

0.250 U

0 U

Fluoride mg/L 0.339 0.196 0.210 0.514 0.431 J

0.397 J

0.0240 U

0.0240 U

0.0240 U

0.0240 U

0.024 U

Sulfate mg/L 4680 4320 4220 3170 3340 4060 0.250 U

0.250 U

0.304 I

0.250 U

0 U

Total Ammonia mg/L as N 2.540 1.820 1.100 0.647 1.160 J

1.050 J

0.0260 U

0.0260 U

0.0260 U

0.0260 U

0.0260 U

Ammonium ion (NH4

+)

mg/L 3.25 2.33 1.40 0.83 1.49 J

1.35 J

Unionized NH3 mg/L 0.01370 0.00986 0.01100 0.00430 0.00562 J

0.00400 J

Nitrate/Nitrite mg/L as N 0.0335 I

0.0270 U

0.0391 I

0.0270 U

0.0270 U

0.0270 U

0.02700 U

0.02700 U

0.02700 U

0.02700 U

0.02700 U

TKN mg/L 2.74 2.27 2.65 0.99 1.51 3.09 0.300 U

0.300 U

0.300 U

0.300 U

0.30 U

TN mg/L 2.77 2.30 2.69 1.02 1.54 3.12 0.33 0.33 0.33 0.33 0.33 ortho-Phosphate mg/L 0.0533 J

0.0043 I J 0.0127 J

0.0434 J

0.0665 J

0.0563 J

0.00324 I

0.00413 I

0.00399 I

0.00179 I

0.00293 I

Total Phosphorus (P) mg/L 0.0052 IJ 0.0075 I

0.0022 UJ 0.0022 UJ 0.0025 IJ 0.0044 IJ 0.00220 U

0.00220 U

0.00220 U

0.00220 U

0.00220 U

Alkalinity mg/L 116 J

178 J

188 J

236 284 225 1.00 U

27.60 1.00 U

1.00 U

1 U

Bicarbonate Alkalinity mg/L as CaCO3 116 J

178 J

188 J

236 284 255 1.00 U

27.60 1.00 U

1.00 U

1 U

Sulfide mg/L 5.71 1.00 U Q 1.00 U Q 4.74 Q

7.59 Q

4.26 Q

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 60300 55700 59100 36800 41400 51400 5

U 5

U 5

U 5

U 5

U Salinity 57.81 54.54 55.07 37.6 40.81 50.8 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030414-DUP1 is a duplicate of TPGW-2M.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

031214-FB1 03/12/2014 031014-FB1 03/11/2014 03/12/2014 03/12/2014 03/12/2014 03/04/2014 03/10/2014 031114-FB1 03/05/2014 03/05/2014 03/05/2014 03/05/2014 030514-FB1 TPGW-14M TPGW-14S TPGW-14D 030414-FB1 TPGW-13S TPGW-13D TPGW-13M

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-29 Table 3.1-5. Summary of Groundwater Analytical Results from the June 2013 Historical Well Sampling Event Parameter Units Temperature

°C 26.39 27.97 27.13 27.75 25.02 25.16 25.57 25.19 24.59 24.87 pH SU 7.14 6.86 7.2 6.84 6.9 6.64 7.94 6.79 6.94 7.16 Dissolved Oxygen mg/L 0.4 J

0.23 J

1.23 J

0.29 J

0.56 0.36 0.28 0.31 0.35 0.32 Specific Conductance S/cm 1179 79416 547 74968 518 17408 7850 39487 634 14447 Turbidity NTU 3.01 0.14 1.66 0.15 0.71 0.32 59.73 27.6 0.94 0.3 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 123 19500 41.2 18400 23.2 22.9 2820 1190 7460 26.8 2450 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 240 32700 78.4 30900 51.7 48 6250 2670 16000 48.4 J+

5070 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 627 50600 296 48500 268 264 12000 4460 24300 348 8300 Salinity 0.58 J

55.34 0.26 J

51.78 0.25 J

10.24 4.34 25.15 0.31 J

8.37 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

KEY:

°C = Degrees Celsius.

mg/L = Milligram(s) per liter.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

N = Nitrogen.

SU = Standard Unit(s).

= sigma (Standard Deviation).

NH3 = Ammonia.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH4

+ = Ammonium ion.

TN = Total nitrogen.

J = Estimated (+/- indicate bias).

NTU = Nephelometric Turbidity Units(s).

TPGW = Turkey Point Groundwater.

6/10/2013 6/10/2013 TPGW-G35-18 6/10/2013 6/10/2013 6/10/2013 TPGW-G28-58 6/10/2013 6/10/2013 061013-DUP1 TPGW-G35-58 TPGW-G21-18 TPGW-G21-58 TPGW-G28-18 TPGW-L3-18 TPGW-L3-58 TPGW-L5-18 TPGW-L5-58 6/7/2013 6/7/2013 6/7/2013 6/7/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-30 Table 3.1-6. Summary of Groundwater Analytical Results from the September 2013 Historical Well Sampling Event Parameter Units Temperature

°C 27.92 28.67 29.60 28.86 26.19 25.81 25.93 25.75 24.88 24.77 pH SU 7.37 6.89 7.26 6.87 7.28 6.71 8.25 6.84 7.23 7.17 Dissolved Oxygen mg/L 0.15 0.22 0.14 0.20 0.20 J

0.04 J

0.19 J

0.03 J

0.21 J

0.31 J

Specific Conductance S/cm 704 79173 1727 75809 532 17131 5034 39083 592 17918 Turbidity NTU 2.53 0.06 0.72 0.07 1.42 0.53 19.45 10.00 0.27 0.22 Silica, dissolved mg/L Calcium mg/L 67.4 677 83.9 735 87.5 87.0 635 259 593 90.7 313 0.100 U

0.100 U

Magnesium mg/L 7.69 1790 22.8 1810 3.82 3.80 221 70.0 807 5.59 342 0.0200 U

0.0200 U

Potassium mg/L 2.49 671 9.30 671 4.54 4.43 25.7 14.5 198 9.42 102 0.190 U

0.190 U

Sodium mg/L 66.3 16900 225 17100 23.9 23.5 2690 988 7140 21.3 3000 0.310 U

0.310 U

Boron mg/L 0.0457 I

7.09 0.105 6.87 0.064 0.048 I

0.155 I

0.195 I

1.43 0.0655 1.53 0.01 U

0.01 U

Strontium mg/L 0.644 13 0.88 15.2 0.771 0.769 6.52 2.35 7.17 0.858 4.59 0.001 U

0.001 U

Bromide mg/L 0.379 117 1.57 108 0.224 0.214 21.6 7.57 45.4 0.315 21.7 0.0130 U

0.0130 U

Chloride mg/L 134 34800 443 33300 46.6 45.1 6440 2210 15300 37.6 6490 0.250 U

0.250 U

Fluoride mg/L 0.0923 I

0.299 0.0923 I

0.193 0.118 0.114 0.0870 I

0.0783 I

0.131 0.126 0.159 0.0240 U

0.0240 U

Sulfate mg/L 2.11 4350 32.2 4080 10.5 J

8.48 J

216 173 1730 59.9 867 0.250 U

0.250 U

Total Ammonia mg/L as N 0.0260 U

0.0261 I

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.00760 I

0.00540 U

TKN mg/L 0.366 0.255 TN mg/L ortho-Phosphate mg/L 0.00140 U

0.00140 U

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U

Alkalinity mg/L 153 185 181 189 204 201 201 118 212 176 167 1.00 U

1.00 U

Bicarbonate Alkalinity mg/L as CaCO3 153 185 181 189 204 201 201 118 212 176 167 1.00 U

1.00 U

Sulfide mg/L 1.12 1.67 1.12 1.00 U

1.15 1.00 U

1.00 U

1.28 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 412 56600 890 52000 292 288 10900 4120 24100 324 10300 Salinity 0.34 J

55.12 0.87 J

52.41 0.26 J

10.08 3.43 24.83 0.29 J

10.58 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 090913-DUP1 is a duplicate of G21-18.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter. mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

I = Value between the MDL and PQL.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

09/10/2013 09/10/2013 09/10/2013 09/09/2013 09/09/2013 TPGW-G35-18 090913-DUP TPGW-G21-18 09/09/2013 09/09/2013 09/09/2013 090913-FB1 091013-FB1 09/09/2013 09/10/2013 TPGW-L5-58 09/10/2013 09/09/2013 09/09/2013 TPGW-G35-58 TPGW-L3-18 TPGW-L3-58 TPGW-L5-18 TPGW-G21-58 TPGW-G28-18 TPGW-G28-58

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-31 Table 3.1-7. Summary of Groundwater Analytical Results from the December 2013 Historical Well Sampling Event Parameter Units Temperature

°C 27.16 27.58 27.28 27.85 25.22 24.86 25.04 24.99 24.67 24.54 pH SU 6.92 6.80 7.18 6.80 6.94 6.64 7.93 6.86 7.10 7.12 Dissolved Oxygen mg/L 0.44 0.31 0.29 0.32 0.64 0.42 0.37 0.83 0.36 0.32 Specific Conductance S/cm 2298 78688 980 74021 579 17273 5610 38640 645 18389 Turbidity NTU 1.34 0.01 J

0.99 0.01 J

1.31 0.4 105.40 47.70 1.75 0.01 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 292.0 16900 93 15900 24.8 2880.0 941 7070 31 30.5 3150 0.310 U

0.310 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 556 33000 189 30200 45.6 5540.0 1910 14900 56 60.4 6230 0.250 U

0.250 U

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as Sulfide mg/L Total Dissolved Solids mg/L 940 57100 480 52700 308 9700 3140 24200 336 320 9600 5

U 5

U Salinity 1.17 J

54.77 0.48 J

51.02 0.2 J

10.16 3.03 24.56 0.31 J

10.88 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 120613-DUP1 is a duplicate of 120613-TPGW-G35-18.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimetermg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

TPGW-L3-18 12/06/2013 12/06/2013 TPGW-G21-18 12/06/2013 TPGW-G35-58 TPGW-L3-58 12/06/2013 12/05/2013 12/05/2013 12/06/2013 12/06/2013 12/05/2013 12/05/2013 TPGW-G28-58 12/06/2013 TPGW-G21-58 120513-FB1 120613-FB1 120613-DUP TPGW-L5-18 TPGW-L5-58 12/06/2013 TPGW-G28-18 TPGW-G35-18 12/05/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-32 Table 3.1-8. Summary of Groundwater Analytical Results from the March 2014 Historical Well Sampling Event Parameter Units Temperature

°C 26.19 26.86 24.50 25.54 24.61 24.37 25.26 24.90 25.21 24.62 pH SU 7.24 6.95 7.36 6.87 7.40 6.7 9.46 6.92 7.56 7.10 Dissolved Oxygen mg/L 0.47 0.56 0.61 0.43 0.88 0.4 4.58 0.45 0.77 0.35 Specific Conductance S/cm 837 77142 799 72566 538 16305 1673 38299 755 18096 Turbidity NTU 0.81 0.12 0.75 0.07 0.51 0.09 0.85 81.31 1.10 0.25 Silica, dissolved mg/L 0.05 U

0.05 U

Calcium mg/L 79.4 671 80.8 669 80.5 581.0 98 587 69 67.9 307 0.100 U

0.100 U

Magnesium mg/L 10.80 1790 9.5 1660 3.80 180.00 22 802.0 8

7.52 340 0.0200 U

0.0200 U

Potassium mg/L 3.57 667 3.30 594 4.53 29.00 8.3 208.0 13 12.30 114 0.190 U

0.190 U

Sodium mg/L 76.0 17100 68 16200 J

23.6 2700.0 350 7540 66 65.2 3350 0.310 U

0.310 U

Boron mg/L 0.0586 6.99 0.0643 6.06 0.0409 I

0.151 0.139 1.53 0.0857 0.0846 1.66 0.01 U

0.01 U

Strontium mg/L 0.767 13.5 0.791 15.1 0.833 7.27 1.1 8.15 0.957 0.95 5.21 0.001 U

0.001 U

Bromide mg/L 0.346 109 0.36 103 0.189 20.500 2.4 49.50 0.6 0.585 20.9 0.0130 U

0.0130 U

Chloride mg/L 141 31700 122 28800 42.9 5810.0 676 13800 116 117.0 6020 0.250 U

0.364 I

Fluoride mg/L 0.0915 I

0.317 J

0.0797 I

0.180 J-0.121 0.091 I

0.0451 I

0.1420 0.138 0.142 0.162 0.0240 U

0.0240 U

Sulfate mg/L 20.60 4550 10.3 J

3970 14.7 209.00 104 1760 76 76.7 925 0.338 I

1.110 Total Ammonia mg/L as N 0.0260 U

0.0260 U

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.03780 I

0.05550 TKN mg/L 0.300 U

0.300 U

TN mg/L 0.3378 0.3555 ortho-Phosphate mg/L 0.00190 I

0.00140 U

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U

Alkalinity mg/L 187 183 210 192 196 203 76 217 115 118 170 1.00 U

1.00 U

Sulfide mg/L 1.00 U Q 1.00 U Q 1.84 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 440 55300 368 50800 276 10400 960 23700 368 348 10100 5

U 5

U Salinity 0.41 J

53.55 0.39 J

49.93 0.26 J

9.56 0.84 J

24.33 0.37 J

10.69 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 030614-DUP1 is a duplicate of G35-18.

Sample 031114-DUP1 is a duplicate of TPGW-7M.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

030614-FB1 030714-FB1 03/06/2014 03/07/2014 TPGW-L5-58 03/07/2014 03/06/2014 03/06/2014 TPGW-G35-58 TPGW-L3-18 TPGW-L3-58 TPGW-L5-18 TPGW-G28-18TPGW-G28-58TPGW-G35-18 030614-DUP TPGW-G21-58 TPGW-G21-18 03/06/2014 03/06/2014 03/06/2014 03/07/2014 03/07/2014 03/07/2014 03/06/2014 03/06/2014

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-33 Table 3.1-9. Range of Ion and Nutrient Concentrations in Groundwater Parameter Units Min Max Average Std Dev Min Max Average Std Dev Min Max Average Std Dev Min Max Average Std Dev Min Max Average Std Dev Min Max Average Std Dev Temperature

°C 23.80 28.86 26.08 1.02 18.32 29.40 25.89 1.66 23.40 29.60 24.93 1.03 22.05 30.12 24.82 1.14 28.75 29.58 29.30 0.30 28.83 30.47 29.73 0.44 pH SU 6.48 7.53 6.87 0.20 6.45 7.64 7.01 0.21 6.64 11.86 7.27 1.04 6.74 12.10 7.57 1.15 6.73 7.03 6.84 0.08 6.52 7.25 7.01 0.15 Dissolved Oxygen mg/L 0.03 1.93 0.42 0.33 0.05 1.67 0.25 0.20 0.03 4.58 0.53 0.54 0.05 1.29 0.26 0.22 0.02 1.10 0.33 0.30 0.06 1.08 0.26 0.30 Specific Conductance S/cm 22635 79416 57502 15860 19640 84800 56598 16703 518 39487 4645 9325 429 41949 4462 8946 78333 83887 80743 2011 70180 90261 82289 5029 Turbidity NTU 0.00 1.42 0.23 0.23 0.00 7.40 0.80 1.03 0.00 105.40 4.92 17.03 0.00 31.92 2.64 4.88 0.01 1.07 0.16 0.30 0.00 1.55 0.51 0.45 Calcium mg/L 411.00 1080.00 597.86 99.41 400.00 870.00 597.40 88.82 67.40 635.00 171.50 156.26 48.00 590.00 165.34 134.37 686.00 758.00 711.50 26.50 690.00 790.00 746.19 32.01 Magnesium mg/L 403.00 1810.00 1295.64 410.84 420.00 2200.00 1438.18 495.24 0.02 807.00 75.26 188.78 0.02 910.00 66.79 181.31 1720.00 2010.00 1883.33 108.38 2000.00 2500.00 2233.33 115.47 Potassium mg/L 101.00 671.00 456.53 175.00 92.00 1400.00 446.03 192.77 2.49 208.00 22.79 47.63 2.60 440.00 23.29 55.54 651.00 753.00 692.83 37.57 600.00 800.00 709.52 52.96 Sodium mg/L 3790.00 18900.00 11840.52 3828.98 3800.00 21000.00 11660.42 3920.32 8.05 7540.00 619.95 1551.72 6.00 8300.00 642.26 1593.12 16500.00 18100.00 17083.33 547.45 16000.00 20000.00 17857.14 1195.23 Boron mg/L 0.79 7.09 4.61 1.95 0.58 7.50 4.38 1.94 0.03 1.66 0.22 0.45 0.03 1.60 0.19 0.40 6.75 7.55 7.13 0.32 6.60 8.70 7.51 0.61 Strontium mg/L 6.09 15.20 10.31 2.36 6.30 15.00 10.23 2.36 0.58 8.15 1.87 2.06 0.53 7.70 1.76 1.79 13.40 14.30 14.02 0.33 14.00 16.00 14.43 0.60 Bromide mg/L 26.50 120.00 78.24 25.30 23.00 180.00 76.60 29.66 0.15 49.50 5.16 11.68 0.03 62.00 4.26 11.00 108.00 122.00 113.83 5.12 49.00 130.00 108.57 16.91 Chloride mg/L 7740 34800 23268 7254 7100 34000 22247 7492 16 16000 1540 3592 10 15000 1358 3279 31400 39800 34925 2604 26000 38000 34476 2750 Fluoride mg/L 0.12 0.81 0.31 0.19 0.01 3.30 0.44 0.55 0.05 0.16 0.11 0.02 0.02 0.65 0.13 0.11 0.19 0.35 0.25 0.07 0.02 3.60 0.80 1.04 Sulfate mg/L 825.00 4550.00 2998.33 1035.81 680 4500.00 2734.61 1005.28 2.11 1760.0 171.7 414.1 0.92 1800 156 369 4120 4820 4457 278 3700.0 5000.0 4257.1 395.7 Total Ammonia mg/L as N 0.298 2.080 1.156 0.550 0.220 2.000 1.097 0.600 NA NA NA NA NA NA NA NA 1.100 2.590 1.872 0.593 1.300 2.800 1.844 0.482 Ammonium ion (NH4

+)

mg/L 0.378 2.670 1.478 0.705 0.280 2.600 1.378 0.794 NA NA NA NA NA NA NA NA 1.400 3.310 2.392 0.761 1.656 3.600 2.336 0.627 Unionized NH3 mg/L 0.003 0.015 0.008 0.003 0.003 0.025 0.010 0.006 NA NA NA NA NA NA NA NA 0.010 0.014 0.012 0.002 0.014 0.184 0.039 0.055 Nitrate/Nitrite mg/L as N 0.005 0.128 0.028 0.023 0.005 1.200 0.093 0.239 NA NA NA NA NA NA NA NA 0.027 0.089 0.046 0.022 0.012 0.340 0.104 0.110 Total Kjedahl Nitrogen mg/L 0.640 3.160 1.923 0.852 0.260 2.700 1.425 0.793 NA NA NA NA NA NA NA NA 2.270 4.270 2.995 0.684 1.500 3.500 2.333 0.608 Total Nitrogen mg/L 0.667 3.187 1.951 0.849 0.260 2.700 1.442 0.788 NA NA NA NA NA NA NA NA 2.297 4.310 3.041 0.688 1.500 3.800 2.433 0.680 ortho-Phosphate mg/L 0.00 0.08 0.04 0.02 0.014 0.10 0.04 0.02 NA NA NA NA NA NA NA NA 0.00 0.05 0.02 0.02 0.02 0.04 0.03 0.00 Total Phosphorus (P) mg/L 0.00 0.06 0.02 0.02 0.015 0.08 0.03 0.01 NA NA NA NA NA NA NA NA 0.00 0.04 0.02 0.02 0.04 0.07 0.05 0.01 Alkalinity mg/L 103.00 562.00 234.33 89.89 48 550.00 209.68 73.09 75.50 332.00 216.41 54.45 30.00 580 224.73 83.32 116 190 174 29 54.00 220.00 165.43 36.07 Bicarbonate Alkalinity mg/L as CaCO3 103.00 562.00 234.84 89.92 48.0 550.00 209.68 73.09 1.00 332.00 205.71 71.76 1.00 360 200.17 72.78 116 190 174 29 54.00 220.0 165.4 36.1 Sulfide mg/L 1.00 22.00 4.04 5.04 1.0 22.00 3.22 4.03 1.00 1.84 1.08 0.16 1.00 8.30 1.11 0.73 1.00 9.45 3.19 3.60 1.00 25.00 7.14 9.13 Total Dissolved Solids mg/L 12800 57100 38428 11929 12000 64000 38208 12850 236 24300 2746 5756 160 26000 2558 5486 54000 60300 57000 2180 56000 75000 60857 5842 Salinity (PSS-78) 13.65 55.34 38.61 11.70 11.68 59.82 37.96 12.31 0.20 25.15 2.75 5.86 0.21 26.93 2.62 5.63 54.43 58.93 56.37 1.63 47.90 64.20 57.63 4.07 Tritium pCi/L (1)

NOTES:

  • PSS-78 salinity is unitless.

Marine wells include: TPGW-1S, -1M, -1D, -2S, -2M, -2D, -3S, -3M, -3D, -4M, -4D, -5M, -5D, -6M, -6D, -10S, -10M, -10D, -11S, -11M, -11D, -12S, -12M, -12D, -14S, -14M, -14D Fresh wells include: TPGW-4S, -5S, -6S, -7S, -7M, -7D, -8S, -8M, -8D, -9S, -9M, -9D, -L3-18, -L5-18, -G21-18, -G21-58, -G28-18, -G28-58, -G35-18, -G35-58 KEY:

°C = Degrees Celsius.

Min = Minimum.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

N = Nitrogen.

SU = Standard Unit(s).

= sigma (Standard Deviation).

NA = Not available.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

Max = Maximum.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

mg/L = Milligram(s) per liter.

NTU = Nephelometric Turbidity Units(s).

Post-Uprate Post-Uprate Marine Fresh TPGW-13 Post-Uprate Pre-Uprate Pre-Uprate Pre-Uprate

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-34 Table 3.2-1. Summary of Surface Water Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 28.52 29.14 29.47 29.49 26.7 28.6 28.08 28.35 28.46 27.11 27.16 29.83 27.19 pH SU 7.85 7.68 7.79 7.77 7.14 7.68 7.56 7.6 7.59 6.9 6.92 7.83 7.49 Dissolved Oxygen mg/L 4.21 5.32 5.22 6.71 J

1.12 J

5.42 J

5.04 J

6 J

7.1 J

2.1 0.19 6.67 2.43 Specific Conductance S/cm 53783 52173 46171 402 442 582 570 556 555 42969 48000 50933 J

55524 Turbidity NTU 1.94 1.24 0.79 0.65 1.34 0.69 1.11 0.59 0.51 1.58 8.23 0.73 6.73 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 10800 10600 8610 8900 30.9 32.6 54.8 55.4 50.4 51.4 8460 9560 9570 11500 10300 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 20900 21300 17000 17900 53.9 55.2 106 106 95.6 95.4 16300 19500 18700 22900 J

21500 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L Salinity 35.4 34.2 29.8 0.2 J

0.2 J

0.3 J

0.3 J

0.3 J

0.3 J

27.6 31.3 33.3 J

36.8 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

061113-DUP1 is a field duplicate of sample 061113-TPSWC-4B.

061313-DUP1 is a field duplicate of sample 061313-TPBBSW-5B.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

FB = Field blank.

TPBBSW-3B 6/13/2013 6/13/2013 6/7/2013 061113-DUP1 TPSWC-5T 6/11/2013 6/13/2013 TPSWC-1B TPSWC-5B TPSWC-2B 6/7/2013 TPSWC-4T 6/11/2013 TPSWC-4B 6/13/2013 6/11/2013 TPSWC-3T 6/7/2013 TPBBSW-4B 061313-Dup1 TPSWC-2T TPBBSW-5B TPSWC-3B 6/11/2013 TPSWC-1T 6/7/2013 6/7/2013 6/7/2013 6/11/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-35 Table 3.2-1. Summary of Surface Water Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C 25.23 25.18 36.14 29.14 29.35 28.13 28.72 27.59 40.33 36.51 33.55 31.51 32.47 37.76 pH SU 7.23 7.25 8.06 7.85 7.85 7.01 7.64 7.72 8.87 8.56 8.69 8.69 8.67 8.84 Dissolved Oxygen mg/L 2.62 2.17 5.79 5.17 6.25 0.43 4.74 5.02 4.28 8.45 4.86 5.55 5.14 6.38 Specific Conductance S/cm 808 818 4088 6510 3293 13700 3644 4006 75276 75280 74015 74816 74451 75876 Turbidity NTU 0.51 0.41 0.74 0.9 0.41 20.55 0.51 0.39 32.12 28.15 39.69 39.85 31.7 32.17 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 50 51.2 588 997 467 2300 497 571 15400 15700 15300 15500 15300 15300 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 83.2 89.5 1210 1920 885 4300 969 1120 31000 33400 30200 32100 29800 30600 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L Salinity 0.4 J

0.4 J

2.2 3.5 1.7 J

7.9 1.9 J

2.1 51.4 51.6 50.8 51.5 51.2 51.4 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

061113-DUP1 is a field duplicate of sample 061113-TPSWC-4B.

061313-DUP1 is a field duplicate of sample 061313-TPBBSW-5B.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

FB = Field blank.

6/3/2013 TPSWCCS-4T 6/3/2013 TPSWID-3T TPSWC-6T TPSWID-2B TPSWID-1T TPSWID-1B TPSWC-6B TPSWCCS-1B TPSWID-2T TPSWID-3B TPSWCCS-3B TPSWCCS-2B TPSWCCS-5T TPSWCCS-7B 6/11/2013 6/3/2013 6/3/2013 6/3/2013 6/3/2013 6/3/2013 6/3/2013 6/5/2013 6/5/2013 6/3/2013 6/3/2013 6/3/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-36 Table 3.2-1. Summary of Surface Water Analytical Results from the June 2013 Sampling Event Parameter Units Temperature

°C pH SU Dissolved Oxygen mg/L Specific Conductance S/cm Turbidity NTU Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 0.25 U

0.25 U

0.25 U

0.25 U

0.25 U

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N 0.026 U

Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N 0.005 U

TKN mg/L 0.236 TN mg/L ortho-Phosphate mg/L 0.001 U

Total Phosphorus (P) mg/L 0.002 U

Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 5

U 5

U Salinity Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

Text in blue is revised.

  • PSS-78 salinity is unitless.

061113-DUP1 is a field duplicate of sample 061113-TPSWC-4B.

061313-DUP1 is a field duplicate of sample 061313-TPBBSW-5B.

KEY:

°C = Degrees Celsius.

J = Estimated (+/- indicate bias).

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

= sigma (Standard Deviation).

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH3 = Ammonia.

TN = Total nitrogen.

DUP = Duplicate.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

FB = Field blank.

061313-FB1 6/13/2013 060713-FB1 060313-FB1 6/3/2013 061113-EB1 6/11/2013 060513-FB1 6/5/2013 6/7/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-37 Table 3.2-2. Summary of Surface Water Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 29.10 28.42 28.29 28.71 28.54 28.83 29.00 29.93 29.56 29.06 29.92 30.60 30.71 pH SU 8.13 8.04 7.88 7.48 7.32 7.73 7.54 7.78 7.68 7.48 7.63 7.94 7.76 Dissolved Oxygen mg/L 5.30 5.29 4.41 3.47 1.65 4.77 2.74 5.02 4.24 2.86 3.23 5.14 4.04 Specific Conductance S/cm 49303 J

52612 J

50460 J

576 593 578 588 608 614 23204 J

47521 J

52069 J

53157 J

Turbidity NTU 0.92 0.77 1.10 0.54 1.17 1.19 0.84 0.63 0.52 2.40 9.43 0.56 1.01 Silica, dissolved mg/L Calcium mg/L 410 408 396 54.3 53.6 53.9 50.2 51.7 52.5 52.2 251 394 415 443 Magnesium mg/L 1110 J-1110 J-1070 J-6.93 6.76 6.80 6.43 6.62 6.26 6.09 420 954 1120 1190 Potassium mg/L 413 436 427 2.39 2.34 2.34 2.59 2.81 2.73 2.62 169 386 430 437 Sodium mg/L 9610 10100 9710 50.5 52.0 52.4 53.5 54.0 56.2 55.7 4000 9100 10200 10300 Boron mg/L 4.32 4.82 4.49 0.0428 I

0.0425 I

0.043 I

0.037 I

0.0395 I

0.0376 I

0.0362 I

1.74 3.96 4.52 4.51 Strontium mg/L 7.01 7.24 7.14 0.518 0.512 0.514 0.536 0.567 0.555 0.544 3.92 6.55 7.1 7.42 Bromide mg/L 68.3 J

70.8 J

70.1 J

0.178 0.207 0.208 0.207 0.227 0.265 0.279 28.2 J

65.3 J

70.6 J

72.5 J

Chloride mg/L 19900 J

21200 J

20600 J

113 119 120 117 118 122 116 9050 J

18000 J

20900 J

21500 J

Fluoride mg/L 0.856 J

0.889 J

0.893 J

0.0636 I

0.0664 I

0.0741 I

0.0773 I

0.0786 I

0.0760 I

0.0744 I

0.345 J

0.757 J

0.835 J

0.807 J

Sulfate mg/L 2580 J

2730 J

2620 J

1.16 1.03 1.11 1.42 0.713 4.71 3.11 1040 J

2310 J

2670 J

2750 J

Total Ammonia mg/L as N 0.0426 I J 0.0415 I J 0.0408 I J 0.174 J

0.233 J

0.230 0.154 J

0.166 J

0.131 J

0.132 J

0.240 0.0780 0.0361 I

0.0260 U

Ammonium ion (NH4

+)

mg/L 0.0497 J

0.0494 J

0.04975 0.219 J

0.295 J

0.190 0.208 0.161 0.164 0.302 0.0970 0.0433 0.0300 U

Unionized NH3 mg/L 0.00480 J

0.00370 J

0.00271 0.00460 J

0.00424 J

0.00718 0.00512 0.00733 0.00578 0.00650 0.00313 0.00299 0

U Nitrate/Nitrite mg/L as N 0.00849 I

0.00540 U

0.00540 U

0.0200 J+ 0.0206 J+

0.0112 J

0.00827 I J+ 0.0109 J+

0.0125 J+

0.0315 J+

0.0267 J+

0.0102 J+

0.0176 J+ 0.00600 I J+

TKN mg/L 1.28 J

0.935 J

0.990 J

1.21 J

2.92 1.29 1.33 J

1.29 J

1.16 J

1.15 J

1.02 0.849 0.549 0.743 J

TN mg/L 1.29 J

0.94 J

1.00 J

1.23 J

2.94 J

1.34 J

1.30 J

1.17 J

1.18 J

1.05 J

0.86 J

0.57 J

0.75 J

ortho-Phosphate mg/L 0.00140 U

0.00140 U

0.00140 U 0.00140 U 0.00140 U 0.00140 U 0.00140 U 0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U

0.00440 U 0.00315 I J- 0.00831 I J- 0.00451 I

0.00289 I J- 0.00220 U J- 0.00220 U J- 0.00220 U J- 0.00220 U J- 0.00220 U J- 0.00220 U J- 0.00220 U J-Alkalinity mg/L 135 J

124 J

129 J

118 118 118 109 114 118 119 240 J

151 J

130 J

143 J

Bicarbonate Alkalinity mg/L as CaCO3 135 J

124 J

129 J

118 118 118 109 114 118 119 240 J

151 J

130 J

143 J

Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L Salinity 32.1 J

34.6 J

33.0 J

0.3 J

0.3 J

0.3 J

0.3 J

0.3 J

0.3 J

14.0 J

30.8 J

34.1 J

34.9 J

Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 091013-DUP is a duplicate of TPSWC-1B.

Sample 091113-DUP2 is a duplicate of TPSWC-5B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

TPSWC-1T TPSWC-1B 09/10/2013 09/10/2013 TPBBSW-3B 09/10/2013 09/10/2013 TPSWC-3B 09/10/2013 TPSWC-2T TPSWC-4B 09/11/2013 09/11/2013 TPSWC-4T 09/11/2013 TPSWC-5B TPBBSW-4B TPBBSW-5B 09/11/2013 09/12/2013 09/12/2013 TPSWC-5T TPSWC-2B 09/10/2013 TPSWC-3T 09/12/2013 091013-DUP 09/10/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-38 Table 3.2-2. Summary of Surface Water Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 25.82 25.83 31.89 30.53 32.30 29.00 31.59 30.01 39.56 34.86 34.35 33.58 33.09 pH SU 7.48 7.38 7.44 7.35 7.44 6.71 7.51 7.03 8.53 8.76 8.49 8.68 8.64 Dissolved Oxygen mg/L 1.49 J

0.94 J

5.52 4.58 5.77 0.42 5.86 1.36 4.68 4.92 6.07 6.72 5.77 Specific Conductance S/cm 750 758 3570 3565 3067 5929 2523 2520 88287 J

88270 J

84330 J

88135 J

87241 J

Turbidity NTU 0.25 0.77 0.60 1.65 0.60 16.17 0.38 0.33 81.66 78.94 76.18 76.24 79.45 Silica, dissolved mg/L 2.62 J-2.66 2.76 J-2.69 J-2.61 J-Calcium mg/L 460 88.5 86.3 109 107 121 195 100 120 783 J

791 J

778 823 830 J

Magnesium mg/L 1130 8.26 8.75 63.1 57.3 49.0 94.8 33.0 38.6 1920 J-1930 J-1920 2050 2090 J

Potassium mg/L 452 9.40 9.47 20.3 20.8 16.3 29.5 14.5 13.8 860 J+

855 J+

769 826 802 J

Sodium mg/L 10400 48.3 54.3 485 491 406 835 331 323 18600 J

18600 J

17200 18200 18200 J

Boron mg/L 4.51 0.0722 0.073 0.238 0.243 0.164 0.268 0.133 0.129 9.11 9.22 8.32 8.73 8.43 Strontium mg/L 7.42 0.943 0.939 1.2 1.21 1.23 2.15 1.21 1.18 16.5 16.4 15.4 16.4 15.8 Bromide mg/L 72.6 0.475 0.513 3.13 3.17 2.71 6.09 2.18 2.17 132 J

133 J

127 J

139 J

136 J

Chloride mg/L 21600 82.6 102 1000 1000 837 1760 676 660 37200 J

40100 J

37700 J

40200 J

38600 J

Fluoride mg/L 0.807 0.121 0.113 0.129 0.133 0.121 0.143 0.108 0.119 0.739 J-0.729 J

0.720 J-0.732 J-0.739 J

Sulfate mg/L 2750 53.0 48.5 93.3 93.0 73.8 156 56.9 56.2 5220 J

5090 J

4990 J

5330 J

5300 J

Total Ammonia mg/L as N 0.0260 U

0.0879 0.0793 0.0931 0.113 0.139 0.435 0.146 0.277 0.0907 J+

0.109 J

0.0952 0.0956 0.0781 Ammonium ion (NH4

+)

mg/L 0.111 0.101 0.117 0.143 0.174 0.557 0.182 0.353 0.0770 J+

0.0853 J

0.0918 0.0824 0.0700 Unionized NH3 mg/L 0.00191 0.00137 0.00278 0.00252 0.00427 0.00203 0.00500 0.00288 0.0374 J+

0.0518 J

0.0289 0.0382 0.0287 Nitrate/Nitrite mg/L as N 0.00753 I

0.0291 J+

0.0289 J+

0.0270 U

0.0270 U

0.0270 U

0.0270 U

0.0421 I

0.0297 I

0.0270 U

0.0270 U

0.0270 U

0.0270 U

0.0400 I

TKN mg/L 2.39 J

0.591 J

0.512 J

0.819 0.890 0.908 1.19 0.767 0.871 14.9 17.7 14.6 14.6 14.8 TN mg/L 0.62 J

0.54 J

0.85 0.92 0.94 1.22 0.81 0.90 14.93 17.73 14.63 14.63 14.84 ortho-Phosphate mg/L 0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00652 I

0.0162 0.00140 U

0.00748 I

0.00811 I

Total Phosphorus (P) mg/L 0.00220 U

0.00220 U J- 0.00220 U J- 0.00361 I

0.00334 I

0.00258 I

0.0101 0.00220 U

0.00277 I

0.0524 0.0460 0.0285 0.0429 0.0625 Alkalinity mg/L 142 192 194 247 251 214 312 206 223 124 J

128 J

132 J

127 J

127 J

Bicarbonate Alkalinity mg/L as CaCO3 142 192 194 247 251 214 312 206 223 76.5 J

39.0 J

70.8 J

28.4 J

27.4 J

Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.25 1.07 1.00 U

2.08 1.00 U

1.15 1.00 U

1.00 U

1.00 U

1.00 U

1.38 Total Dissolved Solids mg/L Salinity 0.4 J

0.4 J

1.9 J

1.9 J

1.6 J

3.2 1.3 J

1.3 J

61.9 J

62.2 J

59.0 J

62.2 J

61.5 J

Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 091013-DUP is a duplicate of TPSWC-1B.

Sample 091113-DUP2 is a duplicate of TPSWC-5B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

TPSWID-2B 091113-DUP2 09/11/2013 TPSWC-6B TPSWC-6T 09/09/2013 TPSWID-3T 09/05/2013 TPSWID-1B TPSWID-1T 09/05/2013 TPSWCCS-3B TPSWID-2T 09/05/2013 TPSWCCS-4T TPSWCCS-1B TPSWCCS-5T 09/09/2013 09/05/2013 09/05/2013 09/05/2013 TPSWID-3B 09/05/2013 09/05/2013 09/05/2013 TPSWCCS-2B 09/06/2013 09/05/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-39 Table 3.2-2. Summary of Surface Water Analytical Results from the September 2013 Sampling Event Parameter Units Temperature

°C 36.97 pH SU 8.55 Dissolved Oxygen mg/L 5.45 Specific Conductance S/cm 88914 J

Turbidity NTU 83.28 Silica, dissolved mg/L 2.53 J-0.0500 U

0.0500 U

Calcium mg/L 830 J

0.100 U

0.100 U

0.100 U

0.100 U

0.100 U

0.100 U

Magnesium mg/L 2050 J

0.0200 U

0.0267 I

0.0200 U

0.0200 U

0.0200 U

0.0200 U

Potassium mg/L 817 J

0.190 U

0.190 U

0.190 U

0.190 U

0.190 U

0.190 U

Sodium mg/L 18600 J

0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

0.310 U

Boron mg/L 8.90 0.0 U

0.01 U

0.010 U

0.01 U

0.01 U

0.01 U

Strontium mg/L 16.2 0.001 U

0.001 U

0.001 U

0.001 U

0.001 U

0.001 U

Bromide mg/L 138 J

0.0130 U

0.0130 U

0.0130 U

0.0130 U

0.0130 U

0.0130 U

Chloride mg/L 39000 J

0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

Fluoride mg/L 0.742 J-0.0240 U

0.0240 U

0.0240 U

0.0240 U

0.179 0.0240 U

Sulfate mg/L 5360 J

0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

0.250 U

Total Ammonia mg/L as N 0.0878 0.0260 U

0.0314 I

0.0260 U

0.0261 I

0.0262 I

Ammonium ion (NH4

+)

mg/L 0.0776 0.0319 Unionized NH3 mg/L 0.0334 0.00164 Nitrate/Nitrite mg/L as N 0.0270 U

0.0270 U

0.0270 U

0.00760 I

0.00540 U

0.00540 U

TKN mg/L 14.6 0.150 U

0.294 0.366 0.255 0.311 TN mg/L 14.63 0.32 ortho-Phosphate mg/L 0.00782 I

0.00140 U

0.00140 U

0.00140 U

0.00140 U

0.00140 U

Total Phosphorus (P) mg/L 0.0535 0.00220 U

0.00220 U

0.00220 U

0.00220 U

0.00220 U

Alkalinity mg/L 126 J

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Bicarbonate Alkalinity mg/L as CaCO3 55.3 J

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Sulfide mg/L 1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

1.00 U

Total Dissolved Solids mg/L 5.00 U

5.00 U

Salinity 62.7 J

Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 091013-DUP is a duplicate of TPSWC-1B.

Sample 091113-DUP2 is a duplicate of TPSWC-5B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

091213-FB1 09/12/2013 091013-FB1 090613-EB1 09/06/2013 TPSWCCS-7B 090913-FB1 09/09/2013 090513-FB1 09/05/2013 09/10/2013 091113-FB1 09/11/2013 09/05/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-40 Table 3.2-3. Summary of Surface Water Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 26.18 25.27 25.60 23.87 23.05 25.43 23.79 24.97 23.40 25.76 27.24 pH SU 7.99 7.94 7.71 7.39 7.18 7.65 7.32 7.91 7.52 7.19 6.89 Dissolved Oxygen mg/L 6.79 8.89 5.3 6.09 1.27 7.42 3.4 7.44 2.5 1.72 0.28 Specific Conductance S/cm 47355 47251 45990 648 778 619 639 636 1378 22129 28910 Turbidity NTU 1.15 0.54 0.55 0.85 1.24 0.38 0.64 0.68 3.36 1.08 7.36 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 9680 9550 9190 58.4 58.3 69.2 58.7 59.8 60.2 180 3800 5260 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 18200 18000 17300 115 115 139 119 120 122 364 7290 10400 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L Salinity 30.78 30.72 29.8 0.31 J

0.38 J

0.3 J

0.31 J

0.31 J

0.69 J

13.3 17.78 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

120513-DUP is a field duplicate of sample 120513-TPSWC-1T 121013-DUP is a field duplicate of sample 121013-TPSWCCS-5T KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

TPSWC-2B 12/5/2013 TPSWC-4T 12/10/2013 12/5/2013 12/5/2013 12/11/2013 TPSWC-3T TPSWC-3B TPBBSW-5B 12/5/2013 12/5/2013 TPSWC-4B TPSWC-1T TPBBSW-3B 12/11/2013 12/11/2013 12/5/2013 TPBBSW-4B 120513-Dup TPSWC-1B 12/5/2013 TPSWC-2T 12/10/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-41 Table 3.2-3. Summary of Surface Water Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 25.62 25.62 23.48 23.40 25.69 25.75 25.89 25.95 24.42 23.56 34.67 28.10 pH SU 7.86 7.75 7.21 7.27 7.78 7.78 7.55 7.18 7.63 7.68 8.13 8.2 Dissolved Oxygen mg/L 7.08 4.52 2.67 2.05 6.2 5.94 5.24 1.07 6.28 6.06 5.51 5.3 Specific Conductance S/cm 45693 47271 771 779 3289 3292 2718 3214 3947 5713 92911 87950 Turbidity NTU 0.51 0.41 0.29 0.23 0.4 0.27 0.22 1.24 6.34 0.18 61.99 56.87 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 9110 9260 54.6 57 464 465 370 444 571 888 19200 19200 Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 18000 18200 97.8 101 859 833 736 865 1120 1740 41600 37000 Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L Salinity 29.58 30.74 0.38 J

0.38 J

1.72 J

1.72 J

1.4 J

1.67 J

2.09 3.09 66.14 62.32 Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

120513-DUP is a field duplicate of sample 120513-TPSWC-1T 121013-DUP is a field duplicate of sample 121013-TPSWCCS-5T KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

12/10/2013 12/2/2013 12/2/2013 12/10/2013 12/10/2013 12/10/2013 12/2/2013 TPSWC-5B 12/10/2013 TPSWID-3T TPSWC-6B TPSWCCS-1B TPSWID-3B TPSWID-2T TPSWC-6T TPSWCCS-2B TPSWC-5T 12/10/2013 TPSWID-2B TPSWID-1T TPSWID-1B 12/10/2013 12/6/2013 12/6/2013

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-42 Table 3.2-3. Summary of Surface Water Analytical Results from the December 2013 Sampling Event Parameter Units Temperature

°C 30.98 29.15 28.67 34.84 pH SU 8.18 8.22 8.17 8.22 Dissolved Oxygen mg/L 6.15 6.12 4.93 7.66 Specific Conductance S/cm 90569 92534 92242 93266 J

Turbidity NTU 74.52 63.08 53.53 48.69 Silica, dissolved mg/L Calcium mg/L Magnesium mg/L Potassium mg/L Sodium mg/L 18400 19300 19600 19300 19600 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L Strontium mg/L Bromide mg/L Chloride mg/L 38800 39800 38100 39700 45900 J

0.25 U

0.25 U

0.25 U

0.297 I

0.313 I

Fluoride mg/L Sulfate mg/L Total Ammonia mg/L as N Ammonium ion (NH4

+)

mg/L Unionized NH3 mg/L Nitrate/Nitrite mg/L as N TKN mg/L TN mg/L ortho-Phosphate mg/L Total Phosphorus (P) mg/L Alkalinity mg/L Bicarbonate Alkalinity mg/L as CaCO3 Sulfide mg/L Total Dissolved Solids mg/L 5

U 5

U 5

U 5

U 64 Salinity 64.38 66.14 65.91 66.77 J

Tritium pCi/L (1)

NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

120513-DUP is a field duplicate of sample 120513-TPSWC-1T 121013-DUP is a field duplicate of sample 121013-TPSWCCS-5T KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

SU = Standard Unit(s).

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

N = Nitrogen.

TN = Total nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TPGW = Turkey Point Groundwater.

EB = Equipment blank.

NH4

+ = Ammonium ion.

U = Analyzed for but not detected at the reported value.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

12/11/2013 12/02/2013 12/05/2013 12/06/2013 12/10/2013 12/10/2013 12/10/2013 41618 12/10/2013 12/10/2013 121113-FB1 121013-Dup 121013-FB1 TPSWCCS-7B TPSWCCS-5T TPSWCCS-3B TPSWCCS-4T 120213-EB1 120513-FB1 120613-FB1

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-43 Table 3.2-4. Summary of Surface Water Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 25.15 24.80 25.00 26.27 25.10 25.63 25.49 25.04 25.03 25.62 26.03 pH SU 8.35 8.21 8.19 8.03 7.63 8.34 8.14 8.23 8.18 7.62 7.63 Dissolved Oxygen mg/L 6.95 7.03 6.00 7.54 4.70 7.77 6.95 7.94 7.70 3.38 3.24 Specific Conductance S/cm 51939 51356 48399 771 785 913 911 1279 1296 16204 19942 Turbidity NTU 0.65 0.51 0.75 1.86 3.77 1.33 2.24 2.26 2.31 0.56 6.99 Silica, dissolved mg/L Calcium mg/L 426 418 413 386 66.5 68.6 72.1 74 85.5 85.8 86.9 224 244 Magnesium mg/L 1150 1130 1110 1030 10.7 10.8 10.2 10.6 15 15.2 15.3 300 374 Potassium mg/L 435 428 425 385 3.6 3.74 3.93 4.04 5.11 5.07 5.15 110 141 Sodium mg/L 10900 10700 10900 10100 74.9 76.9 98 97.9 146 150 151 2860 3580 Boron mg/L 4.75 4.76 4.69 4.21 0.0508 0.0528 0.0472 I

0.0486 I

0.0682 0.0582 0.0568 1.16 1.49 Strontium mg/L 7.73 7.63 7.49 6.95 0.617 0.627 0.763 0.778 0.888 0.885 0.896 3.19 3.64 Bromide mg/L 69.4 68.3 68.3 63 0.294 0.308 0.452 0.457 0.763 0.798 0.799 18.4 23.3 Chloride mg/L 19400 20200 19000 17500 139 141 185 183 290 301 302 5240 6560 Fluoride mg/L 0.867 0.871 0.889 0.85 J-0.0722 I

0.0713 I

0.0774 I

0.0777 I

0.0857 I

0.085 I

0.0777 I

0.333 0.403 Sulfate mg/L 2850 2770 2770 2550 8.03 J

8.91 J

13.1 13 24.3 19.6 19.6 681 881 Total Ammonia mg/L as N 0.163 J

0.111 J

0.0691 J

0.026 U

0.303 0.439 0.34 0.186 0.227 0.231 J

0.404 J

0.386 0.596 Ammonium ion (NH4

+)

mg/L 0.186 J

0.131 J

0.05 U

0.365 0.551 0.387 0.221 0.266 0.273 J

0.484 0.747 Unionized NH3 mg/L 0.0226 J

0.0112 J

1.7E-05 U

0.023 0.0127 0.0475 0.017 0.0244 0.0223 J

0.0113 0.0184 Nitrate/Nitrite mg/L as N 0.039 I

0.0478 I

0.027 U

0.027 U

0.0646 J

0.027 U

0.027 U

0.027 U

0.027 U

0.027 U

0.027 U

0.103 0.0996 TKN mg/L 0.554 0.544 0.536 0.533 0.701 0.871 0.702 0.815 0.686 0.757 0.672 1.05 0.952 TN mg/L 0.593 0.592 0.563 0.560 0.766 J

0.898 0.729 0.842 0.713 0.784 0.699 1.15 1.05 ortho-Phosphate mg/L 0.0117 J

0.0014 U

0.0014 U

0.0014 U

0.0019 I

0.0014 U

0.00241 I

0.00159 I

0.0014 U

0.00187 I

0.00258 I

0.0014 U

0.0014 U

Total Phosphorus (P) mg/L 0.0022 UJ 0.0022 U

0.0022 U

0.0113 I

0.0122 0.0103 0.0184 I

0.00443 I

0.00566 I

0.00565 I

0.00695 I

0.00283 I

0.003 I

Alkalinity mg/L 134 138 139 150 167 171 159 153 182 178 175 248 251 Bicarbonate Alkalinity mg/L as CaCO3 134 138 139 150 167 171 159 153 178 178 175 248 251 Sulfide mg/L 1

U Q 1

U Q 1

U Q 1

U Q 1

U 1

U 1

U 1

U 1

U 1

U 1

U 1

U 1

U Salinity 34.2 33.7 31.6 0.4 J

0.4 J

0.5 J

0.5 J

0.6 J

0.6 J

9.5 11.9 Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 031214-DUP is a duplicate of BBSW-4B.

Sample 030714-DUP2 is a duplicate of TPSWC-3B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL. pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

TPBBSW-5B TPSWC-1T 03/07/2014 03/12/2014 TPBBSW-3B 03/07/2014 03/07/2014 TPSWC-3B 03/07/2014 TPSWC-2T TPSWC-4B 03/04/2014 TPSWC-4T 03/04/2014 TPBBSW-4B 031214-DUP 03/12/2014 03/12/2014 TPSWC-2B 03/07/2014 03/12/2014 TPSWC-1B 03/07/2014 030714-DUP 03/07/2014 TPSWC-3T

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-44 Table 3.2-4. Summary of Surface Water Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 26.36 25.33 23.52 23.39 28.48 28.00 27.46 25.84 27.37 25.65 37.43 34.53 pH SU 7.85 7.96 7.32 7.27 7.60 6.90 7.28 7.22 7.46 7.35 8.42 8.79 Dissolved Oxygen mg/L 3.32 3.77 2.25 2.24 5.73 0.39 4.72 3.11 7.83 3.83 8.30 6.85 Specific Conductance S/cm 51652 51703 716 721 4851 10656 3226 3967 3304 3291 109243 107890 J

Turbidity NTU 0.28 1.03 0.27 0.37 0.75 39.79 0.53 1.09 0.51 0.44 106.30 93.91 Silica, dissolved mg/L 5.64 J

5.47 J

Calcium mg/L 429 425 77.6 78.9 147 186 139 151 141 138 1050 1020 J

Magnesium mg/L 1200 1200 8.55 8.73 82.5 186 48.2 61.2 47.8 46.2 2650 2440 J

Potassium mg/L 420 415 11 11.2 30.7 77 18.1 22.1 18.2 17.6 1000 1010 J

Sodium mg/L 10400 10500 50.1 51.5 710 1760 430 547 441 430 24500 24100 J

Boron mg/L 4.59 4.57 0.0785 0.0813 0.353 0.812 0.181 0.225 0.183 0.167 11.7 12 Strontium mg/L 7.6 7.5 0.973 0.983 1.71 2.52 1.52 1.71 1.49 1.44 21.2 21.2 Bromide mg/L 67.1 67.2 0.488 0.491 4.23 10.9 2.81 3.52 2.9 2.89 175 177 J

Chloride mg/L 19500 19300 89.1 92.5 1330 3270 827 1060 853 858 46000 48900 J

Fluoride mg/L 0.932 0.956 0.121 0.12 0.154 0.203 0.12 0.128 0.116 0.109 0.845 J

0.906 J

Sulfate mg/L 2780 2770 66.3 67.4 145 389 84.4 108 79.7 78.2 7740 7130 J

Total Ammonia mg/L as N 0.303 0.382 0.178 0.285 0.207 0.713 0.497 0.0272 I

0.18 0.275 0.152 J

0.234 J

Ammonium ion (NH4

+)

mg/L 0.373 0.466 0.226 0.363 0.259 0.912 0.631 0.05 U

0.227 0.349 0.145 J

0.18 J

Unionized NH3 mg/L 0.0156 0.0234 0.00229 0.00324 0.00706 0.0048 0.00768 0.000328 0.00416 0.0044 0.0476 J

0.114 J

Nitrate/Nitrite mg/L as N 0.0289 I

0.027 U

0.029 I

0.037 I

0.0816 J

0.0433 IJ 0.0835 J

0.132 J

0.202 J

0.168 J

0.0389 IJ 0.0445 IJ TKN mg/L 0.385 I

0.396 I

0.321 I

0.3 U

0.874 J

1.72 J

0.738 J

0.768 J

0.697 J

0.668 J

10.6 J

0.3 U

TN mg/L 0.414 0.423 0.350 0.337 0.956 J

1.76 J

0.822 J

0.900 J

0.899 J

0.836 J

10.6 J

0.340 J

ortho-Phosphate mg/L 0.0014 U

0.0014 U

0.00178 IJ 0.00211 IJ 0.0169 IJ 0.0166 IJ 0.014 UJ 0.014 UJ 0.014 UJ 0.014 UJ 0.014 U

0.0014 U

Total Phosphorus (P) mg/L 0.00368 I

0.00594 I

0.0022 U

0.0022 U

0.00689 IJ 0.0324 0.00229 IJ 0.00245 IJ 0.00229 IJ 0.00285 IJ 0.0583 0.00752 I

Alkalinity mg/L 153 147 161 158 344 448 280 298 264 271 151 146 J

Bicarbonate Alkalinity mg/L as CaCO3 153 147 161 158 344 448 280 298 264 271 54.3 19.3 J

Sulfide mg/L 1

U Q 1

U Q 1

U 1

U 1

U 4.5 1

U 1

U 1

U 1

U 1

U Q 1

U Q Salinity 33.9 34.0 0.4 J

0.4 J

2.6 6.0 1.7 J

2.1 1.7 J

1.7 J

80.1 79.1 J

Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 031214-DUP is a duplicate of BBSW-4B.

Sample 030714-DUP2 is a duplicate of TPSWC-3B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s). U = Analyzed for but not detected at the reported value.

TPSWID-3T TPSWC-6T 03/10/2014 TPSWID-1T TPSWC-6B 03/10/2014 03/04/2014 TPSWC-5B 03/04/2014 TPSWC-5T TPSWID-3B 03/03/2014 TPSWID-2T TPSWID-1B 03/03/2014 TPSWID-2B TPSWCCS-2B 03/03/2014 03/03/2014 03/03/2014 03/03/2014 TPSWCCS-1B 03/03/2014 03/05/2014

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-45 Table 3.2-4. Summary of Surface Water Analytical Results from the March 2014 Sampling Event Parameter Units Temperature

°C 32.26 29.23 29.22 36.76 pH SU 8.39 8.45 8.38 8.56 Dissolved Oxygen mg/L 8.79 7.54 8.75 12.30 Specific Conductance S/cm 101963 107858 J

107648 J

101912 Turbidity NTU 102.50 90.78 103.30 261.10 Silica, dissolved mg/L 5.33 J-5.67 J

5.49 J

5.44 J

0.05 U

0.05 U

0.05 U

0.05 U

0.05 U

Calcium mg/L 990 1050 J

1050 J

1010 0.1 U

0.1 U

0.1 U

0.1 U

0.1 U

Magnesium mg/L 2440 2640 J

2620 J

2510 0.02 U

0.02 U

0.02 U

0.02 U

0.02 U

Potassium mg/L 952 993 J

994 J

933 0.19 U

0.19 U

0.19 U

0.19 U

0.19 U

Sodium mg/L 23200 23600 J

23500 J

22400 0.31 U

0.31 U

0.31 U

0.31 U

0.31 U

Boron mg/L 10.6 11.5 11.5 11.1 0.01 U

0.01 U

0.01 U

0.01 U

0.01 U

Strontium mg/L 20 21.2 20.9 20.3 0.001 U

0.001 U

0.001 U

0.001 U

0.001 U

Bromide mg/L 148 168 J

166 J

171 0.013 U

0.013 U

0.013 U

0.013 U

0.013 U

Chloride mg/L 41600 47800 J

48500 J

42300 0.25 U

0.476 I

0.364 I

0.25 U

0.25 U

Fluoride mg/L 0.814 J

0.838 J

0.841 J

0.821 J

0.024 U

0.024 U

0.024 U

0.024 U

0.024 U

Sulfate mg/L 6470 7290 J

7270 J

7300 0.766 0.25 U

1.11 0.304 I

0.250 U

Total Ammonia mg/L as N 0.114 J

0.132 J

0.0842 J

0.103 J

0.026 U

0.026 U

0.026 U

0.026 U

0.026 U

Ammonium ion (NH4

+)

mg/L 0.119 J

0.14 J

0.0915 J

0.0907 J

Unionized NH3 mg/L 0.0259 J

0.0284 J

0.0158 J

0.0394 J

Nitrate/Nitrite mg/L as N 0.027 UJ 0.0499 IJ 0.0416 IJI 0.0385 IJ 0.0331 I

0.027 U

0.0555 0.027 U

0.027 U

TKN mg/L 9.74 J

10.7 J

10.5 J

13.3 J

6.55 0.3 U

0.3 U

0.3 U

0.3 U

TN mg/L 9.77 J

10.7 J

10.5 J

13.3 J

ortho-Phosphate mg/L 0.014 U?

0.014 U

0.014 U

0.014 U

0.00325 I

0.00324 I

0.0014 U

0.00399 I

0.00293 I

Total Phosphorus (P) mg/L 0.0894 0.0282 0.0585 0.0425 0.0022 U

0.0022 U

0.0022 U

0.0022 U

0.0022 U

Alkalinity mg/L 158 150 J

147 J

169 1.41 1

U 1

U 1

U 1

U Bicarbonate Alkalinity mg/L as CaCO3 98.4 94.9 J

102 J

77 1.41 1

U 1

U 1

U 1

U Sulfide mg/L 1

U Q 1

U Q 1

U Q 1

U Q 1

U 1

U 1

U 1

U 1

U Salinity 74.0 79.4 J

79.3 J

73.7 Tritium pCi/L NOTES:

Laboratory anion and cation results are reported with 3 digits although only the first 2 are significant figures.

  • PSS-78 salinity is unitless.

Sample 031214-DUP is a duplicate of BBSW-4B.

Sample 030714-DUP2 is a duplicate of TPSWC-3B.

KEY:

°C = Degrees Celsius.

I = Value between the MDL and PQL.pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter J = Estimated (+/- indicate bias).

Q = Holding time exceeded.

= sigma (Standard Deviation).

mg/L = Milligram(s) per liter.

SU = Standard Unit(s).

CaCO3 = Calcium carbonate.

N = Nitrogen.

TKN = Total Kjeldahl nitrogen.

DUP = Duplicate.

NH3 = Ammonia.

TN = Total nitrogen.

EB = Equipment blank.

NH4

+ = Ammonium ion.

TPGW = Turkey Point Groundwater.

FB = Field blank.

NTU = Nephelometric Turbidity Units(s).

U = Analyzed for but not detected at the reported value.

031214-FB1 03/12/2014 TPSWCCS-7B TPSWCCS-3B 03/03/2014 030314-EB1 TPSWCCS-4T TPSWCCS-5T 03/03/2014 03/03/2014 03/03/2014 03/03/2014 030414-FB1 03/04/2014 030714-FB1 03/07/2014 031014-FB1 03/10/2014

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-46 Table 3.2-5. Range of Ion and Nutrient Concentrations in Surface Water Pre-Uprate Parameter Units Min Max Avg Stdev Min Max Avg Stdev Min Max Avg Stdev Min Max Avg Stdev Temperature

°C 24.80 29.47 27.08 1.88 17.02 31.91 26.50 5.20 23.56 32.30 28.02 2.37 23.48 31.97 28.15 2.86 pH SU 7.68 8.35 7.98 0.21 7.70 8.65 8.29 0.20 6.71 8.06 7.46 0.33 6.86 8.52 7.56 0.41 Dissolved Oxygen mg/L 4.21 8.89 5.89 1.32 4.00 9.22 6.50 1.64 0.39 7.83 4.47 2.17 0.04 7.44 3.10 2.54 Specific Conductance S/cm 45990 53783 49733 2682 30586 66855 50200 8419 2520 13700 4495 2615 2076 66251 14066 17711 Turbidity NTU 0.51 1.94 0.91 0.41 0.44 11.97 2.79 2.77 0.18 39.79 3.96 9.19 0.34 47.92 4.24 7.91 Calcium mg/L 386 426 407 15 260 540 423 63 100 195 138 30 87 610 211 138 Magnesium mg/L 1030 1150 1100 43 650 1700 1284 262 33 186 67 41 28 1700 310 447 Potassium mg/L 385 436 421 19 260 590 417 86 14 77 25 17 12 560 104 144 Sodium mg/L 8610 10900 9963 703 5400 14000 10349 2066 323 2300 659 462 290 14000 2577 3638 Boron mg/L 4.21 4.82 4.56 0.26 2.50 5.50 4.41 0.81 0.13 0.81 0.26 0.19 0.10 5.30 1.01 1.40 Strontium mg/L 6.95 7.73 7.28 0.32 4.30 9.90 7.47 1.35 1.18 2.52 1.55 0.42 1.00 11.00 2.96 2.60 Bromide mg/L 63.0 70.8 68.3 2.8 32.0 100.0 67.4 17.1 2.2 10.9 3.9 2.4 1.5 85.0 15.9 21.1 Chloride mg/L 17000 21300 19292 1609 11000 28000 19171 4119 660 4300 1279 855 110 27000 4790 6969 Fluoride mg/L 0.850 0.893 0.871 0.017 0.100 0.960 0.562 0.241 0.108 0.203 0.132 0.026 0.027 3.200 0.311 0.480 Sulfate mg/L 2550 2850 2683 118 1200 3700 2557 509 56 389 118 91 30 2900 520 714 Total Ammonia mg/L as N 0.0 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.7 0.3 0.2 0.2 1.9 0.5 0.5 Ammonium ion (NH4

+)

mg/L 0.0 0.2 0.1 0.1 0.0 0.2 0.1 0.0 0.1 0.9 0.3 0.3 0.2 2.4 0.6 0.6 Unionized NH3 mg/L 0.000017 0.0226 0.0075 0.0083 0.0039 0.0474 0.0176 0.0138 0.0003 0.0077 0.0040 0.0021 0.0025 0.0457 0.0174 0.0140 Nitrate/Nitrite mg/L as N 0.0054 0.0478 0.0222 0.0185 0.0047 0.0600 0.0235 0.0154 0.0270 0.2020 0.0742 0.0614 0.0047 0.1200 0.0316 0.0395 Total Kjedahl Nitrogen mg/L 0.5330 1.2800 0.8060 0.3104 0.1100 0.6300 0.3167 0.1194 0.6680 1.7200 0.9092 0.2892 0.7800 2.4000 1.1289 0.4467 Total Nitrogen mg/L 0.5600 1.2885 0.8282 0.2951 0.2500 0.6500 0.3500 0.1056 0.8091 1.7633 0.9834 0.2677 0.7883 2.4000 1.2028 0.4513 ortho-Phosphate mg/L 0.0014 0.0117 0.0031 0.0042 0.0014 0.0110 0.0041 0.0031 0.0014 0.0169 0.0082 0.0071 0.0014 0.0410 0.0172 0.0171 Total Phosphorus mg/L 0.0022 0.0113 0.0041 0.0036 0.0160 0.0520 0.0261 0.0144 0.0022 0.0324 0.0061 0.0086 0.0044 0.0400 0.0106 0.0096 Alkalinity mg/L 124 150 135 9

58 180 125 28 206 448 280 67 120 400 235 60 Bicarbonate Alkalinity mg/L as CaCO3 124 150 135 9

57 180 123 30 206 448 280 67 120 400 235 60 Sulfide mg/L 1.0 1.0 1.0 0.0 1.0 1.0 1.0 0.0 1.0 4.5 1.4 1.0 1.0 13.0 2.0 2.7 Total Dissolved Solids mg/L Salinity (PSS-78) 29.8 35.4 32.5 2.0 18.9 45.3 32.9 6.1 1.3 7.9 2.4 1.5 1.0 44.8 8.7 11.8 Tritium pCi/L (1)

NOTES:

  • PSS-78 salinity is unitless.

KEY:

°C = Degrees Celsius.

Min = Minimum.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

N = Nitrogen.

SU = Standard Unit(s).

= sigma (Standard Deviation).

NH3 = Ammonia.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH4

+ = Ammonium ion.

TN = Total nitrogen.

Max = Maximum.

NTU = Nephelometric Turbidity Units(s).

TPGW = Turkey Point Groundwater.

mg/L = Milligram(s) per liter.

Interceptor Ditch Biscayne Bay Post-Uprate Post-Uprate Pre-Uprate

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-47 Table 3.2-5. Range of Ion and Nutrient Concentrations in Surface Water Parameter Units Min Max Avg Stdev Min Max Avg Stdev Min Max Avg Stdev Min Max Avg Stdev Temperature

°C 23.05 30.71 26.59 2.18 19.64 33.11 27.65 3.72 28.10 40.33 33.77 3.46 19.43 40.31 30.26 5.61 pH SU 6.89 8.34 7.57 0.34 6.53 8.83 7.76 0.42 8.13 8.87 8.50 0.23 7.91 8.94 8.32 0.26 Dissolved Oxygen mg/L 0.19 7.94 4.05 2.25 0.22 9.44 4.56 2.51 4.28 12.30 6.52 1.83 2.05 8.08 5.39 1.49 Specific Conductance S/cm 402 55524 14173 20724 422 63421 15880 22785 74015 109243 90037 11519 68344 88902 80787 5067 Turbidity NTU 0.23 9.43 1.72 2.24 0.34 107.80 6.51 13.75 28.15 261.10 74.83 46.60 3.18 17.27 7.93 3.46 Calcium mg/L 50 443 163 147 44 560 189 175 778 1050 917 119 570 950 753 79 Magnesium mg/L 6

1200 288 461 6

1700 379 586 1920 2650 2272 303 1800 3000 2243 251 Potassium mg/L 2

437 108 169 3

540 126 190 769 1010 901 88 560 870 706 82 Sodium mg/L 31 11500 2715 4143 27 13000 3052 4668 15300 24500 19104 3022 15000 22000 17700 1645 Boron mg/L 0.04 4.59 1.14 1.79 0.03 5.70 1.29 1.97 8.32 12.00 10.09 1.43 6.20 11.00 7.61 0.85 Strontium mg/L 0.51 7.60 2.44 2.70 0.42 9.60 2.87 3.21 15.40 21.20 18.46 2.49 12.00 18.00 14.20 1.25 Bromide mg/L 0.2 72.5 17.5 27.9 0.0 110.0 20.8 33.1 127.0 177.0 150.8 19.0 52.0 270.0 118.1 28.1 Chloride mg/L 54 22900 5382 8236 39 28000 6089 9337 29800 48900 39008 5807 27000 39000 34114 2902 Fluoride mg/L 0.064 0.956 0.281 0.318 0.020 2.000 0.340 0.468 0.720 0.906 0.789 0.062 0.020 6.500 1.181 1.562 Sulfate mg/L 1

2780 676 1080 2

4000 783 1220 4990 7740 6208 1078 1300 5200 4270 732 Total Ammonia mg/L as N 0.0 0.6 0.2 0.1 0.1 0.4 0.2 0.1 0.1 0.2 0.1 0.0 0.1 0.5 0.2 0.1 Ammonium ion (NH4

+)

mg/L 0.0 0.7 0.3 0.2 0.1 0.5 0.2 0.1 0.07 0.2 0.1 0.0 0.1 0.7 0.2 0.1 Unionized NH3 mg/L 0.000017 0.0475 0.0113 0.0110 0.0026 0.0316 0.0109 0.0071 0.0158 0.1140 0.0408 0.0250 0.0000 0.0568 0.0245 0.0115 Nitrate/Nitrite mg/L as N 0.0060 0.1030 0.0311 0.0246 0.0047 0.5500 0.0813 0.1497 0.0270 0.0499 0.0346 0.0085 0.0047 0.1300 0.0377 0.0322 Total Kjedahl Nitrogen mg/L 0.3000 2.9200 0.8858 0.5293 0.4700 1.4000 0.9806 0.2890 9.7400 17.7000 13.2764 2.5258 1.5000 2.5000 2.0067 0.2935 Total Nitrogen mg/L 0.3370 2.9406 0.9169 0.5278 0.4700 1.6000 1.0589 0.3114 9.7670 17.7270 13.3101 2.5214 0.8700 3.0000 2.0541 0.4078 ortho-Phosphate mg/L 0.0014 0.0024 0.0015 0.0003 0.0014 0.0049 0.0021 0.0014 0.0014 0.0162 0.0099 0.0052 0.0014 0.0870 0.0137 0.0285 Total Phosphorus mg/L 0.0022 0.0184 0.0046 0.0040 0.0044 0.0420 0.0106 0.0108 0.0075 0.0894 0.0475 0.0206 0.0044 0.0730 0.0276 0.0167 Alkalinity mg/L 109 251 161 41 42 270 157 49 124 169 140 15 73 190 143 23 Bicarbonate Alkalinity mg/L as CaCO3 109 251 161 41 42 270 157 49 19 102 62 29 73 190 135 27 Sulfide mg/L 1.0 1.0 1.0 0.0 1.0 1.1 1.0 0.0 1.0 1.4 1.0 0.1 1.0 1.6 1.0 0.1 Total Dissolved Solids mg/L Salinity (PSS-78) 0.2 36.8 9.1 13.6 0.2 42.6 10.2 15.1 50.8 80.1 63.9 9.7 46.6 67.1 56.8 4.3 Tritium pCi/L (1)

NOTES:

  • PSS-78 salinity is unitless.

KEY:

°C = Degrees Celsius.

Min = Minimum.

pCi/L = PicoCuries per liter.

S/cm = MicroSiemen(s) per centimeter.

N = Nitrogen.

SU = Standard Unit(s).

= sigma (Standard Deviation).

NH3 = Ammonia.

TKN = Total Kjeldahl nitrogen.

CaCO3 = Calcium carbonate.

NH4

+ = Ammonium ion.

TN = Total nitrogen.

Max = Maximum.

NTU = Nephelometric Turbidity Units(s).

TPGW = Turkey Point Groundwater.

mg/L = Milligram(s) per liter.

Cooling Canals L-31E Post-Uprate Post-Uprate Pre-Uprate Pre-Uprate

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 FIGURES

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-49 Figure 3.1-1. Typical Groundwater Field Sampling Setup.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-50 Figure 3.1-2. Range (pre-Uprate) and Results (post-Uprate) of Quarterly Groundwater Samples for Chloride (mg/L).

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-51 Figure 3.1-3. Range (pre-Uprate) and Results (post-Uprate) of Quarterly Groundwater Samples for Sodium (mg/L).

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-52 Figure 3.1-4. Range (pre-Uprate) and Results (post-Uprate) of Quarterly Groundwater Samples for Specific Conductance

(µS/cm).

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-53 Figure 3.1-5. Locations of Aquifer Cross Sections for Groundwater Chloride Concentrations.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-54 Figure 3.1-6. Cross Section A-A Showing Quarterly Groundwater Chloride Concentrations from June/July 2010 through June 2014.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 3 3-55 Figure 3.1-7. Cross Section B-B Showing Quarterly Groundwater Chloride Concentrations from June/July 2010 through June 2014.