SECY-04-0053, 2003 External Stakeholder Response to Federal Register Notice, Solicitation of Public Comments on Fourth Year of Implementation of Reactor Oversight Process

From kanterella
(Redirected from ML041190018)
Jump to navigation Jump to search
2003 External Stakeholder Response to Federal Register Notice, Solicitation of Public Comments on Fourth Year of Implementation of Reactor Oversight Process
ML041190018
Person / Time
Issue date: 04/28/2004
From: Richards S
NRC/NRR/DIPM/IIPB
To: Bauer S, Burzynski M, Carlin R, Crocker G, Epstein E, Funderburk C, Howey N, Janati R, Krupa M, Lochbaum D, Mcburnett M, Navarrete F, Pietrangelo A, Riccio J, Scherer A, Vassello J, Weinkam E, Woodlan D
Dominion Resources, Entergy Operations, Greenpeace, North American Water Office, Nuclear Energy Institute, Nuclear Management Co, Public Service Enterprise Group, Region IV Utility Group (RUG IV), South Texas, Southern California Edison Co, State of AZ, Div of Emergency Management, State of IL, Emergency Management Agency, State of PA, Dept of Environmental Protection, Strategic Teaming & Resource Sharing (STARS), Tennessee Valley Authority, Three Mile Island Alert, Union of Concerned Scientists
Frahm, R K, NRR/DIPM/IIPB, 415-2986
Shared Package
ML041190322 List:
References
SECY-04-0053
Download: ML041190018 (27)


Text

April 28, 2004 David Lochbaum Nuclear Safety Engineer Union of Concerned Scientists 1707 H Street, NW Suite 600 Washington, DC 20006-3962

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Lochbaum:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

April 28, 2004 Rich Janati, Chief Division of Nuclear Safety, Bureau of Radiation Protection PA Department of Environmental Protection P.O. Box 8469 400 Market Street Harrisburg, PA 17105-8469

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Janati:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

Michael A. Krupa, Director April 28, 2004 Nuclear Safety & Licensing Entergy Operations, Inc.

1340 Echelon Parkway Jackson, MS 39213-8298

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Krupa:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

C. L. Funderburk, Director April 28, 2004 Nuclear Licensing and Operations Support Dominion Resources Services, Inc.

5000 Dominion Boulevard Glen Allen, VA 23060

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Funderburk:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

Mark McBurnett April 28, 2004 Manager, Quality and Licensing South Texas Project Nuclear Operating Company P.O. Box 289 Wadsworth, TX 77483

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. McBurnett:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

George Crocker April 28, 2004 Executive Director North American Water Office P.O. Box 174 Lake Elmo, MN 55042

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Crocker:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

D. R. Woodlan, Chairman April 28, 2004 Integrated Regulatory Affairs Group Strategic Teaming and Resource Sharing (STARS)

P.O. Box 1002 Glen Rose, TX 76043

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Woodlan:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

Eric Joseph Epstein April 28, 2004 Coordinator of EFMR Monitoring Group, Inc.

Chairman of Three Mile Island Alert, Inc.

4100 Hillsdale Road Harrisburg, PA 17112

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Epstein:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

Edward J. Weinkam April 28, 2004 Director, Regulatory Services Nuclear Management Company, LLC 700 First Street Hudson, WI 54016

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Weinkam:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

A. Edward Scherer April 28, 2004 Manager of Nuclear Regulatory Affairs Southern California Edison P.O. Box 128 San Clemente, CA 92674-0128

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Scherer:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

Neill Howey April 28, 2004 Senior Policy Analyst Illinois Emergency Management Agency Bureau of Nuclear Facility Safety 1035 Outer Park Drive Springfield, IL 62704

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Howey:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

Anthony R. Pietrangelo April 28, 2004 Senior Director, Risk Regulation Nuclear Generation Nuclear Energy Institute (NEI) 1776 I Street, NW Suite 400 Washington, DC 20006-3708

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Pietrangelo:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

John Carlin April 28, 2004 Vice President - Nuclear Assessments PSEG Nuclear LLC P. O. Box 236 Hancocks Bridge, NJ 08038-0236

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Carlin:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

James V. Vassello, P. E.

April 28, 2004 TRENDS Program Manager 2650 McCormick Drive, Suite 300 Clearwater, FL 33759-1049

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Vassello:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

Mark J. Burzynski April 28, 2004 Manager, Nuclear Licensing Tennessee Valley Authority 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Burzynski:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

James Riccio April 28, 2004 Nuclear Policy Analyst Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Riccio:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). Although you did not specifically respond to this FRN, the NRC considered your comments provided at the Commission briefing on May 15, 2003, along with comments from 17 other stakeholders that responded to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and evaluates the comments when considering changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

Frank F. Navarrete, Director April 28, 2004 Arizona Division of Emergency Management 5636 East McDowell Road Phoenix, AZ 85008-3495

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Navarrete:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

April 28, 2004 S. A. Bauer, Chairman Region IV Utility Group 4200 South Hulen Drive Suite 630 Ft. Worth, TX 76109

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Bauer:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated

David Lochbaum April 28, 2004 Nuclear Safety Engineer Union of Concerned Scientists 1707 H Street, NW Suite 600 Washington, DC 20006-3962

SUBJECT:

2003 EXTERNAL STAKEHOLDER RESPONSE TO FEDERAL REGISTER NOTICE, SOLICITATION OF PUBLIC COMMENTS ON THE FOURTH YEAR OF IMPLEMENTATION OF THE REACTOR OVERSIGHT PROCESS

Dear Mr. Lochbaum:

On November 5, 2003, the Nuclear Regulatory Commission (NRC) issued a Federal Register notice (FRN) soliciting comments on the fourth year of implementation of the Reactor Oversight Process (ROP). The NRC received your comments as well as comments from 17 other external stakeholders and/or organizations in response to this FRN. The NRC welcomes these comments, as they provide perspectives on how external stakeholders view the effectiveness of the ROP, and considers these comments when evaluating changes to the ROP.

The staff issued SECY-04-0053, Reactor Oversight Process Self-Assessment for Calendar Year 2003," dated April 6, 2004, to present the results of the staffs annual self-assessment of the ROP. The annual self-assessment uses several diverse data sources, including feedback from internal and external stakeholders, objective metrics, and recommendations from independent evaluations. Although this paper does not directly address every comment received in response to the FRN, all comments were considered and many of the comments have been addressed throughout the paper. In particular, staff analysis of the survey responses is included in the applicable portions of the program area discussions in as well as the ROP performance metric report in Attachment 3. In addition, an overview of the external survey results is contained in Attachment 4.

A copy of the paper is enclosed for your convenience, and is also available through the NRCs Agencywide Documents Access and Management System (reference accession number ML040620267) or through the electronic reading room of the NRC Web page at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2004. The self-assessment conclusions will be presented to the Commission in a public meeting on May 4, 2004.

The staff appreciates your efforts to provide comments. Should you have any questions, please contact Mr. Ronald K. Frahm at 301-415-2986 or by e-mail at rkf@nrc.gov.

Sincerely,

/RA/

Stuart A. Richards, Chief Inspection Program Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation

Enclosure:

As stated Identical letters sent to: See Next Page Distribution:

IIPB r/f Pkg: ML041190322 Letter - Accession Number: ML041190018 SECY Paper: ML040500592 Att 1: ML040510118 Att 2: ML040510132 Att 3: ML040510165 Att 4: ML040510183 Att 5: ML040510195 Att 6: ML040510233 Att 7: ML040510264 OFFICE DIPM/IIPB DIPM/IIPB:SC DIPM/IIPB:BC NAME RFrahm JAndersen SRichards DATE 04/28/04 04/28/04 04/28/04 OFFICIAL RECORD COPY

cc:

David Lochbaum Nuclear Safety Engineer Union of Concerned Scientists 1707 H Street, NW Suite 600 Washington, DC 20006-3962 Rich Janati, Chief Division of Nuclear Safety, Bureau of Radiation Protection PA Department of Environmental Protection P.O. Box 8469 400 Market Street Harrisburg, PA 17105-8469 Michael A. Krupa, Director Nuclear Safety & Licensing Entergy Operations, Inc.

1340 Echelon Parkway Jackson, MS 39213-8298 C. L. Funderburk, Director Nuclear Licensing and Operations Support Dominion Resources Services, Inc.

5000 Dominion Boulevard Glen Allen, VA 23060 Mark McBurnett Manager, Quality and Licensing South Texas Project Nuclear Operating Company P.O. Box 289 Wadsworth, TX 77483 George Crocker Executive Director North American Water Office P.O. Box 174 Lake Elmo, MN 55042 D. R. Woodlan, Chairman Integrated Regulatory Affairs Group Strategic Teaming and Resource Sharing (STARS)

P.O. Box 1002 Glen Rose, TX 76043 Eric Joseph Epstein Coordinator of EFMR Monitoring Group,Inc.

Chairman of Three Mile Island Alert, Inc.

4100 Hillsdale Road Harrisburg, PA 17112 S. A. Bauer, Chairman Region IV Utility Group 4200 South Hulen Drive Suite 630 Ft. Worth, TX 76109 Edward J. Weinkam Director, Regulatory Services Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 A. Edward Scherer Manager of Nuclear Regulatory Affairs Southern California Edison P.O. Box 128 San Clemente, CA 92674-0128 Neill Howey Senior Policy Analyst Illinois Emergency Management Agency Bureau of Nuclear Facility Safety 1035 Outer Park Drive Springfield, IL 62704 Anthony R. Pietrangelo Senior Director, Risk Regulation Nuclear Generation Nuclear Energy Institute (NEI) 1776 I Street, NW Suite 400 Washington, DC 20006-3708 John Carlin Vice President - Nuclear Assessments PSEG Nuclear LLC P. O. Box 236 Hancocks Bridge, NJ 08038-0236 James V. Vassello, P. E.

TRENDS Program Manager 2650 McCormick Drive, Suite 300 Clearwater, FL 33759-1049 Mark J. Burzynski Manager, Nuclear Licensing Tennessee Valley Authority 1101 Market Street Chattanooga, TN 37402-2801

James Riccio Nuclear Policy Analyst Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001 Frank F. Navarrete, Director Arizona Division of Emergency Management 5636 East McDowell Road Phoenix, AZ 85008-3495