L-MT-05-042, ODCM-APP-C, Rev 0, Appendix C
| ML051360179 | |
| Person / Time | |
|---|---|
| Site: | Monticello |
| Issue date: | 05/09/2005 |
| From: | Thomas J. Palmisano Nuclear Management Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-MT-05-042 ODCM-APP-C, Rev 0 | |
| Download: ML051360179 (5) | |
Text
APPENDIX C Revision 0 ODCM-APP-C MONTICELLO NUCLEAR GENERATING PLANT TITLE:
Page 1 of 5 I/plr OFFSITE DOSE CALCULATION MANUAL - TABLE OF CONTENTS SECTION PAGE 1.0 RECORD OF REVISION 2
Table 1 Parameters for Cow and Goat Milk Pathways 3
Table 2 Parameters for the Cow Meat Pathway 4
Table 3 Parameters for the Vegetable Pathway 5
OC Final Review Meeting:
Prepared By:
Approved By Plant Manager:
Reviewed By:
Date:
Date:
Resp Supv:
CHEM Assoc Ref:
SR:
2 yrs N
Freq:
CHEM-I ARMS:
ODCM-APP-C Doc Type:
Admin Initials:
Date:
7030 FOR ADMINISTRATIVE USE ONLY 3087 (DOCUMENT CHANGE, HOLD, AND COMMENT FORM) incorporated:
APPENDIX C Revision 0 ODCM-APP-C MONTICELLO NUCLEAR GENERATING PLANT TITLE:
Page 2 of 5 I/plr 1.0 RECORD OF REVISION Revision No.
Date Reason for Revision 0
October - 2000 Moved previous ODCM-10.01 tables of parameters to this document.
APPENDIX C Revision 0 ODCM-APP-C MONTICELLO NUCLEAR GENERATING PLANT TITLE:
Page 3 of 5 I/plr Table 1 Parameters for Cow and Goat Milk Pathways Parameter Value Reference in Reg. Guide 1.109 Rev. 1 QF (kg/day) 50 (cow) 6 (goat)
Table E-3 Table E-3 tf (seconds) 1.73 X 105 (2 days)
Table E-15 r
1.0 (radioiodines) 0.2 (particulates)
Table E-15 Table E-15 (DFLi)a (mrem/pCi)
Each radionuclide Table E-11 to E-14 Fm (pCi/day per pCi/liter)
Each stable element Table E-1 (cow)
Table E-2 (goat) tb (seconds) 4.73 X 108 (15 yr)
Table E-15 Ys(kg/m2) 2.0 Table E-15 Yp (kg/m2)
.75 Table E-15 th (seconds) 7.78 X 106 (90 days)
Table E-15 Uap (liters/yr) 330 infant 330 child 400 teen 310 adult Table E-5 Table E-5 Table E-5 Table E-5 tep (seconds) 2.59 X 106 (pasture)
Table E-15 tes (seconds) 5.18 X 106 (stored feed)
Table E-15 Biv (pCi/kg (wet weight) per pCi/kg (dry soil))
Each stable element Table E-1 P (kg dry soil/m2) 240 Table E-15
APPENDIX C Revision 0 ODCM-APP-C MONTICELLO NUCLEAR GENERATING PLANT TITLE:
Page 4 of 5 I/plr Table 2 Parameters for the Cow Meat Pathway Parameter Value Reference in Reg. Guide 1.109 Rev. 1 r
1.0 (radioiodines) 0.2 (particulates)
Table E-15 Table E-15 Ff (pCi/kg per pCi/day)
Each stable element Table E-1 Uap (kg/yr) 0 infant 41 child 65 teen 110 adult Table E-5 Table E-5 Table E-5 Table E-5 (DFLi)a (mrem/pCi)
Each radionuclide Table E-11 to E-14 Yp (kg/m2) 0.7 Table E-15 Ys(kg/m2) 2.0 Table E-15 tb (seconds) 4.73 X 108 (15 yr)
Table E-15 ts (seconds) 1.73 X 106 (20 days)
Table E-15 th (seconds) 7.78 X 106 (90 days)
Table E-15 tep (seconds) 2.59 X 106 (pasture)
Table E-15 tes (seconds) 5.18 X 106 (stored feed)
Table E-15 QF (kg/day) 50 Table E-3 Biv (pCi/kg (wet weight) per pCi/kg (dry soil))
Each stable element Table E-1 P (kg dry soil/m2) 240 Table E-15
APPENDIX C Revision 0 ODCM-APP-C MONTICELLO NUCLEAR GENERATING PLANT TITLE:
Page 5 of 5 I/plr Table 3 Parameters for the Vegetable Pathway Parameter Value Reference in Reg. Guide 1.109 Rev. 1 r (dimensionless) 1.0 (radioiodines) 0.2 (particulates)
Table E-1 Table E-1 (DFLi)a (mrem/Ci)
Each radionuclide Tables E-11 to E-14 ULa (kg/yr) 0 Infant 26 Child 42 Teen 64 Adult Table E-5 Table E-5 Table E-5 Table E-5 Usa (kg/yr) 0 Infant 520 Child 630 Teen 520 Adult Table E-5 Table E-5 Table E-5 Table E-5 tL (seconds) 8.6 X 104 (1 day)
Table E-15 th (seconds) 5.18 X 106 (60 days)
Table E-15 Yv (kg/m2) 2.0 Table E-15 te (seconds) 5.18 X 106 (60 days)
Table E-15 tb (seconds) 4.73 X 108 (15 yr)
Table E-15 P (kg/(dry soil)/m2) 240 Table E-15 Biv (pCi/kg(wet weight) per pCi/kg (dry soil))
Each stable element Table E-1