ML042330486

From kanterella
Jump to navigation Jump to search
Inservice Inspection Report
ML042330486
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 08/04/2004
From: Vanderheyden G
Constellation Energy Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML042330486 (156)


Text

George Vanderheyden Vice President Calvert Cliffs Nuclear Power Plant Constellation Generation Group, LLC 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 410.495.4455 410.495.3500 Fax I

Constellation Energy August 4, 2004 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

SUBJECT:

Document Control Desk Calvert Cliffs Nuclear Power Plant Unit No. 1; Docket No. 50-317 Inservice Inspection Report Please find enclosed the Inservice Inspection Report for the Calvert Cliffs Nuclear Power Plant Unit 1.

This inspection fulfilled the intentions and requirements stated in our program plan and our commitment to comply with American Society of Mechanical Engineers Code Section XI Inservice Inspection Requirements.

Should you have questions regarding this matter, we will be pleased to discuss them with you.

Very trul our GV/CAN/bjd

Enclosures:

(1)

Calvert Cliffs Nuclear Power Plant, Inservice Inspection Summary Report for Calvert Cliffs Unit 1, ASME Boiler & Pressure Vessel Code Section XI, Form NIS-1 (2)

Calvert Cliffs Nuclear Power Plant, Inservice Inspection Summary Report for Calvert Cliffs Unit 1, ASME Boiler & Pressure Vessel Code Section XI, Form NIS-2 cc:

Mr. Craig Lowry (Without Enclosures)

J. Petro, Esquire J. E. Silberg, Esquire Director, Project Directorate I-1, NRC R. V. Guzman, NRC H. J. Miller, NRC Resident Inspector, NRC R. I. McLean, DNR 04kc7

ENCLOSURE (1)

CALVERT CLIFFS NUCLEAR POWER PLANT, INSERVICE INSPECTION

SUMMARY

REPORT FOR CALVERT CLIFFS UNIT 1 ASME BOILER & PRESSURE VESSEL CODE SECTION XI, FORM NIS-1 Calvert Cliffs Nuclear Power Plant, Inc.

August 4, 2004

NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS (As required by the Provisions of the ASME Code Rules)

Page I of 2

1. Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 (Name and Address of Owner)
2. Plant Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (Name and Address of Plant)
3. Plant Unit 1
4. Owner Certificate of Authorization (if required)

N/A

5. Commercial Service Date 05/0
6. National Board Number for Unit 2091
7. Components Inspected 811975 11 Component or Manufacturer or Manufacturer or Installer State or National Board No.

Appurtenance Installer Serial No.

Province No.

Reactor Pressure Vessel Combustion Engineering CE-67107 14000NV 20911 Pressurizer Combustion Engineering CE-67602 14000NV 20915 Steam Generator #11 Combustion Engineering CE-67504 14000NV 20922 Steam Generator #12 Combustion Engineering CE-67505 14000NV 20923 Reactor Coolant Piping Combustion Engineering N/A N/A N/A Safety Injection Bechtel N/A N/A N/A Pioinv/Suvoorts Pressurizer Spray Bechtel N/A I N/A N/A Pivinw/Suooorts I

Pressurizer Safety & Relief Bechtel N/A N/A N/A Pioine/Suovorts l

Shutdown Cooling Bechtel N/A N/A N/A Pinine/Suioorts l

Main Steam Bechtel N/A N/A NIA Pioine/Sunnorts l

Feedwater Piping/Supports Bechtel N/A N/A N/A Charging Piping/Supports Bechtel N/A N/A N/A Letdown Piping Supports Bechtel N/A N/A N/A Containment Spray Bechtel N/A N/A NIA PioinelSumoorts i

8. Examination Dates 6/19/2002 to 7/20/2004
9. Inspection Period Identification:

2002 to 2006

10. Inspection Interval Identification: 1999 to 2009
11. Applicable Edition of Section XI 1998 Addenda None
12. Date/Revision of Inspection Plan: CCNPP Units I & 2 Third Interval ISI Plan, Revision 0

NIS-1 rage OL x

13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.

The examinations reported herein constitute the sixteenth report of Inservice Inspections performed at Calvert Cliffs Unit 1, and the first report within the second inspection period of the third Inspection interval during commercial operation. The examinations for this inspection period, as required by the Third Interval Plan for Calvert Cliffs Units I& 2, were performed In accordance with the 1998 Edition of ASME Code Section Xl with No Addenda. In addition to the Section Xl required examinations we performed baremetal visual examinations of all of the Unit 1 dissimilar metal butt welds containing Ahloy 82/182 material which operate at hot leg and pressurizer temperatures in accordance with the EPRI MRP recommendations.

We also performed baremetal visual and volumetric examinations of the reactor vessel closure head in accordance with the revised NRC Order EA-03-009. See Attachment I for a list of Class 1 and 2 components examined. Nondestructive examination data and procedures are available at the plant site for review.

14. Abstract of Results of Examinations and Tests.

Surface examination of feedwater support 16-FW-1218-R3 integral attachment revealed an indication which exceeded the acceptance criteria of IWC-3512. Supplemental volumetric examinations In accordance with IWC-3512(c) verified the indication was acceptable and the depth of the indication was verified to be less than 1/32" by physical removal of the indication. Examinations of the dissimilar metal butt welds and the reactor vessel closure head were found to be acceptable with no indications of leakage.

15. Abstract of Corrective Measures.

Supplemental examinations of feedwater support 16-FW-1218-R3 found the surface Indication to be acceptable.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. ( if applicable)

N/A Expiration Date 3/ 0A Date 07/21/2004 Signed Constellation Energy By m5 f

r 1

Owner 9T* IY% tff'AVA/

CERTIFICATE OF INSERVICE INSPECTION L, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectores and the State or provinces of Maryland and employed by ABS Consulting of Houston, TX have inspected the components described in this Owner's Report during the peroid 6/2012002 to 7/20/2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owners Report in accordance with the inspection plan and as required by the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes and any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Doff-4 A.- s H4P / 4 Fot extra1z 0q&5 i) d

~ 3 pat efg Commissions A 74a; N, Is /US M ii/o National Board, State, Province, and Endorsements Date Q I TiULY a,06' N 6 17775 } /

13S

-- I --

Pae of 1 - 10 Attachment I Inservice Inspectlon Report Owner Constellation Energy, P.O. Box 1475. Baltimore, MD 21203 Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Plant Unit: 1 Owner Certifcate of Authorization (If Req.): NIA Commercial Service Date: 05/08/1975 National Board Number for Unit 20911 Summary No.

cIA 1

003625 Commenr:

003es0 Conments:

004000 Commefts:

004050 Comments:

004250 004550 Conmf:

005750 Comment:

005850 Comments:

007050 Comments:

007150 Comments:

104550 Conts:

107600 Comments:

110450 Comments:

110850 Comments:

110900 Comnrnts:

111100 Conmnenft:

Comp ID t1.4-it-0.....A.-

M4fhitAhUR" sUe C-#.-

MMn M.-l C.-.

f.*-

..v

-.

-Y......

1.

ICI BOLTING 1-64 ICI BOLTING 1-64 B-G-2 B7.10 NDE-5712-C No caUIns rnoed.

2-401D LOWER SHELL ATODEG.

B-B 92.12 NDE-5419-CC NO RECORDABLE INDICATIONS NOTED 3-401 LOWER SHELL TO LOWER HEAD B-B B2.11 NDE-5419-CC NDE-5419-CC ID GEOMETRY INDICATIONS WERE NOTED 4-404 NOZZLE TO HEAD WELDS B-0 93.110 NDE-5419-CC WILL CONSIDER SUBMIT'ING RELIEF REQUEST FOR THIS WELD BASED ON LIMITED UT COVERAGE 4-404 IRS NOZZLE INSIDE RADIUS SECTION B-D B3.120 NDE-5417-CC NO RECORDABLE INDICATIONS NOTED MANWAY STUDSINUTS 1-20 MANWAY STUDS 1-20 B9--1 B7.20 NDE-5712-CC No evIdence o boric acdd found OUTLET SIDE MANWAY STUDSINUTS OUTLET SIDE MANWAY STUDSINUTS -

NDE-5712-CC No cwable hndcaft noted INLET SIDE MANWAY STUDSrNUTS INLET SIDE MANWAY STUDSrNuTS NDE-5712-CC No rmccrdble kIdlcallo noled OUTLET SIDE MANWAY STUDSrNUTS OUTLET SIDE MANWAY STUDSNUTS -

NDE-s712.CC No Recordable Indications noted.

INLET SIDE MANWAY STUDSrNUTS INLET SIDE MANWAY STUDSrNuTS NDE-8712-CC No recordable indications noted.

30-RC-IiB-7 ELBOWTOSAFE END R-A R1.20 NDE-5710-CC No leakage noted.

30-RC-12A -10 SAFE END TO PIPE R-A R1.20 NDE-5710-CC No leakage noted 12-PSL-1 NOZZLETOSAFEEND R-A RI11 NDE-5710-CC No leakage noted 12-PSL-6 ELBOWTOPIPE R-A RI11 NDE-5412-CC NO RECORDABLE INDICATiONS NOTED 12-PSL-9 PIPETOELBOW R-A R1.11 NDE-5412-CC INDICATIONS WERE INTERMITTENT 360 DEGREES AROUND WELD 12-PSL-1 3(star)

NOZZLE TO SAFE END R-A Ri11 NDE-6710-CC No bleake noted VT CCO44V-182 Accept UT CC04-IU-018 Accept UT CC04-lU-017 Accept UT CCO44U-031 Accept UT CCo4-IU-014 Accept UT CC04-IU-032 Accept VT CCo44V-005 Accept VT CCO44V-01 I Accept VT CC044V-012 Accept VT CCO44V-013 Accept VT CC044V-014 Accept VT CC04-IV-010 Accept VT CCo4-lV-016 Accept VT CCo4-IV-0I8 Accept UT CC044U-002 Accept UT CC04-IU-02S Accept VT CCO4-IV.009 Accept 064 064 064 064 A-I 57r2004 4/22004 4J22/2004 4/27/2004 064 064 4/0/004 4/21/2004 064 064 064 U-1 A-4 U-1 A-4 U-1 A-5 064 064 064 064 064 064 064 064 U-I A-S U-1 A-4 120344004.4008 12034-004 4008 80798,120244009 60798,12024-0009 60796, 120244009 6079s,1202440009 411042004 4/11r2004 4/11/2004 4/11I2004 4/11/2004 4/13/2004 4/15/2004 4/11r2004 4/27/2004 4/27/2004 4/132004

Page of 2 - 10 Attachment I InservIce Inspection Report Owner. Constellation Energy, P.O. Box 1475. Baltimore, MD 21203 Plant Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Owner Certificate of Authorization (Hf Req.): N/A Commercial Service Date: 0510811975 National Board Number for Unit 20911 Plant UnIt: 1 Summary No.

113150 Comments:

114350 Comments:

115000 Comments:

118300 Comments:

118500 Comm~ents:

123100 Commernts:

123450 Comments:

124210 Comments:

126300 Coniments:

129750 Canments:

12l800 Commrents:

129950 Comments:

130000 Commants:

130450 Comnts:

131250 Comments:

131500 Comnts:

132150 Comments:

0Comp ID Comp Desc.

Categor! Item Procedure 12-SC-1004 - 1(star)

NOZZLE TO SAFE END R-A R1.20 NDE-5710-CC No leakage noted 12-SI-1009 -16 SAFE END TO NOZZLE R-A R1.20 NDE-5710-CC no leakage noted 12-SI-1011 -13 NOZZLE TO SAFE END R-A R1.20 NDE-5710-CC No leakage noted 4-PS-1003-2 TEETOELBOW R-A R1.11 NDE-5412-CC ID ROOT GEOMETRY WILL CONSIDER THIS WELD FOR REUEF REQUEST BASED ON LIMITED COVERAGE 4-PS-1003 -t NOZZLE TO SAFE END R-A R1.11 NDE-5710-CC No widicatlons noted 4-SR-1005 -1 NOZZLE TO SAFE END R-A R1.11 NDE-5710-CC No leakage noted 4-SR-100W-1 NOZZLE TO SAFE END R-A R1.11 NDE-5710-CC No leakage noted 2.5-SR-1004 - 2A PIPE TO PIPE R-A B9.21 NDE-5210-CC This was a presevce examisnatIon the orlgral report was filed wit the MO package.

2-CV.1003-13 PIPE TO PIPE R-A R1.20 NDE-5412-CC NO RECORDABLE INDICATIONS NOTED 2-CV-1005 - 17 ELBOW TO PIPE R-A R1.20 NDE-5412-CC WILL CONSIDER FOR RELIEF REQUEST SUBMITAL DUE TO LIMITED COVERAGE 2-CV-1005 - 18 ELBOW TO PIPE R-A R1.20 NDE4412.CC NO RECORDABLE INDICATIONS NOTED 2-CV-1005 - 21 PIPE TO PIPE R-A R1.20 NDE-5412-CC Root geometry seen intermittently 380 degrees at loe amplitudes.

2-CV-1005 - 22 PIPE TO PIPE R-A R1.20 NDE-5412-CC ROOT GEOMETRY INDICATIONS NOTED 2-CV-1005 -29 NOZZLE TO SAFE END R-A R1.11 NDE-6710-CC No leakage noted 2-DR-1003 -1A SAFE END TO PIPE R-A R1.20 NDE-5412-CC NO RECORDABLE INDICATIONS NOTED 2-DR-1004-1 NOZZLE TO SAFE END DRAIN LINES R-A R1.20 NDE-5710-CC No leakage noted 2-DR-1 008

  • 1 NOZZLE TO SAFE END DRAIN LINES R-A R1.20 NDE-4710-CC No leakage noted tUtothnot/Rhoot/F7ot Ite Cuctom Ila^ M...-

C-n n%-&-

m m p

. f l I v ~

, v o u i s

. y @ c,,

  • J %

l u,

..- c,.

a VT CCO44V-08 Accept VT CC044-v021 Accept VT CCO44V-017 Accept UT CC04-IU-029 Accept VT CC044V-004 Accept VT CC04V-022 Accept VT CC04V-023 Accept PT CC04-IP-01 I Accept UT CC04-IU-030 Accept 052 91101,9114U 052 052 084 064 064 064 0t4 041 041 041 041 041 041 064 084 064 91100 91 100SH0003 91099SH0002 91099SH-t002 91098SH0002 91098SHOOOI0 91098SHOOOI FSK-MP-490 FSK-MP-492 FSK(-MP-492 FSK-MP-492 FSK-MP-492 FSK-MP-492 FSK-MP-575, -5i5H FSK-MP"1053..053H FSK-MP-1006, -lOO0GH-4/10/204 414/2004 4/15/2004 412712004 4/10/2004 411/2004 418/r2004 4/23/2004 v=004 4V17/2004 4117/2004 4/17/2004 4117/2004 4114/2004 411/204 4112/2004 4114V2004 UIT CCO44-.1-012 UT CCO44IU.013 UT CC04-IU-033 LT CC04"U-035 VT CC044IV.020 Accept Accept Accept Accept Accept UT CC044U-036 Accept VT CCO4-r008 AcCept VT CCo4-4V-019 Accept

Page of 3 - 10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Plant Unit: 1 Owner Certificate of Authorization (Hf Req.): N/A Commercial Service Date: 05/08/1975 National Board Number for Unit: 20911 C

---,,o V

I

  • U
f.

~In r-~nn rfl-132450 2-DR-1007 -

Comments:

No leakage noted NOZZLE TO SAFE END DRAIN LINES 133200 Comments:

133250 Conaents:

11A-1 INTEGRAL ATTACHMENT RCP-I IA NO RECORDABLE INDICATIONS NOTED 11A-2 INTEGRAL ATTACHMENT RCP-1 1A NO RECORDABLE INDICATIONS NOTED Categ R-A B-K B-K B--2 or Iem Procedure R1.20 NDE-5710-CC 810.30 NDE-210-CC B10.30 NDE-5210-CC 87.60 NDE-5712-CC 87.60 NDE-5712-CC B7.60 NDE-5712-CC B7.60 NDE-5712-CC 133500 11A-C-I THROUGH 1e Comments:

No recodble indications noted RCP-1 1A SEAL BOLTING 134050 Comments:

134600 Commns:

135150 Comments:

135235 Comments:

135240 Comments:

136150 Commvenls:

136200 Comments:

136250 Comments:

136300 Commnts:

136450 Commns:

136500 Comments:

136550 Co aments:

136600 Comments:

136650 Comments:

118-C-1 THROUGH 16 No recordable indications noted 12A-C-1 THROUGH 16 No recordable indications noted 128C01 THROUGH 16 No ecordble IIdtions noted I-CV-100F1I No recordable ndiations noted.

1-CV-100F-2 No recordable Indications noted.

1-MOV-614 ON 12-S-1009 No material loss. No signs d Boric Abd 1-MOV-424 ON 12-S1010 No recordable indications noted 1-MOV-634ON 12-SI-1011 No recdable Indications noted 1-MOV-644 ON 12-S11012 No recordable indications noted 1-MOV-403 ON 2.5-SR-1003 No recordable indications noted.

1-MOV-405 ON 2.5-SR-1004 No recordable Indication noted I-CV-517 ON 2-CV-1003 No recordable indictions noted 1-CVC-3ss ON 2-CV-1003 No bolting on this valve.

1-CVC-165 ON 2-CV-1003 There was no bdlti assocated wift gim RCP-118 SEAL BOLTING B--2 RCP-12A SEAL BOLTING B--2 RCP-12B SEAL BOLTING B--2 PRESSURIZER SPRAY VALVE LOWER B-M-i PRESSURIZER SPRAY VALVE UPPER B-M-I VALVE BODY BOLTING B--2 812.30 812.30 87.70 VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BOOY BOLTING VALVE BODY BOLTING W-0-2 87.70 B--2 87.70 B-0-2 B7.70 B-0-2 87.70 B-0-2 B7.70 NDE-5210.CC NDE-210-CC NDE-s712-CC NDE-5712-CC NDE-5712-CC NDE-571 2-CC NDE-5712-CC NDE-5712-CC NDE-5712-CC NDE-5712-CC NDE-4712-CC Method/Sheet/Results VT CCO44V-07 Accept PT CC04-IP-020 Accept PT CCU4-IP.021 Accept VT CC04-IV-OfO Accept VT CCO4-IV-081 Accept VT CC044V-04 Accept VT CC04-IV-3 Accept PT CC04-IP-002 Accept PT CC04-IP-003 Accept VT CCU4-IV-038 Accept VT CCo4-V-039 Accept VT CCO4-IV-040 Accept VT CC04-lV-031 Accept VT CCO44V-030 Accept VT CCU4V-065 Accept VT CC04-IV-034 Accept VT CCU44V-033 Accept VT CCO-V-032 Accept 064 064 064 064 064 052 052 052 052 064 064 041 041 System 064 064 064 064 91099SHOO02 91099SHOO02 91100 91100SH10002 91100SHOD03 91 100SHOO04 91098SH0002 91093SHooo1 FSK-MP-490 FSK-MP-490 ISO Num FSK-MP-507 A-33 A-33 Exam Date 4/12/2004 4/22/2004 4/22/2004 4Rn2004 4/27/004 4/27/2004 4/27/2004 4/27/2004 4/15/2004 4/15/2004 4/15/2004 4/20/04 4/27/2004 4/2712004 4/20/2004 4/2ot20014 B--2 B-0-2 B--2 87.70 87.70 B7.70 041 FSK-MP-490

Page of 4 -10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway. Lusby, MD 20657 Plant Unit: 1 Owner Certificate of Authorizatlon (If Req.): N/A Commercial Seovtce Date: 05/08/1975 National Board Number for Unit: 20911

.e.

Immns txrs rmnI

n.

r..

'1mmd C

'u.

vum*,u *F wwVU.C.

13M850 Comments:

137100 Comments:

137200 Comments:

137250 Coaments:

137300 Comments:

13785O Comments:

137700 Conts:

137750 Comments:

137800 Commentt:

137t)0 Coments:

137900 Conts:

137950 Comments:

138000 Comments:

138050 comments:

138100 Comments:

138630 Comments:

138840 Cots:

1-CVC-392 ON 2-CV-1005 No valve bolting on tis valve.

1 -CV-515 ON 2-1004 No recordable dications noted 1-CV-516 ON 2LD-1I002 No recodble Indcatiors noted 1-CV-518 ON 2-CV-1004 No recordable indications noted 1-CV-519 ON 2-CV-1005 No recordable InlIcatons noted 1-1-217 ON 12-SI-1009 No reco ble ndications noted 1-SI-227 ON 12-SI-1010 No rewbdb indictin noted 141-247 ON 12-S1-1012 No recordable indications noted.

141-237 ON 12-S1-1011 No redable Indlicatons noted 1-MOV-651 ON 14-SC-1004 No Indications noted.

1-MOVW-ON 12-SC-1004 No recordable indications noted 11-5-118 ON 8-81-1001 No recordable Indications noted 141-128 ON "81-1002 Sliht cornelon. no materdal Ioss noted 1-41-138 ON t-S1-1003 No recordable Indications noted 1-51-148 ON 8-51-1004 No recordable Indications noted 2.5-SR-1007 - 2FB No recoable IdctIons noted 2.5-SR-1008 - 2FB No indications noted VALVE BODY BOLTING VALVE BODY BOLTING VALVE BOGY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BODY BOLTING VALVE BOGY BOLTING VALVE BODY BOLTING INLET FLANGE BOLTING INLET FLANGE BOLTING Categorw item Procedure B-G-2 87.70 NDE-5712-CC B4--2 B7.70 NDE-5712-CC B-G-2 B7.70 NDE-5712-CC B-C-2 B7.70 NDE-5712-CC B-G-2 B7.70 NDE-5712-CC B4--2 87.70 NDE-5712-CC B-G-2 B7.70 NDE-5712-CC B-G-2 B7.70 NOE-5712-CC B-0-2 07.70 NDE-5712-CC BG-2 87.70 NDE-5712-CC 8-G-2 87.70 NDE-4712-CC BG-2 B7.70 NDE-5712-CC B-4-2 87.70 NDE-5712-CC B4--2 B7.70 NOE-5712-CC B-0-2 B7.70 NDE-5712-CC B4--2 87.50 NDE-5712-CC B--2 B7.50 NDE-5712-CC Ijathk,.AIh910a

.4.

11lOIRI1B7X:

1-il[

V

.1II

-7li.....

.l VT CC04-4V-088 Accept VT CC04-IV458 Accept VT CCO44V-059 Accept VT CC04-IV-041 Accept VT CC04-IV-042 Accept VT CCO44V-078 Accept VT CC04-V-079 Accept VT CCO44V-080 Accept VT CC04V-081 Accept VT 2004BV028 Accept VT CCO44-V82 A-t VT CC04-IV-043 Accept VT CC044V-089 Accept VT CC04-IV-070 Accept VT CC044V-038 Accept VT CC044V-87 Accept VT CC044V-088 Accept Otlatam IMC Mt,,n, I=am fat.

041 FSK-MP-492 041 041 041 041 052 052 052 052 052 052 052 052 052 052 084 084 FSK-MP-455. -458 FSK-MP-455, -456 FSK-MP-401 FSK-MP-492 91100 91100SHO002 91`1008HC0004 911005H0003 91101.91148 91101.91146 91100 91 1005t10002 911008110003 911005H0004 910985H0002 91098SHOI01 4/15/2004 4/27/2004 412712004 4/15r2004 4/1512004 4/2012004 412012004 4/27/2004 4/27/2004 3/1/2004 4/27/2004 4/1512004 4/15/2004 4/1152004 4/202004 4/27/2004 4/2712004

Page of 5-10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Plant: Calvert Cliffs Nuclear Power Plant. 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Plant Unit: I Owner Certificate of Authorization (f Req.): N/A Commerclal Service Date: 05108/1975 National Board Number for Unit: 20911 Summary No.

138650 Commns:

138750 Co Tfens:

138850 Commnts:

1389!0 Conf 139050 Conms:

139150 Cons:

139250 Convnrt 600250 Comrents:

eos550 Cornffs:

605350 Comment:

605400 Comments:

605600 Comnna:

605650 Comma:

Conrsef:

806850 Convients:

606700 Comma:

Comp ID Comp Desc.

Catl PRESSURE RETAINING COMPONENT REACTOR PRESSURE VESSEL B-P No Indications noted PRESSURE RETAINING COMPONENT PRESSURIZER B-P No IndlcatIons noted.

PRESSURE RETAINING COMPONENT STEAM GENERATORS B-P No Indications noted.

PRESSURE RETAINING COMPONENT HEAT EXCHANGERS B-P No IrndIatIons noted.

PRESSURE RETAINING COMPONENT PIPING B-P No Indications node.

PRESSURE RETAINING COMPONENT PUMPS B-P No indIcations noted.

PRESSURE RETAINING COMPONENT VALVES B-P Minor packg leakage noted on several valves corecled on fte spot under IR4

-95.

12-PSL - H-1 COMPONENT SUPPORT F-A No.lcorabe Indications 3-PS-1001 - H-12 COMPONENT SUPPORT F-A NO RECORDABLE INDICATIONS NOTED 2-L-l1004 - R-4 (144-35)

COMPONENT SUPPORT-SNUBBER F-A No recordable Inicatons noted 2-LD-1004 (1-64-31)

COMPONENT SUPPORT-SNUBBER F-A No recordable indicatom noted.

2-CV-1003 - H-28, R-32 CONPONENT SUPPORT F-A NO RECORDABLE INDICATIONS NOTED 2-CV-1003 - H-27, R-33 CONPONENT SUPPORT F-A NO RECORDABLE INDICATIONS 2-CV-1005 - R-13, R-14 COMPONENT SUPPORT F-A No relevant conditions noted.

2-CV-1005 - R-17 COMPONENT SUPPORT F-A Examination folIlowrg bed removal revealed no recorable Indications.

2-CV-1005 - R-15, R-18, H-12 COMPONENT SUPPORT-SNUBBER F-A ExamInation foalng bead removal revealed no recordable Idications.

egon kRem B15. 10 615.20 B15.30 B15.40

=

Procedure NDE-5710-CC NDE-5710-CC NDE-5710-CC NDE-4710-CC C.Ctm AC0 Mi,...

rc-n.f PVIUL IuonUIvWQUS

Jfl~m l-I S.0.,

ualJ B15.50 NDE-5710-CC B15.60 NDE-5710-CC B15.70 NDE-5710-CC FIOC NDE-5711-CC FI.IA NDE-5711-CC F1.10C NDE-5711-CC FIOC NDE-5711-CC F1.10B NDE-4711-CC F1.108 NDE-5711-CC F1.108 NDE-5711-CC F1.10B NDE-5711-CC NDE-571 1-CC Fi1OC NDE-5711-CC NDE-571 1 -CC VT CC04-IV-164 Acce-t VT CC044V-165 Accept VT CCO44IV-166 Accept VT CC044V-167 Accept VT CC044V-168 Accept VT CC04-1V-169 Accept VT CC04-IV-170 Accept VT CCO4-4V-050 Accept VT CCO4-V-04 2 Accept VT CCo4-4V-180 Accept VT CC04-IV-181 Accept VT CC04-IV-057 Accept VT CC04-4V-05 Accept VT CC04-NV-027 Accept VT C004V-l18S Accept VT CC04-NV426 Info VT CC04-V-184 Accept VT CCO44V-025 Info 06A 064 064 064 064 052 041 064 052 041 064 064 041 041 041 041 041 041 041 041 041 8072SHO1OO 607295HO001 80729SHo1OO 607295H0001 60729sHooo1/ 60730 60731 607295H0001 60730 & 60731 12024-9 REV 11 910995H0001. SH0002 FSK-MP-455, -456 FSK-MP-455, -456 FSK-MP-490 FSK-MP-490 FSK-MP-492 FSK-MP-492 FSK-MP-492 FSK-MP-492 FSK-MP-492 Y712004 57/2004 Y7/2004 57/2004 57/2004 5/7/2004 5/7/2004 4/23/2004 40/2004 4/19/2004 4/19/2004 427/2004 471274004 51/2004 511/2004 4/22a2004 5/1/2004 416/2004

Page of 6 -10 Owner Conste Plant: Calvert i Plant Unit: 1 ummary No.

Ca Comments:

607900 607950 Comments:

eosooo Comments:

Comments:

808075 Comments:

Cf:

soso8s Comments:

eilation Energy, P.O. Box 1475, Baltimore, MD 21203 Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway. Lusby, MD 20657 Attachment I Inservice Inspection Report Owner C Commer National ertificate of Authorizatlon (If Req.): N/A cia!l Sevice Date: 05/08/1975 Board Number for Unit 20911 System ISO Num Ex 041 FSKXMP-492 041 FSK-MP-492 CopID Corrp Desc.

Categor Item Procedure Method/Sheet/Results 2-CV-1005-H-14 COMPONENT SUPPORT F-A F1.10B NDE-6711-CC VT CCO4-4V-186 Accept NDE-571 1-CC VT CCO4tV026 Info R-xaminaton lai lad removal revealed no recbe Indications.

11A-ISC COMPONENT SUPPORT F-A F1.40C NDE-5711-CC VT CC04-tV-044 Info This examination was not completed measreent need to be taken to verify the loedaig on the sprin cans. Exam will be remseduled to verify cods.

11A-2SC COMPONENTSUPPORT F-A F1.40C NDE-5711 -CC VT CC04-V-045 Info This examination was not completed messmrements need to be taken to verity the eading on the spring cans. Exam wit be rescheduled to verity beds.

IIA-3SC COMPONENT SUPPORT F-A F1.40C NDE-5711 -CC VT CC04-IV-048 Info This examination was not completed measurements need to be taken to verify the oading on the spring cans. Exam witl be rescheduled to verify loads.

IIA-4SC COMPONENT SUPPORT F-A F1.40C NDE-5711 CC VT CCO4-V-047 Info This examination was not completed measurement need to be taken to verify the loading on the sprng cans. Exam wit be rescheduled to verify beds.

14496 COMPONENT SUPPORT F-A F1.40C NDE-5711-CC VT CCC4-V-049 Accept NO RECORDABLE INDICATIONS NOTED 1-44-097 COMPONENT SUPPORT F-A F1.40C NDE-5711-CC VT CC04NV-048 Accept NO RECORDABLE INDICATIONS NOTED am Date 5/1/2004 4/2/00 064-B 064-B 4r23Q004 4/23/2004 064-084-B 0848 4/23J2004 4/23/2004 4/3/2004 Class 2 252275 Comments:

300400 Comments:

300850 Comments:

301800 Comments:

307200 Comments:

309650 Comments:

SCHE-11-SI INTEGRAL ATTACHMENT C-C C3.10 NDE-5110-CC MT CC04-lM-001 Accept 052 72% coverage due to obstructions. Consider for relef request submittal. No rewdable indications 2441-1201-4 ELBOW TO PIPE R-A R1.20 NDE-5412-CC UT 20046U002 Accept 052 91097SH0012 NDE-5210-CC PT 2004BP01 I Accept 052 91097SH0012 No recordabe Indict noted 24-SI-1201 - R-7 INTEGRAL ATTACHMENT C-C C3.20 NDE-5210-CC PT 2004BP017 Accept 052 91097SH0012 NDE-5210-CC PT CC04-IP-22 Accept 052 91097SH0012 INITIAL EXAM IDENTIFIED WELD SPATTER AND AN ARC STRIKE WHICH INTERFERED WITH COMPLETION OF THE EXAM FOLLOWUP EXAM HAD NO RECORDABLE INDICATIONS.

24-SI-1202-H-22 INTEGRAL ATTACHMENT C-C C3.20 NDE-5210-CC PT CC04-IP-001 Accept 052 91097SH0013 418/2004 24/2004 2/4/2004 2/2t2oo4 6e30n2004 3/18N2004 3/25no4 3/15/2004 No recordable Indications noted 14-SI-1201 - 2 ELBOW TO PIPE NO RECORDABLE INDICATIONS NOTED 12-SI-1213 -4 PIPE TO ELBOW NO RECORDABLE INDICATIONS NOTED R-A RI.20 NDE-5412-CC UT CC04-IU-001 Accept 052 R-A RI.20 NDE-5412-CC UT CC044U-003 Accept 052 91097SH0011, SH0013 91097SH0001 91097SH0026, 91166, 91109 311300 12-SI-1214 - 22 PIPE TO ELBOW Comments:

Previousy recorded IndICation bs not recodabe under current Code.

R-A RI.20 NDE-5412-CC UT 20048U018 Accept 052 3/101204

Page of 7 - 10 Attachment I Inservice Inspectlon Report Owner Constellation Energy, P.O. Box 1475. Balimore, MD 21203 Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway. Lusby, MD 20657 Plant Unit: I Owner Certificate of AuthorizatIon (1f Req.): N/A Comrnercial Service Date: 05108/1975 National Board Number for UnIt 20911 Summary No.

312250 Comments:

333550 Conmnets:

333900 Comments:

3388 Comnents:

339350 Comments:

403350 Comments:

403400 Comments:

403550 Comments:

403650 Comments:

408550 Comments:

408950 Comments:

412950 Comments:

413000 Comments:

413100 Comments:

Camp ID Camp Desc.

Cater Item 12-SI-1216-1 TEE TO PIPE R-A R1.20 Consider for relW request due to lited wverage on UT. No recordeble ndications noted.

6-SI-1217-3 ELBOWTOPIPE R-A RI.20 NO RECORDABLE INDICATIONS NOTED.

8-S1-1217-9 PIPETOELBOW R-A R1.20 No IndIcatIons Noted 4-5-1209-1 BRANCH CONNECTION TO ELBOW R-A R1.20 Relief Request reguired due to only 50% coverage.

4-SI-1209 -10 ELBOW TO PIPE R-A Ri.20 UT exim coverage kilted to 91.5% due to loss of contact on hItradose od etbow.

8-CS-1205 -3 PIPE TO ELBOW R-A R1.20 NO RECORDABLE INDICATIONS NOTED 8-CS-125 -4 ELBOW TO ELBOW R-A R1.20 NO RECORDABLE INDICATIONS NOTED 8CS-1205-8 PIPE TO ELBOW R-A R1.20 NO RECORDABLE INDICATIONS NOTED 8-CS-1205 -8 PIPE TO ELBOW R-A R1.20 No Indications Noted 8-CS-1 206 - 20 PIPE TO ELBOW R-A R1.20 ID GEOMETRIC INDICATIONS NOTED 8-CS-1206 - 27 ELBOW TO PIPE R-A R1.20 No recordable hIdications noted.

14-SC-1203 -28 PIPE TO TEE R-A R1.20 No Indcations Noted 14-SC-1204 -1 TEE TO PIPE R-A R1.20 No Indications Noted 14-SC-1204 -2 PIPE TO ELBOW R-A R1.20 ID Root Geometry noted. No recordable idictions noted.

Procedure NDE-5210-CC NDE-5412-CC NDE-5412-CC NDE-5412-CC NDE-5210-CC NDE-5412-CC NDE-5412-CC NDE-5210-CC 154kAIftkaaa.,

.J4.

P.vetFm IMCM MI...m Cn-P%.,

-Y*IH%-flJfl USWUU O.U

  • -JJ

-*1I t.Anl JOIUd PT 2004BP015 Accept 052 91097SH000, 91110 UT UT UT PT UT UT PT 2004BL1003 Accept 20048U014 Accept 2004BU019 Accept 2004BP012 Accept 2004BU1005 Accept 20048U001 Accept 2004BP013 Accept 052 052 052 91097SH0006, 911 10 91110 91110 NDE-5412-CC UT 2004BU024 Accept NDE-412-CC UT 2004BU025 Accept NDE-5412-CC UT 2004811028 Accept NDE-5412-CC UT 2004BU020 Accept 052 91169 052 91169 052 91189 052 91189 91172, 910975H0002, 081 91145 91172, 91097SH0002.

081 91145 91172. 91097SH0002.

081 91145 91172, 91097SHtO02.

051 91145 051 910975H0007, 91173 051 91097SH0007, 91173 061 91097SH0007,91173 051 91097SH0007, 91173 081 91097SH0007, 91173 91097SH0011, 91166.

052 91148 052 91097SH0001 052 91097SH0001 2ten20o4 2/6rA4 3/4/2004 3t10t2004 2tsnoo4 2t/U2004 2t/U2004 21562004 3/16/204 3/16U2004 3/1U/2004 3/11/2004 513t2004 5/Y2004 3/4/2004 217/2004 2tet2004 3/12/2004 3/122004 3NV2004 NDE-5412-CC NDE-5210-CC NDE-54 12-CC UIT CC04-IU1-034 Accept PT CC04-IP-019 Accept UT 2004BU012 Accept NDE-5412-CC UT 20048U004 Accept NDE-5210-CC PT 2004BP014 Accept NDE-5412-CC NDE-5412-CC NDE-5412-CC UT UT UT 2004BU021 Accept 20048U022 Accept 2004811015 Accept

Page of 8 - 10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway. Lusby, MD 20657 Plant Unit: 1 Owner Certificate of Authorization (If Req.): N/A Commercial Service Date: 05/08/1975 National Board Number for Unit 20911 Summary No.

ComD ID Como Desc.

413150 Conments:

417200 Contents:

417950 Come:

419150 Commt :

421400 Comments:

422350 Commnts 422400 Contnents:

422450 Comment:

422500 422550 Commiens:

433500 Comment:

433550 orrnfents:

14-30-1204 - 3 ELBOW TO ELBOW ID Root Geometry noted. No reordable idlctnws noted.

10-SC-1214-1 TEE TO PIPE Wi consider for relief request due to UT coverage.

10-SC-1214 -13 ELBOW TO PIPE NO RECORDABLE INDICATIONS NOTED

-SC-1206S 1A PIPE TO ELBOW NO RECORDABLE INDICATIONS NOTED.

1/64RV-3993 BRANCH CONNECTION To be considered for relief quest due to coverage.

18-IRV-4001 8-IN. BRANCH CONNECTION Wll consider for relIef request due to UT coverage.

1-WRV-4002 8-IN. BRANCH CONNECTION WI consider for ree request due to UT coverage.

1/8-RV-4003 8-IN. BRANCH CONNECTION WM consider for relief request due to UT coverage.

1/-RV4004 t-N. BRANCH CONNECTION WN consider for rele request due to UT coverage.

1/8-RV-4005 8-IN. BRANCH CONNECTION Wil consider for relief request due to UT coverage.

18-FW-1218 - R-3 INTEGRAL ATTACHMENT Categor! Item Procedure R-A R1.20 NDE-4412-CC R-A R1.20 NDE-5412-CC R-A R1.20 NDE-5412-CC R-A R1.20 NDE-5412-CC C-F-2 HELB NDE-s IO-CC NDE-541 1-CC AUGMT HELB NDE-5110-CC NDE-541 1-CC AUGMT HELB NOE-110-CC NDE-5411-CC AUGMT HELB NDE-5110-CC NDE-541 1-CC AUGMT HELB NDE-51 10-CC NDE-6411 -CC AUGMT HELS NDE-51 10-CC NDE-541 1 CC C-C C3.20 NDE-5110.CC Method/Sheet/Results UT 2004BLt1J1 Accept UT 2004BU017 Accept UT CC04-IU-004 Accept UT 2004BU013 Accept MT CCO4-4M-008 Accept UT CC04-1U-021 Accept MT CC04-IM-OOS Accept UT CC04-1L-022 Accept MT CC04-IM-007 Accept UT CC04-lu-020 Accept MT CC04-IM-004 Acceot UT CCO44U-019 Accept MT CC04-IM-003 A-cet UT CCo44U-024 Accept MT CC04-IM-02 Accept UT CCO44tU-023 Accept MT CC04-IM-010 Accept 052 91097SHW0t 3/8/2004 System ISO Num Exam Date 052 052 052 083 083 083 083 083 083 083 083 083 083 083 083 045 91097SH0001, SHOO05 91097SH0001. SHODOS 91097SH001 1 60345SHO001 80345SHDD01 80345SHW001 80345S3t1tO1 f0345SHD001 80345SHo001 80345SHD100 80345SHDC01 I0345SHC001 80345SHW01 f0345SHC001 60345SHW01 91093 3/412004 312412004 3/4/2(04 4/17/2004 4123P2004 4/1712004 4/23/2C04 4/17/2004 4/23/2004 4/17/2004 4/23/2004 4117/2C04 4123R004 4/2312004 41282004 4/2212004 4/282004 4/21/2004 4/1312004 NDE-5413-CC UT CCO44U-018 Accept NDE-5403-CC UT CC04-IU-037 Info 045 91093 045 91093 NDE-5110-CC MT CC04-IM-4S Reject 045 91093 The rejectable surface ndcation was found to be acceptable using supplemental vdlunet techraiques and the depth was verified to be less than 1/32 by physical removal of the hflicaton.

18-FW-1218 -8 PIPE TO PIPE R-A R1.20 NDE-8411-CC UT CC044U-010 Accept 045 91093 ID ROOT GEOMETRY INDICATIONS NOTED 038 041 045052 C-H C7.10 NOE-5710-CC VT CC044V-171 Accept 083 VARIOUS 567J2004 436050 PRESSURE RETAINING COMPONENT SYSTEM LEAKAGE TEST Conments:

No hnications noted.

Page of 9 -10 Inseivice Inspecton Report Owner Constellation Energy, P.O. Box 1475. Baltimore, MD 21203 Plant Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby. MD 20657 Plant Unit: 1 Owner Cerifcate of Authorization (1f Req.): N/A Commercial Service Date: 05/08/1975 National Board Number for Unit: 20911 e,

-mmo bln^m I----

fl-.-.

N-t -

t 0

P 1-s ti^kAIeka*0.

.1t.

Reon Un, C.m nnf*

VWU...IIItaly Ulu.

t~~il L,*IUO.

~Ilat WU-.n s If uu ivo m.*-.ous JYII I,

LS!aO C-H C7.30 NDE-5710-CC 436150 PRESSURE RETAINING COMPONENT PIPING Comments:

No Indications vioted.

436250 PRESSURE RETAINING COMPONENT PUMPS Comments:

No indications noted VT CC04-iV-172 Accept PRESSURE RETAINING COMPONENTS VARIOUS PRESSURE RETAINING COMPONENTS VARIOUS 5Y7/2004 Y712004 C-H C7.50 NDE-5710-CC VT CC044V-179 Accept 436350 Comments:

700900 Comments:

701000 Comments:

701250 Comments:

701450 Comments:

704450 Cormenns:

704750 Comments:

708250 Comments:

701550 Comments:

711700 Comments:

711750 Comments:

717850 PRESSURE RETAINING COMPONENT VALVES C-H No Indications noted.

SCHE-1 1-S1 COMPONENT SUPPORT F-A No recordable indications noted.

SCHE4-12-51 COMPONENT SUPPORT F-A No recordable Indications noted.

24-SI-1001 - R-7 COMPONENT SUPPORT F-A The as found condits were accepted in accordance with ES200400128 Supp No. 000.

24-SI-1202 - H-22 COMPONENT SUPPORT F-A NO RECORDABLE INDICATIONS NOTED 12-SI-1004 - H-2 COMPONENT SUPPORT F-A No recorble hdlone noted 10-SI-1002 - R-12 COMPONENT SUPPORT F-A No Recordable indications 6-5I-1010-H-3 COMPONENT SUPPORT F-A Issue Report 3R4-09-424 was witten to evaitate the as found conditions. ES200400221 6-SI-1012 - R-2 COMPONENT SUPPORT F-A No recordable Indications noted 4-SI-1208-H-11,R-9 COMPONENT SUPPORT F-A No recordable ndiations noted.

4-51-1208* H-10, R-8 COMPONENT SUPPORT F-A NO RECORDABLE INDICATIONS NOTED 2-SI-1226 -S-1 COMPONENT SUPPORT F-A C7.70 F1.40B F1.40B F1.20B F1.20A NDE-8710-CC NDE-571 1-CC NDE-5711 -CC NDE-5711-CC NDE-571 1-CC VT VT VT VT VT CCO4-IV-174 Accept CC04-iV-183 Accept 2004BV004 Accept 2004BV003 Accept 2004BV034 Accept PRESSURE RETAINING COMPONENTS VARIOUS 052 B-3/ 12015-0012 052 052 052 F1.20B NDE-5711-CC VT CC04-iV-073 Accept 052 F1.20B NDE-5711-CC VT CC04-iV-001 Accept 052 F1.20A NDE4711-CC VT 2004BV025 Reject 052 Supp No. 0 accepted fe as found condition and directed the drawins to be dianged.

F1.20A NDE-5711-CC VT 2004BV024 Accept 052 F1.206 NDE-5711-CC VT 20049V028 Accept 052 F1.20B NDE-5711-CC VT CC04-iV-071 Accept 052 F1.20B NDE-4711-CC VT 2004BV016 Accept 052 91097SH0012 91097SH0013 91097H0026. 911it, 91109 91097SHo0026 91143, 91100SH0001 91144, 9i 100SH0002 91097SH0016, SH0017 91097SH0016, SH0017 FSK-MP-432 5t7/2004 7/2at2004 2/9N2004 2/2/2004 3/1S/2004 3/10/2004 329/2004 3/1/2004 3112004 3V412004 3/25/2004 2t24/2004 Comments:

No recordable hidications noted.

717900 2-SI-1228 - S-2 COMPONENTSUPPORT F-A F1.20B NDE-571I-CC VT 2004BV017 Reject 052 FSK-MP-432 2124/2004 Comiments:

Issue Report IR4409-422 was written to evaluate the as found conditions. ES200400154 Supp No. 0 evaluated the as found conditors and found hem to be acceptable and directed the dawing to be updated to relet the as beit conditions.

717950 2-S1-1226 - S-3 COMPONENTSUPPORT F-A F1.20B NOE-711-CC VT 2004BV018 Accept 052 FSK-MP-432 2124/2004 Comments:

Issue Report # IR4-009421 was written to evaluate the as found condtions. ES200400154 SUp, No 0 evauated the as tound conditions end found thm to be acceptable and directed the dawing to be updated to refec the as butt conditions.

718300 S-CS-1203 - R4 COMPONENT SUPPORT-SNUBBER F-A F1.20C NDE-5711-CC VT 2004BV002 Accept 061 91097SH0005 2N9/2004 Comments:

Concrete damage is noi servce Induced. No rewdable indications noted.

Page of 10 -10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Plant Unit: 1 Owner Certificate of Authorization (H1 Req.): NIA Comrnmerclal Service Date: 05108/1975 National Board Number for Unlt 20911 Summary No. ComD ID Como Desc.

718800 Comments:

721550 Comments:

721950 Comments:

722300 Comrents:

722750 Comments:

723500 Comments:

725750 Comments:

725800 Comments:

725950 commets:

8-CS1205 -H4-5, R4 COMPONENT SUPPORT Cleafances found weto acceptable h accordance with ES-02.

14-SC-1203 - A-270 COMPONENT SUPPORT No recordable Idications noted.

14-1204 - H4-5, R-4 COMPONENT SUPPORT SOME MINOR COATINGS DAMAGE ON RESTRAINT NOTED 14-SC-1204 - R-1 COMPONENT SUPPORT No rable Idlostous 12-SC-1200 - H4 COMPONENT SUPPORT NO RECORDABLE INDICATIONS NOTED 10-SC-1214 - H4-8.

R-7 COMPONENT SUPPORT NO RECORDABLE INDICATIONS NOTED 34-MS-1204 COMPONENT SUPPORT-vARIABLE NO RECORDABLE INDICATIONS NOTED 34-MS-1204 - R-e COMPONENT SUPPORT NO RECORDABLE INDICATIONS NOTED 34-MS-1205 1 COMPONENT SUPPORT-VARIABLE NO RECORDABLE INDICATIONS NOTED Catego Item Procedur F-A F1.20A NDE-4711 -CC F-A F1.20B NDE-5711-CC F-A F1.20A NDE-5711 -CC F-A F1.20m NDE-5711-CC F-A F1.20B NDE-5711-CC F-A F1.20B NDE-571 1-CC F-A F1.20C NDE-5711-CC F-A F1.20B NDE-4711-CC F-A F1.20C NDE-5711-CC F-A F1.20B NDE-57i1-CC Method/Sheet/Results System ISO Num Exam Date VT 2004BV033 Accept VT 2004BV001 Accept VT 2004BV031 Accept VT rC04-4V402 Accept VT CC04V-072 Accept VT CC4-IV-003 Acct VT CCO44V-075 Accept VT CC04-rIv-76 Accept VT CCo4-IV-077 Accept VT CCU 4-IV-415 Accept 061 91172, 91097SHOO02. 91 052 052 052 052 052 083 063 083 063 91097SHDO11, 91166. 91 91097SH0001 910975H0001 91097SHOO02, SH1OWS 91097SH6001, SHOD0s 603455sH000 60345SH0001 80345SH0001 eO345SHOO01. SH0002 3/16/2004 2N/2004 3/6/2004 3/29/2004 3/25/2004 3/18/2004 4119/2004 4R0/2034 4/19/2004 419/2004 726e00 6-MS-1208 - R-2 Comments:

No nc ble Indlcations.

COMPONENT SUPPORT 727200 16-FW-1218 - R4 Comments:

No recordable indications.

COMPONENT SUFPORT-SNUBBER F1.20C NDE-5711-CC VT CCO4IV-037 Accept 045 91M 4/21rdOO4

ENCLOSURE (2)

CALVERT CLIFFS NUCLEAR POWER PLANT, INSERVICE INSPECTION

SUMMARY

REPORT FOR CALVERT CLIFFS UNIT 1 ASME BOILER & PRESSURE VESSEL CODE SECTION XI, FORM NIS-2 Calvert Cliffs Nuclear Power Plant, Inc.

August 4, 2004

2004-1 Class I and 2 NIS-2's Completed

%N&"4Imb fu'ti

'I

Vi, 1199700129 97-1-027 1 MOV658 Two 1200200636 2003-1 -047a 1 CKVCVC-1 87 One 2003-1-047b 1 #CC5-1005 One 1200200640 2003-1 -M48a 1 CKVCVC-184 Two 2003-1 -048b 1 #CC7-1009 Two 1200200641 2003-1-049a 1 CKVCVC-435 One 2003-1-049b 1#CC5-1006 One 1200202505 2002-1-049b 1 HVCVC-172 Two 2002-1 -049c 1#CC7-1 002 TWO 1200202602 2002-1-033 1PUMPRC11B(s)

One 1200202689 2002-1 -050a 1 CKVCVC-1 71 Two 2002-1 -050b 1#CC7-1002 Two 1200202762 2002-1-051 1 CV1OF One 1200203109 2003-1-046a 1CKVSI-426 Two 2003-1 -046b 1 #DC2-1003 Two 1200203364 2003-1-056 1RV200 One 2003-1-056a 1#CC10-1007 One 1200203390 2004-1-027 1 PZVRXI1 One 1200203521 2004-1-010 1CV4070 Two 1200203958 2003-1-032-IPIJMPRC12A(s)-

One 1200203966 2003-1-008 1 RV201 One 2003-1 -008a 1#CC10-1008 One 1200204093 2003-1-057 1 ERV404 One 2003-1 -057a 1#CCI0-1004 One 1200204377 2003-1-058 1 ERV402 One 2003-1 -058a 1 #CCI0-1003 One 1200204580 2002-1-052 1RV200 One 2002-1-062 1 #CCI0-1007 One 1200204888 2002-1-060 1#CC-2,1" & under One 2003-1-022b 1#CC7-1001 Two 1200205233 2003-1-022c 1 HVCVC-166 Two 2003-1 -022a 1 CKVCVC-165 Two 2003-1-052c 1 HVCVC-178 Two 1200205235 2003-1 -052a 1CKVCVC-177 Two 2003-1 -052b 1 #CC7-1003 Two 1200205240 2003-1-077 1#CCI0-1003-H3 One 1200205247 2003-1-078 1#CC10-1004-H3 One 2003-1-023b 1#CCIO-1001 One 1200205332 2003-1-023a 1 MOV403 One 2003-1-024a 1 MOV405 One 1200205334 2003-1 -024c 1#CC10-1002-R12 One 2003-1-024b 1#CC10-1002 One MEIU Reference No. 200447-22-3496

2004-1 Class 1 and 2 NIS-2's Completed 1200301717 2003-1-018 1 PUMPRC11 B(s)

One 1200303202 2003-1-080 1ACC233X-SUP Two 1200303410 2003-1-072 1 CV648 One 1200303794 2003-1-075 1ACC233Z-SUP Two 1200304508 2003-1-081 1 HVSI-4163 Two 1200400341 2004-1-009a 1#HC7-1004 Two 2004-1-009b 1#HC7-1004-H2/R3 Two 1200401939 2004-1-017 1#GC9-1003-R6 Two SNUB POOL SNUB-0-004 *Snubber Pool 1, 2, & 3 MEWU Reference No. 2004-47-22-3496

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl Calvert Cliffs Nuclear Power Plant, Inc.

1. Owner:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Date:

514/2004 Sheet I of 2

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 97-1-027, MWO No. 1199700129 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section X) Class:

1650 Calvert Cliffs Parkway, Lusby, Md. 20657 Two (address)

4. Identification of Systern SystemNumber 052 SystemName:

Safety Injection 5.(a)Applicable ConstructionCode and Class:

ASME Draft Code for Pumps & Valves,1968 Edition, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Conponet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Velan Enginnering Co.

1-MOV-658 NIA Low Pressure Safety Injection system supply to Shut Down Cooling Heat Exchangers Isolation valve 197S Repalred/Repi aced No

7. Description of Work:

This plan was for the pluging of the leak off line and seal welding the plug on 1 MOV-658, Low Pressure Safety Injection system supply to Shut Down Cooling Heat Exchangers isolation valve.

8. Tests Conducted:

Hydrostatic:E PneumaticE Pressure:

NIA psi.

Nominal Operating Pressure:

Inservice: 0 Leakage: C]

Functional: El Test Temperature:

NIA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A

/

GCharles H. Ballard Signed:

Engineering Technician Date:

5/4/2004 d-wnf-d)e~e ignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the periodto

/-2 O

.andstate to the bestofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures descrbed in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

___dCommnissions:

IV8 '?eTA/ 4'r M

o

//7

___7

-Inspector's Signature National Board, State, and Endorsements Date:e.-,/

200 4

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY

. As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

6/1512004 Sheet 1 of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-047a, MWO No. 1200200636 (address)

3. Work Performed by Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Comuponet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Velan Engineering Co.

SN: 335 N/A

  1. 11 Regen. Heat Exch. to #IIA RCS Cold Leg Loop Check Valve 1975 Repaired/Repl aced Yes CheckValve Enertech Inc.

408934 SN: 11269 NIA Valve, Nozzle Check, 2 In., 1500 2002 Replacement lb., Large Groove connections, Enertech, Tp. KRV (Mark#

212M3N)

Yes

7. Description of Work:

This plan was for the work needed to replace 1-CKVCVC-1 87, #11 Regen. Heat Exch. to #1 1A RCS Cold Leg Loop Check Valve.

8. Tests Conducted:

Hydrostatic:[]

Pneumatic1l Pressure:

2355 psi.

Nominal Operating Pressure:

Inservice: O Leakage: 3 Functional: E Test Temperature:

74 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (l) size is 8-1/2 in. x I I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RevalrlReplacgement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: NIA Expiration Date:

N/A 7

A7</

/

Charles H. Ballard Signed:

rcs Engineering Technician Date:

6/15/2004 Owner or

eesanee, Title '

Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9a9-a

-3 to i -

O -°

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bDo0h-2-D A

. $/)#7O//Z F

AUZ, 'OI; t&r§ZS Pot 7EZ-

-IW Commissions:

AJiJi9 3,1,trOn7/.

1 4-J 7/

5 1 16 1217791o A40115

,.Insectoes Signature National Board, State, and Endorsements Date:

/ /&'

200 h,

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES As Required by the ProvisIons of the ASME Code,Section II, D islon 1 Pg. I of_ 2

1. Manufactured and certified by Eiertech, A Diy. of Curtiss-Wright Flow Control Corp., 2950 BIrch St., Brea, CA 92821 Iname and address of N Certiflcate Holder)
2. Manufactured for
  • Calvert Cliffs Nuclear Power Plant, PO Box 17323. Baltimore, MD 21297-1323 Iname and address ef Purchaser)
3. Location of Instaliation Calvert Cliffs nuclear Power PIant-1650 Calvert Cliffs Parkway, Lusby, MD 20657 (name and address)

KR raig MD20990 A____None_____

4. Model No., Series No., or Type KRV Drawing Rev.

A CRN None

6. ASME Code. Section ilt. Division 1:

1995 W9.

1 NQne (edition) laddenda date)

(claess (Code Cese no.)

6. Pump or vaive Nozzle Check Valve Nominal Inlet size 2

Outlet size 2

On.7 ItnNl

7. Material:

Body SA-479 Type 316 86oinel N/A DsA

.-479 Tye 16 Bolting N/A (a)

Cert.

Holder's Serial No.

11256 11257 11258 11259-11260 11261 11262 11263 11264 11265 11266 11267 11268 11269 11270 11271 11t272 11273 I.

.. W Nat'l Board No.

None None None None None None None None None None None None None None None None None None IC)

Body Serial No.

KNG-001 KNG-002 KNG-003 KNG-004 KNG-005 KNG-006 KNG-007 KNG-OO0 KNG-009 KNG-01 0 KNG-011 KNG-012 KNG-013 KNG-014 KNG-015

  • KNG-016 KNG-017 KNG-018 (d)

Bonnet Serial No.

None None None None None None None None None None None None None None None None None None (e1 Disk Serial No.

KNH-001 KNH-002 KNH-003 KNH-004 KNH-005 KNH-006 KNH-007 KNH-008 KNH-009 KNH-010 KNH-O11 KNH-012 KNH-013 KNH-014 KNH-015 KNH-016 KNH-017 KNH-01 B

  • Supplemental kormation in form of Usts. sketches. br drawings may be used provided (11 adze Is BI x 11, (2) hIformation hI kems I through 4 on this Date Report is Included on each sheet. 131 each Sheet is numbered and the number of sheets Is recorded at the top of this foT.

(12188)

This form (Eoo0371 may be obtalned from the Order Dept.. ASME. 22 Law Drive. Box 2300, Fairfield. NJ 07007.2300.

REPRINT M3

.M NPV-1 (Back-Pg. 2 of 2 )

c H11256 thru Certificate HOlder'S Serial No.

11273

8. Design conditions 2800 psi 250 or valve pressuro class 1500 (11 (pressurel Itemperaturel
9. Cold working pressure 3600 psiastIO1,F
10. Hydrostatic test 5400 psi. Disk differential N/A test pressure

_psi II. Remarks: Qly 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN Design Specification certified by JohnR.Sponsel, P.E. State MD Re9. no 17308 Design Report certified by IraJ,Silverman P.E. Stase Reg. no.

23241 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2826 ExpM -

10/11/05 Date -

Enelecsme Ech.Aoiv of Cit-WrigAhePbw CoolCofp e

(N Certificate Holder Signed (authorized represantaftve)

CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boler and Pressure Vessel Inspectors and the State or Province of Califomia snd employsd by HSB CT of Connecticut have inspected the pump, or valve, described In this Data Report on l

. t9Z

. and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, In accordance with the ASME Code.Section III, Division 1.

By signing this certificate; neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report; Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date /. £390Signed eiz P ESo missions e

(Auhorized Inspectori (Nat'l 3d. (nict. endotsements) and stae or prov. and no.1 (11 For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

611412004 Sheet 1 of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-047b, MWO No. 1200200636 (address)

3. WorkPerformedby:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class 1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, ox Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Piping System Bechtel 2"CC-5-1005 N/A

  1. 11A Charging Line Stop Valve 1975 Repaired/Repi aced No Pipe Nut AlIthread Rod DuBose National Energy Services Inc.

Mackson Inc.

Mackson Inc.

400298 Ht.#: 8324H 408227 Ht.#: S44018 410155 Ht.#: S20751 411064 Heat Code:

XX13 N/A Pipe, 2 In., Sch. 160, ASME SA-376, Tp. 316 NIA Nut, Heavy Hex, 7/8 In. X 9 TPI, ASME SA-194 Gr. 2H

-N/A Rod, Aluth read, 7/8 In. X 9 TPI, ASME SA-193 Gr. B7 N/A Flange, 2 In., 1500 lb., Large Tongue, Weld Neck, ASME SA-182, Tp. F 316 2000 Replacement 2002 Replacement 2003 Replacement 2003 Replacement No No No No Flange Energy & Process Corporation

7. Description of Work:

This plan was for the piping, fittings, hanger support work and fasteners needed to support the replacement of 1-CKVCVC-187, #11 Regen. Heat Exch. to #1 1A RCS Cold Leg Loop Check Valve.

8. Tests Conducted:

Hydrostatic:.

PneumaticC Pressure:

2355 psi.

Nominal Operating Pressure:

Inservice: E Leakage: W Functional: E Test Temperature:

74 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet2of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xi Pre-Service NDE Requirements.

A Section Xl System Leakage Test of the affected component was performed durina the system conditions listed in section 8. of this report.

A Section Xi Surface Examination of the affected component was performed to satisy Section Xi Pre-Service Requirements.

Code Case N-416-2 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Reopacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

G Engineering Technician Date:

6/14/2004 Own err or 6wrefiDesi-g e, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9-A2 -03 to S - XO °

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

OOci-JDz-I 4

- S 4in'/[l4 r-cv cT,;-,,d 5 PetYL -

-r-6 Commissions:

NA/ 'j&3 J.

M//7/< 8,'/

, nsnecto,'s Signature National Board, State, and Endorsements Date:

/6 200

I J

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner.

Calvert Cliffs Nuclear Power Plant, Inc.

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Date:

6/1412004 Sheet I of 2 Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-048a, MWO No. 1200200640 (address)

3. WorkPerfornedby:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

System Number 041 System Name:, Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves,1968 Edition, March 1970 Add; Class 1:

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, ot Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Velan Engineering Co.

SN: 1404 NIA

  1. 1I Regen. Heat Exchanger Inlet Check Valve (Containment Isolation) 1975 Repaired/Repi need Yes Yes Check Valve Enertech Inc.

408934 SN: 11266 N/A Valve, Nozzle Check, 2 In., 1500 2002 Replacement lb., Large Groove connections, Enertech, Tp. KRV (Mark#

212M3N)

7. Description of Work:

This plan was for the work and parts needed to replace 1-CKVCVC-184, #11 Regen. Heat Exchanger Inlet Check Valve.

8. Tests Conducted:

Hydrostatic:j]

PneumaticC kPressure:

2355 psi.

Nominal Operating Pressure:

Inservice: r Leakage: 6 Functional: a Test T icnperatwe.

Z74 Dcg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 1 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

-I 1

j I_0 Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakace Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached

-Certificate of Compliance We certify that the statements made in this. tOwnt tre correct and that this Repalr/Replacement conforms to the rules of the ASM IWde, Section X1.

Type Code Symbol Stamnp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/14/2004 Ownmer ori5AersTsizhee, it Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9 -a S -5O3 to 6 - rO 9Y

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DOAb)4,O A. Se-/ 1,6J4 F:ce,A,..

,U1)L2_ai< PL-&

Commissions: /dC 9 831,

//7/

4-"11 A Insnctors Signature National Board, State, and Endorsements Date:

t 1

200--

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, DIv1slon I Pg. 1of.2...

1. Manufactured and certified by Enertech, A Diy. of Curliss-Wright Flow Control Corp., 2950 Birch St.. Brea, CA 92821 (name d addresa of N Certificate Holderl
2. Manufacted for
  • Calvert Cliffs Nuclear Power Plant, PO Box 17323, Baltimore, MD 21297-1323 (name and address ef Purchaser)
3. Locationof installetion Calvert Cliffs nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (name and address)
4. Model No., Series No., or Type KRV Drawing MD20990 Rev.

A CRl None

6. ASME Codo. Section RI, Division 1:

1995 1q96 I

NQne leditionl leddends date)

(isasl (Code Case.o.I

6. Pump or valve Nozzle Check Valve Nominal Inlet size Outlet size 2

(in.)

oin.g

7. Material:

Body Bonnet ______________

DiskSA.-479 Type 318 Botn N/A la)

Cert.

Holder's Serial No.

11256 11257 11258 11259 11260 11261 11262 11263 11264 11265 11266 11267 11268 11269 11270 11271 11272 11273

..lb)

Nat'l Board No.

None None None None None None None None None None None None None None None None None None

, c)

Body Serial No.

KNG-001 KNG-002 KNG-003 KNG-004 KNG-005 KNG-006 KNG-007 KNG-008 KNG-009 KNG-010 KNG-011 KNG-012 KNG-013 KNG-014 KNG-O1 5

  • KNG-016 KNG-017 KNG-018 (d)

Bonnet Serial No.

None None None None None

KNH-001 KNH-002 KNH-003 KNH-004 KNH-005 KNH-006 KNH-007 KNH-008 KNH-009 KNH-010 KNH-01 1 KNH-01 2 KNH-013 KNH-014 KNHII-015 KNH-016 KNH-017 KNH4018

  • Supptementai Information in form of Ustsa sketches, br drawings may be used provided (II size Is 8 1 x 11, 12! Information In Items 1 through 4 on this Data Report is Included on each shoet, 13) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

112/88)

ThIs form IE000371 may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007 2300.

REPRINT W93

  • I -t-1

..AMNPV-1 IBack-Pg.2o:f 2 )

11256 thru Certificate Holder's Serial No.

11273

8. Design conditions 2800 psi 250 or valve presaur dess 1500 (pressure) ltemperature)
9. Cold working pressure 3600 psi at 1 o0F
10. Hydrostatic test 540 psi. Disk differential test pressure N/A psi I1. Remarks: Oty. 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN Design Specification certified by John R. Sponsel, I P.i State MD Fleg. no.

17308 Design Report certified by-Ira J, Silverman PE State Ceg no.

23241 CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section Ill, Division 1.

N Certificate of Authoritation No.

N-2826 10/11/05 Data me//6/A'3 Nmame Frb ADh io !CwFtCo Signed

?

d Z

IN Certificate Holder)

(authorized representativei CERTIFICATE OF INSPECTION 1, the undersigned. holding a valid commission Issued by the National Board of Bolrer and Pressure Vessel Inspectors and the State or Province of Caitomia and employ d by HSB CT of Connedicut have inspected the pump, or valve. described in this Data Report on l

O

5.

and state that to the best of my knowledge and bellel, the Certificate Holder has corn structed this pump. or valve, In acaordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described In this Data Report: Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Data Signed AE..

ComComm issions

'>'a

',0C4,%

2 '

(Authorized Inspector)

(Net'l. Wd. ncd.

endorsements) and stats or prev. and no.)

(1) For manually oparatrd valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Date:

611412004 Sheet I of 2

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-048b, MWO No. 1200200640 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System System Number 041 SystemName:

ChemIcal Volume Control 5.(a)ApplicableConstructionCodeandClass:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Componet Name of Manufacturer Manufacturers Serial Number National Board No.

Other Identification ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Piping System Bechtel 2" CC-7-1009 N/A Charging Pumps discharge piping 1975 to Containment Penatration #28.

Repaired/Repi aced No Pipe Nut Ailthread Rod DuBose National Energy Services Inc.

Mackson Inc.

Mackson Inc.

400298 Ht.#: 8324H 408227 Ht.#: S44018 410155 Ht.#: S20751 409374 Ht. Code:

BHZ N/A Pipe, 2 In, Sch. 160, ASME SA-376, Tp. 316 NIA Nut, Heavy Hex, 7/8 In. X 9 TPI, ASME SA-1 94 Gr. 2H N/A Rod, Allthread, 7/8 In. X 9 TPI, ASME SA-193 Gr. B7 N/A Flange, 2 In., 1500 lb., Large Tongue, Socketweld, ASME SA-182, Gr. F316 2000 Replacement 2002 Replacement 2003 Replacement 2003 Replacement No No No No Flange DuBose National Energy Services Inc.

7. Description of Work:

This plan was for the piping, fittings, hanger support work and fasteners needed to support the replacement of 1-CKVCVC-1 84, #11 Regen. Heat Exchanger Inlet Check Valve.

8. Tests Conducted:

Hydrostatic:[]

Pneumaticf]

Pressure:

2355 psi.

Nominal Operating Pressure:

Inservice: El Leakage: i Functional: al Test Temperature:

74 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 1 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI Svstem Leakaae Test of the affected component was oerformed durina the system conditions listed in section 8. of this report.

Code Case N-416-2 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to sahsfv Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached We certify that the statements made m s repon are correcxaa this conforms to the rules of the ASME Code, Section Xl.

Repair/Reolacement Type Code Symbol Stamp:

NIA Certificate of Authorization No.: N/A Expiration Date: N/A Signed:

Charles H. Ballard Engineering Technician Date:

6/14/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod 9-S-03 to 8-t

°v

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Da'J41D /1, SPI-PI/Df AL q1Z re iAJ/

AFEZ Is" Commissions: A £ 9

  • 3 I.,4-/) 1/7/

A.ta

/

D a t e A

0 0 '

Date:

G -&

200 C~-

A'6Natioaiioard State, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Plant+.

Calvert Cllffs Nuclear Power Plant Date:

611612004 Sheet I of 2 Unit:

One z.,...

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant D4 (name)

R&R No. 2003-1-049a, MWO No. 1200200641 (P.O. no., job no., etc.)

apt.

Type Code Symbol Stamp: N/A ap. Authorization No.: N/A Exp Date: N/A Section XI Class:

One 1650 Calvert Cllffs Parkway, Lusby, MD 20657 (address)

4. Identification of Systemn System Number 041 System Name:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class I I

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Cormponet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Velan Engineering Co.

SN: 4248 NIA

  1. 11 Regen. Heat Exch. to U11A RCS Cold Leg Loop CV By Pass Check Valve 1975 Repalred/Rept aced Yes Check Valve Enertech Inc.

408934 SN: 11270 N/A Valve, Nozzle Check, 2 In., 1500 2002 Replacement lb., Large Groove connections, Enertech, Tp. KRV (Mark #

212M3N)

Yes

7. Description of Work:

This plan was for the work needed to replace 1-CKVCVC-435, #11 Regen. Heat Exch. to #1 1A RCS Cold Leg Loop CV By Pass Check Valve.

8. Tests Conducted:

Hydrostatic:5 PncumaticO Pressure:

2355 psi.

Nominal Operating Pressure:

Inservice: E Leakage:R Functional:fl Test Temperature:

74 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet2of 2 It7.

FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Revalr[Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A

~elr 7Charles H. Ballard Signed:

Eni ng Technician Date:

6/16/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod

/-1/103 to

(~//

0y and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

b644 1 A -S43HfmH

/f,,.

G

'J-t Commissions: AJ 83 913/,

Yad //)1, 4O'WE r

JS r /Nt7i7o Br SA a

//

ESS Insnector's Sian~ature National Board, State, and Endorsements Date:

i - / 7


2-0-0D--

FORM NPV-1 CERTIFICATk HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES As Required by the Provisions of the ASME Code, Section 111, Division I 2

Pg. 1 oi.2..

1. Manufactured and certified by Enertech, A Div. of Curtiss-Wright Flow Control Corp., 2950 Birch St., Brea, CA 92821 Inamer and eddrest of N Certficate Holder)
2. Manufactured for Calvert Cliffs Nuclear Power Plant, PO Box 17323, Baltimore, MD 21297-1323 Inarme and address of Prchaser)
3. Locatlon of installation Calvert Cliffs nuclear Power Plant; 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Iname and address)
4. Model No., Series No., or Type KRV Drawing MD20990 Rev.

A CRN None

6. ASME Cod, Sectlon* Ilt, Division 1:

1995 I9 NoneWm ledition)

(addenda date)

(class)

(Code Case no.)

6. Pump or vave Nozzle Check Valve Nominal Inlet slzo 2

Outlet size 2

on.)

(In.

N

7. Material:

Body SA-479 Type 316 Bdninet N/A Disk SX-479 TYPe 316 BolN/A (a)

  • Cart.

Holderes Serial No.

11256 11257 11258 11259 11260 11261 11262 11263 11264 11265 11266 11267 11268 11269 11270 11271 11272 11273

.. b)

Nat'I Board No.

None None None None

.None None None None None None None None None None None None None None (c)

Body Serial No.

KNG-001 KNG-002 KNG-003 KNG-004 KNG-005 KNG406 KNG-007 KNG-008 KNG-009 KNG-O1 0 KNG-01 1 KNG-012

  • KNG-013 KNG-014 KNG-015
  • KNG-016 KNG-017 KNG-018 (dl Bonnet Serial No.

. None None None None None None None None None None None None None (a)

DlsIk Serial No.

KNH-001 KNH-002 KNH-003 KNH-004 KNH-005 KNH 006 KNH-007 KNH-008 KNH-009 KNH-010 KNH-011 KNH-012 KNH-013 KNH-014 KNH-015 KNH-01 6 KNH-017 KNH-018

  • Supplamentdl Information in form of lists, sketches. br drawings may be used provided (1) size Is 81$ x 11, (2) information In iems 1 through 4 on this Data Report Is Included on each sheet. (3) each sheet is numbered end the number of sheets Is recorded at the top of this forn.

(12)88)

This form iE000371 may be obtained from the Order Dept.. ASME, 22 Law Drive, 3ox 2300, Fairfield, NJ 07007-2300.

htPINTOW4

r.

IM NPV-1 (Back -Pg. 2 of 2.)

o 'S 11256th7 ICertificate Hoideres Serial No.

11273 S. Design conditions 2800 250 F or valve pressure dass 1600 11)

(pressure)

Itemperature)

9. Cold working pressure 3600 psi at 1I 60F
10. Hydrostatic test 5400 psi. Disk differential test pressure N/A IPsI I1. Remarks: Oty. 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN DesignSpecificationcertifiedby John R. Sponsel, 11 P.E. Ste MD Rg. no.

17308 Design Report certified by Ir J. Silverman CA 23241 Saeng o

CERTIFICATE OF COMPUANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authoiation No N-2826 110/11/05 Dato Name E

Ane C)'k Deiv.

FowC Cop Signed.

(N Cenimicate Holderl (authorized representaftv)

CERTIFICATE OF INSPECTION 1I the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the Stat. or Province of Californi a and emp ed byBCT of Connecticut have Inspected the pump, or valve, described in this Data Report on

  • 1
  • OT5

, and state that to the best of my knowledge and belief, the Certificate Hold'er has con-structed this pump, or valve, In accordance with the ASME Cods,Section III, DivIsIon 1.

By signing this certiflcate; neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date -bL0L350SIgned A 7

ommissions eA4 pJ864wA (Authorized Inspector (Nael. 8d. lincL endorsements) and stat or prov. and nol

1) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required by the Provislons of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

611612004 Sheet I of g 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (addess)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name) unit.

One R No. 2003-1-049b, MWO No. 1200200641 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&F (address)

3. WorkPerformedby:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no.,job no., e*c.)

Type Code Symbol Stamp: NA Authorization No.: N/A Exp Date: N 1650 Calvert Cliffs Parkway, Lusby, MD 20657 SectionXI Class:

One (addess)

4. Identification of System:

SystemNumber 041 SystemName:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

A.SME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for RepairslReplacement 1998 Edition Identificatidon of Components Repaired or Replaced ind Replacement Components:

ASME.

Rcpaired, Code Year Replaced, o: Stamped Built Replacemer (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National BoardNo.

Other Identification Piping System Bechtel 2"CC-5-1006 Pipe DuBose National Energy Services Inc.

Nut Mackson Inc.

Allthread Rod Macksou Inc.

'Flange Energy & Process Corporation Reducing Tee Energy & Process Corporation Plate Energy Steel &

Supply Co.

Pipe Tloga Pipe Supply Co. Inc.

400298 E1.0s 324E 408227 Ht: 54401S 410155 EtA. S20751 411064 Beat Code:

XX13 411064 Ht: 70802 402572 Ht.:

832N34270 402564 Et.#: L42618 N/A

  1. 11 Regen. Heat Exch. to II1A RCS Cold Leg Loop CV By Pass piping N/A Pipe, 2 In., Sch. 160, ASME.SA-376, Tp. 316 N/A Nut, Heavy Rex, 7/8 In. X 9 TPI, ASMESA-194 Gr.2H N/A Rod, Ailthread, 7/8 In. X 9 TPI, ASME SA-193 Gr. B7 N/A Flang, 2 In, 1500 lb., Large Tongue, Weld Neck, ASME SA-182, Tp. F 316 NIA Tee, Reducing, 2 In. X 314 In.,

Sc.I60, butt weld, ASME SA-403, Gr. WP316 N/A Plate, Steel 1/4 In. X 48 In. X 96 In., ASME SA-36 NIA Pipe, 3/4 In. Sch. 160, ASME SA-376, Tp. 316 1975 Repalred/Rept aced No 2000 Replacement 2002 2003 Replacement Replacement 2003 Replacement 2003 Replacement 2001 Replacement 2001 Replacement

  • No No No no No No No
7. Description of Work:

This plan was for the piping, fittings, hanger support work and fasteners needed to support the replacement of 1-CKVCVC-435, #I11 Regen. Heat Exch. to #11A RCS Cold Leg Loop CV By Pass Check Valve.

NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8-1/2 in x l lin., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheetgpf.-

fib FORM NIS-2 (Back)

8. Tests Conducted:

HYdostatic:O PneumaticO Pressure:

2355 psi.

Nominal Operating Pressure:

is ervice: 0 Leakage: E Functional: a Test Temperature:

74 Deg. F

9. Remarks:

A Section Xi VT-1 Visual Examination of the replacement threaded fasteners was oerformed to satisfv Section Xi Pre-Service NDE Requirements.

A Section XI System Leakaqe Test of the affected component was Performed durina the system conditions listed In section 8. of this report.

A Section Xi VT-3 Visual Examination of the affected component support was performed prior to the system belna returned to service.

A Section Xi Surface Examination of the affected component was oerformed to satisv Section Xl Pre-Service Requirements.

Code Case N-416-2 was Invoked to satisfy Section XI required oressure tests. Addtlonal Section IlIl Examinations were performed fas applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASM Code,Section XI.

Renalr/Repfacernent Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Signed:

° Charles H. Ballard Engineering Technician Date:

6/16/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period // -/3 -03 to 6 -// " 5

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

b00J4t4O4. Sp4k1e Ait,I,2.

Ar AdVUJ?_Zt I s 69 6'-~

1/-0Z/

Inspectoes sigatr Date:

6;- / ^7 200 VIsr Commissions:

AOld 963 / / Alm)I

//7/J 4A //

N a i a B ao r

2

,7 aX an E n d orse m ent National Board, State, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

0113012003 (namne) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (add)ss)

2. Plan Calvert Cliffs Nuclear Power Plant Unit-One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-049b, MWO No. 1200202505 (add=s)

(P.O. no, job no, ect.)

3. WorkPerformedby:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: Y (namc)

Authorization No.: N/A Exp Date: M 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Sectio XI Class:

Two (address)

4. IdentificationofSystem:

SystemNumber 041 SystemName:

Chemical Volume Control 5.(a) Applicable ConstructionCode and Class:

ASME Draft Code for Pumps & Valves, 1968 EditIon, March 1970 Add; Class Two (b) Applicable SectXI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Otiher Year Replaced,oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemm (Yes or No)

Valve Velan Engineering NIA

  1. 12 Charging Pump Discharge 1975 Repalred/Repl Yes Co.

Isolation Valve sced Gate Valve Velan Engineering 90585-GX SN:

NIA Valve, Gate, 2 In. 1690 lb.; ASME 1994 Replacement Yes Co.

951075-1 SA-1S2 Tp. F316

7. Description of Work:

This plan was for the replacement of 1-HVCVC-172, #12 Charging Pump Discharge Isolation Valve.

8. Tests Conducted:

HYdrostatic:Q PCumalicf Nominal Operating Pressure:

bIservice: [1 Leakage:R FunctionaL 5 Pressure:

2300 psi.

Test Temperature:

118 Deg. F NOTE: Supplemental sheets in fonn of lists, sketches, or drawings maybe used, provided (I) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form

k7U Sheet2of 2 FORM NIS-2 (Back)

9. Remarks:

Code Case N-416-1 was invoked to satisfy Section Xi required Pressure tests. Addtlonal Section il Examinations were performed (as aDDlicable) to satisfv Code Case N-41-1 and Req.Gulde 1.147.

Applicable Manufacturer's Data Reports to be Atached Certificate of Compliance We certi dat the statements made in this report are corTect and that this Repair/Replacement confotmso the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate ofAuthorization No.: N/A Expiration Date: N/A 00

<Charles H. Ballard Signed:

Engineerng Tchnician Date:

01/30/2003 Owner or Ownees Designce. rite I

Certificate of Inservice Inspection I, the undersigned, holding a valid cormnission issued by the National Board of Boiler and Pressure Vessel inspectors and the Statepf Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period l L.

4 3/< to ;ZL2

/

A9 3

and state to the best of my knowledge and belief, the Owner has performed exaninations and taken correctve measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any wanrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthennore, neither the Inspector nor his employer shall be liable in any mamer for any personal injury or property damage of a loss of any kind arising fkom or connected with this inspection

/f Commissions: PA z

  • iso6 4A. I S,

d!

5**37 lnspectoeis Sigature National Board, State. ia Endorsements Date: 2..

t 20013

.V i

r I

-I

    1. ^

il-;

DATA PACKAGE NO.

_95075 P.7 FORM WPV.-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUmPS OR VALVES

  • An Required by the Provisions of the ASHE Code, Section 1U3, Division I Pa. I of 2
1. manufactured and cert
2. manufactured fos_

t iled by VEIM ruNC. 2125 IWARD AVE.

MTh.

QXNADA m sad addess of N Cafiicakt Holder)

BALTIMORE GAS & ELECTRIC P.O. BOX 1472 BALTYMORM. Mfl 2ii20

_ _ _ _ c,

  • ^ & v a
3. Location of installIon CA eVERT CIIFFS NUCLEAR PLANT NORTH OF LUSBY.

MD.

206S7 anmc nd adds)

4.

Modal No., Series No., or Types -GATE Drawin P-76800-a22 Rev FL CR..

ciw

_A

5. ASS Code, Section U!, Dirision Is a 1989 NOE-

/A (edito (addcnda date)

(class)

(Codcase Cm o.)

6. Pump or valve NAM Nominal inlet size 2

Outlet sire 2v M.)

W

7. materials Body SA-182.F316 Boet SA-l82.F316 Disk SA-351.CFEM Bolting SA-54.,6o3 SA-194.6 (a)

Cert.

Holder' a Serial No.

u51075-1 w

§ 9 75-.,

w=

==-

(b)

Nat' 1 Board NO.

N/A (C)

Body Serial No.

- I/Cl E-ER W

a-Wsg (d)

Bonnet Serial No.

H/C: ADU 4'

ass e~is (e)

Disk Serial No.

- X/C ; 03R_

91.

S tflfls.

suppw=a lal rmation In frbm of =ss, wces, or drwaings may be Used provided (1) sIe I s 12 x I 1, (2)

Inhformtln In Item: I trough4 on this Da Rep=o is Incjuded o each,ee; (3) each shd Is sumbered and the number of ahee4 is recorded at t Itop of tld5 fbrm.

(12133)

ThM frm (E0037) may be obtained from te Order Dept, ASM, 22 L&W DBZVE< BOX 2300 Fairfield, M 07007-2300.

1.

0

t FORQ MV-1 (Back - Pg. 2 of 2

.7 Certificate Rolder's SBezrial No.

951075

8. Design conditions _405S psi

.100 o

ps or valve pressure class 1690 (1)

(PraUM) oacmnro))

9. Cold working pressure 405 psi at 100?*
10. Bydrostatis teat _

6350 psi. Disk differential teat pressure 46S0 pSi

11. Remarks s MATBRIALS ?MBBT ASMR SMCI N Il MDITIO: 1989 ADDENDA2 NXON CZRTZPICkU OP D3SS62 Design Specification certified by J.M. FARRBTJ P.Z. State OUR Reg. no.

30032 Design report certified by S. ____TSKY P.R. State _QgL_ Reg. no. 22125 CRRTI1ZCAT3 OP COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASMB Code, Section IIU, Division 1.

N Certificate of Authorization No..

N-2797-1 REpires MAY 2.95 Date N

2 Zlame VULAN INC.

Signed c v4..

=

(- -- OCmaCfa Holdv(*

zcp=roseudh)

CZRTIPICATS OW INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of OUEBBC and employed by PROVIWCE of OUEBRC!

have inspected the pump, or valve, described in this Data Report on

-- o-Z.F

, and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warrenty, expressed or implied, concerning the component described in this Data Report.

Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with thia inspection.

Date Si-°z-.

2-ssgn s___Cosml 9

ons

'ozc0t (Ki.

Rd. ancL wdorment) ad s'ats og pQCm.

ad o)

(1) For manually operated valves only.

RAYMOND LA'C.;CN D

RPtIE OU aArMENTsLu C'J£3,C

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi Caivert Cliffs Nuclear Power Plant, Inc.

1. Owner

(_M) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (addrss)

.Caivert Cliffs Nuclear Power Plant Date:

0113012003 Sheet 1 of tL unit..

One R&R No. 2002-1-049c, MWO No. 1200202505

2. Plant (name) 1660 Calvert Cliffs Parkway; Lusby, MD 20657 (address)
3. WorkPerformedby:

Cavert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

(P.O. nojob no, etc.)

Type Code Symbol Starop: NIA Authorization No.: ;Q, Exp Date: NIA Section Xl Class:

Two

4. Identification of System:

SystemNumber 041 SystemName:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Summer 1971 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

- -Repaired, Code Year Replaced, ot Stamped Built Replacemer (Yes or No)

Name of Componet Name of Manufacturer Manufacturers Serial Number National Board No.

Other Identification Piping System Bechtel NIA Pipe Reducer Insert Consolidated Power Supply Ladish Co.

Tee DcBose National Energy Services Inc.

Pipe Strap Anvil Internatonal Inc. (Grinnell Pipe Supports)

Elbow Consolidated Power Supply 20439 HeatN 447/

XBJ FP8588 Heat Code:

D6MC Hl 54906-GX Heat Code: RV 34757 408879 Heat Code:

MA N/A f12 ChargIng Pump Discharge Piping NIA PIpe, 2 In. Sch. 160, ASME SA-376Tp.316 N/A Reducer, Insert. 2 In. X 3/4 In, ASME SA-182, Gr. F316, Socketweld, 6000 lb.

N/A Tee, 2 In., 6000 lb., ASME SA-112, Tp. F316, Socket Weld N/A Strap, Pipe Guide, 2 In, Part# 2 of PG-44 en Drwg.# FSK-MP-0S71SH 005 &6 N/A Elbow, Pipe, 2 In., 45 Deg, 6000 lb, Socketweld, ASME SA-12, Gr. F316 1975

-RepalredtRepl aced 1998 Replacement 1973 Replacement 1992 Replacement 1999 Replacement 2002 Replacement No No No No No No

7. Description of Workc This plan was for the use of the parts listed herein to support the replacement of 1-HVCVC-172, #12 Charging Pump Discharge Isolation Valve. This plan also covers any work on supports/hangers needed to support this work.
8. Tests Conducted.

Hydrostatic:o Pneumatico Nominal Operating Pressure:

Inservice: Ol Leakage. O Functional C3 Test Temperature:

118 Deg. F Pressure:

2300 psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-l/2 in. x I I in, (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet:kof a FORM NIS-2 (Back)

9. Remarks:

Code Case N-416-1 was Invoked to satisfy Section XI required Pressure tests. Addtional Section III Examinations were oerformed (as apalicable) to satisfy Code Case N-416-1 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance W certi that the statements made in this report are correct and that tis ReoallRenlacemnt conoms to the rules of the ASME Code,Section XI.

Type Code Symibol Stamp:

N/A Certificate ofAuthorization No.: NIA Expiration Date: N/A Charles H. Ballard Signed:

Engieering Technician Date 01/30/2003 Owner or Owne sDesl ne;Titfe Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectoms and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components descnbedin ffiis Owner's Report ding the period /64 /I.2. -to _2j//o3

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken correctve rrteasureu described in this Owner's Report in accordance with the requirernents of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any wamnt, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inxury or property damage of a loss of any kind arising forn or connected with this inspection.

/7h sx

)(3 Comnmissions: A20? ZoS-19 4 I tJ'4 fliA 37Z Lnspetoes Signature National Board, State, and Endorsements Date:

200

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

. O Calvert Cliffs Nuclear Power Plant, Inc.

Date 0810412003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant Calvert Cliffs Nuclear Power Plant Unit One (nae) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-033, MWO No. 1200202602 (address)

(P.O. no.job no., etc.)

3. WorkPerformedby.

Calvert Cliffs Nuclear Power Plant Dept Type Code Symbol Stamp: N/A (name)

Authorization No.: NIA Exp Date: N 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

SystemNumber 064 SystemName:

ReactorCoolantSystem 5.(a) Applicable Constuction Code and Class:

ASME B&PV Code Sect. III, 1983 Edition, Summer 1983 Add; 5is `s-

-i (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

.6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, o0 Stamped Componet Manufacture Serial Number Board No.

Identification Built Rcplacemen (Yes or No)

RCP Seal Sulzer Bingham SN: 1C870 NB 1290

  1. 11B Reactor Coolant Pump 1988 RepalredtRepl Yes Inc.

Mechanical Seal.

aced Seal BCE CCNPP Shops 1199901394 SN:

NIA Seal, Cartridge Assembly (RCP) 1999 Replacement Yes 1864 875 i Complete Sulzer Bingham per FCR £740074

7. Description of Work This plan was for the replacement of the mechanical seal on #11 B Reactor Coolant Pump
8. Tests Conducted.

Hydrostatic:[

Paeumaticf Nominal Operating Pressure:

Inseice: C]

Leakage: 2 Functional:;

Pressure:

2250 psi.

Test Temperature:

A28 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is S-112 in x 1I1 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is mbhered and the nunber of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakaae Test of the affected component was performed durina the system conditions listed in section 8. of this report Applicable Manufacturers Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct aCd that this Revafr/Renlacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A CertificateofAuthorizationNo.:

N/A ExpirationDate:

N/A Charles H. Ballard Signed:

Engineering Technician Date:

08/04/2003 Ower fwe

nscsg, Tidle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by AB§ Consulting of Houston, Tx. ave inspected the components descrnbed in this Owner's Report during the period _ -7 3

to t

/ xI okw

. andstatetothebestofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Fbrthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any Idnd arising from or connected with this inspection.

7 (z4 q

Commissions:A/atf/ o2/ 8 1/3 AB2WDi A

, inspectoes Sigature National Board, State, and Endorsements Date:

if / St 200 3

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

1210312003 Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657

2. Plant:

(address)

Calvert Cliffs Nuclear Power Plant (name)

Unit One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Di (name)

R&R No. 2002-1-050a, MWO No. 1200202689 (P.O. no., job no., etc.)

Ipt.

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

System Number 041 SystemName:

Chemical Volume Control

5. (a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves,1968 Edition, March 1970 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Componet Nane of Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Velan Engineering Co.

Check Valve Velan Engineering Co.

1-CKVCVC-171 90585-GX SN:

951037-1 N/A

  1. 12 Charging Pump Discharge Check Valve N/A Valve, Check, 2 In, 2680 Ib.,Socketweld, SA-182, Tp F316, BGE Dwg 12968-0138 1975 Repaired/Rep!

aced 1994 Replacement Yes Yes

7. Description of Work:

This plan was for the replacement of 1-CKVCVC-171, #12 Charging Pump Discharge Check Valve.

8. Tests Conducted:

Hydrostatic:[

PneumaticO Pressure:

2320 psi.

Nominal Operating Pressure:

Inservice: E Leakage: i Functional: E Test Temperature:

112 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 1 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Code Case N-416-1 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepafrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

c Engineering Technician Date:

1V03/2003 Owner or Owners ignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period to

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: It,9P3/0`31 A

I.9 /117/

Insoector's Signature National Board, State, and Endorsements Date: 4',

q200

-3

DATA PACrAGH NO.-

951037 P.6 rt 5'DATA REPO LAR P OVAES C

-9 Pg. I of, 2

1. Kanufactured and certified by YVEhAN INC. 2125 WARD AV_.

MTL. CANADA (name and address of F Ceruificate Holder)

2. Manufactured for BALTIMORE GAS & ELECTRIC

'P.O. BOX 1472 BALTIMORE, MD.

21203 (name and address of purchiser)

3. Location of installion CALVERT CLIFFS NUCLEAR PLANT NORTH OF LUSBY. MD. 20657 (rame and address)
4. Model No., Series No., or TQpes PS.CECK Drawing P1-76800-K28 Rev D

CRN N/A

5. ASME Code,Section III, Division It 198S NONE 1

NTA (editlon)

(addenda date)

(CUass)

(Code Case no.)

6. Pump or valve VALVE Koinal inlet size 20 Outlet size 20
7. Materials Body SA-182.F316 Bonnet SA-182,F316 Disk COLMONOY 4 Bolting N/&

(a)

Cert.

Holder ' s Serial No.

951037-1 951037-2

_ 951037-3 nfl--a--a----_

tb)

Nat' 1 Board No.

N/A (C)

Body Serial No.

H /C : CH U

U I9 ff td)

Bonnet Serial NO..

N...

H/Ce 1AR.A I,

  • (e)

Disk Serial No.

H/C: 2072 a

a

.3?

Supplemental Information in fbrn of Usts, iketches; or drawings may be used provided (1) ize is S 1/2 x I1, C2) Infornation In Itemns I through 4 on this Data Repoet Is Included on tact sheet, (3) each shee Is numbered and the number of sheets Is recorded at the top of Ihis form.

(12/88)

MIs form (500037) may bc obtaine from the Order Dept., ASME, 22 LAW DRI

<E<

BOX 2300 Fairfield, NJ 07007-2300.

PORQ PV-1 (Back - Pg. 2 of 2

P.7 S. Dexign conditions 6430 psi 100 OF or valve pressure class 2680 (1)

(preaxr)

ACmperd)

9. Cold working pressure 6430 psi at 1007Y
10. Hydrostatic test 10050 psi. Disk differential tes~t pressure 7375 psi
11. Remarkas MATERIALS MEET ASMa SECTION II EDITIONS 1989 AMDDENDA:

NONE CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2797-1

__xPirs

-MAY 2_98 Date MAY 2 61995 Name VELAN INC Signed __

(N Certificate. Holder)

A (autbov se3aZrve)

'1

CERTIFICATE OF INSPECTIOR I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of OUBBMC and employed by PROVINCE of OUEBEC have inspected the pump, or valve, described in this Data Report on 4-Y,- 4&

, and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warrenty, expressed or

implied, concerning the component described in this Data Report.

Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 925-signOS'2'

- Commissions _

rhoried Inspo0)

(Natel

d. Od.

endorsmmnt) and stats or prov. and no.)

(1) For manually operated valves only.

RAYMOND LAUZON Q

PMGI3 DU ATIMENTMTDOUA.o

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

11/06/2003 Sheet i of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657.

2. Plant:

(address)

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-050b, MWO No. 1200202689 (address)

3. WorkPerformedby:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Summer 1971 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 EditIon

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Comnponet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Piping System Bechtel 2" CC-7-1002 Pipe Tee Consolidated Power Supply DuBose National Energy Services Inc.

20439 Heat# 447 54906-GX Heat Code: BV N/A

  1. 12 Charging Pump Discharge Piping N/A Pipe, 2 In., Sch. 160, ASME SA-376, Tp. 316 N/A Tee, 2 In., 6000 lb, ASME SA-182, Tp. F316, Socket Weld 1975 Repaired/Repl aced 1998 Replacement 1992 Replacement No No No Insert Reducer Ladish Co.

F-8588 Heat Code:

D6MC H1 N/A Reducer, Insert, 2 In. X 3/4 In.,

6000 lb., Socketweld, ASME SA-182, Gr. F316 1973 Replacement No

7. Description of Work.

This plan was for the use of the parts listed herein to support the replacement of 1-CKVCVC-171, #12 Charging Pump Discharge Check Valve. This plan also covered work on supports/hangers needed to support this work.

8. Tests Conducted:

HydrostaticO PneumaticCj Pressure:

2320 psi.

Nominal Operating Pressure:

Inservice: 0 Leakage: i Functional: C]

Test Temperature:

112 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I 1 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Code Case N-416-1 was invoked to satisfy Section Xl required pressure tests. Addflonal Section III Examinations were Performed (as applicable) to satisfy Code Case N-416-1 and-Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section X.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

NIA Charles H. Ballard Signed:

Engineering Technician Date:

11/06/2003 Owner or Oirne~s Vesinei, Title`

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period_

to and state to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions:

?Ad q3

/,4O Z Alq1L/L?

_y p4

//

AlInspector's Signature Kate:

Im 3

200 -3 National Board, State, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owncr Calvert Cliffs Nuclear Power Plant, Inc.

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Date:

101312003 Sheet of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant DE (name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 R&R No. 2002-1-051, MWO No. 1200202762 (P.O. no., job no., etc.)

ept.

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section Xl Class:

I One (address)

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a)ApplicableConstructionCodeandClass:

ASMEB31.1.0 1967Edition,CCasesN-2,N110 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replaceint Components:

Name of Comnponet Name of Manufacturer Manufacturers Serial Number National Board No.

Other Identification ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Valve ITT Hammel Dahl Bonnet Flowserve Corporation 69-4126-002 400322 SN; D909A-1-1 10486-GX Heat Code: HTK 56479-GX SN:

R1613-1 Pipe Cap Dulose National Energy Services Inc.

NIA 11 lBPressurizerSprayCuitrol 197S Repalred/Repi Valve ed NtA Bont!i, Bellows, 3 In. 1500 lb.

2000.

Replacement ITT Hammel-Dahl Angle Valve, Drwg. #12121-0006, Item 02 NMA Cap, Pipe, 12 InI, 300Q lb. SW, 1996 Replacement ASME SA-482, Tp. 316 N/A Plugtor3 In. 1500 lb.ITT 1991 Replacement IHanid-Dabl Angle Valve, Drwg.

N1212140006, Item 16 No No No No Plug Neles Jamesbory

7. Description of Work:

This plan was for the rebuilding and replacement of the Bonnet and Plug on 1-CV-100F, which is #11B Pressurizer Spray Control Valve.

8. Tests Conducted:

Hydrostatic:Q Pncunaticl Pressure:

2250 psi.

Nominal Opaating Pressure:

Inservicc: 0 Lkahgc: 0 Functional: 0 Test Temperature:

532 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:.

A Section Xi Svstem Leakace Test of the affected component was Derformed durino the system conditions listed in section 8. of this report.

A Section Xl Surface Examination of the affected component was Derformed to satisy Section Xi Pre-Service Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Revalr/Renlacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: __

Engineering Technician Date:

10/3/2003 Owner or Ownces Designee, Title Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 6,:

to

//-/s-dL,.

and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthernore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

1 Commissions:

A/A, 7 11 3 421 //6W 44/A T nspectoe's Signature National Board, State, and Endorsemenpq, Date

'AC AK 200 -

S0

[ O ___ _

is.

FORM NIS-2 OWNER'S FEPORT FOR REPAIR / FKEPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6115/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-046a, MWO No. 1200203109 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

Two (address)

4. Identification of System:

System Number 052 System Name:

Safep nection 5.(a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves,1968 Editlon, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Valve Velan Enginnering 1-CKVSI426 N/A

  1. 13 High Pressure Safety 1975 Repalred/Repl No Co.

Injection Pump Mini Flow Check aced Valve CheckValve Enertech Inc.

411160 SN: 11319 N/A Valve, Nozzle Check, 2 In, 1500 2004 Replacement Yes lb, Enertech KRV, Body SA-479, Tp. 316, Disc SA-564, Tp.

6301H1075

7. Description of Work:

This plan was for the work needed to replace 1-CKVSI-426, #13 High Pressure Safety Injection Pump Mini Flow Check Valve.

8. Tests Conducted:

Hydrostatic:Fj Pneumatic:

Nominal Operating Pressure:

Inservice: f Leakage: j Functional: E Pressure:

1310 psi.

Test Temperature:

82 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 1 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

as

  • v Sheet 2 of 2 FORM NIS-2 (Back)
9. Remarks:

A Section Xl System Leakaae Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Revalr/Reolacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A K

A Charles H. Ballard Signed:

gineering Technician Date:

6/15/2004 Owner or Owne' Designee, Ttle I

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period _aA3 Ok to

'- 9S -9 A and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bco4J1D A, SW U1M fo& fe-ionjfJ sejoeads Pt.

ZYKE-fAi Commissions:

N6 98 3/,O1

//7X, 4A /

u N ai77 9B

/S, a nd Insoector's Signature National Board, State, and Endorsemnents Date:

6' - /&

f 200 -

N1

FORM NPV;1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provislons of-the ASME Code,Section III, DIvi8ion I

.Pg.1of 2

1. Manufactured and ceified'by Enertech, A Div. of Curtiss-Wdght Flow Control Corp., 2950 Birch St., Brea, CA 82821 (name and address of N Certificate Holder)
2. Manufactured for Calvert Cliffs Nuclear Power Planit, PO Box 17323. Baltimore, MD 21297-1323 haine and address of Purchaseri
3. Location of Instalan Calvert Cliffs nuclear Power Plant; 1650 Calvert Cliffs Parkway, Lusby,.MD.206S7.

(name an4 iddress:

4. Model No., Series No., or Typ KRV Drowing MD21083 Rev.

A None S. ASME Code,Section III; Division t:

1995 1996 2

.None (edition)

(addenda date)

Iless)

ICode Case no.)

6. Pump or valve NNorhini Inlet size 2

Outlet size

((in.)

7 MateIal Bdy SA-479Type316 Sonnet N/A Disk US-564Tiye30H1075 Bolting.

(b (c

(al Wb (cW d

(el Cert.

Nat' I Body Bonnet Disk.

Holder's Board Serial Serial Serial Serial No.

No.

No.

No.

No.

11311 None KTV-3327 None KITW-3335 11312 None KTV-3328 None KTW-3336 11313 None KTV-3329 None...

'TW3337 11314 None KTV-3330

.None KTW-3338 11315 Nne-.

KTV-3331 None KTW-3339 11316 None*

KTV-3332 None ITW-3340 11317 None KTV-3333 None '

T..K:FW-3341 11318 None KTV-3334 None KTW-3342

.7 Supplemental Information In form of lsts, sketches, or drawings may be used provided (1) size Is B X x I1I, (21 Informatioe in Items I through 4 on this Data Report Is included on each sheet, 13) each sheet Is numbered and the number ef sheets Is recorded at the top of this for3n.

(12/88)

This form lEOWO371 may be obtained from the Order Oept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007.2300.

REPFUNT U93

FORM NPV-t (Bock -

Pg. 2 of 2..

11311 thru Ce'rtificate Holder's Serial No.

11318

.8 Design conditiona 1600 psi 30 F or valve pressure class 1500 (pressure).

Itemperaturel

9. Cold working pressure 3600 psl at tOOF
10. Hydrostatic test 5400 psi.. Disk differantial test pressure N/A i

px-1: Rlemarks: Qty. 8, Enertech Project Number 810048 I

CERTIFICATION OF DESIGN Design Specification certifted'by John R. Sponsel, I P.E. State MD Reg. no.

17308 Design Report certified by Ira J, Silverman P.E. State CA Reg. no.

23241 CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASMi Code, Section lIl. Division 1.

N Certificats of Authorization No N2826E bate Edt A Div. of Curtfss-Wwfght Flow Corrro Cbrp.

Big

1.

1 IN Certificate fHolder)

(authorizud represntatv I

.1 I

CERTIFICATE OF INSPECT1iON

.1, the undersigned. holding a valid commission Ipssued by the National Board of Boller and Pressure Vessel Inspectors and the StatS or Province of Calaforia end employed by HSB CT of Connecticut have Inspected the pump, or valve, described In thisflita Report on 1 -

Zq 4~* -

!and stats that to the best of my knowildge and belief, the Certificite Holder has con-structed this pump, or valve, In accordance with the ASME Code, Section ill, Division 1.

By signing this certificate; neither the Inspector nor his employer mekei any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any klhd aIsIng from or connected with this Inspection.

Date

/

42I 3igned mLissona 14q4-lAuthorized Inspector)

[Nat'l. 8d. (Incl. endorsements) and state or prov. and no.)

(11 For manua'ly operated valvesvonly.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-046b, MWO No. 1200203109 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

Two (address)

4. Identification of System:

System Number 052 SystemName:

Safety Injection 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME Name of Componet Piping System Pipe Nut Allthread Rod Flange Nut Name of Manufacturer Bechtel Albert Pipe Supply Co. Inc.

Mackson Inc.

Mackson Inc.

DuBose National Energy Services Inc.

Mackson Inc.

Manufacturers Serial Number 2"DC-2-1003 F-5630 Ht.#: 496481 408227 Ht.#: S44018 410155 Ht.#: S20751 411588 Ht.#:31438 Code: BQL 400066 Heat Code:

JKX Na Boa tional Other ard No.

Identification N/A

  1. 13 High Pressure Safety Injection Pump Mini Flow Recirc.

to Refueling Water Tank N/A Pipe, 2 In., Sch. 80, ASME SA-376, Tp. 304 N/A Nut, Heavy Hex, 7/8 In. X 9 TPI, ASME SA-194 Cr. 2H N/A Rod, Aulthread, 7/8 in. X 9 TPI, ASME SA-193 Gr. B7 N/A Flange, 2 In., 1500 lb., Raised Face, Socketweld, ASME SA-182, Gr. F316 N/A Nut, Heavy Hex, 7/8 In. X 9 TPI, ASME SA-194 Gr. 2H Year Built 1975 1970 2002 2003 2003 2000

Repaired, Code Replaced, oi Stamped Replacemen (Yes or No)

Repaired/Repi No aced Replacement Replacement Replacement Replacement Replacement No No No No No

7. Description of Work:

This plan was for the piping, fittings, hanger support work and fasteners needed to support the replacement of 1-CKVSI-426, #13 High Pressure Safety Injection Pump Mini Flow Check Valve.

8. Tests Conducted:

Hydrostatic:n PneumaticO Nominal Operating Pressure:

Inservice: E Leakage: R Functional: n Pressure:

1310 psi.

Test Temperature:

82 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 1 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi Svstem Leakage Test of the affected comoonent was performed durina the svsteml conditions listed in section 8. of this report.

Code Case N-416-2 was invoked to satisfv Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

RepalrlReplacement Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A V

Charles H. Ballard Engineering Technician Signed:

Date:

6/15/2004 Owner`r (iwnes Designee, Title i' Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period

.2.23 04 to C-M-O.,

and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bLordL A. 5 N-71A rY AlIz.

5-04J AMvJ6IS PM

-o a

-A(

D Inspector's Signture Date:

6v-14 200 Commissions: AXJ3

&'3/, /10 /7/ 71 4

/1

,vi J A. -77' e National Board, State, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl Calvert Cliffs Nuclear Power Plant, Inc.

1. Owner:

Date:

6/15/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 0 (address)

Calvert Cliffs Nuclear Power Plant

2. Plant:

(name)

Unit:

One R&R No. 2003-1-056, MWO No. 1200203364 1650 Calvert Cliffs Parkway; -Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

(P.O. no.,job no., etc.)

Type Code Symbol Starmp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

One

4. Identification of System System Number 064 SystemName:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME B&PV Code Sect. III, 1968 Edition, Win. 1968 Add; Class A, CCases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Componet Name of Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Dresser Industrial Valve Co.

Nozzle Consumer Power Co. (Midland Plant Project)

Relief Valve Dresser Industries Inc.

Disc Dresser Industries Inc.

ReliefValve Consumer Power Co. (Midland Plant Project)

SN: BM-07953 N/A Unit One Pressurizer Safety Relier Valve 06045-GX AAA26 N/A Nozzle, Maxiflow Relier Valve, 2 1/2 In., Model 31739A, Dresser P/N 4231701N, ASME SA-182 Gr.

F347 411829 SN: BN-N/A Valve, Consolidated Closed 04373 Bonnet Maxlflow Safety; 2-1I2 In.

Mode! 31739A, only for RV 200 4dDK location.

409135 SN:*915F 6 N/A Disc, Maxillow Relief Valve, 2 1/2 In., Model 31739A, Dresser P/N 1840404N, ASME SB-637 Gr. 688 06045.GX AAA19 N/A Cannibalized pressurizer relief valve, SIN BN 04376 1977 Repalred/Repl aced 1987 Replacement 2004 Replacement Yes Yes Yes Yes Yes 2003 Replacement 1987 Replacement

7. Description of Work:

This plan was for the replacement of Unit-1 Pressurizer Safety Valve, 1-RV-200.

8. Tests Conducted:

Hydrostatic:n PneumaticG Pressure:

2260 psi.

Nominal Operating Pressure:

Inservice: l Leakage: i Functional: 0 Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

i

- r 0-56~-Sheetaof

~..

c' 3 6FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

A Section Xl System Leakaae Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Reolacenent conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A i dI/

  • 7v Charles H. Ballard Signed:

Engineering Technician Date:

6/15/2004 er or Ownes Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthis Owner's Report during the period 3 30-0' to 4_-__-_ _

_and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described-in this Owner's Report in accordance with the requirements of the ASME Code, Section )[.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

D044LD A. Se-/IA (tvL AU?.

DoffsSH jeiL2 S PrL T7-1741 Commissions: Ak3 '7g31 1 1/17/1 AJ

yL'-?7

/AU' M

_5 Insnectores Signature National Board, State, and Endorsements Date:

-- / 7 200.

FORM NVR-1 REPORT i tEPAIR [Z MODIFICATION i OR REPLACEMENT

]

OF NUCLEAR PRESSURE RELIEF DEVISES

1. Work performed by Dresser Flow Control, Dresser Inc. La. Hwy 3225 @ Us Hwy 167 N 4118291408989 01287030101284080

( name of organization)

(P.O. no., job no., eta)

P. 0. Box 1430 Alexandria, Louisiana 71309-1430 (address)

2. Work performed for Baltimore Gas & Electric Co. 1650 Calvert Cliffs Parkway Lusby, Maryland 20657

( name and address )

3. Owner Baltimore Gas & Electric Co. 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 (name)

(address)

4. Name, address and Identification of nuclear power plant Baltimore Gas & Electric Co. Calvert Cliffs Nuclear Station 1650 Calvert Cliffs Parkway Lusby, Maryland 20657
5. a: Repaired pressure relief device:

Safety Valve b: Name of manufacturer Same as item 1 above c: Identifying nos.

31739A BN-04373 N/A STEAM 2-1/2" 1977 (type)

(mrs serial no.)

(Nat'l. Bd. No.)

(service)

(size)

(yearbultt) d: Construction Code ASME Section III 1968 Winter 1968 W 1968 Art. 9 A

(name/section/division)

(edition)

(addenda)

(Code case(s))

(Code Class)

6. ASME Code Section Xl applicable for in service inspection:

1998 NO NONE (edition)

(addenda)

(Code Case(s))

7. ASME Code Section Xl used for repairs, modifications, or replacements:

1998 NO NONE (edition)

(addenda)

(Code Case(s))

8. Construction Code used for repairs, modifications, or replacements:

1968 W 1968 Art. 9 NONE (edition)

(addenda)

- (Code Case(s))

9. Design responsibility Same as item 1 above
10. Opening pressure:

2485 PSIG Blowdown (if applicable)

N/A

%. Set pressure and blowdown adjustment made at:

Wyle Laboratories, Huntsville, Alabama Using Steam

-lcataon (test medium) i 1. Description of work: (include name and identifying number of replacement parts)

Valve Was Disassembled, Inspected, Repaired Assembled, & Tested. Parts Replaced: Base P/N 1861505NC2015,S/N AAA-19; Nozzle PIN 18448060S278,SIN AAA26; Bellows PIN 1840801N, SIN 2872/2-2; Disc PIN 1840404N, S/N ADK-59; Guide/Support Plate Gaskets PIN 3831018N, Cotter Pins P/N 2220219, & Adi. Ring Pin Gaskets PIN 3610508.

12. Remarks:

Base was modified on owner's purchase order 411554, Dresser order no. 31-52548-0.

CERTIFICATE OF INSPECTION I, P.- a )

W.l A /

certify that to the best of my knowledge and belief the statements made in this report are Correct and the repair, modification or replacement of the pressure relief devices described above conforms to Section Xl of the ASME Code and the National Board Inspection Code 'VR' and 'NR' rules.

National Board Certificate of Authorization No.

VR-70,95,97-118 & 12G-124 to use the 'VR stamp expires 6-29-2004 National Board Certificate of Authorization No.

NR-45 to use the M Ra stamp expires 630-2005 Date

/t4 O (

Same as Item 1 above.

Signed (name of certificate holder )

(authorized representive)le)

CERTIFICATE OF INSPECTION I,

,j k?,

-f/OS,*4b,

, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of Louisiana and employed by Hartford Steam Boiler Inspection and Insurance Co.

of Hartford, CT have Inspected the repair, modification or replacement described In this report on and state that to the best of my knowledge and belief, this repair, modification or replacement has been completed in accordance with Section Xl of the ASME Code and the National Board Inspection Code "VR' and

'NR' rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or Implied, concerning the repair modification or replacement described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or ss ao 8

nd arising from or connected with this inspection.

Date Signed Commissions.424= A lkb' LrcJ (National Board (i.

endorsements),

iurisdiction, and no.1

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT PuR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code, Section Ill Not to Exceed One Day's Production Pg.Iof 2

Dresser Flow Control, Dresser Inc. La. Hwy 3225 @ US Hwy 167 N

1. Manufactured and certified by P. 0. Box 1430 Alexandria, Louisiana 71309-1430 (name and address of NPT Certificate Holder) _
2. Manufactured for Calvert Cliffs Nudear Power Plant P.O. Box 17323 820 G & E Building Baltimore Md 21297-1323 (name and addes of pwdhaser)
3. Location of installation Calvert Cliffs Nuclear Plant, 1650 Calvert Cliffs Parkway Lusby Md 20657 (nam andm address)
4. Type OS417 SB637 (Inconel X-750) 170 KSI NIA 2003 (drawing no.)

(matl spec, no.)

tensile strength)

(CRN)

( yearbult)

5. ASME Code Section III, Division 1:

1968

- Winter 1968 1

N/A

( edition)

(addenda date)

(cdass)

(Code Case no.)

6. Fabricated In accordance with Const. Spec. (Div. 2 only)

NJA Revision N/A Date NIA (no)

7. Remarks:

Serial Numbers Are Used In Ueu Of NPT Stamping.

8. Nom. thickness (in.)

N/A Mi ndesign thickness (In.)

NiA Dia. ID (ft. & In.)

N/A Length overall ( ft & in.)

N/A

9. When applicable. Certificate Holders' Data Reports are attached for each item of this report Part or Appurtenance Serial Number National Board No.

In Numerical Order (1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(13)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

ADK59 4

t 4

I I

I l

l.

I.

1-

10. Design pressure N/A psi Temp.

N/A

  • F.

Hydro. Test pressure 4500 PSIG at temp. OF

  • Supplemental information in the form of lists. Sketches, or drawings may be used provided (1) sIze is 8-1/2 x 11, (2) information In items 2 and 3 on this Data Report Is ninduded on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

4 1

FORM N-2 (Back -

Pg. 2 of 2

)

Certificate Holder's Serial Nos.

ADK59 and CERTIFICATION OF DESIGN Design specificaffons certified by NZA P.E. State N/A Reg. No.

N/A (wten applicable)

Design report* certilled by NWA P.E. State N/A Reg. No.

NIA (when applicable)

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this ( these)

DISC conforms to the rules of construction of the ASME Code, Section Iii, Division 1.

NPT Certificate of Authorization No.

N-2434 Expires

_012004 Date 3/i 103 Name SEE LINE I Signed i*V W)

I

{ NPT Certificate Holder)

(authorized represewtattva)

CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of LOUISIANA and employed by H. S. B. I. & i. Co.

of HARTFORD, CT.

have Inspected these items described in this Data Report on 1/M o0k..I

, and state that to the best of my knowedge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code,Section III, Division 1. Each part listed has been authorized tor stamping on the date shown above.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or imptied, concerning the equipment desraibed in this Data Report. Furthermore, neither the Inspector nor his employer shall be gable In any manner for any personal injury or property damage or loss of any kind arising from or connected witht p pecon.

Date 3

//

Signed Al f

Commissions f AMMa WM Mwf hp s

Imaectnr I I NM.04 4 E

n d,.-4 e

n an

-I zs

% o.-..Go.svaw

-}.-

Se1w CRX dn e

I 

A el -. 71r 4c-k I

DSO A'. 3ei FORM NV-I N CERTIFICATS HOLDERS' DATA REPORT FOR SAFETY AN4 SAFETY RELIEF VALVES*

(AS REQUIRED IT THE PROVISIONS OF THE ASKE CODE, SECTION III, DIV. 1)

1. RANUFACTURED if DRESSER INDUSTRIAL VALVE A IXSTR. DIV.

Ml6Ayl7ft NOWMN ALEWDRIi.

1.603IfiANA (ANAE AND ADDRESS OF ItDRTI FICATE HOLDER)

2. MANUFACTURED FOR Babcock & Wilcox Pwr-Gen.Div.qP.0.Box 1260, Lynchburg, Va. 24505 CRNAE AND ADDAESS OF PURCHIASER 01 OWNER)
3. LOCATIOR OF INSTALLATION Cons~ers Power Co., Midland Unit 1, Midland, Mich.

(NAME AND ADDRESS) 4 4CP-243Z 258 1978 (CRAN)

(BRAVING NO.)

(AT'L IRO.HO.)

(TEAR D9ILT3

5. VALVE 2

31739A-1-X2-0S278 (MODEL DO..SERIES NO.)

ITENT41111NE So. BN04376 (N CERTIFICATIHQLDER5'1SEIIAL.NC-.)

TYPE Safety ORIFICE SIZE..

CLASS J

(SAFETYSAFETY RELIEF;PILOT:POWER ACTUATED)

SOMINAL INLET SIZE 21/2 CUTLET SIZE 6"

1.

IICH

0. SET PRESSURE (PStC) 2500 STAMPED CAPACITY 297.845 L!S/HR.

SAT.STEAM HYDROSTATIC TEST (Psi)

INLET 3750 -SIG T. PRESSURE RETAINING PIECES SERIAL IN. OR IDENTIFICATION INCH INCII 670 RATED TEMPERATURE IDF

  • 3

% OVERPRESSURE SLOWDOWN (PSIG) 125 OUTLET 1050 PSIG (APPLICASLE TO VALVES FOR CLOSED SYSTEMR' HLY]

MATERIAL SPECIFICATION.

INCL. TYPE OR GRADE SODY SONNET 1Zffsx==

SUPPORT RaOS NOZZLE eISC SFRI19 WASHERS ADIUSTINO SCREW SPINDLE SPARIN DOLTING OTHER PIECES B/A/AAAIS SA-182 Gr. F316 B/AR/AAA40 SA105 TRIlIAAA26 SA-187 !Gr-r-347 RjrjAAT~nq SA-6137 !Gr. figg 15023 SA-105 M6356aSB-164 Class A t'17RR7

  • SA--479 er -

147 AH1210 AISI H21 ohtlct Elamse 79207 SA-182 Gr. F316 B^-^

-o f, a M.14 SA_194 Gr. 21 I

  • SUPPLEMENT SHEETS IN FORM OF LISTS.SKETCHES OR ORAWINOS MAY BE USED PROVIDED (I) SIZE IS 3-1/2"X II1 (2) INFORMATION IN ITEMS 1-2 0H THIS DATA REPORT IS INCLUDED ON EACH SHEET. AND (3) EACH SHEET IS NUNDERED AND NUMBER OF SHEETS IS RECORDED AT TOP OF THIS FORM.

i 1S

i j
sIii

FORM xWlI (SACX)

CERTIFICATE OF COMPLIANCE wl CERTIFY THAT THE STATEMENTS YADI IN THIS REPORT ARl CORRECT AND THAT THIS TALYI CONFORMS TO THE RULES OF CONSTRUCTION OF THE ASNE CODE FOR NUCLEAR PO1E1 PLANT COMPONENTS, SECTION III, DIV.I, 1971 EDITION. ADDENDA Sumer 1972 CODE CASE N/A DATE 1-26-78' SISNED Ball=

IV/p DATE(N CERTlFICATE 0OIDER)

P1ri pal Qual y Assurance Engiear OUR ASE CERTIFICATE OF AUTIIORIZATICO MD.

71-1747 UDSE THE M SYMBOL EXP!RES Ma 20, 1980 (NV)

(DATE)

CERTIFICATION Of 0131?t DESIGN INFORNATION 0N FILE AT 1resbr-Plarm, AlexAndrfia, TA..

STRESS ANALYSIS REPORT (CLASS I ONLY) ON FILE AT Dress2r Wlpant Al ewaredr4^

T.a_

DESISJI SPECIFICATIONS CERTIFIED AVI Johtn II U_ M 1.par PE STATE V4 r ln.

Rao. No.

4418 STRESS REPORT CERTIFIED ay' Y. S. Lai FE STATE T.nLouisina RE2.N3.

14105 1SISNATURE NOT REQUIRED-LIST NAME ONLY CERTIFICATE OF SHOP INSPECTION ITHE UNOERSIGNED. HOLDINS A VALID COMNISSION ISSUED BY THE NATIONAL BOA2D DF DOILIR AND PRESSURE VESSEL INSPECTORS ANO THE ;TATE OR PROVINCE OF LOUISIANA AND EMPLOYED BY TlE HARTFCA§ STal BST ILA 1..II.

COUP1W OF IANTFOPA, CCXN., HAVE INSPECTED THE PUIP.OR VALVE.DESCRIVD IN TNIS DATh REPORT ON 19.A AND STATE THAT TO TIHE DEST OF BY INOVLEDG1 AND SELIEF.TNS X CERTIFICATE HOLDER 1IAS CONSTRUCTED TVIS PUMP, OR.VALVE, IN ACCORDANCE WITH ItHE-ASME CODE FOR NUCLEAR FI1ER PLANT COMPONENTS.

BY SININ3 THIS CERTIFICATE. NEITHER THE INSPECTOR NOR HIS EMPLOYER KAXES ANY VARIIAIRYEXPAISSED OR IMPLIED, CONCERNINI THE £QUIPMENT DESCRIBED IN THIS DATA REPORT.FUTHERVORE.NEITHER. THE INSPECTOR NOR HIS EMPLOYER SHALL BE LIABLE IN ANY MAMNEA FOR ANY PERSONAL INJURY OR PROPERTY DAMASE OR A LOSS OF ANiT KIND ARISINI FO OR o

Dnp; E. WIT SIS IB FICTION.

DAtE _102 I In' I4

'fly SDAMEP.

A&P T tw e

COEMISSION SNational Board No. 7876 I SPECTOR)

.NATOL.DR.STATE PROY.AN ND.)

V

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6115/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-056a, MWO No. 1200203364 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Syrbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Piping System Bechtel 21/2"CC-10-1007 N/A

  1. 11 Pressurizer Piping to Safety 1975 Repalred/Repi No Relief Valve 1-RV-200 aced Nut Mackson Inc.

409779 Heat Code:

N/A Nut, Heavy Hex, 11/8 In. X 8 TPI, 2003 Replacement No AGM ASME SA-194 Gr. 7 Rod Nova Machine 38612 Heat Code:

N/A Rod, Allthread, I 1/8 In. X 8 TPI, 1999 Replacement No Products Corp.

MWX ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the replacement of pressure retaining fastener materials to assist in the replacement of Unit-1 Pressurizer Safety Valve, 1-RV-200.

8. Tests Conducted:

Hydrostatic:E Pneumatic]

Nominal Operating Pressure:

Inservice: E Leakage: 1 Functional: I]

Pressure:

N/A psi.

Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

.nr C}

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-1 Visual Examination of the reDlacement threaded fasteners was performed to satisfy Section XI Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

/n/a, g

Engineering Technician Date:

6/15/2004 Owner-o'wner's De rinee, Titr Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 39 V Y to 6

,11

@e

. and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DO ddZ-0 4 - S14-ePoMr f,,=t

,V.

EUOH,%) A4OiCfs pat-GA F

Commissions:

4J13 7?S3/, /)

/1 7/

AWY Tnqntnr'qs1;in hatre National Board, State, and Endorsements Date: 6 -/7 --------

1 f-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

6118/2004 Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2004-1-027, MWO No. 1200203390 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Synbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

System Number 064 SystemName:

ReactorCoolantSystem 5.(a) Applicable Construction Code and Class:

ASME B&PV Code Sect. 1I1, 1965 Edition, Win.1967 Add; Class A CCases: 1335-2, 1336, 1359-1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Componet Name of Manufacturer Manufacturers Serial Number National Board No.

Other Identification Pressure Vessel Combustion Engineering ICI Flange ABB Combustion Engineering Plug BGE CCNPP Shops Vessel SN: 67107; Head SN: 67207 95991-GX SN: 94-0855 0200101511 SN:

011, 012 & 013 20911 Unit PI Reactor Vessel and Head N/A Flange, S In., 2500 lb, Large Tongue, Blind with 6 holes for ICI's, ASTM A-182, Gr.F321 N/A Plug, Incore Detection Seal, Dwg.

12148-03,ASTM-A276, Ty316 SS 1971 Repaired/Repl aced 1994 Replacement 2001 Replacement Yes No No

7. Description of Work:

This plan was for the installation of dummy stainless steel ICI plugs and a new In Core Instrumentation Flange on Unit #1 Reactor Vessel at the #4 ICI penetration.

8. Tests Conducted:

Hydrostatic:E Pneumaticfl Pressure:

2260 psi.

Nominal Operating Pressure:

Inservice:

l Leakage: b Functional: a]

Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Simertinn Yl Prp-.qprvirA Ngl Rqnutiremnts A Rpreninn YIX Svrtm I ank-n Tt Ta f Ikf

g!ffg%&tofr41 &r^mn,%nfn#

Iu~ \\. -

Ac o

  • _*--lllu.

-tv

,\\

ow>g1

  • Io a

wlvI&t was performed durinq the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

Repair/Replacement Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Signed:

W Charles H. Ballard Engineering Technician Date:

6/18/2004 Owner ofOwner's Designee, Ttkle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period

/- a 7

'if

-0 to 5- /0 -09

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DoAd-t A. 5"194 SrZ A2.R, A,4kI1Al C04-71;S 7-L-F4C 5e.

-1 A

-la 4

Inspector's Sign;ture Date:

2" 00-1-u 200 Commissions: AJIB ;;

J X.

i/&T A

Nai

/

n 7

o7 9

Ste a

/

Ere National Board, State, and Endorsemnents

'~I---

ii FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

6/1512004 Sheet 1 of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2004-1-010, MWO No. 1200203521 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

System Number 083 System Name:

- Main Steam & SG Blowdown 5.(a) Applicable Construction Code and Class:

ASME B&PV Code Sect. III,1977 Edition, Win.1979 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

- ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Fisher Controls 8252433436 Plug, Primary Fisher Controls Intl., Inc.

76678-GX SN:

LB3717-1 N/A

  1. 11I Steam Generator Auxiliary Feed Water Pump Steam Supply Control Valve N/A Plug, Primary, 6 In. Control Valve, ASME SA-479, Gr. 316L /

Stellite, BGEDRWG #1229040018, Item 67 1980 RepalredtRepl aced Yes 1992 Replacement Yes

7. Description of Work:

This plan was for the work and part needed to rebuild 1-CV-4070, #11 Steam Generator Auxiliary Feed Water Pump Steam Supply Control Valve.

8. Tests Conducted:

Hydrostatic:[]

Pneumatico Pressure:

NiA psi.

Nominal Operating Pressure:

Inservice: E Leakage: f Functional: [

Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in suODort of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Dso e

iX e4 Charles H. Ballard Signed:

5, Engineering Technician Date:

6/15/2004 Owner orT er's rs-igne'e itle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod d-/a

- 0M to S -t-e'l

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected w'th this inspection.

45.

,:OR-

/R af

=

iH JO A;?-L'AS PEZ 7.L.-fLFYAX Commissions: AJ 3r 983, /10//7/, -'J//

Inspectores Signature National Board, State, and Endorsements Date: 6-14'*

200O4

003B-P21C18573 FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAteM 0001 NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code,Section III Not To Exceed One Day's Production Pg.

of

1. Manufactured end certified by FISHER CONTROLS INT'L INC, KAPSHALLTOWN, IOWA 50158 InaW and 8sd&s ot NPT Certifcate 14old0f
2. Manulacturedfor Baltimore Gas & Electric Co.. Box 1535, Baltimore. Md. 21203 sname and address of ovicnlaserI
3. Locationofinstallation Calvert Cliffs Nuclear Station. Lbsby. Md. 20657

.nAn am lcddressi

4. Type 34A2071 Rev G SA-479-S31603 70.0 KSI N/A 1993

-draweng 1.1

'Mat il spec. noJ tnflStr*Ngthl

-CNI ear bwlt

5. ASME Coda, Section III:

1977 Winter 1979 2

N/A a.0t.Ons addends alts iclasse Code Case moI

6. Fabricated in accordance with Const. Spec. IDiv. 2 onlyl N/A Revision N/A Date N/A

'no.,

7. Remarks:

PARTS ARE FOR VALVE SIN 8252433-436

8. Nom. thickness in. l NIA Min, design thickness (in.

A NA Die. ID fit & in.)

NLA.-

Length overall (ft

& in.I N/A

9. When applicable. Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance

-N efc Part or Appurtenance National Serial Number 1

4O o.No II Serial Number Board Number

.m.NlOideS

! § in Numerical Order Heat Number I

i1 LB3717-1 31333-1

'26)

12) 1(27) 13!

!128)

I

14)
429) m1.

-I

161, (73

'8) 19)

(10) t111 I-

.aVP 131)

(32)

(33t 1341 1351

(361 1

137) 1131

_138) t14) 139) -

015 I

(403 116.

141) 71 142 11i_..).

143)

  • 191 144 120) 345)

(21) 1461 122) 147)

.123)

  • 148)
  • 124)
149)

'125)

(i0-

10. Design pressure 1000 psi.

Temp.

580 F.

Hydro, test pressure N-A at temp. F j.1

  • ponatiep~e
  • Supplemental informatioin the form o lists. sketches. or drawings may be used provided 311 site is 8X K t 121 2Informtion in stems 2 and 3 on ths Data Reort is included on each sheet. i31 each sheet is numbered and the numboer of sheets Is recorded at the top of this form.

112/86)

This form (E000403 may be obtained from the Order Oct.. ASME. 22 Low Dive. Box 2300. Fasirfield, NJ 07007.2300.

'I- -I FORM N-2 (back)

Mfr. Serial No.

CERTIFICATION OF DESIGN Design specifications certified by Robert F. Ash PE State Md.

Rel n.

9198 Design report certified by N/A PE. State N/A Fel.no.

N/A l

~whefl Ip4.aob~e)

CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this Ithese)

Primary Plug conforms to the rules of construction of the ASME Code, Section Ill.

NPT Certificate of Authorization No.

1930 Expires 11-18-95 Date 7-:

Name FISHER CONTROLS INT'L INC Signed a ra_

NPT Cert.ieste Holdeu Ilutihonzed eptesontatZ CERTIFICATE OF SHOP INSPECTION

  • tigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ofI dA and employed by HARTFORD S.B.I & I CO.

of HARTFORD.

CONN have inspected these items described in this Dats Repor on_

7 S

.and state that to the i best of my nowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code. Section l Ill. Each part I sted has been authorized for stamping on the date shown above.

By signing this certificate. neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described In this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising fram or connected with this inspection.

Date 7-2? 3 Signed 7 i.

(

4 Commissions

° ;a4*

tAuthenzed Inetorl KN&OC M. 1Inal. endoreamonisl staes at Sav. ane nol!

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6/1712004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-032, MWO No. 1200203958 (address)

(P.O. no.. job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of Systemn System Number 064 System Name:

Reactor Coolant System 5.(a)Applicable Construction Code and Class:

ASME B&PV Code Sect. 1I1, 1983 Edition, Sum. 1983 Add; Class I (b) Applicable Sect XM Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

RCP Seal Sulzer Blngham SN: 1C869 NB 1294

  1. 12A Reactor Coolant Pump 1988 Repaired/Repi Yes Inc.

Mechanical Seal aced Seal BGE CCNPP Shops 1200202602 SN:

NB 1290 Seal, Cartridge Assembly (RCP) 2003 Replacement Yes IC870 875B-3V Complete Sulzer Blngham per FCR 87-0074

7. Description of Work:

This plan was for the replacement of the mechanical seal on #12A Reactor Coolant Pump.

8. Tests Conducted:

Hydrostatic:E Pneumatics Nominal Operating Pressure: -

Inservice: E Leakage: 0 Functional:E Pressure:

2260 psi.

Test Temperature:

532 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 3 X FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was oerformed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

Repalr/Replacement Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Signed:

Charles H. Ballard Engineering Technician

_Date:

6/17/2004 Owner or orwerss ignee, T ite Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod 6' -A' 3 to 6-/1 69y

,andstatetothebestofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

OHAJ 4J*Zl Pg z-f Comnissions:

A16\\ 9A-3), 1t9 11/7/, FhJ N a t io7 7

Bo a St ate and E ndI National Board, State, and Endorsemnents D

Inspector's Signature Date: _

_I 200 Y

T

-d FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Date:

611512004 Sheet I of 2

2. Plant:

(address)

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-008, MWO No. 1200203966 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

One

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME B&PV Code Sect. 111, 1968 EditIon, Win. 1968 Add; Class A, Cases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification ASME

Repaired, Code Year Replaced, ox Stamped Built Replacemen (Yes or No)

Valve Dresser Industrial Valve Co.

Nozzle Dresser Industries Inc.

Relief Valve Dresser Industries Inc.

Disc Dresser IndustrIes Inc.

SN: BM-07952 86592-GX SN:

AAB60 404679 SN: BM-07948 95597-GX SN:

ACM73 N/A Unit One Pressurizer Safety Relief Valve N/A Nozzle, Maxiflow Relief Valve, 2 1/2 In., Model 31739A, Dresser P/N 4231701N, ASME SA-182 Gr.

F347 N/A Valve, Consolidated Closed Bonnet Maxiflow Safety; 2-1/2 In.

Model 31739A, only for RV 201 location.

1977 Repaired/Rep]

aced 1987 Replacement 2002 Replacement Yes Yes Yes Yes N/A DIsc, Maxinlow ReliefValve,2 1/2 1995 In., Model 31739A, Dresser P/N 1840404N, ASME SB-637 Gr. 688 Replacement

7. Description of Work:

This plan was for the replacement of Unit-1 Pressurizer Safety Valve, 1-RV-201.

8. Tests Conducted:

Hydrostatic:[

PneumaticO Pressure:

2260 psi.

Nominal Operating Pressure:

Inservice: O Leakage:R Functional: E Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Q.Crfinn YX Prga:hfrui' NIF fl Pgn.,;rnmmnta A Section Xi System Leakage Test of the affected CO Donent tJvtIflu I

I P I

-I%-

-v4-I

-av II,-J.

was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

Repair/Replacement Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Z" " /

n'1. /

Signed:

Charles H. Ballard Engineering Technician Date:

6/15/2004 Owner or Owner's Designee, Tie T Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period

//-f 2)- 0 3 to 6 -/0 -0 4

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

iDOA)41-0, A.

j.nM fitZ,Yi2i.

ZYOH-A10f-2-IS pL'YZ-ff Commissions: AJ157953 1AfO/17/, 4Ad//

Inspector's Signature Date:

7 -/6 200 1 NJ ationa Boad a0 / a nd S

National Board, State, and Endorsements

Alexandria. Louisiana USA FORM N-2 OR NPr CERTIFICATE HOLDERS' DATA REPORT FOR IDOENMCAL NUCLEAR PARTS AND APPURIENANCES-As Required by the Provisions of the ASME Code,Section III, Div. 1 Not to Exceed One Day's Production Page l of 1 Dresser Industries, Inc., Dresser Valve & Controls Div. Industrial Valve Operations

1. Manufactured and certified by Intersection Hwy. 167 & 3225 North, Alexandria, LA 71309-1430 (Name and Address of Certificate Holder)
2. Manufactured for Baltimore Gas & Electric P. 0. Box 1635 Baltimore, MD 21203-1535 (Name and A"dres of Purchaser)
3. Location of Installation Baltimore Gas & Electric 1650 Calverts Cliffs Parkway Lusby, MD 20657 4.

5.

6.

7.

(Name and Address)

Type OS417 SB637 Inconel X750 NIA NIA (Drawing NoJ (Mat'l. Spec. NoJ frensile Strength)

(CRNM ASME Code, Section III:

1968 Winter 1968 A Article 9 (Edition)

(Addenda)

(Class)

Fabricated in accordance with Const. Spec. (Div. 2 only) N/A Revislor Remarks:

N/A No.)

1995 (Year Built)

NIA ICode Case No.)

I N/A Date N/A 8.

9.

Nom. thickness (in.)

NIA Min. design thickness lin.)_NLfADia. ID (ft.&in.)NIA_.Length overall (ft.&in.)l N/A When anolicable. Certificate Holders' data renorts are attached for each item of this report.

t Part or Appurtenance National Board No.

Serial Number In Numerical Order tll Af-7M 71 I)

ACM 79 t12 A MtP 72 141 ALM 74 IA)1 AM 7R_

IR) fill 119)

(IMs 11 7

__}

II Mdi}

Par or Appurtenance National Board No.

Sorial Number In Numerical Order 19A7 19pi th90 I'M

{ 12fl

  1. 191,0 till f4Q1 12411 fI2~

127)

'IA)

( 4 9 1_

  • 4 4 1 14 S ;)

I4415 _

I 47 l'~

1 O.Deslgn Pressure N/A psi Temp. N/A

'F Hydro test pressure 4500 at temp. 'F

  • Supplemental information in form of lists, sketches or drawings may be used provided, 41) size Is 8X xI 1, (2) information in items 2 & 3 on this data report is Included on each sheet, (3) sheet Is numbered and number of sheets is recorded at top of this form, and (4) each additional sheet shall be signed by the Certificate Holder and the ANI.

r---_

CERTIFICATE OF DESIGN Design specifications certified by N/A P.E.

NIA Reg. no.

NIA (when applicable)

Design report' certified by NIA P.E.

N/A Reg. no.

N/ilA CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that these disc conform to the rules of construction of the ASME Code, Section Ill.

NPT Certificate of Authorization No.

N-2434

. Expires Mau 20. 1995 Date 4/2 Lqs Name See Line 1 Signed (NPT Certificat. Holder)

(authorized repros CERTIFICATE OF SHOP COMPLIANCE

1. the undersigned, holding a valid commission by the National Board of Boiler and Pressure Vessel Inspector and the state or province of Louisiana and employed by The Hartford Steam Boiler lnpect n_ Insurance Co.,

of Hartford, CT, have Inspected these items described in this data report on ________S

. and state that to the best of my knowledge and believe, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section Ill. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied concerning the equipment described In this data report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date Signed

,M I

Commissions (At hoidzed Inspectorl INalt. 8d. Onol. endorsements) state or prov. andno.)

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-008a, MWO No. 1200203966 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 064 SystemName:

Reactor Coolant System 5.(a)ApplicableConstructionCodeandClass:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect Xl Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Piping System Bechtel 2 1/2"CC-10-1008 N/A

  1. 11 Pressurizer Piping to Safety 1975 Repalred/Repl No Relief Valve 1-RV-201 aced Nut Mackson Inc.

409779 Heat Code:

NIA Nut, Heavy Hex, 11/8 In. X 8 TPI, 2003 Replacement No AGM ASME SA-194 Cr. 7 Rod Nova Machine 38612 Heat Code:

N/A Rod, Allthread, 1 1/8 In. X 8 TPI, 1999 Replacement No Products Corp.

MWX ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the replacement of pressure retaining fastener materials to assist in the replacement of Unit-I Pressurizer Safety Valve, 1-RV-201.

8. Tests Conducted:

Hydrostatic:E PneumaticO Nominal Operating Pressure:

Inservice: E Leakage: fl Functional: fl Pressure:

NIA psi.

Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-I Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Relacerment conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A A~<(2 5 ~1I.&/LjCharles H.

Ballard Signed:

Engineering Technician Date:

6/15/2004 Owner or Owner's Designee, Tite Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthis Owner's Report during the period /.2 -

O' to 56 -/°09

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

()Q~s A X SHA4-P//$

F. A/.

t o

HU Commissions:

JI3 V 8q

/5 0

/7t A e//

Al /S / X779' A1,0 /X /

National Board, State, and Endorsements Date:

200

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

6/1512004 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)

Calvert Cliffs Nuclear Power Plant (name)

2. Plant:

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-057, MWO No. 1200204093 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

1650 Calvert Cliffs Parkway, Lusby, MD 20657 One (address)

4. Identification of System.

System Number 064 SystemName:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME B&PV Code Sect. III, 1968 Edition, Win. 1968 Add; Class A, CCases 1581, N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, ox Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Dresser Industries BM-07951 N/A Unit H1 Pressurizer Electromatic Power Operated Safety Valve 1996 Repaired/Repi aced No Electromatic Relief Valve Dresser Industries 402603 SN: BS-Inc.

07325 NIA Valve, Pressurizer ERV, 2 1/2 In.

2001 Replacement 2500 lb., Consolidated Electromatic, P/N: 31533VX-30 XFF1-NC2005 No

7. Description of Work:

This plan was for the replacement of Unit-1 Pressurizer Power Operated Relief Valve 1-ERV-404.

8. Tests Conducted:

Hydrostatic:]

Pneumatic{]

Pressure:

2260 psi.

Nominal Operating Pressure:

Inservice: 17 Leakage: i Functional: E]

Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed durina the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed:

/

Engineering Technician Date:

6/15/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 8-a 1-3 to 6 -//-a

. and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection DOt4a-A.31,f li4 v ql.o AceJ AiO2rZ-Ifi PbLYZ 7,S-7-C-A4q--

Commissions:

4AC 9 0'3 /, AfD//7/

4.A///

,J

,Nl775 Ai l

oaSt S

Imnecor'sSi~ntureNational Board, State, and Endorsements Date:

A -

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl Calvert Cliffs Nuclear Power Plant, Inc.

1. Owner:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Date:

6/1512004 Sheet 1 of 2

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One R&R No. 2003-1-057a, MWO No. 1200204093 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

(P.O. no.,job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

One

4. Identification of System:

SystemNumber 064 SystemName: - Reactor Coolant System 5.(a)ApplicableConstructionCodeandClass:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Componet Name of Manufacturer Manufacturers Serial Number National Board No.

Other Identification Piping System Bechtel 2 1I2"CC-10-1004 N/A

  1. 11 Pressurizer Piping to 1-ERV-404 1975 Repaired/Repi aced No Nut Nova Machine Products Corp.

Rod Nova Machine Products Corp.

38612 Heat Code:

MVJ 38612 Heat Code:

MWX N/A Nut, Heavy Hex, 1 1/ In. X 8 TPI, 1999 ASME SA-194 Gr. 7 N/A Rod, Allthread, 1 1/8 In. X 8 TPI, 1999 ASME SA-193 Gr. B7 Replacement Replacement No No

7. Description of Work:

This plan was for the replacement of fastener materials to support the replacement of the Unit-1 Pressurizer Power Operated Relief Valve 1-ERV-404.

8. Tests Conducted:

Hydrostatic:E]

PneumaticO Pressure:

N/A psi.

Nominal Operating Pressure:

Inservice: E Leakage: [

Functional: E Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-1 Visual Examination of the replacement threaded fasteners was Performed to satisfy Section Xl Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Reolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/15/2004 Owner or Owneres Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9-aS -

__ to 6 //-OY

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

4M-4Z/S Commissions:

Ai13 913/

, A1f) 1274,.P`/

-=

tn nIS A77oa A

n Edrmn Ins~ctoss sznaureNational Board, State, and Endorsements Date:

(a -0 /

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Date:

6118/2004 Sheet I of 2 (address)

Calvert Cliffs Nuclear Power Plant

2. Plant:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant De (name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (addirss)

Unit:

One R&R No. 2003-1-058, MWO No. 1200204377 (P.O. no., job no., etc.)

,pt.

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

One

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME B&PV Code Sect. 1I1,1968 Edition, Win.1968 Add; Class A,

-CCases 1581, N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 EditIon

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers National Serial Number

- Board No.

Other Identification Valve Dresser Industries BM.07950 N/A Unit #1 Pressurizer Electromatic Power Operated Safety Valve 1975 Repalred/Repl aced No Electromatic Wyle Laboratories 412522 SN: BY-Relief Valve 77325 N/A Valve, Pressurizer ERV, 21/2 In.

2004 Replacement 2500 lb., Consolidated Electromatic, PIN: 31533VX-30 XFFI-NC200S No

7. Description of Work:

This plan was for the replacement of Unit-1 Pressurizer Power Operated Relief Valve 1-ERV-402.

8. Tests Conducted:

Hydrostatic:n PneumaticO Pressure:

2260 psi.

Nominal Operating Pressure:

Inservice: n Leakage: i Functional: E Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xi Pre-Service NDE Requirements.

A Section Xi System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

G Engineering Technician Date:

6/18/2004 Owner or owneis Designee, Trile Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period

? -a / - 0 3 to 6 /-C* O9

.and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DWJ4--

'1.SH1 Sad" r F0tZ H12 MA10VJ^- 6Co7S Commissions: /

9/i 13 (of!) //63 6e Siatur Nional Bard, Ste a m1 aInspector's Signature National Board, State, and Endorsements Date:

( - -L-

-- 2O-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl.

Calvert Cliffs Nuclear Power Plant, Inc.

1. Owner:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Date:

611812004 Sheet I of 2 (address)

Calvert Cliffs Nuclear Power Plant

2. Plant:

(name)

Unit:

One R&R No. 2003-1-058a, MWO No. 1200204377 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

(P.O. no.. job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

One

4. Identification of System:

SystemNumber 064 SystemName:

Reactor Coolant System 5.(a) Applicable ConstructionCode and Class:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Conponet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Piping System Bechtel 2 1/2"CC-10-1003 N/A

  1. 11 Pressurizer Piping to 1-ERV-1975 402 Nut Rod Nova Machine Products Corp.

Nova Machine Products Corp.

38612 Heat Code:

MVJ 38612 Heat Code:

MWX N/A Nut, Heavy Hex, 1 1/8 In. X 8 TPI, 1999 ASME SA-194 Gr. 7 N/A Rod, AlIthread, 1 1/S In. X 8 TPI, 1999 ASME SA-193 Gr. B7 Repaired/Repl aced Replacement Replacement No No No

7. Description of Work.

This plan was for the replacement of fastener materials to support the replacement of the Unit-1 Pressurizer Power Operated Relief Valve 1 -ERV-402.

8. Tests Conducted:

Hydrostatic:E Pneumaticj Pressure:

N/A psi.

Nominal Operating Pressure:

Inservice: E Leakage: El Functional: [

Test Temperature:

N/A Deg. F NOTE Siujppemeiinl sheetsm nform of lists, sketches, or drawings may be used, provided[(l1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/18/2004 Owner or nwrer' es~lignee,ritle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period Y/ -2 kO091 to 6 -/ ov /

and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DoMJ/f-L-A q.

7

- S 4'//V F

, C IV -ZIVIAJ C6

-S Pht -

82L Commissions: A113 7

/.

I/S A ) /4 65 Insnector's Signature National Board, State, and Endorsements Date:

=L --

200O4r

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

11/17/2003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-052, MWO No. 1200204580 (address)

(P.O. no., job no., etc.)

3. Work Performed by Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of Systemn System Number 064 SystemName:

Reactor Coolant System 5.(a)Applicable ConstructionCode and Class:

ASME B&PV Code Sect. Ill, 1968 Edition, Winter 1968 Add; Class A, CCases N-2, N-10.

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 EditIon

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oz Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Valve Dresser Industrial SN: BN-04373 N/A Unit One Pressurizer Safety 1977 Repalred/Repi Yes Valve Co.

Relief Valve aced Nozzle Dresser Industries 15988-GX SN: ACS N/A Nozzle, Maxflfow Relief Valve, 2 1996 Replacement Yes Inc.

96 1/2 In, Model 31739A, Dresser F/N 423170 IN, ASME SA-182 Gr.

F347 Relief Valve Dresser Industries 404679 SN: BM-N/A Valve, Consolidated Closed 2002 Replacement Yes Inc.

07953 Bonnet Maxiflow Safety; 2-112 In.

Model 31739A, only for RV 200 location.

Disc Dresser Industries 95597-GX SN: ACM N/A DIsc, Maxinfow Relief Valve, 2 1/2 1995 Replacement Yes Inc.

76 In, Model 31739A, Dresser P/N 1840404N, ASME SB-637 Gr. 688

7. Description of Work:

This plan was for the replacement of Unit-I Pressurizer Safety Valve, 1-RV-200.

8. Tests Conducted:

Hydrostatic:n Pneumatico Nominal Operating Pressure:

Inservicc E Leakage:E.

Functional:[]

Pressure:

2250 psi.

Test Temperature:

594 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

A Section Xl System Leakaae Test of the affected component was Performed duino the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: NIA Expiration Date: N/A iD

//

Charles H. Ballard Signed:

A, e

nEngineering Technician Date:

11/17/2003 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period to

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

7 Commissions: coa'x 4bg-:7 -'4) I f7D I Z /

Inspector's Signature National Board, State, and Endorsements Date:

.g

/

20 -o

inutra ValvesI Alexandria, Louisiana USA FORM N-2 OR NPT CERliFICATE HOLDERS' DATA' REPORT FOR IDEBIiCAL NUCLEAR PARTS AND APPUIRTENANCESX As Required by the Provisions of the ASME Code,Section III, DIv. 1 Not to Exceed One Day's Production Page 1 of 1 Dresser Industries, Inc., Dresser Valve & Controls Div. Industrial Valve Operations

1. Manufactured and certified by Intersection Hwv. 167 & 3225 Nbrth. Alexandria. LA 71309-1430 IName and Address of Certificate Holder)
2. Manufactured for Baltimore Gas & Electric P. 0. Box 1535 Baltimore, MD 21203-1E35 (Name and Address of Purchaser)
3. Location of Installation Baltimore Gas & Electric 1650 Caiverts Cliffs Parkway lusby, MD 206574702 (Name end Addreasl
4. Type OS417

- SA182 Gr. F347 76 KSI N/A 1996 (Drawing No.)

(Mat'l. Spec. No.1 (Tensile Strength)

(CRN)

(Year Built)

5. ASME Code,Section III Division 1:1968 Wrnter 1968 Article 9 (Cl. 11 NIA (Edition)

(Addenda)

(Class)

Code Case Noj

6. Fabricated In accordance with Const. Spec. (Div. 2 only) N/A Revision iN/A Date NiA

-l--J,_.ttSA(No.)

/.

11emarKs:

rI/P.

8. Norn. thickness tin.)

NIA MiUn. design thickness finj) N/A Dia. ID (ft.&in.L!N/ALength overall (ft.&In.)liNA S. When applicable, Certificate Holders' data reports are attached for each item of this report.

Part or Appurtenance National Board No.

Serial Number In Numerical Order 171 1191I (I A f117 MIt fo l r)_

Part or Appurtenance National Bloard No.

serial Number In Numerical Order 12 A) 5271 12R)

( 1 7 1 14 M )_

41 2 1 )_

(4 12 2 1 1 7 1 1 4 0 )

10.Design Pressure N/A psi Temp. N/A

  • F Hydro test pressure 4500 PSIG at temp. 'F

'Supplemental Information In form of lists, sketches or drawings may be used provided, 1 I size is 8 1K x 11, (2) Information In items 2 & 3 on this data report Is Included on each sheet, (3) sheet Is numbered and number of sheets is recorded at top of this form, and (4) each additional sheet shall be signed by the Certificate Holder and the ANIL

CERTIFICATE OF DESIGN Design specifications certified by N/A P.E.

NIA Rag. no.

N/A (when applicablo)

Design reports certified by N!/A P.E.

N/A Reg. no.

Wj A

CERTIFICATE. OF COMPLIANCE We certify that the statements made In this report are correct and that this (these)

Nozzles conform to the rules of construction of the ASME Code, Section il Division 1.

NPT Certificate of Authorization No.

N-2434 Expires May 20, 1998 Date l/

/9?

Name See Line 1 Signed /

?

(NPT Certificata Holder)

(authodzad representalva)

CERTIFICATE OF INSPECTION l, the undersigned, holding a valid commission by the National Board of Boiler and Pressure Vessel Inspector and the state or province of Louisiana and employed by The Hartford Steam Boiler ingspctlon & Insurance Co.,

of Hartford, CT, have inspected these Items described In this data report on

  • /Kf

. and state that to the best of my knowledge and believe, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section liI Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Impfled concerning the equipment described In this data report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or loss of any kind arising from or connected with this Inspection.

Date Signed Commissions (Authorized rispector)

MNat'l. Bd. (in. endorsement) astate or prov. and no.1

.A, r

A a

eadria LuwaI A Alexandria, Laulstana USA FORM N-2 OR NPT CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES" As Required by the Provisions of the ASME Code,Section III, Div. 1 Not to Exceed One Day's Production Page I of I Dresser Industries, Inc., Dresser Valve & Controls Div. Industrial Valve Operations

1. Manufactured and certified by Intersection Hwy. 167 & 3225 North, Alexandria. LA 71309-1430 (Name end Address of Certificate Holder)
2. Manufactured for Baltimore Gas & Electric P. 0. Box 1635 Baltimore, MD 21203-1535 (Name and Address of Purchaser)
3. Location of Installation Baltimore Gas & Electric 1650 Calverts Cliffs Parkway Lusby, MD 20657 (Name and Address)
4. Type OS417 S5637 Inconel X750 NtA NJA 1995 (Drawing No.)

IMat1. Spec. No.)

(Tensile Strength)

(CRN)

(Yeer Bunt)

5. ASME Code, Section ill:

1968 Winter 1968 A Article 9 NJA lEdition)

(Addenda)

(Class)

ICodo Case No.)

6. Fabricated In accordance with Const. Spec. (Div. 2 only)

N/A Revision NIA Date N/A Pa-

-.a(NoJ)

7. remarnas:

_ NM

8. Nom. thickness tin.)

NIA Min. design thickness (in.) N/A Dla. ID (ft.&in.). NIALength overall (ft.&in.) NlA

9. When applicable, Certificate Holders' data reports are attached for each Item of this report.

Part or Appurtenance National Board No.

Serial Number In Numerical Order III A4IM 71 MI} ArM7s 141 AthM 74 cm AeM 75 m7, (t9m

'in' El7 1141_

~

'_________*______I__

..7 Ev41 E,%l Part or Appurtenance National Board No.

Serial Number In Numerical Order Mul tam

'in},

t461

{141 1341 (IRM 1491 W41 1441 1468 M 5}

t4rm

!'47 ---

--I

.. ;U...

10.Design Pressure N/A psi Temp. N/A

  • F Hydro test pressure 4500 at temp. 'F

'Supplemental Information in form of lists, sketches or drawings may be used provided, (1) size is 8 Y x 1 1, (2) information In Items 2 & 3 on this data report Is Included on each sheet, (3) sheet Is numbered and number of sheets Is recorded at top of this form, and (4) each additional sheet shall be signed by the Certificate Holder and the ANI.

I CERTIFICATE OF DESIGN Design specifications certified by N/A P.E.

NIA Reg. no.

NLA (when appUcabla)

Design report' certified by NIA P.E.

N/A Rag. no.

N/A CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that these disc conform to the rules of construction of the ASME Code, Section IlIl.

NPT Certificate of Authorization No.

N-2434 Expires May 20. 1995 Date,/27LiL Name See line 1 Signed

'(NT Certificate Holdars (authorized rop.en CERTIFiCATE OF SHOP COMPLIANCE I, the undersigned, holding a valid commission by the National Board of BoIler and Pressure Vessel inspector and the state or province of Louisiana and employed by The Hartford Steam Boiler InoectonA Insurance Co.,

of Hartford, CT, have Inspected these Items described In this data report on

//'o

/IS

  • . and state that to the best of my knowledge and believe, the Certificate Holder has fabticated these parts or appurtenances in accordance with the ASME Code, Section lil. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied concerning the equipment described In this data report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date Signed d

,I?

Commissions ro.

/

AuthoIzed In-speotori (Nat'!. Bd. ((nol. endors amants) state or prov. and no.)

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

11/17/2003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-062, MWO No. 1200204580 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Summer 1971 Add; Class One (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:
Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Piping System Bechtel 2 1/2"CC-10-1007 N/A Pressurizer Piping to Safety 1975 Repaired/Rept No Relief Valve 1-RV-200 aced Nut Cardinal Industrial S7533-GX N/A Nut, Heavy Hex, I 1/8 In. X I TPI, 1992 Replacement No Products Inc.

ASME SA-194 Gr. 7 Rod Allied Nut & Bolt 18438 N/A Rod, Allthread, I 1/8 In. X 8 TPI, 1998 Replacement No Co. Inc.

ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the replacement of pressure retaining fastener materials on 1-RV-200 on the Inlet flange to the piping system 1#CCIO-1007.

8. Tests Conducted:

Hydrostatic:E PneumaticO Nominal Operating Pressure:

rIservice:E Leakage:f Functional:'El Pressure:

N/A psi.

Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RevalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Syrnbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

NIA

/1e I/Charles H. Ballard Signed:

EngineeringTechnician Date:

11/17/2003 Owner or ees Designee, Title Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period to

, and state to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: A~ ZY/3/

V,7#4 -

A4 /Z7(

/

Insnectoes Sigmature National Board, State, and Endorsements Date: /--

/200_

3

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI Calvert Cliffs Nuclear Power Plant, Inc.

1. Owner

, (name)

Date:

01124/2003 Sheet I of a.

1650 Calvert Cliffs Parkway; Lusby, MD 20657 (addmss)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One R&R No. 2002-1.060, MWO No. 1200204888 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

(P.O. no., job no., etc.)

3 WorkPefomedby:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (nWokamre) y.Authorization No.: NIA Exp Date:

A Section XI Class:

1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

One

4. Identification of System:

System Number 064 SystemName:

Reactor Coolant System

5. (a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Summer 1971 Add; Class One (b) Applicable Sect M Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, ol Stanmed Built Replacemere (YMs or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Tubing System Bechtel I

Tubing Consolidated Power Supply Tubing Nut bid Atlantic Instrumentatlon Inc Tubing Ferrule Mid Atlantic Instrumentation Inc Tubing Union Parker Hannifin Corp NIA 20439 Ht. 0442042 18402-GX Beat Code: TIH 18402-OX Beat Code: CEKU --

77567-GX Heat Code: CBTD NIA

  1. 11 Pressurizer Instrumentation N/A Tubing, 1m2 In. X.065 Wall, ASME BA213, Tp. 316 N/A Nut, Tabe, 1/2 In. Parker Hanuifln, P/N 8BZ4;S, ASTMIASME A/SA182 or A/SA479, Tp. 316 N/A Ferrule, Tube, 1m2 In. Parker Hanailln, PIN 8TZ-SS, ASTMJASME A/SA182 or A/SA479, Tp. 316 NIA Union, Tube, 3/4 In. X In2 "n4arker Hannlfin, PIN 12TZ-SS,ASTMWASME A/SAIU2 or AISA479, Tp. 316 1970 RepalrWRepl aced 1998

.Replacement 7

1997 Replacement 1997 Replacement 1 992 Rep latc emen t No No No No No

7. Description of Work:

I This plan was for the work and parts needed to replace tubing and fittings upstream of 1-HVRC-1180, a drain valve for instrument I-LT-1 1OX.

8. Tests Conducted:

Hydrostatic:fl PneumaticQ Pressure:

N/A psi.

Nominal Operating Pressure:

Inservice:C Leakagc: C Functional: Q Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-ll2 in. x I I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheetaof g.

FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Serfice NDE was performed in support of this activity.

Applicable Manufactuer's Data Reports to be Attached Certificate of Complance

_______cfn__

We certifyrthat the statements made in this report are correct and thatthis Roileaemrtc~onronnto the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A CertificateofAuthorizationNo.: N/A ExpirationDate:

N/A

°/ (7 0 o4D

/

Charles IL Ballard Signed:

Engineering Technician Date:

01/24/2003 OwnerorOwneesDesigneeitle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described inthis Owners Report during the period

//- /O 2

to 2-2/-

O3

.and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furtiermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or pmperty damage of a loss of any kind arising from or connected vt~ipc Commissions:

A14 7/7 Z-9P4-

,x/5 k l wr$Signature Nadonal Board, State, and Endorsements Date:

Z/-

200 &L

' -1 FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6/1512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-022a, MWO No. 1200205233 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

Two (address)

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control 5.(a) Applicable ConstructionCode and Class:

ASME Draft Code for Pumps & Valves,1968 Editlon, March 1970 Add; Class-2 (b) Applicable Sect Xl Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Conponents:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, o0 Stamped Componet Manufacturer Serial Number Board No.

- Identification Built Replacemen (Yes or No)

Valve Velan Engineering I-CKVCVC-165 N/A

  1. llCbargIng Pump Discharge 1975 Repalred/Repl Yes Co.

Check Valve aced Check Valve Enertech Inc.

408934 SN: 11273 N/A Valve, Nozzle Check, 2 In., 1500 2002 Replacement Yes lb., Large Groove connections, Enertech, Tp. KRV (Mark #

212M3N)

7. Description of Work:

Thus plan was for the replacement of 1-CKVCVC-165, #1 ICharging Pump Discharge Check Valve.

8. Tests Conducted:

Hydrostatic:]

Pneumatic:

Nominal Operating Pressure:

Inservice: O Leakage: F Functional:

Pressure:

2400 psi.

Test Temperature:

115 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakage Test of the affected component was performed durina the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Reolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/15/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 7-aY

~

-03 to G -mO Y

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

,TVJ A)1Z4 ZIS PEEL 7-F*FS Commissions: /V 15 I

. A) II/A7/

A. //

-Anr4 NIoal Bo ard,

/w

//Srse

.TIn~ectoi't 1.ionature National Board, State, and Endorsements Date:

44 -,IG60

FORM NPV-I CERTIFICATE fOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code.Section III, Division I

1. Manufactured and certified by Enertech, A Div. of CurUss-Wright Flow Cbntrol Corp., 2950 Blirh St., Brea, CA 92821 (name and address of N Certificate Holder)
2. Manufactured for Calvert Cliffs Nuclear Power Plant, PO Box 17323, Baltimore, MD 21297-1323 (name and address of Purchaser)
3. Location ot instalation Calvert Cliffs nuclear Power Plant; 1650 Calvert Clffs Parkway,-Lusby, MD 20657 (n~ame and address)
4. Model No., Series No., or Type KRV Drawing MD20990 Rev A

CaRN None

6. ASME Code, Section rtl Division 1:

1995 ba dt 1

None (edition) laddenda data)

(class) lCode Case no.)

6. Pump or valve Nozzle Check Valve Nominal Inlet slze-2 Outlet size 2

7nd oin.)

7. Material:

Body SA-479 Type 31 6 66e N/A________________

(a)

Cert.

Holder's Serial No.

1 1256 11257 11258 11259 11260 11261 11262 11263 11264 11265 11266 11267 11268 11269 11270 11271 11272 11273 lb)

Nat'l Board No.

None.

None None None None None None None None None None None None None None None None None IC)

Body Serial No.

KNG-001 KNG-002 KNG-003 KNG-004 KNG-005 KNG-006 KNG-007 KNG-008 KNG-009 KNG-010 KNG-011 KNG-012 KNG-013 KNG-014 KNG-015 KNG-016 KNG-017 KNG-018 (d)

Bonnet Serial No.

None None None None None None None None None None None None None None None None None None (el Disx Serial No.

KNH-001 KNH-002 KNH-003 KNH-004 KNH-005 KNH-006 KNH-007 KNH-008 KNH.009 KNH-010 KNH-01 1 KNH-012 KNH-013 KNH-014 KNH-015 KNH-016 KNH-017 KNH-018

  • Supplemental kIformasion In form of lists, sketches. br drawings may be used provided II) size is81 x 11, (2) hinformetion iM Items 1 through 4 on this Data Report Is Included on each sheet (31 each sheet is numbered end the number ot sheets Is recorded at the top of this forn.

112188)

This form (E00037) may be obtained from the Order Dept.. ASME, 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300.

&9PRINT M3

I AM NPV-1 (Back -

Pg. 2 of 2..)

..11256 thru Certificate Holder's Serial No.

11273

8. Design conditions 2800 psi 250 e or valve pressure 1500 11

__ps___ralvpesur class

()

(pressure)

(temperaturel

9. Cold working pressure 3600 psi at I 0°F
10. Hydrostatic test 5400 psi. Disk differential test pressure N/A psi
11. Remarks: Oty. 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN Design Specification certified by JohnR.Sponsel, I P.E. State MD Rag.

17308 DesignReport certifiedby Ira J, Silverman p.A. State C

eg. no.

23241 CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Cods, Section ill, Division 1.

ao i'i-Z1!5.

is __a____

As NPLertrincae 01 Autnorizalon No.

Date _____

_0__3 Expato 1

d s1 1/Ut Signed a

(authoriecd represuntatva)

Nsame Enertd Oiv. d CuLs.Wrd Fow Convol Corp.

IN Certificate Holder)

CERTIFICATE OF INSPECTION 1, the undersigned. holding a valid commission issued by the Nationsl Board of Boler and Pressure Vessel Inspectors and the State or Province of Califoia and employed byHSBCT of Connecticut have inspected the pump, or valve, described in this Data Report on

/i /

, and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, In accordance with the ASME Code, Section Ill, Division 1.

By signing this certificate, neither the Inspector nor Nis employer makes any warranty, expressed or Implied, concerning the component described in this Data Report; Furthermore, neither the Inspector not his employer shall be liable ln any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date -

£6'0S Signed

4.

Com rnmisaions eav1go ;

04 %

A/

(Authorized Inspector)

INafl. Bd. lncl. endorsements) and state or prov. and no.]

(I) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner.

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

6/1512004 Sheet I of 2-.

1650 Calvert Cliffs Parkway; Lusby, MD 20657

2. Plant:

(address)

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-022b, MWO No. 1200205233 (address)

3. WorkPerformedby-Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: NIA Authorization No.: N/A Exp Date: N/A Section Xl Class:

Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME Repaired,.

Code Year Replaced. oI Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Piping System Bechtel 2" CC-7-1001 N/A

  1. 11 Charging Pump Discharge Piping Pipe Insert Reducer Tee Nut Ailthread Rod DuBose National Energy Services Inc.

DuBose National Energy Services Inc.'

DuBose National Energy Services Inc.

Mackson Inc.

Mackson Inc.

400298 Ht#: 8324H 54906-GX Heat Code: DVE 54906-GX Heat Code: BV 400066 Heat Code:

JIX 410155 t#: S20751 409374 Ht. Code:

BEZ N/A Pipe, 2 In., Sch. 160, ASME SA-376, Tp. 316 NIA Reducer, Insert, 2 In. X 3/4 In.,

6000 lb, Socketweld, ASME SA-182, Gr. F316 N/A Tee, 2 In, 6000 lb., Socket Weld, ASME SA-IS2, Gr. F316 N/A Nut, Heavy Rex, 7/1 In. X 9 TPI, ASME SA-194 Gr. 2H NIA Rod, Allthread, 7/8 In. X9 TPI, ASME SA-193 Gr. B7 N/A Flange, 2 In., 1500 lb., Large Tongue, Socketweld, ASME SA-182, Gr. F316 1975 Repalred/Repi aced 2000 Replacement 1992 Replacement 1992 Replacement 2000 Replacement 2003 Replacement 2003 Replacement No No No No No No No Flange DuBose National Energy Services Inc.

7. Description of Work:

This plan was for the work, piping, fittings, hanger supports and fasteners needed to support the replacement of 1-CKVCVC-165 and IHVCVC-166, #11 Reactor Coolant Charging Pump discharge Check Valve and Isolation valve.

8. Tests Conducted:

Hydrostatic:[]

Pneumatico Pressure:

2400 psi.

Nominal Operating Pressure:

Inservice: 6 Leakage: l Functional: El Test Temperature:

1 1 5 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 1 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is

SheetQof 2-FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Inservice Test of the affected component was Perforrned during the system

,nneditnnc lichmte in comi-inn 8. nf this nannrt CodefCaseQ~ Nt11-2l-wasQ invotkned tam 3isfv Sat~ion Yl we.

~

v.

vex U s,

v<

ou Eut

-v-~

e..

,- t..

1v -.-

s v

-,9.-v I I.

reauired Dressure tests. Addtional Section III Examinations were Derformed (as applicable) to satisfy Code Case N-416-2 and Re-q.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A ReoalrlReolacement Charles H. Ballard Engineering Technician Signed:

Date:

6/15/2004 Owner or Ownei's D~sijiiee Title '

I Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod 7-OY-o3 to 6-/0O1

. and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section M.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bosIhJ AJO.-2USd Pt

-7Em -I-<

Inspecto's Signature Date:

6 -/6 200-Y Commissions:

AJ813 9t;

, /

D i/;7/, A4IV National Board, State, and Endorsements

. i v -

-'4 FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date 611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-022c, MWO No. 1200205233 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

Two (address)

4. Identification of Systern SystemNumber 041 SystemName:

Chemical Volume Control

5. (a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, ot Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Valve Velan Engineering 1-HVCVC-166 N/A

  1. 11 Charging Pump Discharge 1975 Repaired/Repi Yes Co.

IsolatIon Valve aced Gate Valve Framatome ANP 400425 SN: 001028-1 N/A Valve, Gate, 2 In. 1690 lb.; ASME 2001 Replacement Yes Inc.

SA-132 Gr. F316

7. Description of Work:

This plan was for the replacement of 1-HVCVC-166, #11 Charging Pump Discharge Isolation Valve.

8. Tests Conducted:

Hydrostatic:[]

PneumaticCl Nominal Operating Pressure:

Inservice: El Leakage: W Functional: 1 Pressure:

2400 psi.

Test Temperature:

115 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl Svstem Leakaae Test of the affected component was performed during the system cnnditions listed in section 8. of this report.

Code Case N-416-2 was invoked to satisfy Section XI reauired pressure tests. Addtional Section III Examinations were Derformed (as applicable) to satisfy Code Case N416-2 and Reci.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamnp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A RepalrlReplacement Signed:

A4740 xYi' Charles H. Ballard Engineering Technician Date:

6/15/2004 Owner or Own sibnee, Titedi Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 7 -A -o 3 to C -/p ' -

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with the requirements of the ASME Code, Section Xa.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his -

employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

ach4-e A. stH4-P/1124 r/azw Atiz-

D i+AJl &77-&2S _

Commuissions: flJr6 9 {5 1, Ate //'7/, A///1 Inspector's Signature Date:

6 & /6 200 N t n B 1o r-7dA

, State a E

National Board, State, and Endorsemnents

£ DATA PACKAGE NO.

001028 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES

  • As Required by the Provisions of the ASME Code,Section II, Division 1 Pg. 1 of -. 2.
1. Manufactured and certified by VELAN iNC. 2125 WNRD AVE.MONTREAL.OUEEBC CANADA g4KlT6 (ncame and address of N Certillcate Holder)
2. Wanufactured for FRAMTO1ME TECOLOGIES 3315-A OLD ZOItEST RD.LYXCHB1TRG.VA.IJSA 24501 (name and address of purchaser)
3. Location of installion

-IA (name and address)

4.

Model No.,

Series No.,

or Type: GAT Drawing PI-76800-N22 Rev E

CRN_./A

5.

ASME Code,Section II, Division 1:

1989

.OQ.

I (edition)

(addenda date)

(class)

(Code Case no.)

6. Pump or valve VALVE Nominal inlet size 2._.2Outlet size 2

(In.)

-('n.)

7.

Material: Body, SA-182.F316 BonnetSA-182.7316 Disk SA-351.CP8M Bolting SA-194.8M SA-564,630H1100 (a)

Cert.

'Holder I s Serial No.

001028-1 a001028-2 001028-3 C01028-4 001028-5 OC1028-6 uu======

(b)

Nat'l Board NO.

N/A

_I (c)

Body Serial No.

. R/C:CX CAK CAX CAK CUX

=N v

(d)

Bonat Serial NO.

!c:

ZA YZA YZA FZA FZA

_i (e)

Disk Serial No.

E/C: 750 I 75G 750 75G 750 1 ?

_m

.P Supplemental Information hI form of rists, sketches, or drawings may be used provi'ded (1) slfe Is 1/2 x ll,(2) Information In Items 1 through 4on is Data Report Is Included on each sheet, (3) each shest Is numbered and the number of sheets Is recorded at the top of this form.

(12/38)

Ths form (E00037) may be obtained trom the Order Dept, ASME, 22 LAW DRIVE< BOX 2300 Fatrield. NJ 07007-2300.

.t@ ¢t w

PAGE 3

w OFsA

FORM NPV-1 (Back -

Pg. 2' 6f 2

)

Certificate [older's Serial No.

001028

8. Design conditions 4055 psi 100
  • F or valve pressure class 1690 (12)

(pressure)

(temerature)

9. Cold working pressure 4055 psi at 100F7
10. Hydrostatic test 6350 psi. Disk differential test pressure 4650 psi Remarks:

MATSERIALS MEET AS= SECTION II EDITION: 1989 ADDENDA:

NONE C:RTIF}CATI OF CONTLXANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construct'on of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2797-1 3xp Date OCT I A XOI1_

Name VELAN NC.

Signed (N Certificate Holder) uhorind repr tie)

CERTIFICATZ OF INSPECTION I,

the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of OUBBSC and employed by REGIZ DU BATIMENT c

a I

OUEBEC /

have inspected the pump, or valve, described in this Data Report on U*t4.O4 / lO' O, and state that to the best of my knowLedge and belief, the Certificate Holder has.onstructed *this pump, or valve, in accordance with the AS1H Code, Section I1, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warrenty, expressed or implied, concerning the component described in this Data Report. Furthermor.,

neither the inspector nor his employer shall be liable in any mamaar for any personal injury or propert, damage or a loss of any kind arising from or -connected with this inspection.

NZL__

J. MARCHAND Q

871 Date signed o=1issions 0t3BEC QC #

/

~t d Inspector) 3 (Nat'L Bd (f~tciE u

D QU t

.4

(

/ 1/

stre or prov. andano.)

,,

(1) For manually operated valves only.

. arri t

.7 -..

rP~~n$

-L 4.

-SL

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASMt Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

6/1612004 Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657

2. Plant:

(address)

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-052a, MWO No. 1200205235 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no-,job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

Two

4. Identification of System:

System Number 041 SystemName:

Chemical Volume Control 5.(a)ApplicableConstructionCodeandClass:

ASME Draft Code forPumps & Valves, 1968 Edition, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Velan Engineering Co.

SN: 8370 Check Valve Enertech Inc.

408934 SN: 11271 N/A

  1. 13 Charging Pump Discharge Check Valve N/A Valve, Nozzle Check, 2 In., 1500 lb, Large Groove connections, Enertech, Tp. KRV (Mark#

212M3N) 1975 Repaired/Repi aced 2002 Replacement Yes Yes

7. Description of Work:

This plan was for the replacement of 1-CKVCVC-177, #13Charging Pump Discharge Check Valve.

8. Tests Conducted:

Hydrostatic:E Pneumatics Pressure:

2352 psi.

Nominal Operating Pressure:

Inservice: E Leakage: E Functional: 1-Test Temperature:

17 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 1 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2f M2

.5_ h FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/16/2004 Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9 - AD-03 to

( -/0 - OY

. and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

>7O"J AKJI-&S Pew Commissions: A113 9&3)

/ 1//7/1 14//1 A

,7

/

at AD o

A Insoector's Signature National Board, State, and Endorsements Date:

(O '/

200 9

i.

I FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division I Pg. 1 of 2

1. Manufactured and certified by Enertech, A Div. of Curtiss-Wright Flow Control Corp., 2950 Birch St., Brea, CA 92821 Iname end addresi of N Cirtiflcate Holder)
2. Manufactured for Calvert Cliffs Nuclear Power Plant, PO Box 17323, Baltimore, MD 21297-1323 (name and address of Purchaser)
3. Location of InstallatLon Calvert Cliffs nuclear Power Plant; 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (name and address)
4. Model No.. Series No., or Type KRV Drawing MD20990 Rev.

A CRN None

6. ASME Code, Section-iP, Division 1:

1995 1996 1

NQne iedition) laddenda date)

(class)

(Code Case no.)

6. Pump or valve Nozzle Check Valve Nominal Inlet aize 2

Outlet size 2

On.)

oin.)

7.Material:

Body SA49Tye3 6rionet N/ADisk SA-479Tye316 Bolting NA la)

Cort.

Holder's Serial No.

11256 11257 11258 11259 11260 11261 11262 11263 11264 11265 11266 11267 11268 11269 11270 11271 11272 11273 (b)

Nat'l Board No.

None None None None None None None None None None None None None None None None None None Ic)

Body Serial No.

KNG-001 KNG-002 KNG-003 KNG-004 KNG-005 KNG-006 KNG-007 KNG-008 KNG-009 KNG-010 KNG-011 KNG-012 KNG-013 KNG-014 KNG-01 5

  • KNG016 KNG-41 7 KNG-018 (d)

Bonnet Serial No.

None None None None None None None None None None None None None None None None None None (el Disk Serial No.

KNH-001 KNH-002 KNH-003 KNH-004 KNH-005 KNH-006 KNH-007 KNH-008 KNH-009 KNH-010 KNH-011 KNH-012 KNH-013 KNH-014 iKNH-015 KNH-016 KNH-017 KNH-018

  • Supplemental Information In form of Uts. sketches. br drawings may be used provided (1 size Is 8% x 11, W2 Information In Items 1 through 4 on this Data Report is Included on each sheet. 131 each sheet Is numbered and the number ot sheets Is recorded at the top of this torn.

(IV88)

This form 11200037) may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300. Fairfield, NJ 07007.2300.

IMPRINT as

.M NPV-t 1Back-.Pg. 2 of 2

l 1 1256 thru Certificate Holder's Serial No.

11273

8. Design conditions 2800 Psi 250 F or valve pressure dass 1500 (1)

Ipressure)

Itemperaturel

9. Cold working pressure 3600 psi at 1001F
10. Hydrostatic test 5400 psi. Disk differential test prassure N/A 1 i. Remarks: Oty. 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN Design Specification certified by John R. Sponsel, II P.E. State MD Reg. no.

17308 Design Report certified by Ira J. Silverman P.E. State CA Reg. no.

23241 CERTIFICATE OF COMPUANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2826 Exp>,

10/11/05 Date a/4/3

-Name Enenled AOiv. Curss-Wrht sFbWCa orCO p.

IN Certificate Holder)

Signed I

6 A

T (authorized represuntatlvel CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California and HSB CT the tateor Povine ofandemployed by of Connecticut have inspected the pump, or valve, described in this Data Report on l - if.

  • and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, In accordance with the ASME Code, Section Ill, Division 1.

By signing this certIficate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date 1' bt- @0Signed Ag PŽ. P W icosmissions

'A/9'2 P

(Authorized Inspector)

INati. 8d. (lncL endorsernents) and stme or prov. and no.1 (1) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owier:

Calvert Cliffs Nuclear Power Plant, Inc.

Date 611612004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 0-(address)

2. Pl Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-052b, MWO No. 1200205235 (address)

(P.O. no., job no., etc.)

3. WorkPerformedby:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Starnp: N (name)

AuthorizationNo.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section X Class:

Two (address)

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control 5.(a)ApplicableConstructionCodeandClass:

ASME B31.7 1969 Editlon, Sum.1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Cornponents Repaired or Replaced and Replacement Components:

Name of Cornponet Piping System Pipe Insert Reducer Tee Nut Allthread Rod Flange Coupling Pipe Strap Name of Manufacturer Bechtel DuBose National Energy Services Inc.

Energy & Process Corporation DuBose National Energy Services Inc.

Mackton Inc.

Mackson Inc.

DuBose National Energy Services Inc.

Ladish Co.

Anvil International Inc. Grlnnell Supports Manufacturers Serial Number 2" CC-7-1003 400298 Ht.#: 8324H 411138 Heat Code:

EM6S S4906-GX Heat Code: BV 408227 Ht.#: S44018 410155 Ht#: S20751 409374 Ht. Code:

EHI F-8588 Heat Code:

D6MG H 34757 Lot#: 17925 NB Bo ational Other ard No.

Identification NtA

  1. 13 Charging Pump Discharge Piping N/A Pipe, 2 In., Sch. 160, ASME SA-376, Tp. 316 N/A Reducer, Insert, 2 In. X 1 In, 6000 lb., Socketweld, ASME SA-182, Gr. F316.

N/A Tee,2 1In, 6000 lb., Socket Weld, ASME SA-182, Gr. F316 N/A Nut, Heavy Hex, 7/8 in. X 9 TPI, ASME 6A-194 Gr. 2H NIA Rod, Allthread, 7/M In. X 9 TPI, ASME SA-193 Gr. B7 NIA Flange, 2 In, 1500 lb., Large Tongue, Socketweld, ASME SA-182, Gr. F316 N/A Coupling, 2 In., 6000 lb., ASTM A-182, Gr. F316 N/A Strap, Pipe Guide, 2 In., for PG-44, BGEDRWG FSK-MP-0571SH 0005 & 6, Item #2 ASME

Repaired, Code Year Replaced, ox Stamped Built Replacemen (Yes or No) 1975 Repaired/Repl No aced 2000 Replacement No 2003 Replacement 1992 Replacement 2002 2003 2003 1973 1999 Replacement Replacement Replacement Replacement Replacement No No No No No No No
7. Description of Work:

This plan was for the work, piping, fittings, hanger supports and fasteners needed to support the replacement of 1-CKVCVC-177 and 1HVCVC-178, #13 Reactor Coolant Charging Pump discharge Check Valve and Isolation valve.

Sheet 2 of 2 FORM NiS-2 (Back)

8. TestsConducted:

Hydrostatic:O Pneumatics Nominal Operating Pressure:

Inservice:

Leakage:Eo Functional:O Pressure:

2352 psi.

Test Temperature:

1 17 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of {his form.

9. Remarks:

A Section Xl System Leakage Test of the affected component was Performed during the system conditions listed in section 8. of this report.

Code Case N-416-2 was invoked to satisfy Section Xl required Pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Reolacement conforms to the rules of the ASME Code, Section XM.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

Engineering Technician Date:

.6/16/2004 Owner or awesDsgne il Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9

-AN- 0 5 to 6 -/&) -

/

and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or

-- c-rined-CStlhisi espection.

-I

.7-TL)4o-J AMILX Pe 7Z/'1 Commissions: l'S W3/,AI,9//7/ 1 A4iJ//

Insoector's Signature National Board, State, and Endorsements Date: 6 - / 7 -

200 if

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6117/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-052c, MWO No. 1200205235 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

ype Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

Two (address)

4. Identification of System:

System Number 041 SystemName:

Chemical Volume Control

5. (a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves,1968 Edition, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Valve Velan Engineering 1-HVCVC-178 N/A

  1. 13 Charging Pump Discharge 1975 Repalred/Repi No Co.

Isolation Valve aced Gate Valve Vendor. BWNS 70390LNP SN:

N/A Valve, Gate, 2 In. 1690 lb.; ASME 1994 Replacement Yes Nuclear 941005-1 SA-182 Gr. F316 Mfgr: Velan Engrg. Co.

7. Description of Work:

This plan was for the replacement of 1 -HVCVC-178, #13Charging Pump Discharge Isolation Valve.

& TestsConducted:-- -Hydrostatic:E]-- Pneumaticfl -NominalOperatingPressure-

-- Inservice:--Leakage:

--Functional:

Pressure:

2352 psi.

Test Temperature:

117 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet2of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakaae Test of the affected comoonent was cerformed durina the system conditions listed in section 8. of this report.

Code Case N-416-2 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

Repair/Replacement Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Signed:

0 Charles H. Ballard Engineering Technician Date

6/17/2004 Owneror Owner's Designee,Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period

' X;L-c3 to (V /0 - 1V7, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Do)

AJAfi) A - S94-7'),4 iFtKL

,(l/Z sow Womits Pk' iff Inspector's Signature Date:

6_-_/_7 200-S Commissions: /JIq'3/,

,qO 1/7/ 44V//

a io77 l

/

oa0 Sae ad National Board, State, and Endorsements

  • e AR\\\\toS FORM NPVY 1CERTIFIC.

- HOLDERS' DATA REPORT FOR NUCLL.

PUMPS OR VALVES*

As Required b,

.e Provisions of the ASME Code. Sectio(

Division 1 Pg. 1 of

1. Manufactured and certified by It.&

\\

'\\Y&

NQ

\\i\\,

(name and address of N Certificate Holderl

2. Manufactured for Lvtii9& SRXN\\_O fi_

Ename and address of Purchaser)

3. Location of Installation (name-VW a ddress)
4. Model No., Series No., or Type GF,.

Drawing\\ '.

Rev.

6 CR

5. ASME Code. Section 111.

Division 1:

\\°!°.4 C

lditiont (addenda datel (class)

Coda Cse no.)

6. Pump or valve o Nominal inlet size Outlet size v
7. Materbl:

Body Bonnet Dkk Bi6XqC Bolting W

la)

(1b IC)

Id; (a)

Coet.

Nat'I Body 8onnet Disk Holders Board Serial senra 4.,i Serial Serial No.

No.

No.

No -

No.

9i\\ObSW

\\

tbW t

As-etll.%

i

\\

B~t -?

. ~ ~ ~

~

~

~

~

~

~

-V CC S:

C.S f,

41\\

  • Supplemental informraon in form of Hats. skitcas, or drawvngs may be used provided 111 ize s 8 X 1 on tis Dot Rport Is Included on each sheet. 13) each sheet Is numbered and the number ol shaots Is reco, 112188)

This form (E00037) may be obtained from the Order Dept.. ASME. 22 Law Drive

1. (21 information In items 1 through 4 8

rded at the top of this form.

B, ox 2300. Farfield. NJ 07007-2300.

[ PA E

PPF~

ORM NPV-1 (Back -

Pg. 2 of Certificate Holder's Serial No. -M M

B. Design conditions ~AQ 1&

psi aF or valve pressur, class Coeneasuraie S. Cold working pressure

- ~A psi at wo00F IO. Hydrostatic test (aii 1lso... psi.

Disk differential test pressure Wa^psi 1 1. Remarks: Anl~%

U SY\\

ai A

X.SS~

I CERTIFICATION OF DESIGN Design Specification certified by

-'& NJ.

pi.EStateDO

'e.n.MQ 1E Design Report catfe by -

S 4ak\\"%

CERTIFICATE OP COMPLIANCE We certify that the statements made in this report are correct and tht this pump at valve conforms to the rules for construction of the ASME Cods, Section Iii, Division 1.

A kpL w

N Certificate of Authorization No.

Expires Os A '

Dat amNin

\\'inCo Signed IN Cactifleate Hodder lauthoriad reprd~ntative)

CERTIFICATE OF INSPECTION I. the undersigned. holding a valid conjnission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or ifpvince of and employed by of have inspected the pump, or yaive, described in this Data Report on

-q 41-/

g, and state that to the best of my knowledge and belief, the Certificate Holder hies con-structed tWs pump, or valve, in accordance with the ASME Code, Section Ill, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described In this Data Report. Furthermore, neither the inspector not his employer shall be liable in any maniner for anty personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 2Ž4~.Signed

/'rommissions (Qe,

/ lAuthodedzs Intolator)

Naili. 0d.111vAt. endorsewnantsl and state or praw. and no.1 (II For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-077, MWO No. 1200205240 (address)

(P.O. no., job no., etc.)

3. Work Performed by Calvert Cliffs Nuclear Power Plant Dept.

Tpe Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a)ApplicableConstructionCodeandClass:

ASME B31.7 1969 Edltion, Sum.1971 Add; Class 1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Pipe Support Bechtel 2 1/2"CC-10-1003-H3 N/A

  1. 11 Pressurizer Pipe Support to 1-1975 Repalred/Repl No ERV.402 aced Spring Can Anvil International 411825 PN:

N/A Support, Constant, Anvil Figure 2004 Replacement No Inc. Grinnell 80VB014-NB SO-V, Size 14, Type B, with Travel Supports Stop, Load - 620 lbs.

7. Description of Work:

This plan was for the replacement of the Spring Can on pipe line 2 1/2"CC-10-1003, Pressurizer Piping to Electric Relief Valve 1-ERV-402, support number H3.

8. Tests Conducted:

Hydrostatic:[

PneumaticCl Nominal Operating Pressure:

Inservice: E Leakage: M Functional:

Pressure:

N/A psi.

Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-3 Visual Examination of the affected component suDDort was Derformed Drior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this ReaalrlReolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A AD S A t,/4J Charles H.

Ballard Signed:

Engineering Technician Date:

6/15/2004 Owner or Ok~ers-Des-ignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthis Owner's Reportduringtheperiod 39-7-a Y to 6 -3 09Y

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section MI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bDo&t-A.sn4f/o;"

f 2..

o Commissions: A) 8 9 T 3 All /M 7/41 1/

se tSn Nata B79o/ tte ad os Inspector's Signature National Board, State, and Endorsemnents Date: 6 - A 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

611412004 Sheet 1 of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657

2. Plant:

(address)

Calvert Cliffs Nuclear Power Plant (name)

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-078, MWO No. 1200205247 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section X1 Class:

One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System:

SystemrNumnber 064 System Name:

Reactor Coolant System S.(a) Applicable Construction Code and Class:

ASME 631.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Comnponet Name of Manufacturer Manufacturers Serial Number National Board No.

Other Identification Pipe Support Bechtel 2 1/2"CC-10-1004-H3 N/A

  1. 11 Pressurizer Pipe Support to 1-1975 ERV-404 Repalred/Repl aced No Spring Can Anvil International Inc. Grlnnell Supports 411825 PN:

SIHCO15-NB N/A Support, Constant, Anvil Figure 2004 Replacement 81-H-SIze 15, Type C, with Trave Stop, Load - 725 lbs, No

7. Description of Work:

This plan was for the replacement of the Spring Can on pipe line 2 1/2"CC-10-1004, Pressurizer Piping to Electric Relief Valve 1-ERV-404, support number H3.

8. Tests Conducted:

Hydrostatic:[J Pneumatico Pressure:

N/A psi.

Nominal Operating Pressure:

Inservice: E Leakage: E Functional: 0 Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-3 Visual Examination of the affected component supp~ort was Derformed Porior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Repiacement conforms to the rules of the ASME Code, Section X1.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

.ignee, Tf Engineering Technician Date:

6/14/2004 Owner or Owneiresignee le Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 3 -/ 7 0 3" to 60 /, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with inspection.

Aot. az7f)1J AJ7W Z/S fA)Z 7~Z6-t

>z- /i--LOY-Commissions:

MJ

?83/.

MO //7/.

/X//

V,6l /I77cf WV //3'S National Board, State, and Endorsements Date:

4 _/,y/

4r-v.oo 0e

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

611612004 Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Calvert Cliffs Nuclear Power Plant (name)

2. Plant:

Unit:

One 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-023a, MWO No. 1200205332 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.:

N/A Exp Date: N/A Section XI Class:

1650 Calvert Cliffs Parkway, Lusby, MD 20657 One (address)

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class`1-(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, Oz Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification 1975 Repaired/RepI Valve Velan Enginnering Co.

SN: 155 Gate Valve Flowserve Corporation 405820 SN: E506T-1-1 NIA Pressurizer Isolation Block Valve for I-ERV-402 NIA Valve, Gate, 2 1/2 In., 1703 lb.,

Sch. 160 Buttwelded, Flowserve P/N W01-25821, ASME SA-351 Gr. CF8M 1975 Repaired/Repl aced 2002 Replacement Yes Yes

7. Description of Work:

This plan was for the replacement of 1-MOV-403, #11 Pressurizer Isolation Block Valve for 1-ERV-402.

8. Tests Conducted:

Hydrostatic:r PneumaticO Pressure:

2260 psi.

Nominal Operating Pressure:

Inservice: E Leakage: i-Functional: a Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 a.2,z 0FORM NIS-2 (Back)

9.

narks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

A Section XI Surface Examination of the affected component was performed to satisv Section XI Pre-Service Requirements.

Code Case N-416-2 was invoked to satisfy Section Xl required pressure tests. Addtlonal Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

4 W9 9

Engineering Technician Date:

6/16/2004 Owner or Owners Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period /2 - A to

-.;2) -o*'

, and state to the best of my knowledge and belief; the Owner has performedexammations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

D0-JA*-t0 A SNA-ib^4 1-v-L 4R1 p.

Zroj" AIDDDS,

p Amp Commissions:

1 6 9&3/

1 AD //7/ X441//

IV J5 1A77 51 Af O /,'5..

Ins~netnr's Sirntum National Board, State, and Endorsements Date: & /7 7 2000

?<,-

0, FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the.Provlslons of the ASME Code; Section Iil, Division 1 Pg. 1 of 2 j

1. Manufactured and certified by Flowserve Corporation, 701 First Steeti Williamsport, PA 17701 Iname and address of N Certificate Holder)
2. Manufactured for Constellation Nuclear, P.O. Box 1609, Lusby, MD 20657

[name and address of Purchaser)

3. Location ot installation CCNPP, 165Q Calvert Cliffs Parkway, Lusby, MD 20657 (name and address)
4. Model No., Series No., or Type D.D. Gate Drawing W0125821 Rev.

A CRN NIA

'S. ASME Code, Section 111. Division 1:

1995 1996 I

N/A (edition)

(addenda date) cl(ssi (Code Case no.)

e. Pump or valve' Valve Nominal Inlet size 2 1/2" Outlet size 2 l1l" SA35l-CF8M SA351-CF8M Disk SA479-316 Bolt,',

Studs: SA453-660B 7.Material:

Body Bonnet Dolting (a)

Cart.

Holder's Serial No.

E506T-1-1 E506T-1-2 E506T-1-3 E506T-14 (bl Nat'l Board No.

N/A N/A

  • N/A NYA M

ic)

(d)

Body Bonnet Serial Serial No.

No.

'RI5 R21 R16 R19 R17 R20 R18 R22 Nuts: SA194-8M (e)

Disk Serial No.

6 and 19 5 and 18 7and20 8 and 21 '

.O ff Suppiemental informatIon in form of lists. sketches, or drawings may be used provided (1) aIze is 8 if, x II, (21 Information Initerns 1 through 4

'Supple montal Inforumationl In form of lists, sketches, or drawings may be used providedII size Is1 S K X 11l, 12) Informaton WIntern I through 4 on this Oata Report is Included on each sheet. (31 each shast Is numbered and the number of sheets Is recorded at the top of this form.

Ii2t8di This form (!000371 may be obtained fron the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ07007-2300.

REPRJNTSU93

FORM NPVY1 (Back -

Pg. 2 of 2..

CertificatelHoIlder'i SrialNo.

E506T1-1 thru 4 S. Design conditions 2485 psr 675 eF or valve pressure class 1703 (pressure)

(temperature)

9. Cold workingpressure 4087 psi at 100WF
10. Hydrostatic test

-61 pstL Disk differenttal test pressura 4500 psi

11. Re k: Maiterial: Bonnet Stads: (30) Trace Code E621 (2) Trace Code B719 Bonnet Nuts: (23) Trace Code TSK (9) Trace Code A288 I

CSRTIFICATION OF DESIGN Design Specification certified by John EL Spowel P.E. State MD Reg. no.

17308 Design Report certified by Ronald S. Farreff P.E. State PA Fleg. no. PE-0352 16-E CERTIFICATE OF COMPUANCE We certify that the statements made In this report are correct and that this pump or valve conforms to'the rules for construcifon of the ASME Code, Section Ili, Division 1.

N Csrtifica o ot Authortzatlon No.

N712 a

Flowserve Cotporation IN Certificate Holderl uthorized rs$senthval CERTIFICATE OF INSPECTiON I.

i the undersigned, holding a valid commission Issued by the National Board of 3oller and Pressuri Vessel Inspectors and the Statu 6MVIM of Pennsvlvania and employed by One Beacon America Insurance at Boston. Mass.

have Inspected the pump, or valve, described In this Data Report on I-/57 O0--J 3.

  • and state that to the beat of my knowledge and belief, the Certificate Holder has cont structed this pump, or valve, In accordance with the ASME Codas Section ill, Division 1.

By signind this cetficate, neither the Inspector nor his employer makes any warranty. expressed or Im 1fed con component described In this Data Report. Furthermore, neither the Inspector nor his eamployer ihal be liable in any er any personal Injury or proper a

r at Itany kind arising from or connected with this Inspection.

Date 43C Slgne

'~

mmrbasona Pennsylvania 2392 9

Cha~vrellt2t 0

INat'l. sd. fInd. endorsammntsi and stUs or prov. and no.J (11 For manually eperatid valves only..

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Calvert Cliffs Nuclear Power Plant, Inc.

1. Owner:

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

Date:

611612004 Sheet I of 2

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-023b, MWO No. 1200205332 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

One

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System

5. (a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class 1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Piping System Bechtel N/A N/A

  1. 11 Pressurizer Piping to l-MOV-1975 Repaired/Repi 403 aced No Pipe DuBose National Energy Services Inc.

Elbow Consolidated Power Supply Concentric DuBose National Reducer Energy Services Inc.

410658 Ht.#: PZ278 408690 Ht.: F8746 410658 Ht#: F8791 N/A Pipe, 2 1/2 in., Sch. 160, ASME SA-376, Tp. 316 N/A Elbow, Pipe, 2 1/2 In., 90 Deg.,

Sch.160, Long Radius, butt weld, ASME SA403, Gr. WP316 N/A Reducer, Pipe, Concentric, 4 In. X 2 1/2 in., Sch. 120 X 160, ASME SA-403, Gr. WP316 2003 Replacement 2002 Replacement No No No 2003 Replacement

7. Description of Work:

This plan was for the piping/fittings in support of the replacement of 1 -MOV-403, #11 Block Valve for 1 -ERV-402.

Pressurizer Isolation

8. Tests Conducted:

Hydrostatic:E PneumaticC Pressure:

2260 psi.

Nominal Operating Pressure:

Inservice: LI Leakage: i Functional: a]

Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakacie Test of the affected component was performed during the system conditions listed in section 8. of this report.

A Section Xl Surface Examination of the affected component was performed to satisv Section Xl Pre-Service Requirements.

A Section Xl Ultrasonic Examination of the affected component was performed to satisfy Section Xl Pre-Service NDE Requirements.

Code Case N-416-2 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/16/2004 Ownero Owneras Lk-fgnee, TitIe Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have-inspected the components described in this Owner's Report during the period

/.a -a -

3 to

.5-ao -o

,and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bob <<D A.Sgw/f /:,

/-f2.

R0 1)094L15 Pk

-8z-Commissions:

AJt 7 & 3

/Vd //7/ '4.V//

AosI n-XauNia oar Sate adnr

,_ Insmector's Sisma~ture National Board, State, and Endorsements Date: 6 -/7 2003*

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6117/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-024a, MWO No. 1200205334 (address)

(P.O. no.,job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class 1 (b) Applicable Sect )a Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Valve Velan Enginnering 154 N/A Pressurizer Isolation Block Valve 1975 Repalred/Repl No Co.

for l-ERV-404 aced Gate Valve Flowserve 405820 SN: E506T-N/A Valve, Gate, 2 1/2 In., 1703 lb.,

2002 Replacement Yes Corporation 1-2 Sch. 160 Buttwelded, Flowserve P/N W01-25821, ASME SA-351 Gr. CF8M

7. Descripion of Work:

This plan was for the replacement of 1-MOV-405, #11 Pressurizer Isolation Block Valve for 1-ERV-404.

8. Tests Conducted:

Hydrostatic:[]

Pneumatic{]

Nominal Operating Pressure:

Inservice: E Leakage: W Functional: E Pressure:

2260 psi.

Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

a 4

01 q

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section XI Pre-Service NDE Requirements.

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

A Section Xl Surface Examination of the affected component was performed to satisy Section Xl Pre-Service Requirements.

Code Case N416-2 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Reoalr[Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Signed:

Engineering Technician Date:

6/17/2004 Own forO 4ts-feg-nee, riie Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod iB-LD--o3 to 6 -*,- O'

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Dd)O )4 rm 1e 40.

So Ivf AJOFZnZ Io S E Z 7nct7-r Y Commissions: /A 6 r 3/,

10,

)// 7/ / 4J//

Tn/nc Nta oa7rd, Stateo and Endrsee In-snector's Sionature National Board, State, and Endorsemnents Date:

- r 2 --

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the.Provisions of the ASME Code; Section 111, Division 1 Pg. 1 of 2

1. Manufactured and cenified by Flowserve Corporation, 701 First Street, Williamsport, PA 17701 (name and address of N Certificate Holder)
2. Manufactured for Constellation Nuclear, P.O. Box 1609, Lusby, MD 20657 Iname and address of Purchaser)
3. Location of instellation CCNPP, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (name and addressl
4. Model No., Series No., or Type D.D. Gate arawing W0125821 Rev A

CRN N/A

5. ASME Code, Section Ill. Division 1:

1995 1996 1

N/A (editionl (addenda data)

Iclassl (Code Case no.)

6. Pump or valve Valve Nominal Inlet size 2 1/2" Outlet size 2 1/2" lin l(in.)

7 Material Body SA351-CF8M Bonnet SA351-CF8M Disk SA479-316 Bolting Studs: SA453-660B (a)

Cert.

Holder's Serial No.

E506T-1-1 E506T-1-2 E506T-1-3 E506T-14 ziOV

.11 Ib)

Nat'l Board No.

NIA N/A N/A N/A (ci

- Body Serial No.

R15 R16 R17

- R18 (d)

Bonnet Serial No.

R21 R19 R20-R22 Nuts: SA1 94-8M (el Disk Serial No.

6 and 19 5and 18 7 and 20 8 and 21

  • Supplemental information In form of ists. sketrchas. or drawings may be used provided 111 size is 8Ys X 11, (21 information In Iterns I through 4 on this Data Report Is Included on each sheet. 131 each sheet Is numbered and the number of sheets Is recorded at the top of this form.

(11/881 This form 1E00037) maybe obtained from the Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield, NJ07007.2300.

REPAINT V93

FORM NPV-1 (Back -

Pg. 2 of 2

Certificate Holder'i Serial No.

E506T-1-1 II= 4

8. Design conditions 2485 psi 675 F or valve pressure class 1703 11 (pressurel Itemperaturel
9. Cold workingpressurs 4087 psi at 100°F
10. Hydrostatic test 6150 psi. Disk differential test pressure 4500 p31
1. Remarks tei: Bonnet Studs: (30) Trace Code E621 (2) Trace Code B719 Bonnet Nuts: (23) Trace Code TSK (9) Trace Code A288 CERTIFICATION OF DESIGN Design Specificaton certified by John R.Sponsel PE. State MD Reg. no.

17308 Design Report certdfl d by Ronald S. PafeU P.E State PA eDn.PE-035216-E CERTIFICATE OF COMPPUANCE We certify thatthe statements made in this report are correct and that this pump or valve conforms to'the rules for construction of the ASME Code, Section 111, Division 1.

N Certifica a of Authorization No.

N1712 4.15/04 AIts 9

AI no Flowserve Corporation Date.j.M.i&.anme Srgned AW (N Certicate Holderl, N.

uthorlaed reserntyivel CERlIFICATE OF INSPECTION 1, the undersigned, holding a valid commriss3on Issued by'tha National Board of Boiler and Pressure Vessel Inspectors and the State f

'CA;PM of*

PennsvIvania and employed by One Beacon America Insuranco of

_Boston. Mass.

have Inspected the pump, or valve, described in this Date Report on i-i/i25~6~.

AO_

and state that to the best of my knowledge and belief, the Certificate Holder has con.

structad this pump, or valve, In accordance with the ASME Code, Saction 111, Division 1.

By signin9 this certificate, neither the Inspector nor his employer makes any warranty' expressed or Implied, con' component described In this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any ar r

any personal Injury or props a

a I of any kind arising from or connected with this Inspection.

Date-3-o-od F

Pennsylvania 2392 9

adrles 4Ayljzed ictro

[ iNat'l. Bd. ilnd. endorsemental and state ot prov. and no.)

v (1) For manually operated valves only..

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6/1712004 (name) 1650 Calvert Cliffs Parkway; -Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-024b, MWO No. 1200205334 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

ype Code Symbol Stamp: N/A (name)Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Nameof Manufacturers National Other Year Replaced, oz Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Piping System Bechtel 4'CC-10-1002 NIA

  1. 11 Pressurizer Piping to 1-MOV-1975 Repaired/Repi No 405 aced Concentric DuBose National 410658 Ht.#: F8791 N/A Reducer, Pipe, Concentric, 4 In. X 2003 Replacement No Reducer Energy Services 2 1/2 In., Sch. 120 X 160, ASME Inc.

SA-403, Gr. WP316

7. Description of Work:

This plan was for the fitting and work needed to support the replacement of 1-MOV-405, #11 Pressurizer Isolation Block Valve for 1-ERV-404.

8. Tests Conducted:

Hydrostatic:E Pneumaticd Nominal Operating Pressure:

Inservice: E Leakage: i Functional: 2 Pressure:

2260 psi.

Test Temperature:

660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 a 11b FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

A Section Xi Surface Examination of the affected component was performed to satisy Section Xi Pre-Service Requirements.

A Section Xl Ultrasonic Examination of the affected component was performed to satisfy Section Xl Pre-Service NDE Requirements.

Code Case N-416-2 was invoked to satisfy Section Xi required pressure tests. Addtional Section III Exarrinations were-performed (as applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/17/2004 Owner 6r OWn-e~s Designee, Title Certificate of Inservice Inspection I, the undersigned,.holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components descnlbed in this Owner's Report during the period I J v 3 to 6(4&-O

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

-TOMAJ Al~rL4 P

L WCommissions:

Ilt5 r3/,,9t)//7/ A4/1/

U J I

A 7 5 A

7 //,

Insneetor's Sianature National Board, State, and Endorsements Date: 6 - Go 2r0O

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6/17/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-024c, MWO No. 1200205334 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 064 SystemName:

Reactor Coolant System 5.(a) Applicable Construction Code andClass:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

Pipe Support Bechtel 2 1/2"CC-10-1002-N/A

  1. 11 Pressurizer Pipe Support to 1-1975 Repalred/Repl No R12 MOV.405 aced Steel Plate DuBose National 89317-GX Ht.#:

N/A Plate, Steel 1 1/2 In. X 48 In. X 96 1993 Replacement No Energy Services 421J4411 InASME SA-36 Inc.

Nut Consolidated 405854 Ht.# 7307732 N/A Nut, Heavy Hex, 5/8 In. X 11 TPI, 2001 Replacement No Power Supply ASME SA-194 Gr. 2H Rod Mackson Inc.

412170 Ht.#: 622817 N/A Rod, Allthread, 5/8 In. XI ITPI, 2004 Replacement No ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the pipe support work on 2 1/2"CCI0-1002-R12 in support of the replacement of 1-MOV-405, #11 Pressurizer Isolation Block Valve for 1-ERV-404.

8. Tests Conducted:

Hydrostatic:[]

PneumaticO2 Nominal Operating Pressure:

Inservice: f Leakage: E Functional: E Pressure:

NIA psi.

Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

ci"qe i.Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-3 Visual Examination of the affected component support was performed prior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Reolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/17/2004 Owner Kr ~v Deit-d, rifle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod '1-/7-to 6

.and state to the best of my knowledge and belief, the Owner has performed examinations and.taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bOsJLie-d) 4

. 5* i -

/7 Z't a'0,

,w.

aTO1J-iJ A) OWt/2 Ld S

41-7 4 f

Commissions:

V 7r n 3 1, l)

/7/,

at/

I Al N

oard,9 Sae-,aEosens t/

v nsnectnrss Signature National Board, State, and Endorsements Date:

v I

20---

FORM NIS-2 OWNER'S REPORT 1OR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl O.

Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

Date:

6116/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-018, MWO No. 1200301717 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authonzation No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 064 System Name:

Reactor Coolant System 5.(a) Applicable Construction Code and Class:

ASME B&PV Code Sect. 111,1983 Edition, Sum.1983 Add; Class 1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No.

Identification Built Replacemen (Yes or No)

RCP Seal Sulzer Blngham SN: 1C864 NB 1236

  1. 1IB Reactor Coolant Pump 1988 Repalred/Repi Yes Inc.

Mechanical Seal.

aced Seal BGE CCNPP Shops 1200103259 SN:

NB: 1238 Seal, Cartridge Assembly (RCP) 2002 Replacement Yes IC866 875B-3V Complete Sulzer Blngham per FCR 87-0074

7. Description of Work:

This plan was for the replacement of the mechanical seal on #11 B Reactor Coolant Pump.

8. Tests Conducted:

Hydrostatic:FJ Pneumaticf Nominal Operating Pressure:

Inservice: [

Leakage: W Functional: E Pressure:

2260 psi.

Test Temperature:

532 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RevalrlReolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/16/2004 er or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 3

3 to 0 Y

., and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

00AL47-d.S9470N =2 AN.

OLt Commissions: iJfS A3

, SD 117/ enI/

e l

Sav7 Nationa77 BaM St and EJnre Inspector's Signature National Board, State, and Endorsemnents Date: i L s7 0-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

4/1912004 Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Calvert Cliffs Nuclear Power Plant (name)

2. Plant:

Unit:

One_

1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-080, MWO No. 1200303202 (address)

(P.O. no.,job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A Work

-_ bAuthorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

Two (address)

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control

5. (a) Applicable Construction Code and Class:

ASME 831.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Pipe Support Bechtel 1-ACC233X-SUP N/A

  1. l1ChargingPumpDischargeDe-1980 Repalred/Repi Surger Restraint aced No
7. Description of Work:

This plan was for the work on the support/restraint around #11 Charging Pump Discharge De-surger. Shims were used and are not considered Section XI work, but the welding was controlled by a Section Xl WAT which was documented on the R&R.

8. Tests Conducted:

Hydrostatic:[]

PneumaticCl Pressure:

N/A psi.

Nominal Operating Pressure:

Inscrvice: E Leakage: D Functional: E Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 1 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in thUs report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

Engineering Technician Date:

4/19/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 12 -/0 - 0 3 to 2 -.

3-o *, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

9 Commissions: l S-3 A(

A Ap Q n i v-,

,Insnecrns Sirnature National Board, State, and Endorsements Date: -4'K-.23 r

7--

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi Calvert Cliffs Nuclear Power Plant, Inc.

1. Owner:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Date:

6/1512004 Sheet I of 2

2. Plant:

Calvert Cliffs Nuclear Power Plant (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Unit:

One R&R No. 2003-1-072, MWO No. 1200303410 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamnp: N/A (name)

Authorization No.:

N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

One (address)

4. Identification of System:

System Number 052 System Name:

Safety Injection 5.(a)ApplicableConstructionCodeandClass:

ASME B31.1.0 1967 Edition, CCases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Starped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve ITT Hammel-Dahl 694126-006 Plug Assembly Flowserve Corporation 400322 Ht.#: 726176 N/A

  1. 12B Safety Injection Tank, Reactor Safeguards Check Valve leakage drain CV to R.W.T.

N/A Plug & Stem Ass. I In. 1500 lb.

ITT Hammel-Dahl Unbalanced Globe Valve, BGEDRWG 12121-0013, Item #6 1974 Repafred/Repi aced No 2000 Replacement No

7. Description of Work:

This plan was for the rebuilding of the #12B Safety Injection Tank, Reactor Safeguards Check Valve leakage drain 1-CV-648 to R.W.T.

8. Tests Conducted:

Hydrostatic:[

Pneumaticd Pressure:

N/A psi.

Nominal Operating Pressure:

Inservice: E Leakage: E Functional: M Test Temperature:

NIA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet2of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

RevalrlReplacement Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Signed:

Charles H. Ballard Engineering Technician Date:

6/15/2004 Own5er of Owner's Designee, Title-Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 10 -a7-0 3 to 3-9 v and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DEEDj A. SJt41 rL*

M9z r

Z3y add4 me-s -i an r-m - a=, -)

Commissions: AJ8 ' 93 /, Ato //7 /

A-i//f

6 -

4, Inspector's Signature Date:

l 6

200 M AJ

/77 IA/ 4f/S.

National Board, State, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

2/1912004 Sheet 1 of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Calvert Cliffs Nuclear Power Plant

2. Plant:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Unit:

One R&R No. 2003-1-075, MWO No. 1200303794 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Pipe Support Bechtel I

Steel Plate DuBose National Energy Services Inc.

IACC233Z, SUP I

400428 Ht#Y07703 or A351S N/A

  1. 13 Charging Pump Discharge De-1980 Repaired/Repl Surger Restraint aced No No N/A Plate, Steel I/2 In. X 48 In. X 96 In., ASME SA-36 2001 Replacement
7. Description of Work:

This plan was for the work on the support/restraint around #13 Charging Pump Discharge De-surger that was allowed by ES200300606-000.

8. Tests Conducted:

Hydrostatic:M Pneumaticd Pressure:

N/A psi.

Nominal Operating Pressure:

Inservice: O Leakage:E Functional: a Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

Owo__Tln e

Technician Date:

2/19/2004 Owner or Own s Designee, itl Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period

_3 to /g -. 27 - o 3

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

~

9 Conmnissions: WRT A3 41tn 17/, AzT.Aga7L Insnectores Sinature National Board, State, and Endorsements Date: 3-O-20

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

4/20/2004 Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant De (name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

Unit:

One R&R No. 2003-1-081, MWO No. 1200304508 (P.O. no., job no., etc.)

Dpt Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two

4. Identification of System:

System Number 052 System Name:

Safety InJection 5.(a) Applicable Construction Code and Class:

ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 d; Class 3 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Valve Velan Enginnering Co.

SN: 1314 N/A Refueling Water Tank Drain to Miscellaneous Waste Storage Tank Isolation Valve 1975 Repaired/Rep!

aced Yes

7. Description of Work:

This plan was for the welding on 1-HVSI-4163, Refueling Water Tank Drain to Miscellaneous Waste Storage Tank Isolation Valve. This welding is only for tacks on the bonnet assembly to prevent the Yoke Bushing/Nut from backing out.

8. Tests Conducted:

Hydrostatic:Z Pneumatic:

Pressure:

N/A psi.

Nominal Operating Pressure:

inservice: E Leakage: E Functional: E Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2

. FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in SUDDort of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this rules of the ASME Code,Section XI.

RevalrlReplacement conforms to the Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A AYo-Charles H. Ballard Engineering Technician Signed:

Date:

4/20/2004 Owner or Owners Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period / 2_ -1 o It -

/2-

/8? -0 3

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Inspector's Sitwure Date:

5....

200(

Commissions: A49 9U.?/ 14A z

',f 41 7,

National Board, State, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR i REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

6/17/2004 Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Calvert Cliffs Nuclear Power Plant

2. Plant:

(name)

Unit:

One R&R No. 2004-1-009a, MWO No. 1200400341 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

(P.O. no., job no., etc.)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

Type Code Symbol Stamp: N/A (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class:

Two (address)

4. Identification of System:

System Number 041 System Name:

Chemical Volume Control 5.(a)ApplicableConstructionCodeandClass:

ASME B31.1.0 1967 Edition, 1972 Add (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Piping System Bechtel 3"HC-7-1004 N/A

  1. 12 Boric Acid Pump discharge to 1975 I-BS-209, basket strainer.

Repaired/Repl aced No Pipe Tloga Pipe Supply Co. Inc.

Nut Mackson Inc.

76446-GX Ht.#:

L25610 407912 Ht.#:

7307732 409797 Ht.#: 614117 54906-GX Heat Code: D3912 N/A Pipe, 3 In. Sch. 10, ASME SA-376 Tp. 304 N/A Nut, Heavy Hex, s/8 in. X 11 TPI, ASME SA-194 Gr. 2H N/A Rod, Althread, 518 In. X 11 TPl, ASME SA-1 93 Gr. B7 N/A Flange, 3 In., 150 lb., Raised Face, Slip-on, ASME SA-182, Gr. F316 1993 2002 2003 1992 Replacement Replacement Replacement Replacement No No No No Rod Slip-on Flange Mackson Inc.

DuBose Natlonal Energy Services Inc.

7. Description of Work:

This plan was for the replacement of the 3" piping, fittings and fastener material from flange on the upstream side of basket strainer 1-BS-209.

I -HVCVC-236 to the

8. Tests Conducted:

Hydrostatic:M PneumaticC Pressure:

1 00 psi.

Nominal Operating Pressure:

Inservice:E Leakage:R Functional: a Test Temperature:

1 50 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I 1 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

q tA Sheet 2 of 2 I -FORM NIS-2 (Back)

9. Remarks:

A Section Xi Svstem Leakaae Test of the affected component was performed durina the system conditions listed in section 8. of this report.

Code Case N-416-2 was invoked to satisfy Section XI required Pressure tests. Addtional Section III Examinations were performed (as anolicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this conforms to the rules of the ASME Code,Section XI.

RenalrlReolacement Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Signed:

Charles H. Ballard Engineering Technician Date:

6/17/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period.

3 -o to 3 -5 *Y

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DoAM-u A - SH14*-P/I'L FAmt /YIZ.

o4tN 46DA6S k-7 7WCF~f Z Commissions
AJIR9 9-3J 3

Ai9 /17/,

//

_ _l Dt Inspector's Signture Date:

60 - / 7 200v National Board, State, and Endorsements

F6RM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Calvert Cliffs Nuclear Power Plant, Inc.

1. Owner:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Date:

6/1712004 Sheet I of 2 (address)

Calvert Cliffs Nuclear Power Plant

2. Plant:

(name)

Unit:

One R&R No. 2004-1-009b, MWO No. 1200400341 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two

4. Identification of System:

System Number 041 SystemName:

Chemical Volume Control 5.(a) Applicable Construction Code and Class:

ASME B31.1.0 1967 Edition, 1972 Add (b) Applicable Sect Xl Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

.ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Pipe Support Bechtel 3"HC-7.1004,H2/R3 N/A Pipe Support on CVCS Sys.

upstream of 1-BS-209, basket strainer.

1975 Repilred/Repl aced No

7. Description of Work:

This plan was for the removal and rewelding of pipe support 3"HC-7-1004, H2 / R3, upstream of 1-BS-209, basket strainer.

8. Tests Conducted:

Hydrostatic:E PneumaticC]

Pressure:

N/A psi.

Nominal Operating Pressure:

Inservice: E Leakage: []

Functional: E Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was Derformed in support of this activity, Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Reoalr/Renlacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Sta-mp:

N/A Certificate of Authorization No.: N/A Expiration Date:

N/A Charles H. Ballard Signed:

Engineering Technician Date:

6/17/2004 Owner or Owfr's Deignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid cormnission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period A v /

to S -/ Y e"

, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

&0,4Ai-O A &8hffD ftA7 MfO> lJS Z72 Commissions: A18 3 8X3 1 /A 11//7/

.4A4J0 Insnectnr's Sianature National Board, State, and Endorsements Date: /7 M

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl Calvert ClIffs Nuclear Power Plant, Inc.

1. Owner:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

Date:

5/20/2004 Sheet 1 of 2

2. Plant.

Calvert Cliffs Nuclear Power Plant Unit:

One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2004-1-017, MWO No. 1200401939 (address)

3. Work Performed by.

Calvert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

(P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section XI Class:

Two

4. Identification of System:

System Number 052 SystemName:

Safety Injection 5.(a)ApplicableConstructionCodeandClass:

ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Rod Eye Grin neil Pipe Support Bechtel 12" GC-9-1003-R6 N/A Sarety Injection Piping Support 1975 Repalred/Repl aced No Rod Eye Grinnell Bracket Corporation

7. Description of Work:

45824 NIA Bracket, Rod Eye, Rear Assembly, 2 1/2" size, Grinnell Fig. 201, Item 17, ASME SA-216, Gr.WCB 1999 Replacement No This plan was for the replacement of the lower rod eye bracket on Snubber 1-52-34, on support 12"GC9-1 003-R6.

8. Tests Conducted:

Hydrostatic:M Pneumaticfj Nominal Operating Pressure:

Inservice: El Leakage: M Functional: E Test Temperature:

NIA Deg. F Pressure:

N/A psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Z0 d -bO1 0>/'=d4/ ACW j3. J A 8AB PE Orf oF AJ1-ak RD p

A00f P/ot7

$et2 of 2 FORM NIS.2 (Back)

9.

e,=arks:

No Sectdon Xl Pre-Service NDE was grftrned in suoyort of ths actM Applicable Manufactwc's Data Repmu to be Attacbed

.~'

. Certificate of Compliance We ear that tlt stamtrnade hi rLport aetrect Ad tbat this

-8421108212e rdes of ibe ASO Code, SwdcronM.

Type coa Symbol Stapp:

N/A Cerdficate of Autorizadon No.: NIA xpiratdon Date NIA Sipe

/

Charles H. 3allard Signue 4MS f

Date:+/-O t

So,20Q4 Certificate of lnservice Inspection 1, the undesigned, holding a valid coovuhIon isuad by dte Nadonul Board of Boiler and Ptesgure Vessel laspectors and dmc State of Mayland an employed by ABS Conmufi of oustom TX have inspected th cwrmpotenb deribed in tbis Ow s Repot ing thepegiod

.2-A to astateto te benof Imowledge and belief, the Own= bAs performed raminvions owd taken co ticdve =ea=u descnbed in this Ovrs Report in accordance with the xarirea of the ASM Code Secion

L By siS this certficte neither 1e Isp!eTtr wr his enmpljdybrakes aty warant exprwed or implie4 canjceg dw examinarios and coucive maswu desenbed in this Owncs fepoit fPfwre, neirdh the Inpector nor his employer shall b liable i any mrer for any pesonal irjuy or property 4gtwga ofa lu of any kd adsig f0om o connected wih thu isspecdox g6 1.a-771 1Hv

//(5

_otiana~oa 4 rm

.Stoand Enaorsemants Pats: 6- -

.Z 5

200j34

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc.

(name)

Date:

6/21/2004 Sheet 1 of AL 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

2. Plant:

Calvert Cliffs Nuclear Power Plant (name)

Unit: Common R&R No. SNUB-0-004, MWO No. SNUB POOL 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

3. Work Performed by:

Calvert Cliffs Nuclear Power Plant Dept.

(name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A Authorization No.: N/A Exp Date: N/A Section X Class:

1, 2, & 3 (address)

4. Identification of System:

System Number 065B SystemName:

Seismic Snubbers 5.(a) Applicable Construction Code and Class:

ASME B31.7 1969 Ed, Sum.1971 Add. Class I or Combustion Eng. Spec 8067-487-503 (b) Applicable Sect X1 Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME

Repaired, Code Year Replaced, oi Stamped Built Replacemen (Yes or No)

Name of Name of Componet Manufacturer Manufacturers Serial Number National Board No.

Other Identification Snubber Pool Grinnell Corporation Snubber Pool Snubber Snubber Grinnell Corporation Grinnell Corporation 59013-GX SN: 32323 59013-GX SN: 32325 411825 SN: 35846 59013-GX SN: 32321 N/A Hydraulic Shock and Sway Suppressor N/A Hydraulic Shock and Sway Suppressor, 1 1/2 In. Bore X 5 In.

Stroke, Grinnell Fig. 200 Opt. 1 NIA Hydraulic Shock and Sway Suppressor, 1 1/2 In. Bore X 5 In.

Stroke, Grinnell Fig. 200 Opt. I N/A Hydmullc Shock and Sway Suppressor, Size: 3 X 5 In.

Stroke, Anvil Fig. 3306N N/A Hydraulic Shock and Sway Suppressor, 1 1/2 In. Bore X 5 In.

Stroke, Grinnell Fig. 200 Opt. 1 1975 RepaIred/RepI aced No 1991 Replacement 1991 Replacement 2004 Replacement 1991 Replacement No No No No Snubber Anvil International Inc. Grinnell Supports Snubber Grinnell Corporation

7. Description of Work:

This plan was for the continued control of the Snubber Pool and documentation of new components/parts added to the Snubber Pool per Section XI 1998, IWA-4132, Items Rotated From Stock. This plan covers all Snubber work from the end of Unit #2, 2003 outage through to the end of Unit #1, 2004 outage.

8. Tests Conducted:

Hydrostatic:D PneumaticC Pressure:

NIA psi.

Nominal Operating Pressure:

Inservice: E Leakage: a Functional: E Test Temperature:

N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Qh..f a 4f J FORM NIS2 (Back)

9. Remarks:

A Section Xl VT-3 Visual Examination of the affected component suDport was performed prior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Revalr/Reptacement conforms to the rules of the ASME Code, Section X1.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.: N/A Expiration Date:

NIA

_g4

/

Charles H. Ballard Signed:

D e, Tite Engineering Technician Date:

6/21/2004 1wnaror O%;nee Desigznee~,Titlc~-"

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod St-;'3-D V/

to

-aI -9ov

,and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Reports Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DOD4A-O A.SH479/As'1 1-Ab

,M IjVjA CoME7 ek)2 7 Commissions: AJA 9A A 4 ABASIJ, lfI/f 3

- --2 I

-e Z7" v /3 /77 97, U

0 ss

, P Inspector's Signature Date:

{ -is?.

200 4" National Board, State, and Endorsements