ML071300536
| ML071300536 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 01/17/2007 |
| From: | Sandike S Entergy Nuclear Operations |
| To: | Noggle J NRC/RGN-I/DRS/PSB2 |
| References | |
| FOIA/PA-2007-0166, RG-1.109 | |
| Download: ML071300536 (2) | |
Text
1L!LamesNoggle-R 1.109 dose calc on Roseton fish RgoPage J1i From:
"Sa)'ike, Steven Richard" <SSandik@entergy.com>
To:
<jdn@nrc.gov>
Date:
Wed, Jan 17, 2007 4:43 PM
Subject:
Rg 1.109 dose calc on Roseton fish Jim....
This simple eval does not account or discuss any of the finer elements of error propogation, critical level, environmental BKGD or constants for non-random error, and other improvements we are discussing with labs... but simply chugging through the RG 1.109 model I get:
> With 25 pCi/kg of Sr-90 in fish, and ONLY looking at fish, we just
> multiply this by RG 1.109 ingestion dose factors in mrem/pCi, and
> usage factors, in kg/yr.
//---- RG 1.109=ODCM ------- \\
Field mrem/pCi kg/yr
> expected human dose term, annually, conc dose factor usage factor to
> the BONE, critical organ.
> Adult 25
- 7.58E-3
- 21
=
3.98 mrem in a year
>39.8% \\
> Teen 25
- 8.30E-3
- 16
=
3.32 mrem in a year
> 33.2 %
Annual Limit
> Child.25
- 1.70E-2
- 6.9
=
2.93 mrem in a year
>29.3% /
> Infant 25
- 1.85E-2
- 0
=
0 (IPEC uses these numbers in the ODCM... standard RG 1.109 values, nothing site specific here....)
> This indicates to me that the 25 pCi/kg at Roseton, if consumed like
> our ODCM says for our critical receptor, would result in less than 40%
> of the annual limits.
'Or we could say that about 62.5 pCi/kg = the 10CFR50 human dose
> limit for bone dose of 10 mrem.
Clearly all the other assumptions of the model make this very conservative, but it's a starting point.
I hope this is in the ball field of what you were looking for.... We have a lot more work to do with the lab, including sending some blanks, splits, spikes, from OUR chem lab and working out an INTERLAB program form someone. Adding some degree of Reg Guide 4.15 to GW is in our corrective action program due in March, but of course we are working on it now.
> Steve Sandike
> Effluents / RMS
> ENN Indian Point Energy Center
> Buchanan, NY 10511-0308
> phone: 914-736-8455
> fax:
914-734-6010
> email: ssandik@entergy.com
11 James Nocicile - RQ 1. 109 dose calc on Roseton f ish Pacie 2 11
-ame Nojl c.0 oecico oeo ihPq 1
N
> CONFIDENTIALI NOTICE: This elec nic message contains information
> which may be legall onfidential and/
privileged and does not in
> any case represent a fi ENERGY OMMODITY bid or offer relating
> thereto which binds the se er wit out an additional express written
> confirmation to that effect. Th ' ormation is intended solely for
> the individual or entity named o
and access by anyone else is
> unauthorized. If you are not t inten d recipient, any disclosure,
> copying, distribution, or us of the conte s of this information is
> prohibited and may be u awful. If you hav eceived this electronic
> transmission in error, ease reply immediatelto the sender that you
> have received the ssage in error, and delete Thank you. Have a
> pleasant day.
CC:
"Donahue, Patrick J" <PDonahu@entergy.com>, "Hinrichs, Gary H"
<ghinric@entergy.com>, "Lavera, Ronald" <RLavera@entergy.com>