MONTHYEARML12003A0632011-12-16016 December 2011 Tornado and High Energy Line Break (HELB) Mitigation License Amendment Requests (Lars) - Responses to Request for Additional Information, Part 2 of 6 Project stage: Response to RAI ML12025A1242012-01-20020 January 2012 Tornado and High Energy Line Break Mitigation License Amendment Requests (Lars) - Supplemental Responses to Request for Additional Information (RAI) Nos. 61, 62, and 107 Project stage: Supplement ML12047A1772012-02-16016 February 2012 Request for Additional Information Regarding the License Amendment Requests for Upgrading the Licensing Basis for High Energy Line Break Mitigation Project stage: RAI ML12080A1992012-03-0101 March 2012 Tornado and High Energy Line Break Mitigation License Amendment Requests - Supplemental Responses to Request for Additional Information Nos. 70, 76, and 106 Project stage: Supplement ML12109A3452012-03-16016 March 2012 Supplement to License Amendment Request for Measurement Uncertainty Recapture Power Uprate, License Amendment Request No. 2011-02, Supplement 2 Project stage: Supplement ML12144A4442012-06-11011 June 2012 Request for Additional Information Regarding the License Amendment Request for Licensing Basis for the Protected Service Water System (TAC ME7737, ME7738, ME7739, ME7746, ME7747, & ME7748) Project stage: RAI ML12188A0712012-07-11011 July 2012 G20120473/ EDATS: OEDO-2012-0404 - Briefing Book - Briefing Package for Meeting with Duke Energy on July 11, 2012 Project stage: Request ML12312A0312012-11-0202 November 2012 Licensing Basis for the Protected Service Water System - Responses to Request for Additional Information - Supplement 3 Project stage: Supplement ML12354A2722012-12-20020 December 2012 Request for Additional Information and Suspension of Review of License Amendment Request for Revised Licensing Basis for High-Energy Line Breaks Project stage: RAI ML13123A1592013-04-0505 April 2013 Response to Request for Additional Information to Licensing Basis for the Protected Service Water System - Supplement 4 Project stage: Supplement ML13190A0162013-06-28028 June 2013 Licensing Basis for the Protected Service Water System - Responses to Request for Additional Information - Supplement 5 Project stage: Supplement ML13228A2682013-08-0707 August 2013 Licensing Basis for Protected Service Water System - Updated Responses to Request for Additional Information Item Nos. 107, 109(a) and 109(b); License Amendment Request (LAR) 2008-07-Supplement 6 Project stage: Supplement ML13262A3432013-09-19019 September 2013 10/3/2013 Meeting Notice with Duke Energy Carolinas, LLC, to Discuss the Proposed LAR Protected Service Water System Operation for the Oconee Nuclear Station, Units 1, 2, and 3 (TAC Nos. ME7737, ME7738, ME7739, ME7746, ME7747, and ME7748 Project stage: Meeting ML13281A6972013-10-21021 October 2013 10/3/13 Summary of Meeting with Duke Energy Carolinas, LLC to Discuss the Protected Service Water System Operation - Oconee Nuclear Station Units 1, 2, and 3 Project stage: Meeting ONS-2013-037, Licensing Basis for Protected Service Water System - Responses to Request for Additional Information Item Nos. 172 Through 189, License Amendment Request (LAR) 2008-07 - Supplement 72013-12-18018 December 2013 Licensing Basis for Protected Service Water System - Responses to Request for Additional Information Item Nos. 172 Through 189, License Amendment Request (LAR) 2008-07 - Supplement 7 Project stage: Supplement ML14043A2772014-01-28028 January 2014 1/28/14 E-mail from R.Guzman to T.Brown Request for Additional Information - Protected Service Water Modification Calculation OSC-9211 Project stage: RAI ONS-2014-021, Licensing Basis for the Protected Service Water System - Response to Request for Additional Information (RAI) No. 190; Revised Responses to RAI Nos. 134 and 165; License Amendment Request (LAR) 2008-07 - Supplement 82014-02-14014 February 2014 Licensing Basis for the Protected Service Water System - Response to Request for Additional Information (RAI) No. 190; Revised Responses to RAI Nos. 134 and 165; License Amendment Request (LAR) 2008-07 - Supplement 8 Project stage: Supplement ONS-2014-048, Licensing Basis for the Protected Service Water (Psw) System - Response to Request for Additional Information (RAI) Nos. 191-194; License Amendment Request (LAR) 2008-07 - Supplement 92014-04-0303 April 2014 Licensing Basis for the Protected Service Water (Psw) System - Response to Request for Additional Information (RAI) Nos. 191-194; License Amendment Request (LAR) 2008-07 - Supplement 9 Project stage: Supplement ML14099A5172014-04-0909 April 2014 Duke Energy Supplemental Response Protected Service Water LAR - GOTHIC Modeling Questions - 4/9/14 E-mail from R.Gambrell (Duke Energy) to R.Guzman (NRC) Project stage: Supplement ONS-2014-056, License Condition for the Unit 3 High Energy Line Break (Helb); License Amendment Request (LAR) 2008-07; Supplement 102014-04-11011 April 2014 License Condition for the Unit 3 High Energy Line Break (Helb); License Amendment Request (LAR) 2008-07; Supplement 10 Project stage: Supplement ML14157A2402014-04-29029 April 2014 NRR E-mail Capture - Psw Commitments Project stage: Request 05000269/LER-2014-001, Regarding Unanalyzed Condition Associated with the 13.8kV Emergency Power Cables Located in the Underground Trench2014-05-27027 May 2014 Regarding Unanalyzed Condition Associated with the 13.8kV Emergency Power Cables Located in the Underground Trench Project stage: Request ONS-2014-061, Licensing Basis for the Protected Service Water (Psw) System - Response to Requests for Additional Information Regarding Psw Cabling Aging Management Program and Fant Line Supply to Psw Degraded Voltage Protection; License Amendment Req2014-07-24024 July 2014 Licensing Basis for the Protected Service Water (Psw) System - Response to Requests for Additional Information Regarding Psw Cabling Aging Management Program and Fant Line Supply to Psw Degraded Voltage Protection; License Amendment Request Project stage: Response to RAI ML14206A7902014-08-13013 August 2014 Issuance of Amendments Regarding Implementation of the Protected Service Water System Project stage: Approval 2013-04-05
[Table View] |
Text
...~" REGui UNITED STATES
~.§,'>,;
<<7"'01\\
NUCLEAR REGULATORY COMMISSION
~
WASHINGTON, D.C. 20555-0001 0
Iii
~
~
October 21, 2013 V';.
~
1-1}
,..0 LICENSEE:
Duke Energy Carolinas, LLC FACILITY:
Oconee Nuclear Station, Units 1,2, and 3
SUBJECT:
SUMMARY
OF OCTOBER 3, MEETING WITH DUKE ENERGY CAROLINAS, LLC, TO DISCUSS THE PROPOSED LICENSE AMENDMENT REQUEST REGARDING THE PROTECTED SERVICE WATER SYSTEM OPERATION FOR THE OCONEE NUCLEAR STATION, UNITS 1,2, AND 3 (TAC NOS.
ME7737, ME7738, ME7739, ME7746, ME7747, AND ME7748)
On October 3, 2013, a Category 1 public meeting was held among staff from the U.S. Nuclear Regulatory Commission (NRC) and representatives of Duke Energy Carolinas, LLC (Duke or the licensee) at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. A list of attendees is enclosed. The purpose of the meeting was to allow the licensee to discuss their analyses performed and proposed alternate means of providing cooling to the reactor building and auxiliary building associated with the operation of the Protected Water System (PSW) in support of its response to the NRC staff's request for additional information (RAI-170) dated June 28,2013, Agencywide Documents Access and Management System (ADAMS) Accession No. ML13190A016. RAI-170 concerns the effects of the increased heat loads associated with the operation of the PSW system and the licensees proposed response to address the resulting temperature increases.
There were no members of the public in attendance, and no public meeting feedback forms were received. A list of attendees is enclosed. The licensee's meeting slides is available in ADAMS at Accession No. ML13275A269.
Please direct any inquiries to me at 301-415-1030, or by email to Richard.Guzman@nrc.gov.
Richard V. Guzman, Senior Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287
Enclosure:
List of Attendees cc w/encls: Distribution via Listserv
LIST OF ATTENDEES OCTOBER 3,2013, 10:00 AM TO 11 :30 AM MEETING WITH DUKE ENERGY CAROLINAS, LLC PROTECTED SERVICE WATER SYSTEM OPERATION ALTERNATE COOLING OCONEE NUCLEAR STATION, UNITS 1,2, AND 3 DOCKET NOS, 50-269, 50-270, AND 50-287 NAME ORGANIZATION John Monninger U.S. Nuclear Regulatory Commission (NRC)
Jake Zimmerman NRC Robert Pascarelli NRC Richard Guzman
!\\IRC Alexander TSirigotis NRC Swagata Som NRC Matthew Hamm NRC Evan Davidson NRC Edward Smith NRC Kamishan Martin NRC Dave Baxter Duke Energy Carolinas, LLC (Duke)
Rich Freudenberger Duke Jason Patterson Duke Timothy Brown Duke B.J. Gatten*
Duke
- Participated via conference line Enclosure
October 21,2013 LICENSEE:
Duke Energy Carolinas, LLC FACILITY:
Oconee Nuclear Station, Units 1, 2, and 3
SUBJECT:
SUMMARY
OF OCTOBER 3, MEETING WITH DUKE ENERGY CAROLINAS, LLC, TO DISCUSS THE PROPOSED LICENSE AMENDMENT REQUEST REGARDING THE PROTECTED SERVICE WATER SYSTEM OPERATION FOR THE OCONEE NUCLEAR STATION, UNITS 1,2, AND 3 (TAC NOS.
ME7737, ME7738, ME7739, ME7746, ME7747, AND ME7748)
On October 3,2013, a Category 1 public meeting was held among staff from the U.S. Nuclear Regulatory Commission (NRC) and representatives of Duke Energy Carolinas, LLC (Duke or the licensee) at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. A list of attendees is enclosed. The purpose of the meeting was to allow the licensee to discuss their analyses performed and proposed alternate means of providing cooling to the reactor building and auxiliary building associated with the operation of the Protected Water System (PSW) in support of its response to the NRC staff's request for additional information (RAI-170) dated June 28,2013, Agencywide Documents Access and Management System (ADAMS) Accession No. ML13190A016. RAI-170 concerns the effects of the increased heat loads associated with the operation of the PSW system and the licensees proposed response to address the resulting temperature increases.
There were no members of the public in attendance, and no public meeting feedback forms were received. A list of attendees is enclosed. The licensee's meeting slides is available in ADAMS at Accession No. ML13275A269.
Please direct any inquiries to me at 301-415-1030, or by email to Richard.Guzman@nrc.gov.
IRA!
Richard V. Guzman, Senior Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287
Enclosure:
List of Attendees cc w/encls: Distribution via Listserv DISTRIBUTION:
PUBLIC RPascarelli, NRR JMonninger, NRR ESmith NRR LPL2-1 r/f RidsNrrDorl ATsirigotis, NRR JZimmerman, NRR RidsNrrDorlLpl2-1 Resource SSom, NRR MHamm, NRR KMartin, NRR EDavidson, NRR RidsNrrLASFigueroa RidsNrrPMOconee RidsRgn2MailCenter ADAMS Accession Nos.: PKG: ML13281A565 Notice: ML13262A343 srd ML13275A269 Summary: ML13281A697 I es:
OFFICE DORULPL2-1/PM DORULPL2-1/LA DORULPL2-1/BC DORULPL2-1/PM NAME RGuzman SFigueroa RPascarelli RGuzman
- DATE 10/9/13 10/9/13 10/18/13 10/21/13 OFFICIAL RECORD COpy