ML022740619
| ML022740619 | |
| Person / Time | |
|---|---|
| Site: | Ginna |
| Issue date: | 10/01/2002 |
| From: | Luehman J, David Nelson NRC/OE |
| To: | |
| Nelson D | |
| References | |
| EA-02-141 EN-02-050 | |
| Download: ML022740619 (2) | |
Text
PRELIMINARY INFORMATION - NOT FOR PUBLIC DISCLOSURE UNTIL VERIFICATION THAT LICENSEE HAS RECEIVED ACTION October 1, 2002 EN-02-050 OFFICE OF ENFORCEMENT NOTIFICATION OF SIGNIFICANT ENFORCEMENT ACTION Licensee:
Rochester Gas and Electric Corporation (EA-02-141)
R.E. Ginna Nuclear Power Plant Docket No. 50-244
Subject:
ISSUANCE OF FINAL SIGNIFICANCE DETERMINATION AND NOTICE OF VIOLATION This is to inform the Commission that a WHITE Significance Determination Process (SDP) finding and associated Notice of Violation will be issued on or around October 4, 2002, to Rochester Gas and Electric Corporation as a result of inspections at the Ginna Nuclear Power Plant. This WHITE finding, an issue with low to moderate increased importance to safety, which may require additional NRC inspections, involved the alert and notification system (ANS),
which consists of sirens used to alert members of the public of an emergency at Ginna.
Specifically, problems with the ANS siren feedback system prevented the licensee and Monroe and Wayne Counties from being able to identify which, if any, sirens failed to activate which would have impacted the licensees ability to commence route alerting. This condition represented a violation of 10 CFR Part 50, Appendix E. Accordingly, a Notice of Violation associated with a WHITE finding is being issued.
It should be noted that the licensee has not been specifically informed of this action. The schedule of issuance and notification are:
Mailing of Final Significance Determination and Notice of Violation October 4, 2002 Telephone Notification of licensee October 4, 2002 The State of New York will be informed.
Contacts:
D.J. Nelson, OE, 415-3280 J. Luehman, OE, 415-2741 Distribution:
OWFN Chairman Meserve Comm. Dicus Comm. Diaz Comm. McGaffigan Comm. Merrifield SECY OCA PA IP OWFN EDO DEDR DEDE OE OGC NRR NSIR OI SP TWFN OCFO OP CENTER NMSS OIG OCIO RES ACRS Regional Offices RI RII RIII RIV MAIL ADAMS OE:ES OE:DD DJNelson JLuehman 10/ /2002 10/ /2002 File Name:G:\\OECASES\\EN-02-050.Ginna.djn.wpd ADAMS ACN. ML022740619