ExeklsnSM Exelon Generation Company, LLC www.exeloncorp.com Nuclear LaSalle County Station 2601 North 21 Road Marseilles, IL 61341-9757 May 7, 2004 10 CFR 50.55a(g)
United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 LaSalle County Station, Unit 1 Facility Operating License No. NPF-1 1 NRC Docket No. 50-373
Subject:
Post-Outage 90-Day Inservice Inspection Summary Report
Reference:
Milton H. Richter (ComEd) letter to Dr. Thomas E. Murley (NRC), "Structural Margin Evaluation for Reactor Pressure Vessel Head Studs," dated October 3, 1991 10 CFR 50.55a, "Codes and standards," paragraph (g) requires Exelon Generation Company (EGC), LLC to maintain an Inservice Inspection Program in accordance with the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. This report is submitted in accordance with the requirements of ASME Code Section Xl, Article IWA-6200, Paragraph IWA-6230.
Enclosed is the Post-Outage 90-Day ISI Summary Report for examinations, repair/replacement activities, and tendon testing/inspections performed between the end of the ninth refuel outage on February 4, 2002, through the end of the current refuel outage. This refuel outage was the tenth for LaSalle County Station Unit 1. It started January 13, 2004, and ended February 12, 2004. This refuel outage was the first scheduled for the Third Inspection Period of the Second Inspection Interval, effective from November 23, 1994, through October 11, 2006, for LaSalle County Station Unit 1. The report also includes two repair/replacement activities completed during the eighth refueling outage, that were omitted in error from a previous 90-Day ISI Summary Report.
May 7, 2004 U.S. Nuclear Regulatory Commission Page 2 LaSalle County Station Unit I is owned and operated by EGC, whose address is:
200 Exelon Way Kennett Square, PA 19348 LaSalle County Station Unit I has an authorized power level of 3489 MWt and began Commercial Operation on January 1, 1984.
We certify that, to the best of our knowledge and belief, the statements made in this report are correct, and the examinations and corrective measures, as applicable, conform to the rules of the ASME Boiler and Pressure Vessel Code, Section Xl.
Should you have any questions concerning this letter, please contact Mr. Glen T. Kaegi, Regulatory Assurance Manager, at (815) 415-2800.
Respectfully, George P. Barnes Site Vice President LaSalle County Station Attachment cc:
Regional Administrator - NRC Region IlIl NRC Senior Resident Inspector - LaSalle County Station
Attachment Post-Outage 90-Day ISI Summary Report INTRODUCTION The Inservice Inspection Summary Report addresses examinations, repair/replacement activities, and Containment Inservice Inspections (CISI) performed between the end of the previous refuel outage, (L1 R09)
February 4, 2002, through the end of the current refuel outage (L1 R10). This refuel outage was the tenth for LaSalle County Station Unit 1. It started January 13, 2004 and ended February 12, 2004. This refuel outage was the first scheduled for the Third Inspection Period of the Second Inspection Interval, effective from November 23, 1994, through October 11, 2006, for LaSalle County Station Unit 1. Paragraph IWA-2430(e) of the American Society of Mechanical Engineers (ASME) Code Section Xl allows an Inspection Interval to be extended for a period of time equivalent to the duration of a continuous outage that exceeds six months. The Second Inservice Inspection Interval is divided into three successive inspection periods as determined by calendar years of plant service within the inspection interval.
Identified below are the period dates for the Second Inservice Inspection Interval as defined by Inspection Program B. In accordance with IWB-2412(b),
the Inspection Periods specified below may be decreased or extended by as much as one year to enable inspections to coincide with LaSalle County Station's refuel outages.
Unit 1, Period 1 (November 23, 1994 through October 11, 1999**)
Unit 1, Period 2 (October 12, 1999 through October 11, 2003)
Unit 1, Period 3 (October 12, 2003 through October 11, 2006)
Inservice Inspection (ISI) examinations, Augmented Inservice Inspection (AISI) examinations, Containment Inservice Inspections (CISI), and Preservice Inspections (PSI) were completed prior to and during the refuel outage as required by the Code of Federal Regulations, Technical Requirements Manual, ASME Boiler and Pressure Vessel Code, Section Xl, 1989/1998 Edition, and the applicable requirements of the Performance Demonstration Initiative (PDI).
Personnel from General Electric Nuclear Energy (GENE) Inspection Services and Exelon Nondestructive Examination Services group (NDES) performed the Non-Destructive Examinations (NDE), Magnetic Particle (MT), Liquid Dye Penetrant (PT), and manual and/or automated Ultrasonic (UT) techniques that were used during these inspections. All Intergranular Stress Corrosion Cracking (IGSCC) examinations were completed by personnel qualified for the detection and discrimination of IGSCC Cracking in accordance with the PDI.
NDES provided necessary resolution of technical problems, reviewed all ISI personnel qualifications, and all visual, surface, and volumetric examination results.
1
Visual examinations of reactor vessel internals, component supports, and piping pressure tests were performed by GENE personnel, Exelon Generation Company (EGC), LLC, employees of the LaSalle County Station Programs Engineering Group and NDES personnel. These individuals were appropriately certified as ASME Code Section Xl Visual Examiners to EGC's written practice. An underwater camera was used for the visual inspection of the reactor vessel internals. The camera was proven capable of resolving 0.001" and 0.0005" stainless steel wires while underwater and, in the same lighting conditions found during the actual inspection.
The services of an Authorized Nuclear Inservice Concrete Inspector (ANIC) was provided by Hartford Steam Boiler Inspection & Insurance Co. of Connecticut, 2443 Warrenville Road, Suite 500, Lisle, IL 60532.
Mr. Rocky W. White, ANIC, State of Illinois #1927, reviewed written Nondestructive Examination procedures, personnel qualifications, instrument and material certifications, ASME Code Section Xl examination results, Owner's Reports of Repair or Replacement (Form NIS-2), and the Owner's Data Report for Inservice Inspection (Form NIS-1).
II. SCOPE OF INSPECTIONS The ISI Summary Report is provided with tables that consolidate the extent and results of inspections performed between the end of the previous refuel outage (L1 R09), February 4, 2002, through the end of the current refuel outage (L1 R1 0). An explanation of all abbreviations used is in Attachment 3 of the Summary Report.
Table A provides a listing of all completed ASME Code Section Xl examinations for this refuel outage with the exception of component support examinations and pressure testing which are addressed separately. Table A is divided by ASME Code Category with a description of the item(s) examined, including the examination type(s), and the examination result(s).
Table B provides a listing of all (AISIs). These are not ASME Code Section Xl requirements, but are either additional examination area requirements, increased frequency requirements, or combinations of these which are requested by the Nuclear Regulatory Commission (NRC). Others have been deemed prudent in view of EGC and industry experience. Table B also gives a description of the item(s) examined as well as the examination type(s), and examination result(s). Table B includes the following categories:
2
TYPE 1A - These are ASME Code Section Xl Category B-F and B-J welds of the high energy line break exclusion regions, which are identified in the Safety Analysis Report (SAR) and examined as required by the NRC.
BWRVIP These examinations are of austenitic stainless steel piping for the detection of intergranular stress c6rrosion cracking (IGSCC).
REACTOR VESSEL INTERNALS AISI - These examinations include inspection of reactor internal components which have been required by the NRC such as core spray spargers and piping. These have been adopted by EGC through its commitment to the Boiling Water Reactor Vessel and Internals Project (BWRVIP). Other examinations, such as the steam dryer and steam separator, were deemed prudent from industry experience.
MISCELLANEOUS AISI -
Pursuant to LaSalle County Station's commitment to the NRC (reference letter), the AISI examinations included an augmented "End-Shot" UT examination of 100% (68 total) of the reactor pressure vessel closure studs.
The "End Shot" UT examination was completed using procedures, calibration standards, and personnel which met all applicable requirements of the 1989 Edition of ASME Code Section Xl, and the PDI.
Table C provides a listing of all completed ASME Code Section Xl Class 1 and 2 component support examinations for this outage. Table C gives the support number(s), examination type(s), and examination result(s). Table C is divided by ASME Code Class.
Table D provides a listing of pressure testing of ASME Code Section Xl Class 1 & 2 piping and components completed during the period between the Ll R09 and LI R10 refuel outages. As applicable, Code Case N-498-1, "Alternative Rules for 1 0-Year Hydrostatic Testing for Class 1, 2, and 3 Systems Section Xl, Division 1," is utilized during the Third Inspection Period. ASME Code Class 1 components and piping were examined using the VT-2 method during the system leakage test conducted at 1040 psig prior to reactor start-up, within the nominal operating pressure range of the reactor pressure vessel associated with 100% rated reactor power. Pressure testing will be ongoing throughout the remainder of the Third Inspection Period.
3
Table E is a listing of ASME Code Section Xl Class 1 and 2 repair/replacements which have been completed since the previous refuel outage and those completed during the tenth refuel outage of Unit 1, Articles IWA-4000 and IWA-7000. This includes the documentation package Nuclear Work Request or Work Order number which served to implement the applicable activity and a short description. The documentation packages are on file at LaSalle County Station. Each activity has been certified on the Owner's Report of Repair or Replacement, which will serve as documentation of these repair/replacements. The table includes two Work Orders
- 980107466 and #980107485 that were completed during the eighth refueling outage, that were omitted in error from a previous 90-Day ISI Summary Report. This has been documented in the Corrective Action Program under Condition Report #214816.
The name of each major component or appurtenance inspected during the tenth refuel outage is listed on Form NIS-1 (Attachment 1) in column #1. This includes the reactor pressure vessel and the Class 1 piping system. A detailed list of components or appurtenances inspected appears in the abstracts listed as items 13, 14, and 15 on Form NIS-1. The descriptions including size, capacity, material, location, and drawings to aid in identification of the components or appurtenances have been previously submitted, including the N-5 ASME Code Data Reports and the Second 10-Year ISI Plan.
This information was not included in the ISI Summary Report. These documents are on file at LaSalle County Station. This also applies to the Preservice (PSI) and Inservice Inspection (ISI) Summary Reports.
III.
SUMMARY
OF RESULTS AND CORRECTIVE ACTIONS The ASME Code Section Xl ISI results obtained this refuel outage were compared with the Preservice and InService results. The following is a summary of the results and corrective actions taken.
- 1.
ASME Code Section Xl Components Recordable indications were detected in ASME Code Section Xl components and other non-code components, during augmented examinations as discussed below or in the applicable Tables. All indications detected in ASME Code Section Xl components were evaluated against the applicable acceptance standards.
During the period of time covered by this report examinations and tests for the Unit 1 ASME Code Section Xl Class CC post tensioning system were performed. The following conditions have been identified and are being reported as required by 10 CFR 50.55(a):
4
During the examination of tendons, free water was identified in either the grease can or anchorage of the following tendons:
Field End Shop End I V010A TV012A
<1 ounce 1 ounce Field End Field End I V026A I V028A X 1 ounce
_ 12 ounces I I Shop End I V013A 1 2 ounces I Shop End I V044C I 1 ounce Field End V058C 2 ounces The difference between the amount of sheating filler grease removed and the amount replaced exceeded 10% of the tendon net duct volume in the following tendons:
V001A 11.16%
V002A 22.32%
V004A 16.57%
V005A 29.76%
V006A 32.29%
V009A 10.74%
V010A 13.65%
V011A 15.22%
V014A 15.53%
V018A 19.73%
V027A 14.71%
V028A 15.45%
V030A 17.96%
V005C 10.79%
Grease leakage was detected during examination of the containment surface near the field end anchorages of tendons V027A, V029A, V004B and V020B.
Examination of tendons identified degradation in the form of broken wires found on the following:
V002A 10 of 90 wires broken V003A 72 of 90 wires broken. This tendon was replaced.
V010A 4 of 90 wires broken V012A 7 of 90 wires broken. This tendon was replaced.
V013A 77 of 90 wires broken. This tendon was replaced.
V029A 58 of 90 wires broken. This tendon was replaced.
V014A 2 of 90 wires broken V030A 1 of 90 wires broken Five 'A" tendons and all thirty "B" tendons are inaccessible for examination during power operations. Degradation of the tendons is due to water-induced corrosion by failure of the water intrusion barriers and, aided by a loss of the corrosion protection medium (grease) in the top region of the accessible "A" tendons. The design of the inaccessible tendons incorporates a welded cover that prevents this type of degradation. To confirm this conclusion, a corrective action has been generated to inspect one inaccessible "A" and "B" tendon at the next scheduled refueling outage. This inspection is tracked by Action Tracking Item #157920, Assignment 33.
The results of the examinations and tests of the Unit 1 ASME Code Section Xl Class CC post tensioning system are in the process of being reviewed and evaluated. If required, additional information will be reported in the next subsequent Unit 1 ISI Summary Report.
5
- 2.
Steam Dryer Based on LaSalle County Station experience, an augmented visual examination of the steam dryer is completed during each refuel outage. The steam dryer contains numerous indications that were recorded during previous examinations. Areas where historically indications were identified include the lifting eye bracket welds, upper dryer bank vertical welds, upper support ring, drain channel welds, and dryer bank panels. During the tenth refuel outage, specific inspections as recommended by SIL 644 Rev. 1 were performed and new indications were identified on the end panels for banks A, B, D, and on a guide rod follower bracket. The two indications detected on the end panels for banks A and D were evaluated as acceptable as-is with no repair required in accordance with EC #346971. The indication on the end panel for bank B and the guide rod follower bracket were stop drill repaired to prevent future crack propagation. Condition Reports #195996 (bank B) and #196072 (guide bracket) were generated to document these conditions. These examination results have been documented on the GENE examination data sheets.
- 3.
Steam Separator Based on LaSalle County Station experience, an augmented visual examination of the steam separator is completed during each refuel outage.
During this examination in L1R10, no new indications were observed. A previous indication was noted on a gusset. This indication was previously identified and no Condition Report was generated. These examination results have been documented on the GENE examination data sheets.
- 4.
Jet Pumps During the tenth refuel outage, an augmented UT examination was completed on 100% (20 total) of the jet pump hold down Beams. The UT technique used interrogated the bolt hole area (BWRVIP-41 location BB-1), the beam ears (BWRVIP-41 location BB-2) and the beam transition area designated BB-3.
The examination detected one potentially detrimental indication in the bolt hole area of the beam on jet pump 15. Condition Report #196552 was generated to document this indication. This jet pump beam was replaced in LI R10 with a new design, weldless, rachet-lock beam. After replacement, visual examination revealed a gap between one adjusting screw and the respective inlet mixer. A permanent repair wedge was installed to eliminate the gap. The beam replacement and wedge installation was completed under Work Order
During Ll R10, augmented inspection of jet pump main wedges was performed. The VT-1 inspections revealed wear on 10 of the 20 wedges. The wedge on jet pump 19, the rod was worn and the upper nut on the rod had worn into the wedge bracket. As a result, all of the auxiliary wedges were inspected by VT-1. No additional auxiliary wedge wear was detected, but the ratchet teeth on two of the auxiliary wedges were not fully engaged.
Inspections were performed to determine if gaps existed between the jet pump inlet mixers and the set screws. Gaps were identified on nine jet pumps.
6
These inspection results were documented in Condition Report #197310. For sample expansion riser brace RS-8 and RS-9 welds were inspected by EVT-1.
Indications were noted on the RS-9 welds on both the jet pump 5 and 6 sides of the jet pump 5/6 riser brace. One indication was also noted on the jet pump 9 side of the jet pump 9/10 riser brace. Inspection results were documented in Condition Report #199081. Flaws at this location have been observed at other Boiling Water Reactors.
The main wedge wear and the lack of engagement of the ratchet teeth were accepted as-is under EC #347046. Due to the wedge rod and nut wear on jet pump 19, the inlet mixer was removed and replaced with a spare as authorized by EC #347046 and EC #347052. An auxiliary wedge was installed at locations where there was a gap between the jet pump inlet mixer and a set screw. Twelve auxiliary wedges were installed under WO #554306. The three riser brace indications were accepted as-is for one cycle under design analysis L-003012. This analysis was performed in accordance with the guidance provided in BWRVIP-03 and BWRVIP-41.
When the inlet mixer for jet pump 19 was removed, examinations of areas made accessible below the core plate were performed. Examinations included accessible portions of bottom head cladding in vicinity of jet pump 19, surfaces/welds on CRD stub tubes and guide tubes, shroud to RPV weld H-9 located below the shroud support plate, jet pump adapter welds on 18 and 20, and a general overview of the bottom head. No recordable indications were noted.
A root cause evaluation was performed and determined that one of the causes of the jet pump wedge wear, was operation with high slip joint differential pressure (low M-ratio) that puts the jet pumps under hydraulic conditions, and contribute to abnormal inlet mixer vibration and associated wedge wear. As a result of the root cause, a clamp was installed on all twenty jet pumps at the slip joint. The clamps were installed under WO #659181.
- 5.
Core Spray Piping During the tenth refuel outage, an augmented UT examination was completed on accessible core spray piping welds internal to the reactor vessel. The examination detected five relevant indications; one on weld BP4a and two on welds DP6 and DP5. Condition Report #195988 was generated to document these indications. The indications were accepted as-is for one cycle under design analysis L-003008.
7
- 6.
ASME Code Section Xl Piping & Component Support Examinations Piping and component supports were inspected (52 total) during this refuel outage. These were distributed between ASME Code Section Xl Class 1 and 21D+ supports as follows:
- ASME Code Class 1 - 34 supports.
- ASME Code Class 2/D+ - 18 supports.
Two rejectable indications were detected during examinations.
FW02-1158X had a loose nut on the pipe clamp load bolt. Condition Report
- 195554 was initiated to disposition the indication. The loose nut condition was corrected under Work Order #656884. Support FW02-1158X was re-examined and found to be acceptable.
RH04-1505C had a loose nut on the hanger rod connection to the pipe clamp load bolt. Condition Report #195900 was initiated to disposition the indication.
The loose nut condition was corrected under Work Order #657112. Support RH02-1505C was re-examined and found to be acceptable.
As required by ASME Section Xl Code Case N-491-1, "Alternative Rules for Examination of Class 1, 2, 3, and MC Components Supports of Light-Water Cooled Power Plants Section Xl, Division 1," sample expansion examinations were completed for the two rejectable indications. No further detrimental indications were detected.
8
the set screws. Gaps were identified on nine jet pumps. These inspection results were documented in Condition Report #197310. For sample expansion riser brace RS-8 and RS-9 welds were inspected by EVT-1. Indications were noted on the RS-9 welds on both the jet pump 5 and 6 sides of the jet pump 5/6 riser brace. One indication was also noted on the jet pump 9 side of the jet pump 9/10 riser brace. Inspection results were documented in Condition Report #199081. Flaws at this location have been observed at other Boiling Water Reactors.
The main wedge wear and the lack of engagement of the ratchet teeth were accepted as-is under EC #347046. Due to the wedge rod and nut wear on jet pump 19, the inlet mixer was removed and replaced with a spare as authorized by EC #347046 and EC #347052. An auxiliary wedge was installed at locations where there was a gap between the jet pump inlet mixer and a set screw. Twelve auxiliary wedges were installed under WO #554306. The three riser brace indications were accepted as-is for one cycle under design analysis L-003012. This analysis was performed in accordance with the guidance provided in BWRVIP-03 and BWRVIP-41.
When the inlet mixer for jet pump 19 was removed, examinations of areas made accessible below the core plate were performed. Examinations included accessible portions of bottom head cladding in vicinity of jet pump 19, surfaces/welds on CRD stub tubes and guide tubes, shroud to RPV weld H-9 located below the shroud support plate, jet pump adapter welds on 18 and 20, and a general overview of the bottom head. No recordable indications were noted.
A root cause evaluation was performed and determined that one of the causes of the jet pump wedge wear, was operation with high slip joint differential pressure (low M-ratio) that puts the jet pumps under hydraulic conditions, and contribute to abnormal inlet mixer vibration and associated wedge wear. As a result of the root cause, a clamp was installed on all twenty jet pumps at the slip joint. The clamps were installed under WO #659181.
- 5.
Core Spray Piping During the tenth refuel outage, an augmented UT examination was completed on accessible core spray piping welds internal to the reactor vessel. The examination detected five relevant indications; one on weld BP4a and two on welds DP6 and DP5. Condition Report #195988 was generated to document these indications. The indications were accepted as-is for one cycle under design analysis L-003008.
7
- 6.
ASME Code Section Xl Piping & Component Support Examinations Piping and component supports were inspected (52 total) during this refuel outage. These were distributed between ASME Code Section Xl Class 1 and 2/D+ supports as follows:
- ASME Code Class 1 - 34 supports.
- ASME Code Class 2/D+ - 18 supports.
Two rejectable indications were detected during examinations.
FW02-1158X had a loose nut on the pipe clamp load bolt. Condition Report
- 195554 was initiated to disposition the indication. The loose nut condition was corrected under Work Order #656884. Support FW02-1158X was re-examined and found to be acceptable.
RH04-1505C had a loose nut on the hanger rod connection to the pipe clamp load bolt. Condition Report #1 95900 was initiated to disposition the indication.
The loose nut condition was corrected under Work Order #657112. Support RH02-1505C was re-examined and found to be acceptable. I As required by ASME Section Xl Code Case N-491-1, "Alternative Rules for Examination of Class 1, 2, 3, and MC Components Supports of Light-Water Cooled Power Plants Section Xl, Division 1," sample expansion examinations were completed for the two rejectable indications. No further detrimental indications were detected.
8
LASALLE COUNTY STATION UNIT I TENTH REFUEL OUTAGE ASME CODE SECTION XI
SUMMARY
REPORT
TABLE OF CONTENTS
- 1.
INTRODUCTION II.
SCOPE OF INSPECTIONS Table A ASME Code Section XI Examinations Table B Augmented Inservice Inspections AISI Table C ASNIE Code Section XI Component Support Examinations Table D ASME Code Section XI Pressure Testing Table E Class I & 2 Repair/Replacements III.
SUMMARY
OF RESULTS, EVALUATIONS, AND CORRECTIVE ACTIONS IV.
ATTACHMENTS
- 1. NIS-1 Form
- 2. NIS-2 Forms
- 3. Abbreviations
TABLE A ASME CODE SECTION XI ISI INSPECTIONS ASME CATEGORY R-A ITEM #
ITEM DESCRIPTION EXAM TYPE RESULT 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 FW-1001-20 FW-1001-21 FW-1001-21A FW-1001-68 FW-1002-20 FW-1002-21 FW-1002-21A LP-100 1-02 MS-1001-15 MS-1003-03 MS-1004-03 MS-1004-09 MS-1046-14 RH-1001-02 RH-1002-02 RH-1002-05 RH-1002-06 RH-1004-24 RH-1077-30 RI-1002-15 RI-1002-16 RT-1001 -03 UT/MT UT/MT UT/MT UT UT/MT UT/MT UT/MT UT UT UT UT UT UT/MT UT UT UT UT UT UT UT UT UT NRI/PSI RECORDABLE INDICATIONS DURING PSI UT ACCEPTED PER IWB-3514 GEOMETRY/NRI/PSI NRI GEOMETRY/NRI/PSI RECORDABLE INDICATION DURING PSI UT ACCEPTED PER IWB-3514 NRIIPSI NRI NRI NRI NRI NRI NRI/PSI GEOMETRY NRI NRI NRI NRI NRI NRI NRI NRI ASME CATEGORY B-G-1 1
2 3
4 5
6 7
8 9
10 II 12 13 14 I B33-F060A-4, 2.75" NUTS lB33-FO60A-4, 2.75" WASHERS lB33-FO60A-4, 2.75" FLANGE lB33-FO60A-4, 2.75" STUDS IB33-FO60B-4, 2.75" NUTS IB33-FO60B-4, ONE 2.75" NUT IB33-F060B-4, 2.75" WASHERS IB33-F060B-4, 2.75" FLANGE 1B33-F060B-4, 2.75" STUDS 1B33-F060B-4, ONE 2.75" STUD RPV NUTS 47 THRU 68 RPV WASHERS 47 THRU 68 RPV LIGAMENTS 47 THRU 68 RPV STUDS 47 THRU 68 VT-i VT-i VT-i UT VT-I VT-I VT-I VT-I UT UT VT-I VT-I UT UT NRI NRI/PSI NRI NRI ONE CORRODED, REPLACED NRI/PSI NRI/PSI NRI NRI NRI/PSI NRI NRI NRI NRI ASME CATEGORY B-G-2 I
2 3
4 5
6 7
8 9
10 GEL-1009-H GEL-I009-J MS-1003B-17 MS-1003B-21 MS-1003B-25 RR-1006B-06 RT-1OOIB-18A RT-lOOIB-18B IB21-F028C IB21-F028C VT-I VT-i VT-i VT-i VT-i VT-i VT-I VT-I VT-I VT-I NRI/PSI NRI NRI NRI NRI NRI NRI NRI (3) CORRODED, REPLACED NRI/PSI ON REPLACEMENTS
TABLE A (CONT'D.)
ASME CODE SECTION XI ISI INSPECTIONS ASME CATEGORY B-G-2 ITEM #
11 12 13 14 15 16 ITEM DESCRIPTION IB21-F028D IB21-F028D IB21-FOIOA IB21-FOIOB IB33-F023A lE51-F065 EXAM TYPE RESULT VT-I VT-I VT-I VT-I VT-I VT-I (10) THREADS DAMAGED, REPLACED NRI/PSI ON REPLACEMENTS NRI/PSI NRIIPSI NRI NRI ASME CATEGORY B-K 2
2 RH40-1006C RH53-1002C RH53-1550X RH53-1551X R124-1016X MT MT MT MT MT NRI RECORDABLE INDICATION ACCEPTED PER IWB-3415-4 NRI NRI NRI 3
4 5
ASME CATEGORY B-M-2 1
2 3
4 4
5 6
IB21-FOIOA IB21-FOIOB IB21-F028C IB21-F028D IB33-F023A IE12-F008 IE51-F065 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 NRI/PSI NRI/PSI NRI NRI NRI NRI NRI ASME CATEGORY B-N-I I
2 3
SURFACES ABOVE THE CORE VT-3 SURFACES BELOW THE CORE VT-3 GENERAL EXAM OF RPV BOTTOM HEAD VT-3 BOTTOM HEAD SURFACES AT JET PUMP #19 VT-3 NRI NRI NRI NRI 4
ASME CATEGORY B-N-2 I
2 3
4 5
6 7
8 9
10 I11 12 (3) CORE SPRAY PIPING ATT. EVT-1 (2) FEEDWATER SPAGER ATT. EVT-I DRYER SUPPORT LUGS EVT-I LOWER SURVEILLANCE LUGS VT-I UPPER SURVEILLANCE LUGS VT-3 ACCESSIBLE CRD STUB TUBE WELDS VT-3 ACCESSIBLE CRD STUB TUBE SURFACES VT-3 ACCESSIBLE SHROUD SUPPORT TO RPV WELD BOTTOM SIDE VT-3 SUPPORT PLATE GUSSET SURFACES VT-3 SUPPORT PLATE GUSSET TO RPV WELDS EVT-I SUPPORT PLATE SURFACES VT-3 SUPPORT PLATE TO SHROUD CYLINDER WELD EVT-I NRI NRI WEAR, ACCEPTABLE NRI NRI NRI NRI NRI NRI NRI NRI NRI
TABLE A (CONT'D.)
ASME CODE SECTION XI ISI INSPECTIONS ASME CATEGORY B-N-2 ITEM #
ITEM DESCRIPTION EXAM TYPE RESULT 13 DRYER HOLD DOWN LUGS VT-3 NRI ASME CATEGORY C-A I
IRH-HXIB-05 UT NRI 2
IRH-HXIB-06 UT NRI ASME CATEGORY C-B I
IRH-HXIB-07 NOZ TO SHELL UT NRI 2
IRH-HXIB-07 INNER RADIUS UT NRI ASME CATEGORY C-C I
RH02-1003V MT NRI 2
RH03-1138X MT NRI 3
RH13-1009X MT NRI 4
RH13-1154S MT NRI 5
RH53-1012X MT NRI ASME CATEGORY C-G I
ILP-PU-01 PT NRI 2
ILP-PU-02 PT NRI 3
ILP-PU-03 PT NRI
TABLE B AUGMENTED ISI INSPECTIONS AISI CATEGORY TYPE IA ITEM #
I 2
3 4
5 6
7 8
9 ITEM DESCRIPTION LP-1001-02 MS-1046-14 RH-1001-02 RH-1002-02 RH-1002-05 RH-1002-06 RH-1031-27 RH-1031-29 RH-1031-31 EXAM TYPE RESULT UT UT UT UT UT UT UT UT UT NRI NRI NRI NRI NRI NRI GEOMETRY NRI NRI AISI CATEGORY BWRVIP-75 IGSCC ITEM #
ITEM DESCRIPTION EXAM TYPE RESULT I
2 3
4 5
6 7
8 RH-1005-26 RH-1031-27 RH-1031-29 RH-1031-31 RR-1001-14A RR-1006-07 RR-1006-08 RR-1006-09 UT/PT UT UT UT UT/PT UT/PT UT/PT UT/PT NRI GEOMETRY NRI NRI NRI NRI NRI NRI AISI CATEGORY VESSEL INTERNALS 2
3 4
5 6
7 8
9 10 I11 12 STEAM DRYER VT-I & 3 STEAM SEPARATOR VT-3 CORE SPRAY PIPING UT/EVT-I CORE SPRAY SPARGERS VT-1 & 3 CORE SPRAY SPARGER BRACKETS EVT-I JET PUMP BEAMS UT JET PUMP ASSY. WELDS EVT-I, VT-I & VT-3 FEEDWATER SPARGER BRACKETS EVT-I LPCI COUPLINGS EVT-I, VT-I & VT-3 ACCESSIBLE JET PUMP # 18 & #20 ADAPTER WELDS VT-I & VT-3 SUPPORT PLATE TO SHROUD CYLINDER WELD EVT-1 SHROUD HEAD BOLTS VT-3 SEE REPORT PG. 5 NRI, SEE REPORT PG. 6 SEE REPORT PAGE 7 BWRVIP-18 NRI, BWRVIP-18 NRI, BWRVIP-18 SEE REPORT PG. 6 BWRVIP-41 SEE REPORT PG. 6 BWRVIP-41 NRI, BWRVIP-48 NRI, BWRVIP-42 NRI NRI NRI AISI CATEGORY MISC.
ITEM #
1 2
3 ITEM DESCRIPTION RPV STUDS (1-68)
LCS-I -NI I INSIDE SURFACES OF RPV TOP HEAD EXAM TYPE RESULT UT PT NRI, SEE REPORT PG. 3 NRI, BWRVIP-27 VT-3 NRI
TABLE C ASME CODE SECTION XI COMPONENT & SUPPORT EXAMINATIONS ASME CLASS I ITEM #
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 ITEM DESCRIPTION FW02-1004V FW02-1012V FW02-1054X FW02-1157X FW02-1158X FW02-1170S HP02-1003C LP02-1002X MSOO-1021X MSOO-1028V MSOO-1038X MSOO-1039X MSOO-1051X MSOO-1056V MS01-1005V MS01-1006V MS06-IOOIC RH03-151 IX RH04-1503S RH03-1505C RH04-1509V RH04-1512V RH40-1523X RH53-lOOIC RH53-1553X RI24-1500C RROO-1038V RROO-1068V RR16-1006C RR28-1006V RR28-1017X RTO1-1082X RTOI-1083X RTOI-109OG EXAM TYPE RESULT VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 NRI NRI NRI NRI LOOSE NUT, ADJUSTED NRI NRI NRI NRI TOOL MARKS, ACCEPTED NRI NRI NRI NRI NRI NRI NRI NRI NRI LOOSE NUT, ADJUSTED NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI ASME CLASS 2 2
3 4
5 6
7 8
9 10 I11 12 13 14 15 16 17 18 HG05-1033X HG05-1034G HG06-109OX MS01-1023C MSO1-1291X MSO1-1351X MS28-1014X RHO1-1401X RH02-1002V RH02-1007V RH03-1013V RH13-1009X RH34-1031V RH40-1020V RH53-IOIOV RH53-1012X RH53-1013X RH59-1055G VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI
TABLE D ASME CODE SECTION Xi PRESSURE TESTING ITEM #
ITEM DESCRIPTION EXAM TYPE RESULT I
l-CM-03 VT-2 NRI 2
1-CM-05 VT-2 NRI 3
I-ES-OI VT-2 NRI 4
1 -FC-09 VT-2 NRI 5
I-FC-1O VT-2 NRI 6
1-FW-O1 VT-2 NRI 7
1-HG-09 VT-2 NRI 8
1 -JN-09 VT-2 NRI 9
I-IN-10 VT-2 NRI 10 I-IN-I I VT-2 NRI 11 I-IN-12 VT-2 NRI 12 1-IN-13 VT-2 NRI 13 1-IN-14 VT-2 NRI 14 I-IN-15 VT-2 NRI 15 I-MC-O1 VT-2 NRI 16 I-MS-OI VT-2 NRI 17 I-NB-O1 VT-2 NRI 18 I -PC-02 VT-2 NRI 19 I-RC-PB VT-2 PACKING & GASKET LEAKS 20 I-RR-OI VT-2 NRI 21 1-RR-02 VT-2 NRI 22 1-RR-04 VT-2 NRI 23 I-RR-05 VT-2 NRI 24 1-RR-06 VT-2 NRI 25 1-RR-08 VT-2 NRI 26 I-SA-OI VT-2 NRI 27 I-VP-01 VT-2 NRI 28 I-VP-02 VT-2 NRI 29 I-VQ-02 VT-2 NRI 30 1-VQ-03 VT-2 NRI 31 1-VQ-04 VT-2 NRI 32 1-VQ-05 VT-2 NRI 33 I-IVR-0I VT-2 NRI
TABLE E REPAIR/REPLACEMENT ACTIVITIES CLASS-I WORK PACKAGE NUM BER DESCRIPTION
- 1.
374030 Replace Inboard FW Check Valve & Piping Spool
- 2.
426545 Replace RR Control Valve Stud & Nut
- 3.
455051 Replace Bonnet & Disc on RR Isolation Valve
- 4.
458344 Replace Control Rod Drive & Capscrews
- 5.
465508 Replace Explosive Valve after Firing
- 6.
470338 Replace RR Drain Valves & Piping Sub-Assembly
- 7.
488846 Replace NB Snubber
- 8.
508311 Replace Main Steam SRV with Rebuilt Spare
- 9.
508312 Replace Main Steam SRV with Rebuilt Spare
- 10.
508313 Replace Main Steam SRV with Rebuilt Spare
- 11.
508314 Replace Main Steam SRV with Rebuilt Spare
- 12.
508315 Replace Main Steam SRV with Rebuilt Spare 13 508317 Replace Main Steam SRV with Rebuilt Spare
- 14.
508318 Replace Main Steam SRV with Rebuilt Spare
- 15.
515531 Replace Disc on Main Steam Isolation Valve
- 16.
515532 Replace Disc on Main Steam Isolation Valve
- 17.
530219 Replace Control Rod Drive & Capscrews
- 18.
556289 Replace Outboard MS Drain Isolation Valve
- 19.
557248 Replace Control Rod Drive & Capscrews
- 20.
557249 Replace Control Rod Drive & Capscrews
- 21.
557250 Replace Control Rod Drive & Capscrews
- 22.
557251 Replace Control Rod Drive & Capscrews
- 23.
557252 Replace Control Rod Drive & Capscrews
- 24.
557253 Replace Control Rod Drive & Capscrews
- 25.
557254 Replace Control Rod Drive & Capscrews
- 26.
557255 Replace Control Rod Drive & Capscrews
- 27.
557256 Replace Control Rod Drive & Capscrews
- 28.
557257 Replace Control Rod Drive & Capscrews
- 29.
557258 Replace Control Rod Drive & Capscrews
- 30.
557259 Replace Control Rod Drive & Capscrews
- 31.
557260 Replace Control Rod Drive & Capscrews
- 32.
557261 Replace Control Rod Drive & Capscrews
- 33.
557262 Replace Control Rod Drive & Capscrews
- 34.
557263 Replace Control Rod Drive & Capscrews
- 35.
557264 Replace Control Rod Drive & Capscrews
- 36.
557265 Replace Control Rod Drive & Capscrews
- 37.
557266 Replace Control Rod Drive & Capscrews
- 38.
557267 Replace Control Rod Drive & Capscrews
- 39.
557268 Replace Control Rod Drive & Capscrews
- 40.
557269 Replace Control Rod Drive & Capscrews
- 41.
557270 Replace Control Rod Drive & Capscrews
- 42.
557271 Replace Control Rod Drive & Capscrews
- 43.
557272 Replace Control Rod Drive & Capscrews
- 44.
557273 Replace Control Rod Drive & Capscrews
- 45.
557274 Replace Control Rod Drive & Capscrews
- 46.
557275 Replace Control Rod Drive & Capscrews
- 47.
557289 Replace Snubber Load Pin & Piping Flange Studs & Nuts
- 48.
- 49.
- 50.
659252 Refurbish Spare MSIV Disc Assembly
- 51.
659253 Refurbish Spare MSIV Disc Assembly
- 52.
660755 Replace SC Valve Disc
- 53.
96094699 Replace RH Vent Valves
- 54.
96094702 Replace RH Vent Valves
TABLE E (CONT'D)
REPAIR/REPLACEMENT ACTIVITIES CLASS-1 WORK PACKAGE NUM1BER DESCRIPTION
- 55.
- 56.
99047389 Fabricate RR Piping Sub-Assembly
- 57.
99156492 Replace Inboard FW Check Valve & Piping Spool CLASS-2 WORK PACKAGE NUMBER DESCRIPTION
- 1. 448209 Repair Piping Spool by Welding
- 2.
436382 Replace RI Rupture Discs
- 3. 455046 Replace RI Valve
- 4.
465398 Repair Heat Exchanger by Plugging Tubes
- 5. 465766 Repair Valve by Metal Removal
- 6.
488858 Replace Snubber Load Pin
- 7. 518067 Replace Load Stud Nut
- 8. 541754 Repair Valve by Metal Removal
- 9. 541755 Repair Valve by Metal Removal
- 10. 644421 Replace RI Orifice I. 658780 Repair Strut
- 12. 98107466 Replace RH Snubber
- 13. 99008865 Replace HP Vent Valves
- 14. 99202246 Replace Load Stud
- 15. 99214139 Repair Valve by Metal Removal
ATTACHMENT 1 NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION
UKMIN INIS-1 UMNEMKS REPUKI FOK ENSLEKVICE IiN1LC1 IUNh As required by the Provisions of the ASME Code Rules
- 1. Owner Exelon Generation Company (EGC), LLC, 200 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner)
- 2. Plant LaSalle County Station, 2601 North 21st Road Marseilles, IL 61341-9757 (Name and Address of Owner)
- 3. Plant Unit One
- 4. Owner Certificate of Authorization (if required)
N/A
- 5. Commercial Service Date 01/01/84
- 6. National Board Number for Unit 21086
- 7. Components Inspected Component or Manufacturer Manufacturer State or National Appurtenance Or Installer or Installer Province No.
Board No.
Serial No.
Reactor Pressure Combustion IB13-D003 B-24318 21086 Vessel Engineering Reactor Recirculation General Electric N/A N/A N/A Company Nuclear Boiler & CM B.F. Shaw N/A N/A N/A Systems Residual Heat B.F. Shaw N/A N/A N/A Removal Feedwater, FC & VQ B.F. Shaw N/A N/A N/A Systems High Pressure Core B.F. Shaw N/A N/A N/A Spray Low Pressure Core B.F. Shaw N/A N/A N/A Spray Main Steam, IN & PC GE/B.F. Shaw N/A N/A N/A RD, RI & RT Systems B.F. Shaw N/A N/A N/A ES, MC, SA & WR B.F. Shaw N/A N/A N/A Systems SC, HG & VP B.F. Shaw N/A N/A N/A Systems N4ote: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8Y2 in. x I 1 /2 in., (2) information n items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at he top of this form.
FORM NIS-1 (Back)
- 8. Examination Dates:
02/04/02 to 2/12/04
- 9. Inspection Period Identification:
3rd Period - From 10/12/03 to 10/11/2006
- 10. Inspection Interval Identification:
2nd Interval - From 11/23/94 to 10/1 1/2006
- 11. Applicable Edition of Section Xi
- 12. Date/Revision of Inspection Plan:
1989/1998*
Addenda N/A 11/20/2002 Rev.4
- 13. Abstract of Examination and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Summara Report for item 13.
- 14. Abstract of Results of Examinations and Tests. See Summary Report for item 14.
- 15. Abstract of Corrective Measures. See Summary Report for item 15.
- Via Relief Request CR-32, the 1998 Edition of the ASME Code, Section Xi applies to CISI We certify that a) the statement made in this report are correct, b) the examinations and tests meet Inspection Plan as required by the ASME Code, Section Xi, and c) corrective measures taken conform to the ASME Code,Section XI.
Certificate of Authorization No. (if applicable)
N/A Expiration Date N/A Date May 7 20 04 Signed Exelon Generation Company, LLC By Owner CERTIFICATE OF INSERVICE INSPECTION 1, the under signed, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois And employed by HSB-CT of Hartford, Connecticut Have inspected the components described in the Owner's Report during the period 02/04/2002 To 2/12/2004
, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owvner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Ii k 4
Commissions IL. 1927 pOector's Signature National Board, State, Province, and Endorsements Date 20 04
ATTACHMENT 2 NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Comoanv (EGCI LLC (Name) 200 Exelon Way, Kenneth Square, PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Date 04102104 Sheet 1
of I
Unit I
W.O. #374030 Repair Organization, P.O. No., Job No., etc.
Name 2601 N. 215t Rd. Marseilles. II. 61341 Address 3.
Work Performed h-Il&hal al 1
~nnr (Name)
Mechanical Maintenance Type Code Symbol Stamp NIA Authorization No.
5.
6.
(Address)
Identification of System (B21) Feedwater (a) I Appilcable Construction Code Sect III 19 71 Edition W72 Addenda, Code Cases N62-7 (b)
Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89_*
No Ad. Code Cases N-416-2 Identification of Components Repaired or Replaced, and Replacement Components Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
(1) 24" Tilting Anchor N/A 1B21-F010B Replaced N/A Disc Check Valve Daring (1) 24" Swing Flowserve AU578 NIA 1B21-FOIOB 2003 Replacement NIA Check Valve C_
Receipt # 94256 1
1 (1) 24" O.D. x Consolidated Ht. # T3955, N/A Receipt # 85972 2003 Replacement N/A 12"L Pipe Power S/N RP-2035 Extension SupplyI 7.
8.
9.
Description of Work Class 1 Replacement. * = Per N-5 Code Data Reoort on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I I Pneumatic 1I Normal Operating Pressure I X I Other Visual Pressure 1030/1045 osl Test Temp. Amblent Deg. F Remarks Replaced tilting disc Inboard feedwater check valve with a swina tvoe check valve per Engineering (Applicable Manufacturer's Data Report to be Attached )
Change EC# 51394 due to chronic leak rate failure.
- New valve Is Class I ASME Section III 1989 No Addenda reconciled to the oriolnal construction code. Appllcable Construction Code for ololna Is ASME Sect. III 1974 Ed.
No Addenda.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xi.
(repair or repla Type Code Symbol Stamp NONE
_--conforms to the rules cement)
Certificate of ihorization No.
NIA Expiration Signed '
ISI Coordinator I
Owner or Owner's Designee, Title Date NIA Date y//2
. 2004 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler fnsp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LI-R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
lecwt/f2.
-Commissions IL 1927 Inspegms Signature National Board, State, Province, and Endorsements Date_
2004
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*
As Required by the Provisions of the ASME Code, Section 111, Div. t Pg.1 of 2
- 1.
Manufactured and certified by Fiowserve Corporation, 1900 S. Saunders Street Raleieh. NC 27603 (Nane SW Address d N CerWkcae Hddo
- 2.
Manufactured for Business Senices Co.. P. 0. Box 805388, Chicaeo. IL 60680 (gm ondAderessof P Aner)
- 3.
Location of Installation Exelon Generation Co.. L2Salie Nuclear Station. 2601 N. 21" Road. Marsellles. IL 61341 (Name and Address)
- 4.
Model No.. Series No.. or Type 1500# Swing Check Drawing WN..0125773*
Rey H
CRN
- 5.
ASME Code. Section ill. Division 1:
1989 No-N/A (e5iion)
(addeda dale)
(dass) tCode Case no.)
- 6.
Pump or Valve Valve Nominal Inlet Size 24" OuUet Size 24"
-nh)
-cJ
- 7.
Material:
Body SA216, WCB Bonnet SA105 Disk SA105 Boiting SA1 93, Gr. B7 (a)
(b)
(c)
(d)
(e)
CertL Nat l Body Bonnet Disk Holder's Board Serial Serial Serial Serial No.
No.
No.
No.
No.
AUT578 N/A E7818-1 L3226-1 L,3226-3 S..emna.nomto In.or
- o.
.its s.ice
.rrwig mab usdpoie 1 ieI -1xi' omto nies1truh4o
'Supplemnentalinformafon in fomrn oflists, sketchesordeawMngsmraybe usedprovided (1)sizeIs 8-1J2 xli1; (2id'Aformallon In Items 1through4con this Data Report is Indluded on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
k
FORM NPV-1 (Back-Pg. 2 of 2) 94256 Certificate Holder's Serial No. AU578
- 8.
Design conditions 2600 (pressure) psi 575 (temperature) 0F or valve pressure class 1500
- 9.
Cold working pressure 3705 psi at 100*F
- 10.
Hydrostatic test 5575 psi.
Disk Differential test pressure 4076 psi.
- 11.
Remarks:
Nuclear swing check valve. Stud material heat code Q318; Nut material SA194, Gr. 7, heat code 12750; Gasket Retainer material SA516, Gr. 70, heat T4794/5B-2; Hinge Pin Cover material SA105, heat 77296-2,3; Drain Connection material SA105, heat 77297-2; Drain Pipe material SA106, Gr. B, heat 708474-24; Drain Cap material SAJOS. heat 2854ANF-2.
- Pipe extension as shown on drawing was not welded to this valve.
S. 0. 23028 CERTIFICATION OF DESIGN Design specification certified by James T. Conner P.E. State MD Reg. no.
23476 Design Report certified by Ronald S. Farrell P.E. State NC Reg. no.
028656 I
CERTIFICATE OF COMPLIANCE We certify that the statements made' In this report are correct' and that this pump, or valve,
.conforms to the rules of construction of: the ASME Code for NUdear Power Plant Components.
Section 11I. Div. I.,
4 TN Certificiate of Authorization No.
N-1562 Expires
_ 1o7-Nov. 26, 2003 Date lloo
- 3 Name Flowserve Ciirporatlon Signed.
(N Certitate Hode&)
(Asred Represamttvte)
CERTIFICATE OF INSPECTION
- 1. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT of Hartford Connecticut
- tiaveinspecttd Ut: pusup.
vdllve:described In thisData Repart
-j
/
, anda7ae-that.Io the-besonknowiedge and belief, the Certificate Holder has constructed this pump, or valve, In accordance with ASME Code, Section lil. Div. 1.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the component described In this Data Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Date II
/ I l/03
/
X Ad "n
A, 61"":'ff Signed
_Commissions t0L. / 'i
/
( Insped&r)
(Nanl Sd, State, Prgv. and No.)
Perl%
12017 N;@
gi~.
M.
lll,'
S.
SI ic~~;h 1
T d
Uft.Mport =*he t oo the Rdd br ed..;M PO abid..d'1 eow ss@.,-..........
Ii,;O.
i '
.L _6 d&
aiid:
Pi:oi Nnd VpjisW; Usl hno p '-""-'A.........................
wo 1-tltD W.
po of rrl la d w b bbeWef # Co
=sW xofis ptx in m~ane i
dvXA Code, Soctbi 111, DivUW.oi..
F"i
.d t
tmshlb Fadio I*^"
hn S
in uwfr riprord o
" daf
.="
Al Xd to fw d
%s h h 4a-
.h t O*K ohso'bM
)r
~
,WW f
ast go lpt.AUt-2.J70@30 of WM
...!ST 1
eDMW c wOdwN.
S. 200-Ks:.
CPS' i
14:
0OAR.EVIW M6AW
. fzs ~._*-1 tl. i I ~.. _,.
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1.
Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Date 03/01/04 Sheet 1
of I
Unit 1 2.
Name 2601 N. 21t Rd. Marseilles. ff. 61341 (Address)
W.O. # 426545-01 Repair Organization, P.O. No., Job No., etc.
3.
Work Perfonmed by Irtn~{T-alo o
Can Mechanical Maintenance (Name)
Mechanical Maintenance (Address) s~~~n2A n---<
6:P+-
AP-lI+n Type Code Symbol Stamp NIA Authorization No.
N/A Expiration Date N/A 4.
5.
6.
(a) Appiicable Construction CodeASME Sect. ill 19 71 Editlon W72 Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad. Code Cases None Identification of Comoonents Reoalred or Reolaced. and Replacement Comoonents Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
(1) Valve Body to ITT N/A IB33-F060B Replaced N/A Bonnet Stud Hammel-(1) Valve Body to NOVA Ht. Trace Code N/A Receipt # 75777 2002 Replacement N/A Bonnet Stud C952 (1) Valve Body to ITT N/A 1B33F0601B Replaced N/A Bonnet Stud Nut Hammel-(1) Valve Body to NOVA Ht. Trace Code N/A Receipt # 77035 2002 Replacement N/A Bonnet Stud Nut E510
_II_
- 7.
Description of Work: Class I Replacement. * = Per N-5 Code Data Reoort on file at LaSalle County Station.
- 8.
Tests Conducted:
Hydrostatic lo Pneumatic I I Normal Operating Pressurel I Other Visual Pressure 1040 psl Test Temp._165 Deg. F
- 9.
Remarks: One (1) stud and one (1) nut replaced due to binding of nut on stud.
Nw (Appilcable Manufacturer's Data Report to be Attached )
New Belleville washers Inserted underneath body to bonnet nuts ver Engineering Chance EC# 338802.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl.
(repair or replacement)
Type Code Symbol Stamp NONE Certificate of Authorization No.
Slagn nr/0
.09t f~6-L" N/A
_Expiration Date N/A IRI Conrdinatnr Date 03 /-Zz
. 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insy. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to 1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and, corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
- 2A S
da-Commissions IL 1927 Inst.9tor's Signature National Board, State, Province, and Endorsements Date 3?-/
2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1.
Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way, Kenneth Sauare. PA., 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address)
Date 03/16/04 2.
Sheet I
of I
Unit 1 W.O. # 455051 Repair Organization, P.O. No., Job No., etc.
Type Code Symbol Stamp NIA Authorization No.
N/A Expiration Date N/A 3.
Work Performed by_
Mechanical Maintenance (Name)
Mechanical Maintenance (Address) 4.
5.
6.
Identification of System (B33) Reactor Recirculation (a) Applicable Construction Code,_ASME Sect. III 19 71 Edition NO Addenda, Code Cases None (b)
Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989
.No Ad. Code Cases None Identifleatinn nf Cnmnennntsq Renalrad nr Rentacd-and RPnt~acemnt Cmnnnonnts Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
(1)-24" dia. Valve Atwood &
NIA 1B33-F023A Replaced N/A Bonnet Cover Morrill (1)-24" dia. Valve Weir HT: 97134 N/A CID 45765 2003 Replacement N/A Bonnet Cover Valves SIN H487 Receipt # 91876 (1)-24" dla. Valve Atwood &
N/A 1B33-F023A Replaced N/A Disc Morrill (1)-24" dia. Valve Atwood &
HT. 9777 N/A CID 45817 2002 Replacement N/A Disc Morrill S/N H492 Receipt # 78087 (1)-24" dia. Valve Weir HT: 97134 N/A CID 45765 2003 Repaired N/A Bonnet Cover Valves SIN H487 Receipt # 91876 (1)-24" dia. Valve Atwood &
HT. 9777 N/A CID 45817 2002 Repaired N/A Disc Morr SIN H492 Receipt # 78087 8.
9.
Description of Work: Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted:
Hydrostatic II Pneumatic I _I Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp.J165 Deg. F Remarks: Replaced and Installed a new design disc. auldes and stem to eliminate galling tendency of the old (Appiicable Manufacturer's Data Report to be Attached )
Internal components. In addition. a new bonnet cover was Installed to allow for the use of a single stage packing design.
- Machining was performed on the new bonnet cover and disc for fit up purposes. This design chanae Is per enalneerina change EC # 49631.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and these Repalr & Replacement conforms to the rules of the ASME Code, Section Xl.
(repair or replacement)
Type Code Symbol Stamp NONE Certifi of A rizatlon No.
NIA Expiration Date N/A Signed e8 ISI Coordinator Date eX.5,6 9*
. 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insy. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to L1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
-4 Commissions IL 1927 Ins r's Signature National Board, State, Province, and Endorsements Date
_3-__
___-2004
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
=
9 1 8 7 6 As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2
- 1. Manufactured and certified by Weir Valves & Controls, USA Inc.. 285 Canal Street Salem, MA 01970 iname and address of NPT Certficate Holder)
- 2. Manufactured for Exelon. 2601 N 21st Rd., Marseilles, IL 61341-9757 (name and address of Purchaser)
- 3. Location of installation LaSalle County Station, 2601 N 21"t Road - RR #1, Marseilles. IL 61341-9757 Iname and address)
- 4. Type:
(drawng no.)
S. ASME Code,Section III, Division 1:
(marl spe-. no.)
sb ngth)
(CRM i(a, buA N/A 1971
- No I
(eodbon)
- 6. Fabricated In accordance with Const. Spec. (Div. 2 only) isadends dats)
(class)
NIA (no.)
Revision N/A Date (coo. Gase no.)
N/A
- 7. Remarks:
Cust. Item 01 WVC Item 10, Cover Weldment, A&M P/N 42115-806-9051-000 QLA (WVC S.O. 67842) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III.1971 Edition No Addenda.
- 8. Nom. Thickness (In.)
2.250 Min. design thickness (n.)
0.76 Dia. ID (ft & In.)
N/A
- 9. When appricable Certificate Holders Data Reports are attached for each item of this report:
Length overafl (ft& in.)
N/A Part or Appurrtenance Serial Number HT: 97134 S/N H487 National Board No.
In Numerical Order N/A Part or Appurtenance Serial Number National Board No.
In Numerical Order (1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25) i (26)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
(34)
(35)
(36)
(37)
(38)
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
PIAu110faa 1::!!:'
4z::/-.Z fLLOeIL
-mdkA4a-I.
I/ANXI
_RQ f-AIIF Af mit-N' I
l
.9.
.9.
4.
4.
4-K..) Design pressure 1250 psi. Temp.
575 F. Hydro. test pressure N/A twhen oppi~cabl.)
At temp. F Supplemental Information In the formn of lists, sketches, or drawings may be used provided (1) size s xB.
x 11 t2) Information In Items 2 and 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top o* this form.
112188)
This form (Eo0040) may be obtained from the Order Dept. ASME. 22 Law Drive, Box 2300. Fairfield, NJ 07007.2300.
Reprint (7191)
918 76 FORM N-2 (Back-Pg. 2 of 2)
Certificate Holders' Serial Nos.
HT: 97134 S/N H487 through N/A Design specifications certified by Design report
- certified by CERTIFICATION OF DESIGN Joseph C. Major (when applicable)
N/A P.E. State
.CA Reg. no.
14695 N/A P.E. State N/A Reg. no.
(when applicable)
CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these)
Cover Weldment NPT Certificate of Authorization No.
Date 7/
/
1 N2607 Expires 6-13-04 Name Weir Valves & Controls, USA Inc.
(NPT corg Hoiisf Signed Io 1l Sp41ve CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MA And employed by H.S.B.C.T.
of Hartford, CT have Inspected these Items described In this Data Report on 7.L'/-03 and state that to the st of my knowledge and belget the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.
',./sIgning this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described In this Data Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or loss of any kind arising from or connected with this Inspection.
Date 7-,411, Signed
(
4 Commissions 064 /4tC
-Ad.40-Id (aubonUd M.spect=
(Mrl rd. (md. Endamernis n
ad etaut V pmv. ad no.]
The following items attached to Cover Weldment:
Pipe Boss - SA479-316 - HT: 720036 SST 316 Pipe - SA312-316 - HT: D852458 Elbow-SA403-316-HT: 19513-TR: MJ
¢:,,
I
- r "
.u A.'
0 :;.r I:
,..4.
>,.,.t
, 1 a'
- N;4,.1 4108dhsto o -
dL 4 TylW
. *3244 5AIM Codi3Sason W. Dkioan :
1071 S. FsMbokd in VO~sewU CoiL Spos (Dv., 2 uMy
- 7.
.u c~ bm{.AAM ~io 10 0w
- *~w
-am, A,,,,
thi.
,_..ua IL NOm.Tbick"WOO) 37/a1 MvidhsNUd4 V ).
t
. 3.33' I.I, 9
"M
~u upploiM.. CaulM.~ to~u' Dds R4elsf or.
Aw 'WeSam eU..pot A
rAppawmmc-Pu tPrppsmW
'i..b i.S Order It-it LM 37 r
II WA
_I, VC0
.. NW
.Sml~w rdmr -
n..I.
M)
(31)
(M5 (36)
(37)
(35)
(30)
(43)
N ZA JA
-'I I
- y II
I t%
wi o.
2
'S.
D U
0*60 ebomi go sO DqtA.
AMnL rDZft kak NPbW.K NJ VlW
' ' @,*l -
1
-- g.'g
?'
-'i t ~
~ ~ ~ ~ ~ ~ -
S i....
~,\\St.
.sP s.,.;
A t~itmi}'Plt/,
/
't}
a+-,
.,wf;,*
i ti,5 *oe* t
- ~ ~
~
~
~
~
~
~
~
~
I j
t S
>1i4V g
t, 5
{'
.3;,,
'i~e by' f'
In;4 Uft. to C60id i#W-d Me
0 77-:
budaqtdlo2 or
- )N c Lntwn-
- !~~~~~~~~~~~~~~~~~~
>qEt rDt
+
s-e3^lcojiO5@
i--
- --f q~Wg w~l~t0l>-let69BL^@?tAfp4rlib*
/kX~s>S8<S-WX*,£;oM^-#>"Sbl**<L v~c~a S
X
!Z
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1.
Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21 Rd. Marseilles. 1i. 61341 (Address)
Date 02125104 Sheet I
of I
Unit I W.O. # A45rA4-01 I
2.
Repair Organization, P.O. No., Job No., etc.
3.
Work Performed by_
Mechanical Maintenance (Name)
Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No.
5.
(Address)
Identification of System (RD) Control Rod Drive (a) Applicable Construction Code ASME Sect III 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilzed for Repairs or Replacements-1 989 No Ad, Code Cases None Identification of Comoonents Renalred or Renlaced. and Renlacement Comnonents 6.
Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identlfilcation Built Replaced, or Stamped No.
Replacement (Yes or No)
CRD Assembly G.E.
Al 056 N/A 10-51 Replaced N/A CRD Assembly G.E.
A984 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 10-51 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 90242 2003 Replacement N/A
_ _ _ _C l192 0
7.
8.
9.
Description of Work Class I Replacement. * = Per N-5 Code Data Revort on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I I Pneumatic II Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp.
165 Deg. F Remarks CRD SN# A984 was refurbished with documentation orovided under Quality Recelt # 95580 and (Applicable Manufacturer's Data Report to be Attached )
Installed as a replacement for SN# Al056 under work order #458344-01.
- = Replacement CRD Code of Construction Is ASME Section 111.1971 Ed. S73 & W73 Ad. Reconciled to the orlginal ver PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction is ASME Section lii. Class 1.1986 Ed. No Ad. Reconciled to the orialnal Code of Construction ner PTE M91-007-0320-01 on file at LaSalle Station.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI.
(repair or replacement)
Type Code Symbol Stamp NONE Certificate of Authorization No.
N/A Expiration Date N/A Signed C-,
L 6
ISI Coordinator Date 0& /°*
/
. 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of.Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have inspected the components described in this Owner's Report during the period LIRO9 to LR-110 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
1 i
24/
"2Z 4.L..
Commissions IL 1927 Inspers Signature National Board, State, Province, and Endorsements Date 2 3 A
2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1.
2.
Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21' Rd. Marseilles. II. 61341 (Address)
Date Sheet 1
of I
Unit 1 Wnfi
- 4550 03102104 Repair Organization, P.O. No., Job No., etc.
3.
Work Performed by_
Mechanical Maintenance (Name)
Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No.
N1A Expiration Date NIA (Address) 4.
S.
Identification of System (C41) Standby Liquid Control (a) Applicable Construction CodeASME Sect. III 19 77 Edition S77 Addenda, Code Cases None (b)
Applicable Edition of Section Xi Utilized for Repairs or Replacements-1989, No Ad. Code Cases None Identification of Components Repaired or Replaced, and Replacement Components
- 7.
Description of Work: Class I Reolacement * = Per N-5 Code Data Report on file at LaSalle County Station.
- 8.
Tests Conducted:
Hydrostatic IIJ Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 122011050 osl Test Temp. Ambient Deg. F
- 9.
Remarks: Replacement components were constructed to ASME Sect Ill. Class 1 1977 Ed S77 Addenda.
(Applicable Manufacturer's Data Report to be Attached)
Replacement reconciled per PTE 88-161 on tile at LaSalle Station.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Reolacement conforms to the rules of the ASME Code, Section Xi.
(repair or replacement)
Type Code Symbol Stamp NONE Certificate of Authorization No.
NIA Expiration Date NIA Signed ISICoordinator Date d
2004 Owiner or Owner's Designee, Title
/
CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issuedby the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to 1IRI10O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner forany personal Injury or property damage or a loss of any kind arjIng from or connected with this Inspection.
/IIiA Z
Commissions IL 1927 InspeS5r's Signature National Board, State, Province, and Endorsements Date _
2004
Va J
-FORU LI IHOUMW.-$)^T*% Ow"'Mis Al=!
Code.
-..77777QLjjj P I dp,'
copy Ucs" of boodWm initial
%"Id a""
Ann PM&"
MW bdif -
k soowm
.AV
-welid 6, oL mim mi, PM or 0101 -
Obdud flood to an
-vi -!;1
- S W
I T
gas
?77 Mx 11 41 T1 CIO%
(Ila
-Y
OVS:
Its fie IM i,:7 t T L!
Z:" r Im t2s) t)%M lp law Brooks in fo 2:&i'T'A 3 on ab
- b. an %M of 16;i 0, mm' ir
=W
=a PwAftd C23 an Is 8% x I U ta bdwwApftn
- 0 dwat la an&% I
-low W abomb, a mon sop'st"
- Wm
'-Z
CBICI OF:O l^
.4 apeifcadom by St.
CA FbiA,.
g M
Cloo 5,....... -1 bw WV
',4 no.
i j
. -; MS.N r
",'f;.
.odon
_w Mms of sopmom4 OWSS ClmOia ILkm
,~.
o_*
v~er D
t ss_
gr r
XA'
- 1.
f
- 8.
- }
O.E.
,
- oom..
Itr some u*
w so
$"d=
40 ylow; 4p
-WW
.awa
- "GMv-i
- , __ *@t_
l
^w*-
t
<- -SR!a"..
d rqwS Mil
~
E>
s^,w:.#X.ro the.t>
b4. ~~~~~~~~~~~~~~~~~~sae rfm:f
,aaQ.
XX,;: -.*~4 4
96¢t ~
~
~
~
~ ~ ~ ~w w tir >_ ;^^
s i:G.
b.....................................
W
.¢.zor a*
a".
_wa.-w@^ r w 0.
MOCO 01
& tl'-
^<'.i ^ii X
pop toW -;'i; so 'i 'b
';vi-011" t OVAL W vA 9w0 a"
v FORM
- 1. Manufactured and certified by
- 2. Manufactured for
- 3. Location of installation
- 4. Type:
N20000, Rev. G ldrawing no.)
I N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
- Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production 725 56 0 0 7 Pg. 1 of 2 IST-Conax Nuclear. 402 Sonwil Drive. Cheektowaoa. NY 14225 nanete and address of NPT Certificate Holder)
Exelon Generating Company. LLC ename and address of Purchase)
LaSalle Generating Station. Marseilles, IL 61341i.9757 Iname end address 75 KSI SA479 304SST N/A 2001 (mat'l spec no.)
Itenile strength)
ICRN)
(year WHO
- 5. ASME Code,Section III, Division 1:
77 S77 1
NIA (edlion)
(addenda date)
(dssa (Code Cae no.)
- 6. Fabricated In accordance with Const. Spec. (Div. 2 only)
NIA Revision Date 7 rno_
- 7. Remarks:
Trigger Body Subassembly for explosive actuated valve replacement kit for standby liquid control system.
Para. NB-2121 (b) Is apmlicable to ram. Press Fit/Seal on.328 &.4375 diameters. Overall subassembly lenoth Is 2.65.
Pressure Test at 2800 psi for 10 minutes.
- 8. Nom. thickness (in.) See Remarks Min. design thickness (in.) See Remarks Dia. ID (ft & In.) See Remarks Length overall (ft & In.)
See Remarks
- 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report:
I
-I 1)
(2)
(3)
(4)
(5) 16)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18) 119)
(20) 121)
(22)
(23)
(24)
(25)
Part or Appurtenance Serial Number National Board No.
. In Numerical Order 6184 6184 6185 6185
.9 4.
4.
a-
. Part or Appurtenance National Serial Number Board No.
In Numerical Order (26)
(27) _
(28)
(29)
(30)
(31) __
132)
(33)
(34)
(35)
( 3 6 )
(37)
( 3 8 )
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47) _
(48)
(49)
(50)
.9
.9 4.
4.
4.
4.
_ _ _ _ _ 1 K u I
V Design pressure 1500 osi. 'Temp.
150 IF.
Hydro. test pressure I See Remarks at temp. 'F (when appticable)
- Supplemental information In the form of lists, sketches, or drawings may be used provided 11) size Is 8Ys x 11, 12) Information In Items 2 and 3 on this Data Report Is Included on each sheet, (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
FORM N-2 (Back - Pg. 2 of 2.
Certificate Holder's Serial Nos.
6184 through 6185 CERTIFICATION OF DESIGN Design specifications certified by George I. Skoda P.E. State CA
'Reg. no.
15847 lwhan appkacble Design report certified by Francis J. Domino P.E. State NY Reg. no.
36832 (when pi flCINe2
.4 CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these)
Trigger Body Assemblies conforms to theirules of construction of the ASME Code, Section 1I1, Division 1.
NPT Certificate of Authorization No.
N. '850 Expires September 2. 2004 Dateo Name IST Conax Nuclear Signed 1-C4 INPT CItIicats HokdW)
(authorzzd ralwesantat")
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Hartford Steam Boiler Inspection & Insurance Company of Hartford. CT have inspected these hems described In this Data Report on,e1..5i
, and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in-accordance with the ASME Code, Section 1II, Division 1. Each part listed has been authorized for stamping on the date shown above.
Ry signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment scribed In this Data Report. Furthermore, neither the Inspector nor his employer-shall be liable In any manner for any personal Injury or
. t-perty damage or loss of any kind arising from or connected with this Inspection.
tDate /0--s i
SignCormmissions NB 10964AN NY 5057 l
p(Natl Od. Ond. endorsements) and state oa pro,. and no.1
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address
- 2.
Plant LaSalle County Nuclear Station Dfa mm3v2nlA Name 2601 N. 21t Rd. Marseilles. II. 61341 Sheet 1
of 2
Unit 1
W.O. # 470338 Repair Organization, P.O. No., Job No., etc.
Type Code Symbol Stamp NIA Authorization No.
N/A Expiration Date NIA Address 3.
WnrAt 0-rtn-e N..
MAh-16-,
-in U.Sna.
n vwurv (Name)
Mechanical Maintenance (Address) 4.
5.
Identification of System (RR) Reactor Recirculation (a) Applicable Construction Code..
IlL 19 74 Edition No Addenda, Code Cases None (b)
Appiicable Edition of SecUon Xl Utilzed for Repairs or Replacements-19 89. N Code CasesN-416-2 Idanfifilnainn of Cnnmnonnts Ranalred or Renlacedd and Rnlarermant Comnonants Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
(1)-1.5" dia. Piping Exelon UTC 2638812 N/A 1B33-FO51AIF052A 2002 Replacement N/A Sub-Assy (W.O. 99047389)
Mechanical PSA 37751 N/A IRRI7-1001S Replaced N/A Snubber (PSA-114)
Hydraulic Lisega 036157301038 NWA IRR17-1001S 2003 Replacement NWA Snubber (Type 301 856RE2)
_Receipt
. 137N)
Receipt # A99-00234 (1) Rear Bracket Comer &
UTC 2687858 WA Catalog ID # 646644 2004 Replacement N/A for PSA 114 Lada (Fig. 776) 8.
9.
Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I I. Pneumatic I __I Normal Operating Pressure I X I Other Visual Pressure 1040 sl Test Temp. 165 Dog. F Remarks Field Installation of newly fabricated Piolne Sub-assembly consisting of two (2) new 1.5" dia. Yarwav (Applicable Manufacturer's Data Report to be Attached )
stainless steel alobe valves-and-assocIated-Dolnai (Ref. Fab, W.O. 99047389 EC # 51221 (DCP99001491. In additinn W.O. 470338 reolaces a Mechanical Snubberwith a Hydraulic Snubber for IRR17-10018 and modified clamo/boltina hardware for supoorts IRR17-IO1S. 1RR17-1002X and 1REI?- 1001C. All these rePlacements are Per engineering change EC# 334780. Orlainal code of construction for supports is ANSI B31.7 1969 Ed. No Add.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code,Section XI.
(repair or replai Type Code Symbol Stamp NONE Certificate of Authorization No.
NIA Expiration Date Slannadc62 Z
t ISI Coordinator Date conforms to the rules cement)
NIA 3 /
.2004 Owner or Owner's Designee, Title 7,-,
CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIRO9 to LIRIO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty
- expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
iu/
?,Lt Commissions IL 1927 o'
Signature NationalBoard, State, Province, and Endorsements Date V
?.Y Jz 2004
FORM NIS-2 SUPPLEMENTAL SHEET
- 1.
Owner:
Exelon Generation Company (EGC) LLC Sheet_
200 Exelon Way, Kenneth Square, Date PA., 19348 Unit
- 2.
Plant:
LaSalle County Station 2601 N. 21st. Rd.
Marseilles, Illinois 61341
- 3.
Work Performed by: Mechanical Maint.
Type C Name Author Mechanical Maintenance Fynlraf 2
of 2
03/23/04 I
W.O. # 470338 P. O. No., WR No., etc.
ode Symbol Stamp N/A ization No.
N/A ion Date N/A
___r1 I-4.
5a.
5b.
6.
Address Identification of System (RR) Reactor Recirculation Applicable Construction Code Sect. III 1974 Edition No Addenda Applicable Edition of Section Xl utilized 89 Edition None Addenda Identification of Components Repaired or Replaced and Replacement Components.
Name of Name of Manufacturer National Other Year
- Repaired, ASME Component Manufacturer Serial No.
Board Identification Built Replaced Code No.
or Stamped Replacement (Yes or No)
(1) 318" N/A UTC 2022574 N/A Catalog ID #
1998 Replacement N/A Thk. Flat 514295 Bar A-36 (1) Pipe NIA IRR17-1002X Replaced N/A Clamp Assy (1) Pipe Anvil UTC 266898 N/A Catalog ID #
2003 Replacement N/A Clamp Intl.
16604 Assy Receipt #
88976 (1) Pipe N/A IRE17-.IOOIC Replaced N/A Clamp Assy (1) Pipe Anvil UTC 2619719 N/A Catalog ID #
2001 Replacement N/A Clamp Intl 1225982 Assy Receipt #
70788
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Date 03103/04 Sheet I
of 1
Unit 1 2.
Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address)
W.O. # 488846-01 Repair Organization, P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Autkhrwiz1nan Nn MIA 3.
Work Performed by-Mechanical Maintenance (Name)
Mechanical Maintenance (Address)
Expiration Date N/A 4.
5.
A Identification of System (NB) Nuclear Boller (a) Applicable Construction Code ANSI B31.7 19 69 Edition NO Addenda, Code Cases None (b)
Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989, No Ad, Code Cases None Idpnfifirnfinn nf Comnnnnnts Rpnalrpd nr Rpnlate-d, and Renpae-ment Comnonents Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
Mechanical PSA NIA I NB13-IOIS Replaced N/A Snubber (PSA-1)
Mechanical PSA 309 N-A INB13-1001S 1999 Replacement N/A Snubber (PSA-1)
UTC 2017098 8.
9.
Description of Work: Class I Reolacement of Mechanical Snubber.
Tests Conducted:
Hydrostatic I I Pneumatic I I Normal Operating Pressure I-I Other Visual Pressure psi Test Temp.__Deg. F Remarks: I = Per Orialnal Deslan Svecificatlon J-2530.
(Applicable Manufacturers Data Report to be Attached )
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this of the ASME Code, Section Xl.
Type Code Symbol Stamp NONE Replacement conforms (repair or replacement) to the rules Certificate of Autrization No.
Signed L11A Frrtl at x,"
uApIIaQJS*
VaLt N/A ISI Coordinator Date
° 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
AtI A
a Commissions IL 1927 inspqeor's Signature National Board, State, Province, and Endorsements Date 3 2004 I
I r
i w
vt,
- ,.-tZ;,-,^,
- ~
f
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21' Rd. Marseilles. II. 61341 Address Date 02/2A104
>.W vvs Sheet 1
of I
Unit I
W.O. #508311-01 Repair Organization, P.O. No., Job No., etc.
3.
Work Performed I..
gamhtlo & - - - - - -
Wy MlVIW40l ll I WIOI lmenanceII (Name)
Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A 4.
S.
(Address)
Identification of System (MS) Main Steam (a) Applicable Construction Code Sect il 19 71 Editlon S172 Addenda, Code Cases 1567 and 1711 (b)
Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89.
No Ad, Code Cases NO Identification of Comoonents Renalred or Replaced, and Renlacement Comoonents 6.
Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
Safety Relief Valve AG N63790-05-0009 N/A 1B21-FO13P Replaced N/A Crosby Safety Relief Valve AG N63790-00-0109 N/A 1B21-FO13P Replacement N/A Crosby or N63790 Receipt #94701 0109(Modifed)_
Disc Insert N93185-38-0099 N/A Replaced N/A Disc Insert AG N97499-43-0098 N/A Receipt #94701 2003 Replacement N/A
~C rosby
_ j_
7.
8.
9.
Description of Work Class I Reoair & Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 Psi Test Temp._165 Deg. F Remarks Valve SN# N63790-05-0109 was refurbished at Wvle Labs with documentation provided under Quality (Applicable Manufacturer's Data Report to be Attached )
Recelot #94701 and installed as areolacement for SN# N63790-05-0009 under work order# 508311. All bolting 4.tn.
Aeervntvvita wmn A.-n lirr w
-n narrmr
.1n ni 1 Ila h.#
n
- 1.
.1-1
.11
- ** Reclacement SRV Serial No. was modified due to the Installation of a new flexl-disc seat deslan.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xl.
(repair or repla Type Code Symbol Stamp NONE conforms to the rules icement)
Certificate of Authorization No.
Slgned e
d) klsA tr 4I.. *%-&
MM LwAFIIOLIVII 040 N/A ISI Coordinator Date Z73/0
-.5-/
, 2004 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to 1R.10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
' cCommissions IL 1927 Ins"sq r's Signature National Board, State, Province, and Endorsements Date
.3 _e 2004
Q.C.-392 9~7flI*Sheet 1 of 2 FORM N-2 CERTIFICATE HOLDERS'. DATA REPORT FOR IDENTICAL NUCLEAR PARTS ANIW APPURTENANCES*
As required bv the Provisions of the ASME Code;Section III, Division 1 - Not to Exceed One Day's Production
- 1. Manufactured and certified by Anderson Greenwood Crosby, 43 Kendrick St., Wrentham, MA 02093 (Narde and Address of N Certificate Holder)
- 2. Manufactured for EXELON GENERATION (Name and Address of Purchaser or Owner)
- 3. Location of Installation LASALLE COUNTY STATION (Name and Address)
- 4. Type DS-C-63790-5 REV.A ASME SA637 GR.718 185,000 2003 (drawing no.)
(mat'l. spec. no.)
(tensile strength)
(CRN)
(year built)
- 5. ASME Code,Section III, Division 1:
1971 SUMMER 1972 1
(edition)
(addenda date)
(class)
(Code Case No.)
- 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
Revision.
Date (no.)
- 7. Remarks
- 8. Nom. thickness (in.)
Min. design thickness (in.)
Dia. ID (ft & in.)
Length overall (ft & in.)
- 9. When applicable, Certificate Holders' data reports are attached for each item of this report.
Part or Appurteiance Serial Number l)
.'N97499-3810060
.N97499-38-0061
- 13) N9749943-0098 (4) N97499-43-0099 (5) N9749943-0101 (6) N97499-43-0102 (7) N9749943-0103 (8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
' National Board No.
,.in Numerical Order (26)
(27).
_(28)
(29)
(30)
(31)
(32)
- (33)
(34)
- (35)_
(36)_
(37)_-
(38)
(39)_
(40)_
(41)
(42)
(43)
(44)
(45)
(46)
(47)_
(48)
(49)
(50)
Part or Appurtenance Serial Number
~
National Board No.
in Numerical Order
- e.
7 I
k-:.
- 10. q>gn pressure psi.
Temp.
°- F Hydro. test pressure 2370 at temp. 70 0
(when applicable)
' Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 1-1/2 x 11. (2) information in items 2 and 3 on this Data Report s included on each sheet. (3) each sheet is numbered and the number Jshcets is recorded at the lop of this form.
This form (E00040) may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300, Fairfield. NJ 07007-2300 I
t Z-1 f-U;S; 1 4: ;:0 WO
- L I I '
LVUUV IV 'I I
Form N-2 (Back)
~
llIIV ' VT I V I '
Ut U 70 1 Q.C-392 Sheet 2 of 2 Certificate Holder's Serial No. N97499-38-0060 CERTIFICATE OF COMPLIANCE We certify thethe statements made in this report are correct and that this (these)
Disc inserts conforms to the rules of construction of the ASME Code, Section 1II, Division 1.
NPT Certifcpte of Authorization No.
N-1877 Expires Sep. 30, 2004 Anderson Greenwood Crosby pate
_-03 Signed Wrentbmn, MA by 0 (=. //
(NPT Certificate Holder)
(Authorized 1presentative)
.1*
CE-T-ICR TE OFINSPE'CTJONv 1, the uuidersigned, holding a valid commission Issued ihe National Board of Boiler and Pessre Vessl Inspectc, and the'State or Provmce of Massachusetts and employ, d by actorv Mutual Insurauce Co.
of Yohnston. Rhode Island have inspected these items described in this Data Report on 20 o3 and state that to thi st of my kowledge ad belief, the ertificate Holder has fabricated thesh parts or appurtenances in accordance w-2h tihe ASME Codc, Section m, Division 1. Bach part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the eq(iipment described in this Data Report. Furermore, Acither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss 4f any kind arlig from or connected with this inspection.
Commissions.
1W 4
/ w (Nat'l. BU. (inc. endorsements) and state or prov. and no.)
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles, II. 61341 Address nDte 02/27/0A go..
v_,
f v_
Sheet 1
of 1
Unit 1 '
Wl #508nR312 Repair Organization, P.O. No., Job No., etc.
3.
Work Performed L..
-J
_2-2e loll UJ MIU110a11d I
M41KLIece (Name)
Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A (Address) 4.
S.
Identification of System (MS) Main Steam (a) Applicable Construction Code Sectli 19 71 Edition S172 Addenda, Code Cases 1567 and 1711 (b)
Applicable Edition of Section Xi Utilized for Repairs or Replacements-19 89, No Ad, Code Cases NO Identification of Components Renaired or Renlaced. and Renlacement Comnonents 6.
Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Bulit Replaced, or Stamped No.
Replacement (Yes or No)
Safety Relief Valve AG N63790-00-0017 N/A 1B21-FO13V Replaced N/A C rosby Safety Relief Valve AG N63790-00-0102 N/A 1B21-F013V Replacement N/A Crosby or N63790 Receipt # 94701 0102(Modified)_
Disc Insert N93185-46-0174 N/A Replaced N/A Disc Insert AG N97499-43-0103 N/A Receipt #94701 2003 Replacement N/A C ro sby 7.
8.
9.
Description of Work Class 1 Repair & Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted:
Hydrostatic lI Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osi Test Temp. 165 Deg. F Remarks Valve SN# N63790-05-0102 was refurbished at Wyle Labs with documentation orovided under Quality (Applicable Manufacturer's Data Report to be Attached )
Recelot # 94701 and Installed as a replacement for SN# N63790-00-0017 under work order # 508312. All bolting materials were reused. A visual examination VT-1 was performed on all Class I Inlet bolting.
- Renlacement SRV Serial No. was modified due to the Installation of a new flex[-disc seat desian.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xl.
(repair or repla Type Code Symbol Stamp NONE conforms to the rules icement)
Certificate of Authorization No.
Signed
, t,
KIIA Frlrtln at rIlA flpLraIIun 1.
N/A ISI Coordinator Date
° 3/°;,5 /
. 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to LR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the Inspector nor his employer makes any warranty,expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
7//
"Z 1AZ Commissions IL 1927 Inspector's ignature National Board, State, Province, and Endorsements Date __
2004
Q.C.-392 Sheet 1 of 2 FORM N-2 CERTIFICATE HOLDERS'. DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As required by the Provisions of the ASME Code: Section III, Division I - Not to Exceed One Day's Production
- 1. Manufactured and certified by Anderson Greenwood Crosby, 43 Kendrick St., Wrentham, MA 02093 (Nanie and Address of N Certificate Holder)
- 2. Manufactured for.
EXELON GENERATION e
(Name and Address of Purchaser or Owner)
- 3. Location of Installation LASALLE COUNTY STATION (Name and Address)
- 4. Type DS-C-63790-5 REV.A ASME SA637 GR.718 185,000 2003 (drawing no.)
(mat'l. spec. no.)
(tensile strength)
(CRN)
(year built)
- 5. ASME Code, Section HII, Division 1:
1971 SUMMER 1972 1
(edition)
(addenda date)
(class)
(Code Case No.)
- 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
Revision.
Date (no.)
- 7. Remarks
- 8. Nom. thickness (in.)
Min. design thickness (in.)
Dia. ID (ft & in.)
Length overall (ft & in.)
- 9. When applicable, Certificate Holders' data reports are attached for each item of this report.
Part or Appurtenance' Serial Number (1
I N97499-38-0060 v 1) N97499-38-0061
. 3) N97499-43-0098 (4) N97499-43-0099 (5) N97499-43-0101 (6) N97499-43-0102 (7) d N97499-43-0103 (8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
National
.Board No.
ii Numerical Order E. -
(26)
(27.
-(28)
.(29)
(30)
(31)
. (32)
- (33)
(34)_
_(35)
(36)
- (37)-
(38)
(39)
(40)
(41)
(43)
(44)
(45)
(46)
(47)
(48)
- (49)
(50)
Part or Appurtenance Serial Number I...
I National Board.No.,.,...
in Numerc'-al Or-d~e'r!'
I
~
i III
'I ' '
I I'
J
- 0. D-;gn pressure psi.
Temp.
° F
Hydro. test pressure 2370 at temp. 70 K >
(when applicable)
Supplemental information in dhe form of lists, sketches, or drawings may be used provided (1) size is 5-1/2 x ll. (2) information in items 2 and 3 on this Data Report included on each sheet, (3) each sheet is numbered and the number olshicts is recorded at the top of this form.
This form (E00040) may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300, Fairfield. NJ 07007-2300
- 1) F
1 t&
I /
U;:5; 14: ;:.30 L
IVV I
1 U
I V
I111 VI I Fon N-2 (Back)
Certificate Holder's Serial No. N97499-38-0060 11 v '
v I v I.
VI V 59_11 7o /
Q.C-_392 Sheet 2 of 2 CERTIF2ICATE O COML CE We certify that the statements made in thts report are correct and that this (these)
Disc Inserts conforms to the rules of construction of the ASME Code, Section ILI, Division 1.
NPT Cerrfi~cte of Authonzation No.
N-1877 EBpires Sep. 30, 2004 Anderson Greenwood Crosby Date OZ )-DX R-0 Signed Wrenina MA by -r
- i-1/
(NPT Certificate Holder)
(Authorized l r
e
)
CER 7FICAWTE OF INSPEC-.ON I,the uadrgudholdiniga i valid commission ised by the National Board of Boiler and Pessre Vessel pdectcrs az4 the State or Pmvmce of
-hassichusetts and employ d by Factory Mutual Insurance Co.
have isnpected these items described In this Data Report on
- &9ca
,[
,P 20 O3 and stato that to th best of my kowledge and belief, the('efrifltc older ha fabicated parts or ipurtenances in accordance vlth the ASME Codc, Section m, Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the Lupector nor his employer makes any waranty. expressed or implied, concerning the eqhpment descrbed m this Data ReporL F O
=e, pcidter Ie Inspcor nor his employer aha be liable in any marmer for any personal iqjury or property damage or loss, f any 7nd arising from or connected with this inspection.
Date
-? 9 P
, 20 0.3.
Signed
£2-62 ~
(Authc rized Inpector)
Commissions
,4Z.4 -/ /'P (Nat'l. Bd. (incL endorsemen) and state or prov. and no.) f
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Companv (EGC) LLC Date 02127104 (Name) 200 Exelon Wav. Kenneth Souare. PA.. 19348
_ _ _ _ A _. _.. _ w e _ _ _ _ _ _. _ l.. _ w. _ _. _
Address
- 2.
Plant LaSalle Countv Nuclear Station Sheet 1
of 2
Unit I
W.O. #508313-01 Repair Organization, P.O. No., Job No., etc.
Name 2601 N. 21t Rd. Marseilles. II. 61341 Address 3.
Work Performed h-.'
MnX-a6-1-l Mn - -
(Name)
Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No.
5.
(Address)
Identification of System (MS) Main Steam (a) Applicable Construction Code Sect iii 19 71 Edition 572 Addenda, Code Cases 1567 and 1711 (b)
Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89.
No Ad, Code Cases N.496.1 Identification of Components Reoalred or Replaced. and Replacement Components 6.
Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
Safety Relief Valve AG N63790-00-0067 N/A 1121-FO13M Replaced NIA Crosby Safety Relief Valve AG N63790O0-0080 NIA 1B21-FO13M Replacement NIA Crosby or N63790 Receipt # 94701 0080(Modlfied)_
Disc Insert N93185-31-0022 N/A Replaced NIA Disc Insert AG N97499-38-0061 NIA Receipt #94701 2003 Replacement NIA Crosby 7.
8.
9.
Description of Work Class I Regair & Reniacement. * = Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I]I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 nsl Test Temp._165 Deg. F Remarks Valve SN# N63790-05-0080 was refurbished at Wvle Labs with documentation provided under Quality (Applicable Manufacturer's Data Report to be Attached )
Recelpt # 94701 and Installed as a replacementforSN# N63790-00-0067 underwork order# 508313. Forthe remainder of the ReDaired. Replaced and Replacement Items. see Form NIS-2 Supplemental Sheet on Paaes 2 of 2.
Reolacement SRV Serial No. was modified due to the Installation of a new flexi-disc seat deslan.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and these Repair and Replacement conforms to the rules of the ASME Code, Section Xl.
(repair or replacement)
Type Code Symbol Stamp NONE Certificate of Authorization No.
Signed C
S*
MIlA FC-lfntl-onto NIA rank c^"laLlull 1.
ISI Coordinator Date
./
. 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L1 R09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Impiled, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arlsi from or connected with this Inspection.
/
"?Z./4 ZLAI&
Commissions IL 1927 Inspector Signature National Board, State, Province, and Endorsements Date
_3 - R 1 2004
- 1.
Owner:
- 2.
Plant:
FORM NIS-2 SUPPLEMENTAL SHEET Exelon Generation Company (EGC) LLC Sheet 2
of 2
200 Exelon Way, Kenneth Square, Date 02127/04 PA., 19348 Unit 1-LaSalle County Station 2601 N. 21 st. Rd.
Marseilles, Illinois 61341 W.O. # 508313-01
- 3.
Work Performed by: Mechanical Maint.
Name Mechanical Maintenance P.O. No., WR No., etc.
Type Code Symbol Stamp N/A Authorization No.
NIA Expiration Date N/A 4.
5a.
5b.
6.
Address Identification of System MS (Main Steam)
Applicable Construction Code 71 Edition S72 Addenda Applicable Edition of Section Xi utilized 89 Edition None Addenda Identification of Components Repaired or Replaced and Replacement Components.
Name of Name of Manufacturer National Other Year
- Repaired, ASME Component Manufacturer Serial No.
Board Identification Built Replaced Code No.
or Stamped Replacement (Yes or No)
Valve Body AG Crosby N93183 N/A Receipt #
Repaired N/A 0007 94701 (1) Hell-Coil AG Crosby N97823-48 NIA Receipt #
2003 Repaired N/A Insert 94701 (Outlet)
(1) Heli-Coll AG Crosby N97823-49 NIA Receipt #
2003 Repaired N/A Insert 94701 (Outlet)
(2) Inlet NOVA N/A Replaced N/A Tension Nuts (2) Inlet NOVA Ht. Code N/A Receipt #
2001 Replacement NIA Tension C491 69812 Nuts
Q.C.-392
.-94.7 ()
Sheet 1 of 2 Ku FORM N-2 CERTlFICATE HOLDERS'. DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As required by the Provisions of the ASME Code; Section 111, Division I - Not to Exceed One Day's Production
- 1. Manufactured and certified by Anderson Greenwood Crosby, 43 Kendrick St., Wrentham, MA 02093 (Nanie and Address of N Certificate Holder)
- 2. Manufactured for EXELON GENERATION (Name and Address of Purchaser or Owner)
- 3. Location of Installation LASALLE COUNTY STATION (Name and Address)
- 4. Type DS-C-63790-5 REV.A ASME SA637 GR.718 185,000 2003 (drawing no.)
(mat'. spec. no.)
(tensile itrength)
(CRN)
(year built)
- 5. ASME Code,Section III, Division 1:
1971 SUMMER 1972 1
(edition)
(addenda date)
(class)
(Code Case No.)
- 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
Revision.
Date (no.)
- 7. Remarks
- 8. Nom. thickness (in.)
Min. design thickness (in.) *-
Dia. ID (ft & in.)
Length overall (ft & in.)
- 9. When applicable, Certificate Holders' data reports are attached for each item of this report.
Part or. Appurtenance :
- ~~~~ l Serial Number; -
I
- 1) '. N97499-38-0060 v/jjt'N97499-38-0061 l at) N97499-43-0098 (4) N97499-43-099 (5) N97499-430101 (6) N97499-43-0102 (7) N97499-43-0103 (8)
(9)
(10)
(11)-
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)_
(20)
(21)
(22)
(23)
(24)
(25)
National
..-:Board No.
i
- -i Numerical Order inNm a
_I (2
(2 (31 (3:
4(3)
(31 (34
- (35 (36 (37 (38.'
(3 9:
(40J (41)
(42)
(43) 46) 48) 49)_
50)_
6)_
Part or Appurtenance
'C,; iSerial Number
- ,t,..
, I
- t.
-,: :7.,
I 7).
- 8) 9)
2) 3)
1)
- )
I1)
)-
)_
I-I-
National Board No..
in Numerical Order
-I.
kN
" I i
I (I
l-
- 0. T gn pressure psi.
Temp.
° F Hydro. test pressure 2370 at temp. 70 0 F (when applicable)
Supplemental information in the form of lists, sketches, or drawings may be used provided (I) size is 8-.12 x 11. (2) information in items 2 and 3 on this Data Report included on each slheet, (3) each sileet is numbered and the number o7shcets is recorded at the top of this form.
This form (E00040) may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300. Fairficd, NJ 07007-2300
-J
1 2-1 fUom; 14 Back)
Li LI -I ILUVVV-I V ' VI I II
-W Form N-2 (13ack)
.I Iv
- r I
v VIt
,9 70 /
Q.C--392 Sheet 2 of 2 Certificate Holder's Serial No. NW7499-38-0060 CERTIFICATE OF COMPLANCE We certify that the statements made in this report are correct and that this (these)
Disc Inserts conforms to the rules of construction of the ASME Code,Section II, Division 1.
NPT CertificPtc of Authorization No.
N-IM877 Expres Sep. 30, 2004 Anderson Greenwood Crosby Date ZC-O 0,3 Signed W
_ MA by r
=.1 (N Certificate Holder)
(Authorized presetauive)
- . 'WP Ar S
-l fl
.i f
-i Wm
.,-- U.
- 1, the uiErsigned,-holding a valid commission issued by the National Board of Boiler and Prssure Vessel inspecto and l ie State or Pro4mte of Massachusetts and employed ly
- *_.acto=
Mutual Insrac Co.
of
. Johnston. Rhode Island he inspeced these items described In this Data Report-on I 1
' r a
cP U
,20 O3 and state that to thi best of my knowledge and belief, the Certificate *older has fabricated ik parts or appurtenances In accordance u ilie ASME Code, Section mL Divislon 1. Each par listed has been authorized for stamping on the date shown above.
By signing tibs certificate, neither the Inspector nor his emnployeK makes any warranty. expressed or implied, cncernng the cqlnpmen descried im this Data Report Fuxthetmorl, Acither tue Ispecor nor his employer shuall be liable in any mainner for any personal injury or property damage or 1os5 4f any kid arismg from or connected with this inspection.
l Commissions V-4-1, wp at'l. Bd. (ncl. CEdorseMe=ts) and State or prov. and no.)
FORM NiS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner_ Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21t Rd. Marseilles. ii. 61341 Address a2te 02127/0lA a.9 vats fv_
Sheet 1
of 1
Unit I
W. #508R31A4-01 Repair Organization, P.O. No., Job No., etc.
3.
Work Perfnrmed, bw Mechanicr Mlintlniann.-A Kiev..\\., -
J (Name)
Mechanical Maintenance Type Code Symbol Stamp N/A Auithnrlatinn No MIA Exnlratlon Date NIA
-r.. -.. _
4.
5.
(Address)
Identification of System (MS) Main Steam (a) Applicable Construction Code Sect Lil 19 71 EditIon S/72 Addenda, Code Cases 1567 and 1711 (b)
Applicable Edition of Section Xl Utilized for RepaIrs or Replacements-19]89_,
No Ad, Code Cases NO Identification of Comoonents Renaired or Renlaced. and Renlacement Comnonents 6.
Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
Safety Relief Valve AG N63790-00-0076 N/A 1B21-F0135 Replaced N/A C rosby_
Safety Relief Valve AG N63790-00-0064 NA I1B21-F0135 Replacement NIA Crosby or N63790 Receipt #94701 0064(Modifiedge Disc Insert N93185-41-0125 N/A Replaced NIA Disc Insert AG N97499-43-0102 N/A Receipt #94701 2003 Replacement NIA C ro sb y 7.
8.
9.
Description of Work Class I Repair & Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I I
Pneumatic I I Normal Operating Pressure IX I Other Visual Pressure 1040 esi Test Temp._165 Deg. F Remarks Valve SN# N63790-05-0064 was refurbished at Wvle Labs with documentation Provided under Quality (Applicable Manufacturer's Data Report to be Attached )
Recelot # 94701 and Installed as a replacement for SN# N63790-00-0076 under work order # $08314. All bolting materials were reused. A visual examination VT-1 was performed on all Class I Inlet bolting.
- - Reolacement SRV Serial No. was modified due to the Installation of a new flexl-disc seat desian.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xi.
(repair or repla Type Code Symbol Stamp NONE conforms to the rules cement)
Certificate of Authorization No.
Signed 6
N/A Expiration Date N/A ISI Coordinator Date..
/°5f
. 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIRiO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Commissions IL 1927 Inspec s Signature National Board, State, Province, and Endorsements Date J3-o-- 2004
Q.C.-392
--9 7 01 Sheet 1 of 2 FORM N-2 CERTIFCATE HOLDERS'. DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As required bv the Provisions of the ASME Code;Section III, Division I - Not to Exceed One Dav's Production
- 1. Manufactured and certified by Anderson Greenwood Crosby, 43 Kendrick St., Wrentham, MA 02093 (Nanle and Address of N Certificate Holder)
- 2. Manufactilred for EXELON GENERATION (Name and Address of Purchaser or Owner)
- 3. Location of Installation LASALLE COUNTY STATION (Name and Address)
- 4. Type DS-C-63790-5 REV.A ASME SA637 GR.718 185,000 2003 (drawing no.)
(mat'l. spec. no.)
(tensile strength)
(CRN)
(year built)
- 5. ASME Code,Section III, Division 1:
1971 SUMMER 1972 1
(edition)
(addenda date)
(class)
(Code Case No.)
- 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
Revision.
Date (no.)
- 7. Remarks
- 8. Nom. thickness (in.)
Min. design thickness (in.)
Dia. ID (ft & in.)
Length overall (ft & in.)
- 9. When applicable, Certificate Holders' data reports are attached for each item of this report.
Part or App Serial N
- 1) N97499-38-0060 l \\
N97499-38-0061 l.3) N97499-43-0098 f
(4) N97499-43-0099 (5) N97499-43-0101 (6) N97499-43-0102 (7) N97499-43-0103 (8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25) lurteriance' dumber:i; National
-Board No.
in'Numerical Order, (27).
(28)
.(29)
(30)
- (31)
(32)_
- (33)_
(34)_
_(35)_
(36)
. (37).
(38)_
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)-
(47)
(48)
(49)
(50)
Part or Appurtenance
-. :Serial Number -
National
.- :Board No' in Numerical Order I
I I -
4 I
IjII4
- 10. t>gn pressure psi.
Temp.
°~ F Hydro. test pressure 2370 at temp. 70 0 F (when applicable)
' Supplementil information in the form of lists, sketches, or drawings may be used provided (l) size is S-1/2 x It. (2) information in items 2 and 3 onthis Data Report S included on each sheet. (3) each sheet is numbered and the number osheets is recorded at the top of this form.
This form (E00040) may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300, Fairfield, NJ 07007.2300 II
112z-l f-
- 1; 1 4 "It LI*I*II L VJ I UII III N
E orm N-2 (Back)
E'.
5/
70o1 Q.C.-392 Sheet 2 of 2 Certificate Holder's Serial No. N974S9-38-OQ6O CERTIFICATE OF COMPLIANCE We certify that the statements made m this report are correct and that this (these)
Disc Inserts conforms to the rules of construction of the ASME Code,Section III, Division 1.
NPT Cerificate of Authonzation No.
N-1877 ExpIres Sep. 30, 2004 Anderson Greenwood Crosby Date i
B -0$
Signed Wre by F). t.
//
(NPT Certificate Holder)
(Authormied =presentative)
I CEREIFICAYER OF INSPECTION I, the undesigndholding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State o'r Provmce of Massachusetts and employed by
_&actorv Mutual Insurance Co.
of Yohnston. Rhode Island have inspected these items described in this Data Report on
- 1
- c. ci., 20 o3 and state that to thi best of my knowledge and belief, the Ctertificate Holder has fabricated thes parts or appurtenances in accordance w% the ASMto Code, Section m, Division I. Each pant listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the Ibspector nor his employer makes any warranty, epressed or implied, concerning the eqinpment described il this Data ReporL Furlhiricore, jcither the Inspector nor his employer sba)) be liable in any manner for any personal injury or property damage or loss of any knd arising from or connected with this irspection.
.K Date 2
9O
, 20 0 _;.
Signed
$2 2
t (Authoized Inspector)
Commissions (Ntat. Bd. (incl. endorsements) and state or prov. and no.)
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl
- 1.
Owner Exelon Generation Companv tEGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21g Rd. Marseilles. II. 61341 Address Date (19I27MA a-9 vw^^tv_
Sheet 1
of I
Unit I
W.O. #508315-01 Repair Organization, P.O. No., Job No., etc.
3.
4.
5.
6.
Work Performed by ITAXI1
-+^
AsCROA-Mechanical Maintenance (Name)
Mechanical Maintenance (Address)
^
Iffi icIA 22A1-Type Code Symbol Stamp NIA Authorization No.
N/A Expiration Date NIA 1UVlIemllai;dL1IU10VI U!ybLVl IM;>
malini.amIdll (a) Applicable Construction Code Sect iii 19 71 Edition SI72 Addenda, Code Cases 1567 and 1711 (b)
Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89, No Ad, Code Cases NO Identification of Components Renalred or Renlaced. and Renlacement Comnonents Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
Safety Relief Valve AG N63790-00-0008 NIA 1B21-FO13K Replaced N/A C ro sby Safety Relief Valve AG N63790-00-0011 NA 1B21-F013K Replacement NIA Crosby or N63790 Receipt # 94701 0011(Modlfled)'
Disc Insert N93185-65-0282 NIA Replaced N/A Disc Insert AG N97499-38-0060 NIA Receipt #94701 2003 Replacement NIA C ro sb y 7.
8.
9.
Description of Work Class I Renalr & Replacement. * = Per N-5 Code Data Renort on file at LaSalle County Station, Tests Conducted:
Hydrostatic I _J Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 nsl Test Temp._165 Deg. F Remarks Valve SN# N63790-05-0011 was refurbished at Wvle Labs with documentation orovided under Quality (Applicable Manufacturer's Data Report to be Attached )
Recelot # 94701 and Installed as a replacement for SN# N63790-00-0008 under work order # 508315. All bolting materials were reused. A visual examination VT-1 was performed on all Class I Inlet bolting.
Replacement SRV Serial No. was modified due to the Installation of a new flexi-disc seat design.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code,Section XI.
(repair or repli Type Code Symbol Stamp NONE
-conforms to the rules icement)
Certificate of A orization No.
NIA Expiration Signed G
ISI Coordinator I
Owner or Owner's Designee, Title Date NIA Date a 2
. 2004 CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issuedby the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to LIRID and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
LJA 7A/ -Commissions IL 1927 Inspecto SIgnature National Board, State, Province, and Endorsements Date q
2004
Q.C.-392
_-o fn1 Sheet i of 2 FORM N-2 CERT1F1CATE HOLDERS' DATA REPORT FOR IDEN77CAL NUCLEAR PARTS ANI) APPURTENANCES*
As required by the Provisions of the ASME Code; Section In, Division I - Not to Exceed One Day's Production
- 1. Manufactured and certified by Anderson Greenwood.Crosby, 43 Kendrick St., Wrentham, MA 02093 (Nanle and Address of N Certificate Holder)
- 2. Manufactured for.
EXELON GENERATION (Name and Address of Purchaser or Owner)
- 3. Location of Installation LASALLE COUNTY STATION (Name and Address)
- 4. Type DS-C-63790-5 REV.A ASME SA637 GR.718 185,000 2003 (drawing no.)
(mat'l. spec. no.)
(tensile sitrength)
(CRN)
(year built)
- 5. ASME Code, Section mII, Division 1:
1971 SUMMER 1972 1
(edition)
(addenda date)
(class)
(Code Case No.)
- 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
Revision.
Date
- (no.)
- 7. Remauls
- 8. Nom. thickness (in.)
Min. design thickness (in.)
Dia. ID (ft & in.)
Length overall (ft & in.)
- 9. When applicable, Certificate Holders' data reports are attached for each item of this report.
Part or Appurtenance
-Serial Number.
- 1) ;.N9i499q-38!6'
.) N97499-38.0061 t
- t3) N97499-43-0098 (4). N97499-43.0099 (5) N97499-43:0101-I (6) N97499-43.0102 (7) N97499-43-0103 (8)
(9)
(I10) t1)
(12)
(13)
(14)
(16)
(18)
(19)'
(20 (21)
(22)
(23)
(24)
(25)
Niational Part or Appurtenance Board Vo.....
- Serial Number, in Numercal Orderr
( 2 1 )...
. (28).
(30)
(31)
(32)
- .(33)______
- .(34)
(35)
(36)
(37).
(3 8)
A _
_(_
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
National' Board No.
- , Numerical Order
. I (4
(47
( 8 J
0.I' tn pressure psi.
Temp.
e F Hydro. testpressure 2370 at temp. 70 K..J (when applicable)
- uppIcffUtl information in the form of lists, sketches, or drnwings nay be used proYided (1) sze is -1m2 x it. (2) inforrmtion in items 2 and 3 on this Dars Repon
- ,rcuded on esch sheet, (3) each sheet is nunbered and the number olshets is recorded at the top of this lorm.
This form (EO0040) may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300, Fairficld. NJ 07007-2300 o F
lZ-l IUt-UIJ 1 4 :.
I; UVF I
-I VUV I U ' Vk I I
- II Form N-2 (B3ack) 1lU* u..rl u'-
,4
- u
.00,
/
Q.C.-39%
Sheet 2 of Ceraificate Holder's Serial No. N97499-38-0060 CERTIFIC3A T OF DESIGN Design Tpecifications cerified by C.T NIEH P.E. State CA Reg. no. 15587 (vvhe apl~icable)
Design report* certified by P.E. State _
Reg. no.
(when applicable)
CERTMICAE OF COMPTIAAtCE We certify tat the statements made l ntls report are coect and that thns (these)
Disc Inserts conforms to the rules of construction of the ASME Code,Section II, Division 1.
NPT Cerfificpte of AutlonzionNo.
N-187 Expires Sep. 30, 2004 Amderson Greenwood Crosby lpate ZO -Are-O8-3 Signed WMA My (NPT Cefcate Holder)
(Authorize
.t Ir Z,..
-CERTIFACAT OF NPC1QY;
.v..
X I, zhf Under3Jgned, holding a valid commimssion lssied by theNa6onaL Board of Boiler and Pressure Vessel hspetib :
theState or Provnce of Massachusetts'
- and ewplooyaby Pactory Mutual Imsurmee Co-
- of Johnston. Rlodee Island
-sfpeic d these items described In this Datz Report on ;
o, 20 03 and state dht to th6 best of my koowlecdge and belief, the (weficate Holder has fabricated parts or app4ur CCS in accordace wilh ile AShE Code,Section II Division 1. Each part lied has becen athioized for stamping on the date shown above.
By signing this certificate, nelther the Inspector nor his employer makes any warray. epressed or implied, concring the eqinpment descrzbed imk this Data Report Fwrtcia ore., Aelher the Iwpeor nor his employer 81311 be liable in any mamner for any personal injury or property damage or loss qf any and Arin from or connected with this inpection.
. 1...f
. 0. "
I Sij I
Commissions -
(Ntl. BI. (indL. endaen) amd MWe or prov. and no.)
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Companvy EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Date 02/27/04 Name 2601 N. 216 Rd. Marseilles. II. 61341 Sheet 1
of 1
Unit i
W.O. # 508317 401 Repair Organization, P.O. No., Job No., etc.
Address 3.
4.
5.
Work Performed l vU Me-hsnIpal Mtalnfannr' (Name)
Mechanical Maintenance (Address)
Type Code Symbol Stamp NIA Authorization No.
NIA Expiration Date NIA Identification of System (MS) Main Steam (a) Applicable Construction Code Sect III 19 71 Edition S172 Addenda, Code Cases-1567 and 1711 (b)
Applicable Edition of Section Xi Utilized for Repairs or Replacements-19 89, No Ad, Code Cases NO Identification of Comnonents Renalred or Renlaced. and Renlacement Comronents a.
Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
Safety Relief Valve AG N63790-00-0007 NIA 1121-1F013F Replaced N/A C ro sb y Safety Relief Valve AG N63790-00-0110 N/A 1B21+F013F Replacement NIA Crosby or N63790 Receipt #94701 011 0(Modifled)_
Disc Insert N93185-38-0101 N/A Replaced NIA Disc Insert AG N97499-43-0101 N/A Receipt # 94701 2003 Replacement N/A C ro sby 7.
8.
9.
Description of Work Class I Revalr & Replacement. * = Per N-5 Code Data Reoort on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I__I. Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 Dsl Test Temp._165 Deg. F Remarks Valve SN# N63790-05-0110 was refurbished at Wyle Labs with documentation provided under Quality (Applicable Manufacturer's Data Report to be Attached )
Recelpt # 94701 and Installed as a replacement for SN# N63790-00-0007 under work order # 508317. All bolting materials were reused. A visual examination VT-1 was performed on all Class I Inlet bolting.
Renlacement SRV Serial No. was modified due to the Installation of a new flexl-disc seat desion.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl.
(repair or replacement)
Type Code Symbol Stamp NONE Certificate of A orization No.
Slgned n
5 l1A
=wnlJ,,aunot "Ing V-xpelauW11
atv N/A ISI Coordinator Date 0-7/01!/
. 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois -and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have inspected the components described In this Owner's Report during the period LlR09 to 1R110 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising fr m or connected with this Inspection.
02t/
'ZL/I/. i Commissions IL 1927 Inspector's nature NationalBoard, State, Province, and Endorsements Date_
32004
Q.C.-392 Sheet I of 2 K>
JFORM N-2 CERTIFICATE HOLDERS'. DATA REPORT FOR IDENTICAL NUCLEAR PARTS ANI) APPURTENANCES*
As required by the Provisions of the ASME Code,Section III, Division I - Not to Exceed One Day's Production
- 1. Manufactured and certified by Anderson Greenwood Crosby, 43 Kendrick Sr., Wrentham, MA 02093 (Nanie and Address of N Certificate Holder)
- 2. Manufactured for.
EXELON GENERATION (Name and Address of Purchaser or Owner)
- 3. Location of Installation LASALLE COUNTY STATION (Name and Address)
- 4. Type DS-C-63790-5 REV.A ASME SA637 GR.718 185,000 2003 (drawing no.)
(mat'l. spec. no.)
(tensile itrength)
(CRN)
(year built)
- 5. ASME Code, Section 111, Division 1:
1971 SUMMER 1972 1
(edition)
(addenda date)
(class)
(Code Case No.)
- 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
Revision.
Date (no.)
- 7. Remarks
- 8. Nom. thickness (in.)
Min. design thickness (in.)
- Dia. ID (ft & in.)
Length overall (ft & in.)
- 9. When applicable, Certificate Holders' data reports are attached for each item of this report.
l *
- Part or Appurteniance' Serial Number j
.. 1) ' N97'499-38060 K j N97499-38-0061
.3) N97499-43-0098 (4)- N97499-43-0099 (5).-N97499-43;0101'-
(6) N97499-43-0102 (7) N97499-43-0103 (8)
(9)
(10)
(11I)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)_
(23)
(24)
(25)
National BoardNo.
in Numerical Order (26)
(27).
.(29) -
(30)_
- (31)
- (32)
- (33)
(34)
-(35)
(36)
- (37)-
(38)
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
.(48)
(49)
(50)
Part or Appurtenance
,Serial Number.
National Board No.
I in Numerical Order
... 1 k
- o. r
- n pressure psi.
Temp.
°o F, Hydro. test pressure 2370 at temp. 70 0 F Ku (when applicable)
I 3upplementnl information in the form of lists, sketches, or drawings may be used provided (I) size is t8m x IIl (2) information in items 2 and 3 on this Data Report included on each sheet, (3) each sheet is numbered and the number olishets is recorded at the lop of this form.
This form (EOO040) may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300. Fairfield. NJ 07007-2300 I
/-uz:;
1LU 4:
HI; UV
%I -*
I -I'L; V'U I '
U V II II 11 l
, 1*
.9-dilol0 Form N-2 (Back)
Q.C-392 Sheet 2 of 2 Certificate Holder's Serial No. N67499-38-0060 CER7FICAT OE COMPMANCE we ccr=ri that ffie statements made m tbus report are corre and that this (these)
Disc Inserts conforms to the rules of construction of the ASMB Code, Section Ill, Division 1.
NPT Certific~tc of Aufthorzadon No.
N-l7 Expires Sep. 30, 2004 I
SAnderson Greenwood Crosby I
Date
__-A__-0_
Signed wr MA by r.
7 1.
U(PT Certificate Holder)
(Authorized retepsentve)
¢ *r
- S S
- 1:CE*
C TI E OF.NSPECTIO.
I, dieh udersigned, holding a valid commission issued by the Naonal Board of Boiler and Prssure Vessel ]nspec;Ri3 and the State or Province of Massachusetts' and employedaby Factor= Mutual Insurance Co.
Iof
.Jobnston. Rhode Island h t pected tese items described In this Data Report -on lA_,,~ a JC
) P
, 20 o3 and state that to tb6 best of my knowledge and belief, the (Cerfifoate Holder has fabricated the parts or apprenances I accordance w-ith hie ASM Codc, Section m, Division 1. Each panr listed has been athorized for stamping on the date shown above.
By signing this certificaw, neither the Inspector nor his emnploye; makes any warranty. expressed or implied, concenung the eq(qpmen descz1xed in this Data Report Furthermore, neither die Ispector nor his employer shall be liable in any manner for any personal inucy or property damage or loss-pf any Jnd arising from or connected with this inspectionL
.. I.
I,
Commissions _
4 -
(Nat'1. Wd. (ind. endorslene) aid State or prov. and no.)
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way, Kenneth Square. PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 Address Data n2r1RInA As vZwsv_
Sheet 1
of 1
Unit i
W.O. #508318 -01 Repair Organization, P.O. No., Job No., etc.
3.
Wrl--
DaS
~
v 1v IkA Is
-to - -
TVu I reiiui oiiu maimenance (Name)
Mechanical Maintenance Type Code Symbol Stamp N/A Authnrlatinn No NIA Expiration Date NIA (Address) 4.
5.
Identification of System (MS) Main Steam (a) Applicable Construction Code Sect Lil 19 71 Edition Sf72 Addenda, Code Cases 1567 and 1711 (b)
Applicable Edition of Section Xi Utilized for Repairs or Replacements-19 89.
No Ad, Code Cases NO Identification of Components Reoalred or Reolaced. and Reolacement Comoonents 6.
Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Bulit Replaced, or Stamped No.
Replacement (Yes or No)
Safety Relief Valve AG N63790-00-0108 N/A 1B21-FO13D Replaced NIA C ro sb y Safety Relief Valve AG N63790-00-0006 N/A 1B21-FO13D Replacement N/A Crosby or N63790 Receipt # 94701 0006(Modifled)"
7.
8.
9.
Description of Work Class I Repair & Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I J
Pneumatic II Normal Operating Pressure I X I Other Visual Pressure 1040 osI Test Temp.
65 Deg. F Remarks Valve SN# N63790-05-0006 was refurbished at Wyle Labs with documentation orovided under Quality (Applicable Manufacturer's Data Report to be Attached )
Receiot # 94701 and installed as a replacement for SN# N63790-00-0108 under work order # 508318. All bolting materials were reused. A visual examination VT-1 was performed on all Class I Inlet bolting.
-- Replacement SRV Serial No. was modified due to the Installation of a new flexl-disc seat design.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xl.
(repair or repl, Type Code Symbol Stamp NONE conforms to the rules icement)
Certificate of Authorization No.
Signed e e: C L11A CAt**OhIIJI blOW
JJIIMIVII
MW N/A ISI Coordinator Date
°3 /°Z/
. 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issuedby the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller lnsp. & Ins. Co. of Connecticut have Inspected the components described in this Owner's Report during the period LIR09 to 1R-110 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
l An L-it/
-'~h-Commissions IL 1927 Inspector' ignature National Board, State, Province, and Endorsements Date
.3 2-2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 Address Date 03/09/04 Sheet 1
of 2
Unit I
Wn #15531 Repair Organization, P.O. No., Job No., etc.
3.
Work Performed b%I Moechannica Umanfeannne (Name)
Mechanical Maintenance Type Code Symbol Stamp N/A Authnrizatinn Nno NIA Expiration Date N/A (Address) 4.
5.
Identification of System (MS) Main Steam (a) Applicable Construction Code Sect III 19. 71 Edition W'71 Addenda, Code Cases No (b)
Applicable Edition of Section Xi Utilized for Repairs or Replacements-19 89_,
No Ad, Code Cases No Identification of Comnonents Renalred or Renlaced. and Renlacement Comnonents 6.
Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
MSIV Stem/Stem-Rockwell N/A 1821-F028D Replaced NIA Disk Assy.
Corp MSIV Stem/Stem-Flowserv 763664 N/A Size 26 Figure 2003 Replacement N/A Disk Assy.
e Corp.
1612JMMNTY Valve Receipt # 86948 Piston Assembly Rockwell N/A 1B21-F028D Replaced N/A Piston Assembly Fiowserv 24-4950-19 NIA Receipt # 86971 2003 Replacement N/A 7.
8.
9.
Description of Work Class 1 Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted:
Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks The old Main Steam Isolation Valve (MSIV) main disk and niston assembly removed from MSIV 1B21-(Applicable Manufacturer's Data Report to be Attached )
F028D was reolaced with a new style Stem/Stem-Dlsk Assembly with SN# 76366-4 and Piston Assemblv with SIN #
244950-19 under work order # 515531. Parts Code Reconcillation ner Eval 3922 and 1998-0264-000 for both Stem/Stem-Disk Assv and Piston Assy. Additionally, four (4) bonnet to body studs and six (6) nuts relected during VT-1 exams. were replaced with new.
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this of the ASME Code, Section Xl.
(rel Type Code Symbol Stamp NONE Replacement conforms 3alr or replacement) to the rules N/A Certificate of Autorization No.
Signed MIA Fnntrn ntr non ws~ulaulll va.
ISI Coordinator Date 5/
.0 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Insn. 8 Ins. Co. of Connecticut have inspected the components described in this Owner's Report during the period LIR09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner forany personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
- Com s
Commissions IL 1927 6yispector's Signature National Board, State, Province, and Endorsements Date
/'O 2004
FORM NIS-2 SUPPLEMENTAL SHEET
- 1.
Owner:
Exelon Generation Company (EGC) LLC Sheet 200 Exelon Way, Kenneth Square, Date PA., 19348 Unit
- 2.
Plant:
LaSalle County Nuclear Station 2601 N. 21st. Rd.
Marseilles, Illinois 61341
- 3.
Work Performed by: Mechanical Maint.
Type C Name Authoi MrA-hfnl^nl RMfinfannno-d
=wnirft 2
of 2
03109/04 1
W.O. # 515531 P. 0. No., WR No., etc.
'ode Symbol Stamp N/A rization No.
N/A tion Date N/A MIJE a 4.
5a.
5b.
6.
Address Identification of System MS (Main Steam)
Applicable Construction Code Sect. III 71 Edition W'71 Addenda Applicable Edition of Section Xl utilized 89 Edition No Addenda Identification of Components Repaired or Replaced and Replacement Components.
Name of Name of Manufacturer National Other Year
- Repaired, ASME Component Manufacturer Serial No.
Board Identification Built Replaced Code No.
or Stamped Replacement (Yes o r N o )
(4) Bonnet N/A 1B21-F028D Replaced N/A Studs (4) Bonnet Rockwell Heat Code N/A Receipt #
1983 Replacement N/A Studs W3 L95-00856 (6) Bonnet N/AA IB21 -F028D Replaced NIA Nuts (6) Bonnet Rockwell Heat Code NIA P.O. 268008 1983 Replacement NIA Nuts 5AE
141 0. 1ff3/#0/
86971 FORM N-2 CERTIRCATE HOLDERSW DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provislons of the ASME Code.Section I Not to Exced One Days Production pg. I of C" U t n ;"
b Flowserve CorporatiOn, 1900 S. Saunders SL, Ralcig, NC 27603 1Uaniufactutd and certiffad by
- 2. Manuiadurd f Exelon Generation Co., LLC, P. O. Box 805388, Chicago, IL 60680
- 1. Locaion.of Exelon Generation Co., LLC, LaSalle Station, Marseilles, IL 61341
- 4. Type PD-422884, R/B SA-10S N/A N/A 2003
- 5. E Cod.. S.on t. D~don 1:
1971 Winter, 1971 1
N/A
- 6. Fabrkcted hI accordaeith Cona. Sp1er (Div. 2 on~o N/A A..
N/A Doe N/A
- 7. frfs Material meets ASMESectionll, 1980 Edition, No Addenda. Disk-Piston assembly forsize26 fieure 1612JMMNTYvalve.
N. Nor thJkness on.
N/A Mir. design tideknas W Per
- 4 Dia. I (tr & m.Q NIA Length woell (ft & i.1 N/A
- 9. When applicb, Certificate Holdes Data RPopa we autded for each km of tis I
fai or Appurteence e"d N.
serit Number hI Neal Order m
24-4950-19 N/A (2)
(3)
(4)
(5)
(6)
(7)
(8)
(9) 110) t11)
(12)
'13) 214) 12) 1241-NI 123)
Pert or Dppafmeem goe No.
Serial 0 erd In Nurinericeh Order (261 128) 1291 (ml (31) 132)
(331 (34) 13S 136)
(37)
(381 139) 140) 1411 142)
(43l 144) 1451 (4q 147)
(481 (491 (501 '
- 0. tDeS;".,,,jt,fwlf
..n..- pi len
- l
__ _.. 5_. -....
,X sa. mre v;_ ttr
- Supolemoital Wormston in the form of its. sketches. ot dtawinge aur be treed Iprovidd fit &
S is f,/ S 1l. (2) information hI tems 2 and 3 on this DS Ralseol Is Included era each shet. 131 each shoot ls numbered ard the number of shset is teceded St 4 to p tofWs frrm.
P7A This hem 9o1od0 ma be e aiewd from she Odel Dept, ASMI. 22 Low Drive. Box 2X0. FSrWrWei NJ 07007-2200.
- 22.
.Po 2
- e wiad Boyd Brobs CA e
13655 4
.z, Dein egw eai~ded by P.E. State Pau. no.
We
- .a tha t
n i
oa corec and ia, ithesel Pats)
'c*^or., to th foles eo inastn of Ow ASU Code. Sectin KI Okelon 1.
rdca f
O.
N.1563.
November26,2003 DataNo Flovn'e d
Cg, s
UT1A!OF PWISFCTO L the wjd.Id ho*vadncog a valid bftd by u Nimnal Bard od Bsw _d Vessel knspicr and the Sut Or Province North CMlit aw armld by HSR CIT:
HartfrC.
a id ts bd h r
Dat ot on a
to beatof y kowldgeandbe~i.
Crdlcai Hoderhas e'l Id Ama. pwut or appurtenances In accordance wt h SECd.Sco be j Wz bpjde a#nd begeth Im Hddth#
the AS Cs oda-Xh~e, S~ecton l
- . t.
gSi DI{slon 1. Each pat ssd logas been 8 d
r staor hn en the o
an O
ow nd aboe..
- e.
mIr t
sh cors mrnlova Bs rf.
t described n ti a
- o.
the te eor hnoris epor slwbeSablnynnn wo apersoakljyrpty damage or Ions of any MWd ain from or connecled with We Date Signed It C
os r
M
/.
.ft
's.--d A
FORM N-2 CERTIFICATE HOWDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES" As RaquIaed by the Provslons of thU ASME Cd.e, Section NI Not to Exced On. OWD Production Pg.f 2
o
_______;_b_
Flowserve Corporation. 1900 S. Saund St Raleig, NC 27603 1-
-d add.- of 01" Ca"Clo iua-
- 2.
d Exelon Generation Co., LLC, P. O. Box 805388, Chicago, IL 60680 1-a-d e.
P-"
3 L >eU1N Of &U1.O.b Exe!on Generation Co., LLC, LaSalle Station, Mameilles, IL 61341
- 4. T~
PD422884, R/B SA-10S MA N/A 2003 Pj-W wein aej fr" wd 1b31
. ASa1E Coce. Section DbM-ms 1:
1971 Winter.1971 1
N/A
- . Fsbelcatd n accordane-w t CanaL Swc jO;. 2 *W N/A NtA o
NtA Material mects ASME Section 11, 1974 Edition. No Addenda. StemlStem-Disk assembly for size 26.
firure 1612 JMMNTY valve.'-
- a. MOr tidu'ess a N
1an. design 1dhcks lss Pnj
&%Q - PCr #4 cis, l tb a i
.j A Longo, ovI (It & kj WAfLP.
o-
- 9. Wm appicable. Coelikate Holde1si Repai bettecl Sw each her of ihis repori:t o:
P 76366-1 NIA g.
.2) 76366 -
N/A
_..._tn_._.__.____,_
.-..t-74163664 -:<-r I N/A Is 76366-5 N/A (a)
(a) 193 1-."
asll
'112 1121 (133i (143 (15)
(16)
(17)
(183 1193 1203 (211 (223 123)
¶243 _
¶253 I
W
11 4t
.i-11 11 125057 10 Dfeign gurnssisre tjstrn
_t it,'
i'..
F.
N/A,
t
-F S pplwnentat information In tho form of liss. sketches. of drawings may be used provoded 11 site s 1'h
- 11. 125 information In Items 2 nd 2 on this Datt Report "
Inctuded on each sheet. 131 each sheet is numbered and the number of sheets Is recorded at the top of this form.
Il/W This form (E000401 may be obhiased from the Order Dept.. ASME. 22 Law Drive. os 2300. Fatrlfeid. NJ 07007.2300 0
I O/
,i"v2
,J,-
- ffi}
>. o~t.¢etadw Boyd B rooksa:......-t l.s*
C l -i16S Desgn spocitsdacerttlod by
- S sX#'......
S"
, t-r.-j,,3 A Design M.
cairted by l
F PEj.ES
$rWe
- r.
.tha d sta eaw_ sude In Vs-rpor e 'a cn
- M I $(Sos -i.>t
,.nf'mtoth.
Me co dnsd ton 1.
the AS Cd.
PT C*6cofdoNo.
N-1563 E.
November26,2003 Dae k"
Flowsee
-s.i
-'.4i.
a hu ?aee
- ; -.d 1Dobllr e
a; d did esV il hsnd w State or Byr sinn
.ii
' t3--
f cett~lceae. mher the hseor not Mawal ay e
~
s may.inj.~etweaedo bupe d. coamng Wi equipmetdeied s ? or blos
. ay hind se w
dl
- +
_,.lJ,,J,
- '+-
4
- A:.
i A,
.,~w on!
f L
W,
.1.
1 A)
A 4
Date igne
- g~v¢¢~@
8l*k Wr-
";'s'"
>4 4;- JZ_'
>i' X tX l*'lti~S~s"<.iaf*.Q~w~i-+F;;iX 72 3-,
e
.>.~~~~~~~~~~~~~~Zm "ja illi~e.
-t2.'.,
r-^^-,+,-Xj>*.
,s**t
>^
=
s4;:
^Bd
'V
.^R>-
T T. -ck Nof.
d 4' *I';i~tr-2 42T*t<,r
_l *.
e 3;s-, ¢.-.v ~v:
- s!.*VW.1~1
_A.-
-or*
- Ls4, id',;-nto MI3 me b Mj
'i.
s n.T t T.,: IsOF tr -
.-i+.
o
'Kn ASpc.
-7::
.:;;i;fti U--.
,o}','~r
~,,sr >~i,.^ r - _"_ s - n"}.4;.+*-e wf t Not":*
o go.
v......
¢,....
x; f
8*
- i -,;t.--zt§:.
.F i!6 V
C; V; e b* Or Ul
'X
- '4 Xbt i
- ia
- ...4
+
8t 0'<
[tl21~:
r;
't~
outletj drin)
.Nunmbor ln Marr Pes"
-TV MJ mtviclf;
-SThlcknos mataf:l Now Attachc
, ; ; ; ~ ~ ~~~~~
A.,,.._.
S........
us ;":in~i>71 No.
L ocation V crew _4-¢tart thc itwme'hartigisot
- or i5 iin twa cbr NW thi as"'
s~tt.\\on fa am tos 4 @~N5dtiS Et t
i;
¢!r;
-Z, t<
- -^w
.M
?f
,t
,;s v*-
nd D~ign R~ot not~fie t~it i>1 fs NPTCitft:H ri>nN nit'AJ
'ffist-. t S -];.'#
of. thiF ti i i e H
- S P DE
'n>SnRt
- ^Z p*eb N-s A:,,i'n T Viti Jztwt I
DM 4-19
.19 83 WspeRoekeell Int"l Cormeys
- Cag r r cte Hold er);
ve "
it -.
yp
~~~~~~~~~~~~5 6 t~ i,
'< -t' -
Se:#t iN,. l r :r-
{ 8 s '--'e15"6 3,
- '>-^*
S,,)*
ietcivd4 Bil Pro
-EngS-lif P sve.,,
,^
edi f_,
- JX
\\W.3t..*.
+
dR.;--;&....,,9til a
-SaaheAAL
-a
- 4 S'.its JJEiej4 e
6
--' d ¢ -tfoA*-
=-t
' $2 ~t-
,_f@p~f sf-pwu@*
be~sl ibod8*
l^l
' k
- tFM Do
.tt rS"F PF
- a "t-bn't 1OVwi;
'O the bW Of v
J-
'ii k
t
-2Z~~o a fS~7;:t~
5-ss.SHt.tS x=~
-~~
m
-ICt tne.;*Qi;411, CO t1Xp.Iinol
,:}
~_ Projigt! LaSille
-2 "4
Shll
'Mtr, 0;at" r
No S
m.-Mt*
@ThsoS6A1^x~..i:f~
Lenth
@4 i*
.Scafrni:
-Long HT;T.
,T-
,iin:
- r ~
G8t{St
'(irtih"'<
\\
HTI
-l^'i$
No. of Coutrm~
-,i; ds: (a)Mwjw' 14 I &'T'stf-"
a
?Tb)
Materisit T.S. ;
ij!,'.
-;Locati2n]
ltop.
t Eown
.,KX uckl -.lripicc; onkal..
HmSperriDSCrll FlatZ Sias Iot or Ff.... ;; <':Pis1::r- ', :'.'.
',:, i;.di, ;,, itiol..........-s RR
...A..,A,:.,
i < ;
fl rernovtble,balts;utr-Ohr suion g * -- !
' ^
t I~~tster~al Spec. No. TSB+
to, Numb rj ;--Z:
Zt tb*rttt'sec s
r--
SSi,,,z, s
7, :Jackal Clo ~Uri:
- K$
sb 11.1,'
'ube etv Sts a ionar ' Mtedt ism
';tl, ttach inx.........................;';4
(
Kind.Srcc. No.)
(;tSubject to proi. ! SAt;"
Weldodt biled);?:r_
it^J';-:g;;;v^Floatirig:
- MiirielDt
~
zln.Thk.
'l n-~ 'Attahritnt 10' xJi.
- Tubes, Mitcrbal' O.D h
':'l op.ubr-Tp o-
, I Straight of U)*
r~~~~~~~~~~~~~~~~~~~~~
-r? - - - - - - -.............
Items 11i-`14 inclusvevf to be completed for inner chambetrs ot1 eskatvdedsens ch or cintilicif hea cxchanqers e e N1/i t,-4*c,;r*...a.
M.
I Sh
-11 5h.
Maitrial
-T S.
Nom;.Thk._Ina;Coir. Allow.
In. Diarn. Jt.
in.
Lcngth fi._in..
IK
@Ind Be IRPM-NO.).
(Mi"n. of trang soellied}
t ilgE'-
2Seems, -Long;-
H.T.
E Rsr^-flficiency dirsh H
l tT _
No. oi Coursel
'4';';3 Mq4Xicd fa~zr I
'i8 'TS.
IMaierfl`
TS.
r
.t
<.!~Dt".
s*rCrow K nu 141 1b Flpi~icl' Conicl'.
Hemispherical Fla i SW. to Prnrui v,~;;9-t,,
t' t,,iion; Thgickness Ftdiwi AS-614S Ratio Ap.3k Any#.
edius
-0lsm. '
jconver oreecA S
t'28g t.;i,,;,2 i,¢~o~w Wt~orn arn
.......... 1 mmNI To; AI-m!lb i.e a
4 t;,.i lu b
S S
Ii. Chno
,..2lFg
rXSl EZ)rJ]
"keab iX l l4 4;"-,'!'-,¢-,^8..
iey e'i 04
- 0.
fi;vmswr,6 s
~
a 1#IV
.u~t ir'n Typo; -
j;,
- 17.
lnW41o Manholes No.*IJ Loc tion--
w~s(
.Openimpt Hadhaols:
No.
lis~t Location.
>r;,
e Threaded:
No. -
IC-Lsln_,
o--_
AI S u~pports, gIlrt
-Lus 01~
-Ohei A~ttched -
lys" be Ino e
trl Nurnbel olt.
m ID~vetberl jZ.....Ztt,1 Wa.0,,, W rthat thet tSlateent
- lhhitotwrctI h1 madto poeli n c ihtlii110Ce~i 0o, si 5Hl!,<
tt ib ola crin truction nl ihAik ction ll;-'
X
)
Tf"'h ITc licatbli, Dsign Sp cifeatt n'sid tsign spo t'are notshst
~ponsiiiil My'o ti11T Co Tni fcll "cHold ilorpr 16f
-k,,> ;
.certianficatc Holotr forf ap~puricrnances1 ie paonWisibl -of prnishilng a separeta Des;, n Sp.jicitk~ end Desin l 'Pon ffh'i rt
- i ir,
,ncrtr Is'not imclubsdlin ti cr n ent Dsign 5
!!on
'n Reaport.),
E Di q >l S
4-19_
,98 Signed-Rockwell nTUOl C o r
~!
a MB,{PT Carificisto Holidti t,
Qualt tA ire
,.s,;-
,CERTIFICATIlON OF.D6ESIFO APPRE N E(wi en app!;
l '
1i' 'i a
4 3 (~iAJ?#
.s<..94i
- ttit t" 'Isls repoirlbt'o e f
si -:`^Rcsckwell*internat onaliCo nRpmohZN 70'4E';itt.'.<^'~F s J ?. -ft!tcific~tions $c tifiedf Byv ro-P Pof.Eng. State Reg.o13s tf4~
-' 4*<w-t ;
4't5'4;CERTIFICATE OF.SOP INSPE T1l1 r !t}i' ;'-1',
Zt 1; the underIgned~ri'oding xi;"iidc mitnr;
- cltoito(rto;Bde
'Presni sli*Sinc tfs o t-hSiit's orito Wg;'
Potnst'vorth;.Caro1ina-ut'--~
!:^^S2'Fidmlyd^
HSABI1'&
IC6}t_8 B ar-ford; "h.-l I
hrtw the pan o1 b'OritsuWisa r tw srietcl In thhts
-Pria D;#
ant a Report on
- O>_I
- L- -/.
, 19&
and state th t, to the betxnt ikofbg my I~ti;drdqs f fv
£; I
- r t~j#te
.thb~, t.<it*,
r rth~f"j~ns cjlrofr o his,,
ployer~fmake iAy- ~rWr tV;-ixpnss d of Jr pl #d; tonc fer ngthe'aft l
nr.!
w ;-
rtd*l h>.ui D
ReotFiinhormora,`Nthefltho 6#so.o ieniotisilf
~iblit'in rnarf fnfir tor lny
>fi
- iv5, Xr~~q!
injufy or paroperny d nam ow a lost el )ny kind vising fr' rtn td wt hs!s'ct'.--u#*
I p*o
'once wor'lh-thi~s' Inp-t~Ai.'°. 3-ei~
~
q rrpj=>r,<=
zhv5
.~s8;;a ttjn s
Nationl *oad. State. rOvInCon and No,
- ~~~~~~~W4 --
"Nei:,<.ix,--^~f' 4-i---i 9X7
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA., 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 Address Date 03108/04 Sheet 1
of I
Unit I
Wn-5i15532 Repair Organization, P.O. No., Job No., etc.
3.
Work Performed Ikw Maechanical Ma2nfnannen (Name)
Mechanical Maintenance (Address)
Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A 4.
5.
Identification of System (MS) Main Steam (a) Applicable Construction Code Sect III 19 71 Edition W'71 Addenda, Code Cases NO (b)
Appilcable Edition of Section XI Utilized for Repairs or Replacements-19 89, No Ad, Code Cases NO
- 6.
Identification of Comi onents Repalred or Replaced, and Replacement Components Name of Name of Mfrs. Ser.
Nat'l Other Year Repaired ASME Code Component Mfr.
No.
Bd.
Identification Built Replaced, or Stamped No.
Replacement (Yes or No)
MSIV Stem/Stem-Rockwell N/A 1B21-F028C Replaced N/A Disk Assy.
Corp MSIV Stem/Stem-Rockwell 214856-4 N/A Size 26 Figure 1989 Replacement N/A Disk Assy.
Edward 1612JMMNTY Valve Valves Inc.
Receipt # L89-02460 (3) Bonnet Studs N/A IB21-F028C Replaced N/A (3) Bonnet Studs Rockwell Heat Code NIA Receipt # L95-00856 1983 Replacement N/A (3) Bonnet Nuts N/A 1B21-F028C Replaced N/A (3) Bonnet Nuts Rockwell Heat Code N/A P.O. 268008 1983 Replacement N/A n__ _____
AAI^
_ l
_ _no 5A
_ _____________A E
I.
8.
uescription oT OrK:
WM
- lass 1 ReDpacemen.
- = Per Nr-t.00e Uata Keport on Tle ax La8anle Countv Station.
Tests Conducted:
Hydrostatic I_ J Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osi Test Temp. _165 Deg. F Remarks: The old Main Steam Isolation Valve (MSIV) main disk and olston assembly removed from MSIV 1B21-9.
(Applicable Manufacturer's Data Report to be Attached )
F028C was reDlaced with a new-stM&eStem/Stem-Disk Assemblv with SN# 2148564 under work order # 515532.
Parts Code Reconcillation per Eval 3922 and L1998-0264-000 forthe Stem/Stem-Disk Assy. Additionally, three t3) bonnet to body studs and nuts relected during VT-1 exams. were reolaced with new..
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xl.
(repair or replai Type Code Symbol Stamp NONE Certificate of A thorization No.
N/A Expiration Date Slainnd ISI Cnordinator D
ategv-cz/-,
conforms to the rules cement)
N/A 7
. 2004
-
Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois -and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to 1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Cs Commissions IL 1927 Inspe fr's Signature National Board, State, Province, and Endorsements Date 3
X 2004
I K-i:)
Po(W P3 2 CLRTIPCATt HOLI' DATA rWm FM lM NTt a L8 9-O2460 NUC.ZA PANMi ARV A~PFfVU2 A*=vU A PWArvd by tss omaka of Ut~AftA Coth. kaUtn W 141 To Etcs*o On* DoY's PO-luctm Pa.
I t p amo.
I 1.
2.
Moft,.
lwtd ax t f t* 01 0100
.LE.W Si I
J A-....
/
F. w^.
^.flS
.wo e_,
i
_E MlWeflPod NW -yv LDArAPtrO UZENLt r
XIM-1 L.a. _=
LAS&L-Cm~rY -Smunrn-MA,,vmcrL1 ZL 21
£a~J*3JI
- 3. t s
- 1 ltt
- 4.,,,Ig LSSL-n10-5 tBA WA
'I
,2 I
C.A 1
S
- 6. AS1UPi
..SarmA 13:
19 71 iIJtrrnL 11971 I
A11
.1 s
-- ~
- 4. Fawketecom mceeodame.
- .vt Cogt.Sp I.
2 Ie~l y IVA WA
-_D..
C~-r E.,
Vr-s. 00 g-,
&LS. tP--.-
7.
womierts~_:
_---Ar
~~~~~SD, 3~;f6f*
_ A. _.
0- J___
_.g.
- 9. Nom. Icbnn, I.n.1 XE Mn. dn.n tSIM b"A
_Xn2 1
0(N. 10 IftI Ii.1 h.b Le tqd oerad Ih & h.l - WA S. Wl~n *wobC*W. Cortatsio t4idd-Data PooonS V* attaltd Inr each ite of tgis t~gor:
K
.I Pon otr AporomehIc.
Natim 5N tNum.
>bd IYo.
.in N40nicgCe Oder 142 W
IS)
I _ _ _
tIII 121 1213 t141.
tIs)
'172 lst$,
- Ia=
'201 121) 1221 1232' 124-1251 I
tPtrt or £^ _tmmeetiYt
- 2) t wn iical Order 2622 1201 1291 2321 2t332 1
1342
.13.
1462
. 381I 1391 1402
'411
- 421 147S 1471
- S(.4
._1 50}
I-S_)
to. D "swunu., rzso L pa' TON*.
F. Hy"tw.
tpj Nt.'
F lihiduied m eadi iew-1b e-A iSbn I
i W
m 20 1w2p.
n222116 tN@Pp 1 £000 1,MOb tr iw OW I
rOW 99 O t.
16 122 U 0 *...ha200. PakW i NJO~
0 072300.
1*
1 I
VP 1"
N -
- .l l
w E
l el
- g.
l 3
i l
l l
l l l
- A9Z*'
7~%&t
%.crv 4~ P. w
- , -..,~
- t?
Rc a
ua C
2b
-ft rm0 : L89.-°2460 At.*:
.,,§ Ak t*.Se s Mt orsrm owra~
Dessa t:ncamtntybedtt REY¶I ftaerc P.S. State 5,,in tm.,. no.
S&.
C~ rncu eeoutfled y P.I. stat5s A.... me. no. -Sta CEMMlATt OP' SHOP COCPUMCU W.envVa i ttnw oeb oeno u ee e iwoein PA QTs coniiom to tft rnti ef cotocintof oft SIME Code.Section I.
D"t 2//
feps 11126/-
,c
_~
r C,
E*_
Do c
waefrSlld CE1RIVI7 OPF SHO EISflCfM et fw1t4dt D
n A_{ Wtttntefr C
of V'e ndeulid badig vli CnpCAWWIO need byo t6n beynd es olneone isa, VielueostdunSafte m Agvic bet of my knowtd end bewe. ti C5.Ifitet@ Mold, has fabulrcatod ftose ae if W oou manco n actordancs with Ow ASUM Code. Section
- . Each wWatd 1baa1 btn souOlfsd lfo sn S qnO eats ealn above.
Sy "hsigagweemflcas.
IWt i~f Veta etClO'SCN Dn~~vi mabs ow onr. espeador fllid.cleuney fset~w aeed baanlwbo4lds u r ttedto e Ov eeoetioreo feexoUjvseedeeton.
b l r e sin eci-i *s.
r s.,.,e JC ' ¶.
r
- 4 Do
-ffL K-f 3
=tsHos lkwm S ',;
t5.r
<<C
- 0>b tt2
- e.,
-*tt s~ltbr' nff
+
- aqS1*iiaY'
~~~~~~~~~~~~~~~~~~~~--kib
!;0j
_tht "
f (2 e
q;,o-j ;a S g,
- +-
S}'ret 1t' i*1n/_gne:2;;:£;^?Sa;>;¢-t;* 7<l ot,,..>.............. z. >;>.,@,~v;-s'>;+;<s-9S, s>+.J-;*ii~<>-->t t,*-/t-,,f' AWE..............................................
^
t~~~~~~~'4 29 ' ';\\..........'
l..=ti..
s1s16Si'.t.${9>'"tlXi8;"".-e^'lt.,'........................I d............1.........1..........................k so i,
!LSa
~ot l..
R.T.
EtlW emy kd
-arTb HT'o.lt Jof QwM P
.. >w t**i
!, W.
SOCL Pt T,
<.~ ;,0.
M--
(Dwg
- w seh.
^t A s i
e.1@
'*,,n-,
n,; ---,
Re:
~.z.....(Kind........
SPOF
).
Lj.i; ts
~.'!,ip.
w =Iin 4,A ;§t uo,
,,%~et Wjig
.'.'"",',.,.--n n<;';t
,.i 6 owl, YNOMMi" X-1.
~,;
-'t
.;~~~~~~~~~~~~~~~->;'.r.tfolo.
J4W Ul^>'...'t:-
8>
W~ S*St-O8 v
S ofe vpt
~
A-r is sX.
t*
I i t's:,
t -
-'.i C
i J,"
_t t<;
- -.s, j s f r w 46 lc, r bf4h g>z!
JtC¢..il
<-$ts ei t<
4
+~t
> ~v wr Y's~<*b_
_Zi h............._-v>;,
_J2s'.;
- t.
- s
- ^..
'f~
&'t'+'^
~'
'~Tr
'gi
A.- VA.
.S.Sttev utsn 7Number I'
Ai:^Lotion II
~
.ouvtt.t Crair N urrtilf Dism or SIXO J
Materbia
- 'r. hctte aea Now Anmchea 77
'm Omnng:
No Isz S
'Loegtb t
1 Th r
.,,No.
siz Si Loc tion v
- 8; Qon:SinLurLe~
4
^
ti Attschod
.ot
- .*........s..1,a.e~
ftsO
.sk -tU t
%f t),-*fi
^
'{it S L ;<'tt&1*
- tw
- t-+~~t _~Szis -4.t i. 6v ^ w Cx iicstr§de omur -sw o ;
ilp pcition o~dD;g
~
f sa-it$-<-
fif le Me A.:c fDegilSpel
- .s
- X t,^.I'4tf 0-4. NPs
- T:. -Ci;*-tiS i
-f N'sf Dst 4-19 ig 83 rpidRocka~ell. Inttl CrDpty
,of,.
S ;
S t
Ei;
- -11~-264 5.@
awS; e.tiims c
t'
)4;6
- " iN-1563 4*'s
}.
s
- f. ;
~~`A1NvssOr F.-
N-t..^*z s*bto;Ar d.-NCE r..::.;X ;
.CE *; ;
rb-*RT1FootDi FOTWSE i 4l'$ 8-§4}9 4 ; l I -
r i..
- to-., 1:. ouill fe, tRell Inetiol isp*wrlidxtj lC';2 703XEV4;>'l 5 i w;;z X-_ s
- 1 ng;,..t;-E;IA 4't$:§\\&
.\\S}
i AI.7-i~i l-st a,
.R
- i.
n ei or~
iihK2
- >t(s.
i a
t l i*,* ;>4 w <~~~O IN tSP!-EC 5rTIONrw2<@tl-tv
.r;
].i
- I U'
..4IA I en Upi A_
":H anew@:;
- v J of ^
- L; <
- >-_
- . i i Levi tax.. -
',' '; si..-.
,,,..ri
.ht i.
. s; f '
I':,
A..
It.!'.
.b
,: 0.,.,
.. z
': z
.z
-. t*7 ", t,.
vld cimm w;s;i S ommta;;i d -of 1l1 a
PrelimWs;=* -~
- -drvtfod.-.C.
thaplert spot-;r t-dlfb
- artidb DM tfTc dd an hbmh AMffWAS E
Stheb 111' 9f MY'>
Zklnofi.dg
.bj.meca aw i
m t k~es My. _i*Vmvdii oi.~fh;'i him id.tt ^I§O l
- -*;etw~~~tr1, lK erih*r'ibbs'eitt f"t-r" ti...... Owi&~so
-^~~~~~~o am
'kinj:
j
- adj,
-hein "Crep sj Withxb2.
t~>%-
AA'.&:w
}~~~~~~~~~~~~-~bztSoal, Do
-4 t4;t;-wd
- X,,State*-. peS, we a" P j%.,
F t.84,il t dI i,
_w.s'...s
.,r,>z at 2
- .<-<.Xri't
.z..9.....
.- -sibs, sivi;
- ,l;-eX,. <,-
a! *0 __e
\\,.'
.l t :<Q: "'.1.;-
- s i C2'd"fXa
+..
I
- . f :':
ia
%;' C i
D
- t;A^
{
C. 'I@@s, go-~
=t; pt I
1',, C, C ?J I ' '.^'^tt i,
e
Al 11-IV AA qB a
_g a
.r 44 0 I N~tO i
T 1 C 0 i
ts8I 0
2,
Ij..-
.. e; J lern4-t iClui o"cm~tf;0 o;
1 ets til tlc
~
rs rtel 1n ecnr.
=
.K-:;
Do
.S
- Sa s
- Lo t
- SO Coot
- -
I si a
R.T.-s-NC Cfclny i
-l Ip: iltt
--8fol -
VW&$
-saioned.T.
N tottrr,,)j iSi Has lM tcri a --
r T..
iI1Y.eil
- 4 s, Sht emoaibllrud; 4
The neig.&t<.
mtraStr bon.of a
remr N
Thk L
~nri rrch rkcth?
t:
lXin Spe. - NieCo rue
'-1
.1 gm
-vns Lon 0
9 D"'Eff*rici e C !l iev omninr fiosreri or Iw c}r.w e
<~,a r
s.1 5-Se HI I
lu R.TP.ue
_s x
t-*~(}MinPeir n
cnt;-
F i
,G tn~d~o optioru cin; N
i H..
r[-R.T.
Ers_:
e.'ms rte If-tt-Heds (a 9M-TubSh rilsg nT.S M(b) iltr~
i n h; rli T.-S gt
-C i-o I n--;
Fl ie
-'.' Mcil Dc It I 1 at- ' -, I r
oncl -
T s lhk; ol-Fiat Si*
Ai taresr Zt bM-
- ecn
- 10 -Tbe IInb O0,
- n Thk-u --
iu "tin orApex An mis N-yp ad_
_u$
If r le ma111 Xanluie bots onltd1rinrhmes°?cee csl used ter~ng fat eninq agr
¢A r
u *^
.pc No.
S
!I*
Number)
Wsi.sc.r'ibwo-r-
-d ss h;. sk t..h).
r -8.`-
- 7. -Jacknt Clsue IF o}-
{ i lt w pcfl}
a,:*
^
tt weld. 'bcfn:
on H
SI_ R a'gv Tie s if bold dE scich ey alSeth
-K b
GirrMinfiT'.
R Peir-Tt
-en-No OI ourt V
tti
- 7 Fls-iig
,Materialkb ltpic C n.eff ic n
.!Aei tshfit encorinir k AlcjDoiarntorn ms
-T k
- 0. 0.
.,E f
i k
in.. or gail'umeTp ge~tti~t;;
ps l
r;>
>rerru r
ht or U)
<¢^
.11-fi
,;i h i:c tltt r'
n iff i i Matrs T3.lX fl I Allow.-tI
- n.
3 tn tf f t In. -Lnt - ft.- jn Wind~le+ pc N'! O-);tfo,,, Imi of rang s E E Soml On .<1_ ffcec
It. slifslvtrvolv Out es*: Nwnif_- outlt ' 116) Nuffiver 14.-. of, Mli Tvp r Avieshall, ', Wt.
- 17.
In~otion Monholft No. lis -ILocatbon -Openings Hanholol: No. lis ;6 Loction-Threaded: No. $1e---Location
- 'l 18 Supports-. Sklirt Lup
.L t -:.Othert Attace~d
- y o~ r no (Nmrrbllr.
lvi~wber) 06VIS 1whosfe flo: w)e*tD}:'; ?it corret a *d. thf ,~*s Is r..ppu...... n,,j "^'-;;We ltify;!ht the ntate tnud MS hirp c °t nthiorp rtnrdrdnt onl t° 0' 4 '(:; X: The a olicable Desi n SPoi iciticti n;n noru not ih rospornsibility'of the'.NPT Conificite'Nodr tot p irts An'NPT Certificase Holoo. 10r4 sopurtenimi s ri1 iooonsiblo -of ]urnithing' s* psrat*7 Des;gn Spic'ifie'itiri andDesign Avport'if'ih*e pp0unv;'-
- t H'
4' e;;nFneIr not incli I the cornpon nt Design ie cton and Design Soport l >J' ! s !,-.' j _,3,, Dole 4 ,19 83 Signed Roc sell Talnl Coro^ .4 a+ .(NPTCrTinflesilsHolder) ljtu r, Qusal tj'ii~~ -C'e1ti-85i,;t*e CoiiicitaB 0'i'Athorizition Mo;; ,,^.. ~CERTIFICATiON OF DESI1iN`FOR APPURTENANC4E (w6*n.&ppliiob10 - i J:t:4X ,*iJ! ^,,;, t Dirignfoernition on file it-Roclcwell jntern4tiona1 > Corv-,i z-ia--ith.'0Nc 27603 -i .. !tv.t!t~,! -1111 ;"-arlit5WUl rlrsnbito ice ROC06 ell;;internatlonal -Qorpi.'. -,Rateijxhv >NQ 2 7 6 03' ';1ti c 'r ,i, &;Iogn 'p cifications ccrtfithdby-8Y ro~ Prof. Eng'Sutot Cal1if Rcg-.Nol36i55 J;;t-* i:.<r,-s sw 4 Tis CERTIFICATE Oi SHOP INSPECTION!F*' '= rt;s 'ho- ,ud i "2ldi avelld commisir', incd
- Vsi, d -by,,Ihc National BoodtB obs ir' A~rlspctorrit Stcor',"w Pfp1n
'riicof XortAt Carolina, -"d '""r b aifployvdi~';j-B 'IC~~lX~b l <^_*et' -:of 'lrdr;'C horve In ~the part of a prissure'vssul dtscribed in this' : Partinal Deis RePort on _le P/ R;s& nd statc that. to the best of rny knowledge -@> fj _ ~ ~ ~ ~ ~~~~~~~~~_'a I ttIt!cNTt~s~lbrttr!rcewh; tn 'iordc wth'thiASM E &de'iiicr I 1;?; , ;; 1t,^ ysig~ning this certitie te,'rnithor thej lnreclor'6iohts inployti~mlikvs Ay wor'ntVep do ph; oannWt: i it> js >>6 '-srbdI thPrilD cotFutnhormortne, r `ith* r'hcinsmetor.nor hli ornfiloyti shill bc Itcbh ~In any mwnno itor-onr poeriiinil' 4 nuryorro itd mvrlnolfnyt hoirisnfror onn eted with thhisnspoctloi ; :t-A . 4r; In::,w Or - .ir da:_ma-g; e-ors 9 Ion of an f A ; t-> s~a-EJ-Corm~ssO;" ' Ag-j°g3-. Ji? iq ts 5
- t i
M.; tt>" TS z.^..w-. U !X tl& or ttr vn e $ S i' 'i 'i',',;S f ' A" A " ~h~'"t z .llotiol .164G ,a,,V'... Ptvic an M.:
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Date 02125104 Sheet I of I Unit I Address Plant LaSalle County Nuclear Station 2. Name 2601 N. 21f Rd. Marseilles. Ii. 61341 (Address) 3. W-4,r 0-F-Arrc h ReAh-*-* RA1lnfnansn-W.O. # 530219-01 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date NIA N v.. (Name) Mechanical Maintenance (Address) 10vM Er-nf-n 0-1, nova 4. 5. l~atlir~ln t ve-n ........I- __.. _. .A (a) Applicable Construction CodeLASME Sect Il 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Appilcable Edition of Section Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Components Repaired or Replaced, and Replacement Components I 7. 8. 9. Description of Work Class I Replacement. = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic IJI Pneumatic II Normal Operating Pressure l X I Other Visual Pressure 1040 asl Test Temp. 165 Deg. F Remarks CRD SN# 8494 was refurbished with documentation Provided under Quality Receipt # 95580 and (Applicable Manufacturer's Data Report to be Attached) Installed as a replacement for SN# 7593A under work order # 530219-01. = Replacement CRD Code of Construction Is ASME Sectlon 111.1971 Ed. S73 & W73 Ad. Reconciled to the original Per PTEs PTE 88.013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of ConstructIon Is ASME Section Ill. Class 1. 1986 Ed. No Ad. Reconciled to the original Code of Construction Per PTE M91-007-0320-01 on file at LaSalle StatIon. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Aut ~aton No. N/A Expiration Date N/A [ISI CoordInator Date 03 , 200A Owner or Owner's Designee, Title 011 7 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LlR09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner foranypersonal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4/ '1i 2L Commissions IL 1927 Ins or's Signature National Board, State, Province, and Endorsements Date 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) Date. 0A4/114A asw TV gave 2. Sheet 1 of I Unit I Wfl # i55289 Repair Organization, P.O. No., Job No., etc. 3. Work Performed by Mechanical Maintenance (Name) Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. 5. 6. (Address) Identification of System (MS) Main Steam (a) Applicable Construction Code ASME Sect. III 19 71 Edition W72 Addenda, Code Cases 1516-1. 1567 (b) Appiicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad. Code Cases N-416-2 Idantifleatinn of Cmronants Renalred or Renlared. and Renlacement Comnonents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced. or Stamped No. Replacement (Yes or No) (1) 3"- Gate Anchor Darling N/A 1821-F019 Replaced NIA Valve Body (1) 3"- Gate Flowserve H1124 N/A UTC # 2687608 1999 Replacement N/A Valve Body Corp. Receipt # 47257 (1) 3" Disc Anchor Darling N/A 1B21-F019 Replaced N/A Assembly (1) 3" Disc Flowserve 21201-1-3 N/A UTC # 2686422 2003 Replacement N/A Assembly Corp. and Receipt # 95531 1_ 21201-1-4
- 7.
Description of Work: Class I Replacement * = Per N-5 Code Data Renort on file at LaSalle County Station.
- 8.
Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure IX I Other Visual Pressure 1040 osl Test Temp.j165 Deg. F
- 9.
Remarks: Revlaced valve body and disc assembly with new like for like components due to valve leakina by. (Applicable Manufacturer's Data Report to be Attached) CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificauthor on No. N/A Expiration Date SIlnned 6 K °4ZA ISI Coordinator Dat N/A te At Z/-Z . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issuedby the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. IAJ 14f4 1v7 Commissions IL 1927 Aector's Signature National Board, State, Province, and Endorsements Date ____ 2004_
95531 FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES* As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg.. 1 of 2
- 1. Manufactured and certified by Flowserve Corporation, 1900 S. Saunders St., Raleigh, NC 27603 Mname and address of NPT Ceflificate Holder)
- 2. Manufactured for Exelon Generation Co., LLC, P. 0. Box 805388, Chicago, IL 60680 Iname and address of purchaser)
- 3. octio o intalaton Exelon Generation CO.; LLC, LaSalle Station, Marseilles, IL 61341 Location of installation ame and address) 4 W9424337,R/E SA182,F5A N/A N/A 2003 Type (drawing no.)
Imatl. spec. no.) ftensile strength) (CRN) (year built)
- 5. ASME Code, Section Ill, Division 1:
1971 Winter, 1972 1 1516-1 (edition) (addenda date) Iclass) (COde Cae no.)
- 6. Fabricated In accordance with Const. Spec. (Div. 2 only)
N/A Revision N/A Date N/A (no.)
- 7. Remarks:
Disk assembly for 3" 9001 Gate Valve S. 0. 26991
- 8. Nom. thickness (in.)
N/A Min. design thickness (in.) Per #4 Dia. ID (ft & in.) N/A
- 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:
Length overall (ft & in.) N/A
- 1 Part or Appurtenance Serial Number National Board No.
In Numerical Order 21201-1-3 N/A X (2) 21201-1-4 N/A (3) (4) (5) (6) (7) (8) (9) 10)I (11)- (12) (13)- (14) - 115) - (16) (171 0s8} (19)- (26fW'. (21) - M7v1 National Part or Appurtenance Board No. Serial Number In Numerical Order. - (26) (27) (28) 129) (30) (31) (32) (33) (34) (35) (36) (37) (38) (39) (40) (411 (42) (43) (44) (45) (46) (47) (48) (49) (50) -s (23) (24) (25) I
- 10. Design pressure 1714 Psi.
Temp. 5F Hydro. test pressure N/A at temp. F (when applicable)
- Supplemental information In the form of lists. sketches, or drawings may be used provided 11) size Is 81/1 x 11, (2) Information In items 2 and 3 on this Data Report is included on each sheet. (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(7/98) This form (E00040) may be obtained from the Order Dcpt., ASME, 22 Law Drive. Box 2300, Fairfield, NJ 07007-2300.
9 5 5.3 1 FORM N-2 (Back - Pg 2 of 2 1 Certificate Holder's Serial Nos. 21201-1-3 through 21201-14 CERTIFICATION OF DESIGN Design specifications certified by (when applicable) P.E. State Reg. no. Design report* certified by (when applicable) P.E. State Reg. no. CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these)* Part(s) conforms to the rules of construction of the ASME Code, Section III, Division 1. NPT Certificate of Authorization No. N-1563 Expires November 26, 2006. Date 1_2J_-_ _(_4_ Name Flowserve Corporation Signed INPT Certiicate Holder) lSuleorided representalive) CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North CaroliL and employed by H5SR CT of Hartford. CT have inspected these Items described in this Data Report on , and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section ll, Division 1. Each part listed has been authorized for stamping on the date shown above. By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this Inspection. Date Signed n (Aulhorized Nuclear InspectorT Commissions INatl.
- d. (incl. endorsementsi and stale or prov. and no.1
FOrCK 1NI NT CU1t=CATZ UOLD A DATA RaMOT roa muc~xA PART AmD AtwT~cuxrs. As M~tirW by the Pguvs~e df l ASME CaU KnieL Sectim Ill. Div. I 1 agmaiudyFlowioerve Corp., 701 First Street, WillJiamisport, PA 17701 L (a) Umdaucass d ()inmIVmfComIonwojalth rdlean Eo~ . Q. 1gr 767. Chicago. rL 60690 M -uM(9wmmUfni mnw L0~a f~~f3515 ~ f1124 UsRI~NA (a) CasummIeW AacmiSdl w Deeming C224~ RAt onermlg pmwe.d rj fowserve Corp. (b) D4esewgam e1 pSI I**pniaed Body w'/Seat Rings Heat: *L77 SA 217-CS
- j. RadAs:as Scare Part~s) for 900 4 DD GateVa Ive NJOTE:
Ndo Hydrotestinlq Performed LRSALLE NUCLEAR ST hTIOw toer meis ml.. d ofemeaeta.1 VsA512Cad 4s..m Pe 1uK*
- s.
f"~m~fb
- dfe i
h ag ewr-i____ be wtmmsig' i Smig AMAC 0a......JQ..2L.,.S. S..4 Flovserve Corp. Ceriracme of Ahmlbm~ime Zzpirw 4/l5#'0l AnweJ w 1,46 f1713 CERflFICAflON OF DESCI FRif APPURTENANCE ('.& e.pplicm~e) Desipe Wermesaame Mell Dewi.. spectrcaftesa Cwfrtarsd ljFs.E 5 Sse........lg CERTIFCATE OF SHOP VISPECTIOC tl. d-maderigmed, howwag a cow-
- aass id by se Maimeel.sald of B~auer sd Poeewc V~essel Aepectst
~.ds5...~f Pnnsylvania m,4wl,,b,-Cornrcia1 Union Insurance Comoan) BostgnauKass. Am a BSw. wPno a FMesese stee desrie is this parwvot Ran Mex~. UN, A1 ft m bern ofmy knowIkg SaW bellef. SellMr CCwUfUeU Holier baa CQUORIN 0su Me CWM M. AS"~ Cad.Se~. 3*U lag the panl demlbod Ia1MU ftunie Data Raevew Fuia~rtbsre. aeitui the bSpewf~ Mns Nog 0091ret Vickn t a...* -i ~, L -w Thi fry~ sW~b.s Ghe obasla. Mu *ae 0 ss, a 4 Ii. a MNTIUI
FROM H42 (bicl items 4-I Jorl. is be e..eI.'.d la* giggle Weji seesa0.is. e.bef of jack mail". Sconese. 1.at1 LT..KT. ' J,. A -RI e,, 1. ,.
- . _
- I ' -_'- ; ;,- -, -7 .r. I -4 ,; t;, " 4_ 9LS-I? k) lid eve mul a. W et Uhls Wf&eu e-*saba._4 1_W-at 0 I S t i.R Gish ____H.T.' LT. M41...1 COWe* a________ W*I~d a MTr*________ .5 Cb) Maeeuiaj T______ 15 &m00Com .upwue EUWI4"e CoaeeL kaaa' via to~g Pne (Too. Oessa. mode 'IW.3w4. Rabsis 3*4*& a3MW A* AAm14 (Cam. W., (M...e e............ M~- 0""0 .om .44.3. 11111 3.S90t" 4meme. W atesi e "Wu"
- 7. Jacket Closftw
- 3. 0*0e8* presam A: -
Omp wishe _IF__ s up. of or Items9 ead'1 Rssa be ors~geved le ftbe sectiems
- 10. Tube.
Umermelr 0.0.wy A M... T Mmbses-it A TVisir tOn. or in Items 11-14 isad. so be cea~1.,d Amt smew "abeirs of jiebstiado 9"sds. Or eb4emRS of hemt eC*ba-#er. t-1 X _j _- 6 CD I I. S h e l l : a e s T i h e e.... I. m e... e... ,. i. a ' .. L
- 32.
Se am : Less S LT. '_ L Y. E ftsciincp G.Y.'OLT. .4 deofC m.,ee I3. Hirads 4a) m4ace"i T.S. MSMemeial T.S._ Lpain Tuat e a mi Nadine Valve AO"4 AAWSR1,. Da (COW..9 mr (a) T.P. betoa&.. eadse_ (b) Chanssa_ It rem o eable. b ea s a eed.(h( ) __ _ _ _ _O e £a e u g t Oe s i n. o r .e se Diep Weislot 14 iss rsn ,Cheepy impact (44b 1. D s g p e a a ep s i W _ _ m9 O 4 " h. o f to be comieirsstlow au vesst "Netw apptawafe. , Valve O ets: N mb Size______ Lecatina lasmumm T hUM n.... Stv., ^4atsi*. Pusane 0... et Siec TV". to. S..ppw s: Shifut ~ ~Lvov Less A ac hqibd t P e. e0- e l a.....
- L. I *41n.
W 06f"
- 01" GO S@
-*a q@minemq*R& si~mw,.R ,e f44eo
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Fwelon Generation Comnanv (FGCI LLC Date 02118/04 (Name) 200 Exelon Wav. Kenneth Sauare. PA.. 19348 Address Plant LaSalle County Nuclear Station Sheet 1 of 1 Unit 1 2. Name 2601 N. 21t Rd. Marseilles. II. 61341 (Address) W.O. # 557248-01 Repair Organization, P.O. No., Job No., etc. 3. Work Performed I.. &A-1-nl-n 2A.16 -- - (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date NIA 4. 5. 6. Identificatlon of System (RD) Control Rod Drive (a) Applicable Construction Code-ASME Sect iII 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-j989, No Ad, Code Cases None Identification of Components Repalred or Replaced. and Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Bulit Replaced, or Stamped No. I _IReplacement (Yes or No) CRD Assembly G.E. 9178 N/A 34-51 Replaced NIA CRD Assembly G.E. A990 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 34-51 Replaced N/A (7) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 90242 2003 Replacement N/A C 192 (1) CRD Capscrews Nova Ht. # 828901Lot NIA Receipt # 72558 2001 1 Replacement NIA
- 40042711 7.
8. 9. Description of Work Class 1 Replacement. * = Per N-5 Code Data Report on file at LaSalle Countv Station. Tests Conducted: Hydrostatic I I Pneumatic II Normal Operating Pressure I X I Other Visual Pressure 1040 os1 Test Temp. 165 Deg. F Remarks CRD SN# A990 was refurbished with documentation provided under Quality Recelit # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 9178 under work order #557248-01. = Re[lacement CRD Code of Construction Is ASME Section 111.1971 Ed. 573 & W73 Ad. Reconciled to the original ver PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section Iil. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A qSnalaed go ISI Coordinator D nat 9O7L /c;;0 in200 Owner or Owner's Designee, Title u.- - -7_, - CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of lliinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described in this Owner's Report during the period Li R09 to LI R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 2 4 Commissions IL 1927 Insottor's Signature National Board, State, Province, and Endorsements Date a 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA.. 19348 Address Plant LaSalle County Nuclear Station Date 021 tin Sheet I of 1 Unit 1 2. Name 2601_N..1' R. Mrels. _L...._. __...1 (Address) W.O. # 557249-01 Repair Organization, P.O. No., Job No., etc. 3. Wnrk Perfnrmed hi Manhninlenl MnInfanant-a ..w.n., (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Auithnrizafinn Nno NIA Expiration Date NIA 4. 5. Identification of System (RD) Control Rod Drive (a) Appiicable Construction CodeASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad, Code Cases None Identification of Comoonents Reoalred or Replaced. and Replacement Components 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9538 N/A 58-27 Replaced N/A CRD Assembly G.E. 9510 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 58-27 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 90242 2003 Replacement N/A _ _ _ _ _ _ _C 19 2 I_ 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Reoort on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic II Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks CRD SN# 9510 was refurbished with documentation provided under Quality Recelit # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 9538 under work order # 557249401. ** = Reolacement CRD Code of Construction Is ASME Section 111. 1971 Ed. S73 & W73 Ad. Reconciled to the origlnal ver PTEs PTE 884013 & PTE 88-396 on file at LaSalle Station. Replacement Canscrew Code of Construction Is ASME Section Ill. Class 1. 1986 Ed. No Ad. Reconciled to the orialnal Code of Construction ver PTE M91-007.0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xi. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed c2 u rE ta-e* ISI Coordinator Date O/ . 2004 Owner or Owner's Designee, Title / / CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insy. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to L RI10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 4. 1. Z4i41. Commissions IL 1927 Inspetor's Signature National Board, State, Province, and Endorsements Date .9 .. 2 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companv (EGCI LLC (Name) 200 Exelon Way. Kenneth Sauare. PA.. 19348 Address Plant LaSalle County Nuclear Station Date 02118/04 Sheet 1 of I Unit 1 2. Name 2601 N. 21" Rd. Marseilles. 11. 61341 (Address) W f A 997'25nAn1 ws.v. w U^^ouou Repair Organization, P.O. No., Job No., etc. 3. tWf-lO 1A4-BLI s UAMhnl-s IVuPIr I (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Authorization No. NIA Expiration Date. NIA 4. S. Identification of System (RD) Control Rod Drive (a) Applicable Construction CodeASME Sect liM 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Editlon of Section Xl Utilized for Repairs or Replacements-1989 No Ad, Code Cases None IdentificatIon of Comoonents Renalred or Replaced, and Reolacement ComDonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 6628 N/A 54-31 Replaced N/A CRD Assembly G.E. A8585 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova NIA54-31 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code NIA Receipt # 90242 2003 Replacement N/A _ _ _ _ _ _C 192 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic II__1 Pneumatic I l Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks CRD SN# A8585 was refurbished with documentation Provided under Quality Recelpt # 95580 and (Applicable Manufacturer's Data Report to be Attached) Installed as a replacement for SN# 6628 under work order # 557250-01. ** = Replacement CRD Code of Construction Is ASME Section 111.1971 Ed. S73 & W73 Ad. Reconciled to the original Per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Canscrew Code of Construction Is ASME Section Iil. Class 1. 1986 Ed. No Ad. Reconciled to the original Code of Construction Per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Au atlon No. NIA Expiration Date NIA Slgn* isi Coordinator Date OX /, -e/ . 2004 Owner or Owner's Designee, Title / / CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L1R09 to -LJR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. A 4Commissions IL 1927 Inspectr's Signature NationalBoard, State, Province, and Endorsements Date dc -2 2004
FORM NIS.2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. 2. Owner Exelon Generation Comrany (EGC) LLC (Name) 200 Exelon Way. Kenneth Sauare. PA., 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21t Rd. Marseilles. II. 61341 (Address) Date A, In Sheet 1 of I Unit 1 W.O. # 557251-01 02/1 RinA 3. Work Performed I.. U^1-- -slo -~"na~ Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A vy Me,, llulI Il IIlI Pd I (Name) Mechanical Maintenance (Address) 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction CodeASME Sect iII 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Comnonents Reoalred or Renlaced. and Reolacement Comoonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9224 N/A 58-39 Replaced N/A CRD Assembly G.E. 7640 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova NIA 58-39 Replaced N/A (7) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 90242 2003 Replacement N/A _C192 (1) CRD Capscrew Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A _ _ _ _ _ _H 6 4 6_ 8. 9. Description of Work Class 1 Replacement. -= Per N-5 Code Data Revort on file at LaSalle County Station. Tests Conducted: Hydrostatic l I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks CRD SN# 7640 was refurbished with documentation orovided under Quality Recelit # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 9224 underwork order # 557251-01. = Replacement CRD Code of Construction Is ASME Section 111. 1971 Ed. 573 & W73 Ad. Reconciled to the oriqinal per PTEs PTE 884013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section lii. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction oer PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authortz on No. N/A Expiration Date N/A Slanedenl: < e A ISI Coordinator Date 6a /v+4eL / . 2004 Owne'r or Owner's Designee, Title -7 _ CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIRIQ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Impiled, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. /O 4
- 7J j Commissions IL 1927 InsivJtor's Signature National Board, State, Province, and Endorsements Date A
- ;2sY 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Date 02)18104 Sheet 1 of I Unit I 2. Name 2601 N. 2."t Rd. Marseilles. II. 61341 (Address) W.O. # 557252-01 Repair Organization, P.O. No., Job No., etc. 3. IAIrlT D1k..erlh amInl &s - - - - - -^ wIFU5n IrenoIAW11u "y Msala aneac (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A 4. 5. 6. Identification of System (RD) Control Rod Drive (a) Applicable Construction Code ASME Sect III 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Comoonents Reoalred or Replaced, and Reolacement Comoonents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9420 N/A 54-43 l Replaced N/A CRD Assembly G.E. 8544 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova e N/A54-43 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A _ _ _ _ _H 6 4 6 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic IIJ Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osI Test Temp. 165 Deg. F Remarks CRD SN# 8544 was refurbished with documentation Provided under Quality Recelot # 95580 and (Appilcable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 9420 under work order # 557252-01. = Reolacement CRD Code of Construction Is ASME Section Ill. 1971 Ed. S73 & W73 Ad. Reconciled to the orloinal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Canscrew Code of Construction Is ASME Section 1i1. Class 1. 1986 Ed. No Ad. Reconciled to the original Code of Construction per PTE M91.007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this - Replacement conforms to the rules of the ASME Code, Section XI. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authoriz tion No. N/A Expiration Date N/A Signed el,. ISI Coordinator Date 0 . 2004 Owner or Owner's Designee, Title I .4 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to L1R110 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 j 78t V? Commissions IL 1927 Inspect VI Signature National Board, State, Province, and Endorsements Date A2 S -2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Sauare. PA.. 19348 Address Plant LaSalle County Nuclear Station Date 02/18104 Sheet I of I Unit I 2. Name 2601 N. 21* Rd. Marseilles. II. 61341 (Address) W.O. # 557253-01 3. Work Performed kv h .nken M t.n.n Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A u vxWWwa.S (Name) I1AP~ Ii 9III --l------ (Address) 4. 5. Identification of System - (RD) Control Rod Drive (a) Applicable Construction Code ASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) AppilcableEditionofSectlonXIlUtilizedforRepairsorReplacements-1989 No Ad, Code Cases None Idnntifieatlnn of Cnmnnnonntf Rpnalred or Renlated-and Rniaarnement onmnnnnente Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Bulit Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 7908 N/A 50-47 Replaced N/A CRD Assembly G.E. 7661 N/A Receipt # 95580 2004 Replacement N/A (8) CR0 Capscrews Nova N/A 50-47 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A H~1-6 4 6_ 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic l I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 asl Test Temp. 165 Deg. F Remarks CRD SN# 7661 was refurbished with documentation provided under Qualitv Recelpt # 95580 and (Applicable Manufacturees Data Report to be Attached ) Installed as a replacement for SN# 7908 under work order # 557253-01. = Replacement CRD Code of Construction Is ASME Section 111.1971 Ed. S73 & W73 Ad. Reconciled to the orialnal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Caescrew Code of Construction Is ASME Section 1i1. Class 1.1986 Ed. No Ad. Reconciled to the orlainal Code of Construction oer PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Reolacement conforms to the rules of the ASME Code, Section XI. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Satn:' e ISI Coordinator Date _
- 2. ZX 5er //
. 2004 Owner or Owner's Designee, Title .1 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L1-R09 to LR-10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions IL 1927 Iniector's Signature National Board, State, Province, and Endorsements Date IZ: 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Date 0V218/IA Sheet 1 of I Unit I 2. Name 2601 N. 21"t Rd. Marseilles. II. 61341 (Address) W.O. # 557254-01 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorizatlon No. NIA 3. wa#it. D J A U. 111hl-t - - VWVFrI Irag jnlo5meu Si MU1110151dica IT0l Ia1dI hUe IaO (Name) Mechanical Maintenance (Address) Expiration Date. N/A 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction CodeASME Sect ill 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Editon of SectIon Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Comnonents Renalred or Reolaced. and Reolacement Comnonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repalred ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 5286 N/A 46-51 Replaced N/A CRD Assembly G.E. A8529 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 46-51 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Recelpt# 93916 2003 Replacement N/A _ _ _ _ _ _ _H 6 4 6_ 7. 8. 9. Description of Work Class I Replacement. ^ = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osi Test Temp. 165 Deg. F Remarks CRD SN# A8529 was refurbished with documentation provided under Quality Receint # 95580 and (Appilcable Manufacturer's Data Report to be Attached) Installed as a replacement for SN# 5286 under work order # 557254401. - = Replacement CRD Code of Construction Is ASME Section 1I1. 1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section Ill. Class 1.1986 Ed. No Ad. Reconciled to the original Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Author tion No. N/A Expiration Date N/A Signed 5E ec oe L1 ISI Coordinator Date 40 no . 2004 Owner or Owner's Designee, Title / CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issuedby the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kd arising from or connected with this Inspection. '4 71 Commissions IL 1927 Vpector's Signature National Board, State, Province, and Endorsements Date A - A S - 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner Exelon Generation Comoanv IEGCI LLC (Name) 200 Exelon Way. Kenneth Scuare. PA., 19348 Address Plant LaSalle County Nuclear Station DateI nwlixInA C At. Sheet I of 1 Unit I 2. Name 2601 N. 21' Rd. Marseilles. II, 61341 (Address) W.O. # 557255-01 3. Work Performed by_ Mechanical Maintenance Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp NIA Authorization No. NIA Expiration Date N/A (Name) Mechanical Maintenance (Address) 4. 5. A Identification of System (RD) Control Rod Drive (a) Applicable Construction Code-ASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) ApplIcable EdlUon of Section Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None IdeanntflcatInn of r-mnnnentn Rnnaired or Ranlanpd-and Rpniactment Cmrnnnonntf Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped l No. Replacement (s or No) CRD Assembly G.E. 7538 NIA 42.07 Replaced N/A CRD Assembly G.E. 6788 N/A Receipt # 74388 2002 Replacement N/A (8) CRD Capscrews Nova N/A 42-07 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Recelpt #93916 2003 Replacement N/A _ _ _ _ _ _ _H 6 4 6 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I.I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osi Test Temp._ 165 Deg. F Remarks CRD SN# 6788 was refurbished with documentation orovided under Quality Recelpt # 74388 and (Applicable Manufacturers Data Report to be Attached) Installed as a replacement for SN# 7538 under work order # 557255-01. = Replacement CRD Code of Construction Is ASME Section 1i1. 1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Canscrew Code of Construction Is ASME Section il. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction oer PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed i~ ISI Coordinator Date 0;7 / 2004 Owner or Owners Designee, Title Z / CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Ilinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIRO9 to 1-R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Z4 k42 Commissions IL 1927 Insp r's Signature National Board, State, Province, and Endorsements Date 20 Date d-~ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA., 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21'" Rd. Marseilles. II. 61341 (Address) Date 02/19104 Sheet 1 of I Unit I 2. W.O. # 557256-01 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp NIA Authorization No. N/A 3. Work Performed by_ Mechanical Maintenance (Name) Mechanical Maintenance (Address) Expiration Date NIA 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction Code.ASME Sect iII 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repalrs or Replacements-1989, No Ad, Code Cases None Idantfi,-ratinn of rnmnnnonnts Renalred or Rpnlaced-and Renl~acment Cnmnonnntf Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Bulit Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9542 N/A 42-03 Replaced N/A CRD Assembly G.E. 7535 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 42-03 Replaced NIA (8) CRD Capscrews Nova Ht. Trace Code N/A Recelpt # 93916 2003 Replacement N/A H 646 I"__ 7. 8. Description of Work Class I Replacement. I = Per N-5 Code Data Revort on file at LaSalle County Station. Tests Conducted: Hydrostatic I IJ Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks CRD SN# 7535 was refurbished with documentation provided under Quality Recelot # 95580 and 9. (Applicable Manufacturer's Data Report to be Attached ) InstalledI as a ranlemon$ for SM 9542 under. work ordeor # 557256-01.** = Raneomrnt nfRn Code of Construction Is ASME Section III. 1971 Ed. S73 & W73 Ad. Reconciled to the origlnal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section lil. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction oer PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Sinned ISI Coordinator Date e 2s f g . 2004 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller lnsp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to LR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. k.. 4 < /.7AL Commissions IL 1927 Inspe mr's Signature National Board, State, Province, and Endorsements Date
- -;2%56 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) Date 02/19104 2. Sheet 1 of 1 Unit 1 Wnl it 557257.-1 3. Work Performed by_ Mechanical Maintenance Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. NIA Expiration Date NIA (Name) Mechanical Maintenance (Address) 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction CodeASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements-1989, No Ad, Code Cases None Identfilcatlon of Comnonents Renalred or Renlaced. and Reolacemnent Comnonents 6-Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Bulit Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9384 N/A 30-11 Replaced N/A CRD Assembly G.E. 7812 NIA Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A30-11 Replaced NIA (8) CRD Capscrews Nova Ht. TraceCode N/A Receipt # 93916 2003 Replacement N/A H 646 I_ 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osi Test Temp. 165 Deg. F Remarks CRD SN# 7812 was refurbished with documentation provided under Qualitv Receipt # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 9384 under work order # 557257-01. = Replacement CRD Code of Construction Is ASME Section Ill. 1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section lii. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction ner PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xi. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Sioned Ae.e c ISI Coordinator Date Ode a I9r /, 2004 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have inspected the components described in this Owner's Report during the period LI R09 to LIR10 I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty,expressed or Implied, concerning the examinations and corrective measures described In this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 24 iI. T4L. Commissions IL 1927 Insottor's Signature National Board, State, Province, and Endorsements Date A - -IS 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Date n2191§04 Sheet. 1 of I Unit 1 2. Name 2601 N. 21'4 Rd. Marseilles. II. 61341 (Address) W.O. # 557258-01 Repair Organization, P.O. No., Job No., etc. 3. Work Performed by AZ Mechanical Maintenance (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp N/A Authorization No. NIA Expiration Date N/A 4. 5. IlUVIIL1IIlIUI1I UL e MAUIwomrol nou unvw (a) Applicable Construction Code-ASME Sect iII 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utliized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Comoonents Renalred or Reclaced. and Reolacement Components 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 7742 N/A 22-27 Replaced N/A CRD Assembly G.E. 8536 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 22-27 Replaced NIA (7) CRD Capscrews Nova Ht. Trace Code N/A Receipt# 93916 2003 Replacement N/A _ _ _ _ _ _H 646_ (1) CRD Capscrew Nova Ht. # 82890/Lot N/A Receipt # 72558 2001 Replacement NIA 40042711 I 7. 8. 9. Description of Work Class 1 Replacement. * = Per N-5 Code Data Recort on file at LaSalle County Station. Tests Conducted: Hydrostatic L I Pneumatic LI Normal Operating Pressure I X I Other Visual Pressure 1040 osi Test Temp. 165 Deg. F Remarks CRD SN# 8536 was refurbished with documentation orovided under Qualitv Recelt # 95580 and (Applicable Manufacturers Data Report to be Attached ) Installed as a reolacement for SN# 7742 under work order # 557258-01. *- = Renlacement CRD Code of Construction Is ASME Section Ill. 1971 Ed. S73 & W73 Ad. Reconciled to the orlainal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Reolacement Caoscrew Code of Construction Is ASME Section lii. Class 1. 1986 Ed. No Ad. Reconciled to the orialnal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A Signed d2 ISI Coordinator Date Ir . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to 1-R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any klnd~prlsing from or connected with this Inspection. Commissions IL 1927 Itpector's Signature National Board, State, Province, and Endorsements Date 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Date 0211 Q/O Sheet I of I Unit I 2. Name 2601 N. 21" Rd. Marseilles. ii. 61341 (Address) W.O. # 557259-01 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Auithnrizftinn No. NIA 3. Work Performed bV Rgechannlf-Ra21nfeancen (Name) Mechanical Maintenance (Address) Exnlratlon Date NIA 4. S. Identification of System (RD) Control Rod Drive (a) Applicable Construction CodeASME Sect Ili 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad, Code Cases None Identification of Comnonents Renalred or Replaced, and Reolacement Components 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. A936 N/A 14-55 Replaced N/A CRD Assembly G.E. 7890 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A14-55 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A _ _ _ _ _H 6 4 6 7. 8. 9. Description of Work Class 1 Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic _I Normal Operating Pressure I X I Other Visual Pressure 1040 tsl Test Temp. 165 Deg. F Remarks CRD SN# 7890 was refurbished with documentation Provided under Qualitv Receipt # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# A936 under work order # 557259-01. - = Reoiacement CRD Code of Construction Is ASME Section fit. 1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section Iil. Class 1. 1986 Ed. No Ad. Reconciled to the oriainal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Renlacement conforms to the rules of the ASME Code, Section Xi. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A SIgned5::
- e.
ISI Coordinator Date 2 /2EZ* . 2004 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insy. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to 1-RI10O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. '2H.1 A gC Commissions IL 1927 I ~ector's Signature National Board, State, Province, and Endorsements Date Oq f%, 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Comoanv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21s" Rd. Marseilles. II. 61341 (Address) Date n021innA 2. Sheet 1 of I Unit I W.O. # 557260-01 Repair Organization, P.O. No., Job No., etc. 3. Work Performed hv Mechanticl Mln$nfannegs (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Authorization No. NIA Expiration Date NIA 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction Code-ASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repalrs or Replacements-1989. No Ad, Code Cases None Idnn*iflentlnn nf P-nmn.nnnte Dnnslrs.4 -, Ca-ds-A enA 0-n1--amanf nmnnnfn.* r; Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9330 N/A 10-43 Replaced NIA CRD Assembly G.E. 7539A N/A Receipt # 95580 2004 Replacement NIA (8) CRD Capscrews Nova N/A 10-43 Replaced N/A (8) CRD Capscrews Nova Ht. TraceCode NIA Receipt # 93916 2003 Replacement N/A H 646 I_ 7. 8. 9. Description of Work Class I Reglacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic il1 Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks CRD SN# 7539A was refurbished with documentation provided under Quality Recelot # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a reofacement for SN# 9330 underwork order #557260-01. -- = Replacement CRD Code of Construction Is ASME Section i11.1971 Ed. S73 & W73 Ad. Reconciled to the orlaInal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Canscrew Code of Constructlon Is ASME Section ill. Class 1.1986 Ed. No Ad. Reconciled to the orlainal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA Signed G C / ISI Coordinator Date aZ/Z4 / . 2004 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have inspected the components described In this Owner's Report during the period LI R09 to LJR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind risinp from or connected with this Inspection. &l 1Commissions IL 1927 In¶19ctor's Signature NationalBoard, State, Province, and Endorsements Date A -2,A-2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner Exelon Generation Companv (EGC1 LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station DateI n(j*1'AA S vztv-. Sheet 1 of I Unit 1 2. Name 2601 N. 21st Rd. Marseilles. II. 61341 (Address) W.O. # 557261-01 3. Work Performed by_ lel4-6lf8r-tl- -f 0-<:ta Mechanical Maintenance (Name) Mechanical Maintenance (Address) r1nM t 0-tr r%.nr nav Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp NIA Authorization No. NIA Expiration Date N/A 4. 5. A (a) Applicable Construction Code-ASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Appilcable Edition of Section Xl Utilized for Repalrs or Replacements-1989 No Ad, Code Cases None Idtsntftfitfinn nf onmnnnnents Reannred nr Renlaaed. and Repna,'ement onmnnnentf v.~--. -ZE ~ sa ve _V@M~ ~ shiv________ Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 6696 NIA 06-23 Replaced N/A CRD Assembly G.E. 9324 N/A Receipt # 74388 2002 Replacement NIA (8) CRD Capscrews Nova N/A 06-23 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement NIA H 646 I_ 7. 8. 9. Description of Work Class I Reolacement. * = Per N-5 Code Data Renort on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I _ I Normal Operating Pressure I X I Other Visual Pressure 1040 psi Test Temp. 165 Deg. F Remarks CRD SN# 9324 was refurbished with documentation orovided under Quality Recelit # 74388 and (Applicable Manufacturer's Data Report to be Attached) Installed as a reolacement for SN# 6696 under work order # 557261-01. *- = Replacement CRD Code of Construction Is ASME Section i11.1971 Ed. S73 & W73 Ad. Reconciled to the orlainal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section lil. Class 1. 1986 Ed. No Ad. Reconciled to the orlalnal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of AuthortzNtlon No. N/A Expiration Date NIA Sinned 4 10 c-e, ISI Coordinator Date P3/,a,/ - 2004 Owner or Owner's Designee, Title / CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insy. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period 1IR09 to LIRIO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. ki,JA1 2Jkt Commissions IL 1927 Inspe r's Signature National Board, State, Province, and Endorsements Date
- 5 S>
2004 II
==U
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner Exelon Generation Companv (EGCI LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Date 02123/04 Address Plant LaSalle County Nuclear Station Sheet I of I Unit I 2. Name 2601 N. 2l" Rd. Marselilles. II. 61341 W.O. # 557262.01 (Address) 3. Work Performed by Mechanical Maintenance Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A (Name) Mechanical Maintenance (Addrass) 4. 5. AR Identification of System (RD) Control Rod Drive (a) Appilcable Construction CodeqASME Sect iII 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repalrs or Replacements-1989, No Ad, Code Cases None IdentifiratIon of Conmnnnonts Renalrrd or Rpnlaned[ and R~ntaeiPant Cnom nnnnntr Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9546 N/A 02-27 Replaced NIA CRD Assembly G.E. 8475 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 02-27 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement NIA H 6 4 1 I_ 8. 9. Description of Work Class I Replacement. ^ = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic l..J Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osi Test Temp. 165 Deg. F Remarks CRD SN# 8475 was refurbished with documentation provided under Quality Recelit # 95580 and (Applicable Manufacturer's Data Report to be Attached) Installed as a replacement for SN# 9546 under work order # 557262-01. = Replacement CRD Code of Construction Is ASME Section Ill. 1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 884013 & PTE 88-396 on file at LaSalle Station. Replacement Caoscrew Code of Construction Is ASME Section I11. Class 1. 1986 Ed. No Ad. Reconciled to the original Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Autho atlon No. N/A Expiration Date N/A Signed c ISI Coordinator Date tv /^?. 2004 Owner or Owner's Designee, Title 0 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to
- LIR10, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Agv../. i 2Lh2 Commissions IL 1927 Inspec s Signature National Board, State, Province, and Endorsements Date I -
- 2. {2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way, Kenneth Sguare. PA., 19348 Address Plant LaSalle County Nuclear Station Date 02/23104 Sheet 1 of I Unit I W.O. # 557263-01 2. Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) 3. Work Performed by Mechanical Maintenance Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A (Name) Mechanical Maintenance (Address) 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction CodeASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad, Code Cases None Identification of Components Reoalred or Replaced. and Replacement Comoonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 7904 NIA 54-39 Replaced N/A CRD Assembly G.E. 7665 NIA Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 54-39 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 203 Replacement NIA _ _ _ _ _ _H 64 6_ 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Reoort on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 Dsl Test Temp. 165 Deg. F Remarks CRD SN# 7665 was refurbished with documentation provided under Quality Receipt # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 7904 under work order # 557263401. = Replacement CRD Code of Construction Is ASME Section Il1. 1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Cavscrew Code of Construction Is ASME Section ill. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Renlacement conforms to the rules of the ASME Code, Section Xi. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Slgned n4. e< t 1 ISI Coordinator Date '2 /S . 2004 Owner or Owner's Designee, Title Ie CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to LIRIO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 24Z../, 4 Commissions IL 1927 Ins 27 or's Signature National Board, State, Province, and Endorsements Date _ _2_ _ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. 2. Owner Exelon Generation Companv (EGC) LIC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) Sheet I of I Unit I W.O. # 557264.01 Date 02123/04 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Anthnrmaflnn Mno NIA 3. Wnrk Perfnrmied hi MUahannInlal Mlintnnanoe-Covers z I (Name) Mechanical Maintenance (Address) Exnlratlon Date NIA r 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction Code ASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361.2 (b) Applicable Edition of Section Xl Utilized for Repalrs or Replacements-1989. No Ad, Code Cases None Identification of Components Renalred or Replaced. and Renlacement Components 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Bulit Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 7472 NIA 50-39 Replaced N/A CRD Assembly G.E. A982 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 50-39 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A _ _ _ _ _ _ _H 6 4 6 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic 1I I. Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osi Test Temp. 165 Deg. F Remarks CRD SN# A982 was refurbished with documentation provided under Quality Receipt # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a reolacement for SN# 7472 under work order# 557264-01. " = Reolacement CRD Code of Construction Is ASME Section 111.1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section ill. Class 1. 1986 Ed. No Ad. Reconciled to the oralanal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section XI. (repair or replacem Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date Signed C / 5fC4 ISI Coordinator Date O4, Owner or Owner's Designee, Title _conforms to the rules ent) N/A
- /d-2004 CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issuedby the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period I1 R09 to 1R110 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 4 Commissions IL 1927 Insperes Signature NationalBoard, State, Province, and Endorsements Date 2 - V.<. 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Companvy EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 215" Rd. Marseilles. II. 61341 (Address) neont nkft1%nmn WOWe UVl& Jr 2. Sheet 1 of I Unit I W.O. # 557265-01 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp NIA Athnrmatlnn No. NIA 3. Work Performed b%I Morhanleal Malntanantce (Name) Mechanical Maintenance (Address) Exnlratlon Date NIA 4. 5. r, Identification of System (RD) Control Rod Drive (a) Applicable Construction Code ASME Sect ill 19 71 Edition No Addenda, Code Cases 1361-1. & 1361.2 (b) Applicable Edition of Section Xi Utilized for Repalrs or Replacements-1989. No Ad, Code Cases None Identifltaf[on of Comnonents Renaired or Renlaced. and Renlacement Comoonents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Bulit Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 6713 NIA 50-31 Replaced NIA CRD Assembly G.E. 8476 NIA Receipt # 95580 2004 Replacement NIA (8) CRD Capscrews Nova NIA 50-31 Replaced NIA (8) CRD Capscrews Nova Ht. Trace Code NIA Receipt # 93916 2003 Replacement N/A _ _ _ _ _H 64 6-8. 9. Description of Work Class 1 Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic II Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 usl TestTemp. 165 Deg.F Remarks CRD SN# 8476 was refurbished with documentation provided under Quality Recelpt # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacementforSN#6713 underwork order#557265-01. **= ReplacementCRD Code of Construction Is ASME Section 111.1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section lil. Class 1.1986 Ed. No Ad. Reconciled to the orlalnal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xi. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA Slaned 52 ISI Coordinator Date /2 . 2004 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LlR09 to 1R110 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions IL 1927 InV66tor's Signature National Board, State, Province, and Endorsements Date _Z_ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. 2. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Date 021721304 b .9 v v Sheet I of I Unit I W.O. # 557266-01 Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) 3. Work Performed bvI Maechnnleal M2intannea Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A (Name) Mechanical Maintenance (Address) 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction Code ASME Sect liI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Comnonents Renalred or Renlaced. and Renlacement Comoonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9234 N/A 50-27 Replaced N/A CRD Assembly G.E. 8369 NIA Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 50-27 e Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A _ _ _ _H 646-7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I_I Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks CRD SN# 8369 was refurbished with documentation Provided under Quality Receint U 95580 and (Applicable Manufacturers Data Report to be Attached ) Installed as a replacement for SN# 9234 under work order # 557266-01. - = Replacement CRD Code of Construction Is ASME Section Ill. 1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section III. Class 1. 1986 Ed. No Ad. Reconciled to the original Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed
- 2Z%---7 ISI Coordinator Date L
.2 / y 2004 Owner or Owner's Designee, Title / CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owners Report during the period LI R09 to 1-R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. k 17 'Commissions IL 1927 lnprctor's Signature NatlonalBoard, State, Province, and Endorsements Date V 9 14 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. Owner Exelon Generation Comoany (EGC) LLC (Name) 200 Exelon Way. Kenneth Sauare. PA.. 19348 Address Plant LaSalle County Nuclear Station Date 02/23/04 Sheet 1 of I Unit 1 2. Name 2601 N. 211t Rd. Marseilles. II. 61341 (Address) W.O. # 557267.01 Repair Organization, P.O. No., Job No., etc. 3. Work Performed by Identification of System_ Mechanical Maintenance (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A 4. 5. I IUI .Ivntrol rKuu FIVUV (a) Appiicable Construction CodeASME Sect iI 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicabie Editon of Sectlon Xl Utilized for Repairs or Replacements-1989, No Ad, Code Cases None Identification of Comoonents Reoalred or Replaced, and Reolacement Components 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. A1032 N/A 46-27 Replaced N/A CRD Assembly G.E. 7699 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova I N/A 46-27 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A _ _ _ _ _ _H 646 7. 8. 9. Description of Work Class I Replacement. I = Per N-5 Code Data Renort on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 psi Test Temp. 165 Deg. F Remarks CRD SN# 7699 was refurbished with documentation provided under Quality Recelot # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# A1032 under work order # 557267-01. ** = Reolacement CRD Code of Construction Is ASME Section lii. 1971 Ed. S73 & W73 Ad. Reconciled to the orlainal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section Ill. Class 1.1986 Ed. No Ad. Reconciled to the orlignal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Slgned_:;- 6 Cec. ISI Coordinator Date 02 15e, 2004 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to L1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. ____ _Commi ssions IL 1927 Inspeyor's Signature National Board, State, Province, and Endorsements Date 2 - Z.> - 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. 2. Owner Exelon Generation Comoanv (EGCI LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) Date And.. Sheet I of I Unit I W.O. # 55726841 02/23104 3. Work Performed 1.. 22-2 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A W VVIVI-911110 "1011tV1111AY (Name) Mechanical Maintenance (Address) 4. 5. Identification of System (RD) Control Rod Drive (a) Applicable Construction Code ASME Sect III 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Sectlon Xl Utilized for Repalrs or Replacements-1989 No Ad, Code Cases None Identification of Comoonents Renalred or Renlaced. and Reolacement Comoonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 7886 N/A 42-59 Replaced N/A CRD Assembly G.E. A1006 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 42-59 Replaced N/A (8) CRD Capscrews Nova Ht.Trace N/A Receipt # 93916 2003 Replacement N/A _ _ _ _ _ _H 6 4 6_ 7. 8. 9. Description of Work Class 1 Replacement.
- Per N-5 Code Data Report on file at LaSalle County Station.
Tests Conducted: Hydrostatic I I_. Pneumatic II Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks CRD SN# Al 006 was refurbished with documentation orovided under Quality Recelit # 95580 and (Applicable Manufacturers Data Report to be Attached ) Installed as a replacement for SN# 7886 under work order # 557268-01. 1 = Replacement CRD Code of Construction Is ASME Section Ill. 1971 Ed. S73 & W73 Ad. Reconciled to the orialnal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section Ill. Class 1. 1986 Ed. No Ad. Reconciled to the orlalnal Code of Construction per PTE M91.007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Autho ization No. N/A Expiration Date N/A Signed Ceo 10Jig ISI Coordinator Date WE lve . 2004 Owner or Owner's Designee, Title .I CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L1R09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arlsigg from or connected with this Inspection. I f 104'/
- 1JUIL, Commissions IL 1927 Inspect& Signature National Board, State, Province, and Endorsements Date__
/2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Company (EGCI LLC (Name) 200 Exelon Way. Kenneth Sguare. PA., 19348 Address Plant LaSalle County Nuclear Station nags-n-IM-2nA
- Lale,
-a.Jus Sheet 1 of I Unit 1 2. Name 2601 N. 21st Rd. Marseilles. II. 61341 (Address) W n 4i 9C7!JA0n4
- w.V.
w
- RJ^V;'U Repair Organization, P.O. No., Job No., etc.
3. Work Performed by Ideantification nf Svstem Mechanical Maintenance (Name) Mechanical Maintenance (Address) tRpn C'nntrni Rond Driva Type Code Symbol Stamp NIA Aithorlatinn Nno NIA Exoiration Date NIA Or 4. 5. (a) Applicable Construction Code,_ASME Sect liI 19 71 Editlon No Addenda, Code Cases 1361-1. & 1361-2 (b) Appilcable Edition of Sectlon Xl Utilized for Repalrs or Replacements-1989 No Ad, Code Cases None Identification of Comoonents Reoalred or Replaced, and Replacement Comoonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 7594 N/A 42-39 Replaced N/A CRD Assembly G.E. 8408 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova NIA 42-39 Replaced N/A (8) CRD Capscrews Nova H. Trace Code A Receipt # 93916 2003 Replacement NIA _ _ _ _ _H 64 6 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Revort on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic II Normal Operating Pressure I X I Other Visual Pressure 1040 Psl Test Temp. 165 Deg. F Remarks CRD SN# 8408 was refurbished with documentation provided under Quality Recelot # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 7594 under work order # 557269-01. ** = Replacement CRD Code of Construction Is ASME Section lit. 1971 Ed. S73 & W73 Ad. Reconciled to the original per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section lii. Class 1.1986 Ed. No Ad. Reconciled to the orialnal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xi. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A Signed ISI Coordinator Date o-24/d . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 jA 4 .Z* '2L 4 ,2.. Commissions IL 1927 InspectE;FSignature National Board, State, Province, and Endorsements Date 2 Z 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner .xe.n Generation Co.nanv (EGC_ L.C Date 02123/04 (Name) 200 Exelon Wav. Kenneth Sauare. PA.. 19348 Address Plant LaSalle County Nuclear Station Sheet I of I Unit I 2. Name 2601 N. 21' Rd. Marseilles. II. 61341 (Address) W.O. # 557270-01 Repair Organization, P.O. No., Job No., etc. 3. Work Performed h-e 22.r1lon - - - - - -r my mvnnslmleac (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. 5. 6. Identification of System (RD) Control Rod Drive (a) Applicable Construction CodeASME Sect iII 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Components Repalred or Replaced, and Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Bulit Replaced, or Stamped No. IReplacement (Yes or No) CRD Assembly G.E. 6726 N/A 22-03 Replaced N/A CRD Assembly G.E. 9256 N/A Receipt # 95580 2004 Replacement NIA (8) CRD Capscrews Nova N/A 22-03 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A H646 II 7. S. 9. Description of Work Class I Replacement. a = Per N-5 Code Data Renort on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp. 165 Deg. F Remarks CRD SN# 9256 was refurbished with documentation provided under Quality Recelot # 95580 and (Applicable Manufacturer's Data Report to be Attached) Installed as a replacement for SN# 6726 under work order # 557270-01. = Reolacement CRD Code of Construction Is ASME Section 111.1971 Ed. S73 & W73 Ad. Reconciled to the orialnal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section 1i1. Class 1. 1986 Ed. No Ad. Reconciled to the original Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Rgn.e4 M ISI Cnordinatnr D ate l-Al A 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to LR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. zjk;. h Commissions IL 1927 Ins",tOor's Signature National Board, State, Province, and Endorsements Date .2 -. t - 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Comnanv (EGC) LLC (Name) 200 Exelon Way, Kenneth Square, PA., 19348 Date 02123104 Address Plant LaSalle County Nuclear Station 2. Sheet I of I Unit I Wn
- 5A7271-01 Name 2601 N. 21s' Rd. Marseilles. II. 61341 (Address)
Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A 3. Work Performed by-Mechanical Maintenance (Name) Mechanical Maintenance (Address) Expiration Date_ N/A 4. 5. A Identification of System (RD) Control Rod Drive (a) Applicable Construction Code ASME Sect iII 19 71 EditIon No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repalrs or Replacements-1989 , No Ad, Code Cases None Ientifientinn nf (onmnnnents Renalrad or Rantaced-and Ranlacrment Comrnnents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9368 N/A 18-39 Replaced N/A CRD Assembly G.E. 8503 N/A Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova NIA 18-39 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A _ _ _ _ _ _ _H 646 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Renort on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 esI Test Temp. 165 Deg. F Remarks CRD SN# 8503 was refurbished with documentation provided under Quality Receipt # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 9368 under work order # 557271-01. ** = Reolacement CRD Code of Construction Is ASME Section Ill. 1971 Ed. S73 & W73 Ad. Reconciled to the origlnal per PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Canscrew Code of Construction Is ASME Section lil. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A S l a n e d 9 4: ISICoordinator Date O 'L/*2. 9 . 2004 Owner or Owner's Designee, Title .1 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to LIRIQ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. e&& -ez '* '~ZCommissions IL 1927 Inspe s Signature National Board, State, Province, and Endorsements Date_ _ _____2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Sauare, PA., 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21'4 Rd. Marseilles. 11. 61341 (Address) Date 02/23/04 2. Sheet I of I Unit I Wn
- 557272-01 3.
Work Performed by Irnnitr~tln f v9 a Mechanical Maintenance (Name) Mechanical Maintenance Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A (Address) (RDI Control Rod Drive 4. 5. ItlE:lililltidllUII Us {Y>lBlil-(a) Applicable Construction CodeASME Sect iII 19 71 Edition No Addenda, Code Cases 1361-1. & 1361.2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None identlflcation of Components Repalred or Replaced, and Replacement Components Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Mfr. No. Bd. Identification Built Replaced, or Stamped l No. Replacement (Yes or No) nbly G.E. 7467 N/A 18-11 Replaced N/A nbly G.E. A945 N/A Receipt # 95580 2004 Replacement N/A
- crews Nova N/A 18-11 Replaced N/A screws Nova Ht. Trace Code NIA Receipt# 93916 2003 Replacement N/A H 646_
Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 psi TestTemp. 165 Deg.F Remarks CRD SN1* A945 was refurbished with documentation trovided under Oualitv Recelot # 95580 and 7. 8. 9. (Applicable Manufacturer's Data Report to be Attached) Inst11a4 as a rentaeamant fnr SNJU 7AR7.,nrwArk onrdr, 557277.-1. *^ = Reanarement R Cnode rof Construction Is ASME Section Ill. 1971 Ed. S73 & W73 Ad. Reconciled to the original ver PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section ill. Class 1. 1986 Ed. No Ad. Reconciled to the orlalnal Code of Construction oer PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xi. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A Sinned Z 6 t ISI Coordinator Date OA /5Z . 2004
- U
- Owner or Owner's Designee, Title
.1 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Ilinois and employed by The Hartford Steam Boller lnsp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIRIO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. / cZ 4./ ? Commissions IL 1927 Inspect Signature National Board, State, Province, and Endorsements Date _-___ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. Owner Exelon Generation Comoanv (EGC) LLC
- (Name) 200 Exelon Way. Kenneth Sauare. PA.. 19348 Address Plant LaSalle County Nuclear Station Date 02123104 Sheet I
of I Unit 1 2. Name 2601 N. 21" Rd. Marseilles. 1i. 61341 (Address) W.O. # 557273.01 Repair Organization, P.O. No., Job No., etc. 3. Work Performed he. IS-I-&lra - - - - - (Name) Mechanical Maintenance (Address) _ Type Code Symbol Stamp N/A Authorization No. NIA Expiration Date NIA 4. 5. 6. Identification of System (RD) Control Rod Drive (a) Applicable Construction Code._ASME Sect III 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Components Repaired or Replaced, and Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9130 N/A 10-35 Replaced NIA CRD Assembly G.E. 6824 NIA Receipt # 95580 2004 Replacement N/A (8) CRD Capscrews Nova N/A 10-35 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code NIA Receipt # 93916 2003 Replacement NIA H646 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 rsi Test Temp. 165 Deg. F Remarks CRD SN# 6824 was refurbished with documentation orovided under Quality Receipt # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Installed as a replacement for SN# 9130 under work order # 557273.01. ** = Reolacement CRD Code of Construction Is ASME Section Il1. 1971 Ed. S73 & W73 Ad. Reconciled to the original Der PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section Ill. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Reolacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Slnned
- e.
C I-RI (nnrdinatr t 0 Z1.52 f 200A _Ow o Ow n e
- Dsn,
-Titl Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind ar sing from or connected with this Inspection. Commissions IL 1927 InspeeFr's Signature National Board, State, Province, and Endorsements Date __ 2_ 9 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner Exelon Generation Companv (EGC) ILC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Date 02/25/04 2. Name 2601 N. 21' Rd. Marseilles. II. 61341 Sheet I of I Unit I W.O. # 557274-01 Repair Organization, P.O. No., Job No., etc. (Address) 3. W-Al 0-4-Amve h-Mrhanl.*,.iI. Malnt~annn. u^ l-(Name) Mechanical Maintenance (Address) Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. 5. AR Identification of System (RD) Control Rod Drive (a) Appilcable Construction Code ASME Sect iII 19 71 Editlon No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad, Code Cases None Idpntlifiatinn nf Ctomnnnenta Renalrpd nr Ranlaaed. and Renlaremrnt Cimnonants Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 7829 N/A 10-23 Replaced N/A CRD Assembly G.E. 7876 N/A Receipt # 95580 2004 Replacement N/A Piston Tube Assy G.E. 7876 N/A N/A Replaced N/A Piston Tube Assy G.E. 0501 NIA RiN/QRI M97.01688 Replacement N/A (8) CRD Capscrews Nova N/A 10-23 Replaced N/A (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement N/A 7_________ PADB~_ F H646 A C_._*4 7. 8. UescripUon o o Work brass 1 uieoiacemen - = ever N-D I.oe uaTa ueoori on Tile Ux Larane unIv ation. Tests Conducted: Hydrostatic I I Pneumatic I _I Normal Operating Pressure I X I Other Visual Pressure 1040 osl Test Temp.' 165 Deg. F Remarks CRD SN# 7876 was refurbished with documentation provided under Quality Recelit # 95580 and (Applicable Manufacturer's Data Report to be Attached ) Infntlled as a ,replnamant for NJM 782 under rwork nrelar # 5577A.241 RonIeamman CRn ConrA nf 9. -Construction Is ASME Section Il1. 1971 Ed. S73 & W73 Ad. Reconciled 1 88-396 on file at LaSalle Station. Renlacement Canscrew Code of Consl iainal per PTEs PTE 88-013 & PTE Is ASME Section ill. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction per PTE M91-007-0320-01 on file at LaSalle Station.
- rIhA 6-1-a lea hh at9.--
I "_n -o ->I -a -&lsar usnr%
- 01fi, no-Y t
h&S. -pith16-14 ClI& nens I, Ila VIuna Dlslon,.u aaV. VI,cula.0ceme1 1"U 4,rI ro U was reUlaueu wi., a new
- IULII IUUC WILIN 0111 UDU1 CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Renlacement conforms to the rules of the ASME Code, Section Xl.
(repair or replacement) Type Code Symbol Stamp NONE Certificate of Auth3ization No. N/A Expiration Date N/A Signed ISI Coordinator Date OS/", / . 2004 Owner or Owner's Desianee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 'Illinois and employed by The Hartford Steam Boller Insy. & Ins. Co. of Connecticut have Inspected the components described in this Owner's Report during the period I1 R09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. A h. 4. / -If Commissions IL 1927 Ins or's Signature National Board, State, Province, and Endorsements Date __ 3-5 _2004__
Address; r X 3Caztificate IoldAseftompeleted ea t ~iia n eif S/N of Part :~51Nai Bd. No. ~ W-1c aa: 798D228GO12 Rey 35 Dwg. Prepared by I.s jcal Edition 1974 Addenda Date tVYM 5 case No. _ mX -2_ t
- lass, 3.
REP.jVS: Wgii a
- ~e ca
. hctrsh36ce!&f~stedat 182S Dst. n.t B rief d6-btrtption of servtce tor Wbirb componen was designed
- 2.
I t s tI I c t.' Ve certify that the statements in this report are correct and this vessel part or appurtenance *s defisAd it the_ confonrs to t:e rules of construction of the ASKE Code Section 111. I The applicable Designed Specifkcstlon!adgS Report are not the responsibility of the NPT Certificate hbider for parts. An OPT Certification Noldetrfor rt is responsible for furnishing a separate Design Specification and Stress Report if the appurto ae h mat hacln the cwmponent Design Specification and Stress Report ) Date: 12103196 Signed GE-NE By C DPT Certificate Bolder 1 z SC QA 3epiresettive Certificate of Authorization Expires: 61169 Certification of Authorization No. : NPN- *tS1 certification of Design for Appurtenance Design infr-natton on file at GEComnrarnv. San Jose. Califomni Stress anal)sls report on file at GEComoanv. Son Jose. Califomia DC21A6253 ;ev 2 Design specification certified by f3N Sridher Prof. ErJ State Caif. Reg. No. tB< DC22A6254 Rev I Stress analysss report certified by Ed.vLd YoShbk Prof. Eng. State.. wff. Keg. No. A Certification of Shop Inspection I. the wnae i.;ned. holding a valid comwission by the National Board of aoiler and Pressure Inspectors andjor the S;I e or P-. wce of North Carolina and am loyed by _Degartrnentof Labor of S hver inspected ^e cart :f a pressure vessel described in this Partial Data Report on S and state *-.: to :re Dest of my knowledge and belief, the NPT Cert ficate Holder has constr6trd ths part in ac:ordance
- h :he ASME Code Section 111.
By signing :^ s ce-t:ficate. neither the Inspector nor his woployer makes any warranty, expressed or iplied, corcernino -. cart,escribed In the Partial Data Report. Furthermore. neither the Inspector nor his employer s5 I te i. -le in 3.iy manner for any personal injury or Property damages or a loss of any kind arising fron or
- tectcd
- ^ s nspection.
I -T.. /- NC 123 1. Ohio. WC 3686 PA Date Inspector' Signature lationsi Board. State. Prowine. an4 No.
- Suoppemcntal sheets in form of lists, sketches or drawinq inay be used rovided t2l) size is 8-12" X Iw, (2) information inl-2 on this Data Ncvort is Inciuded on-each sheet and (3) each sheet Is numbered and nubber o: sheets is recorded in item 3. REMARKS".
,.{ t7 1I
W sj Dw. r e by r;L Dg.' Piipared by e
- 1. CAP 166M927'p SAIS2-F316 3T b, I V/ir CO 2 hdk srrTa 1670490&PW1 S£31?- TP316 3/14ach40- wnisp'm a~ 117, WM V*knmpa 1.065-mta AL I. Pluo 159A1176Poot SA12-F304 11/4ffhk xO. 8 1200
- 4. Fkpge 91906CPOt f719E4?4)
SA 182 - F304 a3rV*kJr9 S/roo & Hed 1298353O5 5SA 19 - f304 71r oVsck x2 87W die. 6 Rin FlnO 11405 122P002 SA182 - F304 1thk x5.0O00x 1.75'D
- 7. CAo Screw 11704516P002 SA 193 - Ed 6 ".
1/12dw n t 1/Orbolt CCAe U. Plug 17SA7961PO I SA 12 -F304 0.38'VUckx 1.307 dia. 9 NOt 11485460P001 XU-19 5A479 1.3O'tc x 2.6rd1& rJ I AhOt. I I Cede ieZ Po rwa I 5 -~ Cede Nold f psOIrIOZ 6 Relied bt.ro Reld 9
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Company (EGC) LLC Date 02V25/04 (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Sheet I of I Address
- 2.
Plant LaSalle County Nuclear Station Unit I Name 2601 N. 21"t Rd. Marseilles. II. 61341 W.O. # 557275-01 (Address) Repair Organization, P.O. No., Job No., etc.
- 3.
Work Performed by Mechanical Maintenance Type Code Symbol Stamp N/A (Name) Authorization No. N/A Mechanical Maintenance Expiration Date N/A (Address)
- 4.
Identification of System (RD) Control Rod Drive
- 5.
(a) Applicable Construction Code ASME Sect iII 19 71 Edition No Addenda, Code Cases 1361-1. & 1361-2 (b) Applicable Edition of Sectlon Xl Utilized for Repalrs or Replacements-1989 No Ad, Code Cases None
- 6.
Identification of Components Repalred or Replaced, and Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) CRD Assembly G.E. 9576 NIA 02-19 Replaced N/A CRD Assembly G.E. 6220 N/A Receipt # 95580 2004 Replacement N/A I I I II (8) CRD Capscrews Nova I NIA 02.19 Replaced NIA (8) CRD Capscrews Nova Ht. Trace Code N/A Receipt # 93916 2003 Replacement NIA _ _ _ _ _ _ _H 64 6_
- 7.
Description of Work Class I Renlacement. * = Per N-5 Code Data Renort on file at LaSalle County Station.
- 8.
Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1040 osI Test Temp. 165 Deg. F
- 9.
Remarks CRD SN# 6220 was refurbished with documentation Provided under Quality Recelot # 95580 and (Applicable Manufacturer's Data Report to be Attached) Installed as a replacement for SN# 9576 under work order # 557275-01. = Replacement CRD Code of Construction Is ASME Section 111.1971 Ed. 873 & W73 Ad. Reconciled to the original ver PTEs PTE 88-013 & PTE 88-396 on file at LaSalle Station. Replacement Capscrew Code of Construction Is ASME Section lil. Class 1. 1986 Ed. No Ad. Reconciled to the orlainal Code of Construction Per PTE M91-007-0320-01 on file at LaSalle Station. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorlztor No. NIA Expiration Date N/A Signed 4 ISI Coordinator Date . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have inspected the components described In this Owner's Report during the period L1 R09 to 1R-110 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. A"/. Commissions IL 1927 InsVIttor's Signature National Board, State, Province, and Endorsements Date J J 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) Date 03116/04 Sheet 1 of I Unit I 2. 3. Work Performed 1-UA.e..nnl.e MRAnt.ansnr W.O. # 557289 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A My m v w va a itv l ls (Name) Mgechnntea MUlnfananpa (Address) 4. 5. A Identification of System (NB) Nuclear Boller (a) Applicable Construction Code ANSI B31.7 19 69 Edition NO Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad, Code Cases None Ideintificatinn of Cnmrnnents Ranareid or Rantarprd and RpilarpmAnt nmrnnnonntq Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (1)- Load Stud PSA N/A INB13-1001S Replaced N/A Assy (PSA-1) (1)- Load Stud BASIC-UTC #2651428 N/A INB13-IOOIS 2002 Replacement NIA Assy PSA CID # 6709 (8)-1.25" dia. head N/A Line 1NBI3A-4" Replaced N/A vent flange studs (8)-1.25" dia head NOVA Ht. Code LWY N/A CID 24747 Replacement N/A vent flange studs UTC # 2003318 Receipt # D99-00257 (16)-I25" dia. head N/A Line 1NB13A-4" Replaced N/A ventflange nuts (16)-I.25" dla. head NOVA Ht. Code FSD N/A CID 37042 Replacement N/A vent flange nuts UTC # 2625025 Receipt # 96897 I. uescription or Workt; rpa~ s 1 Kellacemee fnr tho RPontnr Ha2d vent IIna 1NR13A.A" . - -1 _.1.
- n. -t
.nna <qua ass mni o FU E Ie n nia -n n 8. 9. Tests Conducted: Hydrostatic I__I Pneumatic II Normal Operating Pressure l X I Other Visual Pressure 1040 nsl Test Temp.1L62 Deg. F Remarks: ^ = Per Origlnal Desian Specification J-2530. The old PSA-I mechanical snubber was also replaced with (Appilcable Manufacturer's Data Report to be Attached) a new one perWork Order #488846. Orialnal code of construction for the alaln is Sect. 1111974 Ed. No Addenda. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct of the ASME Code, Section Xl. Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Rtnnpd -F iSI Coordinator and this Replacement conforms to the rules (repair or replacement) -Expiration Date NIA Date °3 /5 . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and, the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L1 R09 to L1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arisng from or connected with this Inspection. /4 L. t Commissions IL 1927 Inspe r's Signature NationalBoard, State, Province, and Endorsements Date 5_2-*5004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. 2. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station DatM 030I3I/4 Sheet I of I Unit 1 Name 2601 N. 21" Rd. Marseliles. II. 61341 (Address) W.O. # 599450 Repair Organization, P.O. No., Job No., etc. 3. Work Performed L.. SAh-n1n (Name) Mechanical Maintenance (Address) Rvot~~~~Mn {RR tn R& lrlist Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. 5. 6. IUU;II.daUlII US.J 7 *Lr.11 ur r ..uWa,. (a) Applicable Construction Code ANSI B31.7 19 69 Edition NO Addenda, Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Comoonents Reoalred or Reolaced. and Replacement Comoonents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) Mechanical PSA N/A IRR17-10075 Replaced N/A Snubber (PSA-1/4) l Hydraulic Lisega 03615730/037 N/A 1RR17-1007S 2003 Replacement N/A Snubber (Type 301856RE2) RIN 93832 7. B. 9. Description of Work: Class I Replacement of Mechanical Snubber with a Hydraulic Snubber ver EC# 335305. Tests Conducted: Hydrostatic l.A Pneumatic I_ I Normal Operating Pressure _ I Other Visual Pressure ps1 Test Temp._ Deg. F Remarks: * = Per Orialnal Desian Specificatlon J-2530. (Applicable Manufacturer's Data Report to be Attached ) CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and of the ASME Code, Section Xl. Type Code Symbol Stamp NONE this Renlacement conforms to the rules (repair or replacement) Certificate of Authorization No. N/A Signedr t"'6 a
- L ISMCotrdInafnr Expiration Date N/A Date O3' o
/ ._ 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIRIO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. / , 1 ./ -i Commissions IL 1927 Inspecys Signature NationalBoard, State, Province, and Endorsements Date tJ 7 2004 r-,,,,1> be. w
- .j; oh O
i4 i. \\.e - -
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. 2. Owner Exelon Generation Company(EGC) LLC (Name) 200 Exelon WaV. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21' Rd. Marseilles. ii. 61341 (Address) Date Sheet I of I Unit I W.0Q N 599452 03104/04 3. Work Performed bTV MRechaneni Malnftannnr Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. NIA Expiration Date NIA (Name) Mechanical Maintenance (Address) 4. 5. Identification of System (RR) Reactor Recirculation (a) Applicable Construction Code ANSI B31.7 19 69 Edition NO Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989, No Ad, Code Cases None Identification of Comoonents Reoalred or Replaced. and Reolacement Comoonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) Mechanical PSA N/A IRR17-1008S Replaced NIA Snubber (PSA-1/4) Hydraulic Llsega 036157301041 N/A IRR17-1008S 2003 Replacement N/A Snubber (Type 301856RE2) RIN 93832 7. 8. Description of Work: Class I Renlacement of Mechanical Snubber with a Hydraulic Snubber per EC# 335305. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I I Other Visual Pressure psl Test Temp.___.Deg. F Remarks: * = Per Original Deslan Specification J-2530 (Applicable Manufacturer's Data Report to be Attached ) 9. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this_ of the ASME Code, Section Xl. Type Code Symbol Stamp NONE Replacement (repair or replacement) _conforms to the rules Certificate of Authorization No. N/A SAinnd Z 52et M SInnrrdinator Expiration Date NIA Date OgF /., 91 . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller lnsp. & Ins. Co. of Connecticut have inspected the components described In this Owner's Report during the period Li R09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. A 'it! v14.A/-. Commissions IL 1927 Inspector' Ignature National Board, State, Province, and Endorsements Date____ / 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Date nw/nctn c, v*71Jvlus Address LaSalle County Nuclear Station
- 2.
Plant Sheet I of I Unit I W.O. # 659252-01 Repair Organization, P.O. No., Job No., etc. Name 2601 N. 21' Rd. Marseilles. II. 61341 Address 3. Work Performed by-Mechanical Maintenance (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. 5. Identification of System - (MS) Main Steam (a) Applicable Construction Code Sect III 19 71 Edition W'71 Addenda, Code Cases NO (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89, No Ad, Code Cases NO
- 6.
Identifcaton of Com onents Kepalred or Keplacea, ana Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement yes or No) MSIV Stem/Stem-Rockwell N/A 1B21-F028D Replaced N/A Disk Assy. Corp MSIV Stem/Stem-Flowserve 76366-3 N/A Size 26 Figure 2003 Replacement N/A Disk Assy. Corp 1612JMMNTY Valve Receipt # 86948 7. 8. 9. Description of Work: Class I Reolacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure __I Other Visual Pressure N/A psi Test Temp. NIA Deg. F Remarks: The old Main Steam Isolation Valve (MSIV) main disk assembly removed from MSIV 1B21-F028D (Applicable Manufacturer's Data Report to be Attached ) was refurbished with a new style Stem/Stem-Disk Assembly with SN# 76366-3 under work order # 659252. This newly refurbished disk assembly will be tested during installation in the field. The piston (Ht. #2730450) and main disk (S/N 210861-33) from the old disk assemblywere reused In the refurbishment. This newly refurbished component will be returned to stores and will be maintained as a snare. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xl. (repair or replai Type Code Symbol Stamp NONE _conforms to the rules cement) N/A Certificate of Authorization No. Sqlnned C:t N/A .Expiration Date Date cZ? . 2004 ...........alo Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to LIR10 I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner foranypersonal Injury or property damage or a loss of any kind arisi from or connected with this Inspection. /W, '1.4;24 - Commissions IL 1927 Inspecto6 Signature National Board, State, Province, and Endorsements Date _3 _ 2004
S -a: FORM N-2 CERTIFICATE HO4.DERP DATA REPRT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES0 As Required by the Provisions of the SMiE Cd. Sction 111 Not to Exceed O0i Das Production -s' Pg. 1 ef 2 .<,,? Flowmeve Corporation. 1900' S. Sandeoi St.; Raleigh, NC 27603
- 2. 4isuraured ior Exelon Gelezration Co., LLC. P.O0. Box 805388 Chicago, IL 60680 3.1.scst nlba.
Exeloo Generation Co., LW. LaSafle StationMarsillesIL 61341
- 4. Type PD-422894, R/B SA-105 N/A N/A 2003
^ASUE Code, Section w Vwason t: Wit..191I N/A Wooeds c...e -J1
- a. Febdicatd In e onrdamc VAV% Cesea. S~ptic (Mi. 2 Owi)
N/A PAA;n N/A ~ / 7 ~~ Material meets ASME Secton 11, 1974 Edition. No Addendak. Stenmr-Am-Disk assembly fr ize26 firure 1612 JMMNTY valve,
- a. Nam. Wdotoss Pm.)
NJ&..A. Mml. design Per e4 em)U i.0u *a N .j /A~ei~ owerui fts At in.1 K/iA..
- c.
S. When sippocati. Cweuficab liHoldis DeaRpssaeasahdbed er fi eota "4 Pete A e eestl Pas. PoseWDod O S" d IoembSo"A. skalIOrder srb1 'rked'O d a 76366-1 N/APat.AIAasdo I4 76366-2 it-I-..--- s~76366-4 N/A ts? 76366-5 s_-_-_ (M) (a, (S) [la) 111) 112) 113) (141 (IS) t16) ¶17) 118) 1191. 1201 '21). (22. 123) 24 II ¶313 (33) (37) .PS1I. (423 1451 An 14S) S 1481 I i '49) (501 I 10 ,sign I. r "* l
- t._ _ _ __
F N/A tten
- F
- Supplementat Information hI the lotm of ista. sketches. ot di"Ings may be ued provided 11) site IsV Ira 11. 121 InWormation hI honms 2 and 3 on shis Oftf Abport hI Lncicdod on each shoet. 131 each sheet Is numbered and the number of theets Is tecorded ot Ihc top of this forrm 0"I This torm (1300401 mey be Obtained from the Orden Dept.. ASME. 22 Low Drov, SBox 2300. FoIrfield. NJ 07007.2200.
r
J
- -.,I
.-. w.: 44}r4N)c: I.-, I
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI
- 1.
Owner Exelon Generation Companv (EGC) LLC Date 03/05/04 (Name) 200 Exelon Wav. Kenneth Snuare. PA. 19348 Sheet I of I Unit I Address
- 2.
Plant LaSalle Countv Nuclear Station Name 2601 N. 21*t Rd. Marseilles. II. 61341 Address W.O. # 659253-01 Repair Organization, P.O. No., Job No., etc. 3. IAn-L, Dk..rnrl Ilahal al 2 Wwwa Ai (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Authorization No. NIA Expiration Date NIA 4. 5. identification of System (MS) Main Steam (a) Applicable Construction Code Sect iII 19 71 Edition W'71 Addenda, Code Cases NO (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89. No Ad, Code Cases NO
- 6.
Identification of Corn onents Repaired or Replaced, and Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) MSIV Stem/Stem-Rockwell NIA 1B21.F028C Replaced NIA Disk Assy. Corp MSIV Stem/Stem-Flowserve 76366-5 NIA Size 26 Figure 2003 Replacement N/A Disk Assy. Corp 1612JMMNTY Valve _ _ __ _ Receipt # 86948 8. 9. Description of Work: Class I Realacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure II Other Visual Pressure NA psi Test Temp. /A Deg.F Remarks: The old Main Steam Isolation Valve (MSM main disk assembly removed from MSIV 1B21 -F028C (Applicable Manufacturer's Data Report to be Attached ) was refurbished with a new style Stem/Stem-Disk Assembly with SN# 76366-5 under work order # 659253. This newly refurbished disk assembly will be tested during Installation In the field. The piston (Ht. # 2730458) and main disk (SIN 210861-41) from the old disk assembly were reused In the refurbishment. This newly refurbished component will be returned to stores and will be maintained as a snare. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xl. (repair or replai Type Code Symbol Stamp NONE - conforms to the rules -ement) Certificate of Authorization No. Signed 6 - = M1A r pnruatinnsI L0 lath--- -...~ul Ud N/A ISI Coordinator Date °3. Z , 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LR110 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising f om or connected with this Inspection. ZIO/' ldutZ-Commissions IL 1927 Inspecto Signature National Board, State, Province, and Endorsements Date_ 2004
' x. 8694:8 FORM N-2 CERTIFICATE HOWDERS! DATA REPfORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCESY As Required by the Provowns of thU ASME C:de. Section lt Not to Exceed OnoDay's Producton _~~~ ~ ~ ,__O_ f 2 _-,ijo by Flowserve Corporationm 1900S. Saunders St, Raleig, NC 27603
- 2. PAaJ fu Exelon Gcerion Co., LLC, P.. Box 80S388, Chicago, IL 606-0
- 3. Lti or ExlonC Generation Co., LLC, LaSalle Station, Marseilles, IL 61341 PD-422884, R/B SA-IOS N/A N/A 2003 vpr 6.f O"
b-W Wpin O" OM"f-be. he 5.ASE Cd1. Sn101ML DkhOl t. 1971 W-mter. 1971 1 NMA . Fecim I.mcd w _ Coat Spec (06v. 2 oe'Jy) N/A p..,, N/ NA - WA. -J7 7 MlaterimeetsASMESectionl,1974Edition NoAddenda. SterWStem-Disk ssenblyforsiz226 fieture 1612 JMMNTY valve, Il. momn. "kban ,L) NA WUI design Id p Pa r!
- 4r
- i. s b
N/A U) (t & .b; v...... Lai o'uU tft kI.)..JL....
- 9. WhW appacate. C DixRbf d taoNo Repeats m we.sK h
h .eon .f i. _epoa, &Wnd seI 4 Pu i Pea-' .s ea '.1 4, .I.4 111,0__ O I Numerica aOrdef 76366j-1 ,,NA, r4 76366-4 N/A g~76366..3 17) FM r j6i66-S _ z-'~ - NJA WA (61 17) (9) (10) (11 ) 1121 113) (14) (15) (16) 1171 118) (19) 520) (21) '22) 123) (243 PM0 531) cm2 .33 (34 (3S) (36w '37) r38) 139) 140) 1411 (42) 143) e wd 144) (45) A rA 146)~ (47) 148) (0') I_ (S O) __I_
- 1I I
12 5 0 5 7 5 III r . ~ ~ ~ d. i ( m b *
- 10. r) %g prim r
-r.** it:,u.;. N/A I-fl (M Supplemintal Information In the foam o ists,?. thetchs,. of dtaWu.¶ga may be mated W-oded ii) aits Is 11/% a, II. (21 Infrmation In Itrems and 3 on ti~s Dale Repo'1 Is Included! an each sheet. (31 each shoot Is numbered and the numbe' of sheetst Is ecarded at the top of Chis oarm. (71W) This form 1E000401 may be ibtalnid latom the Orde, Dept.. ASME. 22 Law Delv. Bo* 2300. Falhsld. NJ 07007 .ZI23M -S
C V M F CAi W C W P R " S -. Desgn $e wdn'c ferdi byg tE. 5 tafte.ao ~~~~~~: , ;.. 4.., S,.+.;.Mt tka>.o,2.w tdStak bants nu ' In
- o ! :
.e -pm ,t am. /iYo3S.fiQVJ/ Z- 'M ._fom to VW .ua.~to of th A
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Date_ 03/26/04 Address Plant LaSalle County Nuclear Station Sheet 1 of I Unit 1 2. Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) 3. Work Performed by_ Mechanical Maintenance W.O. # 660755 Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A (Name) Mechanical Maintenance (Address) 4. 5. A IdentIfication of System (C41) Standby Llauld Control (a) Applicable Construction CodeASME Sect. III 19 71 Edition S73 Addenda, Code Cases None (b) Applicable Edition of Sectlon Xl Utilized for Repairs or Replacements-1989 No Ad. Code Cases N-416-2 Identftifininn nf Comonnnnts Ranalsrd or Ranlaepd-and Rpniarpment Conmnnnent
- a.
-..,,,,-,-.rho.ra-.A r a w Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) Valve Bonnet to N/A 1C411-F006 Replaced N/A Body Weld Valve Bonnet to Exelon N/A N/A 1C41-F006 2004 Replacement N/A Body Weld Valve Disc N/A 1C41-F006 Replaced N/A Valve Disc Edward Valves SIN AO-13 N/A 1C41-F006 1990 Replacement NIA Inc. UTC # 2016920 Receipt # L90-0304 8. 9. Description of Work: Class 1 Renlacement * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I _I Normal Operating Pressure I X I Other Visual Pressure 1050 osl Test Temp. Ambient Deg. F Remarks: Replacement disc was acceoted Per Evaluation L90-06.0397. (Applicable Manufacturer's Data Report to be Attached) CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. Slaned KIIA =AIJlid h~lln n& vlf V-ApIlativil MI r--41 WOLO N/A Date 5 / . 2004 .a. wwvuzWouvw Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to LIRIO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind rising from or connected with this Inspection. /4 Commissions IL 1927 Inspctor's Signature National Board, State, Province, and Endorsements Date 5 2004
t 4 i-I :,,j U' ?' 1.I T'T:
- (21 Is) lei (10)
(11)
- t i e.
131. "14) s15)
- I III
'17) I i' f13l - ,) fill (201.. 121) 1221 (231 124) (25) -t
- s
^ K) 1O. LnIInf pieswi.. 84Nlmewa khfiwawim hi W k-' 's :wue en sed sie II 'sa3h 'if 6iAmh .h Is..
'I, I 1 1-1 4 .. 1. --;iv . ':ii $ Desion spiiticsuons e mfied by Design report ' cenf ed by i We cety that the statements m conform 1 to th rules of contruC NPT Certificate of Authordston A Date Name. ~'. I. 4.P. '4. f rww ... I,, I '.'.,I ? it 1'.. # I '. "..,-. 14".. I J ': I '- f-4. CERTIFICATt"OF Sb ads in this 49n"s' "'im "t tion of the ASMA Cxde. 5ecti~n 41ii-j* 4 4 I r__r w 9... 1 0~1cF f I
- 1. the undersigned, holding evalldeommlW loA issue MA nd1jCbwlLjh anderrmpiloyedby T
f3 of HI4rw n'T CTr haveinespcted theise nDema RiothosmOctteri on - v tL t.j3 beet of my knowledge end belief, the Certificate Holder has i Icated th ec pan r apunec hE Ajta t 111. Each part Noted hs ben authorized for etamping on the nee oho.; *P#"4 By signing ths certifate, neither the Inspector nor hs SmpWr mlce any warrantyo in this Data Repon. Funhermore. neither the inspector nor his employer shell be lIable any mn r arny 0Pe41 iry 8o r pm e lose of any kind arising from a ced wt his Inspection. Date /4J.Lk2 Signed Commissions A -uAS*
- -,,.Mu1,IWW, S. '
rt,uaJ,, ~e e.Xpe4 J~~ or Ix."
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Sauare. PA., 19348 Address
- 2.
Plant LaSalle County Nuclear Station Date 03117/04 Sheet I of I Unit I W.O. #96094699 Name 2601 N. 21' Rd. Marseilles. II. 61341 Address Repair Organization, P.O. No., Job No., etc. 3. 4. 5. Work Perfomied b,v Me.hsnleal Malntanen (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Identification of System (RH) Residual Heat Removal (a) Applicable Construction Code Sect iII 19 74 Edition No Addenda, Code Cases NO (b) Applicable Edition of Section Xl Utilized for Repalrs or Replacements-19 89, No Ad, Code Cases N416.2 Identification of Comnonents Renalrad or Renlaced. and Renlacement Comnonents 6. Name of Name of Mfrs. Nat'l Other Year Repaired ASME Code Component Mfr. Ser. Bd. Identification Built Replaced, or Stamped No. No. Replacement (Yes or No) (1)-1.5" dia. C.S. Half NIA 1E12-F325A/F326A Replaced N/A Coupling (1)-1.5" dia. S.S. Half Consolidated Ht. Code N/A CID 2777 1996 Replacement NIA Coupling Power Supply 207YNA UTC 2062444 Receipt # L96-00988 l (1)-1.5" x 0.75" dia. NIA 1E12-F325A/F326A Replaced NIA C.S. Reducing Insert. (1)-1.5" x 0.75" dia. Chicago Tube Ht. Code N/A CID 2675 1981 Replacement N/A S.S. Reducing Insert and Iron DHY UTC 2016688 ICAMCO P.O. 253664 7. 8. 9. Description of Work: Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I _I Normal Operating Pressure I X I Other Visual Pressure 1056 / 1040 Psl Test Temp. 72/165 Deg. F (Bench /Field Test) Remarks: Replaced existing 0.75" dia. carbon steel double block valves with two (2) single 0.75" dia. stainless (Applicable Manufacturer's Data Report to be Attached ) steel globe valves In order to eliminate the dissimilar metal Interface between the existing carbon steel half couolina and the stainless steel process Dipe. The existing carbon steel 1.5" dia. half couolina and 1.5" x 0.75" dia. reducing Insert was replaced with stainless steel material. Replacement Is per enaineerina change EC # 49964. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xi. (repair or replac Type Code Symbol Stamp NONE Certificate of Autho zation No. NA Expiration Date Signed to. C ISI Coordinator Date A3 ement)
- conforms to the rules N/A Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller lnso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty,expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arlg from or connected with tys Inspection. 2 41 Commissions IL 1927 Insnodor's Signature National Board, State, Province, and Endorsements Date __ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI
- 1.
Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 Address Date 03/15104 Sheet I of I Unit 1 WnO. *#60Q4702 Repair Organization, P.O. No., Job No., etc. 3. tAP--G DA ~ r e SfiJ-L-anl-a Ma wor1d renorme11u 1i Mrnncl nleac (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. 5. Identification of System (RH) Residual Heat Removal (a) Applicable Construction Code Sect Ii 19 74 Edition No Addenda, Code Cases NO (b) Appilcable Edition of Section XI Utilized for Repairs or Replacements-19 89. No Ad, Code Cases N416-2 IEdn-fifitl-n of fl m .n.n.#a Pnntranl n^r 0-an ti -nd D-ane-a -nt tf-mn-nfntc A; Name of Name of Mfrs. Nat'l Other Year Repaired ASME Code Component Mfr. Ser. Bd. Identification Built Replaced, or Stamped No. No. Replacement (Yes or No) (1)-1.5" dia. C.S. Half NIA 1E12-F325B/F326B Replaced N/A Coupling (1)-1.5" dia. S.S. Half Consolidated Ht. Code N/A CID 2777 1996 Replacement N/A Coupling Power Supply 207YNA UTC 2062443 Receipt # L96-00988 (1)-1.5" x 0.75" dia. N/A 1E12-F325B/F326B Replaced N/A C.S. Reducing Insert (1)-1.5" x 0.75" dia. Chicago Tube Ht. Code N/A CID 2675 1981 Replacement N/A S.S. Reducing Insert and Iron DHY UTC 2016688 ICAMCO P.O. 253664 7. 8. Description of Work: Class 1 Replacement. ^ = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 103811040 osl Test Temp. 691165 Deg. F (Bench/Fleld Test) Remarks: Replaced existina 0.75" dia. carbon steel double block valves with two (2) single 0.75" dia. stainless 9. (Applicable Manufacturer's Data Report to be Attached ) steel alobe valves In order to ellminate the dissimilar metal Interface between the existina carbon steel half coupilna and the stainless steel orocess plie. The existinq carbon steel 1.5" dla. half couplina and 1.5" x 0.75" dia. reducing Insert was replaced with stainless steel material. Replacement Is per engineering chanae EC # 49965. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this I of the ASME Code, Section Xl. (rel Type Code Symbol Stamp NONE Certificate of Auth izatlon No. N/A Expiration Date _ Signed 6 ISICoordinator Date_ Owner or Owner's Designee, Title 2lnl -fm fnG - - -*rnc to the rules pair or replacement) NIA 2004 I1 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LiRO9 to LiRiO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with t is Inspection. s s Commissions IL 1927 Inspec7 s Signature National Board, State, Province, and Endorsements Date /2 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. 1i. 61341 (Address) nate 0318/ 04o Sheet 1 of I Unit I W.O. # 980107485-01 2. Repair Organization, P.O. No., Job No., etc. 3. Work Performed h.. IUMvh1nrfi WY n,..IanIuar ,,a,,enac (Name) Mechanical Maintenance Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A 4. 5. 6. (Address) Identification of System (RR) Reactor Recirculation (a) Appiicable Construction Code ANSI B31.7 19 69 Edition NO Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989.No Ad, Code Cases None Identification of Components Repaired or Replaced, and Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) Mechanical PSA 16294 N/A IRR17-1001S Replaced N/A Snubber (PSA-1/4) Mechanical PSA 37751 N/A IRR17-1001S 1986 Replacement N/A Snubber (PSA-114) QRI 86-1044 I M96-03232 8. 9. Description of Work: Class 1 Reolacement of Mechanical Snubber 1RR17-IOOIS. Tests Conducted: Hydrostatic IIJ Pneumatic I _I Normal Operating Pressure II Other Visual Pressure ps1 Test Temp.__ Deg. F Remarks: ^ = Per Original Design Specification J-2530. Note that this mechanical snubber was replaced with a (Applicable Manufacturer's Data Report to be Attached ) new LUse-za hydraulic snubber In Li R10 {Ref. W. 0. # 470338). CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this_ of the ASME Code, Section Xi. Type Code Symbol Stamp NONE -nfnn -o -h-relax -I (repair or replacement) Certificate of Authorization No. N/A I Siane5natr< Expiration Date N/A Date ° /-- 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and* employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR08 to LR-10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4-Ai.u 001A..4 4 i~...Commissions IL 1927 pector's Signature National Board, State, Province, and Endorsements Date _A__ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way: Kenneth Square. PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Date-03112/04 Name 2601 N. 21't Rd. Marseilles, II. 61341 Address Sheet 1 of 1 Unit I W.O. #99047389 Repair Organization, P.O. No., Job No., etc. 3. Work Performed by_ Mechanical Maintenance (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A 4. 5. A6 Identification of System (RR) Reactor Recirculation (a) Applicable Construction Code Sect III 19 74 Edition No Addenda, Code Cases NO (b) Applicable Edition of Section XI Utilized for Repairs or Replacements-19 89, No Ad, Code Cases N416-2 Identification of Cnmnonants Renalred or Renlaced. and Renlacement Comronents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (2)-2" dia. S.S. Kerotest NIA 1B33-FO51AJ52A Replaced N/A Globe Valves (1)-1.5" dia. S.S. Yarway Corp. C3290 NIA 1B33-FO51A 1995 Replacement NIA Globe Valve Receipt # 65351 (1)-1.5" dia. S.S. Yarway Corp. C3136 N/A 1B33-F052A 1995 Replacement NIA Globe Valve Receipt # 65351 2" dia. S.S. Pipe 1N/A B33-F051AIF52A Replaced N/A 1.5" dia. S.S. Pipe Consolidated Ht. # NIA 1B33-F051AIF52A 1995 Replacement N/A Power Supply A4556H Recelpt # L99-02113 7. 8. 9. Description of Work: Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I X I Pneumatic lI Normal Operating Pressure II Other Visual Pressure 1079 osI Test Temp. 75_Deg. F Remarks: Replaced existing leaking by 2" dia. Kerotest stainless steel lobe valves with new 1.5" dia. Yarwav (Applicable Manufacturer's Data Report to be Attached ) stainless steel globe valves. This replacement Is per enaineerina change EC # 51221 (DCP 9900149) and EC # 334780. For field Installation of the newly fabricated pirlng sub-assembly refer to W.O. 470338. Z CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and thisF of the ASME Code, Section Xl. (re; Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date Aind t I Coordinator f;ate Reolacement conforms pair or replacement) to the rules N/A e g2 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Li R09 to 1-RI10O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty,expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind sing from or connected with this Inspection. Commissions IL 1927 Inspfor's Signature National Board, State, Province, and Endorsements Date J 3-72-2004
Dec-27-2001 03:02pm Fr-COIm-ED 00p
- W1%vt
+6306633955 U j1~) T-554 P.036 INCA4A*9n UL AIV F-617 VA Im# &.. V V V
- )-
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES" As Required by the Provions of the ASME Code, Section III, Division I1 pg. I of I
- 1. Manufacurad enc
- 2. Manufacwured for
- 3. Locadon of install Yarway Corporation, A Subsidiary of Keystone International Inc.
480 Norristown Rd., Blue Bell, PA 19422 d certified by I* n Wtn r*i o N Cnfiate Holderi B & W Nuclear Technologies Inc., Lynchburg, VA 24506 1A1 and address of Purcnn Ot *O ne) Stock ation (naine and address) AS
- 4. ModelNo..SeriasNo..otType 5617B Drawng 111102 Rev.
_I__ ---
- 5. ASME Coda, Suction Ill. Diision 1:
1986 None 1 - 4ltwo Iaddenda data) Idus MCade Cas no.) S. Pump or vtimv Val ve Nominal Weint a1 11/2 Ouet saze SA182 SA564 ln-.l n.)
- 7. Marizail; Body 6r, F316 Bormet Gr_ 630 DIak AMSS385E Bot,,g NA (a)
Cen. Hodders SerW No. C3289 C3 Z9 0>wrt 7ra r," (;3EJ1 C32-z9 -~ ~ ~ ~ ~.. I
- F4 q-G-9
~- (bi Natl Board No. I (c) Body N-o. BT BT BY 0T_ (dl Bonnet SCana No. 7376 7376 7376 (.1 Disk Serwl No. NI NI NI NI Suppwnelninfdrnii nifnno1A1e. skledwordruwfngsmsybusdpradd I tluzis 81 x {t, I2i doyaninkitn 1 thrrujh4 an ti Daa "prt inhdued on eah *etS heh irumibed and the nunrur f ss Wm otd Isp of ah fonn. 1121s5) This totm 1(000371 way be obtained frm Via Ordr DcMt, ASMEW 22 Low 0dve. fox 2300. Farfield, NJ 07007-2300. I O I~~~~~~ 'PG.A i _r W
Dec-2T-2001 03:02pi From-COIA ED +6306633855 T-554 P-037 F-617 FORM NPIV- (back) \\<J V Remaft Valves are bonnetless design. Backseat bushing listed in lieu of bonnet. S. Design conditifon pi °F or valve pressure class 1700 4praesaf Ipe
- 10. Coldworkingpressure 4080 pal at 1000F
- 1.
Hydrostitic es 6125 psi. Disk differential tt prure 4500 CERTIJCA1MJ OF DESIGN DeanSpecificationcertlfiedby raeoaie J. Paptzun P-.sf PA . Rgm.no. PE-034809-l DflnRpr cetfe Murray W. -Randall P.stte_ MA_ I Re.no 273g5 CEITMFICATE Of SHlOP COMPLUANCE We certiy that the statemems muds ln this report ar cet nd that this pump or vahve conforms to d rue for contnncon of the ASIWE Code, Section III, Division 1. NCertificate ot Autrlon NtlnNo N244g _ Expires 11/14/95 Dawe 2WISENarme Ya rway Co?'oorati On '~,~ -! IN Cardficsat Holder S~one ~ L$~' Ia'u'horlzed _urtA ie I I CERInFICATM OF SHOP INSPECniO
- 1. the undersigned, holding a valid commission Issued by the National Board of Boaer and Presure Vessel Inspects and theStateorProvlncoof Pennsylvania andenployedby Arkwrioht Mutual Ins. Co of Norwood ML*
ha_ h rve Inspected the pump, or valve, described In this Data Report an MA 18 , 19 2iE_ and state that to te beat of my knoldga and belief. the Cartificate Holde has constnrcted this pump, or valve. In accordance with the ASME Code. Section 111. Division 1.
- Factory Mutual Engineering Association By signing ti cerfficte.
neither the Inspect nor hi emploe makes an warranty, expressed or imdlied, concerning the component described In this Data Report. Furthermole. neither the inspac or nor his employer Shall be Sable in any manner for any personal Injuiy or propey damage or a loss of any kInd arlsin from or conncted with this Inspection. fln S-18-95 Qndf W, fC7. O w.r.. W .r-. C nB amm N 791RS NT _S PA Z o4 -~ -'C--- Wuthorizad lrtw p IjatI. Bd. lindI. endavmcnfl tat seor prv. ond no.1 II) For mrnua fy operated valves only. . 11Z IVII ow (;Y
- p.
I'
Dec-27-2001 02:49pu FroU-= ED SHOP ORDER 30992 +6306633855 -9; ' 65 25 T-553 P.007 F-616 REGISTER 47000 FORM NPV-1 CERTIFIL.. #E HOLDERS' DATA NiPORT FOR NUCLeAR PUMPS OR VALVES, As Required by the Provislons of the ASME Code, Section fi1, Division 1 Pg..- L of .l Yarway Corooration, A Subsidiary of Keystone International Inc.
- 1. ManufacturedandecrtHiedby 480 -orristown Rd.. Blue Bell. PA 19422 ene.nand amdres f tN Ccrtificate Hode')
- 2. Manufacturedfor B & W Nuclear Services, SPIS, Lynchburg, VA 24506
- Wnm mmn atdf" of Purcr or Ownev
- 3. Locaton of installatlon Stock a
Inm. and addreasi
- 4. Moacet No., Series No., or Type 5617B..
Drawing 111102 Rv. None CR__--__ S. ASME Codoe. Sution ill, Division 7: 1986 None 1 tfodan) (addands dmwI Wzsl lCoda Casa no.)
- 6. Pump or valve Valve Nominal Wnket t" a
Outet kozu SA182 SA564 lln.l On.l
- 7. Mataral:
Body Gr. F316 f sonnet ri 3. mk AMS538S5E Wng NZA 11 cv Hoklds Serial No. . C3136 -, -7.I C3137 C3138 lb) Nat'l Board No. I I lc) Body Serial No. BT BT .1 .I. q-(d) (a) Bonnet Dsk Serial Serial No. No. 7376 Hi 7376 . NI 7376 NI ( I.
- iqr, -!- = OP%
MV=
- &Wpemowra Informaton In form of ts, *Jctdies. or dwknns ny b used provided III asi Is 8% X xI t 121 l nfmution In ftm 1 throuo 4 on Tsa Dt Report Is hdud oea asheet. 131 eachsees hborwd nd th. number of she
- s recorded e atop of tlis form.
(12r86) This ormm IE0037) may be obained from the order Dv., ASME, 22 Law Drive. Box 2300. FafrMleld. NJ 07007-2300. 1BW... EPP.,
Dsc-27-2001 02:50pm From-COWL ED t6306633855 T-553 P.008 F-61 6 FORM NPV-1 (back) G560 5I B. Remarks Valves are bonnetless design. Backseat Bushing listed in lieu of bonnet.
- 9. Design conditions psi F or valve pressure class 1700 (1) lptew~rel Itnmp
}arux,
- 10. Cold working pressure 4080 ps at 100°F Ii. Hydroic test 6125 psi.
Disk differential ten presmur 4500 pel CERTIFICATION OF~ VMSGu Design Specification cetifie by -G -og I-Paptztn n PsE. Stuft PA.. .Rag. no....fE-t0348Ml9.. Design Raport certified by Mu P. mneinll P.ELState - MA . Se".no..27.395 '__J CERIFICATE OF SHOP COMPLIANCE We cerrify thatthe tatments made in thi report e coet and that this punp or valve conforms to the nles for constnton of the ASME Code, Section ill, Divison 1. N Certificate ot Authoribation No N2449 Expires L5141 _5 n.# M -~Jt ~ A a. Yarway Corvoraiion; ". VW. 1 (MM96= M -, -1! I!' lzvd news IN C" M Mca Hald r) CERTIFICATE OF SHOP ISPEC~lON 1, the undersigned, holding a valid Commisslon Isaved by the National Board of Bolier and Prszure Vessel kspemtors and theStaxeotProvincuof Pennsylvania andemployedboy Arnwri !ht drbital nt -Co. a Norwood. MA* have lnspecte2 the pump. orvalve. desibed n this Da Report on ZQ j%/0 . 19 43, and ste that to the best of my knowledge and belief, the Cerifkate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section li. Diksion 1.
- Factory Mutual Engineering Association By signing this certficate, neither the Inspector nor his employer makes any watanty, expressed or Implied. concerning the compontent described In this Data Report. Furthermore, neither the Inspector nor his employer shall be gable In ary manner far any personal Injury or property damage or apsaqf any kind ariuing frn or connected with this inspection.
Date ?3SI ! 2 24A4 !WCmmicsion* -.A/i 01z&;x /0 W~ftod h"VccN M~al. Be. MCI. en1smm stl or Prov. wW noa.] [ N t. l d u iN W Pe m i r i S a s o v n. a d n.
- 1.
wo I thg
- 11) For mranuay operated valves only.
r:.. 7
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Companv (EGC1 LLC Date 03122/04 (Name) 200 Exelon Wav. Kenneth Sauare. PA.. 19348 Address LaSalle County Nuclear Station
- 2.
Plant Sheet 1 of I Unit I W.O. #99156492 Name 2601 N. 21t Rd. Marseilles. II. 61341 Address Repair Organization, P.O. No., Job No., etc. 3. WU-ls 0-rfn-Ae h-M~rhankr~b lUa ..n.a -1U[ (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Authorization No. NIA Expiration Date N/A 4. 5. 6 Identification of System IB211 Feedwater (a) I Appiicable Construction Code SectLiii 19 71 Editlon W72 Addenda, Code Cases N62-7. N-275 (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements-19 89. No Ad. Code Cases N-416-2 Idenrifinatinn of Cnmnnnents Renalred or Ranlaced-and Rnlacaement Comnonants Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (1) 24" Tilting Anchor NIA 1B21-FO10A Replaced N/A Disc Check Valve Darling (1) 24" Swing Flowserve AU577 N/A 1B21-FO1OA 2003 Replacement N/A Check Valve Corp. Receipt # 94256 1 (1) 24" O.D. x Consolidated Ht. # T3955, NIA Receipt # 85972 2003 Replacement N/A 12"L Pipe Power S/N RP-2035 Extension Supply 7. 8. 9. Description of Work Class I Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic Il Normal Operating Pressure I X I Other Visual Pressure 103211045 osi Test Temp. Ambient Deg. F Remarks Reolaced tiltina disc Inboard feedwater check valve with a swina tvve check valve per Enalneerina (Applicable Manufacturer's Data Report to be Attached) Change EC# 51394 due to chronic leak rate failure.
- New valve Is Class 1 ASME Section III 1989 No Addenda reconciled to the orialnal construction code. APOllcable Construction Code for piping Is ASME Sect. III 1974 Ed.
No Addenda. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement of the ASME Code, Section Xl. (repair or replai Type Code Symbol Stamp NONE conforms to the rules cement) Certificate of Authorization No. Signed C 444 ' N/A _Expiration Date N/A ISI Coordinator Date a 4/*6 . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insy. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LJR09 to I-R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Ci Commissions IL 1927 Inscr tor's Signature National Board, State, Province, and Endorsements Date __ _ 2004
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES* As Required by the Provisions of the ASME Code. Section III, Div. I Pg. Iof 2
- 1.
Manufactured and certified by Floivserve Corporation. 1900 S. Saunders Street. RaleiEh. NC 27603 (Namre and Adress of N Certficate Holder)
- 2.
Manufactured for Business Services Co.. P.O. Boxs 805388, Chicaoo, IL 60680 (Narne and Address i ur chaser)
- 3.
Location of Installation Exelon Generation Co., LaSaile Nuclear Station. 2601 N. 21st Road. Marseilles. IL 61341 (Nane and Address)
- 4.
Model No.. Series No.. or Type 1500# Swing Check Drawing W0125773* Rev H CRN
- 5.
ASME Code. Section IlIl. Divisi
- 6.
Pump or Valve
- 7.
Material: Body
- SA216, on 1:
1989 No I N/A (efiaon) (addenda date) (class) (Code Case no.) Valve Nominal Inlet Size 24" Outlet Size 24" (inc) rulh) WCB Bonnet SA105 Disk SA105 Bolting SA193, Gr. B7 (a) Cert. Holder's Serial No. (b) Nat'l Board No. (c) Body Serial No. (d) Bonnet Serial No. L3226-2 (e) Disk Serial No. L3226-4 AU577 NIA E7807-1 i
- Supplemental Information in form of lists. sketches ordrawings maybe used provided (1) size Is -112'x 11', (2) information In items I through 4 on this Data Report is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
7
9425:6 FORM NPV-1 (Back-Pg. 2 of 2) Certificate Holder's Serial No. AU577
- 8.
Design conditions 2600 (pressure) psi 575 (tenrerature) oF or valve pressure class 1500
- 9.
Cold working pressure 3705 psi at 100OF
- 10.
Hydrostatic test 5575 psi. Disk Differential test pressure 4076 psi.
- 11.
Remarks: Nuclear swving check valve. Stud material heat code Q318; Nut material SA194, Gr. 7, heat code 12750; Gasket Retainer material SA516, Gr. 70, heat T479415B-1; Hingle Pin Cover material SA105. heat 77296-1.4: Drain Connection material SA105, heat 77297-1; Drain Pipe material SA106, Gr. B, heat 708474-23; Drain Cap material SAI 05, heat 2854ANF-1.
- Pipe extension as shown on drawing vras not welded to this valve.
S. 0.23028 CERTIFICATION OF DESIGN Design ipedfication certified by James T. Conner P.E. State MID Reg. no. 23476 Design Report certified by R6nald S. Farrell P.E. State NC Reg. no. 028656 l ~.,
- -'CERTIFICATE OF COMPLIANCE
.i ( We certify that the statements made I cogforms to the rules of construction of Components. Section 111. Div. 1.. N Certificate of Authorization No. _ fI/ dv_.._ In -this report are correct and that this pump, or valve;d-the ASME Code for Nuclear Power. Plant N-1562 Expires N4 v. 26, 2003 Date I I/ IJcJ J 5 Name T lowserve Corporation Signed. (N Certilkate Holder) (Authorzed Representative) CERTIFICATE OF INSPECTION
- 1. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
-North.Ca rolina Lan'd emptoyed~by_- ---_BC-_-*- - -- *-of -- Harforcl-Connecticut have Inspected the pump, or valve, described in this Data Report on / I 3 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with ASME Code, Section 111. Div. 1. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the component described In this Data Report. Furthermore, neither the Inspector nor his employer shafl be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Date /1 I I / I L '7 / 14~1-1,Ai, Commissions AMY/ Sinnerd / (ks-cir (Nan Sd Sale Pray, nd o. / ~ Irtns-Cdot) (Nall Etd, State. Prov. and No.)
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner Exelon Generation Comnanv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Date 03M02104 Sheet I of I Unit I 2. Name 2601 N. 21' Rd. Marseilles. II. 61341 (Address) W.O. # 448209401 Repair Organization, P.O. No., Job No., etc. 3. Work Performed by Mechanical Maintenance (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp NIA Authorization No. NIA Expiration Date NIA 4. 5. Identification of System (MS) Main Steam (a) Applicable Construction CodeASME Sect. III 1974 Edition No Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989, No Ad. Code Cases None Identification of Comoonents Reoalred or Reolaced. and Reolacement Components 7. B. Description of Work: Class 2 Repair I = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I I Other PT Pressure N sA osi Test Temp. NIA Deg. F Remarks: Removed defective weld to base metal. Llauld penetrant testing was oerformed on the area after defect 9. removal orlor to weldina and on the final weld. Weld defect was found durina LI P03. (Applicable Manufacturer's Data Report to be Attached ) CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Repair of the ASME Code, Section Xl. (repair or repl Type Code Symbol Stamp NONE - -conforms to the rules lacement) N/A Certificate of Authorization No. __ Ala ne e < i NIA .Expiration Date IMI Cnnrdinatnr Date tO;9/ '/ . 2004 r or O e D e - Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have inspected the components described in this Owner's Report during the period Li R09 to L1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty,expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. i / 4 27 Commissions IL 1927 Insnlor's Signature NationalBoard, State, Province, and Endorsements Date __ 3_ /__ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. Owner Exelon Generation Company (EGC) LLC Date 09/15/03 (Name) 200 Exelon Way. Kenneth Sauare. PA.. 19348 Address Plant LaSalle County Nuclear Station Sheet I of I Unit I 2. Name 2601 N. 21t Rd. Marseilles. II. 61341 (Address) Wfn i Ar'RI I rn4RRIl I---- I - - - - - - Repair Organization, P.O. No., Job No., etc. 3. Wnrle P1-nrDH Mkrhanlen WWv[A ruI... r*d ,,,a,,a a, ,sc,,a,,lc (Name) Mechanical Maintenance Type Code Symbol Stamp N!A Authorization No. NIA Expiration Date N/A 4. 5. A (Address) Identification of System (RI) Reactor Core Isolation Coolant (a) Applicable Construction CodeASME Sect. III 1974 Edition No Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repailrs or Replacements-1989, No Ad. Code Cases None Identificratinn nf Crmnnnents Renalred nr Ren and Raninacmanf (`mnrnent.n Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (2)- 6 "- Std.-V-N/A 1E51-D001 and Replaced N/A R (LI) Rupture I E51D 0002 Disc (2)- 6 "- Std.-V-Continental 8018239A N/A Receipt # 90296 2003 Replacement N/A R (LI) Rupture Disc Corp. Disc I 7. 8. Description of Work: Class 2 Reolacement * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I NormalOperatingPressurel X I Other Visual Pressure 10 eSi Test Temp. Ambient Deg. F Remarks: Reolaced rupture discs every five years with new. Replacement per Design Specification J-2530 and T-3763. Code Reconciliation per Eval. L-1996-76-3. on file at LaSalle County Nuclear Station. 9. (Applicable Manufacturer's Data Report to be Attached ) CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI. (repair or replacement) Type Code Symbol Stamp NONE Certificate ofAuthorization No. N/A Expiration Date N/A Sinned eS ISI Coordinator Date -//6 . 2003 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Li R09 to 1-R110 I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Al Commissions IL 1927 spector's Signature National Board, State, Province, and Endorsements Date_ __-_6__ 2003
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. 2. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 215" Rd. Marseilles. II. 61341 (Address) Dfat a 9 v Sheet I of I Unit I W0
- 455046 03i/n10/
3. 4. 5. Work Performed b,v MA&hnnleal Maln4inan.- Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A (Name) Mechanical Maintenance (Address) Identification of System (RI) Reactor Core Isolation Coollna (a) Applicable Construction Code~_ASME Sect. III 19 71 Edition S73 Addenda, Code Cases None (b) Applicable Edition of Sectlon Xl Utilized for Repairs or Replacements-989.No Ad. Cde Cases N-416-2 Identification of Comnonents Renaired or Renlaced. and Renlacement Comnonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (1) 4"- Globe Anchor Darling NIA 1E51-F045 Replaced NIA Valve (1) 4"- Globe Flowserve AV909 NIA 1E51-F045 2003 Replacement NIA Valve Corp. I___ I___I (1) 4" dia. - Pipe Capitol Pipe & Ht. # 404625 NIA Receipt # 96441 1986 Replacement NIA Steel 7. 8. Description of Work: Class 2 Reolacement * = Per N-5 Code Data Reoort on file at LaSalle County Station. Tests Conducted: Hydrostatic IIJ Pneumatic IlI Normal Operating Pressure I X I Other Visual Pressure 915 osl Test Temp. Amblent Deg. F Remarks: Replaced valve and puD Piece with new due to valve leakina by. Replacement per Deslgn Specification. (Applicable Manufacturer's Data Report to be Attached ) J-2938-0l1 Amendment 3. Renlacement valve ner Parts Eval. #00020753. 9. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA qInned e 4 I ISI Cnordinator Date / . 2004 e rules Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIRIO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Gigf* Commissions IL 1927 Inspector'sgnature National Board, State, Province, and Endorsements Date _ 2004
95 5.0 5 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES* As Required by the Provisions of the ASME Code, Section Ill, Div. I Pg.1 of 2
- 1.
Manufactured and certified by Flowserve Corporation. 1900 S. Saunders Street, Raleigh, NC 27603 (Name and Address of N Ceificate Holder)
- 2.
Manufactured for EXELON GENERATION LLC PO BOX 805388, CHICAGO, IL 60680-5388 (Name and Address of Purchaser)
- 3.
Locationofinstallation LASALLESTATION-2601N.215TRD., MARSEILLES, IL 61341-9757 (Name and Address)
- 4.
Model No., Series No., orType 900 GLOBE VALVE Drawing W9424393 Rev F 'CRN N/A
- 5.
ASME Code, Section Ill, Divisi
- 6.
Pump or Valve
- 7.
Material: Body SA21t (a) Cert. Holder's Serial No. on 1: 1971 's 1973 2 N/A (edition) (addenda dale) (yass) (Code Case no.) Valve Nominal Inlet Size 4" Outlet Size 4', (nch) (inch) , WCB Bonnet SA105 Disk SA105 Bolting N/A (b)
- Nat'l Board No.
0"-AV909: N/A -(c) Body Serial No. 03234-TI179-* I . 1. (d) Bonnet Serial No. . 20777-2-3 (e) .Disk Serial No. 20777-2-4 _a
- Supplemental information in form of lists, sketches or drawings may be used provided (1) size is 8-112 x 11, (2) information in items I through 4 on this Data Report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
3Z
9 5 5V05 A-- FORM NPV-1 (Back-Pg. 2 of 2) Certificate Holder's Serial No. AV9o
- 8.
Design conditions 1250 psi 575 OF or valve pressure class 900 (pressxe) (temperature)
- 9.
Cold working pressure 2220 psi at 100 0F
- 10.
Hydrostatic test 3350 psi. Disk Differential test pressure 1375 psi.
- 11.
Remarks: GASKETRETAINER-SA106, Gr.B-HEAT#86724-1 SO# 25785 CERTIFICATION OF DESIGN Design specification certified by GERALD L. ZWARICH P.E. State IL Reg. no. 62-41234 Design Report certified by P.E. State Reg. no. CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump, or valve, to the rules of construction conforms of the ASME Code for Nuclear Power Plant Components. Section III, Div. 1., N Certificate of Authorization No. N-1562 Expires Nov. 26, 2006 Date { toiName Flowserve Corporation Signed_ (N Certificate Holder) (Authorized Representative) CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North GaroUca and employed by HSB CT of Hartford Connecticut have Inspected the pump, or valve, described in this Data Report on /2.
- !I2 I 0 ;
, and state that, to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with ASME Code, Section 1II. Div. 1. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. Date IZ I t I_ Signed 4ZI. fl7. Commissions issions (Inspector) (Nan 8d.. State. Prov. and No.) LY
4, FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. 2. Owner Exelon Generation Companv IEGC) LIC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Date 0310210 - Sheet I of 1 Unit I Name 2601 N. 21" Rd. Marseilles. II. 61341 W.O. # 465398 (Address) 3. Work Performed by_ Mechanical Maintenance Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. NIA Expiration Date NIA (Name) Mechanical Maintenance 4. 5. (Address) Identification of System (RH) Residual Heat Removal (a) Applicable Construction Code ASME Sect. III 19 68 Edition June'70 Addenda, Code Cases 1332-5 (b) Applicable Edition of SectIon XI Utilized for Repairs or Replacements-1989, No Ad. Code Cases N-41 6-1 Idpntifinatinn of Comnennnts Ranaltrd or Rplacend, and Rplacenment Comnnnents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) RHR Heat Struthers N/A 1E12-B001A Repaired N/A Exchanger U-Well Corp. tubes (4) Tube plugs Ecker-Heat # 233868 N/A Receipt # 92748 2002 Repaired NIA E rh ard t 7. 8. 8. 9. Description of Work: Class 2 Repalr. Reoaired "IA" RHR Heat Exchanaer bv oluaaino U-tubes. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I I Other Visual Pressure p sl Test Temp._Deg. F Remarks: Pluaged two (2) U-tubes numbers 26-15. and 26-19. Dye Penetrant test performed prior to welding, on (Applicable Manufacturer's Data Report to be Attached ) the root welds and on the final welds. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Repalr conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of A orizatlon No. Sinned N/A Expiratlon Date NIA ISI Coordinator Date o4 Z /°/ . _2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to L1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 44 Commissions IL 1927 Inspept s Signature National Board, State, Province, and Endorsements Date 2 -.// 2004 -r k
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI
- 1.
Owner Exelon Generation Company (EGC1 LLC Date 03/08104 (Name) 200 Fxalon Way. Kenneth Sauare. PA.. 19348 _ _ _ _ A _. _.. _., w. _ _ _ _ _ _. _ w. = _ 5. _ _. _l Address
- 2.
Plant LaSalle County Nuclear Station Sheet 1 of 1 Unit 1 W.O. #465766 Repair Organization, P.O. No., Job No., etc. Name 2601 N. 21t Rd. Marseilles. II. 61341 Address 3. Wrl-t D-r-ntrn.4 ha. Mlkh:nle
- uI-I Ir uI
- 'J*!UCU Ia,,,,n (Name)
Mechanical Maintenance Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date NIA 4. 5. (Address) Identification of System (RH) Residual Heat Removal (a) Applicable Construction Code Sect lii 19 74 Edition SJ75 Addenda, Code Cases NO (b) Applicable Edition of Section Xl Utilzed for Repairs or Replacements-19 89. No Ad, Code Cases NO 7. 8. 9. Description of Work: Class 2 Repair Tests Conducted: Hydrostatic 1_ IJ Pneumatic I I Normal Operating Pressure I I Other LLRT Pressure NIA psi Test Temp. Ambient Deg. F Remarks: Installed a testable flanae detail to the discharge flanae of the existing valve per IT-7000 drawings In (Applicable Manufacturer's Data Report to be Attached ) order to Improve the method of ISTIISI testing. LLRT was performed and completed satisfactorily after reinstallation of the modified valve. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this of the ASME Code, Section XI. (rep Type Code Symbol Stamp NONE Reoalr conforms to the rules iair or replacement) Certificate of Authorization No. Signed e-4f S UIA Fertl §.et NIA IC"a ISI Coordinator Date es/e9 . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to LuR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind armng from or connected with this Inspection. iJ>PX 2 7 Commissions IL 1927 Inspef37r's Signature National Board, State, Province, and Endorsements Date 3 / 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Comeanv (EGC) LLC (Name). 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21'4 Rd. Marseliles. II. 61341 (Address) Date 03122/04 2. Sheet 1 of I Unit I WOl ARRR# R Repair Organization, P.O. No., Job No., etc. 3. Work Performed by-Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No. N/A (Name) Mechanical Maintenance (Address) Expiration Date_ N/A 4. 5. Identification of System (RH) Residual Heat Removal (a) Applicable Construction Code ANSI B31.1 19 73 Edition S74 Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-j989, No Ad, Code Cases None Identification of Comnonents Renaired or Reolaced. and Reolacement Comoonents R. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (1)- Load Stud PSA N/A IRH02-1067S Replaced NIA Assy (PSA-10) (1)- Load Stud BASIC-UTC # 2652241 N/A IRH02-1067S 2003 Replacement N/A Assy PSA Receipt # 82843 7. 8. 9. Description of Work: Class 2 Reolacement of Load stud assembly for a PSA-10 Mechanical Snubber. Tests Conducted: Hydrostatic I I Pneumatic I_ I Normal Operating Pressure I I Other Visual Pressure psi Test Temp. Deg. F Remarks: I = Per Orilonal Design Specification J-2530. (Applicable Manufacturer's Data Report to be Attached) CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and of the ASME Code, Section Xl. Type Code Symbol Stamp NONE this Replacement Sonforms to the rules (repair or replacement) Certificate of Authorization No. N/A Slanad e ISI Coordinator _Expiration Date N/A Date if 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issuedby the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR09 to LIRIO and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. iIAA;£ Commissions IL 1927 Inspebr's Signature NationalBoard, State, Province, and Endorsements Date J__ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. 2. Owner Exelon Generation Comranv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) nib6 vaOLe V IWWV' Sheet 1 of I Unit I W.O. # 518067 Repair Organization, P.O. No., Job No., etc. nFMQlnlA 3. Work Performed hv Mechanical Rlntenfannnea (Name) Mechanical Maintenance Type Code Symbol Stamp N/A Authorizatoln Nno NIA Expiration Date NIA (Address) 4. 5. 6. Identification of System (HP) Hiah Pressure Core Sprav (a) Appilcable Construction Code ANSI B31.1 19 73 Edition S74 Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989. No Ad, Code Cases None Identification of Comoonents Reoalred or Replaced. and Replacement Comoonents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (1) Nut for Support N/A HP07-1034X Replaced N/A Clamp (1) Nut for Support ITT Ht. Code 1Z75 N/A HP07-1034X 1987 Replacement N/A Clamp Grinell UTC # 2020166 7. 8. Description of Work: Class 2 Reolacement of one (1) missing load stud nut on strut HP07-1034X. Tests Conducted: Hydrostatic I I Pneumatic I _ I Normal Operating Pressure _ I Other Visual Pressure N/A [)sl Test Temp. N/A Deg. F Remarks: * = Per OrlaInal Deslan Soecificatlon J-2530. Reference Eva.1 M-1994-743-2. 9. (Applicable Manufacturer's Data Report to be Attached ) CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this of the ASME Code, Section XI. Type Code Symbol Stamp NONE 0 -6man - - c to the rules (repair or replacement) Certificate of Authorization No. Signed gn MIlA r nl %"x nt relyI I GLIWI N uaMW N/A A-ISI Coordinator Date °3 /t 9 . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. 8 Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to 1-R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. ____Commissions IL 1927 Insp04r's Signature National Board, State, Province, and Endorsements Date / F-2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl 1. Owner Exelon Generation Company IEGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles. II. 61341 (Address) a2fe /104ninA a WS v 2. Sheet 1 of I Unit I W.0 it 541754 3. Work Performed by_ Mechanical Maintenance Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date NIA (Name) Mechanical Maintenance 4. 5. A (Address) Identification of System (VQI Primary Containment Vent and Purae (a) Applicable Construction CodeASME Sect. Ill 1983 Edition S84 Addenda, Code Cases None (b) Applicable Edition of Sectlon Xl Utilized for Repairs or Replacements-1989 No Ad. Code Cases None Idrntifir-tlon of Comnonants Ranaired or Renlaced. and Renlacement Comnonents Name of Name of Mfrs. Ser. No. Nat'l Other Year Repaired ASME Code Component Mfr. Bd. Identification Bulit Replaced, or Stamped No. Replacement (Yes or No) Valve Body Bolt Clow SIN 2842-NIA Spare 1984 Repaired N/A Holes OIN-02 I= I= 7. 8. 9. Description of Work: Class 2 Revair of valve per DCP # 9900381 Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I_ I Other Visual-VT-1 Pressure __psi Test Temp.____Deg. F Remarks: Valve have elevated seat leakage rates. Modification was Performed by drilling thru the valve body bolt (Applicable Manufacturer's Data Report to be Attached) holes ver DCP #9900381 so that the valve can be mounted to the mating Plie flanae using through studs Instead of tapped holes and bolts. Twenty 120) of the 24 holes were drilled through. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Repair of the ASME Code, Section XI. (repair or rep Type Code Symbol Stamp NONE _conforms to the rules lacement) NIA Certificate of Authorization No. Signed .< 5E NIA .Expiration Date ISI Coordinator Date eY7/5t . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to LIR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 4,!) Commissions IL 1927 Inspep6r's Signature National Board, State, Province, and Endorsements Date 3 R 4 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. Owner Exelon Generation Companv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21 Rd. Marseilles. ii. 61341 (Address) Datp n0i1 nin _".W .w,__ 2. Sheet I of I Unit 1 WnO. # 541755 3. Work Performed bTI Maehanical MRAIn$annnea Repair Organization, P.O. No., Job No., etc. Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A (Name) Mechanical Maintenance (Address) 4. 5. Identification of System (VQ1 Primary Containment Vent and Purge (a) Applicable Construction Code ASME Sect. III 1983 Edition S84 Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989, No Ad. Code Cases None Identification of Components Repaired or Replaced, and Replacement Components 6. Name of Name of Mfrs. Ser. No. Nat'l Other Year Repaired ASME Code Component Mfr. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) Valve Body Bolt Clow S/N 2842-NIA Spare 1984 Repaired N/A Holes OIN-16 7. 8. 9. Description of Work: Class 2 Repalr of valve per DCP # 9900381 Tests Conducted: Hydrostatic l__I Pneumatic i i Normal Operating Pressure I I Other Visual-VT-1 Pressure psl Test Temp._Deg. F Remarks: Valve have elevated seat leakage rates. Modification was Derformed by drillina thru the valve body bolt (Applicable Manufacturer's Data Report to be Attached ) holes per DCP #9900381 so that the valve can be mounted to the mating vive flange using through studs Instead of tanned holes and bolts. Twentv (20) of the 24 holes were drilled through. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Repair of the ASME Code, Section Xl. (repair or rep Type Code Symbol Stamp NONE lacement) conforms to the rules Certificate of AuthrI tIon No. Signed liA r%.&-n am And=s~rd.g. NIA ISI Coordinator Date o-7 1-2, . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, Theundersigned, holding a valid commission Issuedby the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L1 R09 to LIRID and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions IL 1927 Inspolor's Signature National Board, State, Province, and Endorsements Date_ _ 3_2_ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name 2601 N. 21' Rd. Marseilles. II. 61341 Address Date 03/04104 Sheet 1 of I Unit 1 WO # 64421 Repair Organization, P.O. No., Job No., etc. 3. Work Performed hv Mge-hanineal Mainteannen (Name) Mechanical Maintenance Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date NIA 4. 5. (Address) Identification of System (RI) Reactor Core Isolation Cooling (a) Applicable Construction Code Sect ii 19 74 Edition NO Addenda, Code Cases NO (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89, No Ad, Code Cases NO
- 6.
Identification of Coin onents Repaired or Replaced, and Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. I Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) Flow Orifice NIA 1E51-D307 Replaced NIA Flow Orifice Consolidated Ht. # 054528-N/A 1E51-D307 2004 Replacement N/A Plate Power Supply 7130311 Recelpt #96126 I I I 7. 8. 9. Description of Work: Class 2 Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I X I Other Visual Pressure 1120 osl Test Temp. Ambient Deg. F Remarks: Existing orifice dlate with a hole diameter of 1.5" and causes excessive Initial flow was reolaced with a (Applicable Manufacturer's Data Report to be Attached ) new orifice plate with 1.25" hole diameter per EC # #346133. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and these Renlacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. NIA E Sinned eI L*. Mz ~ rnCordinatomr Expiration Date NIA Date °3 / 7 . 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period Ll R09 to 1-R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arls from or connected with this Inspection. Z Z 9L4. 1t./2.A Commissions IL 1927 Inspectfs Signature National Board, State, Province, and Endorsements Date 2 -/7 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Comnanv (EGC) LLC Date 03105/04 _ w w l 6 _ s _ A _. _.. _ _.. _. _ _.. _ _... _ _.. w w _ _ _. _ _ _ (Name) 200 Exelon Wav. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Sheet I of I Unit I 2. Name 2601 N. 21"' Rd. Marseilles. II. 61341 (Address) W.O. # 658780 Repair Organization, P.O. No., Job No., etc. 3. Work Performed h-. MMA_-- l UA-1-an my SCldld dll~llC (Name) Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. 5. 6. (Address) Identification of System (RH) Residual Heat Removal (a) Applicable Construction Code ANSI B31.1 19 73 Edition S74 Addenda, Code Cases None (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements-1989,.No Ad, Code Cases None Identification of ComDonents Reoalred or Replaced. and Renlacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) Pipe Support Morrison N/A FRH1216HOlX Repaired/ NIA Replaced (1) 3/4" dia. XXS NIA Ht. 671134 NIA FRH1216HO1X 1999 Replacement NIA Pipe A106 Gr. B (Receipt L99-01345) I (1) U-Bolt for 2" Anvil Fig. 137N N/A UTC 2676557 2003 Replacement N/A dia. pipe (Receipt # 126921) (1) Rear Bracket for PSA B087 N/A UTC 2688152 2004 Replacement N/A PSA 1/4 (Receipt # 96893) (1) 3/8" Thk. A-36 N/A Ht. J5317 NIA UTC # 2022574 1998 Replacement N/A Flat Bar (Receipt M98-02011) (1) 1/2" Thk. A-36 N/A Ht. 89021 N/A UTC # 2064025 2000 Replacement N/A Flat Bar (Receipt 55408) (. 8. Descnption OT Wo: MM mass Z Keoair ana Keolacemen OT vive Suvoort ver .~oob Tor mine I K 1,40-Z'. Tests Conducted: Hydrostatic I I Pneumatic _I_ Normal Operating Pressure I I Other Visual Pressure NIA Si Test Temp. N/A Deg. F Remarks: * = Per Original Design Soecificatlon J-2530. Pive suooort FRHI216HOIX was modified to reolace the 8. (Applicable Manufacturer's Data Report to be Attached ) existina clamo that was In contact with an adjacent Dpie. The clamp was replaced with a U-bolt. a PSA % rear 9. bracket and some mounting plates. The strut length was also changed within the tolerances of drawing IT-7000-M-PS-06. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and these Repair and Replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Slgned d X Ci 4 ISI Coordinator Date 3 ,// 9 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have inspected the components described In this Owner's Report during the period LI R09 to L1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arisi from or connected with this Inspection. , 4L Z Commissions IL 1927 Inspectol Signature National Board, State, Province, and Endorsements Date -3 1 7 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI 1. Owner Exelon Generation ComDanv (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Address Plant LaSalle County Nuclear Station Date 03/18104 Sheet 1 of I Unit I 2. Name 2601 N. 21" Rd. Marseilles. II. 61341 W.O. # 980107466-01 Repair Organization, P.O. No., Job No., etc. (Address) 3. W^,LSDarfx^I h 2l2rha lr A - - - - - - WVVUI FUn IIIUU My U "1n.% n..OI fVaImen (Name) Mechanical Maintenance (Address) Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. 5. Identification of System (RH) Residual Heat Removal (a) Applicable Construction Code ANSI B31.1 19 73 EditIon_.S/74W76 Addenda, Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements-1989, No Ad, Code Cases None Identification of Comoonents Renalred or Reolaced. and Reolacement Comoonents 6. Name of Name of Mfrs. Ser. Nat'l other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (1_ ) Load Stud Pacific N/A I RH03-1l044S Replaced NIA Sc1entific N (PSA-10) (1) Load Stud Pacific NIA N/A M94-00802 1 L94-1994 Replacement N/A Sclentific II__ 00996 1 7. 8. Description of Work: Class 2 Reviacement of Mechanical Snubber Load Stud Assemblv. Tests Conducted: Hydrostatic Id_1 Pneumatic I _I Normal Operating Pressure l _I Other Visual Pressure psI Test Temp.___.Deg. F Remarks: * = Per Oricanal Design Soecification J-2530. (Applicable Manufacturer's Data Report to be Attached) 9. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this of the ASME Code, Section XI. Type Code Symbol Stamp NONE -nfnn -o -the nylon (repair or replacement) Certificate of Authorization No. Signedg N/A Exnlratlon Date NIA C r. Date O 5Z/°2C . 2004 w, '..uuu.,,aIuu Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR08 to L1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty,expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. / p lbIf 4 A /- IA 1 Commissions IL 1927 Inspo tor's Signature National Board, State, Province, and Endorsements Date ________ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way, Kenneth Square. PA.. 19348 Address
- 2.
Plant LaSalle County Nuclear Station Name _ 2601 N. 21" Rd. Marseilles. II. 61341 Address Date 03115104 Sheet 1 of I Unit i W.O. #99008865 Repair Organization, P.O. No., Job No., etc. 3. Worlk Prfnromme hu Mechanical Man$Anfanne wave,W, (Name) Mechanical Maintenance Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date NIA (Address) 4. 5. identification of System (HP) High Pressure Core Spray (a) Applicable Construction Code Sect III 19 74 Edition No Addenda, Code Cases NO (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89_. No Ad, Code Cases N416-2 Identification of Comoonents Repalred or Replaced. and Reolacement Comoonents 6. Name of Name of Mfrs. Nat'l Other Year Repaired ASME Code Component Mfr. Ser. Bd. Identification Built Replaced, or Stamped No. No. Replacement (Yes or No) (1)-1.5" Inlet x 0.75" N/A 1E22+F349/F350 Replaced N/A outlet dia. C.S. Double Block Valve -_ (1)-1.5" x 0.75" dia. Chicago Ht. Code N/A UTC 2003691 1981 Replacement N/A C.S. Reducing Insert Tube and 0861 MRR # 5396 Iron 8. 9. Description of Work: Class 2 Replacement. I = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I X I Pneumatic I I Normal Operating Pressure l X I Other Visual Pressure 1290/420 osi TestTemp. 65.8/Amblent Deg.F Remarks:
- Replaced existing 1.5" X 0.75" dla. carbon steel double block valves with two (2) sinale 0.75" dia.
(Applicable Manufacturer's Data Report to be Attached ) carbon steel lobe valves. A new 1.5" x 0.75" dia. reducing Insert was Installed In order to reduce down the line for the new 0.75" dla. lobe valves and associated ololna. Replacement is per enalneerina chanae EC #51107. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this F of the ASME Code, Section Xl. (reF Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date _ Signed 6;>Go ISI Coordinator Date - Replacement conforms ialr or replacement) to the rules NIA 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to LR10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty,expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. b3Z "o 24,0 I "24 Commissions IL 1927 Inspeetr's Signature National Board, State, Province, and Endorsements Date 3-;z3-2 00 4
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi 1. Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Address Plant LaSalle County Nuclear Station Name 2601 N. 21" Rd. Marseilles, II. 61341 (Address) Date 03104104 2. Sheet of I Unit I Wn
- Q#9920A22461 Repair Organization, P.O. No., Job No., etc.
Type Code Symbol Stamp NIA A,,thnrl7llnn Non MIA 3. Work Performed by_ Mechanical Maintenance (Name) 1A.rnnle - - - - - -nr Expiration Date. NIA m¢Selalllwalmalmenarll;a (Address) 4. 5. Identification of System (RH) Residual Heat Removal (a) Applicable Construction Code ANSI B31.1 19 73 Edition S174 Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad, Code Cases None Idantlficatlon of Comnonents Renalred or Renlaced. and Renlacement Comnonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) (1) Load Stud Pacific NIA IRH19-1015S Replaced N/A Scientific (PSA-10) (1) Load Stud Pacific UTC # 2685660 N/A IRH19-1015S 2003 Replacement NIA Scientific (PSA-10) Receipt # 95097 7. 8. Description of Work: Class 2 Replacement of Mechanical Snubber Load Stud Assembly. Tests Conducted: Hydrostatic I..I Pneumatic I I Normal Operating Pressure II Other Visual Pressure spl Test Temp.___ Deg. F Remarks: * = Per Orlainal Deslan Soecificatlon J-2530. (Applicable Manufacturer's Data Report to be Attached) 9. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and of the ASME Code, Section Xi. Type Code Symbol Stamp NONE 0Dnle-vnan* f-un tin the n.Ili (repair or replacement) Va Certificate of Authorization No. Signed 6 4 ZIlA Renr:tln at roars1-- r.~l uz NIA ISI Coordinator Date -7 > . 2004 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Ililnois and employed by The Hartford Steam Boller Insy. & Ins. Co. of Connecticut have inspected the components described in this Owner's Report during the period I1R09 to L1R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arlsLfrom or connected with this Inspection. i/si Commissions IL 1927 Inspect Signature National Board, State, Province, and Endorsements Date vZ 3 272-2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1.
Owner Exelon Generation Company (EGC) LLC (Name) 200 Exelon Way. Kenneth Square, PA., 19348 Address
- 2.
Plant LaSalle County Nuclear Station Date 03104104 Name 260-1 N. 9114 Rd. Marselines l. 61341 Sheet 1 of I Unit I W.O. #99214139 Repair Organization, P.O. No., Job No., etc. Address 3. 4. 5. Work Performed bv Mech2nic-2a ManIn$eannen (Name) Mechanical Maintenance Type Code Symbol Stamp NIA Authorization No. NIA Expiration Date NIA (Address) Identification of System (1P) Low Pressure Core Spray (a) Appiicable Construction Code Sect _ii 19 74 Edition S175 Addenda, Code Cases NO (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-19 89. No Ad, Code Cases NO Identificatlon of Comronents Renalred or Renlaced. and Renlacement Comnonents 6. Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No) Relief Valve AG N60742-00-0002 N/A 1E21-F018 Replaced N/A Crosby Relief Valve AG N60742-00-0003 N/A 1E21-F018 2002 Replacement NIA Crosby I Receipt # 80073 1 1 Relief Valve AG N60742-00-0003 NIA 1E21.-FO1 2002 Repaired NIA Crosby I_ 7. 8. 9. Description of Work: Class 2 Repair & Replacement. * = Per N-5 Code Data Report on file at LaSalle County Station. Tests Conducted: Hydrostatic I I Pneumatic I __I Normal Operating Pressure l X I Other Visual Pressure 300 Osl Test Temp. Ambient Deg. F Remarks: New snare valve SN# N60742-00-0003 with documentation provided under Quality (Applicable Manufacturer's Data Report to be Attached ) Recelot #80073 was installed as a replacement for SN# N60742-00-0002 underwork order #99214139. Also. the repair portion of the work order Installed a testable flance detail to the discharge flange per IT-7000 drawings In order to Imorove the method of IST/ISI testing. CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and these Repair and Replacement conforms to the rules of the ASME Code, Section Xi. (repair or replacement) Type Code Symbol Stamp NONE Certificate of AuNo. Signed KllA r%-#-nnnn _________________IA,,,'f.1.aL NIA ISI Coordinator Date °03 / -OL / . 2004 Owner or Owner's Designee, Tltle CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issuedby the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller lnsp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LI R09 to LI-R10 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owner'sReport In accordance withthe requirements ofthe ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty,expressed or Implied, concerning the examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner foranypersonal Injury or property damage or a loss of any kind arising from or connected with this Inspection. l Commissions IL 1927 Inspector'sdlgnature National Board, State, Province, and Endorsements Date .3 - Y2 004 , I I :., - '., I. Z. ;, I 1, -7 1. I I.., I....
- 1. - '. -1. I i,
, - " .', , - t. -, -, , " ', t.! :,, i.4 -'Zu 'd, D !,. II L ;k,# ' L 4' i 2 ... 0% -A 7:,7. - 1'-,
- I' %-
- 14. I "
!.-.;-.... I - ,,,.;11 -,; Li-. , 3 -= Z 1.1 -.. - 7, 1-1-1 - Z-
- m.. -..WR NV 1 FOR &Jt
.AND &48U EY 2tVALV l,S 'g~t h-t" '$; As.' ftqW by ' d-'hw of the AD Cod -'~e'.s;. himX g s @8-DATA RE, AE W '0-; 11.EILON OENERATN COIMPANY O oOh3511,11146 :t- - Wa =n dd e t iii 4, ,4,, ,4, T. t e 4Q .Yi -SPAREL SaW Nm N2MM Dmb No. D;4724
- ryr SaF~YRLE.
Orficg 1.630 pvc.,, = M;, ., ).le t (Pm^ ,d, Ge 100
- 6 o,,L ;
- 6 w
"W C a&, ;od M'.
- d on-;Jlcf C cN.
1 Al-q' F< wi >16X; am et Pm r J Ww l _tte4. j g;0-s 1 -.7 i i -f s.0>4 .a^ .9id &ek. <49,;'§ v,° tj -
- t I
I 1 He I. I-
-' M -7 Form NV-I (Back) Certiflcate Holder's Serial No. N60742-OD-0003
- 'v-
.¶ Q.C.44C-I Mer Spepitcatwn bctding Type or Grade INCONEL X750 rJ Serial No. n 4if1a40on NX3145 0003
- c. Spring
- d. Boiling
- c. Other Pau such u Pilot Components BONNET STUD N95995 ASME SA193 GR.B7 BONNET NUT N95987 ASME SA194 GR.2H We certifY d the eMet made in dhis report are correct.
Aadero Geenwod Cosby Dsftc _ 5 -__ A 20 _Sig__e Wreham, MA By --no. 1s Manufacturer Cerifice of Authorization No. N-1878 Expires Sep. 30. 2004 Date 2 CER TlEICA f OF SHOPM
- 1. &c udesnd. d uding a uid cominn issud by te Naiowl Bard o Boie ad Presr Vesnd d _e Sw or Prvc ofMasM. And eaqoyed by Fatory MuUa Insurance Co., Johnson, RM hve inspected the equipmen described i this Dat Report oan U
La:$ ? 20 O.? and Ste that o the beg of my an lkf the M h this Ulpme in accordae with the a be Subsection of ASME Section IH. By signing this cerficate, neither the nspector nor his emplyer makes any warranty. exp edw impied Concerning the equipment described i this Daa Report. Furthermore, neither the Inspector n his ernployr sal be liable in any manner for any personal injury or property damage or a loss of any kind ariing from or coomected with this inspection. e H~s-rms N20 Commisson (National Board, Stte. Province and No.)
- 4
, i .1, 'i,
- )
ei..
ATTACHMENT 3 ABBREVIATIONS AD ADDENDA ANIC AUTHORIZED NUCLEAR INSERVICE CONCRETE AISI AUGMENTED INSERVICE INSPECTIONS ASSY ASSEMBLY ATT ATTACHMENT ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS AUTO UT AUTOMATED ULTRASONIC TEST BOM BILL OF MATERIAL BWROG BOILING WATER REACTOR OWNER'S GROUP BWRVIP BOILING WATER REACTOR VESSEL AND INTERNALS PROJECT CHRON TRACKING SYSTEM FOR ENGINEERING EVALUATIONS CID CATALOG IDENTIFICATION CM CONTAINMENT MONITERING CISI CONTAINMENT INSERVICE INSPECTION CR COMPONENT RELIEF REQUEST CRD CONTROL ROD DRIVE EC ENGINEERING CHANGE ED EDITION EGC EXELON GENERATION COMPANY ES EXTRACTION STEAM EVT ENHANCED VISUAL TEST FC FUEL POOL COOLING FW FEEDWATER GENE GENERAL ELECTRIC NUCLEAR ENERGY HG CONTAINMENT COMBUSTIBLE GAS CONTROL HP HIGH PRESSURE CORE SPRAY HSB-CT HARTFORD STEAM BOILER INSPECTION & INSURANCE CO. OF CONNECTICUT HT# HEAT NUMBER
ATTACHMENT 3 (CONT'D) ID/OD INSIDE DIAMETER/OUTSIDE DIAMETER IGSCC INTERGRANULAR STRESS CORROSION CRACKING IL ILLINOIS IN INSTRUMENT NITROGEN IRM INTERMEDIATE RANGE MONITOR ISI INSERVICE INSPECTION LiF35 LASALLE ONE FORCED OUTAGE 35 LIR08 LASALLE ONE REFUEL OUTAGE EIGHT LIR09 LASALLE ONE REFUEL OUTAGE NINE LIR10 LASALLE ONE REFUEL OUTAGE TEN LLC LIMITED LIABILITY COMPANY LPRM LOCAL POWER RANGE MONITOR LP LOW PRESSURE CORE SPRAY MIL MILLIMETER MC CLEAN CONDENSATE STORAGE MS MAIN STEAM MSIV MAIN STEAM ISOLATION VALVE MT MAGNETIC PARTICLE TEST N/A NOT APPLICABLE NB NUCLEAR BOILER NDE NON-DESTRUCTIVE EVALUATION NDES NONDESTRUCTIVE EXAMINATION SERVICES NIR NOZZLE INNER RADIUS NR NUCLEAR INSTRUMENTATION NRC NUCLEAR REGULATORY COMMISSION NRI NON-RECORDABLE/NON-RELEVANT INDICATION PA PENNSYLVANIA PC PRIMARY CONTAINMENT PCE PART CLASSIFICATION EVALUATION PDI PERFORMANCE DEMONSTRATION INITIATIVE
ATTACHMENT 3 (CONT'D) PG PAGE PO PURCHASE ORDER PR PRESSURE TESTING RELIEF REQUEST PSI PRESERVICE INSPECTION PSIG POUNDS PER SQUARE INCH GAGE PT LIQUID PENETRANT TEST PTE PART TECHNICAL EVALUATION QRI QUALITY RECEIPT INSPECTION RC-PB REACTOR COOLANT PRESSURE BOUNDARY RD ROD DRIVE RE REACTOR BUILDING EQUIPMENT DRAINS RF REACTOR BUILDING FLOOR DRAINS RH RESIDUAL HEAT REMOVAL RI REACTOR CORE ISOLATION COOLING RIN RECEIPT INSPECTION NUMBER RPV REACTOR PRESSURE VESSEL RR REACTOR RECIRCULATION RT REACTOR WATER CLEAN-UP SA SERVICE AIR SAR SAFETY ANALYSIS REPORT SC STANDBY LIQUID CONTROL SDC SHUTDOWN COOLING SEAG SITE ENGINEERING ADMIN GROUP SIL SERVICES INFORMATION LETTER SRM SOURCE RANGE MONITOR SRV SAFETY RELIEF VALVE STM STEAM UT ULTRASONIC TEST VG STANDBY GAS TREATMENT VLV VALVE
ATTACHMENT 3 (CONT'D) VP PRIMARY CONTAINMENT CHILLED WATER VQ PRIMARY CONTAINMENT VENT AND PURGE VT VISUAL TEST WO WORK ORDER WR REACTOR BUILDING CLOSED COOLING WATER}}