ML093100123
| ML093100123 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry |
| Issue date: | 09/03/2009 |
| From: | Tylinski S AREVA NP |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| 20004-016, L32 090906 800, TS 467 51-9121246-000, Rev 000 | |
| Download: ML093100123 (16) | |
Text
ATTACHMENT 23 Browns Ferry Nuclear Plant (BFN)
Unit 1 Technical Specifications (TS) Change 467 Revision of Technical Specifications to allow utilization of AREVA NP fuel and associated analysis methodologies Safety Limit Minimum Critical Power Ratio Attached is the non-proprietary version of safety limit MCPR analyses results supporting 120% OLTP operation.
A L32 090906 800 20004-016 (07/23/2009)
AREVA AREVA NP Inc.,
an AREVA and Siemens company Engineering Information Record Document No:
51 9121246 -
000 Browns Ferry Unit I Cycle 9 MCPR Safety Limit Analysis (120% OLTP)
Page 1 of 15
20004-016 (0712312009)
ARE VA 51-9121246-000 AREVA NP Inc.,
an AREVA and Siemens company Browns Ferry Unit I Cycle 9 MCPR Safety Limit Analysis (120% OLTP)
Safety related?
EYEs FEIINO Does this document contain assumptions requiring verification?
Does this document contain Customer Required Format?
D YES
-I YES ZNO
~NO Signature Block
- PILP, RILR, PageslSections Name and A/A-CRF, Prepared/Revlewedl Title/Discipline Signature AIA-CRI Date Approved or Comments S.A. Tylinski, Engineer S.
P Thermal-Hydraulics Richland S/r V "i/'/cs DOD. Crockett, Engineer Thermal-Hydraulics Richland c
R
/0) 9 D.W. Pruitt, Manager A/A-CRI Thermal-Hydraulics Richland A.B. Meginnis, Manager A
//2/
II/
Product Licensing
___-31_
/
Note:
P/LP designates Preparer (P), Lead Preparer (LP)
R/LR designates Reviewer (R), Lead Reviewer (LR)
A/A-CRF designates Approver (A), Approver of Customer Requested Format (A-CRF)
NA-CRI designates Approver (A), Approver - Confirming Reviewer Independence (A-CRI)
Record of Revision Revision PageslSectionsl Brief Description I No.
Date Paragraphs Changed Change Authorization 000 Initial issue.
This Is the nonproprietary version of 51-9119738-000.
Page 2
A 20004-016 (07/23/2009)
AR EVA 51-9121246-000 AREVA NP Inc.,
an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP)
Table of Contents 1.0 S um m ary a nd R esults...................................................................................................................
4 Tables 1
Fuel-and Plant-Related Uncertainties MCPR Safety Limit Analyses.......................................
6 2
Results Summary for MCPR Safety Limit Analysis..................................................................
7 3
C o re L o a d ing.................................................................................................................................
7 Figures 1
2 3
4 5
Radial Power Distribution for TLO Limiting Exposure of [
]......................
8 Radial Power Distribution for SLO Limiting Exposure of [
9 Reference Core Loading Pattern........................................................................... 10 Lower Right Quarter Core Layout by Fuel Type....................................................................
12
].............................................................
.. 13 14
].............................................................
15 6
7 Page 3
AREVA NP Inc.,
51-9121246-000 an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP) 1.0 Summary and Results This report presents the Browns Ferry Unit 1 Cycle 9 (BFE1-9) MCPR safety limit analysis results for 120% original licensed thermal power (OLTP) conditions. The MCPR safety limit analysis results presented are applicable in all the equipment out-of-service scenarios and extended operating domains identified in Reference 1.
The MCPR safety limit results presented support 1.07 for two-loop operation (TLO) and 1.10 for single-loop operation (SLO). Therefore, updates to the Browns Ferry Unit 1 Technical Specifications would be required for the BFE1-9 120% OLTP MCPR safety limit.
Reactor system measurement uncertainties are statistically convolved with MCPR calculational uncertainties to determine a MCPR safety limit that ensures that at least 99.9% of the fuel rods in the reactor core would not be expected to experience boiling transition during normal operation or an anticipated operational occurrence. [
] The MCPR safety limit is used in conjunction with transient analysis results to establish the MCPR operating limit.
The MCPR safety limit methodology is described in Reference 2.
The final 120% OLTP core design and step-through, developed by AREVA NP* to meet the operating requirements specified by TVA, was used in the BFE1-9 120% OLTP MCPR safety limit analysis. The BFE1 -9 120% OLTP design supports licensed rated power of 3,952 MWt and operation to licensing end of cycle (EOC) cycle exposure of approximately 19,635 MWd/MTU. The design includes extensions for final feedwater temperature reduction (FFTR) and coastdown.
The BFE1-9 120% OLTP MCPR safety limit analysis used the SPCB critical power correlation additive constants and additive constant uncertainty reported in Reference 3t for ATRIUMTM-10* fuel. [
] The impacts of channel bow were explicitly accounted for in the analysis consistent with the process described in Reference 2. The local power peaking uncertainty is based upon the monitoring computer code as reported in Reference 4. The relationship between assembly flow rate and assembly power was determined for each fuel type using the methodology and assembly flow rate uncertainty reported in Reference 2.
AREVA NP Inc. is an AREVA and Siemens company t
AREVA has submitted an addendum to the NRC for Reference 3. It is Addendum 1 Revision 0 titled, SPCB Additive Constants forATRIUM-IO Fuel. It addresses Condition Report 2007-3653 regarding the CPR test loop power error. Analyses for BFE1-9 120% OLTP incorporate this addendum.
ATRIUM is a trademark of AREVA NP.
Page 4
AREVA NP Inc.,
51-9121246-000 an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP)
The analysis supports:
Fuel-and plant-related uncertainties for BFE1-9 120% OLTP presented in Table 1.
50% of the LPRMs out of service (LPRM bypass model on or off).
Up to 2 TIP machines out of service, or the equivalent number of TIP channels.
2500 EFPH LPRM calibration interval.
No reused channels.
Table 2 presents a summary of the analysis results including the MCPR safety limit and the percentage of rods expected to experience boiling transition for both TLO and SLO. Analyses were performed using the power distributions from each exposure in the design step-through. The safety limit radial power histograms for the limiting TLO and SLO cycle exposures of [
], respectively (i.e., the exposures that results in the highest number of rods expected to experience boiling transition) are presented in Figures 1 and 2. The BFEI-9 120% OLTP core loading and fuel design are presented in Table 3 and Figures 3 through 7.
References
- 1.
51-9107387-000, "Browns Ferry Unit 1 Cycle 9 Calculation Plan," AREVA NP, May 2009.
- 2.
ANF-524(P)(A) Revision 2 and Supplements 1 and 2, ANF Critical Power Methodology for Boiling Water Reactors, Advanced Nuclear Fuels Corporation, November 1990.
- 3.
EMF-2209(P)(A) Revision 2, SPCB Critical Power Correlation, Framatome ANP, September 2003.
- 4.
EMF-2158(P)(A) Revision 0, Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B2, Siemens Power Corporation, October 1999.
- 5.
Letter, H. Donald Curet (AREVA) to H.J. Richings (USNRC), "POWERPLEX Core Monitoring:
Failed or Bypassed Instrumentation and Extended Calibration," HDC:96:012, May 6, 1996.
(38-9043714-000).
- 6.
EMF-2245(P)(A) Revision 0, Application of Siemens Power Corporation's Critical Power Correlations to Co-Resident Fuel, Siemens Power Corporation, August 2000.
Page 5
AREVA NP Inc.,
an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP) 51-9121246-000 Table 1 Fuel-and Plant-Related Uncertainties MCPR Safety Limit Analyses Standard Parameter Deviation Fuel-Related Uncertainties
[
Plant-Related Uncertainties Feedwater flow rate 1.8%
Feedwater temperature 0.8%
Core pressure 0.7%
Total core flow rate TLO 2.5%
SLO 6.0%
- [
I Page 6
AREVA NP Inc.,
an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP) 51-9121246-000 Table 2 Results Summary for MCPR Safety Limit Analysis Percentage of Rods in Boiling SLMCPR Transition TLO - 1.07 0.0687 SLO-1.10 0.0731 Table 3 Core Loading Nuclear Total Serial Fuel Cycle Fuel Number of Number Description Loaded Type Assemblies Prefix GE14 7
4 24 JLX GE14 7
5 12 JLX GE14 7
6 17 JLX GE14 7
9 32 JLX GE14 7
10 12 JLX GE14 7
11 8
JLX GE14 8
14 48 JYE GE14 8
15 96 JYE GE14 8
16 64 JYE GE14 8
17 48 JYE GE14 8
18 71 JYE ATRIUM-10 9
19 192 FAA ATRIUM-10 9
20 40 FAA ATRIUM-10 9
21 100 FAA Page 7
AREVA NP Inc.,
an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP) 51-9121246-000 200 175 150 C:
0 E
z 125 100 75 I
I I
I I
I I
50 25 0
i i
.0
.1
.2
.3
.4
.5
.6
.7
.8
.9 1.0 1.1 Radial Power Peaking 1.2 1.3 1.4 1.5 1.6 Figure 1 Radial Power Distribution for TLO Limiting Exposure of [
I Page 8
AREVA NP Inc.,
an AREVA and Siemens company 51-9121246-000 Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP) 200 175 150 125 100 75
_0 4--
0 E
z 50 25 0
.0
.1
.2
.3
.4
.5
.6
.7
.8
.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 Radial Power Peaking Figure 2 Radial Power Distribution for SLO Limiting Exposure of [
I Page 9
1 3
5 7
9 11 13 15 17 19 21 23 25 27 29 60 JLX621 JLX623 JLX533 JLX643 JYE381 JLX675 JLX725 G
58 JLX625 JYE169 JYE365 JYE245 JYE325 JYE317 JYE333 JYE3090 56 JLX627 JLX478 JYE213 FAA209 FAA233 FAA253 FAA322 FAA177 FAA314 JYE261 54 JLX530 JYE145 JYE341 FAA277 JYE421 FAA117 JYE273 FAA289 JYE133 F'AA2 61
(
52 JYE369 JYE189 FAA273 FAA265 JYE373 FAA305 FAA197 FAA185 JYE293 FAA221 JYE285
(
50 JLX616 JLX541 JYE185 JYE113 FAA001 JYE389 FAA241 JYE409 FAA169 JYE117 FAA201 JYE413 FAA225 48 JLX477 JYE141 FAA281 F'AA065 FAA329 FAA013 JYE349 FAA129 JYE277 FAA045 JYE125 FAA141 JYE101TC 46 JLX615 JYE1 97 JYE345 FAA269 JYE393 FAA093 JYE221 FAA125 JYE301 FAA109 JYE253 FAA157 JYE157 FAA097 44 JLX613 JYE177 FAA213 FAA293 JYE377 FAA245 JYE353 FAA121 JYE397 FAA149 JYE241 FAA029 JYE229 FAA041 JYE153_
42 JLX614 JYE361 FAA237 JYE425 FAA307 JYE405 FAA137 JYE305 FAA133 JYE401 FAA085 JYE149 F'AA021 JLX350 FAA069 C) 40 JLX543 JYE249 FAA249 FAA165 FAA193 FAA173 JYE281 FAA161 JYE201 FAA053 JYE357 FAA077 JYE165 FAA005 JLX291 38 JLX666 JYE329 FAA321 JYE269 FAA189 JYE121 FAA113 JYE257 FAA025 JYE217 FAA073 JYE109 FAA105 JYE181 FAA081 36 JLX448 JYE321 FAA181 FAA285 JYE297 FAA205 JYE129 FAA153 JYE233 FAA057 JYE237 F'AA101 JLX280 FAA297 JYE209
(
34 JLX659 JYE337 FAA313 JYE137 FAA217 JYE417 FAA145 JYE173 FAA049 JLX275 FAA009 JYE225 FAA301 JLX365 FAA061K 32 JLX717 JYE313 JYE265 FAA257 JYE289 FAA229 JYE105 FAA089 JYE161 FAA017 JLX362 FAA037 JYE205 FAA033 JYE193 0) 30 JLX718 JYE316 JYE268 FAA264 JYE292 FAA228 JYE108 FAA100 JYE164 FAA072 JLX276 FAA084 JYE212 FAA064 JYE192 28 JLX663 JYE340 FAA320 JYE140 FAA224 JYE420 FAA144 JYE176 FAA044 JLX361 FAA008 JYE188 FAA300 JLX321 FAA036 26 JYE388 JYE324 FAA180 FAA292 JYE300 FAA204 JYE132 FAA160 JYE236 FAA024 JYE156 FAA108 JLX299 FAA304 JYE208 C
24 JLX544 JYE332 FAA328 JYE272 FAA188 JYE124 FAA048 JYE260 FAA032 JYE220 FAA080 JYE116 FAA104 JYE224 FAA040 22 JLX536 JYE252 FAA256 FAA120 FAA200 FAA172 JYE284 FAA016 JYE240 FAA088 JYE364 FAA076 JYE244 FAA012 JLX279 20 JLX619 JYE360 FAA236 JYE428 FAA308 JYE408 FAA132 JYE308 FAA152 JYE400 FAA056 JYE216 F'AA060 JLX366 FAA020 F
18 JLX620 JYE180 FAA212 FAA280 JYE380 FAA244 JYE356 FAA128 JYE404 FAA136 JYE200 FAA028 JYE232 FAA052 JYE1603 16 JLX618 JYE152 JYE348 FAA268 JYE396 FAA112 JYE228 FAA124 JYE304 FAA164 JYE256 F'AA156 JYE204 FAA092 14 JLX447 JYE144 FAA276 FAA004 FAA332 FAA096 JYE352 FAA140 JYE280 FAA116 JYE128 FAA148 JYE104>
12 JLX617 JLX542 JYE196 JYE112 FAA068 JYE392 FAA248 JYE412 FAA176 JYE120 FAA208 JYE416 FAA232 10 JYE372 JYE184 FAA284 FAA272 JYE376 FAA309 FAA196 FAA192 JYE296 FAA220 JYE288 8
JLX469 JYE148 JYE344 FAA296 JYE424 FAA168 JYE276 FAA288 JYE136 FAA260 C
6 JLX628 JLX479 JYE168 FAA216 FAA240 FAA252 FAA327 FAA184 FAA319 JYE264 4
JL626JYE12 JE36 JYE48 YE32 JY320JYE36 JE31 4
JL626 JYE12 JE36 JYE48 YE32 JY320 JYE36 JEC1 2
JLX622 JLX624 JLX531 JLX673 JYE384 JLX670 JLX728 0I-Figure 3 Reference Loading Pattern
31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 60 JLX729 JLX691 JYE382 JLX688 JLX558 JLX633 JLX635 CD 58 JYE310 JYE334 JYE318 JYE326 JYE246 JYE366 JYE170 JLX631 E0 56 JYE274 FAA315 FAA182 FAA323 FAA25O FAA238 FAA214 JYE202 JLX482 JLX629 54 FAA258 JYE134 FAA286 JYE270 FAA166 JYE422 FAA294 JYE342 JYE146 JLX491 cn 52 JYE286 F'AA218 JYE294 FAA190 FAA194 FAA306 JYE374 FAA270 FAA282 JYE182 JYE370O 50 FAA230 JYE414 FAA206 JYE118 FAA174 JYE410 FAA246 JYE390 FAA066 JYE110 JYE194 JLX547 JLX640 48 JYE102 F'AA146 JYE126 FAA114 JYE282 FAA138 JYE350 FAA094 FAA330 FAA002 FAA274 JYE142 JLX481 46 FA9 JE6 AA5 Y25 A12 JYE302 FAA122 JYE226 FAA110 JYE394 FAA266 JYE346 JYE150 JLX639 44 JYE158 FAA050 JYE230 FAA026 JYE198 FAA134 JYE402 FAA126 JYE354 FAA242 JYE378 FAA278 FAA210 JYE178 JLX637-42 FAA018 JLX355 FAA058 JYE214 FAA054 JYE398 FAA150 JYE306 FAA130 JYE406 FAA312 JYE426 FAA234 JYE358 JLX638 40 JLX286 FAA010 JYE242 FAA074 JYE362 FAA086 JYE238 FAA014 JYE278 FAA170 FAA198 FAA118 FAA254 JYE250 JLX553 38 FAA038 JYE222 FAA102 JYE114 FAA078 JYE218 FAA030 JYE258 FAA046 JYE122 FAA186 JYE262 FAA324 JYE330 JLX545 36 JYE210 FAA302 JLX330 FAA106 JYE154 FAA022 JYE234 FAA158 JYE130 FAA202 JYE298 FAA290 FAA178 JYE322 JYE386 CD 34 FAA034 JLX229 FAA298 JYE186 FAA006 JLX412 FAA042 JYE174 FAA142 JYE418 FAA222 JYE138 FAA316 JYE338 JLX692 32 JYE190 FAA062 JYE206 FAA082 JLX403 FAA070 JYE162 FAA098 JYE1O6 FAA226 JYE290 FAA262 JYE266 JYE314 JLX739 K
30 JYE195 FAA035 JYE207 FAA039 JLX290 FAA019 JYE163 FAA091 JYE107 FAA231 JYE291 FAA259 JYE263 JYE315 JLX740 28 FAA063 JLX287 F'AA303 JYE227 FAA011 JLX343 FAA051 JYE175 FAA147 JYE419 FAA219 JYE139 FAA317 JYE339 JLX702 26 JYE211 FAA299 JLX311 FAA103 JYE239 FAA059 JYE235 FAA155 JYE131 FAA207 JYE299 FAA287 FAA183 JYE323 JYE387 C/)
24 FAA083 JYE183 F'AA107 JYE111 FAA075 JYE219 FAA027 JYE259 FAA115 JYE123 FAA191 JYE271 FAA325 JYE331 JLX701 22 JLX354 FAA007 JYE151 FAA079 JYE359 FAA055 JYE203 FAA163 JYE283 FAA175 FAA195 FAA167 FAA251 JYE251 JLX548 20 FAA071 JLX351 FAA023 JYE215 FAA087 JYE403 FAA135 JYE307 FAA139 JYE407 FAA311 JYE427 FAA239 JYE363 JLX492r 18 JYE155 FAA043 JYE231 FAA031 JYE243 FAA151 JYE399 FAA123 JYE355 FAA247 JYE379 FAA295 FAA215 JYE179 JLX644 3
16 FAA099 JYE159 FAA159 JYE255 FAA015 JYE303 FAA127 JYE223 FAA095 JYE395 FAA271 JYE347 JYE199 JLX642 14 JYE103 FAA143 JYE127 FAA047 JYE279 FAA131 JYE351 FAA111 FAA331 FAA067 FAA283 JYE143 JLX515>
12 FAA227 JYE415 FAA203 JYE119 FAA171 JYE411 FAA243 JYE391 FAA003 JYE115 JYE187 JLX560 JLX641 10 JYE287 FAA223 JYE295 FAA187 FAA199 FAA310 JYE375 FAA267 FAA275 JYE191 JYE371 8
FAA263 JYE135 FAA291 JYE275 FAA119 JYE423 FAA279 JYE343 JYE147 JLX559 C
6 JYE267 FAA318 FAA179 FAA326 FAA255 FAA235 FAA211 JYE167 JLX483 JLX630 4
JYE311 JYE335 JYE319 JYE327 JYE247 JYE367 JYE171 JLX632 2
JLX732 JLX689 JYE383 JLX546 JLX556 JLX634 JLX636 C
0 Figure 3 Reference Loading Pattern (Continued)
AREVA NP Inc.,
an AREVA and Siemens company 51-9121246-000 Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP)
I Fuel Type Description No.
Per Quarter core Cycle Loaded 4
5 6
9 10 11 14 15 16 17 18 19 20 21 GE14-PlODNAB157-NOG 7
GE14-PlODNAB377-16GZ 7
GE14-PlODNAB402-16GZ 7
GE14-PlODNAB419-16GZ 7
GE14-PlODNAB368-15GZ 7
GE14-PlODNAB402-19GZ 7
GE14-PlODNAB406-16GZ 8
GE14-PlODNAB400-17GZ 8
GE14-PlODNAB406-15GZ 8
GE14-PlODNAB417-16GZ 8
GE14-PlODNAB418-16GZ 8
A10-3761B-14GV80-FAA 9
Al0-3831B-12GV80-FAA 9
Al0-4171B-14GV80-FAA 9
Figure 4 Lower Right Quarter Core Layout By Fuel Type 6
3 5
7 3
2 12 24 16 12 18 48 10 25 Page 12
AREVA NP Inc.,
51-9121246-000 an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP)
Page 13
AREVA NP Inc.,
51-9121246-000 an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP)
Page 14
AREVA NP Inc.,
51-9121246-000 an AREVA and Siemens company Browns Ferry Unit 1 Cycle 9 MCPR Safety Limit Analysis (120% OLTP)
Page 15