ML063420308
| ML063420308 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 11/06/2006 |
| From: | Ashley D NRC/NRR/ADRO/DLR |
| To: | Hufnagel J Exelon Corp |
| References | |
| %dam200701, TAC 8261 | |
| Download: ML063420308 (5) | |
Text
Pý
. Ashley -Fwd: AGRS AgendaPge1
..Page 11 From:
D. Ashley To:
John Hufnagel Date:
11/06/2006 10:24:21 AM
Subject:
Fwd: ACRS Agenda John-Here is a very draft Agenda that we feel will assist us in presenting a focused and complete picture to the ACRS subcommittee.
We are reviewing the questions that Tanny supplied to us, the notes that we made during the meeting and will compare to the agenda as we prepare for the next meeting on tentative scheduled for January 18.
Please review and comment as you see necessary
- regards, Donnie Ashley NRR/DLR/RLRA Oyster Creek License Renewal Project Manger 301-415-3191 dial @nrc.qov
>>> Noel Dudley 11/06/2006 >>>
CC:
Cayetano Santos; Michael Junge; Noel Dudley
Ic:\\tleMp\\GWLO 003.. 1 -MPP
.Page 1]
Mail Envelope Properties (454F53A5.B3A: 9:10848)
Subject:
Fwd: ACRS Agenda Creation Date 11/06/2006 10:24:21 AM From:
D. Ashley Created By:
DJA1 @nrc.gov Recipients Action exeloncorp.com Transfi 10:24:53 AM john.hufnagel (John Hufnagel) nrc.gov OWGWPOO3.HQGWDOO1 Delivei 10:24:28 AM NFD CC (Noel Dudley)
Opene 12:26:22 PM nrc.gov OWGWPOO4.HQGWDO01 Delivei 10:24:29 AM MXJ2 CC (Michael Junge)
Opene 10:31:21 AM nrc.gov TWGWPO02.HQGWDO01 Delivei 10:24:29 AM CXS3 CC (Cayetano Santos)
Opene 11:23:12 AM Post Office Delive OWGWPOO3.HQGWDOOI 06 Nov nrc.goN OWGWPOO4.HQGWDOOI 06 Nov nrc.gov TWGWPO02.HQGWDO01 06 Nov erred red d
Date & Time 06 November, 2006 06 November, 2006 06 November, 2006 06 November, 2006 06 November, 2006 06 November, 2006 06 November, 2006 red I
red I
red Route exeloncorp.cc ember, 2006 10:24:28 AM ember, 2006 10:24:29 AM rember, 2006 10:24:29 AM
& Time
)ember, 2006 10:24:21 AM
)vember, 2006 10:10:40 AM in Files MESSAGE TEXT.htm ACRS mtg Agenda.wpd Size 1423 1052 19385 nrc.goN Date 06 Nz 06 N
c:\\temp\\GW}00003.MP2 Page 2
- D. Ashley.vcf 302 08 August, 2006 2:46:52 PM 9
Options Auto Delete:
Expiration Date:
Notify Recipients:
Priority:
ReplyRequested:
Return Notification:
Concealed
Subject:
Security:
No None Yes Standard No None No Standard To Be Delivered:
Status Tracking:
Immediate Delivered & Opened
L1D. Ashley - ACR$ mtg Agenda.wpd Page 111 ACRS LICENSE RENEWAL SUBCOMMITTEE MEETING OYSTER CREEK LICENSE RENEWAL APPLICATION JANUARY 18, 2007
- 1.
Introduction 8:30 - 8:35 a.m.
II.
AmerGen Presentation A.
Drywell Shell 1.
8:35 - 10:00 a.m.
Sand Bed Area
- a.
Data Gathering
- b.
External UT Monitoring Points
- c.
GE Model
- d.
Interior UT Monitoring Points
- e.
Statistical Analyses
- f.
Coating monitoring program
- g.
2006 monitoring results (1)
Interior UT points (2)
Exterior UT points (3)
Coating BREAK
- 2.
Upper Shell
- a.
Data Gathering
- b.
UT Monitoring at Transitions C.
GE model
- d.
2006 monitoring results
- 3.
Embedded portions of the shell
- 4.
Water Leakage
- a.
Source of Water
- b.
Reactor Cavity
- c.
Liner Cracking
- d.
Strippable Liners
- e.
Inspection Program
- f.
Interior Trench Epoxy Inspections 10:00 - 10:15 a.m.
10:15 - 10:45 a.m.
10:45 - 11:15 a.m.
11:15 - 12:00 noon LUNCH 12:00 - 1:00 p.m.
1:00 - 1:20 p.m.
B.
Fork River Combustion Turbine C.
Socket Welds p.m.
D.
Stub Tubes 1:20 - 1:40 1:40 - 2:00 p.m.
D. Asle i-YcfH; mtg Agenda.wpd ae Paqge 2 i]
E.
Inaccessibl BREAK Staff Presentation Drywell Shelf e Cables 2:00 - 2:15 p.m.
2:15 - 2:30 p.m.
II1.
A.
- 1.
Sand Bed Area
- a.
Sandia Model
- b.
Coating monitoring program
- c.
Commitments
- d.
2006 monitoring results
- 2.
Upper Shell
- a.
UT Monitoring at Transitions
- b.
2006 monitoring results
- 3.
Embedded portions of the shell
- 4.
Water Leakage
- a.
Source of Water
- b.
Inspection Program 2:30 - 3:30 p.m.
3:30 - 3:40 p.m.
3:40 - 4:00 4:00 - 4:20 p.m.
4:40 - 5:00 p.m.
5:00 p.m.
B.
Fork River Combustion Turbine C.
Socket Welds p.m.
D.
Stub Tubes E.
Inaccessible Cables IV.
Adjournment