Technical Requirements Manual Unit 2
ML043370131
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 11/23/2004
From:
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML043370131 (88)


Text

Nov. 23, 2004 Page 1 of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2004-48843 USER INFORMATION: o Name:G H*R M

Address: NUC Phone#: 25 31 TRANS AL INFORMATION:

EMPL#:028401 CA#:0363 TO:

VI 11/23/2004 LOCATION!.US RC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:

TRM2 -

TECHNICAL REQUIREMENTS MANUAL UNIT 2 REMOVE MANUAL TABLE OF CONTENTS DATE: 11/08/2004 ID MANUAL TABLE OF CONTENTS DATE: 11/22/2004 CATEGORY:

DOCUMENTS TYPE: TRM2 ID:

TEXT 2.2 REMOVE:

REV:1 ADD:

REV:

2 CATEGORY: DOCUMENTS TYPE: TRM2 ID:

TEXT 3.2.1 REMOVE:

REV:2 ADD:

REV: 3 CATEGORY:

DOCUMENTS TYPE: TRM2 ID:

TEXT 3.3.9 REMOVE:

REV:0 ADD:

REV: 1 CATEGORY: DOCUMENTS TYPE: TRM2 ID:

TEXT B3.3.9 REMOVE:

REV:0 ADD:

REV:

1 CATEGORY: DOCUMENTS TYPE: TRM2 ID:

TEXT LOES REMOVE:

REV:7 vD:

REV:

8 CATEGORY:

DOCUMENTS TYPE: TRM2 ID:

TEXT TOC REMOVE:

REV:2

,Of   

Nov. 23, 2004 Page2 of 2 ADD:

REV: 3 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY.

FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

SSES,MANUAL Manual Name:

TRM2

'anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 Table Of Contents Issue Date:

  • 11/22/2004 Procedure Name Rev Issue Date Change ID Change Number TRM2 N/A 08/01/2003

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 (07/28/2003)

LbCN 3749 TEXT LOES

Title:

TEXT TOC

Title:

8 11/22/2004 LIST OF EFFECTIVE SECTIONS 3

11/22/2004 TABLE OF CONTENTS TEXT 1.1 0

11/19/2002 e

Title:

USE AND APPLICATION DEFINITIONS TEXT 2.1 0

11/19 2002')

Title:

PLANT PROGRAMS AND SETPOINTS<PLANT,'PROGRAMS TEXT 2.2 2

, 1122/2004

Title:

PLANT PROGRAMS AND SETPOINTS.INSTRUMENT TRIP SETPOINT TABLE TEXT 3.0 It

+0 11/19/2002

Title:

APPLICABIL HNICALREQUIREMENT FOR OPERATION (TRO)

APPLICABILITY TEXT 3.1.1 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI) INSTRUMENTATION TEXT 4.3 0

09/27/2003

Title:

ADMINISTRATIVE CONTROLS SAFETY LIMIT VIOLATION TEXT 3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT 3.1.3 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION Page 1 of 14 Report Date: 11/22/04 Page 1,

of 14 Report Date: 11/22/04

SSES MANUAL I

i Manual Name: TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT 3.2.1 3

11/22/2004

Title:

CORE OPERATING LIMITS CORE OPERATING LIMITS REPORT (COLR)

TEXT 3.3.1

Title:

INSTRUMENTATION TEXT 3.3.2

Title:

INSTRUMENTATION 0

11/19/2002 RADIATION MONITORING INSTRUMENTATION 0

11/19/2002 SEISMIC MONITORING INSTRUMENTATION TEXT 3.3.3 0

11/19/2002

Title:

INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TEXT 3.3.4 0

11/19/2002

Title:

INSTRUMENTATION TRM POST-ACCIDENT MONITORING INSTRUMENTATION TEXT 3.3.5 0

11/19/2002

Title:

INSTRUMENTATION THIS PAGE INTENTIONALLY LEFT BLANK TEXT 3.3.6

Title:

INSTRUMENTATION 1

10/22/2003 TRM ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 0

11/19/2002

Title:

INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3.3.8

Title:

INSTRUMENTATION 1

10/22/2003 TRM RPS INSTRUMENTATION TEXT 3.3.9 1

11/22/2004

Title:

INSTRUMENTATION LPRM UPSCALE ALARM INSTRUMENTATION TEXT 3.3.10 0

11/19/2002

Title:

INSTRUMENTATION REACTOR RECIRCULATION PUMP MG SET STOPS Page 2 of 14 Report Date: 11/22/04 Page 2 of 14 Report Date: 11/22/04

k SSES MANUAL j Manual Namae:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL:UNIT 2 TEXT 3.3.11 1

10/22/2003'

Title:

INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.4.1 0

11/19/2002,

Title:

REACTOR COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY TEXT 3.4.2 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM STRUCTURAL INTEGRITY TEXT 3.4.3

Title:

REACTOR COOLANT 0

11/19/2002 SYSTEM REACTOR COOLANT SYSTEM (RCS)

TEXT 3.4.4 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT TEXT 3.4.5

.t

Title:

REACTOR COOLANT TEXT 3.5.1 0

11/18/2002 SYSTEM REACTOR VESSEL MATERIALS 0

11/19/2002

Title:

ECCS AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 0

11/19/2002

Title:

ECCS AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0

11/19/2002

Title:

ECCS AND RCIC LONG TERM NITROGEN SUPPLY TO ADS TEXT 3.6.1 0

11/19/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3.6.2 0

11/19/2002

Title:

CONTAINMENT SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0

11/19/2002

Title:

CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION Page 3 of 14 Report Date: 11/22/04 Page 3 of 14 Report Date:-11/22/04

I SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.6.4 0

11/19/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1

Title:

PLANT TEXT 3.7.2

Title:

PLANT TEXT 3.7.3.1

Title:

PLANT TEXT 3.7.3.2

Title:

PLANT 0

11/19/2002 SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW)

SHUTDOWN 0

11/19/2002 SYSTEMS ULTIMATE HEAT SINK (UHS)

AND GROUND WATER LEVEL 0

11/19/2002 SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM 0

11/19/2002 SYSTEMS SPRAY AND SPRINKLER SYSTEMS TEXT 3.7.3.3

Title:

PLANT TEXT 3.7.3.4

Title:

PLANT 0

SYSTEMS C02 SYSTEMS 0

SYSTEMS HALON SYSTEMS 11/19/2002 Ix 11/19/2002 TEXT 3.7.3.5

Title:

PLANT TEXT 3.7.3.6

Title:

PLANT TEXT 3.7.3.7

Title:

PLANT TEXT 3.7.3.8

Title:

PLANT TEXT 3.7.4

Title:

PLANT 0

11/19/2002 SYSTEMS FIRE HOSE STATIONS 0

11/19/2002 SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 0

11/19/2002 SYSTEMS FIRE RATED ASSEMBLIES 1

01/12/2004 SYSTEMS FIRE DETECTION INSTRUMENTATION 0

11/19/2002 SYSTEMS SOLID RADWASTE SYSTEM Page 4 of 14 Report Date: 11/22/04 Page 4 of 14 Report Date: 11/22/04

SSES ;MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.7.5.1

Title:

PLANT TEXT 3.7.5.2

Title:

PLANT TEXT 3.7.5.3

Title:

PLANT TEXT 3.7.6

Title:

PLANT TEXT 3.7.7 0

11/19/2002 SYSTEMS MAIN CONDENSER 'OFFGAS HYDROGEN MONITOR 0

11/19/2002 SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE 0

11/19/2002' SYSTEMS LIQUID HOLDUP TANKS' 0

11/19/2002' SYSTEMS ESSW PUMPHOUSE VENTILATION 0

11/19/2002

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS -PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION TEXT 3.7.8 0

11/19/2002 i_11

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 0

11/19/2002'

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT 3.7.10 0

11/19/2002,

Title:

PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)

TEXT 3.8.1 0

11/19/2002

Title:

ELECTRICAL POWER-PRIMARY CONTAINMENT PENETRATION CONDUCTOR-OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 0

11/19/2002

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

CONTINUOUS TEXT 3.8.2.2 1

09/17/2004

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMAL'OVERLOAD PROTECTION-AUTOMATIC TEXT 3.8.3 0

11/19/2002

Title:

ELECTRICAL POWER DIESEL GENERATOR (DG)'MAINTENANCE ACTIVITIES Page 5 of 14 Report Date: 11/22/04 Page 5 of 14 Report Date: 11/22/04

SSES MANUAL

.j Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.8.4 0

11/19/2002

Title:

ELECTRICAL POWER 24 VDC ELECTRICAL SUBSYSTEM TEXT 3.8.5 0

11/19/2002

Title:

ELECTRICAL POWER DEGRADED VOLTAGE PROTECTION TEXT 3.8.6 0

11/19/2002

Title:

ELECTRICAL POWER EMERGENCY SWITCHGEAR ROOM COOLING TEXT 3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS COMMUNICATIONS.

TEXT 3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.1 0

11/19/2002

Title:

MISCELLANEOUS SEALED SOURCE CONTAMINATION TEXT 3.10.2 0

11/19/2002

Title:

MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 0

11/19/2002

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.10.4 0

11/19/2002

Title:

MISCELLANEOUS LEADING EDGE FLOW METER (LEFM)

TEXT 3.11.1.1 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS CONCENTRATION TEXT 3.11.1.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS DOSE Page 6 of 14 Report Date: 11/22/04 Page 6 of 14 Report Date: 11/22/64

SSES MUANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.11.1.3

Title:

RADIOACTIVE TEXT 3.11.1.4

Title:

RADIOACTIVE TEXT 3.11.4.2

Title:

RADIOACTIVE TEXT 3.11.4.3

Title:

RADIOACTIVE 0

11/19/2002 LIQUID WASTE TREATMENT SYSTEM EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 0

11/19/2002 ',.

LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION 0

11/19/2002-

LAND USE CENSUS '

0 11/19/2002 INTERLABORATORY COMPARISON PROGRAM TEXT 3.12.1 0

11/19/2002

Title:

LOADS CONTROL PROGRAM CRANE-TRAVEL-SPENT FUEL STORAGE POOL TEXT 3.12.2 0

11/19/2002 '

_/'

Title:

LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM LIGHT LOADS'REQUIREMENTS TEXT B3.0 0

11/19/2002 ',

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT-FOR'OPERATION (TRO)

TEXT B3.1.1 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES-,ANTICIPATED TRANSIENT WITHOUT ROD INJECTION (ATWS-ARI) INSTRUMENTATION APPLICABILITY SCRAM ALTERNATE TEXT B3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD DRIVE (CRD) HOUSING SUPPORT TEXT B3.1.3 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD SCRAM ACCUMULATORS-INSTRUMENTATION AND CHECK VALVE Page 7 of 14 Report Date: 11/22/04 Page 7 of 14 Report Date: 11/22/04

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.2.1

Title:

CORE OPERATING L TEXT B3.3.1

Title:

INSTRUMENTATION TEXT B3.3.2

Title:

INSTRUMENTATION TEXT B3.3.3

Title:

INSTRUMENTATION TEXT B3.3.4

Title:

INSTRUMENTATION TEXT B3.3.5

Title:

INSTRUMENTATION TEXT B3.3.6

Title:

INSTRUMENTATION TEXT B3.3.7

Title:

INSTRUMENTATION TEXT B3.3.8

Title:

INSTRUMENTATION TEXT B3.3.9

Title:

INSTRUMENTATION TEXT B3.3.10

Title:

INSTRUMENTATION TEXT B3.3.11

,IMITS 0

11/19/2002 BASES CORE OPERATING LIMITS REPORT (COLR) 0 11/19/2002 BASES RADIATION MONITORING INSTRUMENTATION 0

11/19/2002 BASES SEISMIC MONITORING INSTRUMENTATION 0

11/19/2002 BASES METEOROLOGICAL MONITORING INSTRUMENTATION 0

11/19/2002 BASES TRM POST ACCIDENT MONITORING (PAM) INSTRUMENTATION 0

11/19/2002 BASES THIS PAGE INTENTIONALLY LEFT BLANK 1

10/22/2003 BASES TRM ISOLATION ACTUATION INSTRUMENTATION 0

11/19/2002 BASES MAIN TURBINE OVERSPEED PROTECTION SYSTEM 1

10/22/2003 BASES TRM RPS INSTRUMENTATION 1

11/22/2004 BASES LPRM UPSCALE ALARM INSTRUMENTATION 0

11/19/2002 BASES REACTOR RECIRCULATION PUMP MG SET STOPS 1

10/22/2003

Title:

INSTRUMENTATION BASES MVP ISOLATION INSTRUMENTATION Page B of 14 Report Date: 11/22/04 Page 8 of 14 Report Date: 11/22/04

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.4.1 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY TEXT B3.4.2 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES 'STRUCTURAL INTEGRITY TEXT B3.4.3 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR TEXT B3.4.4 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR-RECIRCULATION FLOW AND ROD LINE LIMIT TEXT B3.4.5 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR VESSEL MATERIALS TEXT B3.5.1 0

11/19/2002 K>

Title:

ECCS AND RCIC BASES ADS MANUAL INHIBIT TEXT B3.5.2 0

11/19/2002

Title:

ECCS AND RCIC BASES ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION--

TEXT B3.5.3 0

11/19/2002

Title:

ECCS AND RCIC.BASES.LONG TERM NITROGEN SUPPLY TO ADS.

TEXT B3.6.1 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0

11/19i2002

Title:

CONTAINMENT BASES SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION' INDICATION TEXT B3.6.3 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 0

11/19/2002

Title:

CONTAINMENT BASES PRIMARY-CONTAINMENT CLOSED SYSTEM BOUNDARIES Page 9 of 14 Report Date: 11/22/04 Page 9 of 14 Report Date: 11/22/04

l

-w SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.7.1

Title:

PLANT SYSTEMS TEXT B3.7.2

Title:

PLANT SYSTEMS TEXT B3.7.3.1

Title:

PLANT SYSTEMS TEXT B3.7.3.2

Title:

PLANT SYSTEMS TEXT B3.7.3.3

Title:

PLANT SYSTEMS TEXT B3.7.3.4

Title:

PLANT SYSTEMS TEXT B3.7.3.5

Title:

PLANT SYSTEMS TEXT B3.7.3.6

Title:

PLANT SYSTEMS TEXT B3.7.3.7

Title:

PLANT SYSTEMS TEXT B3.7.3.8

Title:

PLANT SYSTEMS TEXT B3.7.4

Title:

PLANT SYSTEMS TEXT B3.7.5.1

Title:

PLANT SYSTEMS 0

11/19/2002 BASES EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN) 0 11/19/2002 BASES ULTIMATE HEAT SINK (UHS) GROUND WATER LEVEL 0

11/19/2002 BASES FIRE SUPPRESSION WATER SUPPLY SYSTEM 0

11/19/2002 BASES SPRAY AND SPRINKLER SYSTEMS 0

11/19/2002 BASES C02 SYSTEMS 0

11/19/2002 BASES HALON SYSTEMS 0

11/19/2002 BASES FIRE HOSE STATIONS.

0 11/19/2002 BASES YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 0

11/19/2002 BASES FIRE RATED ASSEMBLIES 1

01/12/2004 BASES FIRE DETECTION INSTRUMENTATION 0

11/19/2002 BASES SOLID RADWASTE SYSTEM 0

11/19/2002 BASES MAIN CONDENSER OFFGAS HYDROGEN MONITOR Page 10 of 14 Report Date: 11/22/04 Page 10 of 14 Report Date: 11/22/04

SSES MANUAL

? Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.7.5.2

Title:

PLANT SYSTEMS

.TEXT B3.7.5.3

Title:

PLANT SYSTEMS TEXT B3.7.6

Title:

PLANT SYSTEMS TEXT B3.7.7 0

11/19/2002 BASES MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE 0

11/19/2002' BASES LIQUID HOLDUP TANKS 0

11/19/2002 l

BASES ESSW PUMPHOUSE VENTILATION 0

11/19/2002

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION TEXT B3.7.8 0

11/19/2002.

Title:

PLANT SYSTEMS BASES SNUBBERS TEXT B3.7.9 0

11/19/2002'

\\X,}

Title:

PLANT SYSTEMS BASES CONTROL STRUCTURE HVAC TEXT B3.7.10 0

11/19/2002

Title:

PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS TEXT B3.8.1

Title:

ELECTRICAL PROTECTIVE TEXT B3.8.2.1

Title:

ELECTRICAL CONTINUOUS TEXT B3.8.2.2

Title:

ELECTRICAL AUTOMATIC TEXT B3.8.3

Title:

ELECTRICAL TEXT B3.8.4

Title:

ELECTRICAL 0

11/19/2002 POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES 0

11/19/2002 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

1 09/17/2004' POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

0 11/19/2002 POWER BASES DIESEL GENERATOR (DG)

MAINTENANCE ACTIVITIES 0

11/19/2002 POWER BASES 24 VDC -ELECTRICAL POWER SUBSYSTEM Pae1lf1 eotDt:1/20 Page 11 of 14 Report Date: 11/22/04

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.8.5 0

11/19/2002

Title:

ELECTRICAL POWER BASES DEGRADED VOLTAGE PROTECTION TEXT B3.8.6 0

11/19/2002

Title:

ELECTRICAL POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING TEXT B3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS BASES DECAY TIME TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COMMUNICATIONS TEXT B3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM TEXT B3.10.1 0

11/19/2002

Title:

MISCELLANEOUS BASES SEALED SOURCE CONTAMINATION TEXT B3.10.2 0

11/19/2002

Title:

MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT B3.10.3 0

11/19/2002

Title:

MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT B3.10.4 0

11/19/2002

Title:

MISCELLANEOUS BASES LEADING EDGE FLOW METER (LEFM)

TEXT B3.11.1.1 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS CONCENTRATION TEXT B3.11.1.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS DOSE TEXT B3.11.1.3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID WASTE TREATMENT SYSTEM Pae1 f1 eotDt:1/20 Page 12 of 14 Report Date: 11/22/04

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.11.1.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID RADWASTE'EFFLUENT MONITORING INSTRUMENTATION TEXT B3.11.1.5

Title:

RADIOACTIVE EFFLUENTS INSTRUMENTATION 0

BASES 11/19/2002 '

RADIOACTIVE LIQUID PROCESS MONITORING TEXT B3.11.2.1 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE RATE TEXT B3.11.2.2

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.3

Title:

RADIOACTIVE EFFLUENTS PARTICULATES FORM TEXT B3.11.2.4

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.5

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.6

Title:

RADIOACTIVE EFFLUENTS INSTRUMENTATION TEXT B3.11.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.1

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.2

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.3

Title:

RADIOACTIVE EFFLUENTS 0

11/19/2002 BASES DOSE -

NOBLE GASES 0

11/19/2002' BASES DOSE -

IODINE, TRITIUM, AND RADIONUCLIDES IN '

0 11/19/2002 BASES GASEOUS RADWASTE TREATMENT SYSTEM 2

10/27/2004 BASES VENTILATION EXHAUST TREATMENT SYSTEM 1

01/27/2004 BASES RADIOACTIVE GASEOUS EFFLUENT MONITORING LDCN 3614 0

11/19/2002' BASES TOTAL DOSE 0

11/19/2002 BASES MONITORING PROGRAM 0

11/19/2002 BASES LAND USE CENSUS 0

11/19/2002 BASES INTERLABORATORY COMPARISON PROGRAM Page13 f 14Reprt ate:11/2/0 Page 13 of 24 Report Date: 11/22/04

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 II A

TEXT B3.12.1

Title:

LOADS CONTROL TEXT B3.12.2

Title:

LOADS CONTROL TEXT B3.12.3

Title:

LOADS CONTROL TEXT 3.11.2.1

Title:

RADIOACTIVE El TEXT 3.11.2.6

Title:

RADIOACTIVE El 0

11/19/2002 PROGRAM BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL 0

11/19/2002 PROGRAM BASES HEAVY LOADS REQUIREMENTS 0

11/19/2002 PROGRAM BASES LIGHT LOADS REQUIREMENTS 1

01/27/2004 PFLUENTS DOSE RATE 1

01/27/2004

?FLUENTS RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION LDCN 3614 0

09/27/2003 TEXT 4.1

Title:

ADMINISTRATIVE CONTROLS ORGANIZATION TEXT 4.2

Title:

TEXT 4.4

Title:

TEXT 4.5

Title:

TEXT 4.6

Title:

TEXT 4.7

Title:

ADMINISTRATIVE CONTROLS 0

ADMINISTRATIVE CONTROLS 0

ADMINISTRATIVE CONTROLS 0

ADMINISTRATIVE CONTROLS 0

ADMINISTRATIVE CONTROLS 09/27/2003 REPORTABLE EVENT ACTION 09/27/2003 PROCEDURES & PROGRAMS 09/27/2003 REPORTING REQUIREMENTS 09/27/2003 RADIATION PROTECTION PROGRAM 09/27/2003 TRAINING Page 14 of 14 Report Date: 11/22/04 Page 14 of 14 Report Date: 11/22/04

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 8 UST OF EFFECTVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date TOC 1.0 2.0 3.0 3.1 3.2 3.3 TABLE OF CONTENTS USE AND APPLICATION Page TRM / 1.0-1 Page TRM / 1.0-2 Page TRM / 1.0-3 PLANT PROGRAMS Page 2.0-1 Pages TRM / 2.0-2 through TRM / 2.0-4 Page TRM / 2.0-5 Pages TRM / 2.0-6 through TRM / 2.0-14 APPLICABILITY Pages TRM / 3.0-1 and TRM /3.0-2 Page TRM / 3.0-3 Page TRM / 3.0-4 REACTIVITY CONTROL SYSTEMS".

Pages 3.1-1 through 3.1-6 '!

Pages TRM / 3.1-7 and TRMrI 3,1-8 J Pages TRM / 3.1-9 and,

31-9a Page TRM / 3.1-10 CORE OPERATING LIMITS REPORT Page 3.2-1 i

K>

Pages TRM ;/3.2-2 through TRM / 3.2-38 INSTRUMENTATION Pages TRM/3.3-1 through TRM / 3.3-3 PageTRMI/ 3'3-4

/leags' 3:3-5 through 3.3-8 Pages TRM / 3.3-9 and TRM / 3.3-9a Rages

'TRM / 3.3-10 and TRM / 3.3-11 Page TRM /3.3-12 Pages TRM / 3.3-13 and TRM / 3.3-14 Page TRM / 3.3-15 Page TRM / 3.3-16 Pages TRM / 3.3-17 and TRM /3.3-18 Pages TRM / 3.3-19 and TRM / 3.3-20 Page TRM / 3.3-21 Pages TRM /3.3.-21 a through TRM / 3.3-21 d Pages TRM / 3.3-22 through TRM / 3.3-24 Page TRM / 3.3-25 11/15/2004 08/31/1998 10/04/2002 08/31/1998 08/31/1998 06/25/2002 04/12/1999 11/12/2004 04/08/1999 03/15/2002 04/08/1999 08/31/1998

-06/05/2002 02/18/1999 02/18/1999 08/31/1998 11/12/2004 07/16/1999 11/28/2000 08/31/1998 12/17/1998 12/17/1998 03/30/2001 12/14/1998 10/22/2003 06/27/2001 06/14/2002 10/22/2003 11/12/2004 11/12/2004 05/16/2003 10/22/2003 I

I I

I SUSQUEHANNA - UNIT 2

.TRM / LOES-1 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 8 UST.OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.4 REACTOR COOLANT SYSTEM Pages 3.4-1 through 3.4-5 Pages 3.4-6 through 3.4-13 3.5 EMERGENCY CORE COOLING AND RCIC Pages 3.5-1 through 3.5-3 Page TRM / 3.5-4 Pages 3.5-5 through 3.5-7 :

10/23/1998 08/31/1998 08/31/1998 04/17/2000 08/31/1998 3.6 CONTAINMENT Pages 3.6-1 through 3.6-4 Page TRM / 3.6-5 Page 3.6-6 Pages TRM / 3.6-7 through TRM / 3.6-9 08/31/1998 01/07/2002 08/31/1998 12/31/2002 3.7 PLANT SYSTEMS Pages TRM / 3.7-1 and TRM / 3.7-2 Page 3.7-3 Pages TRM / 3.7-4 through TRM / 3.7-10 Page TRM / 3.7-11 Pages TRM / 3.7-12 through TRM / 3.7-27 Pages TRM / 3.7-28 through TRM / 3.7-31 Page TRM / 3.7-32 Page TRM / 3.7-33 Pages TRM / 3.7-34 through TRM / 3.7-36 Pages 3.7-37 through 3.7-39 Pages TRM / 3.7-40 and TRM I 3.7-40a Pages 3.7-41 and 3.7-42 Pages 3.7-43 through 3.7-47 Page TRM / 3.7-48 Pages TRM / 3.7-49 and TRM / 3.7-50 Pages TRM / 3.7-51 and TRM /3.7-52 Page TRM / 3.7-53 07/29/1999 08/31/1998 08/02/1999 01/21/2000 08/02/1999 11/16/2001 01/09/2004 10/05/2002 02/01/1999 08/31/1998 08/11/2000 08/31/1998 10/13/1998 03/08/2003 03/09/2001 04/15/2003 07/29/1999 3.8 ELECTRICAL POWER Pages TRM / 3.8-1 and TRM / 3.8-2 Page 3.8-3 Page TRM / 3.8-4 Pages TRM / 3.8-5 and TRM / 3.8-6 Pages TRM / 3.8-7 through TRM / 3.8-8 Page TRM / 3.8-9

.Page 3.8-10 Page TRM /3.8-11 Pages 3.8-12 through 3.8-14 04/02/2002 08/31/1998 12/31/2002 04/02/2002 08/31/1998 08/24/2001 08/31/1998 08/10/2004 08/31/1998 SUSQUEHANNA - UNIT 2 TRM / LOES-2 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 8 LIST OF EFFECTIVE SECT7ONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Pages TRM / 3.8-15 through TRM / 3.8-17 Page 3.8-18 Page TRM / 3.8-19 Page TRM / 3.8-20 Pages TRM / 3.8-21 through TRM I 3.8-23 Pages 3.8-24 and 3.8-25.

04/02/2002 02/01/1999 04/02/2002 02/01/1999 06/06/1999 08/31/1998 08/31/1998 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-3 3.10 MISCELLANEOUS Pages 3.10-1 through 3.10-4 Page TRM / 3.10-5 Page TRM / 3.10-6 Page TRM / 3.10-7 08/30/1998 03/08/2003 06/05/2002 04/07/2000 Corrected 04/17/2002 Page TRM / 3.10-8 3.11 3.12 RADIOACTIVE EFFLUENTS Pages 3.11 -1 through 3.11-12 Pages 3.11-13 through 3.11-16 Pages 3.11-17 and 3.11-18 Page TRM / 3.11-19 Pages 3.11-20 and 3.1.1-21 Pages TRM /3.11-22 through TRM /3.11-24 Page 3.11-25 Pages TRM / 3.11-26 through TRM / 3.11-32.

Pages 3.11-33 through 3.11-47 LOADS CONTROL PROGRAM Pages TRM / 3.12-1 through TRM / 3.12-5 08i31/1998 09/01/1998 08/31/1998 01/2112004 08/31/1998 04/02/2002 09/01/1998 01/2112004 08/31/1998 02/05/1999 4.0 ADMINISTRATIVE CONTROLS Pages 4.0-1 through 4.0-8 08/31/1998 SUSQUEHANNA - UNIT 2 TRM / LOES-3 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 8 USTOFEFFECTIVESECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date B 3.0 B3.1 B 3.2 APPLICABILITY BASES Pages B 3.0-1 through B 3.0-10 Pages TRM / B 3.0-11 through TRM I B 3.0-15 REACTIVITY CONTROL SYSTEMS BASES Pages TRM I B 3.1-1 through TRM / B 3.1-3 Page B 3.1-4 Pages TRM / B 3.1-5 through TRM /IB 3.1-7 Page TRM I B 3.1-8 CORE OPERATING LIMITS BASES Page B 3.2-1 08/31/1998 03/15/2002 07/13/1999 08/31/1998 07/13/1999 02/18/1999 08131/1998 B 3.3 INSTRUMENTATION BASES Page TRM/B 3.3-1 Page B 3.3-2 Pages TRM l B 3.3-3 and TRM I B 3.3-3A Pages TRM I B 3.3-4 through TRM I B 3.3-6 Pages TRM / B 3.3-7 through TRM / B 3.3-9 Pages B 3.3-10 through B 3.3-12 Page TRM / B3.3-13 Page TRM I B 3.3-14 Page TRM / B 3.3-14a Page TRM I B 3.3-14b Page TRM / B 3.3-15 Page TRM / B 3.3-16 Page TRM / B 3.3-17 Pages TRM / B 3.3-18 and TRM B 3.3-19 Pages TRM / B 3.3:19a through TRM / B 3.3.19e Pages TRM / B 3.3-20 and TRM I B 3.3-21 Page TRM / B3.3-22 Page TRM / B3.3-23 B 3.4 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 through B 3.4-4 Page TRM I B 3.4-5 Page B 3.4-6 B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 through B 3.5-5 B 3.6 CONTAINMENT BASES Page TRM / B 3.6-1 Page TRM / B 3.6-2 Page B 3.6-3 04/07/2000 08/31/1998 12/29/2000 03/21/2003 03/30/2001 08/31/1998 10/22/2003 06/25/2002 06/14/2002 06/14/2002 10/22/2003 10/22/2003 10/22/2003 11/12/2004 11/12/2004 05/16/2003 10/22/2003 05/16/2003 08/31/1998 10/15/1999 08/31/1998 08/31/1998 07/26/2001 02/01/1999 08/31/1998 I

SUSQUEHANNA - UNIT 2 TRM/LOES4 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 8 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

"il Section Title Effective Date Page TRM / B 3.6-4 Page TRM / B 3.6-5 Pages TRM / B 3.6-6 through TRM / B 3.6-11 B 3.7 B 3.8 B.3.9 PLANT SYSTEMS BASES Pages B 3.7-1 and B 3.7-2 Pages TRM / B 3.7-3 through TRM / B 3.7-7 Page TRM / B 3.7-7a Pages TRM / B 3.7-8 through TRM / B 3.7-10 Page TRM / B 3.7-10a Pages TRM / B 3.7-11 through TRM / B 3.7-14 Page TRM / B 3.7-14a and TRM / B 3.7-14b Pages TRM / B 3.7-15 and TRM / B 3.7-16 Pages B 3.7-17 through B 3.7-20 Pages TRM I B 3.7-21 through TRM/B 3.7-21a Pages TRM/B 3.7-22 and TRM/B 3.7-23 Pages B 3.7-24 through B 3.7-30 Pages TRM / B 3.7-31 and TRM I B 3.7-32 Page TRM i B 3.7-33 Pages TRM / B 3.7-34 and TRM / B 3.7-35 ELECTRICAL POWER BASES Pages TRM / B 3.8-1 and TRM I B 3.8-2 Page TRM / B 3.8-2a Page TRM / B 3.8-3 Page TRM / B 3.8-3a Page TRM I B 3.8-4 Page TRM / B 3.8-4a Page TRM / B 3.8-5 Pages TRM / B 3.8-6 through TRM I B 3.8-17 REFUELING OPERATIONS BASES Pages B 3.9-1 and B 3.9-2 Pages B 3.9-3 through B 3.9-7 09/23/1999 01/07/2002 12/31/2002 08/31/1998 08/02/1999 08/02/1999 08/02/1999 08/02/1999 08/02/1999 01/09/2004 02/01/1999 08/31/1998 05/11/2001 04/07/2000 08/31/1998 03/09/2001 04/15/2003 07/05/2000 04/02/2002 04/02/2002

  • 04/02/2002 04/02/2002 04/02/2002 08/10/2004 08/31/1998 04/02/2002 08/31/1998 10/23/1998 B 3.10 MISCELLANEOUS BASES Pages B 3.10-1 through B 3.10-2 Page TRM / B 3.10-3 Pages TRM / B 3.10-4 and TRM / B 3.10-5 Pages TRM / B 3.10-6 and TRM / 3.10-7 08/31/1998 03/08/2003 08/23/1999 04/17/2002 B 3.11 RADIOACTIVE EFFLUENTS BASES

. Pages B 3.11-1 through B 3.11-9 PagesTRM/B3.11-10 08/31/1998 02/01/1999 SUSQUEHANNA - UNIT 2 TRM / LOES-5 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 8 UST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Pages TRM/B 3.11-11 and TRM/B 3.11-1 Ia Pages TRM/B 3.11-12 and TRM/B 3.11-13 Page TRM / B 3.11-14 Page TRM / B 3.11-15 Pages B 3.11-16 through B 3.11-19 Page TRM / B 3.11-20 Page TRM / B 3.11-20a Page TRM / B 3.11-21 Page TRM I B 3.11-22 Page TRM B 3.11.23 Page TRM /B 3.11-23a Pages TRM / B 3.11-24 and TRM / B 3.11-25 Pages B 3.11-26 through B 3.11-35 Page TRM / B 3.11-36 B.3.12 LOADS CONTROL PROGRAM BASES Pages TRM / B 3.12-1 through TRM / B 3.12-3 04/07/2000 02/01/1999 11/01/1999 02/01/1999 08/31/1998 04/02/2002 04/02/2002 10/15/2004 10/15/2004 04/02/2002 04/02/2002 01/21/2004 08/31/1998 02/12/1999 02105/1999 TRM2 text LOES.doc 11/11/04 SUSQUEHANNA - UNIT 2 TRM / LOES-6 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 3 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)

SECTION TITLE PAGE 1.0 USE AND APPLICATION....................................

1.0-1 1.1 Definitions..............

TRM/1.0-2 2.0 PLANT PROGRAMS..............

2.0-1 2.1 Plant Programs......................................................................................2.01 2.2 Instrument Trip Setpoint Table...............

.................... TRM/2.0-5 3.0 APPLICABILITY...................................

TRM3.0-1 3.0 (TRO) - TR for Operation (TRO) Applicability............................... TRM/3.0-1 3.0 (TRS) - TR Surveillance (TRS) Applicability.................................. TRM3.0-3 3.1 REACTIVITY CONTROL SYSTEMS..................................

3.1-1 3.1.1 Alternate Rod Injection...............

3.1-1 3.1.2 CRD Housing Support.3.1-4 3.1.3 Control Rod Block Instrumentation........................

3.1-5 3.1.4 Control Rod Scram Accumulators Instrumentation and Check Valve......................................

TRM/3.1-9 3.2 CORE OPERATING LIMITS REPORT....................................

3.2-1 3.2.1 Core Operating Limits Report....................................

3.2-1 3.3 INSTRUMENTATION....................................

TRM/3.3-1

,3.3.1 Radiation Monitoring Instrumentation...................................... TRM/3.3-1 3.3.2 Seismic Monitoring Instrumentation....................................

TRM/3.3-4 3.3.3 Meteorological Monitoring Instrumentation....................................

3.3-7 3.3.4 TRM Post-Accident Monitoring Instrumentation............................. TRM/3.3-9 3.3.5 Section Not Used.................................

TRM/3.3-12 3.3.6 TRM Containment Isolation Instrumentatidn................................. TRM/3:3-13 3.3.7 Turbine Overspeed Protection System.................................

TRM/3.3-17 3.3.8 Section Not Used..................................

TRM/3.3-19 3.3.9 OPRM Instrumentation.

................................. TRM/3.3-21 3.3.10 Reactor Recirculation Pump MG Set Electrical and Mechanical Stops...........................

TRM/3.3-22 3.3.11 MVP Isolation Instrumentation...........................

TRM/3.3-24 3.4 REACTOR COOLANT SYSTEM..........................

3.4-1 3.4.1 Reactor Coolant System Chemistry.........................

3A4-1 3.4.2 Structural Integrity........................

3.4-6 3.4.3 High/Low Pressure Interface Leakage Monitors........................................ 3.4-9 3.4.4 Reactor Recirculation Flow and Rod Line Limit...................................... 3.4-12 3.4.5 Reactor Vessel Material Surveillances Program.3.4-13 3.5 EMERGENCY CORE COOLING AND RCIC.3.5-1 3.5.1 ADS Manual Inhibit.3.5-1 3.5.2 ECCS and RCIC System Monitoring Instrumentation.3.5-3 SUSQEHANA UNI 2 RM/OC-1EFFCTIE DAE 1/15200 SUSQUEHANNA - UNIT 2 TRM / TOC-1 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 3 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)

SECTION TITLE PAGE 3.5.3 Long Term Nitrogen Supply to ADS.........................................

3.5-6 3.6 CONTAINMENT...........................

3.6-1 3.6.1 VENTING or PURGING........................................6.................................3. 1

.3.6.2 Suppression Chamber-to-Drywell Vacuum Breaker Position Indication.

3.6-3 3.6.3 Suppression Pool Alarm Instrumentation......................................

3.6-4 3.6.4 Primary Containment Closed System Boundaries........................ TRM/3.6-7 3.7 PLANT SYSTEMS.

TRM/3.7-1 3.7.1 Emergency Service Water System (Shutdown)............................ TRM/3.7-1 3.7.2 Ultimate Heat Sink and Ground Water Level......................................

3.7-3 3.7.3.1 Fire Suppression Water Supply System...................................... TRM/3.7-4 3.7.3.2 Spray and Sprinkler Systems........................................ TRM/3.7-8 3.7.3.3 C02 systems........................................

TRM/3.7-12 3.7.3.4 Halon Systems........................................

TRM/3.7-16 3.7.3.5 Fire Hose Stations...................................... TRM/3.7-18 3.7.3.6 Yard Fire Hydrants and Hydrant Hose Houses............................. TRM/3.7-22 3.7.3.7 Fire Rated Assemblies......................................

TRM/3.7-24 3.7.3.8 Fire Detection Instrumentation......................................

TRM/3.7-26 3.7.4 Solid Radwaste System..............................

TRM/3.7-35 3.7.5.1 Main Condenser Offgas Hydrogen Monitor..............................

3.7-38 3.7.5.2 Main Condenser Explosive Gas Mixture..............................

3.7-39 3.7.5.3 Liquid Holdup Tanks...............................

TRM/3.7-40 3.7.6 ESSW Pumphouse Ventilation..............................

3.7-41 3.7.7 Main Condenser Offgas Pretreatment Logarithmic Radiation Monitoring Instrumentation.....................

3.7-42 3.7.8 Snubbers.3.7-44 3.7.9 Control Structure HVAC..................

TRM/3.7-50 3.7.10 Spent Fuel Storage Pools (SFSPs).T...................-

TRM/3.7-51 3.8 ELECTRICAL POWER.........................................

TRM/3.8-1 3.8.1 Primary Containment Penetration Conductor Overcurrent Protective Devices.......

TRM13.8-i 3.8.2.1 Motor Operated Valves Thermal Overload Protection -

Continuous.......

TRM/3.8-5 3.8.2.2 Motor Operated Valves Thermal Overload Protection -

Automatic.......

TRM/3.8-1 1 3.8.3 Diesel Generator (DG) Maintanence Activities.......

3.8-13 3.8.4 24VDC Electrical Power Subsystem.........................

TRM/3.8-15 3.8.5 Degraded Voltage Protection........................

.... TRM/3.8-21 3.8.6 Emergency Switchgear Room Cooling.

3.8-24 3.9 R

F E

I G O E

A I

.. 'r..................................................7..................... 3.9 1

3.9 REFUELING OPERATIONS.........

3.9-1 3.9.1 Decay Time.

3.9-1 3.9.2 Communications.3.9-2 SUSQUEHANNA -

UNIT 2 TRM I TOC-2 EFFECTIVE DATE 11/15/2004 SUSQUEHANNA - UNIT 2 TRM / TOC-2 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 3 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)

SECTION TITLE PAGE 3.9.3 Refueling Platform..........................................

3.9-3 3.10 MISCELLANEOUS.....................................................................................3.10-1 3.10.1 Sealed Source Contamination...............................................................3.10-1 3.10.2 MODE 5 Shutdown Margin Test RPS Instrumentation..........................3.14 3.10.3 Independent Spent Fuel Storage Installation (ISFSI).................... TRM/3.10-7 3.10.4 Leading Edge Flow Meter (LEFM)..........................................

TRM/3.10-8 3.11 RADIOACTIVE EFFLUENTS..........................................

3.11-1 3.11.1 Liquid Effluents......................

3.11-1 3.11.1.1 Liquid Effluents Concentration......................

3.11-1 3.11.1.2 Liquid Effluents Dose..........

........ 3.11-4 3.11.1.3 Liquid Waste Treatment System......................

3.11-6

.3.11.1.4 Liquid Radwaste Effluent Monitoring Instrumentation............................ 3.11-8 3.11.1.5 Radioactive Liquid Process Monitoring Instrumentation........................ 3.11-13 3.11.2 Gaseous Effluents.......................................

3.11-17 3.11.2.1 Dose Rate.............

3.11-17 3.11.2.2 Dose - Noble Gases...........

...... 3.11-20 3.11.2.3 Dose - Iodine, Tritium, and Radionuclides in Particulate Form...........................

3.11-21 3.11.2.4 Gaseous Radwaste Treatment System...........................

TRM/3.11-22 3.11.2.5 Ventilation Exhaust Treatment System...........................

TRM/3.11-23 3.11.2.6 Radioactive Gaseous Effluent Monitoring Instrumentation.

.......... 3.11-26 3.11.3 Total Dose..........

3.11-33 3.11.4 Radiological Environmental Monitoring......

3.11-35 3.11.4.1 Monitoring Program..........................

3.11-35 3.11.4.2 Land Use Census.3.11-45 3.11.4.3 Interlaboratory Comparison Program.3.11-47 3.12 LOADS CONTROL PROGRAM...............................

TRM/3.12-1 3.12.1 Crane Travel - Spent Fuel Storage Pool...............................

TRM/3.12-1 3.12.2 Heavy Loads Requirements................................. TRM/3.12.3 3.12.3 Light Loads Requirements...............................

TRM/3.12-5 4.0 ADMINISTRATIVE CONTROLS..................................................................4.0-1 4.1 Organization..........................................................................................04.-1 4.2 Reportable Event Action..............................................................4.........4.02 4.3 Safety Limit Violation.............................................................................4.03 4.4 Procedures and Programs..........................................4........................:..4.4 4.5 Reporting Requirements..........................................................4.............4.-5 4.6 Radiation Protection Program................................................................4.0-7 4.7.

Training................

4.0-8 SUSQUEHANNA -

UNIT 2 TRM /TOC-3 EFFECTIVE DATE 11/15/2004 SUSQUEHANNA - UNIT 2 TRM / TOCG3 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)

PPL Rev. 3 SECTION B 3.0 B 3.0 B 3.1.1 B 3.1.2 B 3.1.3 B 3.1.4 B 3.2.1 B 3.3.1 B 3.3.2 B 3.3.3 B 3.3.4 B 3.3.5 B 3.3.6 B 3.3.7 B 3.3.8 B 3.3.9 B 3.3.10 B3.3.11 B 3.4.1 B 3.4.2 B 3.4.3 B 3.4.4 B 3.4.5 B 3.5.1 B 3.5.2 B 3.5.3 B 3.6.1 B 3.6.2 B 3.6.3 B 3.6.4 B 3.7.1 B 3.7.2 B 3.7.3.1 B 3.7.3.2 B 3.7.3.3 B 3.7.3.4 TITLE PAGE (TRO) - TR for Operation (TRO) Applicability.................................... B 3.0-1 (TRS) - TR Surveillance (TRS) Applicability.....................

.............. B 3.0-9 Alternate Rod Injection...................................

TRM/B 3.1-1 CRD Housing Support...................................

B 3.1-4 Control Rod Block Instrumentation...................................

TRM/B 3.1-5 Control Rod Scram Accumulators Instrumentation and Check Valve...........

TRM/B 3.1-8 Core Operating Limits Report (COLR)....................................

B 3.2-1 Radiation Monitoring Instrumentation....................................

TRM/B 3.3-1 Seismic Monitoring Instrumentation....................................

B 3.3-2 Meteorological Monitoring Instrumentation.................................. TRM/B 3.3-3 TRM Post-Accident Monitoring Instrumentation........................... TRM/B 3.3-4 Section Not Used....................................

TRM/B 3.3-7 TRM Containment Isolation Instrumentation....................................

B 3.3-10 Turbine Overspeed Protection System....................................

TRM/B 3.3-14 Section Not Used....................................

TRM/B 3.3-15 OPRM Instrumentation....................................

TRM/B 3.3-18 Reactor Recirculation Pump MG Set Electrical and Mechanical Stops...........

TRMIB 3.3-20 MVP Isolation Instrumentation....................

TRMlB 3.3-22 Reactor Coolant System Chemistry..................................

B 3.4-1 Structural Integrity

................................. B 3.4-2 High/Low Pressure Interface Leakage Monitors................................. B 3.4-4 Reactor Recirculation Flow and Rod Line Limit............................ TRM/B 3.4-5 Reactor Vessel Material Surveillances Program.B 3.4-6 ADS Manual Inhibit............

B 3.5-1 ECCS and RCIC System Monitoring Instrumentation

....... B 3.5-3 Long Term Nitrogen Supply to ADS.......

B 3.5-4 VENTING or PURGING.......

TRM/B 3.6-1 Suppression Chamber-to-Drywell Vacuum Breaker Position Indication.......

B 3.6-3 Suppression Pool Alarm Instrumentation.......

B 3.6-4 Primary Containment Closed System Boundaries.......

TRM/B 3.6-6 Emergency Service Water System (Shutdown).

B 3.7-1 Ultimate Heat Sink and Ground Water Level.B 3.7-2 Fire Suppression Water Supply System.TRM/B 3.7-3 Spray and Sprinkler Systems.TRM/B 3.7-5 C02 systems.TRM/B 3.7-7 Halon Systems./

TRB 3.7-8 I

SUSQUEHANNA - UNIT 2 TRM / TOC-4 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)

PPL Rev. 3 SECTION B 3.7.3.5 B 3.7.3.6 B 3.7.3.7 B 3.7.3.8 B 3.7.4 B 3.7.5.1 B 3.7.5.2 B 3.7.5.3 B 3.7.6 B 3.7.7 B 3.7.8 B 3.7.9 B 3.7.10 TITLE PAGE Fire Hose Stations................................

TRM/B 3.7-10 Yard Fire Hydrants and Hydrant Hose Houses............... U............

TRM/B 3.7-11 Fire Rated Assemblies................................

TRM/B 3.7-12 Fire Detection Instrumentation................................

TRM/B 3.7-14 Solid Radwaste System..............

......... TRM/B 3.7-15 Main Condenser Offgas Hydrogen Monitor.........................

B.......

3.7-17 Main Condenser Explosive Gas Mixture................................

B 3.7-19 Liquid Holdup Tanks.............

B 3.7-20 ESSW Pumphouse Ventilation......

..................................... TRM/B 3.7-21 Main Condenser Offgas Pretreatment Logarithmic Radiation Monitoring Instrumentation.................

TRM/B 3.7-22 Snubbers.................

B 3.7-24 Control Structure HVAC.................

TRM/B 3.7-31 Spent Fuel Storage Pools.................

TRM/B 3.7-33 B 3.8.1 Primary Containment Penetration Conductor Overcurrent Protective Devices...........

TRM/B 3.8-1 B 3.8.2.1 Motor Operated Valves Thermal Overload Protection -

Continuous......

TRM/B 3.8-3 B 3.8.2.2 Motor Operated Valves Thermal Overload Protection -

Automatic.TRM/B 3.8-4 B 3.8.3 Diesel Generator (DG) Maintanence Activities.

TRMIB 3.8-5 B 3.8.4 24VDC Electrical Power Subsystem.TRM/B 3.8-6 B 3.8.5 Degraded Voltage Protection....................

TRM/B 3.8-16 B 3.8.6 Ermergency Switchgear Room Cooling.TRM/B 3.8-17 B.3.9.1 B 3.9.2 B 3.9.3 B 3.10.1 B 3.10.2 B 3.10.3 B 3.10.4 B 3.11.1.1 B 3.11.1.2 B 3.11.1.3 B 3.11.1.4 B 3.11.1.5 B 3.11.2.1 B 3.11.2.2 B 3A11.2.3 B 3.11.2.4 B 3.11.2.5 Decay Time...........

B 3.9-1 Communications.................

B 3.9-2 Refueling Platform...

B 3.9-3 Sealed Source Contamination.B 3.10-1 MODE 5 Shutdown Margin Test RPS Instrumentation......................... B 3.10-2 Independent Spent Fuel Storage Installation (ISFSI)........

TRM/B 3.10-4 Leading Edge Flow Meter (LEFM)........

TRM/B 3.10-6 Liquid Effluents Concentration........

B 3.11-1 Liquid Effluents Dose........

B 3.11-4 Liquid Waste Treatment System........

B 3.11-6 Liquid Radwaste Effluent Monitoring Instrumentation.......................... B 3.11-7 Radioactive Liquid Process Monitoring Instrumentation............... TRM/B 3.11-10 Dose Rate.......................................

........ TRM/B 3.11-12 Dose - Noble Gases..............

B 3.11-16 Dose - Iodine, Tritium, and Radionuclides in Particulate Form.....

B 3.11-18 Gaseous Radwaste Treatment System.TRM/

3.11-20 Ventilation Exhaust Treatment System.TRM/B 3.11-21 SUSQUEHANNA - UNIT 2 TRM / TOC-5 EFFECTIVE DATE 11/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)

PPL Rev. 3 SECTION B 3.11.2.6 B 3.11.3 B 3.11.4.1 B 3.11.4.2 B 3.11.4.3 B 3.12 B.3.12.1 B.3.12.2 B.3.12.3 TITLE PAGE Radioactive Gaseous Effluent Monitoring Instrumentation............................

_ TRM/B 3.11-24 Total Dose.B 3.11-26 Monitoring Program.B 3.11-28 Land Use Census.B 3.11-34 Interlaboratory Comparison Program.TRMtB 3.11-36 LOADS CONTROL PROGRAM.

TRM/B 3.12-1 Crane Travel - Spent Fuel Storage Pool.

TRMIB 3.12-1 Heavy Loads Requirements.

TRMtB 3.12-2 Light Loads Requirements.TRMtB 3.12-3 TRM2 Tedx TOC 11111104 SUSQUEHANNA - UNIT 2 TRM /TOC-6 EFFECTIVE DATE 11/15/2004

Instrument Trip Setpoint Program PPL Rev. 2 2.2 2.0 PLANT PROGRAMS AND SETPOINTS 2.2 Instrument Trip Setpoint Table The Instrument Trip Setpoint Limits in Table 2.2-1 are the Trip Setpoint value limits that were contained in the Instrumentation Setpoint tables for protection systems and other functions important to safety that were included in the scope of the original Standard Technical Specifications. Actual instrument setpoints are established utilizing the Allowable Values specified in the Technical Specifications and Technical Requirements. Allowable Values are established in the Reference LCOs and TROs identified in this Table. TRO references are enclosed in square brackets.

Instrumentation process setpoints for the listed subsystems and trip functions are set consistent with the Trip Setpoint Limit Column of Table 2.2-1. Actual setpoints are established in accordance with engineering procedures.

Alarm sbtpoints and other non-protection system trip settings as may be found in the Technical Specifications or in the Technical Requirements are not included in this table.

Reference NDAP-QA-1104 Setpoint Change Control

.N SUSQUEHANNA - UNIT 2 TRM / 2.0-5 EFFECTIVE DATE 04/0211999

Instrument Trip Setpoint Program 2.2 PPL Rev. 2 TABLE 2.2-1 (Page 1 of 8)

INSTRUMENTATION SETPOINTS I

LCO [TRO]

TRIP FUNCTION TRIP SETPOINT 2.2.1 Reactor Protection 2.2.1.1 3.3.1.1 Intermediate Range Monitor, Neutron Flux -

  • 120/125 divisions of full High scale 2.2.1.2 3.3.1.1 Average Power Range Monitor, Neutron Flux
  • 15% of RATED THERMAL POWER

- High Setdown 2.2.1.3 3.3.1.1 Average Power Range Monitor, Flow Biased See COLR - TRO 3.2 Simulated Thermal Power - High Two Loop Operation 2.2.1.4 3.3.1.1 Average Power Range Monitor, Flow Biased See COLR - TRO 3.2 Simulated Thermal Power - High Single Loop Operation 2.2.1.5 3.3.1.1 Average Power Range Monitor, Flow Biased

  • 113.5% of RATED THERMAL Simulated Thermal Power - High Flow POWER Clamped 2.2.1.6 3.3.1.1 Average Power Range Monitor, Fixed Neutron
  • 118% of RATED THERMAL POWER Flux - High 2.2.1.7 3.3.1.1 Reactor Vessel Steam Dome Pressure - high

2.2.1.9 3.3.1.1 Main Steam Isolation Valve - Closure

  • 10% closed 2.2.1.10 This Section Not Used 2.2.1.11 3.3.1.1 Drywell Pressure - High 1.72 psig 2.2.1.12 3.3.1.1 Scram Discharge Volume Water Level - High
  • 65 gallons

- Level Transmitter 2.2.1.13 3.3.1.1 Scram Discharge Volume Water Level - High

  • 61 gallons

- Float Switch 2.2.1.14 3.3.1.1 Turbine Stop Valve - Closure

> 500 psig Oil Pressure - Low (continued)

(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 2 TRM /2.0-6

. EFFECTIVE DATE 11/15/2004

Instrument Trip Setpoint Program 2.2 PPL Rev. 2 TABLE 2.2-1 (Page 2 of 8)

INSTRUMENTATION SETPOINTS SYSTEM/REFERENCE LCO [TRO]

TRIP FUNCTION TRIP SETPOINT 2.2.1.16 OPRM Instrumentation 2.2.1.16.1 3.3.1.3 Sp Cell Signal Amplitude See COLR - TRO 3.2 2.2.1.16.2

-3.3.1.3 N2 Confirmation Count Permissive See COLR -TRO 3.2 2.2.1.16.3 13.3.9]

TOL Period Confirmation Tolerance 0.10 sec 2.2.1.16.4

[3.3.9]

Ta Averaging Filter 5 sec 2.2.1.16.5

[3.3.9]

Fc Conditioning Filter Cutoff Frequency 1.5 Hz 2.2.1.16.6

[3.3.9]

Tmin Minimum Oscillation Period 1.0 sec 2.2.1.16.7

[3.3.9]

Tmax Maximum Oscillation Period 3.5 sec 2.2.1.16.8

[3.3.9]

Noise Floor Peak Discrimination Threshold 1

2.2.1.16.9

[3.3.9]

Minimum LPRM/Cell Cell Operability 2

Requirement 2.2.1.16.10

[3.3.9]

S1 Peak Threshold Setpoint 1.20 2.2.1.16.11

[3.3.9]

S2 Valley Threshold Setpoint 0.85 2.2.1.16.12

[3.3.9]

Smax Max. Amplitude Trip Setpoint 1.50 2.2.1.16.13

[3.3.9]

DR3 Growth Rate Factor Setpoint 1.60 2.2.1.16.14

[3.3.9]

TI lo SI to S2 Timer Range 0.5 sec 2.2.1.16.15

[3.3.9]

TI hi SI to S2 Timer Range 1.75 sec 2.2.1.16.16

[3.3.9]

T2 lo S2 to(S3 or Smax) Timer Range 0.5 sec 2.2.1.16.17

[3.3.9]

T2 hi S2 to(S3 or Smax) Timer Range 1.75 sec 2.2.2 Isolation Actuation Instrumentation 2.2.2.1 Primary Containment Isolation 2.2.2.1.1 3.3.6.1 Reactor Vessel Water Level Low, Level 3

Ž 13.0 inchesca) 2.2.2.1.2 3.3.6.1 Reactor Vessel Water Level Low Low, Leveel 2 1:-38.0 inches(')

2.2.2.1.3 3.3.6.1 Reactor Vessel Water Level Low Low Low, 2

-129 inches(a)

Level 1 2.2.2.1.4 3.3.6.1 Drywell Pressure - High

  • 1.72 psig

.2.2.2.1.5 3.3.6.143.3.6]

SGTS Exhaust Radiation - High -

23.0 mR/hr 2.2.2.1.6

[3.3.6]

Main Steam Line Radiation - High High

  • 15 x full power background without hydrogen injection (continued)

SUSQUEHANNA - UNIT 2 TRM /2.0-7 EFFECTIVE DATE 11/15/2004

PPL Rev. 2 Instrument Trip Setpoint Program 2.2 TABLE 2.2-1 (Page 3 of 8)

INSTRUMENTATION SETPOINTS I

SYSTEM/REFERENCE LCO rTRO]

TRIP FUNCTION TRIP SETPOINT 2.2.2.2 Secondary Containment Isolation 2.2.2.2.1 2.2.2.2.2 2.2.2.2.3 2.2.2.2.4 2.2.2.2.5 3.3.6.2 3.3.6.2 3.3.6.2 3.3.6.2 3.3.6.2 Reactor Vessel Water Level - Low Low, Level 2 Drywell Pressure - High Refuel Floor High Exhaust Duct Radiation -

High Railroad Access Shaft Exhaust Duct Radiation - High Refuel FloorWall Exhaust Duct Radiation -

High 2-38.0 inchesca)

I 1.72 psig

  • 18 mR/hr
  • 5 mR/hr
  • 21 mR/hr 2.2.2.3 Main Steam Line Isolation 2.2.2.3.1 2.2.2.3.2 2.2.2.3.3 2.2.2.3.4 2.2.2.3.5 2.2.2.3.6 2.2.2.3.7 2.2.2.3.8 3.3.6.1 3.3.6.1 3.3.6.1

.3.3.6.1 3.3.6.1

[3.3.6]

[3.3.6]

Reactor Vessel Water Level - Low Low Low, Level 1 Main Steam Line Pressure - Low Main Steam Line Flow - High Condenser Vacuum - Low Reactor Building Main Steam Une Tunnel Temperature - High This Section Not Used Reactor Building Main Steam Line Tunnel A Temperature - High Turbine Building Main Steam Tunnel Temperature - High 2-129 inches(2) 2 861 psig,

  • 113 psid

,2 9.0 inches Hg vacuum

  • 1771F
  • 99°F
  • 1970F 2.2.2.4 Reactor Water Cleanup System Isolation 2.2.2.4.1 2.2.2.4.2 2.2.2.4.3 2.2.2.4.4 2.2.2.4.5 2.2.2.4.6 2.2.2.4.7 2.2.2.4.8 2.2.2.4.9 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1

[3.3.6]

3.3.6.1

[3.3.6]

3.3.6.1

[3.3.6]

Reactor Vessel Water Level - Low Low, Level 2 RWCU A Flow-High RWCU Flow-High RWCU Penetration Area Temperature - High RWCU Penetration Room Area A Temperature

- High RWCU Pump Area Temperature - High RWCU Pump Room Area A Temperature -

High RWCU Heat Exchanger Area Temperature -

High RWCU Heat Exchanger Room Area A Temperature - High

-38 Inches(a)

  • 59 gpm
  • 462 gpm s 131'F
  • 69°F
  • 1470F
  • s 69TF
  • 1470F
  • 69°F (continued)

(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 2 TRM / 2.0-8 EFFECTIVE DATE 11/15/2004

Instrument Trip Setpoint Program 2.2 PPL Rev. 2 TABLE 2.2-1 (Page 4 of 8)

INSTRUMENTATION SETPOINTS I

SYSTEM/REFERENCE LCO

[TRO]

TRIP FUNCTION TRIP SETPOINT 2.2.2.5 Reactor Core Isolation Cooling System Isolation 2.2.2.5.1 3.3.6.1 RCIC Steam Une A Pressure - High 2.2.2.5.2 3.3.6.1 RCIC Steam Supply Line Pressure - Low 2.2.2.5.3 3.3.6.1 RCIC Turbine Exhaust Diaphragm Pressure

- High 2.2.2.5.4 3.3.6.1 RCIC Equipment Room Temperature - High 2.2.2.5.5 3.3.6.1 RCIC Pipe Routing Area Temperature - High 2.2.2.5.6 3.3.6.1 RCIC Emergency Area Cooler Temperature -

High 2.2.2.5.7 3.3.6.1 Drywell Pressure - High 2.2.2.5.8

[3.3.6]

RCIC Equipment Room A Temperature - High 2.2.2.5.9

[3.3.6]

RCIC Pipe Routing Area A Temperature -

High 2.2.2.6 High Pressure Coolant Injection System Isolation s 188 inches H20 2 60 psig

< 10.0 psig S 1670 F

  • 1676F s 1670F
  • 1.72 psig s 89°F s 89°F 2.2.2.6.1 2.2.2.6.2 2.2.2.6.3 2.2.2.6.4 2.2.2.6.5 2.2.2.6.6 2.2.2.6.7 2.2.2.6.8 2.2.2.6.9 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1

[3.3.61

[3.3.6]

Cl Steam Urie A Pressure - High

'l Steam Supply Une Pressure - Low CI Turbine Exhaust Diaphragm Pressure -

I

'I Equipment Room Temperature - High

'I Emergency Area Cooler Temperature -

I

'I Pipe Routing Area Temperature - High Nell Pressure - High

'I Equipment Room A Temperature - High

'l Pipe Routing Area A Temperature -

I actor Vessel Water Level - Low, Level 3 actor Vessel Steam Dome Pressure - High R Flow-High s 370 inches H20 2o104 psig

- 10 psig s 1670F s 1670F s 1670 F s 1.72 psig s 890 F, s 890F 2 13.0 inches(a) s 98 psig s 25,000 gpm 2.2.2.7 Shutdown Cooling/System Isolation 2.2.2.7.1 2.2.2.7.2 2.2.2.7.3 2.2.3 3.3.6.1 3.3.6.1

[3.3.6]

ECCS Actuation 2.2.3.1 Core Spray System 2.2.3.1.1 3.3.5.1 2.2.3.1.2 2.2.3.1.3 3.3.5.1 3.3.5.1 Reactor Vessel Water Level - Low Low Low, Level 1.

Drywell Pressure - High Reactor Vessel Steam Dome Pressure - Low -

Injection permissive 2-129 inches(a) s 1.72 psig 2 413, s 427 psig (continued)

(') See Figure 2.2-1 SUSQUEHANNA - UNIT 2 TRM / 2.0-9 EFFECTIVE DATE 11/15/2004

Instrument Trip Setpoint Program 2.2 PPL Rev. 2 TABLE 2.2-1 (Page 5 of 8)

INSTRUMENTATION SETPOINTS I

SYSTEM/REFERENCE LCO

[TRO]

TRIP FUNCTION TRIP SETPOINT 2.2.3.2 LPCI Mode of RHR System 2.2.3.2.1 2.2.3.2.2 2.2.3.2.3 2.2.3.2.4 3.3.5.1 3.3.5.1

.3.3.5.1 3.3.5.1 Reactor Vessel Water Level - Low Low Low, Level I Drywell Pressure - High Reactor Vessel Steam Dome Pressure - Low, Injection permissive Reactor Vessel Steam Dome Pressure - Low, Recirculation Discharge Valve permissive 2 -129 inches(a)

  • 1.72 psig 2 413,
  • 427 psig 2Ž236 psig, decreasing 2.2.3.3 HPCI System 2.2.3.3.1 2.2.3.3.2 2.2.3.3.3 2.2.3.3.4 3.3:5.1 3.3.5.1 3.3.5.1 3.3.5.1 Reactor Vessel Water Level - Low Low, Level 2 Drywell Pressure - High Condensate Storage Tank Level - Low Reactor Vessel Water Level - High, Level 8 2Ž-38 inches<')
  • 1.72 psig 2 36.0 inches above tank bottom

'3.3.5.1 3.3.5.1 3.3.5.1

  • 3.3.5.1 3.3.5.1
  • 1.72 psig
  • 102 seconds 2 135,ls 155 psig 2 121,* 129 psig 2 13 inches
  • 420 seconds Loss of Power - ECCS Actuation 4.16kv ESS Bus Undervoltage (Loss of Voltage c 20%)

3.3.8.1 3.3.8.1 Bus Undervoltage Time delay 2 823.2;

  • 856.8 Volts 2 0.4, *0.6 seconds (continued)

(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 2 TRM / 2.0-10 UIEFFECTIVE DATE 11/15/2004

Instrument Trip Setpoint Program 2.2.

PPL Rev. 2 TABLE 2.2-1 (Page 6 of 8)

I INSTRUMENTATION SETPOINTS SYTMREEEC LC.O 2.2.3.5.2 2.2.3.5.21 2.2.3.5.2.2 2.2.3.5.3 2.2.3.5.3.1 2.2.3.5.3.2 2.2.3.5.3.4 2.2.3.5.4 2.2.3.5.4.1 2.2.3.5.4.2 2.2.3.5.5 2.2.3.5.5.1 2.2.3.5.5.2 2.2.4 2.2.4.1 2.2.4.1 2.2.5 2.2.5.1 2.2.5.2 2.2.6 2.2.6.1 2.2.6.2 2.2.6.3 SYSTEWJREFERENCE LCO-

[TRO]

TRIP FUNCTION 4.16kV ESS Bus Undervoltage (Degraded Voltage < 65%)

3.3.8.1 Bus Undervoltage 3.3.8.1 Time delay 4.16kV ESS Bus Undervoltage (Degraded Voltage, < 93%)

3.3.8.1 Bus Undervoltage 3.3.8.1 Time Delay (Non-LOCA) 3.3.8.1 Time Delay (LOCA) 480V ESS Bus OB565 Undervoltage (Degraded Voltage, < 65%)

[3.8.5]

480V Basis

[3.8.5]

Time Delay 480V ESS Bus 0B565 Undervoltage (Degraded Voltage, < 92%)

[3.8.5]

480V Basis

[3.8.5]

Time Delay ATWS Alternate Rod Injection and Recirculation Pump Trip 3.3.4.2/[3.1.1]

Reactor Vessel, Water Level - Low Low, Level 2 3.3.4.2/[3.1.1]

Reactor Vessel Steam Dome Pressure - High End of Cycle Recirculation Pump Trip 3.3.4.1 Turbine Stop Valve-Closure 3.3.4.1 Turbine Control Valve - Fast Closure Reactor Core Isolation Cooling System Actuation 3.3.5.2 Reactor Vessel Water Level - Low Low, Level 2 3.3.5.2 Reactor Vessel Water Level - High, Level 8

3.3.5.2 Condensate Storage Tank Level - Low -

TRIP SETPOINT 22641.1,

  • 2748.9 Volts 2 2.7, *3.3 seconds 2 3829.3,
  • 3906.7 Volts 2 4 minute, 30 seconds
  • 5 minute, 30 seconds 29,
  • 11 seconds 2 308.9,
  • 315.1 Volts 24.5,
  • 5.5 seconds 2437.6, *446.4 Volts 29,
  • 11 seconds 2Ž-38 inches( '

s 1135 psig

  • 5.5% closed

' 500 psig 2-38 inchesta'

.. 54 inchescs'

Ž 36.0 inches above tank bottom (continued)

(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 2 TRM / 2.0-11 QEFFECTIVE DATE 1111512004

Instrument Trip Setpoint Program 2.2 PPL Rev. 2 TABLE 2.2-1 (Page 7 of 8)

INSTRUMENTATION SETPOINTS I

SYSTEM/REFERENCE LCO

[TRO]

TRIP FUNCTION TRIP SETPOINT 2.2.7 2.2.7.1 2.2.7.1.1 2.2.7.1.2 2.2.7.1.3 2.2.7.2 2.2.7.2.1 2.2.7.22 2.2.7.23 2.2.7.24 2.2.7.25 2.2.7.3 2.2.7.3.1 2.2.7.3.2 2.2.7.4 2.2.7.4.1 2.2.7.4.2 Control Rod Block Rod Block Monitor 3.3.2 Low Power Range Upscale - Two Loop Operation 3.3.2 Low Power Range Upscale - Single Loop Operation Downscale APRM

[3.1.3]

Flow Biased Simulated Thermal Power-High

- Two Loop Operation

,[3.1.3]

Flow Biased Simulated Thermal Power High

- Single Loop Operation 13.1.3]

Flow Biased Simulated Thermal Power High

- High Flow Clamped

[3.1.3]

Downscale

[3.1.3]

Neutron Flux - High Setdown Source Range Monitors

[3.1.3]

Upscale

[3.1.3]

Downscale Intermediate Range Monitors

[3.1.3]

Upscale

[3.1.3]

Downscale S 0.58W + 52%

  • 0.58W + 47%

5%

See COLR - TRO 3.2 See COLR - TRO 3.2

  • 108% of RATED THERMAL POWER 2 5% of RATED THERMAL POWER
  • 12% of RATED THERMAL POWER
  • 2E5 cps 2 0.7 cps(b)
  • 1081125 divisions of full scale 2 5/125 divisions of full scale 2.2.7.5 2.2.7.5.1 2.2.7.6 2.2.7.6.1 2.2.7.6.2 Scram Discharge Volume

[3.1.3]

Water Level - High Reactor Coolant System Recirculation Flow

  • 35.9 gallons

[3.1.3]

[3.1.3]

Upscale Comparator 114%

  • 1 0% flow deviation (continued)

° Provided signal-to-noise ratio is 2 2. Otherwise, 2 3 cps.

SUSQUEHANNA - UNIT 2 TRM / 2.0 EFFECTIVE DATE 11/15/2004

Instrument Trip Setpoint Program 2.2 PPL Rev. 2 TABLE 2.2-1 (Page 8 of 8)

INSTRUMENTATION SETPOINTS SYSTEM/REFERENCE LCO

[TRO]

TRIP FUNCTION TRIP SETPOINT 2.2.8 CREOASS 2.2.8.1 3.3.7.1 Main Control Room Outside Air Intake

Level 2 2.2.8.1.2 3.3.7.1 Drywell Pressure-High

  • 1.72 psig 2.2.8.1.3 3.3.7.1 Refuel Floor High Exhaust Duct Radiation
  • 18 mR/hr

- High 2.2.8.1.4 3.3.7.1 Railroad Access Shaft Exhaust Duct

  • 5 mR/hr Radiation - High 2.2.8.1.5 3.3.7.1 Refuel Floor Wall Exhaust Duct Radiation
  • 21 mR/hr

- High 2.2.9 Feedwater/Main Turbine Trip System Actuation 2.2.9.1 3.3.2.2 Reactor Vessel Level - High

  • 54.0 inches<a)

'2.2.10 MVP Isolation 2.2.10.1 13.3.11]

Main Steam Line Radiation - High High

  • 15 x full power background without hydrogen injection t.) See Figure 22-1 I.lN SUSQUEHANNA - UNIT 2 TRM / 2.0-13 EFFECTIVE DATE 11/i5/2004

Instrument Trip Setpoint Table PPL Rev. 2 2.2 9'

g ne8,

,v,, j, 81

, i

.7I

...7 BOTTOMHF STEAK DRYER SKIRT FEED 4?8. 5-

> ATER

,~.

50-; ; ' '

..WATER LEVEL NOENLAIURE 0EIGlIT.:BOVE NO.

VESSEL ZERO READING (IN.)

'"'\\

(8):

581.S

+154

7) 566.5

'+39 50 745,,ESSEL (4) 557.5

+30 LAG(3) 540.5

+13 L

E C2)

'489.5'

-38

'*)

398.5

-129.

0O 658.-L

':MAIN

, LINE WIDE 00

.7 rAM

-581.5 (8)

+60

+60+60

+60

-566;5 (-7).; c

,8) -54. t7)ii7' 50

.S:(7 s

JiC

()3 ALAM4 S4G7iS (34.CC 311

5-

-527.'5:-

INSTRQ TRIPSi o

RE.

ICTc

=489.5 (2) --

38 SCAM.

4845 CORE CONTRIBUTE O-

.SPFRA'Y (2) INITIATE RCIC.

TO ADS so

-HPCI.

. ARI TRIP, RECIRC PUMS:

00 398.5(1)

-129 (1).INITIATEARHR.

CS 366. -START DIESEL so-

-150 CONTRIBUTE TO ADS

ACTIVE, CLOSE MSIV'S so-21 63 00-

-181.;0-RECIRC INLET 50-_

NO7ZLE so-NOTE: SCALE IN INCHES 50o _

ABOVE VESSEL.ZERO

.4

. 4

. 3 I

3 j

I

. FIGURE 2.2-1: :

REACTOR VESSEL WATER LEVEL-CADMI 1D P102..2.1 SUSQUEHANNA - UNIT 2 TRM / 2.0-14 EFFECTIVE DATE 1111512004

Core Operating Limits Report (COLR) 3.2.1 PPL Rev. 3 3.2 Core Operating Limits Report (COLR) 3.2.1 Core Operating Umits Report (COLR)

TRO 3.2.1 APPLICABILITY:

The Core Operating Limitsspecified in the attached COLR shall be met.

Specified in the referenced Technical Specifications.

ACTIONS CONDITION' REQUIRED ACTION COMPLETION TIME A. Core Operating Umits not A.1 Perform action(s)

Specified in referenced met.

described in referenced Technical Technical Specification.

Specifications.

TECHNICAL REQUIREMENT SURVEILLANCE SURVEILLANCE FREQUENCY NOTE

-N/A No associated Surveillances. Surveillances are implemented in the applicable Technical Specifications.

SUSQUEHANNA - UNIT 2 3.2-1

.1EFFECTIVE DATE 8/31/1998

PPL Rev. 3 Susquehanna Unit 2 Cycle PL-NF-03-001 Rev. 4 Page 1 of 37 SES 12 CORE OPERATING LIMITS REPORT-Nuclear Fuels Engineering November 2004 II p~I *~K WMIPWANNA IINTT 2

..- -------- I----

TRM/3 9-2

~II~f~flANNAuNI 2 TM/5~2-2FFFPCTTVF flATF 11/1S/2064

' PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 2 of 37 CORE OPERATING LIMITS REPORT REVISION DESCRIPTION INDEX Rev.

Affected No.

Sections DescriptlonlPurpose of Revision 0

ALL Issuance of this COLR is in support of Unit 2 Cycle 12 operation.

1 5.0 This revision adds a text box to all appropriate plots. This text box Indicates 6.0 that for all bypass operable cases, four bypass valves are assumed 8.0 operable. For the bypass inoperable cases, the text box indicates that two or more bypass valves are assumed inoperable.

This revision was generated in response to Facility Operating License Amendment 185 which altered SR 3.7.6.1.

This revision is administative in nature and no underlying calculations or plotted data were altered.

2 TOC This revision adds the Power I Flow map to the COLR. Section 1.0 was 1.0 revised to include the stability regions as part of the COLR. The Power I 9.0 Flow map was added as Section 9.0. The Reference section was 10.0 renumbered as Section 10.0 and a stability reference added.

This revision is administrative in nature since the Power R Flow map is already included in NDAP-QA-0338.

3 5.0 The figures within Section 5.0 and Section 8.0 are revised to incorporate the 8.0 0.02 MCPR Safety Limit reduction approved by Amendment No. 191.

Figure 5.2-2 is revised to correct the Operating Limit error documented by 10.0 CR 606127.

4 TOC This revision changes the Power / Flow map and adds setpoints for the 1.0 OPRM system. The change to the Power / Flow map provides direction 2.0 when the OPRM system is OPERABLE and inoperable. The setpoints for 9.0 the OPRM system are set to reliably detect and suppress anticipated stability 10.0 related power oscillations while providing a high degree of confidence that 11.0 the MCPR safety limit is not violated.

FORM NFP-OA-008-2, Rev. 1 SUSQUEHANNA UNIT 2 TRM/3.2-3 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 3 of 37 SUSQUEHANNA STEAM ELECTRIC STATION Unit 2 Cycle 12 CORE OPERATING LIMITS REPORT Table of Contents

1.0 INTRODUCTION

4 2.0 DEFINITIONS...........................................................................................................5 3.0 SHUTDOWN MARGIN.....................................................

.6 4.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)........................ 7 5.0 MINIMUM CRITICAL POWER RATIO (MCPR).......

9 6.0 LINEAR HEAT GENERATION RATE (LHGR) 20 7.0 AVERAGE POWER RANGE MONITOR (APRM) GAIN AND SETPOINTS 23 8.0 RECIRCULATION LOOPS - SINGLE LOOP OPERATION.

26 9.0 POWER I FLOW MAP.................,

33 10.0 OPRM SETPOINTS..................................................................................................35

11.0 REFERENCES

36 SUSQUEHANNA UNIT 2 TRM/3.2-4 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 4 of 37

1.0 INTRODUCTION

This CORE OPERATING LIMITS REPORT for Susquehanna Unit 2 Cycle 12 is prepared in accordance with the requirements of Susquehanna Unit 2, Technical Specification 5.6.5. As required by Technical Specifications 5.6.5, core shutdown margin, the core operating limits, APRM setpoints, and OPRM setpoints presented herein were developed using NRC-approved methods and are established such that all applicable limits of the plant safety analysis are met.

SUSQUEHANNA UNIT 2 TRM/3.2-'5 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 5 of 37 2.0 DEFINMONS Terms used in this COLR but not defined in Section 1.0 of the Technical Specifications or Section 1.1 of the Technical Requirements Manual are provided below.

2.1 The AVERAGE BUNDLE EXPOSURE shall be equal to the total energy produced by the bundle divided by the total initial weight of uranium in the fuel bundle.

2.2 The AVERAGE PLANAR EXPOSURE at a specified height shall be equal to the total energy produced per unit length at the specified height divided by the total initial weight of uranium per unit length at that height.

2.3 The FRACTION OF LIMITING POWER DENSITY (FLPD) shall be the LHGR existing at a given height divided by the applicable LHGR for APRM Setpoint Umit for that bundle type.

2.4 The FRACTION OF RATED THERMAL POWER (FRTP) shall be the measured THERMAL POWER dMded by the RATED THERMAL POWER.

2.5 FDLRX is the ratio of the maximum LHGR calculated by the core monitoring system for each fuel bundle divided by the LHGR limit for the applicable fuel bundle type.

2.6 MFLCPR is the ratio of the applicable MCPR operating limit for the applicable fuel bundle type divided by the MCPR calculated by the core monitoring system for each fuel bundle.

2.7 MAPRAT is the ratio of the maximum APLHGR calculated by the core monitoring system for each fuel bundle divided by the APLGHR limit for the applicable fuel bundle type.

2.8 FDLRC is the ratio of the maximum LHGR calculated by the core monitoring system for each fuel bundle divided by the LHGR for APRM Setpoint Limit for the applicable fuel bundle type.

2.9 OPRM is the Oscillation Power Range Monitor. The Oscillation Power Range Monitor (OPRM) will reliably detect and suppress anticipated stability related power oscillations while providing a high degree of confidence that the MCPR safety limit is not violated.

2.10 Np is the OPRM setpoint for the number of consecutive confirmations of oscillation half-cycles that will be considered evidence of a stability related power oscillation.

2.11 Sp is the OPRM trip setpoint for the peak to average OPRM signal.

2.12 Fp is the core flow, in Mlbm I hr, below which the OPRM RPS trip is activated.

SUSQUEHANNA UNIT 2 TR.M/3.2-6 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 6 of 37 3.0 SHUTDOWN MARGIN 3.1 Technical Specification Reference Technical Specification 3.1.1 32 Description The SHUTDOWN MARGIN shall be equal to or greater than:

a) 0.38% Ak/k with the highest worth rod analytically determined OR b) 0.28% Ak/k with the highest worth rod determined by test Since core reactivity will vary during the cycle as a function of fuel depletion and poison bumup, Beginning of Cycle (BOC) SHUTDOWN MARGIN (SDM) tests must also account for changes in core reactivity during the cycle. Therefore, the SDM measured at BOO must be equal to or greater than the applicable requirement from either 3.2.a or 3.2.b plus an adder, UR". The adder, 'R", is the difference between the calculated value of maximum core reactivity (that is, minimum SDM) during the operating cycle and the calculated BOO core reactivity. If the value of "R7 is zero (that is, BOO is the most reactive point in the cycle) no correction to the BOC measured value is required.

The SHUTDOWN MARGIN limits provided in 3.2a and 3.2b are applicable in MODES 1, 2,3, 4, and 5. This incluides core shuffling.-

SUSQUEHANNA UNIT 2 TRM/3.2-7 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 7 of 37 4.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) 4.1 Technical Specification Reference Technical Specification 3.2.1 4.2 Description The APLHGRs for ATRIUwhm-1 0 fuel shall not exceed the limit shown in Figure 4.2-1.

The APLHGR limits in Figure 42-1 are valid for Main Turbine Bypass Operable and Inoperable and EOC-RPT Operable and Inoperable in Two Loop operation.

The APLHGR limits for Single Loop operation are provided in Section 8.0.

SUSQUEHANNA UNIT 2 TRM/3.2-8 EFFECTIVE DATE 11/15/2004

(.9~

(I)

C=

ILA

'-4

-1o SSES UNIT 2 CYCLE 12

.19-14'-

tt12 -

E 0-c rN) a)v 0 10 -

ti

.1 ~I a

a a

a.. a...S.

a a

a a

a a

a a

a a

a a

a a

a a

a a

a a

a a

a1 a

a

__I._

a a

a a

a a

1--I

.1 a

a a

a a

'--S

  • a a

a a

a..

a a

a a

a a

a a

r-m1

-I,

-1f F-4

.-C

-a (71 c
)

CD 0~

6 -

4-a 0

10000 20000 30000 40000 50000 Average Planar Exposure (MWD/MTU)

AVERAGE PLANAR LINEAR HEAT GENERATION RATE LIMIT VERSUS AVERAGE PLANAR EXPOSURE TWO LOOP OPERATION ATRIUMTh.10 FUEL FIGURE 4.2-1 60000 70000 00U m

m $rf Q

a CD Z

o 0

co 6

4' 0

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 9 of 37 5.0 MINIMUM CRMCAL POWER RATIO (MCPR) 5.1 Technical Specification Reference Technical Specification 3.2.2,3.7.6, and 3.3.4.1 5.2 Description The MCPR limit is specified as a function of core power, core flow, average scram insertion time per Section 5.3 and plant equipment operability status. The MCPR limits for all fuel types (ATRIUM-10) shall be the greater of the Flow-Dependent or the Power-Dependent MCPR, depending on the applicable equipment operability status.

a)

EOC-RPT and Main Turbine Bypass Operable Figure 5.2-1: Flow-Dependent MCPR value determined from BOC to EOC Figure 5.2-2: Power-Dependent MCPR value determined from BOC to EOC b)

Main Turbine Bypass Inoperable / EOC-RPT Operable Figure 5.2-3: Flow-Dependent MCPR value determined from BOC to EOC Figure 5.2-4: Power-Dependent MCPR value determined from BOC to EOC c)

EOC-RPT Inoperable I Main Turbine Bypass Operable Figure 5.2-5: Row-Dependent MCPR value determined from BOC to EOC Figure 5.2-6: Power-Dependent MCPR value determined from BOC to EOC The MCPR limits in Figures 5.2-1 through 5.2-6 are valid for Two Loop operation.

The MCPR limits for Single Loop operation are provided in Section 8.0.

5.3 Average Scram Time Fraction Table 5.3-1 provides the relationship between average scram time to control rod position and scram time fraction. The evaluation of scram insertion time data, as it relates to the attached table should be performed per Reactor Engineering procedures.

SUSQUEHANNAUNIT 2.

TRM/3.2-10 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 10 of 37 EOC-RPT and Main Turbine Bypass Operable SUSQUEHANNA UNIT 2 TRM/3.2-11 EFFECTIVE DATE 11/15/2004

C-z r-Jo 2=

Dr R

SSES UNIT 2 CYCLE 12 2.3 1*

I V

I I

I I

LEGEND 2.2 2.1 r

I t

CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME I.

I 4

4-2.0 E9 1.9

_. 0 j

I2 1.8 0.2 1.7

4.

I 4.

SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2

.lUSED IN DETERMINING MFLCPR

____1 jLJ-L..

1

-u r-co.

1.B -t(30,1.54)-

a i

S r-n m

.C-)

m

-1 m

t-h&

'-a

'-a N3 1.5 1.4 (45.7,1.47I)

I I

I IL.:.

W

. - I......

j A

I S

[REFEREN-CE: T.S. 3.2.2_

I I

4.

I I' B m - -

m I B

a I -(1 U1,1.47)

(108,1.45)

.(6

,1.4_)-1I I

I 1.3 30 40 50.

60 70 80 90 100 110 Total Core Flow (MLBIHR)

MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW EOC-RPT AND MAIN TURBINE BYPASS OPERABLE TWO LOOP OPERATION (BOC TO EOC)

FIGURE 5.2-1

-u CD 0

-4' C.,

CDla I-z

'1 0

SSES UNIT 2 CYCLE 12

(

Vr C-,

r-m M-1 3.0 2.9 2.8 2.7 2.6 2.5 CA)

C~3

_, 2.4 E.

-J 2.3 2.2 O 2.1 a 2.0 1.9

-g I-CD 1.8 m

C-4 m

CI m

'-4~-S tU, CS.r.3 1.7 1.6 1.5 1.4 1.3 (100,1.47)

(100,1.45) 20 30 40 50 60 70 80 90 Core Power (% RATED)

MCPR OPERATING LIMIT VERSUS CORE POWER EOC-RPT AND MAIN TURBINE BYPASS OPERABLE TWO LOOP OPERATION (BOC TO EOC)

FIGURE 5.2-2 100 (a

(D Z

- 6 o

-g C.0

PPL Rev. 3 PL-NF-03-OO1 Rev. 4 Page 13 of 37 Main Turbine Bypass Inoperable I EOC-RPT Operable SUSQUEHANNA UNIT 2 TRM/3.2-14 EFFECTIVE DATE 11/15/2004

(.

I T

SSES UNIT 2 CYCLE 1.2

(..=

(A, (In m

C=

I._4

--i I\\.)

2.3 2.2 2.1 I

I

.4 4

I 5GEND URVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME URVE B: REALISTIC AVERAGE SCRAM INSERTION TIME I

I9 I

1*

I I

I I

r I

I 2.0 I

.9

.9-1 I

SAFETY ANALYSES ASSUME THAT TWO OR MORE BYPASS VALVES ARE INOPERABLE PER SR 3.7.6.1 OR 3.7.6.2 c3

.IL E 1.9 0 )

1.8 0

a:I 0 uao 1.7 I

4.

l1 I

USED IN DETERMINING MFLCPR r-I I

T

.(30,1.7 -n}.

-I I

I I

I

.t I

4 4

4-A 1,

I B

-t~

I(108,1.77)

-u

-u I-CD0 1.6

,rnen rri C-n

.4-m m

-i

'-4 r%)

1.5 1.4 1.3

~.

I RERNCE: T.S. 3.7.6 and 3.2

_ I._ _ _ _ _ _ _

40 50 30 60 70 80 90,

100 110 Total Core Flow (MLBIHR).

MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW MAIN TURBINE BYPASS INOPERABLE I EOC-RPT OPERABLE TWO LOOP OPERATION (BOO TO EOC)

FIGURE 5.2-3

-u w

U3 (D

-0

-.4 2,

J.0

-u z

-n 6

Q!.

Ln C=

Ln

-- I r-a SSES UNIT 2 CYCLE 12 3.0 2.9 2.8 2.7 2.6 -. 1 r i:

LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME

-(25,2.52)'

I II I

I I

I 2.5

\\ I I

I 1I]

SAFETY ANALYSES ASSUME THAT TWO OR MORE BYPASS VALVES ARE INOPERABLE PER SR 3.7.6.1 OR 3.7.6.2 co~

= 2.4 E

2.3 0,

e 2.2 O 2.1 IL 2.0 1.9 I

I I

I I

l_\\_l_ljjjUSED IN DETERMINING MFLCPR Pll

- -- (40,

_00 B..

(60.1,1.77)

I 10 1.8 (100,1.77)

P1-n

-I,

-I A-1

'-a&

011 N3 CD 1.7 1.6 1.5 -H

REFERENCE:

T.S. 3.7.6 and 3.2.2[-I I

4.

4 I

Y I

I I.

1.4 1.3I

.1

_ I I

I I

I I

20 30 40 50 60 70 80 90 100 Core Power (% RATED)

MCPR OPERATING LIMIT VERSUS CORE POWER MAIN TURBINE BYPASS INOPERABLE I EOC-RPT OPERABLE TWO LOOP OPERATION (BOC to EOC)

FIGURE 5.2-4 (0

co

-L

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 16 of 37 EOC-RPT Inoperable I Main Turbine Bypass Operable SUSQUEHANNA UNIT 2 TRM/3.2-17 EFFECTIVE DATE 11/15/2004

(s-C(A

-I D,

SSES UNIT 2 CYCLE 12 2.3 2.2 2.1

4.

.9

.9-ID A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME B: REALISTIC AVERAGE SCRAM INSERTION TIME I~~~

MAI=siRV I

I I

-- I 2.0 I

t

.9 I

SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 K

C.0

. N, 4'

E 1.9 0I c

! 1.8 0.

0.

0a o 1.7 I

I I

I.1' I

USED IN DETERMINING MFLCPR I

I

__ _ I_ _ I I -.

1 '

1 I

1'--

-u-u I-i:o c0 1.6 1:

1 ___

4.

.4

.4 1

I

4.

.4 (30,1.54) rri n

-n m

0 m

-i I-A

'-4

.4

.4 A

B (108,1.54)

4.

.4 1.5 1.4 II1

REFERENCE:

T.S. 3.3.4.1 and 3.2.2

=I

=

1.3 30 40 50 60 70

  • 80 90 100 110 Total Core Flow (MLB/HR)

MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW EOC-RPT INOPERABLE I MAIN TURBINE BYPASS OPERABLE TWO LOOP OPERATION (BOC TO EOC)

FIGURE 5.2-5 PM ID

-o

-4' 0) 0 r-0

-I.

( -.

(j C=

C=

m

'-4 SSES UNIT 2 CYCLE 12 3.0 2.9 2.8 2.7 2.6

_I_ I II I

I I

I LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME I

I '

I I.

I I

II 2.5 I

l I

I I

SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2

-J CA

_, 2.4 3 2.3 tn I= 2.2 O 2.1 0

o. 2.0 0

1.9 (25,2.29)

I.

I I

I I

IL l

(30,2.23)

L USED IN DETERMINING MFLCPR I

I cl 1.8

,(40,179) rn

-n rr-

-I m

'IP Im F-8.

(_3 1.7 1.6

.5 4

I A

_~

I.

4.

4 4

1 I

4.

4 I

I

--

4 I

(100,1.54) 1.5 1.4 1.3 I1

REFERENCE:

T.S. 3.3.4.1 and 3.2.2 I-I I

4.

4 I

I (74,1.54) t I

I I '

I I

I I

I i

I 20 30 40 50 60 70 80 90 100 Core Power (% RATED)

MCPR OPERATING LIMIT VERSUS CORE POWER EOC-RPT INOPERABLE I MAIN TURBINE BYPASS OPERABLE TWO LOOP OPERATION (BOC to EOC)

FIGURE 5.2-6

-U CD 0

-. 4 m,

m zu CD r co6

.0 0

-4.

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 19 of 37 Table 5.3-1 Average Scram Time Fraction Table For Use With Scram rime Dependent MCPR Operating ULmits Control Rod Average Scram Time to Position (seconds)

Position 45 0.470 0.480

.OA90 0.500 0.510 0.520 39 0.630 0.676 0.722 0.768 0.814 0.860 25 1.500 1.582 1.664 1.746 1.828 1.910 5

2.700 2.848

.2.996 3.144 3.292 3.440 Scram Time

.0.000 0.200 0.400 0.600 0.800 1.000 Fraction Average Scram Realistic Maximum Insertion Time Allowable SUSQUEHANNA UNIT 2 TRM/3.2-20 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 20 of 37 6.0 LINEAR HEAT GENERATION RATE (LHGR) 6.1 Technical Specification Reference Technical Specification 3.2.3 and 3.7.6 6.2 Description The LHGR limits are specified below as a function of Main Turbine Bypass operability for each fuel type as follows:

Main Turbine Bvpass Operable The LHGR for ATRIUM'-10 fuel shall not exceed the LHGR limit determined from Figure 6.2-1.

Main Turbine Bypass Inoperable The LHGR for ATRIUM'm-10 fuel shall not exceed the LHGR limit determined from Figure 6.2-2.

The LHGR limits in Figures 6.2-1 and 6.2-2 are valid for Two Loop and Single Loop operation.

SUSQUEHANNA UNIT 2.

TRM/3.2-21 EFFECTIVE DATE 11/15/2004

(.

(.j(

e SSES UNIT 2 CYCLE 12 SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES

'-.ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 Z.

14 -.

1O0134

RFR 0.0,13.4.'

REFERENCE:

T.S.3.2.3 U E ID T RM NN F L X

[

.t

>.> e ww J* wMaa **,.v,<z

@@ *.*o'v.s e2 Z*.

  • wdwZ @USED IN DETERMINING FDLRX..

.~...*d6*..d............................

=

0

?

A

-0 C

~~~~.......

I I

o 1

0

-0 10000 20000 30000 40000 50000 60000 70000 Average Planar Exposure (MAWD/MTU)

W~

LINEAR HEAT GENERATION RATE LIMIT VERSUS AVERAGE PLANAR EXPOSURE6 MAIN TURBINE BYPASS OPERABLE CO ATRIUMTM10UE FIGURE 6.2-1

.0 1

____________SSES UNIT 2 CYCLE 12 VALVES ARE INOPERABLE PER SR 3.7.6.1 OR 3.7.6.2 AEYAAYE SUM HTTOO OEBPS a1a a

aa a

R FERENCaEa T..

3.2.3and 3.7.6 a

a a

a

  • USED IN DETERMINING F__X

~~0.0,11.9:

15000,11.9
:::::aaa a

aaaaia a

a.

- 12.--........

0 10*da.

3)

V&c..

a a

a a

a a

a a

a a

'a a

a a

  • a a

a a-a a

a a

a a

a 67000,6.38 a-

a.

a..

a a

a a

a a

a a

a a

a a

0 10000 20000 30000 40000 50000 60000 70000 CDP

~Average Planar Exposure (MWDIMTU)

S LINEAR HEAT GENERATION RATE LIMIT VERSUS AVERAGE PLANAR EXPOSURE a

MAIN TURBINE BYPASS INOPERABLE f

ATRIUMTM-10 FUELA FIGURE 6.2-2

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 23 of 37-7.0 AVERAGE POWER RANGE MONITOR (APRM) GAIN AND SETPOINTS 7.1 Technical Specification Reference Technical Specification 3.2.4 and 3.3.1.1 7.2 Description The APRM flow biased simulated thermal power-upscale scram trip setpoint (S) and flow biased neutron flux-upscale control rod block trip setpoint (SR8) shall be established as specified in Table 7.2-1 and Table 7.2-2, Including any adjustments per Technical Specification LCO 3.2.4.

Technical Specification LCO 3.2.4 provides an option to adjust the APRM setpoints when MFLPD Is greater than FRACTION OF RATED THERMAL POWER (FRTP). The adjustment applies to both the APRM flow biased simulated thermal power-upscale scram trip setpoint and flow biased neutron flux-upscale control rod block trip setpoint for Two Loop and Single Loop operation. The APRM setpoints for Specification 3.2.4 are established in Tables 7.2-1 and 7.2-2.

SUSQUEHANNA UNIT 2 TRM/3.2-24 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 24 of 37 Table 7.2-1 APRM Setpoint for Two Loop Operation Trip Setpoint Allowable Value S

0 (0.58W + 59%/6) T S

S*(0.58W + 62%) T' SR;8 < (0.58W + 50°/6) T Spa 5 (0.58W + 53°/6) T Table 7.2-2 APRM Setpoint for Single Loop Operation Trip Setpoint Allowable Value S s (0.58W + 540/6) T S 5 (0.58W + 57%) T' SRB < (0.58W + 45%) T SRB*< (0.58W + 48%) T where: S and SRB are in percent of RATED THERMAL POWER W =

Loop recirculation'flow as a percentage of the loop recirculation flow which produces a core flow of 100 million lbs/hr T

=

Lowest value of the ratio of FRTP divided by the MFLPD.2 The FLPD is the actual LHGR divided by the applicable LHGR limit for APRM Setpoints. The LHGR limitforAPRM setpointsforATRIUMrm-10fuel shall be taken from Figure 7.2-1.

The LHGR for APRM setpoint limits in Figure 7.2-1 are valid for Main Turbine Bypass Operable and Inoperable and EOC'RPT Operable and Inoperable for both Two and Single Loop operation.

For calculated T-values greater than 1.0, a ratio of 1.0 is used in the above equations.

APRM flow biased simulated thermal power-upscale scram allowable value in this table is equal to the value established in Technical Specification 3.3.1.1.

2 For the calculation of T, the value of MFLPD shall be the maximum value of FDLRC.

I.'/

.SUSQUEHANNA UNIT 2 TRM/3.2-25 EFFECTIVE DATE 11/15/2004

(9-tA C=

P1-

-I4 r%3 16-14'-

o.S 5 u. 1 1500 SSES UNIT 2 CYCLE 12aa 0.0,15.0:

EE E C:....

  • EFaRENCE::T.

. 3 USEDIN DETERMINING FDI.RC

.L

.b.

E..b..S....

  • a

~ a a...

a a

a C-,

'9-4

~-q

$--A S.--

U, PO-6 T

1J Ir-0 (D r.I (0

(D Z

U1.&

4 0

10000 20000 30000 40000 50000 60000 Average Planar Exposure (MWDIMTU)

LINEAR HEAT GENERATION RATE LIMIT FOR APRM SETPOINTS VERSUS AVERAGE PLANAR EXPOSURE ATRIUMYM -10 FUEL FIGURE 7.2-1 70000

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 26 of 37 8.0 RECIRCULATION LOOPS - SINGLE LOOP OPERATION 8.1 Technical Snecification Reference

- Technical Specification 3.2.1, 3.2.2, 3.2.3, 3.2.4, 3.3.4.1, 3.4.1, and 3.7.6 82 Descrintion APLHGR The APLHGR limit for ATRIUM'-10 fuel shall be equal to the APLHGR Limit from Figure 8.2-1.

The APLHGR limits in Figure 8.2-1 are valid for Main Turbine Bypass Operable and Inoperable and EOC-RPT Operable and Inoperable in Single Loop operation.

Minimum Critical Power Ratio Umit The MCPR limit is specified as a function of core power, core flow, and plant equipment operability status. The MCPR limit for all fuel types (ATRIUM'm-1 0) shall be the greater of:

a)

Flow-Dependent MCPR value determined from Figure 8.2-2 OR b)

The Power-Dependent MCPR value determined from one of the following figures, as appropriate:

Figure 8.2-3: EOC-RPT and Main Turbine Bypass Operable from BOC to EOC Figure 8.24: Main Turbine Bypass Inoperable / EOG-RPT Operable from BOC to EOC Figure 8.2-5: EOC-RPT Inoperable (Main Turbine Bypass Operable from BOC to EOC The MCPR limits in Figures 8.2-2 through 8.2-5 are valid only for-Single Loop operation.

Unear Heat Generation Rate Limit The LHGR limits for Single Loop Operation are defined in Section 6.0.

. SUSQUEHANNA UNIT 2 TRM/3.2-27 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 27 of 37 Average Power Range Monitor (APRM) Gain And Setpoints APRM setpoints and the LHGR limit for APRM setpoints for Single Loop operation are defined in Section 7.0.

SUSQUERANNA UNIT 2 TRM/3.2-28 EFFECTIVE DATE 11/15/2004

.ISO SSES UNIT 2 CYCLE 12 14 2.REFERENCE T.S. 3.4;1 and 3.2.1 N)

USED IN DETERMINING MAPRAT L

0 12...

W 0

a a

a I

S Sa0 a

a a

a a

a a

1!.

a 1

a a

a a

000i I

I I

S S

a a

a a

a-I I

e a

aa a

a a

a a

-a S

I S

-i T

67000,4.8 0

10000 20000 30000 40000 50000 60000 70000 c:)

~~Average Planar Exposure (MWDIMTU)

C Dr CD Z

  • AVERAGE PLANAR LINEAR HEAT GENERATION RATE LIMIT VERSUS AVERAGE PLANAR EXPOSURE 0

SINGLE LOOP OPERATION 0

3

.ATRIUMT' 9.10 FUEL 4

FIGURE 8.2-1

E -

SSES UNIT 2 CYCLE 12 C.

(A, C=

Ln C=

--I r13 2.6 2.5 2.4 E 2.3

.EC0, C

r 2.2 0

a.

C.

-1 I

I I

I

. C-EGEND URVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME URVE B: REALISTIC AVERAGE SCRAM INSERTION TIME m

1 1

1 I

I 4

4 USED IN DETERMINING MFLCPR (30,2.20)

A-B I

I

'(108,2.20)

-u r-ml

. 5 Z.1

-n rn

-1

~-4 I.,

.-j 2.0 1.9 REFEREN CE: T.S. 3.4.1.

1

.F 1.8 30 40 50 60 70 80 -

90 100 110 Total Core Flow (MLI/HR)

MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW SINGLE LOOP OPERATION (BOC to EOC)

FIGURE 8.2-2

.u m tJ (D

Z

-~ 6 0

0

i rn R

F-4

-4q SSES UNIT 2 CYCLE 12 3.5 3.4 3.3 3.2 3.1

.I I.

I I

LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME

-_SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 3.0 I-A WE2.9 cr 2.89

-I on 2.8 V 2.7

- 0 2.6 I

2.0

  • 2.5 I

--(25,2.73)-

USED IN DETERMINING MFLCPR i-9 4

Y II nN.

I

_(30,2.67p'i I-4.44

-o I-CD co

-n, rni m

1-4 tI,,

I-aj r%3 2.4 2.3 2.2 2.1 2.0 1.9 A

B (39.4,2.20) 1 REFENIENCE: T.S. 3.4.1 and 3.2l2 I1 I1I-(100,2.20) 20 30 40 50 60 Core Power (% RATED) 70 80 90 100 MCPR OPERATING LIMIT VERSUS CORE POWER EOC-RPT AND MAIN TURBINE BYPASS OPERABLE SINGLE LOOP OPERATION (BOC to EOC)

FIGURE 8.2-3 la 0

-A C,,

CD-u z

0

m C=

1-I C.,

r%3 c-i m

-n m

0

.m I--j I-a 1Oi SSES UNIT 2 CYCLE 12 3.5 3.4 3.3 3.2 3.1 3.0

  • t! 2.9

-J m 2.8 c

Ad 2.7

° 2.6 0.c C.)

2 2.5 2.4 2.3 2.2 2.1 2.0 1.9 LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME (25,3.01)

SAFETY ANALYSES ASSUME THAT TWO OR MORE BYPASS VALVES ARE INOPERABLE PER SA 3.7.6.1 OR 3.7.6.2 USED IN DETERMINING MFLCPR (40,2.39)-.

B-(55.7,2.20) u-o CI, I

I RFERENCE: T.S. 3.4.1, 3.7.6, and 3.2ij 4

4 4

4.

  • .. I I

I

. I 1i (100,2.20)

DO I

-I It

'I 20 30 40 50 60 70 80 90 Core Power (% RATED)

MCPR OPERATING LIMIT VERSUS CORE POWER MAIN TURBINE BYPASS INOPERABLE I EOC-RPT OPERABLE SINGLE LOOP OPERATION (BOC to EOC)

FIGURE 8.2-4 Xu mI l

(D *Z co m 7 co <

0 o.

(L,J K'I--

SSES UNIT 2 CYCLE 12 m

'-1

-- I 3.5 3.4 3.3 3.2 3.1 3.0

-4I Ca)

C\\3 CA

& 2.9 E.-

m 2.8

£

' 2.7 0cc 2.6 0.2 2.5

-u CD, 2.4 m

-nm

-1 m

'-im

~-4 I.-A

$-S

-r-2.3 2.2 2.1 2.0 1.9 (100,2.20) 20 30 40 50 60 70 80 Core Power (% RATED) 90 100 MCPR OPERATING LIMIT VERSUS CORE POWER EOC-RPT INOPERABLE / MAIN TURBINE BYPASS OPERABLE SINGLE LOOP OPERATION (BOC to EOC)

FIGURE 8.2-5 ID 0I ID x -o z

-n

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 33 of 37 9.0 POWER I FLOW MAP 9.1 Technical Specification Reference Technical Specification 3.3.1.3 l

9.2 Description Monitor reactor conditions to maintain THERMAL POWER I core flow outside of.

Stability Regions I and 11 of the Power / Flow map, Figure 9.1.

I If the OPRM Instrumentation is OPERABLE per TS 3.3.1.3, Region I of the Power/ Flow map Is considered an immediate exit region.

If the OPRM Instrumentation is inoperable per TS 3.3.1.3, Region I of the Power I I Flow map is considered an immediate scram region.

l Region II of the Power! Flow map is considered an immediate exit region regardless of the operability of the OPRM Instrumentation.

SUSQUEHANNA UNIT 2 TRM/3.2-34 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 34 of 37 120 -

120

Purpose:

J_

L I _i.L J _

UNIT 2 i--

4<_.^,__POWER I /MFOW MAP.

110 Rod U 110 10Inifal l Date:

/PR R -

F

~od RE l~LST-*

1 1

~~~Tripelln RE rERIOg.

STABuTY REG10 I

Li

_f_Li.J_

i__ L.

5 100i IF OPRM INOPERABLE IUMEtATE SCRA-.

io I I I I

.LW 0

002 I

'LI..

.I

.J.L IE E

gr O-PERA LE APr TE L

-=

  • --I-

.I 4

.19OfO.t LIi

.4.J--

L1-IAW ON-230 TdP Setpolnt I I*j

_I l

r

.r3 e vsn-_

-r

,*MT RO mLLmug

-ETITDEI-910 UED[iA7ELY EXITLAW ON-2784)02 I90 10 I

ReTME MM 8

IJaLJ_

'_L1J__t

__ftttJ_

J -I L I __

-1

@ J -

L4 J 5-L J _ -

l I t Il I

  • Il ll l

9 sI 1-19tXl Xl Z l II I I I I I I F1 0

0 4T 50 0

8 0 t r 7

-0 90 10 i

lnn

-110 NDAP-QA4PowerA-'

FlowI Map SUS TrrE HN UNITr r T/ Rr r

T 1 /1 r

5/ 20 0 r

I r

t-?,

I--SX',-

t, I1 liste of-

,,§__l 8

-F 4 ^-P-F 4-ti.+-

_i_

+

^-

-F

-I-F t- +--i F.

4_

_J_

.,,i*I*I

..sr,,,

..II0 0onn~W rrslr r n -I-

_-ti r I -i-r) niT-r r,

- I-

- rt r U r

If L.

J t-L I

J-I L; J i

1.

i J

J LI 1_040; 4-t;i" e l*

T' T

-.- r or4- -rr,1--_1 ~ "

/

nlr 0;ppr

-armlr in-rt r

.r 1 ~ ~

~

~

~

~

T4 r

200

~rr7 l

~~~

1Xs l-r7ntr5nrtn--

40 J

)-,

L.0

.410 ;_ 1.

11

-i-4sr r

n 9r

-ir w

-Irr i-l hrma oecmlwt 10 4w s d-T -r r T L, -:- rl-l0 I

10 1 20 I0 I4

'SO 40 7

0 90 100 I 10 N~~rala Corelti Flow0 (lr4,h4, 40 Un 4

-I-er I Flo L

a RETI REIO SUQUHAN UNT2lM323 FFCIEDT 11/00

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 35 of 37 10.0 OPRM SETPOINTS I

10.1 Technical Specification Reference I

I Technical Specification 3.3.1.3 10.2 Description Setpoints for the OPRM Instrumentation are established that will reliably detect and suppress anticipated stability related power oscillations while providing a high degree of confidence that the MCPR Safety limit is not violated. The setpoints are described in Section 1.0 and are listed below:

I Sp

=

1.11

=

14 Il Fp

=

65 Mlbm / hr SUSQUEHANNA UNIT 2 TRM/3.2-36 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 36 of 37

11.0 REFERENCES

11.1 The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:

1. PL-NF-90-001-A, 'Application of Reactor Analysis Methods for BWR Design and Analysis," July 1992.
2. PL-NF-90-001, Supplement 1-A, "Application of Reactor Analysis Methods for BWR Design and Analysis: Loss of Feedwater Heating Changes and Use of RETRAN MOD 5.1," August 1995.
3. PL-NF-90-001, Supplement 2-A, "Application of Reactor Analysis Methods for BWR Design and Analysis: CASMO-3G Code and ANFB Critical Power Correlation," July 1996.
4. PL-NF-90-001, Supplement 3-A, "Application of Reactor Analysis Methods for BWR Design and Analysis: Application Enhancements," March 2001.
5. XN-NF-80-19(A), Volume 1, and Volume 1 Supplements 1 and 2 (March 1983),

and Volume 1 Supplement 3 (November 1990), "Exxon Nuclear.Methodology for Boiling Water Reactors: Neutronic Methods for Design and Analysis,"

Exxon Nuclear Company, Inc.

6. XN-NF-80-1 9(P)(A), Volumes 2, 2A, 2B, and 2C "Exxon Nuclear Methodology for Boiling Water Reactors: EXEM BWR ECCS Evaluation Model," September 1982.
7. XN-NF-80-19(P)(A), Volume 3 Revision 2 'Exxon Nuclear Methodology for Boiling Water Reactors Thermex: Thermal Umits Methodology Summary Description," January 1987.
8. XN-NF-80-19(P)(A), Volume 4, Revision 1, "Exxon Nuclear Methodology for Boiling Water Reactors: Application of* the ENC Methodology to BWR Reloads," Exxon Nuclear Company, Inc. June 1986.
9. XN-NF-85-67(P)(A), Revision 1, generic Mechanical Design for Exxon Nuclear Jet Pump BWR Reload Fuel," Exxon Nuclear Company, Inc.,

September 1986.

10. ANF-524(P)(A), Revision 2 and Supplement 1, Revision 2, "Advanced Nuclear Fuels Corporation Critical Power Methodology for Boiling Water Reactors,"

November 1990.

11. NE-092-001 A, Revision 1, "Ucensing Topical Report for Power Uprate With Increased Core Flow," Pennsylvania Power & Ught Company, December 1992 and NRC SER (November 30,1993).

SUSQUEHMNA UNIT 2 TRM/3.2-37 EFFECTIVE DATE 11/15/2004

PPL Rev. 3 PL-NF-03-001 Rev. 4 Page 37 of 37

12. ANF-89-98(P)(A) Revision 1 and Revision 1 Supplement 1, NGeneric Mechanical Design Criteria for BWR Fuel Designs," Advanced Nuclear Fuels Corporation, May 1995.
13. ANF-91 -048(P)(A), RAdvanced Nuclear Fuels Corporation Methodology for Boiling Water Reactors EXEM BWR Evaluation Model," January 1993.
14. XN-NF-79-71 (P)(A) Revision 2, Supplements 1, 2, and 3, Exxon Nuclear Plant Transient Methodology for Boiling Water Reactors,' March 1986.
15. EMF-1997(P)(A) Revision 0, OANFB-10 Critical Power Correlation," July 1998, and EMF-1 997(P)(A) Supplement 1 Revision 0, 3ANFB-1 0 Critical Power Correlation : High Local Peaking Results,' July 1998.
16. Caldon, Inc., TOPICAL REPORT: Improving Thermal Power Accuracy and Plant Safety While Increasing Operating Power Level Using the LEFM.'Tm System," Engineering Report - 80P, March 1997.
17. Caldon, Inc., SSuplement to Topical Report ER-BOP: Basis for a Power Uprate with the LEFM'T or LEFM CheckPlusJ System," Revision 0, Engineering Report ER-160P, May2000.
18. EMF-85-74(P)(A), -RODEX2A (BWR) Fuel Rod Thermal-Mechanical Evaluation Model,' Revision 0, Supplements 1 and 2, February 1998.
19. EMF-21 58(P)(A), Revision 0, 'Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/Microbum-B2," Siemens Power Corporation, October 1999.
20. EMF-CC-074(P)(A), Volume 4, Revision 0, "BWR Stability Analysis:

Assessment of STAIF with Input from MICROBURN-B2," November 1999.

21. NEDO-32465-A, -BWROG Reactor Core Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications," August 1996.

SUSQUEMNNA UNIT 2 TRM/3.2-38 EFFECTIVE DATE 11/15/2004

OPRM Instrumentation 3.3.9 PPL Rev. 1 3.3 Instrumentation 3.3.9 OPRM Instrumentation Configuration TRO 3.3.9 Oscillation Power Range Monitor (OPRM) supporting setpoints and settings shall be within the specified limits.

APPLICABILITY:

Thermal POWER 225% RTP ACTIONS ml, I-

1.

Separate Condition entry is allowed for each channel CONDITION REQUIRED ACTION COMPLETION TIME A.

OPRM Setpoints and A.1 Enter the condition referenced in Immediately Settings not in accordance Table 3.3.9-1 for the parameter with Table 3.3.9-1 B. As required by Required B.1 Declare affected OPRM module

-immediately Action A.1 and referenced inoperable.

in Table 3.3.9.1 C. As required by Required C.1A Restore the OPRM Setpoints and 120 days Action A.1 and referenced Settings to within the specified in Table 3.3.9-1 limits.

D. Alternate method to detect D.1 Initiate Action in accordance with Immediately and suppress thermal Conditions E, F, or G hydraulic instability oscillations required by LCO 3.3.1.3 Required Action A.3 or Required Action B.1 (continued)

SUSQUEHANNA - UNIT 2

.-- TRM / 3.3-21 EFFECTIVE DATE 11/15/2004

OPRM Instrumentation PPL Rev. 1 3.3.9 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E.

NOTE Only applicable as required by Required Action D.1 E.i Place reactor mode switch in Immediately Total core flow as a function of THERMAL the shutdown position.

POWER within Region I of the Power Flow map as specified in the COLR.

OR Total core flow as a function of THERMAL POWER within Region II of the Power Flow map as specified in the COLR and less than 50% of required LPRM upscale alarms OPERABLE F. -NOTES Only applicable as required by Required Action D.1 and when in Region II of the Power Flow map as specified in the COLR.

F.1 Place the reactor mode switch Immediately Two or more APRM in the shutdown position.

readings oscillating with one or more oscillating 210% of RTP peak-to-peak OR (continued)

SUSQUEHANNA - UNIT 2 TRM / 3.3-21 a EFFECTIVE DATE 11/1512004

OPRM Instrumentation PPL Rev. 1 3.3.9 CONDITION REQUIRED ACTION COMPLETION TIME F. (continued)

Two or more LPRM upscale alarms activating and deactivating with a period 21 second and *5 seconds.

OR Sustained LPRM oscillations >10 W/cm2 peak-to-peak with a period 21 second and *5 seconds.

G.

NOTE Only applicable as required by Required Action D.1.

Total core flow as a G.1 Initiate action to restore total core Immediately function of THERMAL flow as a function of THERMAL POWER within Region II of POWER outside of Region II.

the Power Flow map as specified in the COLR.

H.

Less than 50% of the H.1 Post sign on the reactor control 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> required LPRM Upscale.

panel that less than 50% of the Alarms are OPERABLE LPRM Upscale Alarms are

'OPERABLE.,

SUSQUEHANNA - UNIT 2 TRM / 3.3-21 b EFFECTIVE DATE 11/15/2004

OPRM Instrumentation 3.3.9 PPL Rev. 1 TECHNICAL REQUIREMENT SURVEILLANCE SURVEILLANCE FREQUENCY TRS 3.3.9.1 NOTE Only required to be met when an alternate method to detect and suppress thermal hydraulic instability oscillations is required by LCO 3.3.1.3 Required Action A.3 or Required Action B.1.

Verify total core flow as a function of THERMAL POWER is outside of Region I and 11 of the Power 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Flow map as specified in the COLR.

TRS 3.3.9.2 Perform CHANNEL CALIBRATION on each LPRM 24 months Upscale alarm 24 months TRS 3.3.9.3 Verify OPRM parameter setpoints and settings are within limits SUSQUEHANNA - UNIT 2 TRM / 3.3-21 c EFFECTIVE DATE 11/15/2004

PPL Rev. 1 OPRM Instrumentation 3.3.9 Table 3.3.9-1 OPRM SETPOINTS AND SETTINGS CQNDITIONS REFERENCE D FROM OPRM REQUIRED PARAMETER DESCRIPTION ACTION A.1 VALUE

1. TOL Period Confirmation Tolerance B

20.10 and

  • 0.30 sec
2. Ta Averaging Filter B

5 sec

3. Fc Conditioning Filter Cutoff Frequency B

1.5 Hz

4. Tmin Minimum Oscillation Period B

2 1.0 and

  • 1.2 sec
5. Tmax Maximum Oscillation Period B

2 3.0 and

  • 3.5sec
6. Noise Floor Peak Discrimination Threshold B

1

7. Minimum Cell Operability Requirement B

2 2 LPRMICell

8. Si Peak Threshold Setpoint c(a) 2 1.10 and
  • 1.20
9. S2 Valley Threshold Setpoint 0(a)

-0.85 and

- 0.95

10. Smax Max. Amplitude Trip Setpoint c(a) 2 1.30 and
  • 1.50 I1. DR3 Growth Rate Factor Setpoint c(a)

Ž 1.30 and

< 1.60

12. T1 lo SI to S2 Timer Range c(a) 2 0.3 sec
13. TI hi SI to S2 Timer Range 0(a) 2.5 sec
14. T2 lo S2 to(S3 or Smax) Timer Range c(a) 2Ž0.3 sec
15. T2 hi S2 to(S3 or Smax) Timer Range c(a)
  • 2.5 sec (a)

Applicable only when two channels in the same trip system not in accordance with Table SUSQUEHANNA - UNIT 2 TRM / 3.3-21 d EFFECTIVE DATE 11/1512004

OPRM Instrumentation PPL Rev. I B 3.3.9 B 3.3.9 OPRM Instrumentation BASES TRO The OPRM system configuration governs its operation in accordance with the licensing analysis. Several configuration parameters are intrinsic to the trip function safety setpoint bases or provide settings for defense-in-depth algorithm features that are not assumed in the basis for the protection system safety analysis (Reference 2, Reference 3).

Each of the setting values may be used as the process setpoint or device setting without further adjustment for uncertainties.

Setpoints and Settings Bases TOL Period Confirmation Tolerance The specified range of values for the period tolerance has been demonstrated to provide continuous confirmations upon transition from stable reactor operation to a growing reactor instability. A range of values is provided to allow system tuning to avoid spurious alarms on period confirmations. Limiting the setpoint adjustment range provides assurance that the Period Based Detection Algorithm will provide sufficient confirmations for a growing instability.

Ta Averaging Filter The averaging filter is used to provide a normalization of the input signal such that the average signal value is 1.0. The filter time constant is chosen to approximate the fuel thermal time constant. Setting optimizes system response during fast power transients.

Fc Conditioning Filter Cutoff Frequency The specified value for the Conditioning Filter Cutoff Frequency has been demonstrated to provide continuous confirmations upon transition from stable reactor operation to a growing reactor instability. Setting minimizes impact on signal amplitude and provides assurance that the Period Based Detection Algorithm will provide sufficient confirmations for a growing instability.

Tmin Minimum Oscillation Period Tmax Maximum Oscillation Period The Minimum and Maximum Oscillation Period parameters establish the range of detectable oscillation periods of OPRM cell signals for signal oscillations associated with reactor core thermal-hydraulic instability.

(continued)

SUSQUEHANNA - UNIT 2 TRM / B 3.3-1 8 EFFECTIVE DATE 11/15/2004

OPRM Instrumentation B 3.3.9 PPL Rev. 1 B 3.3.9 OPRM Instrumentation BASES TRO (continued)

Noise Floor The period based algorithm uses a peak detection algorithm to determine the peaks and valleys of an OPRM cell signal. The Noise Floor setting assures that peaks and valleys are effectively detected for low amplitude cell signal resonances.

Minimum LPRM/Cell This value determines the availability and resulting sensitivity of cells in the reactor core in the event of LPRM channel failures. The minimum LPRM/cell is an assumption of the OPRM trip setpoint (Sp) basis calculation.

Amplitude and Growth Rate Algorithm Parameters Si S2 Smax DR3 T1 lo T1 hi Peak Threshold Setpoint Valley Threshold Setpoint Max. Amplitude Trip Setpoint Growth Rate Factor Setooint SI to S2 Timer Ranae SI to S2 Timer Range T2 lo S2 to(S3 or Smax) Timer Range T2 hi S2 to(S3 or Smax) Timer Range These parameters calibrate the Amplitude and Growth Rate Algorithm, described in References 2 and 3, which provides an OPRM trip output to the Reactor Protection System. The OPRM design and licensing basis takes no credit for the Amplitude and Growth Rate Algorithm. The algorithm is provided as a defense-in-depth feature in the event of unanticipated power oscillations. These Amplitude and Growth Rate Algorithm Parameters are considered sufficient to provide backup protection and to avoid spurious trips by maximizing margin to expected operating conditions and transients.

ACTIONS The required actions assure that the system settings that support the Period Based Algorithm setpoint analysis, and those parameters that define the Amplitude and Growth Rate Algorithm are returned in a timely manner to the values assumed in the analysis (Reference 2, Reference 3) or that the affected channel module is declared inoperable and the applicable Required Action of LCO 3.3.1.3 is then entered, or an alternate method to detect and suppress thermal hydraulic instability oscillations is employed.

(continued)

SUSQUEHANNA - UNIT 2 TRM / B3.3-19 EFFECTIVE DATE 11/15/2004

OPRM Instrumentation B 3.3.9 PPL Rev. 1 B 3.3.9 OPRM Instrumentation BASES ACTIONS (continued)

Note I has been provided to modify the ACTIONS related to affected OPRM channels. Technical Specification Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition discovered to be inoperable or not within limits will not result in separate entry into the Condition. Technical Specification Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for affected OPRM modules and channels provide appropriate compensatory measures for separate modules and channels. As such, a Note has been provided that allows separate Condition entry for each affected OPRM channel.

B.1 Several parameter settings are essential for the proper operation of the OPRM period-based trip algorithm. The permissible values of Period Confirmation Tolerance, Averaging Filter time constant, Conditioning Filter Cutoff Frequency, and minimum operable LPRM per cell parameters are limited by the setpoint basis calculations and system transient'response analysis. The Minimum and Maximum Oscillation Period settings limit the algorithm window to the cell signal resonances that can be associated with unstable thermal-hydraulic conditions. The Noise Floor setting assures that the cell signal peak detection algorithm is sufficiently responsive to low frequency and low amplitude cell signal resonances.

Because the ability of the OPRM module to perform its safety function is affected by these parameter settings, the affected module must be considered inoperable when these conditions are not met The cell signal processing parameters within each module affects the response and operability of only that module.

Channel operability is evaluated for each inoperable module and Required Actions taken in accordance with LCO 3.3.1.3.

C.1 The design objective for the growth rate and amplitude algorithms is to provide automatic action to limit the size of these unanticipated oscillations, thereby preventing fuel cladding damage. Several parameter settings define the function of the Amplitude and Growth Rate Algorithm. The OPRM design and licensing basis takes no credit for the Amplitude and Growth Rate Algorithm, which is provided as a defense-in-depth feature in the event of unanticipated oscillations.

(continued)

SUSQUEHANNA-UNIT2 TRIVI / B 3.3-19a EFFECTIVE DATE 11/15/2004

OPRM Instrumentation PPL Rev. 1 B 3.3.9 B 3.3.9 OPRM Instrumentation BASES ACTIONS C.1 (continued)

Because the ability of the OPRM module to perform its safety function is not affected by these parameter settings, the affected module need not be immediately considered inoperable when these conditions are not met.

These parameters are to be maintained for conformance with the licensing requirement of a defense-in-depth feature in addition to the licensed OPRM trip function. This is corrected by returning the parameters to conformance within 120 days of identification.

Since the Amplitude and Growth Rate parameters within each module affect only the defense-in-depth response within each channel module, failure.to maintain the proper parameters in either module in the channel affects only the operability of that module. The trip channel requires only one operable module function, and the trip system requires only one channel for this backup function to be operable.

D.1 This Action is to be taken i the Period Based Detection Algorithm trip function is not available in accordance with LCO 3.3.1.3, and initiation of an alternate method to Detect and Suppress thermal hydraulic instability oscillations is required by the referenced LCO Required Actions. The applicable Conditions are entered as required.

E.1 As directed from Required Action D.1, this Action provides preemptive protection through Power/Flow Map operating restrictions.

When operating in Region I of the Power! Flow map specified in the COLR, or when operating in Region II of the Power / Flow map specified in the COLR with less than 50% of the required LPRM upscale alarms are OPERABLE, the potential for thermal-hydraulic oscillations is greatly increased and sufficient margin may not be available for operator response to suppress potential thermal-hydraulic oscillations. Therefore, the reactor mode switch must be immediately placed in the shutdown position. Action is taken immediately to place the plant in a condition where any potential for thermal-hydraulic instabilities will be terminated.

(continued)

SUSQUEHANNA-UNIT2 TRM / B 3.3-19b EFFECTIVE DATE 11/15/2004

OPRM Instrumentation PPL Rev. 1 B 3.3.9 B 3.3.9 OPRM Instrumentation BASES ACTIONS F.1 (continued)

As directed from Required Action D.A, this Action provides guidance for Operator action in response to thermal-hydraulic instability oscillations.

When operating in Region II of the Power/Flow map specified in the COLR immediate response is necessary when there are indications that thermal hydraulic oscillations are occurring as defined in the CONDITION.

LPRM upscale alarms are required to detect reactor core thermal-hydraulic instability events. The criteria for determining which LPRM upscale alarms are required is based on assignment of these alarms to designated core zones. These core zones consist of the level A, B, and C alarms in 4 or 5 adjacent LPRM strings. The number and location of LPRM strings in each zone assure that with 50% or more of the associated LPRM upscale alarms OPERABLE sufficient monitoring capability is available to detect core wide and regional oscillations. Operating plant instability data is used to determine the specific LPRM'strings assigned to each zone.

G.1 As directed from Required Action D.1, this Action provides guidance for Operator action in response to operation in conditions that may lead to thermal-hydraulic instability oscillations.

When operating in Region II of the Power/Flow map specified in the COLR, the potential for-thermal-hydraulic oscillations is increased and sufficient margin may not be available for operator response to suppress potential thermal-hydraulic oscillations. Therefore, action must be initiated immediately to restore operation outside of Regions II of the Power/Flow map specified in the COLR. This can be accomplished by either decreasing THERMAL POWER with control rod insertion or increasing core flow by increasing recirculation pump speed. The starting of a recirculation pump will not be used as a means to exit the excluded Regions because the starting of a recirculation pump with the plant operating above the 80% rod line is prohibited due to potential instability problems.

(continued)

SUSQUEHANNA - UNIT 2 TRM / B 3.3-19c EFFECTIVE DATE 11115/2004

OPRM Instrumentation PPL Rev. 1 B 3.3.9 B 3.3.9 OPRM Instrumentation BASES ACTIONS H.1 (continued)

The LPRMs provide a capability to monitor power in selected locations of the reactor core. The LPRM Upscale Alarm Instrumentation provides information concerning local power oscillations. Condition G requires a reactor scram when operating in Region II of the Power/Flow map specified in the COLR with indications that thermal hydraulic oscillations are occurring. The number and location of LPRM strings in each zone assures that with 50% or more of the associated LPRM upscale alarms OPERABLE any power oscillations which could occur would be detected and proper actions can be taken.

A sign is posted in the Control Room to ensure that plant operators are aware of the system condition if a plant transient results in the plant entering into the instability region.

TRS

-TRS 3.3.9.1 Required only when the OPRM trip function is not available, this TRS ensures the combination of core flow and THERMAL POWER are within required limits to prevent uncontrolled thermal hydraulic oscillations by ensuring the recirculation loops are within the limits established by the Power / Flow map specified in the COLR. At low recirculation flows and high reactor power, the reactor exhibits increased susceptibility to thermal-hydraulic instability. The Power/ Flow map specified in the COLR is based on guidance provided in References 7, 8, and 9 which also provided the guidance on how to respond to operation in these conditions. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Frequency is based on operating experience and the operators inherent knowledge of the current reactor status, including significant changes in THERMAL POWER and core flow to ensure the requirements are constantly met.

TRS 3.3.9.2 This TRS is to be performed at the specified Frequency to ensure that the LPRM Upscale Alarm Instrumentation are maintained OPERABLE.

(continued)

SUSQUEHANNA - UNIT 2 TRM / B 3.3-19d EFFECTIVE DATE 11/15/2004

OPRM Instrumentation B 3.3.9' PPL Rev. 1 B 3.3.9 OPRM Instrumentation BASES TRS TRS 3.3.9.3 (continued)

The parameter setpoint verification surveillance compares the desired settings and setpoints to the values contained in the processor memory.

This surveillance is required to assure that the settings are maintained in accordance with the setpoint analysis. The frequency is based on the OPRM CALIBRATION frequency per SR 3.3.1.3.3.

REFERENCES

1. NEDO-31960-A, BWROG Long Term Solution Licensing Methodology
2. NEDO-31960-A, Supp. 1, BWROG Long Term Solution Licensing Methodology
3. NEDO-32465-A, BWROG Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology and Reload Applications
4. CENPD-400-P-A, Generic Topical Report for the ABB Option III OPRM
5. Generic Letter 94-02, Long-Term Solutions and Upgrade Of Interim Operating Recommendations for Thermal-Hydraulic Instabilities in Boiling Water Reactors
6. LCO 3.3.1.3, OPRM Instrumentation
7. GE Service Information Letter No. 380, "BWR Core Thermal Hydraulic Stability," Revision 1, February 10, 1984.
8. Letter, L. A. England to M. J. Virgilio, 'BWR Owner's Group Guidelines for Stability Interim Corrective Action," June 6, 1994.
9. EMF-CC-074(P)(A), Volume 4, Revision 0, uBWR Stability Analysis:

Assessment of STAIF with Input from MICROBURN-B2,"

November 1999.

SUSQUEHANNA - UNIT 2 TRM / B 3.3-19e EFFECTIVE DATE 11/15/2004