OFFICE OF THE GENERAL COUNSEL UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON. D.C. 20555-0001 E. Roy Hawkens: Chair Administrative Judge Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, DC 20555 August 24,2007 DOCKETED USNRC December 19,2007 (9:55am)
OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF Anthony J. Baratta Administrative Judge Atomic Safety and Licensing Board U.S. IVuclear Regulatory Commission Washington, DC 20555 Paul B. Abramson Administrative Judge Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, DC 20555 In the Matter of ANIERGEN ENTERGY COMPANY, LLC (Oyster Creek Nuclear Generating Station)
Docket No.50-021 9-LR
Dear Administranva Judges:
In accordance with the "M~!rnorand~!rn and Order (?rehearing Conference Call Summary, Case Management Directives, and Final Scheduling Order)" (Apr. 17, 2007) (unpublished), please find enclosed "NRC Staff Proposed Questions For Evidentiary Hearing" (Bug. 24, 2007).
Pursuant to 10 C.F.R. § 2:1207(a)(3)(i), the enclosed questions are being submitted only to the Board at this time. The Staff understands that, consistent 5 2.1 207(a)(3), the questions will be confidential until propounded by the Board or until issuance of an initial decision, at which time they will be forwarded to the Secretary of the Commission for inclusion in the official record of this proceeding.
Sincerelv.
Counsel for the NRC S%aff
Enclosure:
As stated cc uc! enc!:
D. Wolf,, Esq.
cc wlout encl:
Suzanne Leta Liou Richard Webster, Esq.
Dona!d Si!vermar?, Esq.
/?!ex S. Polnnsky, Esq.
Kathryn M. Sutton, Esq.
J. Bradley Fewell, Esq Office of Commission Appellate Adjudication Office of the Secreta~j
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMNllSSlON BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of 1
AMERGEN ENERGY COIWPANY, LLC
)
Docket No. 50-21 9-LR
)
(Oyster Creek Nuclear Generating Station)
)
NRC STAFF PROPOSED QU EfSTlONS FOR EVlDENTlARY HEARING Pursuant to 10 C.F.R. § 2.1207(a)(3) and "Memorandum and Order (Prehearing Conference Call Summary, Case Management Directives, and Final Scheduling Order)"
(Apr. 17, 2007) (unpublished), the staff of the U.S. Nuclear Regulatory Commission
("Staff') hereby submits proposed questions for the Board to consider asking witnesses in this proceeding.
I _
Questions for Dr. Hausler Reqardinq Stability of the D w e l l Shell A.
Dr. Hausler's Ex~ertise Citizens rely on the expert opinion of Dr. Haulser to support their contention that the frequency of AmerGenl's UT measurements is not adequate to ensure an "adequate safety margin." See LBP-06-22, 64 NRC 229, 240. Citizens, however, have not demonstrated that Dr. Ha~~sler is sufficiently qualified by knowledge, training, skill, or experience to offer opinions on structural stability. See, e.g., Prefiled Rebuttal Written Testimony of Dr. Rudolf H. Hausler Regarding Citizens' Drywell Contention (Aug. 17, 2007)("Citizens1 Rebuttal Testimony") (stating "I will answer [.the Board's] question 12 to the best of my ability in this pre-filed testimony, even though ! am not a struc-tura!
engineer"). The objective of the following proposed questions is to determine what weight, if any, should be given to Dr. Hausler's opinions on structural stability.
- 1.
Do you have any formal training in elastic stability of structures? If so, please describe the extent your training.
- 2.
Do you have any experience with elastic stability of structures? If so, please describe the extent of your experience.
- 3.
Do you have any expertise in calculating stresses in shell structures? If so, please describe the extent of your experience.
- 4.
Have you performed any buckling stability calculations? If so, please describe when, the number of times, for what, and for whom you performed those calculations.
- 5.
Have you preformed any buckling stability calculations for Oyster Creek?
If yes, what did you conclude?
- 6.
Do you have experience in interpreting the results of buckling analyses?
Please describe the extenl of your experience in interpreting the results of buckling analyses.
- 7.
Do you undlerstand the significance of a factor of safety with respect to buckling? If yes, please describe your understanding with respect to the significance of a factor of safety.
- 8.
Do you thinlr a factor of safety slightly less than two would cause the shell to buckle? If so, what is the basis for your conclusion?
B.
Function of,the Drvwell The Staff's positinn is that if buckling of the drywell shell in the sand bed region
- yere to occur It wauld occLlr during refcleling (when the shell is sl~bject t~ the greatest load and when buckling would most likely to occur) and the consequences of such a failure would he minima! because the d w e l l does not perform a cnntainrnent functio~
during refueling outages. See NRC Staff Rebuttal Testimony of Hansraj G. Ashar, Dr. James A. Davis, Dr. Mark Hartzrnan, Timothy O'Hara, and Arthur D. Salomon and Answers to Board Questions (Aug. 14, 2004) ("Staff Rebuttal Testimony"), at A28. The objective of the following p~roposed questions is to determine whether Citizens agree with the Staff that were buckling to occur, it would occur during refueling, i.e., the brief period when the shell does not perform a containment function.
- 1.
For purposes of Citizens' admitted contention, do you agree that the drywell has two functions: (a) containment function under accident conditions and (b) supporting the load of water in the refueling cavity during refueling?
- 2.
For purposes of Citizens' admitted contention, does the drywell perform a containment function during refueling?
- 3.
For purposes of Citizens' admitted contention, do you agree that the only function of the drywell during refueling is to support the load of the water in the refueling cavity?
- 4.
For purposes of Citizens' admitted contention, do you agree that buckling of the drywell shell is only a concern during refueling?
- 5.
Do you know how many days and how often Oyster Creek's drywell shell is subject to refueling loads?
- 6.
In Citizens' Exhibit 38, you cite the importance of risk assessment.
Wouldn't the risk of drywell shell buckling be reduced because of the limited time the drywell shell is exposed to refueling loads?
C.
Safetv Marqb Citizens contend that the frequency of AmerGen's LIT measurements is not adequate to ensure an "adc?quate safety margin." See LBP-06-22, 64 NRC at 240. The nbjedive ~f the fo!!owing proposed questions is to better understand ?:hat Citizens mean by "margin."
- 1.
Is your definition of "margin" the difference between the average measured thicknesses anc UT acceptance criterion? If no, please provide your definition.
- 2.
How does "margin" relate to the concept of "factor of safety" specified in ASME Code Case N-284?
- 3.
Based on your definition of margin, what are the clear, physical consequences for the sand bed region of the drywell shell having zero "margin"?
- 4.
Based only on the data provided by AmerGen, what is the remaining margin for the buckling (refueling condition) criteria for the drywell?
I!.
Questions Reaardiriq Drywell Corrosion A.
Questions for Dr. Hausler Reqardinq Drvwell Corrosion Rate AmerGen asserts that corrosion has been arrested. See Staff Direct Testimony at A22. The Staffs positio~i is that no significant corrosion was evident from AmerGen's inspection results. Id. Citizens assert that corrosion in the sand bed region of the drywell has not been abated. See "Pre-Filed Direct Testimony of Dr. Rudolf H. Hausler" (July 20, 2007) ("Citizens' Direct Testimony") at A1 6. The objective of the following questions is to determine the basis for Citizens' assertion that corrosion is occurring in the sand bed region of the drywell.
- 1.
In Answer 2 of Citizens' Direct Testimony, you estimate 0.049 inch per year as the rate of corrosion of the drywell shell in the sand bed region. Does the UT data since 1992 support that corrosion rate?
- 2.
Doesn't the difference the drywell shell thickness measurements in 1986 and 2006 indicate an average corrosion rate of about 2 mils per year?
- 3.
On page 23 of "Citizens' !?ebutta! Regarding Relicensing of Oyster Creek Nuclear Generating Station" (Aug. 17, 2007) ("Citizens' Rebuttal Position"), Citizens assert that rather than using the observed corrosion rate of 2 mils per year average (which AmerGen contends represents the corrosion rate over 20 years), it would be prudent to use a much higher rate of 10 mils per year. What is the basis for Citizens' assertion that the corrosiori rate will be higher in the future than was observed in the past 20 years?
- 4.
Do Citizens contend that new water introduced onto the interior floor during control rod drive repairs supports the higher corrosion rate? Is yes, why?
- 5.
Do Citizens contend that use of containment spray would cause the higher corrosion rate? If yes, why?
- 6.
Does AmerGen have means to pump water out water introduced into the interior floor?
- 7.
Why would the frequency introduction of water into the interior of the drywell be greater in the fulure than in the last 20 years?
- 8.
On page 23 of Citizens' Rebuttal Position, Citizens assert that AmerGen made critical errors in estimating exterior corrosion, including failing to consider the situation where the plant is forced to fill the refueling cavity in a forced outage. How often does Oyster Creek refuel during a forced outage (i.e., how often would the refueling cavity be fillec! witlh water during a forced outage rather than a planned refueling outage)?
B.
Questions for Dr. Hausler Reqardinq Drvwell Corrosion
!n Memorandun? and Order (Denying ArnerGen's Motion for Summary Disposition) (June 19, 2007) (SD Order) (unpublished) at 9 n.? I, the Board stated that it expected the parties to address the pattern of corrosion in the sand bed region of the drywell and how that pattern of cormsion migM af?ec? the dqviell's susceptibili$j tto buckling. Dr. Hausler provided contour plots, which he asserts illustrate the pattern of corrosion. The Staff's position, however, is that Dr. Hausler's plots overestimate the extent of corrosion and are not consistent with either the observations of the NRC inspector who physically entered the bays or AmerGen's documented UT inspection results. See Staff Rebuttal Testimony at A26, A27. The objective of the following proposed questions is to understand the bases for Dr. Hausler's contour plots.
- 1.
Do you have direct knowledge of the condition of the drywell?
- 2.
Have you validated your plots against AmerGen's video records, color photographs of the inspection, or data sheets? If yes, which one(s)?
- 3.
What is the accuracy of the contour plots presented in your testimony?
- 4.
What is the uncertainty in your contour plots?
- 5.
Have you done any sensitivity analysis to test your assumptions about the physical characteristics of 1:he corrosion of drywell shell in the sand bed region?
- 6.
Have you done any sensitivity analysis on the inputs to your contour plots'?
- 7.
If yes, did your plots change?
- 8.
If yes, how did your plots change?
- 9.
Do you have additional "runs" of this contour plotting software using different increments (e.g., instead of increments of 25 mils, increments of 10 mils)?
- 10.
If yes, what,were the other increments?
- 11.
If yes, what 'was your basis for selecting the 25 mil increment?
- 12.
Did you genlsrate any plots depicting different patterns of degradation that are nst included in ysu.testimony or Citizens' Exhibits?
- 13.
If yes, how was the pattern different?
- 23.
If yes, why didn't you include them as exhibits tc! ynur tesbjm~ny?
- 14.
Are you famiiliar with American Society of Nondestructive Testing (ASNT) qualifications for visual inspectors?
- 15.
If yes, on page 9 of Citizens' Exhibit 39, you refer to an "inspector" as saying, "I could not visually determine which of the thin spots are the thinnest." Was that person trained in accordar~ce with ASNT-SNT-TC-la to make visual observations of this nature?
C.
Questions for Dr. Hausler Reqardinq UT Measurements The accuracy and reliability of ultrasonic testing of the drywell in the sand bed region has been an issue ihroughout this proceeding. The objective of the following questions is to understand Dr. Hausler's qualifications (knowledge, training, skill, or experience) to analyze, interpret, and provide expert testimony on AmerGen's UT measurements, and what eight, if any, should be given to his opinions.
- 1.
Have you ever received training in taking UT measurements? If yes, please describe training.
- 2.
Have you received training in interpreting and analyzing UT measurements? If yes, plcaase describe that training.
- 3.
Do you have any experience in interpreting and analyzing UT measurements? If yes, did that experience include interpreting and analyzing VT data from a drywell shell?
- 4.
Have you read AmerGen's UT procedures?
- 5.
Do you understand the qualifications of a VT-1 inspector? If yes, describe your undprstandir!g of the qualificaticns of a \\JT-1 inspecter.
- 6.
Based upcn a review of AmerGen's UT procedures, and AmerGenls use of qualified inspectors, technicians and supervisors, what is Citizens' estimate, in mils, of the systematic error in the UT measurements?
D.
Internal v. Eixternal UT Measurements Citizens assert that "it is essential to use the external data if the margins are to be calculated in a realistic manner1' and that the external measurements were not taken at the thinnest points. See Citizens' Rebuttal Testimony at A12, A44. The Staff, however, asserts that the use of external measurements only, without regard to the internal measurements, is not representative of the condition of the drywell because the external measurements arle conservatively biased and provide incomplete information about the thickness of the surrounding areas. The objective of the following questions is to probe Citizens' reliance on external measurements.
"1 Is it contradictory to question the validity of AmerGen's external UT measurements yet use them as the basis for your contour plots?
- 2.
Isn't it true that a comparison of the internal UT measurements with the external measurements would provide reliable information about the thickness of surrounding areas?
- 3.
Isn't it true tlhat a comprehensive evaluation of the extent of degradation can only be achieved by using all reliable inspection data instead of relying solely on selected points?
- 4.
In A.46 of Citizens' Rebuttal Testimony you state! "the idea of grinding is to create a flat area at the thickness of the thinnest point, not to make the area thinner."
How would you, in practice, grind an area without making that area of the shell thinner in some way?
E.
Questicns far Dr. Halrsler Reqardi~q Corrosion Mechanism Expert opinions must have an adequate factual basis in order to be considered by the trier of fact. The nbjective of the fol!owing proposed questiens is t~ determine whether certain statements by Dr. Hausler regarding corrosion have an adequate factual
basis.
- 1.
In Citizens' Exhibit 39, you indicate that pit depth can ohly be measured in reference to the original s~lrface and 'therefore physical depth measurements made by GPU are not useful. Is it your position that because of corrosion, none of the original drywell shell surface remai~ns from which a reference could have been established? If yes, what is your basis?
- 2.
On page 4 of Citizens' Exhibit 39, you state, "corrosion could, at least in certain cases, be more severe outside the areas that have been examined by UT." Is this speculation on your pert?
- 3.
On page 6 of Citizens' Exhibit 39, you state that there is a 2.5%
probability that a measurement of less than 0.542 inch may exist and therefore there is "a 2.5% or 0.5% probability that in the event of a.nuclear accident the drywell may not serve as a primary containment and may release radioactive emanations into the environment." Is it your position that a single measurement of 0.542 inch could cause failure of the drywell shell?
- 4.
Do you agree that radioactive emanations may be released into the environment only if the drywell shell is breached? If yes, what would cause the drywell shell to breach?
F.
Questions for AmerGen (Messrs. Polaski, Abramovici, Tamburro, and Dr. Harlow) Reqardinq Drvwell Shell Corrosion In its direct testimony, AmerGen states that the external UT measurements of the thickness of the drywell shell were taken at the thinnest points and that in order to take LIT measurements at those points, It was necessary tc! grind =r f!at surfsce !aye eneugh for the UT probe. See AmerGen's Pre-Filed Direct Testimony Part 3 ("AmerGen Direc%
Testimony") (July 28, 2007:) at A1 8. AmerGen also states that it chose to not to perform
-in
- I V -
UT measurements on a grid because doing so would have required grinding of larger areas and would have unnecessarily reduced the thickness of the drywell. Id. The objective of the following proposed question is to identify the areas were grinding occurred.
- 1.
Which external points were ground to facilitate UT measurements?
Ill.
Questions For Dr. tiauser Reqardincr Epoxv Coatinq In the SD Order the Board stated that one of the remaining litigable issues in this proceed is "the existence vel non of a corrosive environment" in the sand bed region of the drywell. SD Order at 7. The Staffs position is that the likelihood of a corrosive environment existing in the drywell during plant operations is low and that proper implementation of AmerGen's commitments will reduce the potential for such an environment to exist in the future. Citizens assert that corrosion can occur beneath the epoxy coating and that there is a chance that some of the exterior of the drywell shell is not covered by the epoxy. The objective of the following questions is to probe the positions of Citizens and AmerGen on the effectiveness of the epoxy coating in preventing corrosion.
- 1.
Have you calculated the corrosion rate you would expect underneath the epoxy coating if water is eliminated from the externa! sand bed area?
- 2.
If yes, what is the rate? Explain how you performed your calculation.
IV.. Questions for Dr. Hausler Reqardinq Statistics A..
Questions Reoardinq Dr. Hausler's Expertise in Statistics The Staff questions whether Dr. Hausler is qualified by knowledge, :raking, skill, or experience to offer opinions on statistical data analysis. The objective of the following questions is to determine t!e weight to he aff~rded Dr. Haus!er's opinions on statistics!
analysis of UT data results.
- I?
- 1.
Do you have training in statistical analysis? If yes, please describe your training in statistical data a~nalysis.
- 2.
Do you have experience performing statistical analysis? If yes, please describe your experience in performing statistical data analysis.
- 3.
Do you have any training in extreme value statistics? If yes, please describe.
- 4.
Do you havle any experience using extreme value statistics? If yes, please describe when, hovv, and for whom you used extreme value statistics.
B.
Questions Reqardinq Statistics and Requlatorv Requirements Citizens contend that 95% confidence is required to provide reasonable assurance. See, e.g., Citizens' Rebuttal Position at 11. The objective of the following proposed question is to probe the regulatory basis for Citizens' assertion.
- 1.
Does the ASME Code require 95% confidence for analysis of UT thickness measurements? If yes, please state where the ASME Code includes that requirement.
- 2.
Do NRC regulations require 95% confidence for analysis of UT thickness measurements? If yes, please state which NRC regulation requires 95% confidence in IdT measurements.
- 3.
Does AmerGen's calculation of 95% confidence in its analysis of the data constitute an NRC requirernent? If yes, please explain.
- 4.
Do AmerGen procedures require calculatlan of 95% confidence? If yes, which one?
V.
Questions for Dr. tiausler Regarding AmerGen's Commitments & Aginq Manaqement Proqram The Staffs positisri is that based on the 2006 U i measurements and the AmerGen Aging Management Program, as enhanced by commitment to perform UT inspections every other outage (as required by a proposed license condition), provide reasonable assurance that drywell shell integrity (and the intended function of the drywell) will be maintained1 during the period of extended operation. Citizens dispute this position. The objective sf the following proposed questions is to probe Citizens' position on AmerGen's Commitments and Aging Management Program.
- 1.
Are you familiar with the AmerGen's multi-prong Aging Management program as committed in SER, Appendix A?
- 2.
Isn't it true that taking UT measurements every other outage is only part ot AmerGen's aging management program?
- 3.
Isn't it true that taking UT measurements in the sand bed region at shorter intervals would subject-the workers to added radiation exposure?
- 4.
Is your suggested frequency of drywell UT measurements consistent with the as low as reasonable achievable (ALARA) principle? If yes, why?
- 5.
Does the benefit of your suggested UT measurement frequency outweigh the increased dose to workers conducting measurements?
Respecffully submitted,
~ a r y C. Baty Counsel f ~ r NRC Staff Dated at Rockville, Maryland this 24th day of August, 2007