ML050140385

From kanterella
Jump to navigation Jump to search

Tech Spec Pages for Amendment 220 Deletion of Requirements for Submittal of Occupational Radiation and Monthly Operating Reports
ML050140385
Person / Time
Site: Palisades Entergy icon.png
Issue date: 01/10/2005
From:
NRC/NRR/DLPM
To:
Jaffe D, NRR/DLPM, 415-1439
Shared Package
ML03350071 List:
References
TAC MC4623
Download: ML050140385 (2)


Text

Reporting Requirements 5.6 5.0 ADMINISTRATIVE CONTROLS 5.6 Reporting Requirements The following reports shall be submitted in accordance with 10 CFR 50.4.

5.6.1 (Deleted)

Radiological Environmental Operating Renort I

5.6.2 5.6.3 The Radiological Environmental Operating Report covering the operation of the plant during the previous calendar year shall be submitted before May 15 of each year. The report shall Include summaries, interpretations, and analysis of trends of the results of the radiological environmental monitoring program for the reporting period. The material provided shall be consistent with the objectives outlined In the Offsite Dose Calculation Manual and In 10 CFR 50, Appendix I, Sections IV.B.2, IV.B.3, and IV.C.

Radioactive Effluent Release Report The Radioactive Effluent Release Report covering operation of the plant in the previous year shall be submitted prior to May 1 of each year in accordance with 10 CFR 50.36a. The report shall Include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the plant.

The material provided shall be consistent with the objectives outlined in the Offsite Dose Calculation Manual and Process Control Program, and shall be in conformance with 10 CFR 50.36a and 10 CFR 50, Appendix I, Section IV.B.1.

Palisades Nuclear Plant 5.0-24 Amendment No. 49, 2443, AMD 220

Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.4 (Deleted) 5.6.5 CORE OPERATING LIMITS REPORT (COLR)

a.

Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented In the COLR for the following:

3.1.1 Shutdown Margin 3.1.6 Regulating Rod Group Position Limits 3.2.1 Unear Heat Rate Umits 3.2.2 Radial Peaking Factor Limits 3.2.4 ASI Limits 3.4.1 DNB Limits

b.

The analytical methods used to determine the core operating limits shall be those approved by the NRC, specifically those described In the latest approved revision of the following documents:

1.

EMF-96-029(P)(A) Volumes I and 2, 'Reactor Analysis System for PWRs," Siemens Power Corporation.

(LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)

2.

ANF-84-73 Appendix B (P)(A), "Advanced Nuclear Fuels Methodology for Pressurized Water Reactors: Analysis of Chapter 15 Events," Advanced Nuclear Fuels Corporation. (Bases report not approved) (LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)

3.

XN-NF-82-21 (P)(A), 'Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations," Exxon Nuclear Company.

(LCOs 3.2.1, 3.2.2, & 3.2.4)

4.

EMF-84-093(P)(A), 'Steam Line Break Methodology for PWRs,

'Siemens Power Corporation.

(LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)

5.

XN-75-32(P)(A) Supplements 1 through 4, "Computational Procedure for Evaluating Fuel Rod Bowing,' Exxon Nuclear Company. (Bases document not approved)

(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)

Palisades Nuclear Plant 5.0-25 Amendment No. 482,24-7, AMD 220