Quad Cities Station Exercise Report - 2008-08-27 Final Report - Radiological Emergency Preparedness (REP) Program 2008-11-14
Exercise Report Quad Cities Station Exercise Date: 2008-08-27 Report Date: 2008-11-14 U.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency REP Program 536 S. Clark St. 6th floor Chicago, IL 60605
Table of Contents Chapter 1 Executive Summary Chapter 2 Introduction Chapter 3 Exercise Overview Section 3.1 EPZ Description Section 3.2 Exercise Participants Section 3.3 Exercise Timeline Chapter 4 Exercise Evaluation and Results Section 4.1 Summary Results of Exercise Evaluation Section 4.2 Status of Jurisdictions Evaluated 4.2.1 Illinois Jurisdictions 4.2.1.1 State of Illinois - Initial Warning Point 4.2.1.2 State of Illinois - State of Illinois Response Center 4.2.1.3 State of Illinois - Radiological Emergency Assessment Center 4.2.1.4 State of Illinois - Unified Area Command 4.2.1.5 State of Illinois - Emergency Operations Facility 4.2.1.6 State of Illinois - Joint Information Center 4.2.1.7 State of Illinois - Rock Island County Emergency Operations Center -
Illinois State Radiological Advisor 4.2.1.8 State of Illinois - Rock Island County Emergency Operations Center -
Illinois State Liaison 4.2.1.9 State of Illinois - Whiteside County Emergency Operations Center -
Illinois State Radiological Advisor 4.2.1.10 State of Illinois - Whiteside County Emergency Operations Center -
Illinois State Liaison 4.2.1.11 State of Illinois - Illinois State Police District 7 Headquarters -
Dosimetry Control Officer Briefing 4.2.1.12 State of Illinois - Illinois State Police District 7 Headquarters - Traffic and Access Control Post 4.2.1.13 State of Illinois - Trinity Medical Center - Medical Service -
Transportation 4.2.1.14 State of Illinois - Trinity Medical Center - Medical Service - Facility 4.2.2 Risk Jurisdictions 4.2.2.1 Rock Island County - Initial Warning Point 4.2.2.2 Rock Island County - Emergency Operations Center
4.2.2.3 Rock Island County - Sheriffs Department - Traffic and Access Control Post 4.2.2.4 Rock Island County - Emergency Broadcast System Station - WVIK 4.2.2.5 Whiteside County - Initial Warning Point 4.2.2.6 Whiteside County - Emergency Operations Center 4.2.2.7 Whiteside County - Sheriff Department - Traffic and Access Control Post 4.2.2.8 Whiteside County - Emergency Broadcast Station -
WSDR/WZZT/WSSQ Appendices Appendix 1 - Acronyms and Abbreviations Appendix 2 - Exercise Evaluators and Team Leaders Appendix 3 - Exercise Evaluation Areas and Extent of Play Agreement Appendix 4 - Exercise Scenario and Timeline
- 1. Executive Summary On August 27, 2008, a Radiological Emergency Preparedness (REP) Partial Participation Plume Exposure Pathway Exercise was conducted for the 10-mile Emergency Planning Zone (EPZ) around the Quad Cities Nuclear Power Station by the U.S. Department of Homeland Security/Federal Emergency Management Agency (DHS/FEMA). The purpose of the exercise was to assess the level of State and local preparedness in responding to a radiological emergency. This exercise was held in accordance with DHS/FEMA's policies and guidance concerning the exercise of State and local Radiological Emergency Response Plans (RERPs) and procedures.
The most recent exercise at this site was conducted on May 17, 2006. The qualifying emergency preparedness exercise was conducted on May 20, 1981.
DHS/FEMA wishes to acknowledge the efforts of the many individuals who participated in this exercise. In the State of Illinois Emergency Management Agency, the Counties of Quad Cities and Whiteside and Exelon Corporation who participated along with the State Government.
Protecting the public health and safety is the full-time job of some of the exercise participants and an additional assigned responsibility for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities. Cooperation and teamwork on the part of all the participants were evident during this exercise.
This Report contains the evaluation of the biennial exercise and the evaluation of the following out-of-sequence interviews and activities: Illinois State Police (ISP) Dosimetry Control Officers Briefing and ISP Traffic and Access Control Point at the ISP District 7 Headquarters, and Medical Services of the Trinity Medical Center Hospital and the Trinity Medical Center Transportation Service. The State and local organizations, except where noted in this report, demonstrated knowledge of their emergency response plans and procedures and adequately implemented them.
There were no Deficiencies identified during this exercise for the State of Illinois, or for the Counties of Rock Island or Whiteside.
There were no new Areas Requiring Corrective Actions identified during this exercise 1
for the State of Illinois and the Counties of Rock Island or Whiteside.
There was one Areas Requiring Corrective Action from a previous exercise, Issue number 51-06-6.d.1-A-01 that was not corrected during the exercises for the State of Illinois. While some of the concerns listed in the Issue were satisfactorily addressed such as radiological monitoring and contamination control techniques, others were not satisfactorily performed. The items include the doffing of radiological clothing, not bagging and label of appropriate samples, no swabs collected or personal contamination samples collected, and the bagging and passing equipment over the REA boundary, were not satisfactory performed or were not demonstrated.
A detailed discussion of these issues can be found in Part IV of this Report.
2
- 2. Introduction On December 7, 1979, the President directed FEMA to assume the lead responsibility for all offsite nuclear planning and response. DHS/FEMA's activities are conducted pursuant to 44 Code of Federal Regulations (CFR) Parts 350, 351 and 352. These regulations are a key element in the Radiological Emergency Preparedness (REP)
Program that was established following the Three Mile Island Nuclear Station accident in March 1979.
The FEMA Rule 44 CFR 350 establishes the policies and procedures for DHS/FEMA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local governments' participation in joint exercises with licensees.
DHS/FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities include the following:
Taking the lead in off-site emergency planning and in the review and evaluation of RERPs and procedures developed by State and local governments;
- Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises of the plans and procedures conducted by State and local governments;
- Responding to requests by the U.S. Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA dated June 17, 1993 (Federal Register, Vol. 58, No. 176, September 14, 1993); and
- Coordinating the activities of Federal agencies with responsibilities in the radiological emergency planning process:
- U.S. Department of Agriculture;
- U.S. Department of Commerce;
- U.S. Department of Energy;
- U.S. Department of Health and Human Services;
- U.S. Department of the Interior; 3
- U.S. Department of Transportation;
- U.S. Environmental Protection Agency;
- U.S. Food and Drug Administration; and
- U.S. Nuclear Regulatory Commission.
Representatives of these agencies serve on the DHS/FEMA Region V Regional Assistance Committee (RAC), which is chaired by DHS/FEMA.
Formal submission of the RERPs for the Quad Cities to FEMA Region V by the State of Illinois and involved local jurisdictions occurred on December 15, 1982. Formal approval of these RERPs was granted by FEMA on March 2, 1984, under 44 CFR 350.
A REP Partial Participation Plume Exposure Pathway Exercise was conducted on August 27, 2008, and evaluated by DHS/FEMA to assess the capabilities of State and local offsite emergency preparedness organizations in implementing their RERPs and procedures to protect the public health and safety during a radiological emergency involving the Quad Cities Nuclear Power Station. The purpose of this exercise report is to present the exercise results and findings on the performance of the offsite response organizations (ORO) during a simulated radiological emergency.
The findings presented in this report are based on the evaluations of the Federal evaluation team, with final determinations made by the DHS/FEMA Region V RAC Chairperson, and approved by the Regional Administrator.
The criteria utilized in the FEMA evaluation process are contained in:
- NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980;
- FEMA-REP-14, "Radiological Emergency Preparedness Exercise Manual," September 1991; and
- FEMA "Radiological Emergency Preparedness: Exercise Evaluation Methodology; Notice" as published in the Federal Register Notice, Vol. 67, No. 80, dated April 25, 2002.
Section III of this report, entitled "Exercise Overview", presents basic information and 4
data relevant to the exercise. This section of the report contains a description of the plume pathway EPZ, a listing of all participating jurisdictions and functional entities, which were evaluated, and a tabular presentation of the time of actual occurrence of key exercise events and activities.
Section IV of this report, entitled "Exercise Evaluation and Results," presents detailed information on the demonstration of applicable exercise criteria at each jurisdiction or functional entity evaluated in a jurisdiction-based, issues-only format. This section also contains: (1) descriptions of all Deficiencies and ARCAs assessed during this exercise, recommended corrective actions, and the State and local governments' schedule of corrective actions, if applicable, for each identified exercise issue; and (2) descriptions of unresolved ARCAs assessed during previous exercises and the status of the OROs' efforts to resolve them.
5
- 3. Exercise Overview Contained in this section are data and basic information relevant to the August 27, 2008, REP Partial Participation Plume Exposure Pathway Exercise to test the offsite emergency response capabilities in the area surrounding the Quad Cities. This section of the exercise report includes a description of the 10-mile Emergency Planning Zone and a listing of all participating jurisdictions and functional entities which were evaluated, and a tabular presentation of the time of actual occurrence of key exercise events and activities.
3.1. EPZ Description The Quad Cities Nuclear Power Station is located in Rock Island County, Illinois. The Station is 20 miles northeast of the Quad Cities. It is on the eastern bank of the Mississippi River opposite the mouth of the Wapsipinicon River.
The topography of the site and its immediate environs is low and relatively flat, with a mean elevation of approximately 605 feet. The ground surface drops off abruptly at the bank of the river, forming a bluff about 30 feet high.
The 10-mile EPZ encompasses the following jurisdictions: Rock Island County, which includes the municipalities of Cordova and Port Byron, and Whiteside County, which includes the municipality of Albany.
The 2004 population of the 10-mile EPZ is 3,258 persons. The primary land use around the Quad Cities Nuclear Power Station is agricultural, with cash grain crops of corn and soybeans. The closest major industries are located in the Cordova Industrial Park northeast of the Station.
Major transportation facilities in the Quad Cities Nuclear Power Station 10-mile EPZ are limited to Interstate Highway 88, which passes nine and one-half (9 1/2) miles southeast of the Station; the I&M Raillink and the Mississippi River.
The EPZ also includes several Counties within the State of Iowa within the Jurisdiction of FEMA Region VII.
6
3.2. Exercise Participants Agencies and organizations of the following jurisdictions participated in the Quad Cities Station exercise:
State Jurisdictions Illinois Department of Natural Resources Police Illinois Department of Transportation Illinois Emergency Management Agency Illinois Environmental Protection Agency Illinois State Police Risk Jurisdictions Rock Island County Board Rock Island County Emergency Management Agency (EMA)
Rock Island County Sheriff's Department Rock Island County Health Department Rock Island County Highway Department Rock Island County Coroner Rock Island County Human Resources Rock Island County Regional Superintendent of Schools Riverside School District #100 City of Cordova City of Port Byron Whiteside County EMA Whiteside County Sheriff's Department Whiteside County Highway Department Whiteside County Health Department Whiteside County Coroner Whiteside County Public Information Officer Whiteside County Superintendent of Schools City of Albany Support Jurisdictions American Red Cross Whiteside County Amateur Radio Emergency Service Rock Island EMA Volunteers Private Jurisdictions Emergency Broadcast System Station - WSDR/WZZT/WSSQ 7
Emergency Broadcast System Station - WVIK Exelon Nuclear Trinity Medical Center Trinity Medical Center Ambulance Quad Cities Nuclear Power Station 3.3. Exercise Timeline Table 1, on the following page, presents the times at which key events and activities occurred during the REP Partial Participation Plume Exposure Pathway Exercise conducted on August 27, 2008, for the Quad Cities Nuclear Power Station.
8
Table 1 - Exercise Timeline DATE: 2008-08-27, SITE: Quad Cities Station, IL Emergency Classification Level or Event Time Utility Declared IL - SIRC IL - REAC IL - UAC IL - JIC ROC-EOC---
WHI-EOC---
Unusual Event NA NA NA NA NA NA NA Alert 0815 0815 0828 0850 0837 0843 0842 Site Area Emergency 0938 0950 0953 1005 0948 1001 1006 General Emergency 1116 1129 1131 1135 1136 1142 1150 Simulated Rad. Release Started 1111 1129 1111 1135 1136 1142 1150 Simulated Rad. Release Terminated NA NA NA NA NA NA NA Facility Declared Operational 0945 0857 0900 0935 0910 0930 Declaration of State of Emergency 1200 NA 1147 1202 1205 1154 Exercise Terminated 1235 1232 1240 1250 1305 1256 Early Precautionary Actions:
1005/1017 0944 NA 1032 NA NA 1st Protective Action Decision:
1020 NA NA NA 1020 1016 1st Siren Activation NA NA NA NA 1020 1020 1st EAS or EBS Message NA NA NA NA 1022 1023 2nd Protective Action Decision:
1139 NA 1135 1136 1145 1157 2nd Siren Activation NA NA NA NA 1200 1200 2nd EAS or EBS Message NA NA NA NA 1203 1203 3rd Protective Action Decision:
3rd Siren Activation 3rd EAS or EBS Message 4th Protective Action Decision:
4th Siren Activation 4th EAS or EBS Message 5th Protective Action Decision:
5th Siren Activation 5th EAS or EBS Message 6th Protective Action Decision:
6th Siren Activation 6th EAS or EBS Message KI Administration Decision:
1113 1113 1135 1136 1145 1157 9
- 4. Exercise Evaluation and Results Contained in this section are the results and findings of the evaluation of all jurisdictions and functional entities that participated in the August 27, 2008, REP Partial Participation Plume Exposure Pathway Exercise to test the off-site emergency response capabilities of State and local governments in the 10-mile EPZ surrounding the Quad Cities.
Each jurisdiction and functional entity was evaluated based on its demonstration of exercise criteria delineated in Federal Register Notice: Vol. 67, No. 80, dated April 25, 2002. Detailed information on the exercise criteria and the extent of play agreement used in this exercise are found in Appendix 3 of this report.
4.1. Summary Results of Exercise Evaluation The matrix presented in Table 2, on the following page(s), presents the status of all exercise criteria from Federal Register Notice: Vol. 67, No. 80, dated April 25, 2002, which were scheduled for demonstration during this exercise by all participating jurisdictions and functional entities. Exercise criteria are listed by number and the demonstration status of those criteria are indicated by the use of the following letters:
M - Met (No Deficiency or ARCA assessed and no unresolved ARCAs from prior exercises)
D - Deficiency assessed A - ARCA(s) assessed or unresolved ARCA(s) from prior exercise(s)
N - Not Demonstrated (Reason explained in Section IV.B.)
Blank - Not scheduled for demonstration 10
Table 2 - Summary of Exercise Evaluation (2 pages)
DATE: 2008-08-27 SITE: Quad Cities Station, IL A: ARCA, D: Deficiency, M: Met, N: Not Demonstrated IL - IWP IL - SIRC IL - REAC IL - UAC IL - EOF IL - JIC IL-EOC ROC--IL/SRA-IL-EOC ROC--IL/SL-IL-EOC WHI--IL/SRA-IL-EOC WHI--IL/SL-IL-ISP D#7 HQ--DCO B-Emergency Operations Management Mobilization 1a1 M M M M M M M
Facilities 1b1 Direction and Control 1c1 M M M M M M M M M Communications Equipment 1d1 M M M M M M M M M M Equipment and Supplies to Support Operations 1e1 M M M M M M
M Protective Action Decision Making EW Exposure Control Decisions 2a1 M M PARs 2b1 M M PADs 2b2 M M M M
M PADs for Disabled/Functional Needs 2c1 M M M
M Ingestion PADs 2d1 RRR Decisions 2e1 Protective Action Implementation EW Exposure Control Implementation 3a1 M
M M
KI Public/Institutionalized 3b1 M
PAD Implementation Disabled/Functional Needs 3c1 PAD Implementation Schools 3c2 TACP Establishment 3d1 M
Impediments 3d2 M
Implement Ingestion PADs 3e1 Coordination of RRR Decisions 3e2 Coordination of RRR Decisions 3f1 Field Measurement and Analysis RESERVED 4a1 Field Team Management 4a2 Field Team Operations 4a3 Field Team Sampling 4b1 Laboratory Operations 4c1 Emergency Notification and Public Info Initial Alert & Notification 5a1 M
M M RESERVED 5a2 Backup Alert & Notification 5a3 Exception Area Alerting 5a4 Subsequent Information & Instructions 5b1 M M M M M M
Support Operations/Facilities Reception Center Operations 6a1 EW Monitoring & Decontamination 6b1 Congregate Care 6c1 Contaminated Injured Transport & Care 6d1 11
Table 2 - Summary of Exercise Evaluation (Continued. page 2/2)
DATE: 2008-08-27 SITE: Quad Cities Station, IL A: ARCA, D: Deficiency, M: Met, N: Not Demonstrated IL-ISP D#7 HQ--TACP-IL--Trinity MC Trans-IL-Trinity MC--MS1F-ROC-IWP---
ROC-EOC---
ROC--Sheriffs-TACP-ROC-EBS-WVIK---
WHI-IWP---
WHI-EOC---
WHI--Sheriffs-TACP-WHI-EBS-Emergency Operations Management Mobilization 1a1 M M M M Facilities 1b1 Direction and Control 1c1 M
M Communications Equipment 1d1 M M M M M M M M M M M Equipment and Supplies to Support Operations 1e1 M
M M M M M Protective Action Decision Making EW Exposure Control Decisions 2a1 PARs 2b1 PADs 2b2 M
M PADs for Disabled/Functional Needs 2c1 M
M Ingestion PADs 2d1 RRR Decisions 2e1 Protective Action Implementation EW Exposure Control Implementation 3a1 M
M M M M M KI Public/Institutionalized 3b1 M
M M M M PAD Implementation Disabled/Functional Needs 3c1 M
M PAD Implementation Schools 3c2 M
TACP Establishment 3d1 M
M M M M Impediments 3d2 M
M Implement Ingestion PADs 3e1 Coordination of RRR Decisions 3e2 Coordination of RRR Decisions 3f1 Field Measurement and Analysis RESERVED 4a1 Field Team Management 4a2 Field Team Operations 4a3 Field Team Sampling 4b1 Laboratory Operations 4c1 Emergency Notification and Public Info Initial Alert & Notification 5a1 M
M M
M RESERVED 5a2 Backup Alert & Notification 5a3 Exception Area Alerting 5a4 Subsequent Information & Instructions 5b1 M
M M
M Support Operations/Facilities Reception Center Operations 6a1 EW Monitoring & Decontamination 6b1 Congregate Care 6c1 Contaminated Injured Transport & Care 6d1 M A 12
4.2. Status of Jurisdictions Evaluated This subsection provides information on the evaluation of each participating jurisdiction and functional entity in a jurisdiction-based, issues-only format. Presented below are definitions of the terms used in this subsection relative to criteria demonstration status.
- Met - Listing of the demonstrated exercise criteria under which no Deficiencies or ARCAs were assessed during this exercise and under which no ARCAs assessed during prior exercises remain unresolved.
- Deficiency - Listing of the demonstrated exercise criteria under which one or more Deficiencies was assessed during this exercise. Included is a description of each Deficiency and recommended corrective actions.
- Area Requiring Corrective Action - Listing of the demonstrated exercise criteria under which one or more ARCAs were assessed during the current exercise or ARCAs assessed during prior exercises remain unresolved. Included is a description of the ARCAs assessed during this exercise and the recommended corrective action to be demonstrated before or during the next biennial exercise.
- Not Demonstrated - Listing of the exercise criteria that were not demonstrated as scheduled during this exercise and the reason(s) they were not demonstrated.
- Prior ARCAs - Resolved - Descriptions of ARCAs assessed during previous exercises that were resolved in this exercise and the corrective actions demonstrated.
- Prior ARCAs - Unresolved - Descriptions of ARCAs assessed during prior exercises that were not resolved in this exercise. Included is the reason the ARCA remains unresolved and recommended corrective actions to be demonstrated before or during the next biennial exercise.
The following are definitions of the two types of exercise issues that maybe discussed in this report.
- A Deficiency is defined in FEMA-REP-14 as "...an observed or identified inadequacy of organizational performance in an exercise that could cause a finding that offsite emergency preparedness is not adequate to provide reasonable assurance that 13
appropriate protective measures can be taken in the event of a radiological emergency to protect the health and safety of the public living in the vicinity of a nuclear power plant."
- An ARCA is defined in FEMA-REP-14 as "...an observed or identified inadequacy of organizational performance in an exercise that is not considered, by itself, to adversely impact public health and safety."
The DHS/FEMA has developed a standardized system for numbering exercise issues (Deficiencies and ARCAs). This system is used to achieve consistency in numbering exercise issues among DHS/FEMA Regions and site-specific exercise reports within each Region. It also is used to expedite tracking of exercise issues on a nationwide basis.
The identifying number of Deficiencies and ARCAs includes the following elements, with each element separated by a hyphen (-).
- Plant Site Identifier - A two-digit number, corresponding to the Utility Billable Plant Site Code.
- Exercise Year - The last two digits of the year the exercise was conducted.
- Criterion Number - An alpha and two-digit number corresponding to the criteria numbers in the six Exercise Evaluation Areas described in Federal Register Notice, Vol.
67, No. 80, dated April 25, 2002, which amends FEMA-REP 14, Radiological Emergency Preparedness Exercise Manual.
- Issue Classification Identifier - (D = Deficiency, A = ARCA). Only Deficiencies and ARCAs are included in exercise reports. Planning Issues are reported to the State(s) via a letter from the Regional Director. Therefore, standardized issue numbers are not assigned to Planning Issues.
- Exercise Identification Number - A separate two- (or three-) digit indexing number assigned to each issue identified in the exercise.
4.2.1. Illinois Jurisdictions 14
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
4.2.1.1. State of Illinois - Initial Warning Point MET: 1.a.1, 1.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.2. State of Illinois - State of Illinois Response Center MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.a.1, 2.b.1, 2.b.2, 2.c.1, 5.a.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.3. State of Illinois - Radiological Emergency Assessment Center MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.a.1, 2.b.1, 2.b.2, 2.c.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.4. State of Illinois - Unified Area Command MET: 1.c.1, 1.d.1, 1.e.1, 2.b.2, 3.d.1, 3.d.2, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None 15
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.5. State of Illinois - Emergency Operations Facility MET: 1.a.1, 1.c.1, 1.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.6. State of Illinois - Joint Information Center MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.7. State of Illinois - Rock Island County Emergency Operations Center - Illinois State Radiological Advisor MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.b.2, 2.c.1, 3.a.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 16
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
4.2.1.8. State of Illinois - Rock Island County Emergency Operations Center - Illinois State Liaison MET: 1.c.1, 1.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.9. State of Illinois - Whiteside County Emergency Operations Center - Illinois State Radiological Advisor MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.b.2, 2.c.1, 3.a.1, 5.a.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.10. State of Illinois - Whiteside County Emergency Operations Center - Illinois State Liaison MET: 1.c.1, 1.d.1, 5.a.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.11. State of Illinois - Illinois State Police District 7 Headquarters - Dosimetry Control Officer Briefing 17
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
MET: 1.e.1, 3.a.1, 3.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.12. State of Illinois - Illinois State Police District 7 Headquarters - Traffic and Access Control Post MET: 1.d.1, 1.e.1, 3.a.1, 3.b.1, 3.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.13. State of Illinois - Trinity Medical Center -
Medical Service - Transportation MET: 1.d.1, 6.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.1.14. State of Illinois - Trinity Medical Center -
Medical Service - Facility MET: 1.d.1, 1.e.1, 3.a.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None 18
e.
f.
a.
b.
c.
d.
e.
f.
PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: 6.d.1.
ISSUE NO.: 51-06-6d1-A-01 ISSUE: Monitoring techniques and contamination control were not adequate.
REASON UNRESOLVED: This out-of-sequence drill was intended to address and demonstrate resolution of items contained in Issue Number: 51 6.d.A.01. While some of the concerns listed in the Issue were satisfactorily addressed such as radiological monitoring and contamination control techniques, others were not satisfactorily performed (doffing of radiological clothing, not bagging and label of appropriate samples) were not demonstrated or (bagging and passing equipment over the REA boundary).
SCHEDULE OF CORRECTIVE ACTIONS The State of Illinois will review the procedures and training that addresses monitoring techniques and contamination control. In addition, supplemental training and mock drills will be held to ensure all monitoring and contamination control issues are addressed properly before the next drill.
4.2.2. Risk Jurisdictions 4.2.2.1. Rock Island County - Initial Warning Point MET: 1.a.1, 1.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.2.2. Rock Island County - Emergency Operations Center 19
a.
b.
c.
d.
e.
f.
a.
b.
c.
MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.b.2, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.c.2, 3.d.1, 3.d.2, 5.a.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: 3.d.1.
ISSUE NO.: 51-06-3d1-A-02 ISSUE: Sub-areas 1 and 3 were the evacuated in Rock Island County.
County Sheriff's Representatives identified TACPs and simulated sending personnel to points that were on the line dividing sub-area 1 from sub-area 3 (inside the evacuated areas) and not on the line dividing sub-area 3 from sub-area 6 (between the evacuated and non-evacuated sub-areas).
CORRECTIVE ACTION DEMONSTRATED: In the previous exercise there was an ARCA due to not fully positioning TACPs on the line between evacuated and non-evacuated sub-areas, possibly allowing traffic to enter an evacuated area (sub-area 3). To address this, a Controller inject was initiated at 1235 hours0.0143 days <br />0.343 hours <br />0.00204 weeks <br />4.699175e-4 months <br /> and given to the ISP and County Sheriff Department representatives simulating a second PAR for evacuation of sub-areas 5 and 6 in Rock Island County. A new TACP plan was developed which pulled personnel from TACP locations in sub-areas 1 and 3 and re-deployed them to pre-identified TACPs along the outer edge of sub-areas 5 and 6. This would be fully coordinated with Whiteside County so that their TACPs would also be fully staffed. This demonstration and interview corrected the previous ARCA.
PRIOR ISSUES - UNRESOLVED: None 4.2.2.3. Rock Island County - Sheriffs Department -
Traffic and Access Control Post MET: 1.d.1, 1.e.1, 3.a.1, 3.b.1, 3.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None 20
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.2.4. Rock Island County - Emergency Broadcast System Station - WVIK MET: 1.d.1, 5.a.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.2.5. Whiteside County - Initial Warning Point MET: 1.a.1, 1.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.2.6. Whiteside County - Emergency Operations Center MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.b.2, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.d.1, 3.d.2, 5.a.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: 5.a.1.
ISSUE NO.: 51-06-5a1-A-03 ISSUE: The ESDA Director immediately began his EBS message without 21
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
providing the required "Password". According to Radio Station procedures that were provided by the Whiteside County ESDA, the ESDA Director is directed to first verify the message by announcing the prearranged "Password" (exercise or real world) and then wait on the line until such time that the message content is verified by Radio Station Staff.
CORRECTIVE ACTION DEMONSTRATED: Whiteside County officials followed procedures by properly identifying the source and providing the correct authentication password to the EBS radio station staff. The radio station verified the authentication password prior to recording and simulating the broadcast of the EBS messages.
PRIOR ISSUES - UNRESOLVED: None 4.2.2.7. Whiteside County - Sheriff Department -
Traffic and Access Control Post MET: 1.d.1, 1.e.1, 3.a.1, 3.b.1, 3.d.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 4.2.2.8. Whiteside County - Emergency Broadcast Station - WSDR/WZZT/WSSQ MET: 1.d.1, 5.a.1, 5.b.1.
AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 22
APPENDIX 1 ACRONYMS AND ABBREVIATIONS ACP Access Control Point ALARA As Low As Reasonable Achievable ALS Advanced Life Support ARC American Red Cross ARCA Area Requiring Corrective Action ARES Amateur Radio Emergency Services ATG Office of the Illinois Attorney General BLS Basic Life Support CAP Civil Air Patrol CCC Congregate Care Center CD-V Civil Defense-Category V CFR Code of Federal Regulations cpm counts per minute DCO Dosimetry Control Officer DHS Department of Homeland Security DRD Direct-Reading Dosimeter EAL Emergency Action Level EBS Emergency Broadcast System ECL Emergency Classification Level ED Emergency Department EM Emergency Management EMA Emergency Management Agency EMS Emergency Medical Services EOC Emergency Operations Center EOF Emergency Operations Facility EPZ Emergency Planning Zone EV-2 Protective Actions for School Children EW Emergency Worker FEMA Federal Emergency Management Agency FTC Field Team Center GE General Emergency GIS Geographical Information System HP Health Physics or Health Physicist HS High School ICC Illinois Commerce Commission ICF ICF Consulting ICP Illinois Conservation Police IDA Illinois Department of Agriculture IDHS Illinois Department of Human Services IDMA Illinois Department of Military Affairs IDNR Illinois Department of Natural Resources IDOT-A Illinois Department of Transportation-Division of Aeronautics IDOT-H Illinois Department of Transportation-Division of Highways 23
IDPH Illinois Department of Public Health IEMA Illinois Emergency Management Agency IEPA Illinois Environmental Protection Agency IPRA Illinois Plan for Radiological Accidents IREACH Illinois Radio Emergency Aid Channel ISP Illinois State Police IWP Initial Warning Point JIC Joint Information Center KI Potassium Iodide LEADS Law Enforcement Agency Data System LEIRS Local Emergency Information Radio Station M&D Monitoring and Decontamination MDT Mobile Data Terminal mR milliRoentgen mR/hr milliRoentgen per Hour MS-1 Medical Services Drill NARS Nuclear Accident Reporting System NRC Nuclear Regulatory Commission NTRC Northern Technical Response Center NUREG-0654 NUREG-0654/FEMA-REP-1, Rev. 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, November 1980.
NWS National Weather Service ORO Off-site Response Organization OSLD Optically Stimulated Luminescent Dosimeter PAD Protective Action Decision PAG Protective Action Guide PAO Public Affairs Official PAR Protective Action Recommendation PIO Public Information Officer PNS Prompt Notification System QCNPS Quad Cities Nuclear Power Station R
Roentgen R/hr Roentgen per hour RAC Regional Assistance Committee RACES Radio Amateur Civil Emergency Services RAFT Radiological Assessment Field Team RASCAL Radiological Assessment System for Consequence Analysis RCP Reactor Coolant Pump RCS Reactor Coolant System RDO Radiological Defense Officer REA Radiological Emergency Area REAC Radiological Emergency Assessment Center rem Roentgen Equivalent Man REP Radiological Emergency Preparedness RERP Radiological Emergency Response Plan RMS Remote Monitoring System RO Radiological Officer RTF Radiological Task Force SAE Site Area Emergency 24
SEOC State Emergency Operations Center SGTS Standby Gas Treatment System SIRC State Incident Response Center SOP Standard Operating Procedure T/L Team Leader TACP Traffic and Access Control Point TLD Thermoluminescent Dosimeter TLV Threshold Limit Value TSC Technical Support Center UAC Unified Area Command UHF Ultra High Frequency VHF Very High Frequency WCEOC Whiteside County Emergency Operations Center 25
APPENDIX 2 EXERCISE EVALUATORS AND TEAM LEADERS DATE: 2008-08-27, SITE: Quad Cities Station, IL LOCATION EVALUATOR AGENCY State of Illinois - Initial Warning Point Kara Scott FEMA RV State of Illinois - State of Illinois Response Center Michael Meshenberg Kara Scott ICFI FEMA RV State of Illinois - Radiological Emergency Assessment Center Richard Grundstrom Bernis Hannah FEMA RIX ICFI State of Illinois - Unified Area Command Eugene Deener James Groves DHS/FEMA ICF State of Illinois - Emergency Operations Facility Robert Black ICFI State of Illinois - Joint Information Center Sandra Bailey DHS/FEMA State of Illinois - Rock Island County Emergency Operations Center - Illinois State Radiological Advisor Marynette Herndon Delwyn Kinsley Bruce Swiren ICFI FEMA RV ICFI State of Illinois - Rock Island County Emergency Operations Center - Illinois State Liaison Marynette Herndon Bruce Swiren ICFI ICFI State of Illinois - Whiteside County Emergency Operations Center - Illinois State Radiological Advisor Carl Bebrich Richard Smith FEMA RV ICF State of Illinois - Whiteside County Emergency Operations Center - Illinois State Liaison Carl Bebrich Richard Smith FEMA RV ICF State of Illinois - Illinois State Police District 7 Headquarters -
Dosimetry Control Officer Briefing Richard Wessman ICF State of Illinois - Illinois State Police District 7 Headquarters -
Traffic and Access Control Post Gary Bolender ICFI State of Illinois - Trinity Medical Center - Medical Service -
Transportation Todd Sniffin ICF State of Illinois - Trinity Medical Center - Medical Service -
Facility Robert Black ICFI Rock Island County - Initial Warning Point Gregg Dawkins ICF Rock Island County - Emergency Operations Center Marynette Herndon Delwyn Kinsley Bruce Swiren ICFI FEMA RV ICFI Rock Island County - Sheriffs Department - Traffic and Access Control Post Gregg Dawkins ICF Rock Island County - Emergency Broadcast System Station -
WVIK Richard Wessman ICF Whiteside County - Initial Warning Point Gary Bolender ICFI Whiteside County - Emergency Operations Center Carl Bebrich Richard Smith FEMA RV ICF Whiteside County - Sheriff Department - Traffic and Access Control Post Todd Sniffin ICF Whiteside County - Emergency Broadcast Station -
WSDR/WZZT/WSSQ Gary Bolender ICFI
- Team Leader 26
APPENDIX 3 EXERCISE CRITERIA AND EXTENT - OF - PLAY AGREEMENT This appendix lists the exercise criteria, which were scheduled for demonstration in the Quad Cities REP Partial Participation Plume Exposure Pathway Exercise on August 27, 2008, and the off-site extent-of-play agreement approved by DHS/FEMA Region V on July 30, 2008.
The exercise criteria, contained in the FEMA "Radiological Emergency Preparedness Exercise Evaluation Methodology; Notice, as published in the Federal Register Notice/Vol 67, dated April 25, 2002, represent a functional translation of the planning standards and evaluation criteria of NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for the Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980.
Because the exercise criteria are intended for use at all nuclear power plant sites, and because of variations among offsite plans and procedures, an extent-of-play agreement is prepared by the State and approved by DHS/FEMA to provide evaluators with guidance on expected actual demonstration of the criteria.
A.
Exercise Criteria Listed below are the specific radiological emergency preparedness criteria scheduled for demonstration during this exercise.
EVALUATION AREA 1 - EMERGENCY OPERATIONS MANAGEMENT SUB-ELEMENT 1.a - Mobilization Criterion 1.a.1 - OROs use effective procedures to alert, notify, and mobilize emergency personnel and activate facilities in a timely manner.
SUB-ELEMENT 1.c - Direction and Control Criterion 1.c.1 - Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.
SUB-ELEMENT 1.d - Communications Equipment Criterion 1.d.1 - At least two communications systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations.
May 28, 2008 27
SUB-ELEMENT 1.e - Equipment and Supplies to Support Operations Criterion 1.e.1 - Equipment, maps, displays, dosimetry, potassium iodide (KI), and other supplies are sufficient to support emergency operations.
EVALUATION AREA 2 - PROTECTIVE ACTION DECISION-MAKING SUB-ELEMENT 2.a - Emergency Worker Exposure Control Criterion 2.a.1 - OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.
SUB-ELEMENT 2.b - Radiological Assessment and Protective Action Recommendations and Decisions for the Plume Phase of the Emergency Criterion 2.b.1 - Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data, and licensee and ORO dose projections, as well as knowledge of onsite and offsite environmental conditions.
SUB-ELEMENT 2.b - Radiological Assessment and Protective Action Recommendations and Decisions for the Plume Phase of the Emergency Criterion 2.b.2 - A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PAD) for the general public (including the recommendation for the use of KI, if ORO policy).
SUB-ELEMENT 2.c - Protective Action Decisions for the Protection of Special Populations Criterion 2.c.1 - Protective action decisions are made, as appropriate, for special population groups.
EVALUATION AREA 3 - PROTECTIVE ACTION IMPLEMENTATION SUB-ELEMENT 3.a - Implementation of Emergency Worker Exposure Control Criterion 3.a.1 - The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plans and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.
SUB-ELEMENT 3.b - Implementation of KI Decision Criterion 3.b.1 - KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for May 28, 2008 28
emergency workers and institutionalized individuals (not the general public) is maintained.
SUB-ELEMENT 3.c. - Implementation of Protective Actions for Special Populations Criterion 3.c.1 - Protective action decisions are implemented for special populations other than schools within areas subject to protective actions.
SUB-ELEMENT 3.c. - Implementation of Protective Actions for Special Populations Criterion 3.c.2 - OROs/School officials decide upon and implement protective actions for schools.
SUB-ELEMENT 3.d. - Implementation of Traffic and Access Control Criterion 3.d.1. - Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.
SUB-ELEMENT 3.d. - Implementation of Traffic and Access Control Criterion 3.d.2 - Impediments to evacuation are identified and resolved.
EVALUATION AREA 5 - EMERGENCY NOTIFICATION AND PUBLIC INFORMATION SUB-ELEMENT 5.a - Activation of the Prompt Alert and Notification System Criterion 5.a.1 - Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP Guidance.
SUB-ELEMENT 5.b. - Emergency Information and Instructions for the Public and the Media Criterion 5.b.1. - OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.
EVALUATION AREA 6: SUPPORT OPERATION/FACILITIES SUB-ELEMENT 6.d - Transportation and Treatment of Contaminated Injured Individuals Criterion 6.d.1 - The facility/ORO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals.
May 28, 2008 29
May 28, 2008 30
STATE OF ILLINOIS EXTENT OF PLAY AGREEMENT FOR THE QUAD CITIES STATION EXERCISE August 27, 2008 Criteria that can be re-demonstrated immediately for credit, at the discretion of the evaluator, include the following: 3.a.1, 3.d.1, 3.d.2, 6.a.1, 6.b.1, 6.c.1 and 6.d.1. Criteria that may be re-demonstrated, as approved on a case-by-case basis by the Chairperson of the Regional Assistance Committee, include the following: 2.a.1, 2.b.1, 2.b.2, 5.a.1 and 5.b.1.
EVALUATION AREA 1 - EMERGENCY OPERATIONS MANAGEMENT Criterion 1.a.1: OROs use effective procedures to alert, notify and mobilize emergency personnel and activate facilities in a timely manner.
The State Emergency Operations Center (SEOC), which houses the IEMA Communications Center (Initial Warning Point), the State of Illinois Response Center (SIRC) and the Radiological Emergency Assessment Center (REAC), will be activated. The IEMA Emergency Response Telecommunicator will implement procedures for notification of IEMA staff as defined in IEMA SOPs. The SIRC will be partially activated with IEMA personnel. REAC will be fully activated.
Rosters will be provided to demonstrate 24-hour staffing of the SIRC and REAC. The evaluator will not be allowed to remove the rosters.
The Unified Area Command (UAC) will be activated at the Whiteside County Airport with State district and regional personnel. The Radiological Assessment Field Team (RAFT) Command Center and mobile lab will be staffed at the IDOT Yard near Lyndon for training purposes. IEMA personnel will be prepositioned in the local area and dispatched to the Rock Island County EOC, Whiteside County EOC, UAC, Emergency Operations Facility (EOF), Technical Support Center (TSC) and the Joint Information Center (JIC). FEMA will not evaluate the TSC.
The prepositioned State staff will begin exercise play no earlier than the Alert.
Criterion 1.b.1: Facilities are sufficient to support the emergency response.
This criterion will not be demonstrated during this exercise.
Criterion 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.
The ability to direct and control emergency response activities will be demonstrated at the SIRC, REAC, the UAC and the JIC. Coordination will be demonstrated between the SIRC, the REAC, the UAC, the JIC, the EOF and the County EOCs.
Criterion 1.d.1: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations.
IEMA will use a variety of communication systems [Nuclear Accident Reporting System (NARS),
telefax, commercial telephone, cellular phone, radio] to communicate with other organizations and locations.
Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI) and other supplies are sufficient to support emergency operations.
The State of Illinois will demonstrate the use of equipment, maps and displays to support emergency operations. DCO logs will be available from an IEMA Radiological Advisors in the County EOCs.
May 28, 2008 31
A DCO briefing/traffic and access control (TAC) interview will be conducted by Illinois State Police on August 26 (tentative) at the District 7 Headquarters in East Moline. During this event, the availability of dosimetry will be demonstrated. No more than 10% of ISP District 7 dosimetry kits will be inspected during the interview to confirm serial numbers.
EVALUATION AREA 2 - PROTECTIVE ACTION DECISION MAKING Criterion 2.a.1: OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.
The ability to make the decision to recommend the use of KI to emergency workers will be demonstrated in REAC. A message will be injected in the Rock Island County EOC to drive the decision to authorize exposure in excess of administrative limits.
Criterion 2.b.1: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data and licensee and ORO dose projections, as well as knowledge of on-site and off-site environmental conditions.
The REAC will evaluate the licensee information and complete independent dose projections based on that information and simulated field monitoring data. REAC will make an evaluation of the data and make a protective action recommendation (PAR) to the SIRC.
Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy).
The coordination to determine PARs based upon available shelters, evacuation time estimates and other relevant factors will be demonstrated between the SIRC and REAC. The State PAR will be transmitted to the EPZ counties via NARS.
The capability to determine which centers should be activated for monitoring, decontamination, registration reception and congregate care will be demonstrated at UAC, with input from the SIRC and REAC.
Criterion 2.c.1: Protective action decisions are made, as appropriate, for special population groups.
The coordination to determine PARs based upon available shelters, evacuation time estimates and other relevant factors will be demonstrated between the SIRC and REAC. The State PAR will be transmitted to the EPZ counties via NARS.
The ability to make the decision to recommend the use of KI to institutionalized persons will be demonstrated in REAC.
Criterion 2.d.1: Radiological consequences for the ingestion pathway are assessed and appropriate protective action decisions are made based on the OROs planning criteria.
This criterion will not be demonstrated during this exercise.
Criterion 2.e.1: Timely re-location, re-entry and return decisions are made and coordinated as appropriate, based on assessments of the radiological conditions and criteria in the OROs plan and/or procedures.
This criterion will not be demonstrated during this exercise.
May 28, 2008 32
EVALUATION AREA 3 - PROTECTIVE ACTION IMPLEMENTATION Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plan and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.
This will be demonstrated during the DCO briefing/TAC interview on August 26 (tentative), at the ISP District 7 Headquarters.
Criterion 3.b.1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals (not the general public) is maintained.
This will be demonstrated during the DCO briefing/TAC interview on August 26 (tentative), at the ISP District 7 Headquarters.
Criterion 3.c.1: Protective action decisions are implemented for special population groups within areas subject to protective actions.
This criterion does not apply to the State of Illinois.
Criterion 3.c.2: OROs/School officials decide upon and implement protective actions for schools.
This criterion does not apply to the State of Illinois.
Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.
This will be demonstrated by the State through coordination between the UAC and the County EOCs, in accordance with the Quad Cities Station EPZ Traffic and Access Control procedures.
The staffing of the State posts will be simulated during the exercise. A TAC interview will be conducted on August 26 (tentative) at ISP District 7 Headquarters.
Criterion 3.d.2: Impediments to evacuation are identified and resolved.
This will be demonstrated through discussions at the UAC between the ISP and Illinois Department of Transportation. A message will be injected to the ISP representative in the Rock Island County EOC that will drive this demonstration. State personnel will deal with the impediment by discussing the need for equipment, and its estimated time of arrival, etc. Actual contacts with resource providers will be made and logged.
Criterion 3.e.1: The ORO demonstrates the availability and appropriate use of adequate information regarding water, food supplies, milk and agricultural production within the ingestion exposure pathway emergency planning zone for implementation of protective actions.
This criterion will not be demonstrated during this exercise.
Criterion 3.e.2: Appropriate measures, strategies and pre-printed instructional material are developed for implementing protective action decisions for contaminated water, food products, milk and agricultural production.
This criterion will not be demonstrated during this exercise.
Criterion 3.f.1: Decisions regarding controlled re-entry of emergency workers and relocation and return of the public are coordinated with appropriate organizations and implemented.
May 28, 2008 33
This criterion will not be demonstrated during this exercise.
EVALUATION AREA 4 - FIELD MEASUREMENT AND ANALYSIS Criterion 4.a.1: The field teams are equipped to perform field measurements of direct radiation exposure (cloud and ground shine) and to sample airborne radioiodine and particulates.
This criterion will not be demonstrated during this exercise.
Criterion 4.a.2: Field teams are managed to obtain sufficient information to help characterize the release and to control radiation exposure.
This criterion will not be demonstrated during this exercise.
Criterion 4.a.3: Ambient radiation measurements are made and recorded at appropriate locations, and radioiodine and particulate samples are collected. Teams will move to an appropriate low background location to determine whether any significant (as specified in the plan and/or procedures) amount of radioactivity has been collected on the sampling media.
This criterion will not be demonstrated during this exercise.
Criterion 4.b.1: The field teams demonstrate the capability to make appropriate measurements and to collect appropriate samples (e.g., food crops, milk, water, vegetation, and soil) to support adequate assessments and protective action decision-making.
This criterion will not be demonstrated during this exercise.
Criterion 4.c.1: The laboratory is capable of performing required radiological analyses to support protective action decisions.
This criterion will not be demonstrated during this exercise.
EVALUATION AREA 5 - EMERGENCY NOTIFICATION AND PUBLIC INFORMATION Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance.
The State's role in demonstrating this criterion is limited to transmitting the State's PAR to the counties and monitoring the instructional messages provided to the public by the counties. This monitoring will be accomplished by IEMA representatives in the County EOCs.
Criterion 5.a.2: [RESERVED]
Criterion 5.a.3: Activities associated with FEMA approved exception areas (where applicable) are completed within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. Backup alert and notification of the public is completed within 45 minutes following the detection by the ORO of a failure of the primary alert and notification system.
This criterion does not apply to the State of Illinois.
Criterion 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.
This will be demonstrated at the JIC in coordination with the SIRC, REAC, UAC and the County EOCs. IEMA personnel will be present at the JIC to coordinate with the Exelon staff. Media May 28, 2008 34
briefings will be conducted at the JIC. A livestock advisory will be issued to the media from the JIC or the SIRC when appropriate.
A rumor control phone bank for public inquiries will not be operated by the State during the exercise.
EVALUATION AREA 6 - SUPPORT OPERATION/FACILITIES Criterion 6.a.1: The reception center/emergency worker facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees and/or emergency workers.
Both of the facilities designated as reception and congregate care centers in IPRA-Quad Cities have been evaluated since 2004. For this reason, an interview and inspections will not be conducted during the week of the Quad Cities exercise.
Criterion 6.b.1: The facility/ORO has adequate procedures and resources for the accomplishment of monitoring and decontamination of emergency worker equipment including vehicles.
Both of the facilities designated as reception and congregate care centers in IPRA-Quad Cities have been evaluated since 2004. For this reason, an interview and inspections will not be conducted during the week of the Quad Cities exercise.
Criterion 6.c.1: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with American Red Cross planning guidelines.
Managers demonstrate the procedures to assure that evacuees have been monitored for contamination and have been decontaminated as appropriate prior to entering congregate care facilities.
Both of the facilities designated as reception and congregate care centers in IPRA-Quad Cities have been evaluated since 2004. For this reason, an interview and inspections will not be conducted during the week of the Quad Cities exercise.
Criterion 6.d.1: The facility/ORO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals.
This criterion will be demonstrated during a drill at Trinity Medical Center - West in Rock Island on August 26, at 1 p.m. (confirmed).
May 28, 2008 35
ROCK ISLAND COUNTY EXTENT OF PLAY AGREEMENT FOR THE QUAD CITIES STATION EXERCISE August 27, 2008 Criteria that can be re-demonstrated immediately for credit, at the discretion of the evaluator, include the following: 3.a.1, 3.d.1, 3.d.2, 6.a.1, 6.b.1, 6.c.1 and 6.d.1. Criteria that may be re-demonstrated, as approved on a case-by-case basis by the Chairperson of the Regional Assistance Committee, include the following: 2.a.1, 2.b.1, 2.b.2, 5.a.1 and 5.b.1.
EVALUATION AREA 1 - EMERGENCY OPERATIONS MANAGEMENT Criterion 1.a.1: OROs use effective procedures to alert, notify and mobilize emergency personnel and activate facilities in a timely manner.
Rock Island County intends to fully activate the Emergency Operations Center (EOC) in Milan, Illinois. The County will implement notification procedures as defined in IPRA-Quad Cities.
Representatives from IEMA, ISP and Exelon will staff the County EOC but will not be pre-positioned in the EOC. A rooster will be provided to demonstrate 24-hour staffing of the EOC.
Evaluators will not be allowed to remove the roster from the EOC.
An evaluator will be positioned at the County Sheriffs Communications Center (initial warning point) at the start of the exercise.
Criterion 1.b.1: Facilities are sufficient to support the emergency response.
This criterion will not be demonstrated in the Rock Island County EOC.
Criterion 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.
Decision making will be demonstrated at the Rock Island County EOC. Coordination of decisions and emergency activities will be demonstrated between Rock Island County, the SIRC, the UAC, the JIC, and between the County and municipalities within the EPZ. Coordination between Rock Island County and Whiteside County will be demonstrated.
Criterion 1.d.1: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations.
Rock Island County will use NARS, commercial telephone, radio and telefax to communicate with departments and agencies at other locations.
Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI) and other supplies are sufficient to support emergency operations.
Rock Island County will demonstrate the ability to support operations through the use of maps, status boards and other displays as appropriate. DCO logs will be available from the IEMA Radiological Advisor in the County EOC. The availability of dosimetry and KI will be demonstrated at the County EOC and during the traffic and access control (TAC) demonstration.
The DCO briefing for the deputy demonstrating traffic and access control will be conducted at the Rock Island County EOC.
May 28, 2008 36
May 28, 2008 EVALUATION AREA 2 - PROTECTIVE ACTION DECISION MAKING Criterion 2.a.1: OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.
This criterion does not apply to Rock Island County.
Criterion 2.b.1: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data and licensee and ORO dose projections, as well as knowledge of on-site and off-site environmental conditions.
This criterion does not apply to Rock Island County.
Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy).
The State of Illinois will make protective action recommendations (PARs) to Rock Island County officials in the County EOC. The Rock Island County officials will make the final decision regarding what protective actions will be recommended to the public.
Criterion 2.c.1: Protective action decisions are made, as appropriate, for special population groups.
The State of Illinois will make PARs to Rock Island County officials in the County EOC. The Rock Island County officials will make the final decision regarding what protective actions will be recommended to the special population groups.
Criterion 2.d.1: Radiological consequences for the ingestion pathway are assessed and appropriate protective action decisions are made based on the OROs planning criteria.
This criterion does not apply to Rock Island County.
Criterion 2.e.1: Timely re-location, re-entry and return decisions are made and coordinated as appropriate, based on assessments of the radiological conditions and criteria in the OROs plan and/or procedures.
This criterion will not be demonstrated during this exercise.
EVALUATION AREA 3 - PROTECTIVE ACTION IMPLEMENTATION Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plan and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.
Rock Island County will demonstrate this criterion by coordination with the IEMA Radiological Advisor and timely dissemination and exchange of information within the County Dosimetry Control Officer network. Exercise messages will be injected which will ensure the opportunity to demonstrate this criterion in the County EOC.
This criterion will also be demonstrated during the TAC demonstration. The DCO briefing for the Sheriffs deputy demonstrating traffic and access control will be conducted at the Rock Island County EOC.
37
March 5, 2008 Criterion 3.b.1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals (not the general public) is maintained.
When notified by the State of Illinois to distribute and administer KI, Rock Island County officials will discuss the issuance of KI to emergency workers and immobile populations, as a voluntary measure, and will notify the municipalities of the State's recommendation.
This criterion will also be demonstrated during the TAC demonstration. The DCO briefing for the Sheriffs deputy demonstrating traffic and access control will be conducted at the Rock Island County EOC.
Criterion 3.c.1: Protective action decisions are implemented for special population groups within areas subject to protective actions.
This will be demonstrated by Rock Island County through the simulated implementation of the appropriate procedures. The appropriate officials will coordinate transportation and receiving facilities for special populations. One of each type of special facility will be contacted during the exercise. One of each type of transportation provider (ambulance/bus) will be contacted during the exercise. The public will not be involved in the demonstration.
The Mobility Impaired List will be available for inspection in the County EOC during the exercise.
The evaluator will not be allowed to remove the list from the EOC.
Criterion 3.c.2: OROs/School officials decide upon and implement protective actions for schools.
Rock Island County officials will demonstrate this capability through the simulated implementation of the appropriate procedures in the County EOC. The EPZ schools and transportation providers will be contacted during the exercise.
A successful interview with Riverdale School District staff was conducted in 2006. Therefore, an interview will not be conducted this year.
Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.
Coordination between Rock Island County agencies designated to provide traffic and access control will be exhibited in the County EOC. A Sheriffs deputy will be available during the exercise to demonstrate the staffing of one post. The post for the demonstration will be selected by Rock Island County during the exercise based on exercise play. The deputy will drive to the selected post location for the demonstration. The staffing of the remaining posts will be simulated.
Criterion 3.d.2: Impediments to evacuation are identified and resolved.
The Rock Island County EOC staff will demonstrate the capability to identify and take appropriate actions concerning impediments to evacuation. A message will be injected by the Controller that will drive this demonstration. County personnel will deal with the impediment by identifying the equipment needed, discussing its estimated time of arrival, etc. Actual contacts with resource providers will made and logged.
Criterion 3.e.1: The ORO demonstrates the availability and appropriate use of adequate information regarding water, food supplies, milk and agricultural production within the ingestion exposure pathway emergency planning zone for implementation of protective actions.
This criterion does not apply to Rock Island County.
38
March 5, 2008 Criterion 3.e.2: Appropriate measures, strategies and pre-printed instructional material are developed for implementing protective action decisions for contaminated water, food products, milk and agricultural production.
This criterion does not apply to Rock Island County.
Criterion 3.f.1: Decisions regarding controlled re-entry of emergency workers and relocation and return of the public are coordinated with appropriate organizations and implemented.
This criterion will not be demonstrated during this exercise.
EVALUATION AREA 4 - FIELD MEASUREMENT AND ANALYSIS This evaluation area does not apply to Rock Island County.
EVALUATION AREA 5 - EMERGENCY NOTIFICATION AND PUBLIC INFORMATION Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance.
Rock Island County will demonstrate the capability to provide both an alert signal and an initial instructional message to populated areas throughout the 10-mile plume pathway EPZ in a timely manner after their decision to activate the alert and notification system to implement PARs.
This capability will be demonstrated through the simulated activation of the Quad Cities Station EPZ Prompt Notification System as defined in IPRA-Quad Cities. The Prompt Notification System (outdoor warning sirens) will not be activated during the exercise.
The ability to provide instructions to the public will be demonstrated through the simulated activation of the local radio station. The local radio station will be contacted for the first, and possibly the second, alert and notification sequence. An evaluator and controller will be positioned at the radio station during the exercise to monitor the messages. If the initial message does not contain a protective action recommendation, the evaluator and controller will stay at the radio station for the second message.
Coordination between Rock Island County and Whiteside County will be demonstrated.
Criterion 5.a.2: [RESERVED]
Criterion 5.a.3: Activities associated with FEMA approved exception areas (where applicable) are completed within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. Backup alert and notification of the public is completed within 45 minutes following the detection by the ORO of a failure of the primary alert and notification system.
This criterion does not apply to Rock Island County.
Criterion 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.
Rock Island County will demonstrate this criterion by using pre-scripted messages as indicated in IPRA-Quad Cities. Contact with the radio station will be simulated for each alert and notification sequence following the sequence issuing the initial PAR.
39
March 5, 2008 The ability to provide information to the media will be demonstrated by Rock Island County through a briefing held at the Rock Island County media briefing location. If real media are not present for the briefing, the controller and observers will serve as mock media. Evaluators will not serve as mock media.
The ability to deal with rumors will be demonstrated by Rock Island County through coordination between the County EOC and the JIC. The Rock Island County EOC controller will inject exercise messages which will ensure the opportunity to demonstrate this criterion. County officials will investigate and address rumors. If appropriate, the rumors will be coordinated between State and County officials in the County EOC and the JIC.
County emergency broadcast messages and news releases, if issued, will be faxed to the JIC.
EVALUATION AREA 6 - SUPPORT OPERATION/FACILITIES This evaluation area does not apply to Rock Island County.
40
May 28, 2008 WHITESIDE COUNTY EXTENT OF PLAY AGREEMENT FOR THE QUAD CITIES STATION EXERCISE August 27, 2008 Criteria that can be re-demonstrated immediately for credit, at the discretion of the evaluator, include the following: 3.a.1, 3.d.1, 3.d.2, 6.a.1, 6.b.1, 6.c.1 and 6.d.1. Criteria that may be re-demonstrated, as approved on a case-by-case basis by the Chairperson of the Regional Assistance Committee, include the following: 2.a.1, 2.b.1, 2.b.2, 5.a.1 and 5.b.1.
EVALUATION AREA 1 - EMERGENCY OPERATIONS MANAGEMENT Criterion 1.a.1: OROs use effective procedures to alert, notify and mobilize emergency personnel and activate facilities in a timely manner.
Whiteside County intends to fully activate the Emergency Operations Center (EOC) in Morrison, Illinois. The County will implement notification procedures as defined in IPRA-Quad Cities.
Representatives from IEMA, ISP and Exelon will staff the County EOC but will not be pre-positioned in the EOC. A roster will be provided to demonstrate 24-hour staffing of the EOC.
Evaluators will not be allowed to remove the roster from the EOC.
An evaluator will be positioned at the County Sheriffs Communications Center (initial warning point) at the start of the exercise.
Criterion 1.b.1: Facilities are sufficient to support the emergency response.
This criterion will not be demonstrated in the Whiteside County EOC.
Criterion 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.
Decision making will be demonstrated at the Whiteside County EOC. Coordination of decisions and emergency activities will be demonstrated between Whiteside County, the SIRC, the UAC, the JIC, and between the County and Albany. Coordination between Whiteside County and Rock Island County will be demonstrated.
Criterion 1.d.1: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations.
Whiteside County will use NARS, commercial telephone, radio and telefax to communicate with departments and agencies at other locations.
Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI) and other supplies are sufficient to support emergency operations.
Whiteside County will demonstrate the ability to support operations through the use of maps, status boards and other displays as appropriate. DCO logs will be available from the IEMA Radiological Advisor in the County EOC. The availability of dosimetry and KI will be demonstrated at the County EOC and during the traffic and access control (TAC) demonstration.
The DCO briefing for the deputy demonstrating traffic and access control will be conducted at the Whiteside County EOC.
EVALUATION AREA 2 - PROTECTIVE ACTION DECISION MAKING 41
May 28, 2008 Criterion 2.a.1: OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.
This criterion does not apply to Whiteside County.
Criterion 2.b.1: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data and licensee and ORO dose projections, as well as knowledge of on-site and off-site environmental conditions.
This criterion does not apply to Whiteside County.
Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy).
The State of Illinois will make protective action recommendations (PARs) to Whiteside County officials in the County EOC. The Whiteside County officials will make the final decision regarding what protective actions will be recommended to the public.
Criterion 2.c.1: Protective action decisions are made, as appropriate, for special population groups.
The State of Illinois will make PARs to Whiteside County officials in the County EOC. The Whiteside County officials will make the final decision regarding what protective actions will be recommended to the special population groups.
Criterion 2.d.1: Radiological consequences for the ingestion pathway are assessed and appropriate protective action decisions are made based on the OROs planning criteria.
This criterion does not apply to Whiteside County.
Criterion 2.e.1: Timely re-location, re-entry and return decisions are made and coordinated as appropriate, based on assessments of the radiological conditions and criteria in the OROs plan and/or procedures.
This criterion will not demonstrated during this exercise.
EVALUATION AREA 3 - PROTECTIVE ACTION IMPLEMENTATION Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plan and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.
Whiteside County will demonstrate this criterion by coordination with the IEMA Radiological Advisor and timely dissemination and exchange of information within the County Dosimetry Control Officer network. Exercise messages will be injected which will ensure the opportunity to demonstrate this criterion in the County EOC.
This criterion will also be demonstrated during the (TAC) demonstration. The DCO briefing for the Sheriffs deputy demonstrating traffic and access control will be conducted at the Whiteside County EOC.
42
Criterion 3.b.1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals (not the general public) is maintained.
When notified by the State of Illinois to distribute and administer KI, Whiteside County officials will discuss the issuance of KI to emergency workers and immobile populations, as a voluntary measure, and will notify Albany officials of the State's recommendation.
This criterion will also be demonstrated during the TAC demonstration. The DCO briefing for the Sheriffs deputy demonstrating traffic and access control will be conducted at the Whiteside County EOC.
Criterion 3.c.1: Protective action decisions are implemented for special population groups within areas subject to protective actions.
This will be demonstrated by Whiteside County through the simulated implementation of the appropriate procedures. The appropriate officials will coordinate transportation and receiving facilities for special populations. One of each type of special facility will be contacted during the exercise. One of each type of transportation provider (ambulance/bus) will be contacted during the exercise. The public will not be involved in the demonstration.
The Mobility Impaired List will be available for inspection in the County EOC during the exercise.
The evaluator will not be allowed to remove the list from the EOC.
Criterion 3.c.2: OROs/School officials decide upon and implement protective actions for schools.
This criterion will be demonstrated in the Whiteside County EOC.
Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.
Coordination between Whiteside County agencies designated to provide traffic and access control will be exhibited in the County EOC. A Sheriffs deputy will be available during the exercise to demonstrate the staffing of one post. The post for the demonstration will be selected by Whiteside County during the exercise based on exercise play. The deputy will drive to the selected post location for the demonstration. The staffing of the remaining posts will be simulated.
Criterion 3.d.2: Impediments to evacuation are identified and resolved.
The Whiteside County EOC staff will demonstrate the capability to identify and take appropriate actions concerning impediments to evacuation. A message will be injected by the Controller that will drive this demonstration. County personnel will deal with the impediment by identifying the equipment needed, discussing its estimated time of arrival, etc. Actual contacts with resource providers will be made and logged.
Criterion 3.e.1: The ORO demonstrates the availability and appropriate use of adequate information regarding water, food supplies, milk and agricultural production within the ingestion exposure pathway emergency planning zone for implementation of protective actions.
This criterion does not apply to Whiteside County.
Criterion 3.e.2: Appropriate measures, strategies and pre-printed instructional material are developed for implementing protective action decisions for contaminated water, food products, milk and agricultural production.
43
This criterion does not apply to Whiteside County.
Criterion 3.f.1: Decisions regarding controlled re-entry of emergency workers and relocation and return of the public are coordinated with appropriate organizations and implemented.
This criterion will not be demonstrated during this exercise.
EVALUATION AREA 4 - FIELD MEASUREMENT AND ANALYSIS This evaluation area does not apply to Whiteside County.
EVALUATION AREA 5 - EMERGENCY NOTIFICATION AND PUBLIC INFORMATION Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance.
Whiteside County will demonstrate the capability to provide both an alert signal and an initial instructional message to populated areas throughout the 10-mile plume pathway EPZ in a timely manner after their decision to activate the alert and notification system to implement PARs.
This capability will be demonstrated through the simulated activation of the Quad Cities Station EPZ Prompt Notification System as defined in IPRA-Quad Cities. The Prompt Notification System (outdoor warning sirens) will not be activated during the exercise.
The ability to provide instructions to the public will be demonstrated through the simulated activation of the local radio station (WSDR/WZZT/WSSQ). The local radio station will be contacted during the first, and possibly the second, alert and notification sequence. An evaluator and controller will be positioned at the radio station during the exercise to monitor the messages.
If the initial message does not contain a protective action recommendation, the evaluator and controller will stay at the radio station for the second message.
Coordination between Whiteside County and Rock Island County will be demonstrated.
Criterion 5.a.2: [RESERVED]
Criterion 5.a.3: Activities associated with FEMA approved exception areas (where applicable) are completed within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. Backup alert and notification of the public is completed within 45 minutes following the detection by the ORO of a failure of the primary alert and notification system.
This criterion does not apply to Whiteside County.
Criterion 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.
Whiteside County will demonstrate this criterion by using pre-scripted messages as indicated in IPRA-Quad Cities. Contact with the radio station will be simulated for each alert and notification sequence following the sequence issuing the initial PAR.
The ability to provide information to the media will be demonstrated by Whiteside County through a briefing held at the Whiteside County media briefing location. If real media are not present for the briefing, the controller and observers will serve as mock media. Evaluators will not serve as mock media.
44
The ability to deal with rumors will be demonstrated by Whiteside County through coordination between the County EOC and the JIC. The Whiteside County EOC controller will inject exercise messages which will ensure the opportunity to demonstrate this criterion. County officials will investigate and address rumors. If appropriate, the rumors will be coordinated between State and County officials in the County EOC and the JIC.
County emergency broadcast messages and news releases, if issued, will be faxed to the JIC.
EVALUATION AREA 6 - SUPPORT OPERATION/FACILITIES This evaluation area does not apply to Whiteside County.
45
APPENDIX 4 EXERCISE SCENARIO This appendix contains a summary of the simulated sequence of events -- Exercise Scenario -- which was used as the basis for invoking emergency response actions by Offsite Response Organizations in the Quad Cities REP Partial Participation Plume Exposure Pathway exercise on August 27, 2008.
This exercise scenario was submitted by the State of Illinois and Exelon Nuclear and approved by DHS/FEMA Region V on July 30, 2008.
During the exercise, controllers from the State of Illinois gave inject messages, containing scenario events and/or relevant data to those persons or locations who would normally receive notification of such events. These inject messages were the method used for invoking response actions by OROs.
46
47