Correction to Amendments Relocation of Operability and Surveillance Requirements for the Safety/Relief Valve Position Instrumentation
ML053260143
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 11/22/2005
From: George Wunder
Plant Licensing Branch III-2
To: Crane C
Exelon Generation Co, Exelon Nuclear
Wunder G, NRR/DLPM, 415-1494
References
TAC MC3454, TAC MC3455
Download: ML053260143 (5)


Text

November 22, 2005 Mr. Christopher M. Crane President and Chief Nuclear Officer Exelon Nuclear Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348

SUBJECT:

LIMERICK GENERATING STATION, UNIT NOS. 1 AND 2 - CORRECTION TO AMENDMENTS RE: RELOCATION OF OPERABILITY AND SURVEILLANCE REQUIREMENTS FOR THE SAFETY/RELIEF VALVE POSITION INSTRUMENTATION (TAC NOS. MC3454 AND MC3455)

Dear Mr. Crane:

By letter dated September 27, 2005, the Nuclear Regulatory Commission (NRC) issued Amendment No. 179 to Facility Operating License No. NPF-39 and Amendment No. 141 to Facility Operating License No. NPF-85 for the Limerick Generating Station (LGS), Unit Nos. 1 and 2, respectively. These Amendments consisted of changes to the technical specifications (TSs) in response to your application dated June 1, 2004.

The TS pages that were issued with these Amendments did not reflect changes that were made by Amendment No. 173 to Facility Operating License No. NPF-39 and Amendment No. 135 to Facility Operating License No. NPF-85, for LGS Unit Nos. 1 and 2, respectively, which were issued by the NRC on April 13, 2005. Enclosed please find the correct TS pages, which need to be incorporated into your records.

Sincerely,

/RA/

George F. Wunder, Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-352 and 50-353

Enclosures:

As stated.

cc w/encls: See next page

Limerick Generating Station, Unit Nos. 1 and 2 cc:

Site Vice President Limerick Generating Station Exelon Generation Company, LLC P.O. Box 2300 Sanatoga, PA 19464 Plant Manager Limerick Generating Station Exelon Generation Company, LLC P.O. Box 2300 Sanatoga, PA 19464 Regulatory Assurance Manager - Limerick Exelon Generation Company, LLC P.O. Box 2300 Sanatoga, PA 19464 Senior Vice President - Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Operations, Mid-Atlantic Exelon Generation Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Vice President Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director Licensing and Regulatory Affairs Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Manager Licensing Limerick Generating Station Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Correspondence Control Desk Exelon Generation Company, LLC P.O. Box 160 Kennett Square, PA 19348 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector U.S. Nuclear Regulatory Commission Limerick Generating Station P.O. Box 596 Pottstown, PA 19464 Library U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Director, Bureau of Radiation Protection Pennsylvania Dept. of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Chairman Board of Supervisors of Limerick Township 646 West Ridge Pike Linfield, PA 19468 Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803

Mr. Christopher M. Crane President and Chief Nuclear Officer Exelon Nuclear Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348

SUBJECT:

LIMERICK GENERATING STATION, UNIT NOS. 1 AND 2 - CORRECTION TO AMENDMENTS RE: RELOCATION OF OPERABILITY AND SURVEILLANCE REQUIREMENTS FOR THE SAFETY/RELIEF VALVE POSITION INSTRUMENTATION (TAC NOS. MC3454 AND MC3455)

Dear Mr. Crane:

By letter dated September 27, 2005, the Nuclear Regulatory Commission (NRC) issued Amendment No. 179 to Facility Operating License No. NPF-39 and Amendment No. 141 to Facility Operating License No. NPF-85 for the Limerick Generating Station (LGS), Unit Nos. 1 and 2, respectively. These Amendments consisted of changes to the technical specifications (TSs) in response to your application dated June 1, 2004.

The TS pages that were issued with these Amendments did not reflect changes that were made by Amendment No. 173 to Facility Operating License No. NPF-39 and Amendment No. 135 to Facility Operating License No. NPF-85, for LGS Unit Nos. 1 and 2, respectively, which were issued by the NRC on April 13, 2005. Enclosed please find the correct TS pages, which need to be incorporated into your records.

Sincerely,

/RA/

George F. Wunder, Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-352 and 50-353

Enclosures:

As stated cc w/encls: See next page DISTRIBUTION:

PUBLIC LPL1-2 R/F DRoberts GWunder CRaynor MShanbaky, RI OGC ACRS GHill (4)

TBoyce CSchulten DORL DPR Accession Number: ML053260143 *SE input date. No major changes made.

OFFICE LPL1-2/PM LPL1-2/LA LPL1-2/BC NAME GWunder CRaynor DRoberts DATE 11/22/05 11/22/05 11/22/05 Official Record Copy

ATTACHMENT TO LICENSE AMENDMENT NO. 179 FACILITY OPERATING LICENSE NO. NPF-39 DOCKET NO. 50-352 Replace the following pages of the Appendix A Technical Specifications with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.

Remove Insert 3/4 3-85 3/4 3-85 3/4 3-87 3/4 3-87

ATTACHMENT TO LICENSE AMENDMENT NO. 141 FACILITY OPERATING LICENSE NO. NPF-85 DOCKET NO. 50-353 Replace the following pages of the Appendix A Technical Specifications with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.