ML073340923
| ML073340923 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 01/31/2007 |
| From: | ASA Analysis & Communication |
| To: | Dynegy Roseton, Entergy Nuclear Indian Point 2, Entergy Nuclear Indian Point 3, Mirant Bowline, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML073340923 (27) | |
Text
Appendix B Physical/Chemical Parameters
APPENDIX B LIST OF TABLES Number Title B-1 Daily freshwater flow (m3/sec/day) estimated for Green Island, New York, 2005 B-2 Long-term (1947-2004) and 2005 monthly mean freshwater flow (m3/sec/day) estimated for Green Island, New York B-3 Monthly mean freshwater flow (m3/sec/day) estimated for Green Island, New York, 1974 to 2005 B-4 Average annual freshwater flow (m3/sec/day) estimated for Green Island, New York, 1947 to 2005 B-5 Poughkeepsies Water Treatment Facility data, mean, minimum, and maximum temperature (°C) for each day of the year, 1951 to 2005 B-6 Average annual water temperature (°C) as measured at Poughkeepsies Water Treatment Facility, 1951 to 2005 B-7 Weighted mean temperature (°C) by region and week from 2005 Long River/Fall Juvenile surveys B-8 Average annual temperature (°C) from Long River/Fall Juvenile surveys, 1974 to 2005 B-9 Mean temperature (°C) by region and week from 2005 Beach Seine Survey B-10 Average annual temperature (°C) from Beach Seine Survey, 1974 to 2005 B-11 Weighted mean salinity (ppt) by region and week from 2005 Long River/Fall Juvenile surveys B-12 Mean salinity (ppt) by region and week from 2005 Beach Seine Survey B-13 Weighted mean dissolved oxygen (mg/L) by region and week from 2005 Long River/Fall Juvenile surveys B-14 Average annual dissolved oxygen (mg/L) from Long River/Fall Juvenile surveys, 1974 to 2005 B-15 Mean dissolved oxygen (mg/L) by region and week from 2005 Beach Seine Survey
B-16 Average annual dissolved oxygen (mg/L) from Beach Seine Survey, 1974 to 2005 B-17 Weighted mean percent oxygen saturation by region and week from 2005 Long River/Fall Juvenile surveys B-18 Mean percent oxygen saturation by region and week from 2005 Beach Seine Survey B-19 Weighted mean conductivity (mS/cm @ 25°C) by region and week from 2005 Long River/Fall Juvenile surveys B-20 Mean conductivity (mS/cm @ 25°C) by region and week from 2005 Beach Seine Survey
Table B-1 Daily Freshwater Flow (m3/sec/day) Estimated for Green Island, New York, 2005 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT1 NOV1 DEC1 DAY OF MONTH 1 480 403 300 1373 787 229 379 138 330 198 467 1677 2 564 365 306 1695 807 191 462 138 330 200 474 1404 3 565 349 299 3339 816 168 326 120 234 164 449 1163 4 696 341 289 2991 706 160 275 127 201 162 377 937 5 770 346 290 1995 607 150 259 118 175 148 380 787 6 640 340 292 1602 569 146 236 126 140 147 363 739 7 563 332 297 1339 536 163 207 105 161 145 412 609 8 524 344 356 1308 476 179 243 123 116 279 435 527 9 496 339 387 1228 482 183 233 108 126 648 393 474 10 471 414 373 1061 456 160 272 98 126 348 882 469 11 436 505 329 934 406 175 247 106 110 216 780 478 12 448 496 322 815 409 205 220 95 131 360 622 459 13 530 435 286 656 385 207 234 127 113 314 514 435 14 1548 372 271 518 302 265 212 119 119 446 368 378 15 1939 397 260 449 291 298 244 127 150 730 468 393 16 1225 461 259 448 322 288 226 141 142 703 723 375 17 900 634 275 418 318 535 203 132 166 392 1215 430 18 614 569 275 392 288 703 219 124 130 326 949 434 19 530 412 275 377 249 710 198 114 131 293 729 418 20 467 372 281 295 224 547 206 116 124 311 644 376 21 459 354 277 342 200 479 175 147 130 275 527 373 22 432 389 321 302 189 402 149 165 129 277 521 367 23 425 362 373 400 206 336 140 147 132 917 584 369 24 450 332 363 967 232 313 132 113 140 792 627 373 25 464 338 325 1434 244 326 141 116 111 897 518 383 26 488 322 335 1188 252 296 121 100 137 1153 481 565 27 476 311 352 944 255 294 139 117 212 1142 478 866 28 459 307 767 1049 251 286 114 117 224 756 530 733 29 440 -- 1939 1024 224 296 130 120 178 694 686 631 30 419 -- 1729 871 198 328 155 146 177 536 1298 1163 31 418 -- 1333 -- 233 -- 154 209 -- 484 -- 1022 1 October through December data are provisional.
Table B-2 Long-Term (1947-2004) and 2005 Monthly Mean Freshwater Flow (m3/sec/day)
Estimated for Green Island, New York 2005 LONG-TERM LONG-TERM LONG-TERM MONTH AVERAGE AVERAGE MINIMUM MAXIMUM JAN 624 387 118 961 FEB 391 395 128 885 MAR 456 618 258 1,077 APR 1,058 866 257 1,749 MAY 385 530 156 1,147 JUN 301 292 101 839 JUL 215 189 87 520 AUG 126 168 48 414 SEP 161 184 58 482 OCT1 466 250 71 853 NOV1 596 364 93 740 DEC1 639 422 173 989 ANNUAL AVERAGE2 451 388 1 October through December data for 2005 are provisional.
2 Weighted by number of days in each month. 2005 average is provisional.
Table B-3 Monthly Mean Freshwater Flow (m3/sec/day) Estimated for Green Island, New York, 1974 to 2005 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 JAN 623 540 417 225 744 571 256 148 321 259 133 439 310 262 268 196 383 FEB 527 548 885 227 400 335 128 851 356 352 552 319 362 201 349 256 703 MAR 587 670 897 987 619 1,077 633 349 613 580 281 581 1,018 605 461 332 994 APR 854 724 1,040 1,092 950 1,009 748 384 897 1,062 761 456 689 981 476 548 894 MAY 650 566 900 421 530 508 274 328 354 1,036 651 232 363 156 357 620 990 JUN 249 367 431 207 282 216 192 169 431 358 275 157 428 175 123 389 250 JUL 333 211 432 162 131 131 144 140 182 127 127 133 250 162 131 92 157 AUG 180 254 414 154 169 149 130 133 124 155 48 104 350 118 139 61 248 SEP 294 482 271 408 175 221 118 233 122 133 58 171 218 341 164 120 159 OCT 256 662 658 853 244 313 158 456 124 71 178 206 336 504 211 254 477 NOV 486 637 507 663 227 465 242 393 196 224 277 423 544 453 565 407 653 DEC 548 532 398 749 303 430 273 319 233 624 447 338 524 437 330 180 687 ANNUAL AVERAGE 466 516 604 512 398 452 275 325 329 415 316 296 449 366 298 288 549 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 Range Average JAN 512 304 550 239 490 736 465 922 426 417 291 168 331 488 624 133-922 408 FEB 496 236 276 337 263 503 516 437 473 473 346 423 279 297 391 128-885 409 MAR 696 408 453 562 514 461 683 873 584 861 413 540 914 651 456 281-1,077 636 APR 655 648 1,749 1,375 257 939 873 652 593 1,069 1,375 693 833 676 1,059 257-1,749 844 MAY 346 501 375 534 158 1,081 643 349 214 898 341 652 621 526 385 156-1,081 518 JUN 144 342 203 233 130 353 180 550 115 573 451 483 413 298 301 115-573 296 JUL 112 254 136 248 94 384 153 243 142 314 195 152 188 259 214 92-432 192 AUG 123 203 140 265 97 191 126 153 84 393 105 112 332 399 126 48-414 181 SEP 136 217 158 190 102 185 127 133 257 228 116 138 257 452 161 58-482 204 OCT 216 286 192 177 361 288 133 169 266 264 115 248 533 222 466 1
71-853 309 NOV 301 531 347 251 693 613 293 190 280 309 163 525 736 350 596 1
163-736 423 DEC 364 438 403 396 328 989 268 187 298 469 220 406 846 759 639 1
180-989 449 ANNUAL AVERAGE 342 364 415 401 291 560 372 405 311 522 344 378 524 448 451 1
275-604 406 1 October through December data for 2005 are provisional.
Table B-4 Average Annual Freshwater Flow (m3/sec/day) Estimated for Green Island, New York, 1947 to 2005 YEAR FLOW YEAR FLOW 1947 457 1976 603 1948 366 1977 514 1949 350 1978 398 1950 398 1979 453 1951 479 1980 275 1952 432 1981 321 1953 395 1982 328 1954 408 1983 415 1955 414 1984 314 1956 393 1985 296 1957 273 1986 451 1958 363 1987 366 1959 401 1988 297 1960 397 1989 287 1961 304 1990 549 1962 299 1991 341 1963 266 1992 364 1964 247 1993 414 1965 219 1994 406 1966 285 1995 291 1967 316 1996 561 1968 353 1997 370 1969 377 1998 405 1970 337 1999 310 1971 420 2000 522 1972 595 2001 342 1973 493 2002 377 1974 465 2003 525 1975 515 2004 449 2005 1
451 1 Data for 2005 are provisional.
Table B-5 Poughkeepsies Water Treatment Facility Data, Mean, Minimum, And Maximum Temperature (°C) for Each Day of the Year, 1951 to 2005 LONG-TERM TEMPERATURE (1951-2004) 2005 ACTUAL MONTH DAY MEAN MINIMUM MAXIMUM TEMPERATURES 1 1 1.5 0.6 4.4 0.7 1 2 1.6 0 4.6 0.8 1 3 1.6 0.6 4.6 0.7 1 4 1.6 0.6 3.4 3.1 1 5 1.5 0 3.4 0.7 1 6 1.3 0 3.3 0.5 1 7 1.4 0 4.1 0.8 1 8 1.2 0 3.4 1 1 9 1.3 0 3.3 1.1 1 10 1.2 0 3.3 1.1 1 11 1.2 0 3.7 1.1 1 12 1.1 0.4 3.4 1.1 1 13 1.1 0 3.5 1.2 1 14 1.1 0 3.2 1.4 1 15 1.1 0 2.8 1.5 1 16 1.1 0.4 2.8 1.5 1 17 1.1 0.5 2.8 1.6 1 18 1.1 0.6 3.3 1.4 1 19 1 0.6 2.8 1 1 20 1 0.5 2.2 1 1 21 1 0 2.4 0.8 1 22 1.1 0.6 2.2 0.9 1 23 1.1 0.6 3.3 0.7 1 24 1 0 3.3 0.7 1 25 1 0 3.7 0.8 1 26 1 0 3.5 1.2 1 27 1 0 3.1 1.1 1 28 1.1 0.5 3 0.8 1 29 1 0.6 2.5 0.5 1 30 1 0 2.5 0.5 1 31 1 0.6 2.8 0.5 2 1 1 0.6 2.4 0.5 2 2 1 0.6 2.7 0.6 2 3 1 0.6 2.2 0.7 2 4 1 0.6 2 0.7 2 5 0.9 0 1.8 0.9 2 6 1 0.5 2 1.2 2 7 1 0.2 2.2 0.7 2 8 1 0 2.2 0.7 2 9 0.9 0.2 2.2 0.6 2 10 1 0.2 3.3 0.6 2 11 1 0 2.6 0.7 2 12 1.1 0.3 2.3 0.5 2 13 1.1 0 2.2 0.5 2 14 1.2 0.3 2.8 0.5 2 15 1.1 0.2 2.8 0.6 2 16 1.1 0 2.8 0.6 2 17 1.2 0.6 4.4 0.7 2 18 1.1 0 2.8 1.1 2 19 1.2 0.6 2.8 0.7 2 20 1.2 0 2.8 0.5 2 21 1.2 0.4 2.8 0.5 2 22 1.3 0 3.9 0.5 2 23 1.3 0 2.8 0.5 2 24 1.3 0 3.9 1.2 2 25 1.3 0.5 2.8 0.5 2 26 1.5 0 3.3 0.5 2 27 1.6 0 4.4 0.5 2 28 1.5 0 5 0.5 2 29 1.8 0.6 4.4 3 1 1.6 0.6 4.4 0.5 3 2 1.6 0.5 4.4 0.5 3 3 1.6 0.5 4.2 0.5 3 4 1.7 0.5 4.9 0.5 3 5 1.7 0.5 4.6 0.5 3 6 1.8 0.6 4.8 0.5 3 7 1.8 0.6 4.7 0.5 3 8 1.8 0 4.9 0.5 3 9 1.9 0.6 4.9 0.6 3 10 2 0.6 5.4 0.5 3 11 2.1 0.6 5.3 0.5 3 12 2.1 0.5 5.1 0.8 3 13 2.2 0.5 5.3 0.9 3 14 2.3 0.6 5.6 0.8 3 15 2.5 0.6 5.8 0.8
Table B-5 (Continued)
LONG-TERM TEMPERATURE (1951-2004) 2005 ACTUAL MONTH DAY MEAN MINIMUM MAXIMUM TEMPERATURES 3 16 2.5 0.6 5.6 1.6 3 17 2.6 0.6 5.7 1.4 3 18 2.7 0.5 5.9 1.6 3 19 2.7 0.6 7.7 1.9 3 20 2.9 0.6 7.5 2.7 3 21 3.1 0.6 7.3 2.3 3 22 3.2 0.6 7.2 2.5 3 23 3.3 0.6 7.1 2.9 3 24 3.5 0.6 7.1 2.9 3 25 3.7 0.6 6.4 3.2 3 26 3.8 0.6 6.5 3.7 3 27 4.1 1.1 6.9 3.9 3 28 4.3 1.1 6.8 4 3 29 4.6 1.1 7.5 5.9 3 30 4.8 1.1 8.3 4.6 3 31 5.1 1.1 8.4 4.7 4 1 5.4 1.7 9.4 4.5 4 2 5.4 2.2 9.1 5.1 4 3 5.7 2.8 10.8 6.3 4 4 5.7 2.8 9.2 7.8 4 5 5.9 2.8 8.8 8.1 4 6 6.1 3.3 9.3 6.3 4 7 6.3 2.8 9.5 6.5 4 8 6.5 2.8 9.4 7.2 4 9 6.4 2.8 9.2 7.8 4 10 6.6 2.8 10.2 8.1 4 11 6.8 2.8 11.2 8.5 4 12 7 2.8 11.4 8.7 4 13 7.2 2.8 11.4 9.2 4 14 7.4 2.8 11.4 9.4 4 15 7.6 2.8 11.5 9.2 4 16 7.8 3.3 11.8 9.4 4 17 7.9 3.9 11.7 9.7 4 18 8.1 5.6 13.1 11.5 4 19 8.5 5.6 13.9 10.9 4 20 8.6 6.1 12.2 11.4 4 21 9 6.1 12.2 11.4 4 22 9.2 6.7 12.8 11.4 4 23 9.6 6.7 14 11.7 4 24 9.7 6.7 14.1 11.8 4 25 9.7 6.7 13.9 12.1 4 26 10 6.7 13.6 12.4 4 27 10.2 7.2 13.3 12.6 4 28 10.5 7.8 13.3 12.6 4 29 10.8 8.3 13.9 12.6 4 30 11.1 8.9 13.9 12.7 5 1 11.2 8.9 14.4 12.7 5 2 11.4 8.9 14.4 12.7 5 3 11.7 8.9 14.4 12.5 5 4 12 8.9 15 12.3 5 5 12.1 8.9 15 12.2 5 6 12.3 8.9 15 12.2 5 7 12.6 8.9 15.2 12.3 5 8 12.7 8.9 15.4 12.2 5 9 12.8 8.9 15.6 12.3 5 10 13 8.9 16.1 12.6 5 11 13.2 9.4 16.2 12.8 5 12 13.3 9.4 16.5 13.1 5 13 13.5 10 16.7 13.2 5 14 13.7 10.6 16.7 13.5 5 15 13.9 11.1 16.8 13.8 5 16 14.1 11.1 17.6 13.8 5 17 14.4 11.7 17.7 14.3 5 18 14.6 11.7 17.9 14.6 5 19 14.9 11.7 18.3 14.9 5 20 15.1 12.2 18.6 16.3 5 21 15.4 12.7 19.3 17.5 5 22 15.5 12.5 18.5 15.4 5 23 15.6 12.4 18.9 15.4 5 24 15.9 12.8 20.1 15.5 5 25 16.1 12.8 20.1 15.2 5 26 16.4 12.2 20.8 16.4 5 27 16.6 12.2 20.6 15.9 5 28 16.9 12.2 20.8 15.7 5 29 17 12.8 20.7 16
Table B-5 (Continued)
LONG-TERM TEMPERATURE (1951-2004) 2005 ACTUAL MONTH DAY MEAN MINIMUM MAXIMUM TEMPERATURES 5 30 17 12.8 21.5 16.1 5 31 17.1 13.3 21.3 17.5 6 1 17.7 13.3 22 16.7 6 2 18 13.3 22.2 17 6 3 18.1 14.4 22.1 17.3 6 4 18.3 13.9 22.5 17.6 6 5 18.4 15 22.2 18 6 6 18.5 15.6 22.4 18.3 6 7 18.7 15 22.4 18.7 6 8 19 16.1 22.5 19.3 6 9 19.2 16.3 23 19.6 6 10 19.5 17.2 23.2 20.2 6 11 19.7 17.2 23.4 20.5 6 12 19.8 17.2 23.3 20.9 6 13 19.9 17.8 23.4 21.3 6 14 20.1 17.5 23.3 21.8 6 15 20.2 17.2 23.5 22.1 6 16 20.4 17.8 23.8 22.1 6 17 20.5 17.8 23.8 22.4 6 18 20.8 17.8 24.2 22.8 6 19 20.8 17.8 24.1 23 6 20 21 17.8 24 23.2 6 21 21.2 17.8 24.3 23.5 6 22 21.4 17.2 24.3 23.7 6 23 21.5 17.2 24.1 23.6 6 24 21.7 17.8 24.1 23.8 6 25 21.8 17.8 24.2 24 6 26 22 17.8 24.5 24.4 6 27 22.1 17.8 24.4 24.7 6 28 22.3 17.8 24.7 24.9 6 29 22.5 17.8 25 25 6 30 22.5 17.8 25 25.1 7 1 22.7 18.9 25.4 25.5 7 2 22.8 18.9 25.1 25.5 7 3 22.9 19.4 25 25.5 7 4 22.9 19.4 25 25.5 7 5 23.2 20 25.7 25.5 7 6 23.3 20 25.6 25.5 7 7 23.4 20 26.3 25.5 7 8 23.5 20 26.1 25.5 7 9 23.6 20 26.2 25.5 7 10 23.6 20.6 26 25.4 7 11 23.7 20.6 26 25.5 7 12 23.9 21.1 26.4 25.5 7 13 24.1 21.7 26.7 25.5 7 14 24.1 21.7 26.7 25.5 7 15 24.3 21.7 26.7 25.6 7 16 24.4 22.2 26.7 25.6 7 17 24.4 22.2 26.6 25.7 7 18 24.4 22.2 26.3 26 7 19 24.6 22.2 26.6 26.1 7 20 24.7 22.2 26.8 26.3 7 21 24.7 22.8 26.6 26.6 7 22 24.9 22.2 27 26.6 7 23 24.9 22.2 27 26.6 7 24 24.9 22.8 26.8 26.6 7 25 24.9 22.8 26.7 26.6 7 26 24.9 22.8 26.8 26.8 7 27 25.1 22.8 27.2 27.1 7 28 25.1 22.8 27.2 27 7 29 25.2 22.8 27.1 27 7 30 25.2 23.3 27.1 27 7 31 25.2 23 27.1 27.2 8 1 25.2 22.8 26.7 27 8 2 25.2 22.8 27.4 27.2 8 3 25.3 22.8 27.3 26.8 8 4 25.3 22.8 27.4 27.4 8 5 25.5 23.3 27.2 27.7 8 6 25.4 23.3 27.2 27.6 8 7 25.3 23.2 27.4 27.6 8 8 25.3 23.3 27.4 27.5 8 9 25.3 23.3 27.8 27.6 8 10 25.3 23.3 27.8 27.5 8 11 25.3 22.8 27.8 27.7 8 12 25.3 22.8 28.1 27.7
Table B-5 (Continued)
LONG-TERM TEMPERATURE (1951-2004) 2005 ACTUAL MONTH DAY MEAN MINIMUM MAXIMUM TEMPERATURES 8 13 25.2 22.2 28 27.7 8 14 25.1 22.2 28.4 27.8 8 15 25.1 22.2 28.4 27.2 8 16 25 22.2 28.4 27.7 8 17 25 22.2 28.1 27.6 8 18 24.9 22.8 28 27.4 8 19 25 22.2 27.7 27.3 8 20 25 22.8 27.6 27.1 8 21 24.9 22.2 27.5 27.1 8 22 24.8 22.2 27.1 27 8 23 24.7 22.5 26.9 26.6 8 24 24.6 22.2 26.7 26.6 8 25 24.5 21.7 26.2 26.4 8 26 24.5 21.7 26.2 26.3 8 27 24.6 22.2 26.3 26.3 8 28 24.5 22.2 26.3 26.2 8 29 24.3 22.2 26.7 26.1 8 30 24.3 22.2 26.1 26.2 8 31 24.2 22.2 26.1 26.3 9 1 24.2 22.2 26.1 26.1 9 2 24.1 22.2 26.7 25.9 9 3 24 22.2 26.1 25.8 9 4 24 22.2 25.6 25.6 9 5 23.9 21.7 25.6 25.5 9 6 23.8 22.2 25.6 25.5 9 7 23.6 21.6 25.6 25.5 9 8 23.5 21.7 25.6 25.5 9 9 23.5 21.7 25.6 25.5 9 10 23.4 21.1 25.6 25.2 9 11 23.3 21.1 25.6 25 9 12 23.1 21.1 25.6 24.9 9 13 23 20 25.6 25 9 14 22.8 18.9 25 25.1 9 15 22.6 17.8 25 25.1 9 16 22.5 17.2 25 25.1 9 17 22.3 17.2 25 25.1 9 18 22.1 16.7 25 24.9 9 19 22 16.7 23.9 24.9 9 20 21.7 17.2 23.9 24.9 9 21 21.4 16.7 23.3 24.7 9 22 21.3 16.1 23.3 24.6 9 23 21 16.1 23.1 24.4 9 24 20.9 15.6 23.1 24.2 9 25 20.8 15.6 23 23.9 9 26 20.7 15.6 22.8 23.8 9 27 20.4 16.1 22.3 23.5 9 28 20.2 15.6 22.2 23.3 9 29 19.9 15.6 22.2 23.1 9 30 19.8 15.6 22.2 22.6 10 1 19.6 16.1 22.2 22.5 10 2 19.4 15.6 22.2 22.2 10 3 19.3 15.6 22.2 22 10 4 19 15.6 21.7 22.1 10 5 18.7 15 21.1 22.1 10 6 18.5 15 21.1 22 10 7 18.5 15 21.1 22.1 10 8 18.2 14.4 21.1 21.6 10 9 17.9 14.4 21.1 20.2 10 10 17.8 14.4 21.1 18.7 10 11 17.7 13.9 21.1 17.7 10 12 17.3 13.3 21.1 17.3 10 13 17.1 13.3 20 16.8 10 14 16.9 12.8 21.1 16.9 10 15 16.8 12.2 20 15.7 10 16 16.6 12.2 20 15.1 10 17 16.4 12.8 20 15 10 18 16.2 12.2 20 14.8 10 19 15.9 11.7 20 14.6 10 20 15.6 10.6 19.4 14.5 10 21 15.3 10.6 18.9 14.4 10 22 15.1 10 18.9 13.9 10 23 14.9 10 18.9 13.6 10 24 14.7 10 18.3 13.3 10 25 14.5 10 18.3 12.7 10 26 14.3 10 17.8 11.5
Table B-5 (Continued)
LONG-TERM TEMPERATURE (1951-2004) 2005 ACTUAL MONTH DAY MEAN MINIMUM MAXIMUM TEMPERATURES 10 27 13.9 9.4 17.8 11.3 10 28 13.9 8.9 17.8 9.9 10 29 13.6 8.3 17.8 9.6 10 30 13.4 7.8 16.7 9 10 31 13.2 7.2 16.7 9.1 11 1 13.1 7.2 16.7 9 11 2 12.9 7.2 16.1 8.9 11 3 12.6 7.2 16.1 9.1 11 4 12.4 7.2 15.6 9 11 5 12.2 7.2 15.6 9.3 11 6 11.9 6.7 15.6 9.5 11 7 11.7 6.1 15 9.4 11 8 11.4 6.1 15 9.7 11 9 11.2 5.6 15 9.7 11 10 10.8 5 14.4 10 11 11 10.4 5 13.9 10.1 11 12 10.3 5 13.3 9.9 11 13 10.1 5 13.3 9.6 11 14 9.9 5 13.3 9.8 11 15 9.8 5 12.8 9.7 11 16 9.5 5 12.8 10.1 11 17 9.2 5 12.8 10.1 11 18 9 5 12.8 9.9 11 19 8.8 5 12.2 10.2 11 20 8.5 4.9 11.1 8.7 11 21 8.3 3.9 11.1 8.1 11 22 8.1 3.9 11.1 8.2 11 23 8 3.9 11.1 7.2 11 24 7.7 3.9 10.6 6.7 11 25 7.4 3.9 10.6 6.1 11 26 7.3 3.3 10.2 5.7 11 27 7 3.3 10.4 5.4 11 28 6.9 3.3 10.5 5.3 11 29 6.7 3.3 10.3 5.4 11 30 6.5 2.8 10.3 5.3 12 1 6.2 2.2 9.4 5.2 12 2 6 3 8.9 5.6 12 3 5.8 2.2 9.3 6 12 4 5.5 1.3 8.3 6 12 5 5.3 2.8 9.6 5.9 12 6 5.3 2.6 9.6 6 12 7 5.3 2 9.8 8.1 12 8 4.9 2 8.2 6.1 12 9 4.6 1.7 8.1 5.3 12 10 4.4 1.1 8.8 4.4 12 11 4.2 1.1 8.8 4.3 12 12 3.9 0.6 8.8 3.7 12 13 3.9 0.6 8.8 2.9 12 14 3.8 0.6 8.6 2.5 12 15 3.4 0.6 7.1 2.1 12 16 3.3 0.6 6.9 1.8 12 17 3.2 0.6 8 1.3 12 18 3 0.6 7.9 1.1 12 19 2.7 0.6 7.6 0.6 12 20 2.8 0.6 7.6 0.5 12 21 2.7 0.6 7.5 0.5 12 22 2.4 0.6 6.5 0.5 12 23 2.2 0.6 6.1 5.2 12 24 2.2 0.6 7.3 0.8 12 25 2.1 0.6 5.6 0.5 12 26 1.9 0 6.1 0.6 12 27 1.9 0 6.1 0.5 12 28 2 0 6.1 0.6 12 29 1.8 0 6.1 0.7 12 30 1.8 0.6 6.1 0.8 12 31 1.8 0 5 1.2
Table B-6 Average Annual Water Temperature (°C) as Measured at Poughkeepsies Water Treatment Facility, 1951 to 2005 YEAR TEMPERATURE YEAR TEMPERATURE 1951 11.66 1978 12.27 1952 12.25 1979 12.49 1953 12.87 1980 12.72 1954 11.92 1981 12.63 1955 12.40 1982 12.48 1956 11.92 1983 13.01 1957 13.03 1984 13.04 1958 12.18 1985 13.05 1959 12.90 1986 12.69 1960 11.29 1987 12.66 1961 12.17 1988 12.57 1962 11.63 1989 12.09 1963 11.82 1990 12.77 1964 12.99 1991 13.67 1965 12.51 1992 12.10 1966 12.75 1993 12.47 1967 12.05 1994 12.39 1968 13.10 1995 12.48 1969 12.59 1996 12.19 1970 12.79 1997 12.42 1971 12.31 1998 13.96 1972 11.35 1999 13.22 1973 12.73 2000 12.25 1974 11.61 2001 13.41 1975 12.37 2002 13.17 1976 11.43 2003 12.46 1977 11.97 2004 13.07 2005 12.94
Table B-7 Weighted Mean Temperature (°C) by Region and Week from 2005 Long River/Fall Juvenile Survey WEEK REGIONS BEGINNING MONDAY BT YK TZ CH IP WP CW PK HP KG SG CS AL 14MAR05 2.9 3.0 3.0 3.0 2.0 1.5 1.4......
21MAR05 4.5 4.2 3.7 3.7 3.4 2.8 2.3......
28MAR05 5.0 5.1 4.6 4.8 5.0 5.0 4.6......
04APR05 5.9 5.9 6.8 6.3 6.4 7.0 7.2 6.3 6.0 6.0 5.9 6.3 6.5 11APR05 8.7 9.1 9.0 9.2 8.3 7.9 7.9 8.8 9.0 9.0 8.5 8.5 8.4 18APR05 9.8 10.7 11.8 10.4 10.6 10.3 10.8 10.8 11.8 12.2 12.0 12.3 12.6 25APR05 11.2 11.9 12.1 12.4 12.1 11.6 11.6 12.1 12.2 11.8 12.2 12.1 12.4 02MAY05 10.4 12.1 12.6 12.9 12.7 12.4 12.6 12.4 12.2 11.3 10.4 10.2 10.4 09MAY05 12.2 13.3 14.1 15.1 15.2 13.7 13.7 12.7 12.2 12.3 11.7 11.3 10.9 16MAY05 14.1 15.4 16.0 15.5 15.5 14.5 14.7 14.6 14.9 15.4 15.2 15.7 16.2 23MAY05 14.0 14.2 14.9 15.8 15.7 15.3 15.2 14.9 15.6 15.9 16.1 16.6 16.5 30MAY05 16.1 16.7 18.1 18.5 18.0 16.2 16.5 16.8 17.1 17.2 17.6 17.7 17.4 06JUN05 18.9 20.2 21.1 21.7 21.4 19.3 19.0 19.1 19.9 20.0 20.6 21.0 21.5 13JUN05 19.1 21.8 23.0 22.4 22.7 21.8 22.0 22.2 22.4 23.9 24.9 25.5 26.1 20JUN05 19.9 21.1 22.3 22.7 23.0 22.8 22.4 23.0 24.0 23.6 23.9 23.3 21.6 27JUN05 21.8 23.5 25.1 25.9 25.1 24.4 24.9 25.2 25.0 25.2 24.7 24.3 24.7 04JUL05 22.8 23.5 24.3 25.1 25.8 25.2 25.4 25.6 25.6 25.5 25.3 25.5 24.6 11JUL05 22.9 24.0 24.8 25.9 26.1 25.4 25.7 26.5.....
18JUL05 24.3 25.1 26.3 27.1 27.4 24.6 26.6 27.0 26.2 26.8 26.3 26.2 26.2 25JUL05 25.7 27.4 28.1 28.9 29.1 26.7 27.8 28.1.....
01AUG05 24.9 26.1 27.5 28.7 27.9 28.1 27.9 28.0 27.4 27.5 27.2 27.3 27.2 08AUG05 25.3 26.8 27.7 29.4 29.6 28.7 29.0 29.1.....
15AUG05 25.0 26.3 27.5 28.4 29.4 29.0 28.8 28.9 28.1 28.1 28.1 28.1 28.2 22AUG05 25.9 26.4 27.0 28.5 28.4 27.5 27.5 27.9.....
29AUG05 24.5 25.1 26.1 27.7 27.9 27.4 27.4 27.6 26.6 25.9 25.1 25.2 24.9 05SEP05 24.2 25.1 25.6 26.3 26.9 26.2 26.2 25.9.....
12SEP05 24.2 24.8 25.8 26.9 27.0 26.7 26.6 26.9 25.8 23.9 23.9 24.1 24.0 19SEP05 24.5 25.0 25.2 25.9 26.7 25.8 25.8 25.4.....
26SEP05 21.7 22.0 22.4 23.9 24.7 24.0 23.6 23.7 22.7 22.1 21.6 21.5 21.6 03OCT05 21.5 21.8 22.1 22.9 23.4 23.0 22.7 22.4.....
10OCT05 20.5 20.9 21.1 20.3 19.9 19.0 18.7 17.8 16.7 16.5 16.4 15.7 15.6 24OCT05 15.7 15.1 15.4 14.7 14.0 13.3 12.7 11.7 10.6 9.4 9.1 8.9 8.6 07NOV05 13.4 12.8 11.7 10.9 10.2 9.8 9.9 9.6 9.6 9.7 10.0 10.5 10.8 28NOV05 9.8 9.1 8.7 8.7 8.3 6.7 6.7 5.8 4.9 5.8 5.7 6.3 6.9 Note: Dots (.) indicate no sampling.
Table B-8 Average Annual Temperature (°C) from Long River/Fall Juvenile Surveys, 1974 to 2005 YEAR TEMPERATURE 1974 21.54 1975 22.10 1976 20.04 1977 20.79 1978 20.16 1979 21.53 1980 21.23 1981 20.96 1982 19.16 1983 19.14 1984 19.22 1985 21.69 1986 21.28 1987 21.41 1988 21.80 1989 20.65 1990 20.97 1991 23.59 1992 21.06 1993 21.01 1994 21.93 1995 21.78 1996 20.18 1997 20.96 1998 22.26 1999 23.17 2000 20.43 2001 21.43 2002 22.07 2003 21.09 2004 21.94 2005 22.14
Table B-9 Mean Temperature (°C) by Region and Week from 2005 Beach Seine Survey WEEK REGIONS BEGINNING MONDAY YK TZ CH IP WP CW PK HP KG SG CS AL 13JUN05 23.2 23.6 24.1 23.7 22.7 23.8 23.5 23.3 24.4 25.1 26.5 26.2 27JUN05 25.4 25.4 24.5 25.7 25.2 25.1 24.8 23.9 25.4 25.3 25.2 25.3 11JUL05 26.2 27.2 26.5 28.0 26.2 26.8 27.5 26.1 25.2 25.9 25.8 24.2 25JUL05 26.1 27.4 28.4 29.1 26.4 28.8 26.6 24.3 24.0 25.1 27.7 26.5 08AUG05 27.1 28.3 30.0 30.2 28.6 29.3 29.4 27.5 26.5 27.6 28.6 27.3 22AUG05 26.9 26.6 25.5 27.7 26.8 26.4 27.1 25.2 25.5 26.8 25.5 24.9 05SEP05 25.7 24.9 26.4 27.5 26.7 27.2 25.9 24.4 24.3 25.4 25.9 23.5 19SEP05 25.1 25.0 25.7 27.1 26.1 26.0 25.1 23.7 23.6 25.0 24.8 23.1 03OCT05 21.2 21.1 22.2 23.7 23.4 23.0 22.1 20.4 19.6 21.0 21.0 19.3 17OCT05 14.7 15.1 16.2 17.6 15.0 15.4 15.0 14.2 14.2 14.6 14.0 13.5
Table B-10 Average Annual Temperature (°C) from Beach Seine Surveys, 1974 to 2005 YEAR TEMPERATURE 1974 21.34 1975 21.59 1976 22.21 1977 22.85 1978 23.71 1979 23.05 1980 24.29 1981 21.91 1982 22.73 1983 24.53 1984 23.17 1985 23.38 1986 22.02 1987 23.03 1988 23.16 1989 24.15 1990 24.34 1991 23.63 1992 22.07 1993 23.48 1994 22.39 1995 23.85 1996 24.42 1997 22.41 1998 24.20 1999 23.42 2000 22.32 2001 24.89 2002 24.52 2003 23.69 2004 22.60 2005 25.69
Table B-11 Weighted Mean Salinity (ppt) by Region and Week from 2005 Long River/Fall Juvenile Survey WEEK REGIONS BEGINNING MONDAY BT YK TZ CH IP WP CW PK HP KG SG CS AL 14MAR05 13.9 6.0 3.2 2.7 0.2 0.2 0.2......
21MAR05 18.0 9.4 7.8 6.7 5.4 3.1 0.8......
28MAR05 7.4 3.6 1.3 0.2 0.2 0.2 0.2......
04APR05 6.6 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 11APR05 12.3 4.6 1.9 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 18APR05 14.6 8.4 4.2 4.6 2.9 0.8 0.1 0.1 0.1 0.1 0.1 0.1 0.1 25APR05 10.6 4.5 2.3 0.8 0.4 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 02MAY05 15.5 5.6 0.5 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 09MAY05 10.7 5.3 2.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 16MAY05 12.3 5.3 5.0 2.8 2.4 0.6 0.1 0.1 0.1 0.1 0.1 0.1 0.1 23MAY05 14.7 11.0 7.4 5.2 3.5 2.4 1.4 0.1 0.1 0.1 0.1 0.1 0.1 30MAY05 19.0 13.4 7.0 4.5 2.3 0.7 0.3 0.1 0.1 0.1 0.1 0.2 0.2 06JUN05 16.6 10.8 7.5 4.7 2.5 0.5 0.3 0.1 0.1 0.1 0.1 0.1 0.1 13JUN05 20.1 13.4 8.3 6.5 3.7 1.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 20JUN05 17.4 12.7 7.4 5.3 2.8 0.4 0.3 0.1 0.2 0.2 0.2 0.1 0.1 27JUN05 18.4 10.0 4.2 2.2 1.1 0.4 0.1 0.1 0.2 0.1 0.1 0.1 0.1 04JUL05 15.3 11.3 7.4 4.1 2.0 0.4 0.2 0.2 0.1 0.1 0.1 0.1 0.1 11JUL05 16.9 10.3 6.7 4.6 2.3 0.6 0.2 0.1.....
18JUL05 19.2 13.5 7.8 5.3 3.4 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 25JUL05 18.7 9.4 5.2 4.2 2.0 0.5 0.3 0.1.....
01AUG05 19.6 15.1 9.9 6.0 4.3 1.4 0.4 0.1 0.1 0.1 0.1 0.1 0.1 08AUG05 20.6 14.1 10.0 6.7 4.0 1.4 0.5 0.1.....
15AUG05 23.1 17.2 11.0 7.9 4.7 3.1 2.0 0.3 0.1 0.1 0.1 0.1 0.1 22AUG05 16.8 11.2 8.1 6.1 4.5 1.8 1.0 0.3.....
29AUG05 20.8 14.8 9.1 6.7 4.6 3.5 2.2 0.4 0.1 0.2 0.2 0.2 0.1 05SEP05 18.4 11.9 8.2 5.9 4.7 2.2 0.8 0.1.....
12SEP05 23.0 17.8 11.1 7.6 5.2 3.3 2.3 0.5 0.2 0.2 0.2 0.2 0.1 19SEP05 15.9 11.0 7.8 6.2 5.4 2.9 1.4 0.3.....
26SEP05 22.8 16.6 11.6 6.8 4.9 3.0 1.9 0.4 0.2 0.1 0.1 0.1 0.1 03OCT05 19.0 13.6 9.5 6.9 5.5 3.2 1.2 0.2.....
10OCT05 15.1 6.6 3.6 1.0 0.4 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 24OCT05 10.5 5.8 4.2 1.9 0.5 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 07NOV05 14.7 8.3 3.6 0.3 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 28NOV05 16.8 10.8 5.3 3.3 1.3 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Note: Dots (.) indicate no sampling.
Table B-12 Mean Salinity (ppt) by Region and Week from 2005 Beach Seine Survey WEEK REGIONS BEGINNING MONDAY YK TZ CH IP WP CW PK HP KG SG CS AL 13JUN05 7.3 5.3 3.7 2.7 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.2 27JUN05 6.6 4.7 2.8 0.9 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 11JUL05 5.8 4.2 2.8 2.5 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 25JUL05 7.7 4.8 3.5 2.0 0.5 0.2 0.2 0.2 0.2 0.2 0.2 0.1 08AUG05 9.4 6.8 5.3 3.8 1.7 0.4 0.1 0.1 0.1 0.1 0.1 0.1 22AUG05 12.4 8.4 6.5 4.0 1.8 0.9 0.3 0.1 0.2 0.2 0.2 0.2 05SEP05 10.5 7.6 5.6 4.7 2.0 0.7 0.2 0.2 0.2 0.2 0.1 0.1 19SEP05 10.7 8.5 6.8 5.6 2.0 0.9 0.2 0.2 0.2 0.2 0.1 0.1 03OCT05 11.3 8.2 6.2 5.5 2.6 0.9 0.2 0.2 0.2 0.1 0.1 0.1 17OCT05 0.3 0.2 0.2 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Table B-13 Weighted Mean Dissolved Oxygen (mg/L) by Region and Week from 2005 Long River/Fall Juvenile Survey WEEK REGIONS BEGINNING MONDAY BT YK TZ CH IP WP CW PK HP KG SG CS AL 14MAR05 10.3 10.5 10.8 10.6 11.1 11.1 11.2......
21MAR05 10.7 11.3 11.1 11.0 11.5 12.3 12.4......
28MAR05 10.7 11.5 11.9 11.4 12.3 12.4 13.2......
04APR05 11.0 12.3 11.4 9.9 9.6 9.5 9.6 10.1 11.2 12.6 12.6 12.5 12.0 11APR05 8.6 9.5 10.0 10.5 10.7 10.8 11.2 10.7 10.5 10.4 10.3 10.7 11.7 18APR05 8.3 7.7 8.8 8.5 8.5 8.6 8.3 8.1 8.6 8.7 8.5 8.4 8.4 25APR05 8.3 8.8 9.1 9.0 9.4 9.8 10.1 10.0 9.9 10.4 9.3 9.0 9.3 02MAY05 9.1 10.1 10.7 10.5 9.8 9.6 9.5 9.5 9.4 9.6 9.5 9.8 10.3 09MAY05 7.7 8.2 8.5 8.7 8.6 8.7 8.8 8.6 8.9 8.4 8.6 9.3 10.5 16MAY05 7.9 7.5 7.4 7.6 7.7 10.0 10.1 9.8 10.4 10.2 9.2 8.4 8.7 23MAY05 8.0 8.4 8.0 7.8 7.9 8.6 9.1 9.4 9.1 9.3 9.2 8.5 8.6 30MAY05 6.3 6.4 7.5 7.8 8.0 8.5 8.8 8.5 8.6 8.9 9.1 8.9 9.0 06JUN05 7.0 7.4 7.5 7.6 7.7 8.6 8.6 8.8 8.4 8.0 8.3 9.0 9.0 13JUN05 8.0 8.1 7.8 6.6 6.6 6.4 6.6 7.1 8.9 7.5 7.3 8.3 7.7 20JUN05 5.5 5.7 6.6 7.5 7.2 7.5 7.4 7.6 7.0 6.2 6.2 7.1 8.1 27JUN05 5.6 6.0 6.7 5.6 5.3 6.4 8.0 7.3 6.7 7.4 7.9 7.9 7.7 04JUL05 6.0 6.0 5.7 6.0 5.8 6.0 6.2 5.9 6.5 6.8 7.5 7.0 6.9 11JUL05 5.6 5.9 5.9 5.9 6.2 6.3 6.6 6.5.....
18JUL05 4.9 5.1 5.9 5.8 5.6 5.9 6.3 6.6 6.8 6.8 6.9 7.1 6.4 25JUL05 4.3 5.3 6.3 6.5 5.0 5.4 5.4 5.3.....
01AUG05 5.3 6.0 6.6 6.3 5.5 4.9 5.4 5.5 6.5 6.5 7.0 7.0 6.7 08AUG05 5.2 6.3 5.9 6.1 5.2 5.6 6.3 6.3.....
15AUG05 4.4 4.6 5.7 5.3 4.4 4.5 4.7 5.2 5.6 6.1 6.2 6.1 6.1 22AUG05 4.6 4.9 5.1 5.6 6.4 7.1 7.6 7.6.....
29AUG05 5.2 5.9 6.0 6.3 6.2 5.5 5.7 5.5 5.4 6.5 6.9 6.7 6.8 05SEP05 6.2 6.0 5.9 5.0 6.4 5.9 6.3 6.2.....
12SEP05 5.5 5.4 6.2 6.0 6.0 6.2 6.4 7.0 7.6 6.0 6.0 6.4 7.1 19SEP05 6.6 5.9 6.4 5.8 6.8 6.8 7.2 7.7.....
26SEP05 4.2 4.7 5.2 5.6 5.5 5.8 6.1 6.3 6.8 6.5 6.8 6.5 7.1 03OCT05 5.0 5.1 5.8 6.1 5.0 6.1 7.5 9.3.....
10OCT05 7.2 6.7 6.4 7.1 7.0 7.0 7.2 7.4 7.9 7.6 7.7 8.2 9.6 24OCT05 9.0 9.1 8.6 9.3 9.4 9.5 9.0 9.0 9.4 10.3 10.2 10.3 10.6 07NOV05 6.9 7.5 8.2 9.4 10.0 10.3 10.0 10.6 10.8 10.8 10.5 11.2 12.1 28NOV05 7.4 8.1 8.9 9.8 10.5 11.8 11.8 11.9 12.6 12.3 11.7 11.4 11.8 Note: Dots (.) indicate no sampling.
Table B-14 Average Annual Dissolved Oxygen (mg/l) from Long River/Fall Juvenile Surveys, 1974 to 2005 YEAR DISSOLVED OXYGEN 1974 7.26 1975 7.69 1976 8.37 1977 7.66 1978 7.86 1979 8.02 1980 7.77 1981 7.82 1982 7.99 1983 8.29 1984 8.64 1985 8.14 1986 8.19 1987 7.79 1988 7.58 1989 7.58 1990 7.77 1991 7.10 1992 7.67 1993 7.59 1994 7.95 1995 7.90 1996 7.95 1997 7.91 1998 7.61 1999 7.56 2000 7.97 2001 7.54 2002 7.51 2003 7.51 2004 7.12 2005 7.04
Table B-15 Mean Dissolved Oxygen (mg/L) by Region and Week from 2005 Beach Seine Survey WEEK REGIONS BEGINNING MONDAY YK TZ CH IP WP CW PK HP KG SG CS AL 13JUN05 6.4 6.7 6.7 7.3 8.1 7.6 8.0 7.1 6.6 6.5 7.3 6.5 27JUN05 5.9 6.5 6.5 7.2 6.1 6.4 6.4 7.1 6.6 6.9 7.1 7.1 11JUL05 5.6 6.2 6.2 5.5 5.5 6.4 6.7 6.3 6.6 6.2 6.4 6.3 25JUL05 5.8 6.0 6.3 5.6 5.8 6.1 6.2 5.7 6.0 6.0 6.9 6.4 08AUG05 6.0 5.9 6.5 5.8 5.3 6.1 6.3 5.9 5.9 6.6 6.5 6.8 22AUG05 5.3 6.5 6.2 6.3 6.4 6.8 6.8 6.5 6.8 8.0 6.7 6.9 05SEP05 5.7 6.1 6.2 6.1 5.4 6.5 6.4 6.2 6.8 7.1 7.5 7.1 19SEP05 5.2 6.1 7.0 6.3 6.0 6.1 6.8 6.7 6.6 6.9 6.9 6.3 03OCT05 5.9 6.3 6.4 6.8 6.5 7.1 6.9 7.5 7.3 7.7 8.2 8.1 17OCT05 8.6 8.6 8.3 7.8 8.6 8.1 8.1 7.7 7.9 8.4 8.6 8.9
Table B-16 Average Annual Dissolved Oxygen (mg/l) from Beach Seine Surveys, 1974 to 2005 YEAR DISSOLVED OXYGEN 1974 8.71 1975 7.82 1976 7.89 1977 7.35 1978 7.29 1979 8.61 1980 8.08 1981 8.34 1982 7.85 1983 7.14 1984 8.42 1985 7.98 1986 8.28 1987 8.63 1988 7.95 1989 7.60 1990 7.90 1991 8.82 1992 8.56 1993 7.39 1994 8.33 1995 7.67 1996 6.93 1997 8.44 1998 7.42 1999 7.62 2000 7.38 2001 7.37 2002 6.76 2003 7.09 2004 7.20 2005 6.44
Table B-17 Weighted Mean Percent Oxygen Saturation by Region and Week from 2005 Long River/Fall Juvenile Survey WEEK REGIONS BEGINNING MONDAY BT YK TZ CH IP WP CW PK HP KG SG CS AL 14MAR05 84.6 82.0 82.6 80.1 80.4 79.5 80.1......
21MAR05 94.7 92.8 89.4 87.9 90.2 92.7 90.9......
28MAR05 88.8 92.9 93.1 88.8 96.5 97.0 102.6......
04APR05 92.5 98.5 93.3 80.6 77.7 78.3 79.5 81.6 90.2 100.8 101.1 101.3 97.5 11APR05 80.4 84.9 87.6 91.0 91.1 91.0 94.7 92.0 91.3 89.6 88.4 91.1 99.4 18APR05 81.6 73.7 83.6 78.6 78.0 77.1 74.9 73.5 79.2 80.9 78.9 78.4 78.7 25APR05 81.0 84.0 85.7 84.5 87.6 90.0 92.9 92.9 92.2 96.3 87.0 83.8 87.3 02MAY05 91.0 97.3 101.1 100.0 92.8 90.1 89.2 89.3 87.5 87.6 84.7 87.1 92.0 09MAY05 77.3 80.8 83.8 86.5 85.5 83.6 84.8 81.4 82.9 78.8 79.6 84.6 94.8 16MAY05 83.6 77.7 77.4 77.6 78.8 98.3 99.3 96.7 102.7 101.9 91.7 84.8 88.6 23MAY05 85.7 88.2 82.8 81.0 81.8 86.7 91.7 92.7 91.7 94.0 93.5 87.5 87.9 30MAY05 72.7 72.1 83.0 85.4 85.6 87.0 89.9 87.5 88.9 92.6 95.2 93.8 93.7 06JUN05 84.8 87.8 88.3 88.9 88.2 93.2 92.9 94.5 91.8 87.8 92.8 101.0 102.1 13JUN05 99.0 100.3 95.6 78.7 78.1 73.2 75.2 81.1 102.6 89.4 88.5 101.8 94.7 20JUN05 68.4 69.4 79.0 90.3 85.0 87.0 85.6 89.1 82.8 73.2 73.7 83.1 91.7 27JUN05 72.3 75.2 83.2 70.3 64.6 76.8 95.9 88.2 80.6 89.5 95.4 94.1 92.6 04JUL05 76.2 76.5 71.2 75.0 72.3 72.4 75.8 71.9 79.0 83.2 91.3 85.2 83.5 11JUL05 72.2 74.7 74.8 75.1 77.6 77.2 80.5 80.5.....
18JUL05 66.1 66.7 76.8 75.8 72.1 70.7 78.3 83.0 83.5 84.7 85.5 87.4 79.0 25JUL05 58.7 71.4 83.7 86.8 66.2 67.0 68.5 68.4.....
01AUG05 72.0 81.6 88.4 84.8 71.5 62.6 68.3 69.6 82.0 82.8 88.2 88.2 84.9 08AUG05 72.2 85.8 79.1 82.7 70.0 73.6 82.4 82.5.....
15AUG05 61.1 63.1 77.6 71.4 59.3 59.8 61.9 67.8 72.0 78.0 79.0 78.6 77.5 22AUG05 63.3 65.6 67.5 74.6 85.2 91.1 96.9 97.3.....
29AUG05 71.7 78.9 78.0 83.5 81.6 70.9 73.3 70.4 67.8 80.0 83.2 81.8 82.7 05SEP05 83.1 78.3 75.7 64.3 83.0 73.9 77.8 76.2.....
12SEP05 75.7 73.1 81.1 79.4 78.4 78.7 80.9 88.2 93.8 71.2 71.3 75.7 83.9 19SEP05 87.2 76.8 81.8 73.8 88.3 85.3 89.0 93.6.....
26SEP05 55.9 59.5 64.8 69.9 67.8 69.9 72.3 75.0 79.0 74.7 77.2 74.1 80.2 03OCT05 64.7 63.3 70.9 73.6 61.3 72.0 87.0 107.0.....
10OCT05 88.3 78.1 73.7 78.6 76.7 75.6 77.4 78.1 81.5 77.4 78.4 82.4 96.7 24OCT05 96.9 93.4 88.5 92.5 91.2 91.2 85.0 83.2 84.5 90.0 88.3 89.2 90.8 07NOV05 72.2 74.8 77.4 85.2 89.4 90.8 88.7 92.7 94.7 95.1 93.5 100.7 109.7 28NOV05 73.0 75.4 79.5 85.7 89.6 96.2 96.8 95.6 98.2 98.5 93.1 92.3 97.2 Note: Dots (.) indicate no sampling.
Table B-18 Mean Percent Oxygen Saturation by Region and Week from 2005 Beach Seine Survey WEEK REGIONS BEGINNING MONDAY YK TZ CH IP WP CW PK HP KG SG CS AL 13JUN05 78.6 81.9 81.9 87.6 94.1 90.1 93.7 83.6 79.0 79.1 90.9 80.8 27JUN05 75.0 82.0 79.3 88.4 74.4 77.0 77.4 83.8 80.8 84.1 86.8 86.5 11JUL05 72.3 80.0 78.0 71.0 67.9 80.1 85.4 77.5 80.0 76.0 78.6 74.8 25JUL05 75.6 77.8 82.9 74.1 72.1 79.0 76.8 68.1 71.1 73.0 87.9 80.0 08AUG05 80.0 79.2 89.4 79.4 69.6 79.4 82.7 75.0 73.5 83.0 83.9 85.1 22AUG05 71.2 84.7 78.5 81.3 80.7 85.0 84.9 78.7 83.7 100.5 81.9 83.1 05SEP05 75.2 77.4 80.4 78.9 68.3 82.0 79.0 74.4 81.0 86.8 92.3 83.9 19SEP05 67.1 78.1 89.5 82.6 74.5 75.3 82.6 78.8 78.5 83.2 82.7 73.4 03OCT05 71.3 74.2 76.5 82.8 77.0 83.5 78.8 83.0 79.8 86.7 91.9 87.4 17OCT05 84.7 85.5 84.8 82.0 85.3 80.7 80.3 75.5 77.5 82.3 83.5 85.7
Table B-19 Weighted Mean Conductivity (mS/cm @ 25°C) by Region and Week from 2005 Long River/Fall Juvenile Survey WEEK REGIONS BEGINNING MONDAY BT YK TZ CH IP WP CW PK HP KG SG CS AL 14MAR05 23.0 10.4 5.6 4.7 0.4 0.3 0.3......
21MAR05 29.3 15.8 13.4 11.5 9.3 5.5 1.3......
28MAR05 12.6 6.3 2.3 0.3 0.3 0.3 0.3......
04APR05 11.0 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 11APR05 20.3 8.0 3.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 18APR05 23.9 14.0 7.1 7.9 5.1 1.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 25APR05 17.9 7.8 4.0 1.4 0.7 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 02MAY05 25.3 9.7 0.8 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 09MAY05 18.1 9.1 3.6 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 16MAY05 20.2 9.1 8.5 4.9 4.3 1.0 0.2 0.2 0.2 0.2 0.2 0.2 0.2 23MAY05 24.3 18.5 12.7 9.0 6.1 4.2 2.4 0.2 0.2 0.2 0.2 0.2 0.2 30MAY05 30.9 22.3 12.1 7.8 4.1 1.1 0.6 0.2 0.2 0.2 0.2 0.3 0.3 06JUN05 27.2 18.2 13.0 8.2 4.4 0.8 0.6 0.2 0.2 0.2 0.2 0.3 0.2 13JUN05 32.3 22.3 14.1 11.1 6.5 2.3 0.3 0.2 0.2 0.2 0.2 0.2 0.3 20JUN05 28.5 21.2 12.7 9.3 5.0 0.8 0.6 0.2 0.3 0.3 0.3 0.2 0.2 27JUN05 30.0 16.9 7.4 4.0 2.0 0.7 0.3 0.3 0.3 0.3 0.2 0.2 0.2 04JUL05 25.2 19.1 12.8 7.2 3.4 0.6 0.3 0.3 0.2 0.2 0.2 0.2 0.2 11JUL05 27.7 17.4 11.5 8.0 4.1 1.1 0.4 0.3.....
18JUL05 31.1 22.5 13.3 9.2 6.0 0.4 0.4 0.2 0.2 0.2 0.2 0.3 0.3 25JUL05 30.4 16.0 9.0 7.3 3.5 1.0 0.6 0.3.....
01AUG05 31.7 24.9 16.7 10.3 7.6 2.4 0.8 0.2 0.2 0.2 0.2 0.3 0.2 08AUG05 33.1 23.4 17.0 11.6 7.0 2.5 0.9 0.3.....
15AUG05 36.8 28.2 18.6 13.6 8.2 5.5 3.5 0.6 0.2 0.3 0.3 0.3 0.3 22AUG05 27.5 19.0 13.9 10.5 7.8 3.2 1.8 0.6.....
29AUG05 33.5 24.4 15.4 11.5 8.0 6.1 3.9 0.7 0.3 0.3 0.3 0.3 0.3 05SEP05 29.9 19.9 14.0 10.2 8.3 3.9 1.4 0.3.....
12SEP05 36.6 29.1 18.7 13.1 9.1 5.8 4.0 0.8 0.3 0.3 0.3 0.3 0.2 19SEP05 26.2 18.6 13.4 10.8 9.4 5.1 2.5 0.4.....
26SEP05 36.3 27.2 19.5 11.8 8.6 5.2 3.3 0.6 0.3 0.3 0.2 0.2 0.2 03OCT05 30.8 22.7 16.1 12.0 9.6 5.6 2.2 0.4.....
10OCT05 24.7 11.4 6.3 1.7 0.7 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 24OCT05 17.4 9.8 7.3 3.2 0.8 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 07NOV05 24.0 14.0 6.3 0.5 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 28NOV05 27.2 17.9 9.2 5.8 2.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 Note: Dots (.) indicate no sampling.
Table B-20 Mean Conductivity (mS/cm @ 25°C) by Region and Week from 2005 Beach Seine Survey WEEK REGIONS BEGINNING MONDAY YK TZ CH IP WP CW PK HP KG SG CS AL 13JUN05 12.5 9.2 6.4 4.7 0.6 0.3 0.2 0.2 0.2 0.3 0.3 0.3 27JUN05 11.4 8.1 4.9 1.6 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 11JUL05 10.1 7.3 4.9 4.3 0.5 0.3 0.3 0.2 0.2 0.2 0.2 0.2 25JUL05 13.2 8.4 6.2 3.5 0.9 0.4 0.3 0.3 0.3 0.3 0.3 0.2 08AUG05 15.9 11.7 9.2 6.7 3.0 0.7 0.3 0.2 0.3 0.3 0.3 0.3 22AUG05 20.8 14.3 11.3 7.0 3.2 1.6 0.5 0.3 0.3 0.3 0.3 0.3 05SEP05 17.8 13.1 9.6 8.2 3.5 1.2 0.3 0.3 0.3 0.3 0.3 0.2 19SEP05 18.1 14.5 11.8 9.8 3.5 1.6 0.3 0.3 0.3 0.3 0.2 0.2 03OCT05 19.0 14.0 10.8 9.4 4.7 1.7 0.3 0.3 0.3 0.3 0.3 0.3 17OCT05 0.6 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2