ML073030493

From kanterella
Jump to navigation Jump to search
ERDS Data Point Library Revisions
ML073030493
Person / Time
Site: Callaway Ameren icon.png
Issue date: 10/10/2007
From: Diya F
AmerenUE
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
ULNRC05441
Download: ML073030493 (9)


Text

{{#Wiki_filter:AmarenUE Cal/away Plant PO Box 620 Fulton, MO 65251 October 10, 2007 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop P1-137 Washington, DC 20555-0001 ULNRC05441 WAmeren Uf Ladies and Gentlemen: DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO. FACILITY OPERATING LICENSE NPF-30 Callaway Plant ERDS Data Point Library Revisions Ref-

1) 10 CFR 50, Appendix E.VI.3.a
2)

NUREG - 1394, Revision 1 This correspondence is submitted in accordance with 10CFR50 Appendix E section VI.3.a, which requires any hardware and software changes that affect the transmitted data points identified in the ERDS Data Point Library be submitted to the NRC within 30 days after the changes are completed. Please find attached revision pages for the Callaway Plant's ERDS data point library reference file. These changes reflect changes made to Callaway's meteorological tower on 10/9/07. Please,contact Mr. Lewis Beaty, Computer Systems (573) 676-8632 for any questions. This letter does not contain new commitments. Sincerely, F. M. Diya Plant Director Enclosure (6 pages, 4, 62-66) a subsidiary ofAmeren Corporation

ULNRC05441 October 10, 2007 Page 2 cc: U.S. Nuclear Regulatory Commission Attn: Tom Kardaras Mail Stop T-4L7 Washington, DC 20555-0001 Mr. Elmo E. Collins, Jr. Regional Administrator U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-4005 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Jack N. Donohew (2 copies) Licensing Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop O-8G14 Washington, DC 20555-2738

ULNRC05441 October 10, 2007 Page 3 Index and send hardcopy to QA File A160.0761 Hardcopy: Certrec Corporation 4200 South Hulen, Suite 422 Fort Worth, TX 76109 (Certrec receives ALL attachments as long as they are non-safeguards and public disclosed). Electronic distribution for the following can be made via Other Situations ULNRC Distribution: C. D. Naslund A. C. Heflin L. H. Graessle G. A. Hughes S. A. Maglio S. L. Gallagher L. M. Belsky (NSRB) T. B. Elwood J. W. Hiller L. S. Beaty Ms. Diane M. Hooper Supervisor, Licensing WCNOC P.O. Box 411 Burlington, KS 66839 Mr. Scott Bauer Regulatory Affairs Palo Verde NGS P.O. Box 52034, Mail Station 7636 Phoenix, AZ 85072-2034 Mr. Scott Head Supervisor, Licensing South Texas Project NOC Mail Code N5014 P.O. Box 289 Wadsworth, TX 77483 Mr. Dennis Buschbaum TXU Power Comanche Peak SES P.O. Box 1002 Glen Rose, TX 76043 Mr. Stan Ketelsen Manager, Regulatory Services Pacific Gas & Electric Mail Stop 104/5/536 P.O. Box 56 Avila Beach, CA 93424 Mr. John O'Neill Pillsbury Winthrop Shaw Pittman LLP 2300 N. Street N.W. Washington, DC 20037 Missouri Public Service Commission Governor Office Building 200 Madison Street PO Box 360 Jefferson City, MO 65102-0360

J-26060A Rev. 4 CRITICAL SAFETY FUNCTION PARAMETERS COMPUTER PARAMETER DESCRIPTION UNITS POINT PARAMETER MISCELLANEOUS PARAMETERS BWST LEVEL WIND SPEED WIND SPEED WIND DIR WIND DIR STAB CLASS Borated Water Storage Tank Level Wind Speed at the Reactor Site Wind Speed at the Reactor Site Wind Direction at the Reactor Site Wind Direction at the Reactor Site Air Stability at the Reactor Site MPH MPH DEGFR DEGFR STABI REU0511 RDS5010A RDS5060A RDZ5010A RDZ5060A RSTX000P 4

J-26060A Rev. 4 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/08/2007 CWI N/A WIND SPEED RDS5010A MET TWR 10M A WIND SPEED WINDSPEED AT REACTOR SITE A,' MPH N/A 0.OOOE+00 1.OOOE+02 N/A N/A S1 N/A MET TOWER AT 10 METERS ELEVATION HIHI/HI/LO/LOLO 40 /NA/NA/NA N/A N/A LOW N/A N/A 62

J-26060A Rev. 4 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: -PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/08/2007 CWI N/A WIND SPEED RDS5060A MET TOWER 60M A WIND SPEED WIND SPEED AT REACTOR SITE A MPH N/A 0.OOOE+00 1.000E+02 N/A N/A S 1 N/A MET TOWER AT 60 METERS ELEVATION N/A N/A N/A LOW N/A N/A 63

J-26060A Rev. 4 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/08/2007 CWI N/A WIND DIR RDZ5010A MET TOWER 10M A WIND DIRECTION WIND DIRECTION AT REACTOR SITE A DEGFR N/A 0.000E+00 3.600E+02 N/A N/A S 1 N/A MET TOWER AT 10 METERS ELEVATION N/A N/A N/A LOW N/A N/A MEASURED IN THE "FROM" DIRECTION. 0 DEG = NORTH. MAY FAIL IN ANY MODE. 64

J-26060A Rev. 4 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/08/2007 CWI N/A WIND DIR RDZ5060A MET TOWER 60M A WIND DIRECTION WIND DIRECTION AT REACTOR SITE A DEGFR N/A 0.OOOE+00 3.600E+02 N/A N/A S 1 N/A MET TOWER AT 60 METERS ELEVATION N/A N/A N/A LOW N/A N/A MEASURED IN THE "FROM" DIRECTION. 0 DEG = NORTH. MAY FAIL IN ANY MODE. 65

J-26060A Rev. 4 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/08/2007 CWI N/A STAB CLASS RSTXO0OP MET TWR A STABILITY AIR STABILITY AT REACTOR SITE A STABI N/A 1.OOOE+00 7.OOOE+00 N/A N/A P 7 N/A MET TOWER N/A N/A N/A LOW N/A N/A STABILITY PRIMARILY BASED ON RATE OF VERTICAL.TEMPERATURE CHANGE. IF NOT VALIDATED GOOD, STABILITY IS BASED ON STANDARD DEVIATION OF WIND DIRECTION WHEN WIND SPEEDS ARE ABOVE 1 M/S. VALIDATION CRITERIA USED: STABILITY CLASS DOES NOT CHANGE BY MORE THAN 1 CLASS IN 15 MINUTES OR 2 CLASSES IN 1 HOUR. 1 2 3 4 5 6 7 = EXTREMELY UNSTABLE = MODERATELY UNSTABLE = SLIGHTLY UNSTABLE = NEUTRAL = SLIGHTLY STABLE = MODERATELY STABLE = EXTREMELY STABLE 66}}