Table Partial 1 North Anna Unit 2 Reactor Vessel Outlet Nozzle to Shell Welds 10, 12, and 14 Aggregate Coverage Percentage Estimates Category B-D, Item B-3.90 Weld Volume Weld Volume 100 60.5 100 60.5 100 100 Weld = 1(

Weld Volume 100 100 10 Degrees 45 Degrees 50 Degrees 60 Degrees 70 De grees 80 De grees 100 60.5 1 00 60.5 100 60.5 100 60.5 100 60.5 100 60.5

)0%

Volume = 60.5%

Combined Average 80.25%

1 The bore exams provide 100% coverage for the axial scan direction, which accounts for 50% of the required scans.

These bore exams combined with the transverse scan average of 60.5% results in a combined coverage for the volume of 80.25%. Weld coverage of 100% was calculated separately.

Beam Direction CCW CW Bore Axial Average of All Weld Volume I

Weld Volume Weld Volume

Sketch Partial 1 North Anna Unit 2 Reactor Vessel Outlet Nozzle to Shell Welds 10, 12, and 14 NOZZLE 0', 180' VOLUME EXAMINED -

69/

NOZZLE BOSS vEXAM VOLUNE