ML063420601
| ML063420601 | |
| Person / Time | |
|---|---|
| Site: | Monticello |
| Issue date: | 12/08/2006 |
| From: | Tam P NRC/NRR/ADRO/DORL/LPLIII-1 |
| To: | Loeffler R, Salamon G Nuclear Management Co |
| References | |
| TAC MD3580 | |
| Download: ML063420601 (2) | |
Text
From:
Peter Tam To:
Loeffler, Rick; Salamon, Gabor Date:
12/08/2006 3:11:42 PM
Subject:
Monticello: Revised Draft RAI on LPCI Loop Select Time Delay Surveillance Req. (TAC MD3580)
Rick:
As discussed during today's teleconference with you, Ben Parks had revised the first question of the draft RAI as follows:
(1) Provide relevant documentation from three recent ECCS surveillances showing that the LPCI loop select time delay relays have been functional. Please note that the staff found the data referenced in the USAR and no longer needs time sequencing information as discussed during the conference call; only the ECCS surveillance documentation confirming the functionality of the time delay relay logic is necessary.
The staff agreed to delete draft Questions (2).
Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 CC:
Benjamin Parks; Cranston, Gregory Mail Envelope Properties (4579C6FE.2CF : 12 : 35330)
Subject:
Monticello: Revised Draft RAI on LPCI Loop Select Time Delay Surveillance Req. (TAC MD3580)
Creation Date 12/08/2006 3:11:42 PM From:
Peter Tam Created By:
PST@nrc.gov Recipients Action Date & Time nmcco.com Transferred 12/08/2006 3:12:15 PM Gabor.Salamon (Gabor Salamon)
Richard.Loeffler (Rick Loeffler) nrc.gov OWGWPO03.HQGWDO01 Delivered 12/08/2006 3:11:49 PM GVC CC (Gregory Cranston)
Opened 12/08/2006 3:13:51 PM nrc.gov TWGWPO03.HQGWDO01 Delivered 12/08/2006 3:11:49 PM
Opened 12/08/2006 3:11:59 PM Post Office Delivered Route nmcco.com OWGWPO03.HQGWDO01 12/08/2006 3:11:49 PM nrc.gov TWGWPO03.HQGWDO01 12/08/2006 3:11:49 PM nrc.gov Files Size Date & Time MESSAGE 1833 12/08/2006 3:11:42 PM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard ReplyRequested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard To Be Delivered:
Immediate Status Tracking:
Delivered & Opened