ML11112A128
| ML11112A128 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 04/19/2011 |
| From: | Gillespie T Duke Energy Carolinas |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML11112A128 (36) | |
Text
- "
Duke Energy/
April 19, 2011 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555 T. PRESTON GILLESPIE, JR.
Vice President Oconee Nuclear Station Duke Energy ONOI VP / 7800 Rochester Hwy.
Seneca, SC 29672 864-873-4478 864-873-4208 fax T. Gillespie@duke-energy. com
Subject:
Duke Energy Carolinas, LLC Oconee Nuclear Site Docket Number 50-287 Core Operating Limits Report (COLR)
Attached, pursuant to Oconee Technical Specification 5.6.5.d, is an information copy of a revision to the Core Operating Limits Report for Oconee Unit 1, Cycle 27, Revision 32.
If you have any questions, please direct them to Judy Smith at 864-873-4309.
Sincerely, T. Preston Gillespie, Jr.
Vice President Oconee Nuclear Station Attachment
/1007 www. duke-energy, com
U.S. Nuclear Regulatory Commission April 19, 2011 Page 2 xc w/att:
Mr. Victor McCree, Regional Administrator U.S. Nuclear Regulatory Commission, Region II Marquis One Tower 245 Peachtree Center Ave., NE, Suite 1200 Atlanta, GA 30303-1257 Mr. John Stang Project Manager U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Mail Stop 8 G9A Washington, DC 20555 Mr. Andrew Sabisch Senior Resident Inspector Oconee Nuclear Site
PRIORITY SuperRush DISPOSmON OF THE ORIGINAL DOCUMENT WILL BE TO THE TRANSMITTAL SIGNATURE UNLESS RECIPIENT IS OTHERWISE IDENTIFIED BELOW
- 1) 00813 DOC MGMT EC04T ORIGINAL
.2) 06358 ONS REGUL COMPLIANCE ON03RC
- 3) 06700 ONS MANUAL MASTER FILE ON03DM
- 4) 06937 R R ST CLAIR EC08G FOR INFORMATION ONLY Duke Energy DOCUMENT TRANSMITTAL FORM Date:
03124111 Document Transmittal #:
DUK110830042 QA CONDITION U Yes No OTHER ACKNOWLEDGEMENT REQUIRED D Yes IF OA OR OTHER ACKNOWLEDGEMENT REQUIRED, PLEASE ACKNOWLEDGE RECEIPT BY RETURNING THIS FORM TO:
Duke Energy P.O. Box 1006 Energy Center EC04T Charlotte, N.C.
28201-1006 REFERENCE NUCLEAR GENERAL OFFICE OCONEE NUCLEAR STATION RESP GROUP: NE RECORD RETENTION: 421734 OCONEE 1 CYCLE 27 CORE OPERATING LIMITS REPORT Page 1 of 1 JQA.k 1Ž9~}AAL~>
Recd By
"-'U
~2~J~62 Date DOCUMENT NO QA COND REV #/ DATE DISTR CODE 1
2 3
4 5
6 7
8 9
10 11 12 113 14 15 TOTAL 4
+-+-4
+
~
ONEI-0400-050 SEE REMARKS I
032 03/24/11 II II II II NOMD-27 Vi Vi 3
REMARKS: DUKE DOCUMENTS CREATED UNDER EDM-501 ARE EXCLUDED FROM THE EDM-601 PROCESS PER NSD-301, SECTION 2.4 THEREFORE, THE EXEMPTION CODE OR PIP NUMBER REQUIRED BY EDM-601 IS NOT REQUIRED FOR THIS DOCUMENT.
DAVID A BAXTER VICE PRESIDENT NUCLEAR ENGINEERING BY:
D S ORR DSO/TER EC08G
ONEI-0400-50 Rev 32 Page 1 of 33 Duke Energy Oconee 1 Cycle 27 Core Operating Limits Report QA Condition 1 0
6b6 Date:
3 Z3-)I Prepared By:
D.S. Orr L.C. James II 4-GIU.
Reviewed By:
Date: 22MAA*940
/
CDR By:
M.C Handrick A4 C.
Date 3/2/-3,//
.r R. StCClair Date:.
1-Z, Date :
Approved By:
Document No. / Rev.
ONEI-0400-50 Rev. 32 Date March, 2011 Page No.
Page 2 of 33 INSPECTION OF ENGINEERING INSTRUCTIONS Inspection Waived By:
Date:
.3ARVPI (Sponsor)
CATAWBA Inspection Waived MCE (Mechanical & Civil) 11 Inspected By/Date:
RES (Electrical Only)
E]
Inspected By/Date:
RES (Reactor)
[]
Inspected By/Date:
MOD El Inspected By/Date:
Other ( __
)
Inspected By/Date:
OCONEE Inspection Waived MCE (Mechanical & Civil)
[]
Inspected By/Date:
RES (Electrical Only)
[]
Inspected By/Date:
RES (Reactor)
[]
Inspected By/Date:
MOD Inspected By/Date:
Other ( __
)
Inspected By/Date:
MCGUIRE Inspection Waived MCE (Mechanical & Civil)
E]
Inspected By/Date:
RES (Electrical Only)
E]
Inspected By/Date:
RES (Reactor)
El Inspected By/Date:
MOD El Inspected By/Date:
Other (
E) L Inspected By/Date:
ONEI-0400-50 Rev 32 Page 3 of 33 Oconee 1 Cycle 27 Core Operating Limits Report Insertion Sheet for Revision 32 This revision is not valid until the end of operation for Oconee 1 Cycle 26.
Remove these Revision 31 pages Insert these Revision 32 pages 1-33 1-33 Revision Log Effective Pages Pages Pages Total Effective Revision Date Revised Added Deleted Pages Oconee 1 Cycle 27 revisions below 32 Mar-11 1 -33 33 Oconee 1 Cycle 26 revisions below 31 Nov-09 1 -33 33 30 Nov-09 1 -33 33 29 Nov-09 1 - 33 33 28 Sep 09 1 -33 33 lOconee 1 Cycle 25 revisions below 27 Apr2008 1 -33 33 Oconee 1 Cycle 24 revisions below 26 Oct 2006 1-33 33 1Oconee 1 Cycle 23 revisions below 25 Apr2005 1 -33 33
ONEI-0400-50 Rev 32 Page 4 of 33 Oconee 1 Cycle 27 1.0 Error Adjusted Core Operating Limits The Core Operating Limits Report for 01C27 has been prepared in accordance with the requirements of TS 5.6.5. The core operating limits within this report have been developed using NRC approved methodology identified in references 1 through 11. The RPS protective limits and maximum allowable setpoints are documented in references 12 through 14. These limits are validated for use in O1C27 by references 15 through 17. The O1C27 analyses assume a design flow of 108.5% of 88,000 gpm per RCS pump, radial local peaking (FAh) of 1.714, an axial peaking factor (Fz) of 1.5, and an EOC
(< 100 ppmB) Tavg reduction for up to 10°F provided 4 RCPs are in operation and Tavg does not decrease below 569°F.
The error adjusted core operating limits included in section 1 of the report incorporate all necessary uncertainties and margins required for operation of the 01C27 reload core.
1.1 References
- 1. Nuclear Design Methodology Using CASMO-3 / SIMULATE-3P, DPC-NE-1004-A, Revision la, January, 2009.
- 2. Oconee Nuclear Station Reload Design Methodology II, DPC-NE-1 002-A, Revision 3b, June 2009.
- 3. Oconee Nuclear Station Reload Design Methodology, NFS-1001A, Revision 6a, June 2009.
- 4. ONS Core Thermal Hydraulic Methodology Using VIPRE-01, DPC-NE-2003-PA, Revision 2a, December 2008.
- 5. Thermal Hydraulic Statistical Core Design Methodology, DPC-NE-2005-PA, Revision 4a, December 2008.
- 6. Fuel Mechanical Reload Analysis Methodology Using TACO3, DPC-NE-2008-PA, Revision la, December 2008.
- 8. Thermal Hydraulic Transient Analysis Methodology, DPC-NE-3000-PA, Rev. 4a, July 2009.
- 9. BAW-10192-PA, BWNT LOCA - BWNT Loss of Coolant Accident Evaluation Model for Once-Through Steam Generator Plants, Rev. 0, SER dated February 18, 1997.
- 10. BAW-10164P-A, Rev. 4 and 6, RELAP5/MOD2-B&W - An Advanced Computer Program for Light Water Reactor LOCA and Non-LOCA Transient Analysis, SERs dated April 9, 2002 and June 25, 2007, respectively.
- 11. BAW-1 0227-PA, Evaluation of Advanced Cladding and Structural Material (M5) in PWR Reactor Fuel, Rev. 1, June 2003 (SER to BAW-10186P-A dated June 18, 2003).
- 12. Digital RPS RCS Pressure & Temperature Trip Function Uncertainties and Variable Low RCS Pressure Safety Limit, OSC-8828, Revision 3, October 2010.
- 13. Power Imbalance Safety Limits and Tech Spec Setpoints Using Error Adjusted Flux-Flow Ratio of 1.094, OSC-5604, Revision 3, July 2009.
- 14. ATc and EOC Reduced Tavg Operation, OSC-7265, Rev. 1, Duke Power Co., June 2002.
- 15. OLC27 Maneuvering Analysis, OSC-10198, Revision 1, March 2011.
- 16. 01C27 Specific DNB Analysis, OSC-10207, Revision 0, November 2010.
- 17. OLC27 Reload Safety Evaluation, OSC-10227, Revision 0, March 2011.
ONEI-0400-50 Rev 32 Page 5 of 33 Oconee 1 Cycle 27 Miscellaneous Setpoints BWST boron concentration shall be greater than 2400 ppm and less than 3000 ppm.
Referred to by TS 3.5.4.
Spent fuel pool boron concentration shall be greater than 2400 ppm.
Referred to by TS 3.7.12.
The equivalent of at least 1100 cubic feet of 11,000 ppm boron shall be maintained in the CBAST.
Referred to by TS SLC 16.5.13.
CFT boron concentration shall be greater than 1892 ppm. The average boron concentration in the CFT's shall be less than 4000 ppm.
Referred to by TS 3.5.1.
RCS and Refueling canal boron concentration shall be greater than 2220 ppm.
Referred to by TS 3.9.1.
Shutdown Margin (SDM) shall be greater than 1% Ak/k.
Referred to by TS 3.1.1.
Moderator Temperature Coefficient (MTC) shall be less than:
Linear interpolation is valid within the table provided.
Referred to by TS 3.1.3.
MTC x 10-4 AP / *F
+0.70
+0.525 0.00 0.00 0.00
% FP 0
20 80 100 120 Departure from Nucleate Boiling (DNB) parameter for RCS loop pressure shall be Referred to by TS 3.4.1.
4 RCP:
measured hot leg pressure > 2125 psig 3 RCP:
measured hot leg pressure _> 2125 psig DNB parameter for RCS loop average temperature shall be:
Referred to by TS 3.4.1.
The measured Tavg must be less than COLR limits minus instrument uncertainty. ATc is the setpoint value selected by the operators. Values are expanded by linear interpolation on page 33 of this document without instrument uncertainty.
Max Loop Tavg (Incl 2°F unc)
581.0 581.0 1
581.4 581.2 2
581.8 581.4 3
582.1 581.7 4
582.5 581.9 5
582.9 582.1
- This limit is applied to the loop with the lowest loop average temperature consistent with the NOTE in SR 3.4.1.2. All other temperature limits apply to the maximum loop Tavg.
DNB parameter for RCS loop total flow shall be:
Referred to by TS 3.4.1.
4 RCP:
Measured > 109.5.%df 3 RCP:
Measured > 74.7 % of 4 RCP min flow Regulating rod groups shall be withdrawn in sequence starting with group 5, group 6, and finally group 7.
Referred to by TS 3.2.1.
Regulating rod group overlap shall be 25% +/- 5% between two sequential groups.
Referred to by TS 3.2.1.
Misaligned, dropped, or inoperable rods may be excluded from control rod group average calculations when determining if overlap requirements are met as these situations are explicitly addressed by TS 3.1.4 (Control Rod Group Alignment Limits), TS 3.1.5 (Safety Rod Position Limits), and TS 3.2.3 (Quadrant Power Tilt).
ONEI-0400-50 Rev 32 Page 6 of 33 Oconee 1 Cycle 27 Steady State Operating Band Rod Index APSR %WD EFPD Min Max Min Max 0 to 458 292 +/- 5 300 30 40 458 to EOC 292 +/- 5 300 100 100 0
Core Power Level, %FP Full Incore Out of Core Backup Incore Quadrant Power Tilt Setpoints Steady State Transient 30-100 0-30 30-100 0-30 3.50 7.61 7.11 9.40 2.35 6.09 5.63 7.72 2.25 3.87 3.63 4.81 Referred to by TS 3.2.3 Maximum 0- 100 16.55 14.22 10.07 Correlation Slope (CS) 1.15 Referred to by TS 3.3.1 (SR 3.3.1.3).
ONEI-0400-50 Rev 32 Page 7 of 33 Oconee 1 Cycle 27 Variable Low RCS Pressure RPS Setpoints Referred to by TS 3.3.1 2400 2300 2200 (D,
0) 0~
0 (U
2100 2000 1900 1800 0
1700 540 560 580 600 Reactor Coolant Outlet Temperature, OF 620 640
ONEI-0400-50 Rev 32 Page 8 of 33 Oconee 1 Cycle 27 RPS Power Imbalance Setpoints 4 Pumps
% FP 0.0 90.4 107.9 107.9 90.4 0.0
% Imbalance
-33.0
-33.0
-14.4 14.4 33.0 33.0
-33.0
-33.0
-14.4 14.4 33.0 33.0 3 Pumps 0.0 63.1 80.6 80.6 63.1 0.0 Maximum Allowable RPS Power Imbalance Limits 4 Pumps
% FP 0.0 90.0 109.4 109.4 90.0 0.0
% Imbalance
-35.0
-35.0
-14.4 14.4 35.0 35.0
-35.0
-35.0
-14.4 14.4 35.0 35.0 3 Pumps 0.0 62.3 81.7 81.7 62.3 0.0
ONEI-0400-50 Rev 32 Page 9 of 33 Oconee 1 Cycle 27 Operational Power Imbalance Setpoints 4 Pumps
%FP 0.0 80.0 90.0 100.0 102.0 102.0 100.0 90.0 80.0 0.0 0.0 63.1 63.1 77.0 77.0 63.1 63.1 0.0 Full Incore
-28.0
-28.0
-28.0
-17.8
-15.7 15.7 17.8 28.0 28.0 28.0
-28.0
-28.0
-13.2 13.2 28.0 28.0 Backup Incore
-28.0
-28.0
-28.0
-17.8
-15.7 15.7 17.8 28.0 28.0 28.0
-28.0
-28.0
-13.2 13.2 28.0 28.0 Out of Core
-28.0
-28.0
-28.0
-17.8
-15.7 15.7 17.8 28.0 28.0 28.0
-28.0
-28.0
-13.2 13.2 28.0 28.0 3 Pumps
ONEI-0400-50 Rev 32 Page 10 of 33 Oconee 1 Cycle 27 Operational Power Imbalance Setpoints Operation with 4 RCS Pumps, BOC to EOC
% FP I
RPS Trip Full Incore Alarm I
Out of Core Alarm 107.9 107.0 106.0 105.0 104.0 103.0 102.0 101.0 100.0 99.0 98.0 97.0 96.0 95.0 94.0 93.0 92.0 91.0 90.4 90.0 89.0 88.0 87.0 86.0 85.0 84.0 83.0 82.0 81.0 80.0 0.0
-14.4
-15.4
-16.4
-17.5
-18.5
-19.6
-20.7
-21.7
-22.8
-23.9
-24.9
-26.0
-27.0
-28.1
-29.2
-30.2
-31.3
-32.3
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0 14.4 15.4 16.4 17.5 18.5 19.6 20.7 21.7 22.8 23.9 24.9 26.0 27.0 28.1 29.2 30.2 31.3 32.3 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0
-15.7
-16.7
-17.8
-18.8
-19.8
-20.9
-21.9
-22.9
-23.9
-24.9
-26.0
-27.0
-27.6
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0 15.7 16.7 17.8 18.8 19.8 20.9 21.9 22.9 23.9 24.9 26.0 27.0 27.6 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0
-15.7
-16.7
-17.8
-18.8
-19.8
-20.9
-21.9
-22.9
-23.9
-24.9
-26.0
-27.0
-27.6
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0 15.7 16.7 17.8 18.8 19.8 20.9 21.9 22.9 23.9 24.9 26.0 27.0 27.6 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0 28.0
% FP I
RPS Trip Full Incore Alarm Out of Core Alarm ONEI-0400-50 Rev 32 Page 11 of 33 Oconee 1 Cycle 27 Operational Power Imbalance Setpoints Operation with 3 RCS Pumps, BOC to EOC
% FP I
RPS Trip Full Incore Alarm Out of Core Alarm 80.6 80.0 79.0 78.0 77.0 76.0 75.0 74.0 73.0 72.0 71.0 70.0 69.0 68.0 67.0 66.0 65.0 64.0 63.1 63.0 62.0 61.0 60.0 0.0
-14.4
-15.0
-16.1
-17.1
-18.2
-19.3
-20.3
-21.4
-22.4
-23.5
-24.6
-25.6
-26.7
-27.8
-28.8
-29.9
-30.9
-32.0
-33.0
-33.0
-33.0
-33.0
-33.0
-33.0 14.4 15.0 16.1 17.1 18.2 19.3 20.3 21.4 22.4 23.5 24.6 25.6 26.7 27.8 28.8 29.9 30.9 32.0 33.0 33.0 33.0 33.0 33.0 33.0
-13.2
-14.3
-15.3
-16.4
-17.4
-18.5
-19.6
-20.6
-21.7
-22.8
-23.8
-24.9
-25.9
-27.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0 13.2 14.3 15.3 16.4 17.4 18.5 19.6 20.6 21.7 22.8 23.8 24.9 25.9 27.0 28.0 28.0 28.0 28.0 28.0 28.0
-13.2
-14.3
-15.3
-16.4
-17.4
-18.5
-19.6
-20.6
-21.7
-22.8
-23.8
-24.9
-25.9
-27.0
-28.0
-28.0
-28.0
-28.0
-28.0
-28.0 13.2 14.3 15.3 16.4 17.4 18.5 19.6 20.6 21.7 22.8 23.8 24.9 25.9 27.0 28.0 28.0 28.0 28.0 28.0 28.0
- % FP RPS Trip Full Incore Alarm Out of Core Alarm ONEI-0400-50 Rev 32 Page 12 of 33 Oconee 1 Cycle 27 RPS Power Imbalance Setpoints Referred to by TS 3.3.1 Thermal Power Level, %FP 120.0 1
(-14.4,107.9)
(14.4,107.9) 100.0
-M2
= -0.942
=0.942 Acceptable 4 Pump Operation (33.0,90.4)
(-14.4,80.6)
(14.4,80.6)
M1
(-33.0,90.4)
.0.0
-30.0
-20.0
-10.0 0.0 10.0 20.0 30.0 Percent Power Imbalance 40.0
0 S
Oconee 1 Cycle 27 Imbalance Setpoints for 4 Pump Operation, BOC to EOC ONEI-0*
Rev 32 13 of 33 110.0 100.0 N RPS Trip Setpoint Incore & Outcore Alarm RPS Trip Setpoint 90.0 80.0 70.0 0
60.0 U-50.0 C.)
40.0 30.0 20.0 10.0 0.0
-40
-35
-30
-25
-20
-15
-10
-5 0
5 10 15 20 25 30 35 40 Percent Axial Imbalance
0 i
Oconee I Cycle 27 Imbalance Setpoints for 3 Pump Operation, BOC to EOC ONEI-040@Rev 32 Page 14 of 33 110 100 90 80 70 60 50 40 jRPS Trip Setpoint RPS Trip Setpointý core & Outcore Alarrr 0Q-
.4-0 a) a)
CL 30 20 10
-40
-35
-30
-25
-20
-15
-10
-5 0
5 Percent Axial Imbalance 10 15 20 25 30 35 40
ONEI-0400-50 Rev 32 Page 15 of 33 Oconee 1 Cycle 27 4 Pumps 3 Pumps Operational Rod Index Setpoints RI Insertion Setpoint
%FP No Inop Rod 1 Inop Rod 102.0 263.5 283.4 100.0 261.5 281.5 90.0 251.5 271.9 80.0 241.5 262.3 50.0 201.5 233.4 48.0 195.2 231.5 15.0 91.5 165.5 13.0 76.5 161.5 5.0 16.5 93.5 3.0 1.5 76.5 2.8 0.0 74.8 0.0 0.0 51.0 RI Withdrawal Setpoint 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 77.0 75.0 50.0 48.0 15.0 13.0 5.0 3.0 2.8 0.0 237.5 234.8 201.5 195.2 91.5 76.5 16.5 1.5 0.0 0.0 285.2 281.5 235.2 231.5 165.5 161.5 93.5 76.5 74.8 51.0
ONEI-0400-50 Rev 32 Page 16 of 33 Oconee 1 Cycle 27 Shutdown Margin Rod Index Setpoints 4 Pumps 3 Pumps
%FP 102.0 100.0 48.0 13.0 3.0 2.8 0.0 77.0 75.0 48.0 13.0 3.0 2.8 0.0 RI Insertion Setpoint No nop Rod 1 Inop Rod 224.6 283.4 221.5 281.5 141.5 231.5 76.5 161.5 1.5 76.5 0.0 74.8 0.0 51.0 RI Withdrawal Setpoint 300 300 300 300 300 300 300 300 300 300 300 300 300 300 227.4 221.5 141.5 76.5 1.5 0.0 0.0 285.2 281.5 231.5 161.5 76.5 74.8 51.0
Oconee 1 Cycle 27 Rod Index Setpoints 4 Pump Operation, No Inoperable Rods, BOC to EOC ONEI-0400-50 Rev 32 Page 17 of 33 Shutdown Margin Setpoint Operational Alarm Setpoint
% FP CRGP 5 CRGP 6 CRGP 7 1 CRGP 51 CRGP 6 CRGP 7 102 101 99
-- 97 96 95 94 93 91 90 89 88 87 86 100
-100-100 100--_
100-100 100 100
.100 100 100 100 100 100 100 99.8 99.0 98.2 97.5 96.7 95.9 95.2 94.4 93.6 92.9 92.1 91.3 90.6 89.8 89.0 88.2 87.5 24.8 24.0 23.2 22.5 21.7 20.9 20.2 19.4 18.6 17.9 17.1 16.3 15.6 14.8 14.0 13.2 12.5 100 100 100 100
-100 100 100 100 100 100 100 100 100 1O00 1O00 100 100 100 100 100 100 100 100 100 10o 100
-100 ---
100 100 100 100 100 63.5 62.5 61.5 60.5 59.5 58.5 57.5 56.5 55.5 54.5 53.5 52.5 51.5 50.5 49.5 48.5 47.5
-I--
I---
85 84 83 82 100 100 100 100 86.7 85.9 85.2 84.4 11.7 10.9 100 100 100 46.5 100 45.5 44.5 10.2 100 100 9.4 100 100 81 80 79 78 77 76 75 74 73
..-72 71 70 69.8 69 68 67.6 67 66
.65 64 63 62 61 60 59
..58 57 56..
5.5 54 53 51 50 100 100
-100 100-.
100-100 100 100 100 100 100 100 100
__o1060 1006 100 100 100o100-100...
100 100
- 100 100 100
-100 100 10o 100 1o0 106 100 43.5 42.5 83.6 82.9 82.1 81.3 80.6 79.8 79.0 78.2 77.5 76.7 75.9 75.2 75.0 73.8 72.3 71.7 70.7 69.2 67.7 64.6 63.0 60.0 58.4 56.9 55.3 53.8 52.3 50.7 49.2 47.7 46.1 44.6 8.6 7.9 7.1 6.3 5.6 4.8 4.0 3.2 2.5 1.7 0.9 0.2 0
0 0
00 0
0-0 0
0 0
0 0
0 0
0 0
0 0
06 0
100 100 100 100 41.5 100 100 40.2 100 100 38.8 100 100 37.5 100 100 36.2 100 100 34.8 100 100 33.5 100 100 32.2 100 100 30.8 100 100 29.5 100 100 28.2 100 100 27.9 100 100 26.8 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 1.00 100 100 99.6 98.9 98.2 97.6 96.9 96.2 95.6 94.9 94.2 93.6 92.9 92.2 91.6 90.9 90.2 89.6 88.9 88.2 25.5 25.0 24.6 23.9 23.2 22.6 21.9 21.2 20.6 19.9 19.2 18.6 17.9 17.2 16.6 15.9 15.2 14.6 13.9 13.2
%FP CRGP5 T CRGP6 1 CRGP7 CRGP5 CRGP6 1 CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Continued on next page.
Oconee 1 Cycle 27 Rod Index Setpoints 4 Pump Operation, No Inoperable Rods, BOC to EOC ONEI-0400-50 Rev 32 Page 18 of 33 Shutdown Margin Setpoint R
Operational Alarm Setpoint
% FP CRGP 5 CRGP 6 CRGP 7 CRGP 5 CRGP 6 CRGP 7 49 48 47 46 45 44 43 42 41.6 41 40 39.1 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25.7 25 24 23 22 21 20 19 18 17 16 15 14 13 12.8 12 11 10 9
8 7
6 5
4 3
2.8 2
1 0
100 100 100 100 100 100 100 lOO.......
100 100 100 100 99.9-__
99.0 98.0 97.1 96.2 95.2 94.3 93.4 92.5 91.5 90.6 89.7 88.8 87.8 87.5 86.9 85.0 84.1 83.2 82.2 81.3_
80.4 79.5 78.5 77.6 76.7 75.8 75.0 61.5 54.0 46.5 39.0 31.5 24.0 16.5 9.0 1.5 0
0 0
0 43.0 41.5 39.6 37.8 35.9 34.1 32.2 30.4 29.6 28.5 26.6 25.0 24.9 24.0 23.0 22.1 21.2 20.2 19.3 18.4 17.5 16.5_
15.6_
14.7 13.8 12.8 12.5 11.9 11.0 10.0 9.1 8.2 7.2 6.3 5.4 4.5 3.5 2.6
_ 1.7 08 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0~~
0 0
0 0
0
~0 0
0 0
0 0
0 0
0 0
0 0
0 0
-0 0
0 0
0 0
0 0
0 0
0 0
0 0
0-0 0
0 0
0 0
100 100 100 100 100 100 100 100 100 100 100 100 100 1006 100 100 100 100 166 100 100 100 100 100 99.0 97.4 95.8 94.2 92.7 91.1 89.5 88.0 86.4 84.8 83.2 79.5 75.8 75.0 69.0 61.5 54.0 46.5 39.0 31.5 24.0 16.5 9.0 1.5 0
0 0
0 86.7 85.1 83.5 82.0-80.4 78.8 77.2 75.7 75.0 73.2 70.1 67.3 66.9 63.8 60.6 57.5 54.3 51.2 48.1 44.9 41.8 11.7 10.1 8.5 7.0 5.4 3.8 2.2 0.7 0
0 0
0 0
0 0
0 0
00 0
38.6 35.5 32.4 29.2 26.1 25.0 24.0 22.4 20.8 19.2 17.7 16.1 14.5 13.0 11.4 9.8 8.2 4.5 0.8 0
0 0
0 0
0 0
0 0
0 0
-0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
% FP CRGP 51 CRGP 6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin Setpoint E4 Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Oconee 1 Cycle 27 Rod Index Setpoints 3 Pump Operation, No Inoperable Rods, BOC to EOC ONEI-0400-50 Rev 32 Page 19 of 33 Shutdown Margin Setpoint f
Operational Alarm Setpoint
%FP CRGP5 5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 77 76.2 75 74 73 72 71 70 69 68
-- 67.6
-67 E66 65 64 63 62 61 59.3 59 58 57 55 54 53 52 51 50 49 48 47 46 45 44 43 41.6 41 40 39 38 37 36 35 34 33 32 31 30 29 28 100 100 IO00 190 100 100 100 100 100 l0o 100 100 100 100 1.00...
100 100 100 100 100 100 100 100 100 100 100 IO0 0.0....--
100 100 100 100 100 IO00
-99.9 990 98.0 97.1 96.2 95.2 94.3 93.4 92.5 91.5 90.6 89.7 100 100 99.7 98.2 96.8 95.3 93.8 92.3 90.8 89.4 87.9 87.4 86.4 84.9 83.4 82.0 80.5 79.0 77.5 76.0 75.0 74.1 71.1 68.2 65.2 62.2 59.3_
56.3 53.4 50.4 47.4 44.5 41.5 39.6 37.8 35.9_
34.1 32.2 30.4 29.6 28.5 26.6 25.0 24.9 24.0 23.0 22.1 21.2 20.2 19.3 18.4 17.5 16.5 15.6 14.7 27.4 25.0 24.7 23.2 21.8 20.3 18.8 17.3 15.8 14.4 12.9 12.4 11.4 9.9 8.4 7.0 5.5 4.0 2.5 1.0 0
0 0
0
- -0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
00 0
0 0
0 100 100 i60 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100.
100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 IO0 100 100 100 99.6 98.9 98.2-.-
97.6 96.9 96.2 95.6 94.9 94.4 94.2 93.6 92.9 92.2 91.6 90.9 90.2 89.6 88.9 88.2 86.7 85.1 83.5 82.0 80.4 78.8 77.2 75.7 75.0 73.2 70.1 67.3 66.9 63.8 60.6 57.5 54.3 51.2 48.1 44.9 41.8 38.6 35.5 32.4 37.5 36.4 36.1 34.8 33.5 32.1 30.8 29.5 28.1 26.8 25.5 25.0 24.6 23.9 23.2 22.6 21.9 21.2 20.6 19.9 19.4 19.2 18.6 17.9 17.2 16.6 15.9 15.2 14.6 13.9 13.2 11.7 10.1 8.5 7.0 5.4 3.8 2.2 0.7 0
0 0
0 0
0 0
0 0
0 0
0 0
00~
0 0
0 0
0 0
0 100 100 100 100 100 100 100 100
% FP CRGP 5I CRGP6 I CRGP7 CRGP5 I CRGP6 I CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Continued on next page.
Oconee 1 Cycle 27 Rod Index Setpoints 3 Pump Operation, No Inoperable Rods, BOC to EOC ONEI-0400-50 Rev 32 Page 20 of 33 Shutdown Margin Setpoint 11 Operational Alarm Setpoint
%FP CRGP5 CRGP61 CRGP7 CRGP I CRGP6 CRGP7 27 26 25.7 25 24 23 22 21 20 19 18 17 16 15 14 13 88.8 87.8 87.5 86.9 86.0 85.0 84.1 83.2 82.2 81.3 80.4 79.5 78.5 77.6 76.7 13.8 12.8 12.5 11.9 11.0 10.0 9.1 0
0 0
0 0
0 0
100 100 100 99.0 97.4 95.8 94.2 29.2 26.1 25.0 24.0 22.4 20.8 19.2 17.7 16.1 14.5 13.0 11.4 0
0 0
0 0
0 0
0 0
0 0
0 0
8.2 0
7.2 6.3 5.4 0
0 0
92.7 91.1 89.5 88.0 4.5 0
86.4 3.5 0
84.8 9.8 2.6 0
83.2 1.7 0
79.5 8.2 4.5 0.8 75.8 0.8 0
75.8 II-4
-I.
-II 1
12.8 12 11 75.0 0
0 75.0 00
+
I 0
0 69.0 0
0 69.0 61.5 0
0 61.5 0
0 10 9
8 76 4
3 2.8 2
1 0
54.0 0
0 54.0 46.5 0
0 46.5 0
+
-- I~
-II-39.0 31.5 24.0 16.5 0
0 39.0 0
0 0
0 31.5 0
0 24.0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0-0 0
16.5 9-.0 0I 0--
- g.
0[?~
1 0
0 0
0--
0 0
0 0
0 0
0 0
0 0
~~0 0
0
-1 1.
-1
-I1~
I II
-I--
-II-.-
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Oconee 1 Cycle 27 Rod Index Setpoints 4 Pump Operation, 1 Inoperable Rod, BOC to EOC ONEI-0400-50 Rev 32 Page 21 of 33 Shutdown Margin Setpoint Operational Alarm Setpoint
% FP CRGP 5 CRGP 6 CRGP 7 CRGP 5 CRGP 6 CRGP 7 102 100 100 83.A 100 100 83.4 101 100 100 82.5.
100 100 82.5 100 100 100 81.5 100 100 81.5 99 100 100 80.5 100 100 80.5 98 100 10 79.6 __
100 100 79.6 97 100 100 78.6 100 100 78.6 96 100 100 777 100 100 77.7 95 100 100 76.7 100 100 76.7 94 100 100 75.7 100 100 75.7 93 100 100 74.8 100 100 74.8 92 100 100 73.8 100 100 73.8 91 100 100 72.8 100 100 72.9 90 100 100 71.9 100 100 71.9 89 100 100 70.9 100 100 70.9 88 100 100 70.0 100 100 70.0 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64
-- 63_
62
_. 61 60 58 57 56 55 54 53 52 50 49 100 100 100 100 69.0 100 100 69.0 68.0 100 100 68.1 100 100 100 100 100
-100 -
100 100--
100 100 100 100 100-100 100 1.00 100 100 100 100 100 100
-.100 -..
100 100 100 100 -- -
-100 -..
100 100 100 1 00 100 100 100 100 67.1 66.1 100 100 67.1 100 100 66.1 100 1
65.2 11 100 100 100 I
64.2 11 100 100 65.2 64.2 100 100 100 100 100_
100 100 100 100 100 100
-100-100 100 100 100 100
-100
-- 100 100 100 100 100 100 100 100 100 100 100 100 63.2 62.3 61.3 100 100 63.3 100 100 62.3 100 100 61.3 60.3 100 100 60.4 59.4 100 100 59.4 58.4 100 100 58.4 57.5 100 100 57.5 56.5 100 100 56.5 55.5 100 100 55.6 54.6 100 100 54.6 53.6 100 100 53.6 52.7 100 100 52.7 51.7 100 100 51.7 50.7 49.8 48.8-47.8 46.9 45.9 45.0 44.0 43.0 42.1 41.1 40.2 39.2 38.2 37.3 36.3 35.3 34.4 33.4 32.5 31.5 100 100 50.7 100 100 49.8 100 100 48.8 100 100 100 100 100 10--
100 100 100 100 100 100 100 100 100 100
-100 100 I 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 47.8 46.9 45.9 45.0 44.0 43.0 42.1 41.1 40.2 39.2 38.2 37.3 36.3 35.3 34.4 33.4 32.5 0
100 31.5
%FP CRGP5 I CRGP6 CRGP7 CRGP5 I CRGP6 I CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Continued on next page.
Oconee 1 Cycle 27 Rod Index Setpoints 4 Pump Operation, 1 Inoperable Rod, BOC to EOC ONEI-0400-50 Rev 32 Page 22 of 33 I
Shutdown Margin Setpoint Operational Alarm Setpoint
% FP CRGP 5[
CRGP 6 CRGP 7 CRGP 5 CRGP 6 CRGP 7 47 46 45 44.8 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19.8 19 18 17 15 14 13 12 11 10 9
8.7 8
7 6
5 4
3 2.8 2
1 0
100 100 100 100 100 1 *.
100 100 100 100 100-..
.100
-10.0 100.
100 100 1.00-100 100 100
.10 -0 10.0
-100ý 100
.1.00 100 100 10.0 10.0 100 100 100
.100 100 100 97.0 92.8 88.5 84.2 80.0
- 75. 8 75.0 68.0 59.5 51.0 100 100 106 100 99.2 98.2 97.2 96.2 95.2 94.2 93.2 92.2 91.2 90.2 899.2 88.2 87.2 86.2 85.2 84.2 83.2 82.2 81.2 80.2 79.2 78.2 77.2 76.2 75.2 75.0 73.5 71.5 69.5 67.5 65.5 63.5 61.5 53.0 44.5 36.0 27.5 25.0 22.0 17.8 13.5 9.2 5.0 0.8 50 0
0 0
29.5 27.5 25.5 25.0 24.2 23.2 22.2 21.2 20.2 19.2 18.2 17.2 16.2 15.2 14.2 13.2 12.2 11.2 10.2 9.2 8.2 7.2 6.2 5.2 4.2 3.2 2.2 1.2 0.2 0
0 0
0 0
0 0
0 0
00- - - -
0 0----
0 0
0
--0
--0 0 -..
0 0
0 100 100 100 100 -
100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100-100 100 100 100 100 100 100 100 100 97.0 92.8 88.5 84.2 80.0 75.8 75.0 68.0 59.5 51.0 100 100 100 100 99.2 98.2 97.2 96.2 95.2 94.2 93.2 92.2 91.2 90.2 89.2 88.2 87.2 86.2 85.2 84.2 83.2 82.2 81.2 80.2 79.2 78.2 77.2 76.2 75.2 75.0 73.5 71.5 69.5 67.5 65.5 63.5 61.5 53.0 44.5 36.0 27.5 25.0 22.0 17.8 13.5 9.2 5.0 0.8 0
0 0
0--
-29.5 27.5 25.5 25.0_
24.2 23.2 22.2 21.2 20.2 19.2 18.2 17.2 16.2 15.2 14.2 13.2 12.2 11.2 10.2 9.2 8.2 7.2 6.2 5.2 4.2 3.2 2.2 1.2 0.2 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
%FP CRGP5 T CRGP6 I CRGP7 CRGP5 I CRGP6 I CRGP7 77 11 Shutdown Margin Setpoint 11 Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Oconee 1 Cycle 27 Rod Index Setpoints 3 Pump Operation, 1 Inoperable Rod, BOC to EOC ONEI-0400-50 Rev 32 Page 23 of 33 Shutdown Margin Setpoint Operational Alarm Setpoint
%FP CRGP 5 CRGP 6 CRGP 7 CRGP 5 CRGP 6 CRGP 7 77 100 100 85.2 100 100 85.2 76 100 100 83.4 100 100 83.4 75 100 100 81.5 100 100 81.5 74 100 100 79.6 100 100 79.6 73 100 100 77.8 100 100 77.8 72 1010000 759 100 759100 75.9 71 100 100 74.1 100 100 74.1 70 100 100 72.2 100 100 72.2 69 100 100 70.4 100 100 70.4 68 100 100 68.5 100 100 68.5 67 100 100 66.7 100 100 66.7 66 100 100 64.8 100 100 64.8 65 100 100 63.0 100 100 63.0 64 100 100 61.1 100 100 61.1 63 100 100 59.3 100.
100 59.3 62 100 100 57.4 100 100 57.4 61 100 100 55.6 100 100 55.6 60 100 100 53.7 100 100 53.7 59 100 100 51.9
-II 1
4-58 57 56 55 100 100 100 50.0 100 48.2 100 100 IL100 100~
100 100 54 53 52 51 50 49 48 47 46 45 44.8 44 43 42 41 40 39 38 37 35 32 31.
29 --
28 27.2 26 2.4 100 100 100 100 100 100 100 100 100 100 100 100 100
-100 100 100 100 100 100 100 o00- --
100 100 100-100 100 100--
100 100 100 100 100 100 100 100 100 100 100 99.2 98.2 97.2 96.2 95.2 94.2 93.2 92.2 91.2 90.2 89.2
-- 88.2 87.2 86.2 85.2 84.2 83.2 82.2 81.2 80.2 79.2 46.3 44.5 42.6 40.8 38.9 37.1 35.2 33.4 31.5 29.5 27.5 25.5 25.0 24.2 23.2 22.2 21.2 20.2 19.2 18.2 17.2 16.2 15.2 14.2 13.2 12.2 11.2 10.2 9.2 8.2 7.2 6.2 5.2 4.2 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 i6~o...
1060
'100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 1600 100 100 99.2 98.2 97.2 96.2 95.2 94.2 93.2 92.2 91.2 90.2 89.2 86.2 85.2 84.2 83.2 82.2 81.2 80.2 79.2 51.9 50.0 48.2 46.3 44.5 42.6 40.8 38.9 37.1 35.2 33.4 31.5 29.5 27.5 25.5 25.0 24.2 23.2 22.2 21.2 20.2 19.2 18.2 17.2 16.2 15.2 14.2 13.2 12.2 11.2 10.2 9.2 8.2 7.2 6.2 5.2 4.2
%FP CRGP 5 CRGP 6 CRGP 7 CRGP 5 CRGP 6 CRGP 7
_______IF Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Continued on next page.
Oconee 1 Cycle 27 Rod Index Setpoints 3 Pump Operation, 1 Inoperable Rod, BOC to EOC ONEI-0400-50 Rev 32 Page 24 of 33 Shutdown Margin Setpoint Operational Alarm Setpoint
% FP CRGP 5 CRGP 6 CRGP 7 CRGP 5 CRGP 6 CRGP 7 23 22 21 20 19.8 19 18 17 16 15 14
- 13. 3__
12 11 10 9
8.7 8
7 6
5 4
3 2.8 2
1 0
100 1600 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 97.0 92.8 88.5 84.2 80.0 75.8 75.0 68.0 59.5 51.0 78.2 77.2 76.2 75.2 75.0 73.5 71.5 69.5 67.5 65.5 63.5 61.5 53.0 44.5 36.0 27.5 25.0 22.0 17.8 13.5 9.2 5.0 0.8 0
0 0
0 3.2 1.2 0.2 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 100 100 100 100 100 100 100 100 1.00 100 100 100 100 100 100 100 100 97.0 92.8 88.5 84.2 80.0 75.8 75.0 68.0 59.5 51.0 78.2 77.2 76.2 75.2 75.0 73.5 71.5 69.5 67.5 65.5 63.5 61.5 53.0-44.5 36.0 27.5 25.0 22.0 17.8 13.5 9.2 5.0 0.8 0
0 0
0 3.2 2.2 1.2 0.2 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0-0 0
0-0 0
%FP CRGP 5 CRGP6 J CRGP7 CRGP 5 CRGP 6 CRGP 7 7 79 1 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
S I
S Oconee 1 Cycle 27 I
ONEI-040*ev 32 Page 25 of 33 105 100 95 90 85 80 75 70 65 I-60
.0 (D.,,55 o_
50 S45 40 35 30 25 20 15 10 5
0 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5
0 0
10 20 30 40 50 60 70 80 90 100 I Group5I Control Rod Position, % WD
S 105 Oconee I Cycle 27 Control Rod Position Setpointsi 1No Inoperable Rods, 3 Pump FlowI S
ONEI-04*0 Rev 32 Page 26 of 33 100 95 iii III III iii a-LL 0
90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 Unacceptable Operation Restricted Operation 105 100 95 90 85 80 75 70 ii II 65 60 55 50 45 40 35 30 25 20 15 10 I
Acceptable Operation I
5 0
Group 6 ULL!
5 5
25 35 45 55 65 75 85 95 I
0 o
1 0 20 30 40 50 60 70 80 90 100 1
10 10 20 30 40 50 60 70 80 90 100 I I Group 5 I Group 7 Control Rod Position, % WD
Oconee 1 Cycle 27 1
+-H
-]E..
++4 III III III I
I
]
]
I 5
11 fHtf
))]
illl Illl IIII LIIII IIIII Iltll Illil Itlll il II it iiII II II ii IfII It h*LllLt l]ILlll lllLIIl IIlllll iiii1*1 II II li II Ill Ill Ill III IIII II II
.Irm.
T-I Im iii iJJ III III Ill ii!
--r I--I III 411 III Ill
- illIII, IIII IIII IIll IIJ III III III Ill iiJ III IIJ ill iiI}
!t IIii I1[I Illl IlII IILf Ilkl IIII IIII Illl lill Illl IIII Illi lili I
ll
-lI 1TITrl WI I
0--
r II ii il II lEFT Illl IIIJ illI IIII illl 9!![
p IL.LLL ill Jll
!11 mm-
'IF
[
f
Oconee 1 Cycle 27 ONEI-00 Rev 32 105 Page 28 of 33 100 ml5 100 Control Rod Position Setpoints mli1i I9operable Rod, 3 Pum Flow 95 90 90" 85 85 80 80 75 75 70 Unaccep70 Operatio 65 65 EL 60 60 55 55 o.50 50 0M 45 45 a)cetable 40 Operation 40 35 35 30 30 25 25 20 20 15 15 10 10 5
~Group 65 5
15 5
15 25 35 45 55 65 75 85 95 0
0 0
10 20 30 40 50 60 70 80 90 100 F0 10 20 30 40 50 60 70 80 90 100 Group5 1 1Group 7 Control Rod Position, % WD
ONEI-0400-50 Rev 32 Page 29 of 33 Oconee 1 Cycle 27 2.0 Core Operating Limits -- Not Error Adjusted The data provided on the following pages satisfies a licensing commitment to identify specific parameters before instrumentation uncertainties are incorporated.
References provided in section 1 of this COLR identify the sources for the data which follows.
Core Power Level, Quadrant Power Ti Core Outl p
1 1
2C 21 22 23
%FP 3(
it, %
Quadrant Power Tilt Limits Referred to by TS 3.2.3 Steady State 1
)-100 0-30 30-10 5.40 10.00 9.44 ransient 0
0-30 12.00 Maximum 0 - 100 20.00 Variable Low RCS Pressure Protective Limits Referred to by TS 2.1.1 et Pressure Reactor Coolant Outlet Temperature, OF sia 3 RCS Pumps 4 RCS Pumps 300 581.0 578.3 900 590.0 587.3
)00 598.9 596.3 100 607.9 605.2
?00 616.9 614.2 300 625.9 623.2
ONEI-0400-50 Rev 32 Page 30 of 33 Oconee 1 Cycle 27 Axial Power Imbalance Protective Limits Referred to by TS 2.1.1 ot P
o n
se 4 Pumps 3 Pumps
%FP 0.0 80.0 90.0 90.0 100.0 109.4 109.4 100.0 90.0 80.0 0.0 0.0 62.3 77.0 81.7 81.7 77.0 62.3 0.0 RPS Operational
-35.0
-35.0
-14.4 14.4 35.0 35.0
-35.0
-35.0
-14.4 14.4 35.0 35.0
-39.5
-39.5
-39.5
-28.4 28.4 39.5 39.5 39.5
-39.5
-39.5 39.5 39.5
ONEI-0400-50 Rev 32 Page 31 of 33 Oconee 1 Cycle 27 Rod Index Limits Referred to by TS 3.2.1 Operational RI Shutdown Margin RI Insertion Limit RI Withdrawal Insertion Limit No Inop Rod 1 Inop Rod Limit 4 Pumps 3 Pumps
%FP 102 100 90 80 50 15 5
262 260 250 240 200 90 0
220 140 75 0
220 140 75 0
280 230 160 75 280 230 160 75 300 300 300 300 300 300 300 300 300 300 300 77 50 15 5
236 200 90 0
ONEI-0400-50 Rev 32 Page 32 of 33 Oconee 1 Cycle 27 LOCA Limits Core Elevation Feet LOCA LHR kw/ft Limit Versus Burnup Mk-B11 Fuel 0.000 2.506 4.264 6.021 7.779 9.536 12.00 0 GWd/mtU 16.6 17.5 17.6 17.7 17.6 17.5 16.6 0 GWd/mtU 16.7 17.6 17.8 17.8 17.8 17.3 16.4 23 GWd/mtU 16.6 17.5 17.6 17.7 17.6 17.5 16.6 23 GWd/mtU 16.7 17.6 17.8 17.8 17.8 17.3 16.4 40 GWd/mtU 16.6 17.5 17.6 17.7 17.6 17.5 16.6 40 GWd/mtU 16.7 17.6 17.8 17.8 17.8 17.0 16.1 62 GWdImtU 12.2 12.2 12.2 12.2 12.2 12.2 12.2 62 GWd/mtU 12.5 13.2 13.2 13.2 13.2 13.2 12.5 Mk-B-HTP 0.000 2.506 4.264 6.021 7.779 9.536 12.00
ONEI-0400-50 Rev 32 Page 33 of 33 Oconee 1 Cycle 27 fI 4 RCP Operation - Loop Average Temp., TF 3 RCP Operation - Loop Average Temp., TF ATcold, 0F Tavg (Analytical)
Tavg (Analytical) 0.0
<581.0
<581.0 0.1
<581.0
<581.0 0.2
<581.1
<581.0 0.3
<581.1
<58 1.1 0.4
<581.2
<581.1 0.5
<581.2
<581.1 0.6
<581.2
<581.1 0.7
<581.3
<581.2 0.8
<581.3
<581.2 0.9
<581.3
<581.2 1.0
<581.4
<581.2 1.1
<581.4
<581.2 1.2
<581.5
<581.3 1.3
<581.5
<581.3 1.4
<581.5
<581.3 1.5
<581.6
<581.3 1.6
<581.6
<581.4 1.7
<581.6
<581.4 1.8
<581.7
<581.4 1.9
<581.7
<581.4 2.0
<581.8
<581.4 2.1
<581.8
<581.5 2.2
<581.8
<581.5 2.3
<581.9
<581.5 2.4
<581.9
<581.5 2.5
<582.0
<581.6 2.6
<582.0
<581.6 2.7
<582.0
<581.6 2.8
<582.1
<581.6 2.9
<582.1
<581.6 3.0
<582.1
<581.7
- 3. 1
<582.2
<581.7 3.2
<582.2
<581.7 3.3
<582.3
<581.7 3.4
<582.3
<581.7 3.5
<582.3
<581.8 3.6
<582.4
<581.8 3.7
<582.4
<581.8 3.8
<582.4
<581.8 3.9
<582.5
<581.9 4.0
<582.5
<581.9 4.1
<582.6
<581.9 4.2
<582.6
<581.9 4.3
<582.6
<581.9 4.4
<582.7
<582.0 4.5
<582.7
<582.0 4.6
<582.7
<582.0 4.7
<582.8
<582.0 4.8
<582.8
<582.1 4.9
<582.9
<582.1 5.0
<582.9
<582.1