MONTHYEARML13120A1052013-04-26026 April 2013 Response to Request for Information: Near-Term Task Force Recommendation 2.1, Seismic Reevaluation Project stage: Response to RAI ML13259A0442013-09-12012 September 2013 Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident - 1.5 Year Response for CEUS Sites Project stage: Response to RAI ML14051A1072014-02-12012 February 2014 Update to Response to NRC Request for Information Pursuant to 10CFR50.54(f) Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident - 1.5 Year Response for CEUS Sites Project stage: Response to RAI ML14125A3672014-03-12012 March 2014 Drawing LRA-M-2032-1, Rev. Aj, Sump Pump Diagram Radwaste System Project stage: Request BVY 14-019, Notification of Revised Regulatory Commitments Associated with Request for Information Per 10 CFR50.54(f) Regarding Recommendations 2.1, 2.3, & 9.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident .2014-03-12012 March 2014 Notification of Revised Regulatory Commitments Associated with Request for Information Per 10 CFR50.54(f) Regarding Recommendations 2.1, 2.3, & 9.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident . Project stage: Request SBK-L-14052, NextEra Energy Seabrook, LLC Seismic Hazard and Screening Report (CEUS Sites) Response to NRC Request for Information Per 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-2014-03-27027 March 2014 NextEra Energy Seabrook, LLC Seismic Hazard and Screening Report (CEUS Sites) Response to NRC Request for Information Per 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ich Project stage: Response to RAI NL-14-0343, Seismic Hazard and Screening Report for CEUS Sites2014-03-31031 March 2014 Seismic Hazard and Screening Report for CEUS Sites Project stage: Request NRC-14-0017, DTE Electric Companys Seismic Hazard and Screening Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accide2014-03-31031 March 2014 DTE Electric Companys Seismic Hazard and Screening Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident Project stage: Response to RAI NRC 2014-0024, NextEra Energy Point Beach, LLC - Seismic Hazard and Screening Report (CEUS Sites), Response NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the F2014-03-31031 March 2014 NextEra Energy Point Beach, LLC - Seismic Hazard and Screening Report (CEUS Sites), Response NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukush Project stage: Request NL-14-0344, Seismic Hazard and Screening Report for CEUS Sites2014-03-31031 March 2014 Seismic Hazard and Screening Report for CEUS Sites Project stage: Request CNL-14-038, Tennessee Valley Authoritys Seismic Hazard & Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Recommendation 2.1 of Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Acci2014-03-31031 March 2014 Tennessee Valley Authoritys Seismic Hazard & Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Recommendation 2.1 of Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accide Project stage: Response to RAI RNP-RA/14-0013, Seismic Hazard Evaluation, Response to NRC 10 CFR 50.54(f) Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f)Regarding Recommendations 2.1, 2.3 and 9.3 of the Near-Term Task Force Review of2014-03-31031 March 2014 Seismic Hazard Evaluation, Response to NRC 10 CFR 50.54(f) Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f)Regarding Recommendations 2.1, 2.3 and 9.3 of the Near-Term Task Force Review of Project stage: Request ML14099A1962014-03-31031 March 2014 Constellation Energy Nuclear Group, LLC - Seismic Hazard and Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Project stage: Response to RAI ML14092A4162014-03-31031 March 2014 Response to March 12, 2012 Information Request Seismic Hazard and Screening Report (CEUS Sites)For Recommendation 2.1 Project stage: Request L-MT-14-045, Seismic Hazard and Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10CFR50.54(f), Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident2014-05-14014 May 2014 Seismic Hazard and Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10CFR50.54(f), Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident Project stage: Response to RAI RA-14-071, Supplemental Information Regarding Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites) - Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Tas2014-08-21021 August 2014 Supplemental Information Regarding Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites) - Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Project stage: Supplement ML14307B7072014-12-10010 December 2014 Supplemental Information Related to Development of Seismic Risk Evaluations for Information Request Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-T Project stage: Other ML14349A4952014-12-10010 December 2014 Proposed Change to Technical Specifications Concerning the Safety Limit Minimum Critical Power Ratio Project stage: Request ML15034A1062015-02-0303 February 2015 Supplemental Information Needed for Acceptance of Requested Licensing Action Regarding the Safety Limit Minimum Critical Power Ratio License Amendment Request Project stage: Acceptance Review ML15050A2452015-02-13013 February 2015 Response to Request for Supplemental Information Needed for Acceptance of Requested Licensing Action Regarding the Safety Limit Minimum Critical Power Ratio License Amendment Request Project stage: Supplement ML15051A2832015-02-19019 February 2015 NRR E-mail Capture - Pilgrim - Acceptance Review Safety Limit Minimum Critical Power Ratio (MF5431) Project stage: Acceptance Review ML15051A0232015-02-25025 February 2015 Request for Withholding Information from Public Disclosure (Tac No. MF5431) Project stage: Withholding Request Acceptance ML15051A0322015-02-25025 February 2015 Request for Additional Information Regarding the Safety Limit Minimum Critical Power Ratio License Amendment Request Project stage: RAI NRC-2015-0053, Federal Register Notice - License Amendment Application; Opportunity to Comment, Request a Hearing, and Petition for Leave to Intervene; Order for Entergy Nuclear Operations, Inc. Pilgrim Nuclear Power Station2015-03-0606 March 2015 Federal Register Notice - License Amendment Application; Opportunity to Comment, Request a Hearing, and Petition for Leave to Intervene; Order for Entergy Nuclear Operations, Inc. Pilgrim Nuclear Power Station Project stage: Other ML15051A0242015-03-0606 March 2015 Individual Notice of Consideration of Issuance of Amendment to Facility Operating License, Proposed No Significant Hazards Consideration Determination & Opportunity for a Hearing & Order Imposing Procedures for Document Access (MF5431) Project stage: Other ML15051A0272015-03-0606 March 2015 Federal Register Notice - License Amendment Application; Opportunity to Comment, Request a Hearing, and Petition for Leave to Intervene; Order for Entergy Nuclear Operations, Inc. Pilgrim Nuclear Power Station Project stage: Other ML15075A0332015-03-11011 March 2015 Response to NRC Request for Additional Information Regarding the Safety Limit Minimum Critical Power Ratio License Amendment Request Project stage: Response to RAI ML15037A5232015-03-27027 March 2015 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML15114A0212015-05-0606 May 2015 Issuance of Amendment Regarding the Minimum Critical Power Ratio License Amendment Request Project stage: Approval 2014-08-21
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. John Dent, Jr.
Site Vice President Entergy Nuclear Operations, Inc.
Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360-5508 February 25, 2015
SUBJECT:
PILGRIM NUCLEAR POWER PLANT - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE SAFETY LIMIT MINIMUM CRITICAL POWER RATIO LICENSE AMENDMENT REQUEST (TAC NO. MF5431)
Dear Mr. Dent:
By letter dated December 10, 2014, as supplemented by letter dated February 13, 2015, Entergy Nuclear Operations, Inc. submitted a license amendment request that would revise the Safety Limit Minimum Critical Power Ratio from~ 1.08 to~ 1.10 for two recirculation loop operation and from ~ 1.11 to~ 1.12 for single loop operation for Pilgrim Nuclear Power Station.
The Nuclear Regulatory Commission (NRC) staff is reviewing the application and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). The NRC staff is requesting a response to the RAI within 14 days of February 23, 2015 in an effort to expedite the review.
If you have any questions regarding this matter, please contact me at (301) 415-1016.
Docket No. 50-293
Enclosure:
RAI cc w/encl: Distribution via Listserv Sincerely, adiyah S. Morgan, Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
REQUEST FOR ADDITIONAL INFORMATION REGARDING THE SAFETY LIMIT MINIMUM CRITICAL POWER RATIO LICENSE AMENDMENT REQUEST ENTERGY NUCLEAR GENERATION COMPANY ENTERGY NUCLEAR OPERATIONS, INC.
PILGRIM NUCLEAR POWER STATION DOCKET NO. 50-293 By letter dated December 10, 2014 (Agencywide Document Access and Management System (ADAMS) Accession No. ML14349A495), as supplemented by letter dated February 13, 2015 (ADAMS Accession No. ML15050A245), Entergy Nuclear Operations, Inc. submitted a license amendment request that would revise the Safety Limit Minimum Critical Power Ratio from.:::_
- 1. 08 to.:::_ 1.10 for two recirculation loop operation and from.:::_ 1.11 to.:::_ 1.12 for single loop operation for Pilgrim Nuclear Power Station (Pilgrim).
In order to complete its review, the Nuclear Regulatory Commission staff requests further information on the following items:
- 1.
Provide the differences in design and geometrical considerations between Global Nuclear Fuel - 2 and General Electric - 14.
- 2.
- a.
Discuss the methodology and the scheme used during Pilgrim Cycles 20 and 21 for core reloads. Is there a noticeable change in the core radial and axial power shapes between cycles 20 and 21 reloads?
- b.
For the initial core loadings of the Pilgrim Cycles 20 and 21 specify the fuel type, number of fresh, once-burned, twice-, and thrice-burned fuel.
Enclosure
February 25, 2015 Mr. John Dent, Jr.
Site Vice President Entergy Nuclear Operations, Inc.
Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360-5508
SUBJECT:
PILGRIM NUCLEAR POWER PLANT - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE SAFETY LIMIT MINIMUM CRITICAL POWER RATIO LICENSE AMENDMENT REQUEST (TAC NO. MF5431)
Dear Mr. Dent:
By letter dated December 10, 2014, as supplemented by letter dated February 13, 2015, Entergy Nuclear Operations, Inc. submitted a license amendment request that would revise the Safety Limit Minimum Critical Power Ratio from > 1.08 to > 1.10 for two recirculation loop operation and from > 1.11 to > 1.12 for single loop operation for Pilgrim Nuclear Power Station.
The Nuclear Regulatory Commission (NRC) staff is reviewing the application and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). The NRC staff is requesting a response to the RAI within 14 days of February 23, 2015 in an effort to expedite the review.
If you have any questions regarding this matter, please contact me at (301) 415-1016.
Docket No. 50-293
Enclosure:
RAI cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPLl-1 R/F RidsNrrDorlDpr M. Chernoff RidsNrrDorlLpl 1-1 RidsNrrLAKGoldstein RidsRgn1 MailCenter RidsNrrDssSrxb ADAMS Accession No.: ML15051A032 Sincerely, IRA/
Nadiyah S. Morgan, Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation RidsNrrPMPilgrim RidsAcrsAcnw _MailCTR S. Krepel F. Forsaty OFFICE LPLl-1/PM LPLl-1/LA SRXB/BC LPLl-1/BC NAME NMorgan KGoldstein CJackson BBeaslev DATE 2/24/2015 02/24/2015 2/24/2015 2/25/2015 OFFICIAL RECORDS COPY