ML070940504

From kanterella
Jump to navigation Jump to search
Ltr from Orise Dtd 01/12/2007, Final Letter Report for Requested Analyses of Six Water Samples, Set Eleven, from the Indian Point Power Station, Buchanan, New York (Inspection Report No. 05000247/2006-007) (Rfta No.06-001)
ML070940504
Person / Time
Site: Indian Point Entergy icon.png
Issue date: 01/12/2007
From: Condra D
Oak Ridge Institute for Science & Education
To: Kottan J
NRC Region 1
References
IR-06-007, RFTA 06-001
Download: ML070940504 (11)


Text

OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION January 12,2007 Mr. Jim Kottan U.S. Nuclear Regulatory Commission Regon I 475 Allendale Road King of Prussia, PA 19406

SUBJECT:

FINAL LETTER REPORT FOR REQUESTED ANALYSES OF SIX WATER SAMPLES, SET ELEVEN, FROM THE INDIAN POINT POWER STATION, BUCHANAN, NEW YORK

[INSPECTION REPORT NO. 050-247/2006-0071 [RFTA NO. 06-0011

Dear Mr. Kottan:

The Oak Ridge Institute for Science and Education (ORISE) received set eleven, which consisted of six water samples received on September 11,2006 from the Indlan Point Power Station in Buchanan, New York. Sample analysis was initiated based on your previous bection for handhg samples from h s fachty. The final letter report was delayed unul problems associated with americium and plutonium in water were resolved by the Intercomparison Test Program conducted by the Radlologcal and Environmental Sciences Laboratory. Sample identification and collection data for the samples addressed in h s report are presented in Table

1. Gamma spectroscopy, total ralostrontium, the hard-to-detect betas (iron-55, nickel-59/63, and tritium), technetium-99, alpha spectroscopy, plutonium-241, and carbon-1 4 data are provided in Tables 2 through 8, respectively. The pertinent procedure references are provided in each specific table.

ORISE's Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request.

The water samples were processed using a deviation to the sample preparation procedure, SP3, Revision 4. The water samples were filtered through 0.45 micron and 0.1 micron filter papers.

An aliquot was removed for tritium and carbon-14 before acidification. An aliquot was removed for alpha analysis and the pH was adjusted to approximately zero using concentrated nitric acid (HNO3) and a few drops of hydrofluoric acid (HF). A pH of zero and a few drops of HF should ensure that any plutonium that may be in the sample remains in solution. The remaining aliquot of each sample was adjusted to a pH of approximately 2 with concentrated HN03.

Mr. Jim Kottan famay 12,2006 Distribution approval and concurrence :

My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.

I Initials Sincerely, Distribution approval and concurrence :

Technical Management Team Member Quality Manager Dale Condra, Manager Laboratory Initials RD c :wPI :km Enclosures cc:

B. Watson, FSME/DWMEP/DD/SP 7E18 E. Ihox-Davin, NRC/FSME/TWFN 8A23 M. Roberts, NRC Region I File 1697 E. Abelquist, ORISE S. IGrk, ORISE J. Whte, NRC Regon I Voice: 865.241.3242 Fax: 865.241.3248 E-mail: Dale. Condra@orau. org

TABLE 1 ORISE Sample ID 1697W0061" SAMPLE IDENTIFICATIONS AND COLLECTION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Collection Collection Sample ID Date Time MW-30 74' Depth 8/18/2006 14:45 1697M0025 1697W0063 1697M0026 1697W0064 1697M0027 11 1697M0024b I MW-3074'Depth I 8/18/2006 I 14:45 11 MW-30 88' Depth 8/22/2006 13:15 MW-53 80' Depth 8/23/2006 12:50 MW-53 80' Depth 8/23/2006 12:50 MW-53 120' Depth 8/30/2006 11:30 MW-53 120' Depth 8/30/2006 11:30 11 1697W0062 I MW-30 88'Depth I 8/22/2006 I 13:15 11 1697M0028 1697W0066 1697M0029

~

MW-55 78' Depth 8/25/2006 9:20 MW-57 45' Depth 8/24/2006 9:30 MW-57 45' Depth 8/24/2006 9:30 11 1697W0065 I MW-5578'Depth I 8/25/2006 I 9:20 11

  • l'he W in thc ORISE sample identification represents a water matrix.

b'rhe M in the ORISE sample identification represents the filtcred fraction of the preceding water sample.

Indian Point Power Station projects/l697/Data Tables/2007-01-12 Data Tables Set Eleven

TABLE 2 ORISE Sample ID 1697W0061 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN WATER SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 15 INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Radionuclide Concentrationsa (pCi/L)

Sample ID CO-58 CO-60 cs-134 cs-137 b

MW-30 74'Depth

-1.4 k 3.4 4.7 k 4.2 -5.1 k 5.3 10.6 f 4.6 1697~0062 1697W0063 1697Y6'0064 1697YVoo65 1697W0066 MW-30 88'Depth

-0.6 k 3.4 -2.7 k 3.2 -0.5 t 3.4 2.3 k 2.9 MW-53 80'DePh 2.9 f 2.8 1.5 k 1.7 0.8 k 1.8 0.1 k 1.6 MW-53 120' Depth

-0.9 k 2.5 1.4 k 2.4 -3.1 k 2.9 1.4 f. 3.3 MW-55 78'Deph 1.2 k 2.7 1.2 k 2.2 -3.6 f. 3.8 3.7 k 2.7 MW-57 45'Depth

-1.1 k 2.5 0.2 k 2.2 2.5 k 2.6 2.2 f. 3.9 "The range of MDCs for the selected radionuclides is 2.9 pCi/L to 5.7 pCi/L.

'Uncertainties represent the 95% confidence level, based on total propagated uncertainties Indian Point Power Station projects/l697/Data Tables/2007-01-12 Data Tables Set Eleven

TABLE 3 ORISE Sample ID CONCENTRATIONS OF TOTAL RADIOSTRONTIUM IN WATER SAMPLES BY LOW BACKGROUND BETA COUNTING AP4, REVISION 13; CP3, REVISION 2 INDIAN POINT POWER STATION BUCHANAN, NEW YORK

~ _ _ _ _

~~

Radionuclide NRC Region I Concentrations, Sample ID TPUs, and MDCsa

@Ci/L) 1697W0061 1697W0062 MW-30 74'Depth 1.0 k l.lb (1.8)

MW-30 88' Depth 0.5 k 1.1 (1.9) 1697W0063 1697W0064 1697W0065 1697W0066 "MDCs are in parentheses buncertainties represent the 95?h confidence level, based on total propagated unccrtainties MW-53 80'Deph 8.61 f 0.73 (0.75)

MW-53 120' Depth 16.9 k 1.0 (0.8)

Mw-55 78' Depth 28.2 2 1.3 (0.7)

MW-57 45'Depth 21.8

  • 1.2 (0.8)

Indian Point Power Station projects/l697/Data 'l'ables/2007-01-12 Data Tables Set Eleven

3 3

L1.

ORISE Sample ID TABLE 4 Radionuclide Concentrationsa @Ci/L)

NRC Region I Sample ID Fe-55b Ni-59' Ni-63' H-3d CONCENTRATIONS OF HARD TO DETECT BETA EMITTING RADIONUCLIDES IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK 1697W0061 1697W0062 1697W0063 1697W0064 1697W0065 MW-3074'Depth 9 1 28' (48)

-16 k 13 (23) 15 ? 22 (36) 259,200 k 8,700 (400)

MW-3088'Depth 7 t 28 (48)

-9 t 13 (23) 8 2 22 (36) 14,610 rt 580 (190)

MW-53 80'Depth 10 -t 28 (48)

-6.9 f 5.2 (9.0) 9.1 f 8.7 (14.6) 13,260 f 540 (190)

MW-53 120'Depth 7 t 28 (48)

-1.6 t 5.3 (9.0) 12.4 t 8.8 (14.6) 4,320 t 250 (190)

MW-55 78'Depth 9 t 28 (48)

-2.8 2 5.3 (9.0) 7.7 & 8.7 (14.6) 16.700 rt 650 (190) 1697W0066 I MW-57 45'Depth 1-13 k 28 (48) I -10.1 k 5.1 (9.0) I 7.9 k 8.7 (14.6) I 4,200

? 240 (190)

"The MDCs for each radionuclide are in parentheses bFe-55 analyzed using procedure AP13, Revision 4

'Ni-59/63 analyzed using procedure APl7, Revision 0.

dH-3 analyzed using procedure AP2, Revision 15 eUncertainties represent the 95% confidence level, based on total propagated uncertainties.

TABLE 5 ORISE Sample ID 1697W0061 1697W0062 1697W0063 CONCENTRATIONS OF TECHNETIUM-99 (Tc-99)

IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP5, REVISION 16; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Tc-99 NRC Region I Sample ID Concentrationsa (pCi/L)

MW-30 74' Depth 2

?

19b (32)

MW-30 88' Depth 7

?

19 (32)

MW-53 80'Depth 1.9 k

9.3 (16.0) 1697W0064 1697W0065 1697W0066 MW-53 120' Depth 6.8

-t 9.5 (16.0)

MW-55 78'Depth 3.1

-t 9.4 (16.0)

MW-57 45'Depth 7.8 ?

9.5 (16.0)

Indian Point Power Station projects/l697/Data Tables/2007-01-12 Data Tables Set Eleven

TABLE G ORISE Sample NRC Region I ID Sample ID 1697W0061 m-3074'DePh 1697M0024 m-3074'DePth 1697W0062 m-3088'DePh 16971110025 m-3088'DePth 1697W0063 m - 5 3 80'DePh 1697M0026 m - 5 3 80'DePth 1697W0064 m - 5 3 120'DePh 1697M0027 a - 5 3 120'DePfi 1697W0065 m-5578'DePth 1697M0028 m - 5 5 78'DePh 1697W0066 m-5745'DePth 1697M0029 m-5745'DePh 0

8 2 a

5 ci ?

w 8

-I s 0

a

-4

\\

\\

N L

N B

if

g.

Radionuclide Concentrationsa @Ci/g of sediment in 100 mL or pCi/L for water) 0.11 k 0.34b (0.63) 0.04 k 0.17 (0.35) 0.04 f 0.24 (0.49) -0.07 f 0.14 (0.38) 0.01 '. 0.02 (0.03) 0.01

& 0.01 (0.02) -0.01 f 0.02 (0.03) 0.00' f 0.01 (0.02) 0.08 f 0.24 (0.47) 0.19 f 0.17 (0.11) 0.00 f 0.15 (0.37) -0.04 f 0.13 (0.37) 0.01 f 0.02 (0.03) 0.01 2 0.01 (0.02) 0.00 2 0.01 (0.02) 0.00 f 0.01 (0.02) 0.06 f 0.08 (0.14) 0.02 f 0.04 (0.06) -0.04 f 0.05 (0.18) 0.00 f 0.05 (0.13) 0.01 f 0.02 (0.04) 0.01 f 0.01 (0.02) 0.02 f 0.02 (0.03) 0.00 4 0.01 (0.02)

-0.07 f 0.21 (0.42) -0.02 f 0.06 (0.18) -0.11 f 0.15 (0.34) -0.04 f 0.10 (0.24) 0.02 f 0.02 (0.03) 0.00 f 0.01 (0.03) 0.01 f 0.02 (0.03) 0.01 f 0.01 (0.02) 0.07 k 0.15 (0.27)

-0.02 4 0.08 (0.21) 0.06 k 0.08 (0.14) -0.10 f 0.09 (0.26)

-0.01 f 0.02 (0.04) 0.01 f 0.01 (0.02) -0.01 f 0.01 (0.03) 0.00 f 0.01 (0.03) 0.02 f 0.14 (0.29) 0.08 2 0.10 (0.15) 0.06 k 0.13 (0.25) 0.04 f 0.09 (0.18)

-0.01 f 0.02 (0.05) 0.01

+_ 0.01 (0.02) 0.00 k 0.01 (0.03) 0.03 f 0.02 (0.02)

Am-241 Cm-242 Cm-243/244 Np-237 CONCENTRATIONS OF SELECTED ALPHA EMITTING RADIONUCLIDES IN SUSPENDED AND DISSOLVED FRACTIONS OF WATER SAMPLES AP11, REVISION 3; CP2, REVISION 12 INDIAN POINT POWER STATION BUCHANAN, NEW YORK

TABLE 6 (Continued)

ORISE Sample ID CONCENTRATIONS OF SELECTED ALPHA EMITTING RADIONUCLIDES IN SUSPENDED AND DISSOLVED FRACTIONS OF WATER SAMPLES AP11, REVISION 3; CP2, REVISION 12 INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Sample ID Radionuclide Concentrationsa (pCi/g of sediment in 100 mL or pCi/L for water)

Pu-238 P~-239/240 I

U-234 I

U-238 1697M0024 1697W0062 1697M0025 1697W0063 1697M0026 1697W0064 1697M0027 1697W0061 I m-3074'DeP*

I 0.42 f 0.40 (0.64) I 0.10 f 0.15 (0.26) I 4.39 k 0.85 (0.38) I 3.12 k 0.72 (0.45) m-3074'DePth 0.03 k 0.03 (0.04) 0.01 1 0.01 (0.01) 0.00 A 0.01 (0.01) 0.00 A 0.01 (0.02) m-3088'Depth 0.19 f 0.37 (0.66) 0.23. f 0.19 (0.12) 2.52 ? 0.69 (0.39) 3.20 f 0.77 (0.31) m-3088'DePth 0.00 f 0.02 (0.05) 0.01 ? 0.01 (0.02) 0.04 f 0.02 (0.02) 0.06 f 0.02 (0.01) m - 5 3 80'DePth

-0.10 A 0.18 (0.37) 0.05 ? 0.08 (0.13) 3.16 k 0.51 (0.13) 1.94 &

0.39 (0.13) m - 5 3 80'DePth 0.01 f 0.02 (0.03) 0.01 A 0.01 (0.01) 0.43 ? 0.06 (0.02) 0.65 k 0.08 (0.02) m - 5 3 120'Depth 0.11 f 0.17 (0.28) 5.99 f 0.81 (0.27) 4.04 k 0.63 (0.18)

, m-53120'DePth, 0.01 k 0.02 (0.04), 0.00 k 0.01 (0.02), 1.99 k 0.19 (0.021, 1.86 k 0.18 (0.01) 1697W0065 1697M0028 1697W0066 1697M0029 m - 5 5 78'DePth 0.14 ? 0.19 (0.31) 0.06 ? 0.07 (0.06) 1.64 k 0.41 (0.29) 1.18 k 0.34 (0.27) m - 5 5 7 8 ' Depth

-0.02 2 0.02 (0.04) 0.00 2 0.01 (0.02) 0.00 ? 0.01 (0.03) 0.01 k 0.01 (0.02) m - 5 7 45'DePth 0.22 f 0.18 (0.27) 0.04 ? 0.05 (0.06) 1.48 2 0.35 (0.17) 1.49 ?

0.35 (0.06)

Mw-57 45'Depth 0.02 -t 0.02 (0.03) 0.01 5 0.01 (0.02) 2.03 ? 0.19 (0.02) 2.43 f 0.22 (0.02)

U E 4

%e MDCs are in parentheses.

hUncertainties represent the 95% confidence level, based on total propagated uncertainties.

Zero values are due to rounding.

G 6

3 m

c R

TABLE 7 ORISE Sample ID CONCENTRATIONS OF PLUTONIUM-241 IN SUSPENDED AND DISSOLVED FRACTIONS OF WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP10, REVISION 2; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Concentrationsa

@Ci/g of sediment in 100 mL or pCi/L for NRC Region I Sample ID 1

I I

Radionuclide "MDCs are in parentheses.

buncertainties represent the 95% confidence level, based on total propagated uncertainties.

Indian Point Power Station projects/l697/Data Tables/2007-01-12 Data Tables Set Eleven

.. I ORISE Sample ID Radionuclide NRC Region I Concentrations, Sample ID TPUs, and MDCsa (PCi/L)

TABLE 8 1697W0062 1697W0063 1697W0064 1697W0065 1697W0066 CONCENTRATIONS OF CARBON-14 I N WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP9, REVISION 3; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK MW-30 88'Depth

-4

& 10 (18)

MW-53 80'Depth

-4 10 (18)

MW-53 120'Depth 3

11 (18)

MW-55 78'Depth 0'

11 (18)

MW-57 45'Depth

-4 k 10 (18) 1 1 6 9 7 W 0 0 6 1 I MW-3074'Depth I -5 k IOb (18)

"MDCs are in parentheses.

buncertainties reprcsent the 95% confidence level, based on total propagated uncertainties

'Zero value is due to rounding.

Indian Point Power Station projects/l697/Data Table$/2007-01-12 Data Tables Set Eleven