ML061710355

From kanterella
Jump to navigation Jump to search

Request for Use of ASME Code Case N-623 and Withdrawal of Pilgrim Relief Request No. PRR-12
ML061710355
Person / Time
Site: Pilgrim
Issue date: 06/06/2006
From: Bethay S
Entergy Nuclear Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
2.06.033, PRR-12, TAC MC8295
Download: ML061710355 (2)


Text

Entergy Nuclear Operations, Inc.

ý Enterg Pilrim Stto y

600 Rocky Hill Road Plymouth, MA 02360 Stephen J. Bethay Director, Nuclear Assessment June 6, 2006 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Entergy Nuclear Operations, Inc.

Pilgrim Nuclear Power Station Docket No. 50-293, License No. DPR-35 Request For Use of ASME Code Case N-623 and Withdrawal of Pilgrim Relief Request No. PRR-12 (TAC No. MC 8295)

REFERENCES:

1. Entergy Letter No. 2.05.045, ASME Section Xl Fourth Interval Inservice Inspection Program Plan and the Associated Relief Requests for NRC Approval, PNPS-RPT-05-001, Revision 0, dated June 29, 2005
2. ASME Code Case N-623, "Deferral of Inspections of Shell-to-Flange and Head-to-Flange Welds of a Reactor Vessel Section XI, Division 1, dated February 26, 1999
3. U.S. NRC Regulatory Guide 1.147, Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1", Revision 13 (January 2004) and Revision 14 (August 2005)

LETTER NO.

2.06.033

Dear Sir or Madam:

By Reference 1, Entergy submitted Pilgrim Relief Request (PRR) No. 12 for NRC review and approval for the 4th ISI interval that began on July 1, 2005. The relief requested included provisions that were incorporated in ASME Code Case N-623. This code case is acceptable for use as stated in NRC approved Regulatory Guide 1.147, Revisions 13 and 14. It has subsequently been annulled since its provisions were incorporated into the 2001/2003 version of the ASME Code Section Xl, Division 1.

Regulatory Guide 1.147, Revision 13, which lists Code Case N-623 as acceptable for use was the approved Guide in place at the time Entergy submitted the Pilgrim ISI program and associated PRR-12 for NRC review and approval in June 2005 (Ref. 1). The use of Code Case N-623 is referenced on page 1-25 of Reference 1.

Since Code Case N-623 was acceptable for use at the time Reference 1 was submitted, Entergy withdraws PRR-12 and will continue to use the ASME Code Case N-623 for the 4th ISI interval as an acceptable alternative pursuant to 10 CFR 50.55a(a)(3)(i). It was authorized in R.G. 1.147, Revision 13 pursuant to 10 CFR 50.55a (a)(3) and stipulated in 10 CFR 50.55a.

This use of ASME Code N-623 is consistent with the NRC guidance cited in the third paragraph (page 3) of R. G. 1.147, Rev. 14.

1gL{

Entergy Nuclear Operations, Inc.

Pilgrim Nuclear Power Station Letter Number: 2.06.033 Page 2 There are no commitments contained in this letter.

If you have any questions on this transmittal, please contact Mr. Bryan Ford, Licensing Manager at 508-830-8403.

Sincerely,

(-y2 Stephen J.

SJB/wgl cc:

Mr. James Shea, Project Manager Office of Nuclear Reactor Regulation Mail Stop: 0-8B-1 U.S. Nuclear Regulatory Commission 1 White Flint North 11555 Rockville Pike Rockville, MD 20852 U.S. Nuclear Regulatory Commission Region 1 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Pilgrim Nuclear Power Station