Email from L. Dewald, Entergy, to R. Emch Dated 4/6/2007, NRC, Providing Extended Power Uprate Cooling Tower Evaporative Loss Study for Vermont Yankee
ML070990410
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 04/06/2007
From: Dewald L
Entergy Corp
To: Emch R
Office of Nuclear Reactor Regulation
References
Download: ML070990410 (3)


Text

Richard Emch - FW: Vermont Yankee Question..

page1 From:

"DeWald, Lynn" <ldewald@entergy.com>

To:

"Richard Emch" <RLE@nrc.gov>

Date:

04/06/2007 11:31:00 AM

Subject:

FW: Vermont Yankee Question Rich, As requested.


Original Message -----

From: Thomas, George Sent: Thursday, April 05, 2007 4:27 PM To: DeWald, Lynn Cc: McElwee, David

Subject:

FW: Vermont Yankee Question The 183 gpm drift is based on the cooling tower manufacture's data for drift of 0.05% of cooling tower water flow of 366,000 gpm. See p. 4 of attached report that was submitted in VT PSB Docket 6812 (EPU CPG).

The deposition was a simple calculation by S&W that was prepared to counter the NEC allegation that we would turn the site into a rain forest. It was submitted in response to a discovery request by NEC in the latter stages of the discovery process (same time gluteraldehyde appeared). Unfortunately, my files on this information were inadvertently deleted, and we will need to go back to Vickie Brown's files to obtain the information.

Maybe Dave McElwee can assist.

George S. Thomas Entergy Nuclear Operations, Inc.

Senior Project Manager Office: (802) 451-3072 Cell: (802) 380-4206


Original Message -----

From: DeWald, Lynn Sent: Thursday, April 05, 2007 9:08 AM To: Thomas, George

Subject:

FW: Vermont Yankee Question George, I left you a voicemail about seeking the information that the NRC requests below. Please give me a call. Lynn


Original Message -----

From: Richard Emch [1]

Sent: Thursday, April 05, 2007 8:55 AM

  • To: DeWald, Lynn Cc: Ellen Moret; Ron Kolpa; Jessie Muir

Subject:

Fwd: Vermont Yankee Question

Lynn, This an email from our contract staff at ANL. The air quality reviewer needs to get the document that is being referred to by the NEC comments.

Richard Emch - FW: Vermont Yankee Question Page?

Richard Emch - FW: Verm-ont, Yankee Question Paqe 2 Rich Emch

>>> "Moret, Ellen N." <moret@anl.gov> 04/04/2007 2:55 PM >>>

Hi Jessie--

In looking over some of the comments, Ron Kolpa asked me about a report referenced in comment letter #28 (New England Coalition). On the bottom of page 5-page 6, the commenter writes, "is staff unaware that according to discovery materials provided by Entergy in a hearing before the Vermont Public Service Board (Docket 6812), in the normal course of operation, Vermont Yankee NPP cooling towers discharge "drift" or spray at the rate of 183 gallons per minute. According to Entergy, ground deposition of this drift has been measured at 1/10 of inch per year at a

distance of 1000 meters, and the amount of drift will increase as thermal power is increased at the plant."

I know that Docket 6812 deals with the uprate, but Ron has never seen the report nor is aware of those numbers or where they come from. Do you have any idea what the report is, or where it may be obtained? We can always discuss this next week, but I thought it may help to have the report to look it over before then. Let me know, thanks.

Ellen

' c:\\temp\\GW)00001.TMP P*ge 1 *1 i~~~TM P.

.Pa..

ge 1 Mail Envelope Properties (461667AB.DF4: 12 : 11764)

Subject:

Creation Date From:

Created By:

FW: Vermont Yankee Question 04/06/2007 11:30:43 AM "DeWald, Lynn" <ldewald(ientergy.com>

ldewald(aentergy.com Recipients nrc.gov OWGWPOO2.HQGWDO01 RLE (Richard Emch)

Post Office OWGWPOO2.HQGWDOOI Files MESSAGE VY CT Evap RI 2003-06-11 Mime.822 Options Expiration Date:

Priority:

ReplyRequested:

Return Notification:

Concealed

Subject:

Security:

Route nrc.gov Size 2776

.pdf 517630 None Standard No None No Standard Date & Time 04/06/2007 11:30:43 AM 374435 Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled