PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 MAY 0 2 2002 LR-N02-0177 0

PSEG N, uclear LLC United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

STEAM GENERATOR TUBE PLUGGING REPORT TECHNICAL SPECIFICATION 4.4.6.5.a SALEM GENERATING STATION UNIT NO. 2 FACILITY OPERATING LICENSE DPR-75 DOCKET NO. 50-311 PSEG Nuclear, LLC hereby submits the steam generator tube plugging report for Salem Generating Station, Unit No. 2 as required by Technical Specification 4.4.6.5.a for Facility Operating License DPR-75. The Steam Generator Tube inspections were completed on April 28, 2002 during the Unit 2 1 2 th refueling outage (2R12).

A total of forty-one (41) tubes were plugged during 2R12. The following is a summary of the tubes plugged as a result of eddy current inspections:

Steam Generator #21 -

14 tubes Steam Generator #22 -

8 tubes Steam Generator #23 -

10 tubes Steam Generator #24 -

9 tubes The total Salem Unit No. 2 steam generator tube plugging is 6.73%

Should there be any questions regarding this submittal, please contact Michael G.

Mosier at (856) 339-5434.

Mabonr Sal on Manager Nuclear Safety and Licensing 95-2168 REV. 7/99

Document Control Desk 2

MAY 0 2 ZOQZ LR-N02-0177 C:

Mr. H. J. Miller, Administrator - Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 U. S. Nuclear Regulatory Commission ATTN: Mr. R. Fretz, Project Manager - Salem Mail Stop 08B1A Washington, DC 20555-001 USNRC Senior Resident Inspector - Salem (X24)

Mr. K. Tosch, Manager IV Bureau of Nuclear Engineering 33 Arctic Parkway CN 415 Trenton, NJ 08625