L-2003-112, Annual Radiological Environmental Operating Report

From kanterella
Jump to navigation Jump to search
Annual Radiological Environmental Operating Report
ML031350617
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 05/08/2003
From: Jones T
Florida Power & Light Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2003-112
Download: ML031350617 (60)


Text

FPL MAY 2003 L-2003-112 10 CFR 50.36b U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C. 20555-00001 Re:

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 2002 Annual Radiological Environmental Operating Report Enclosed is the 2002 Annual Radiological Environmental Operating Report for Turkey Point Units 3 and 4, as required by Technical Specification 6.9.1.3.

Should there be any questions or comments regarding this information, please contact Walter Parker at (305) 246-6632.

Sincerely, Terry

. Jones Vice President Turkey Point Plant SM Enclosure NRC Regulatory Issue Summary 2001-05 waived the requirements that multiple copies of documents be submitted to the NRC.

I,

-5 an FPL Group company

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT UNITS 3 & 4 LICENSE NOS. DPR-31, DPR-41 DOCKET NOS. 50-250, 50-251 Data Submitted by: Florida DOH Prepared by:

9-4N Reviewed by:

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 TABLE OF CONTENTS DESCRIPTION Introduction Radiological Environmental Monitoring Program Discussion and Interpretation of Results

-Environmental Radiological Monitoring Program Annual Summary Deviations / Missing Data Analyses with LLDs Above Required Detection Capabilities Land Use Census Key to Sample Locations Radiological Surveillance of Florida Power and Light Company's Turkey Point Site First Quarter, 2002 Second Quarter, 2002 Third Quarter, 2002 Fourth Quarter, 2002 Results from the Interlaboratory Comparison Program, 2002 PAGE 1

1 3

TABLE 1 TABLE 1A TABLE 1B TABLE 2 ATTACHMENT A ATTACHMENT B ATTACHMENT C i

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 EXECUTIVE

SUMMARY

The data obtained through the Turkey Point Radiological Environmental Monitoring Program verifies that the levels of radiation and concentrations of radioactive materials in environmental samples are not increasing. These measurements verify that the dose or dose commitment to members of the public, due to operation of Turkey Point Units 3 & 4, during the surveillance year, is well within the limits established by 10 CFR 50, Appendix I. The sampling period was from January 1, 2002 to December 31, 2002.

Additionally, supplemental samples collected by the State of Florida, DOH, do not indicate adverse trends in the radiological environment.

ii

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 INTRODUCTION This report is submitted pursuant to Specification 6.9 of Turkey Point Units 3 & 4 Technical Specifications. The Annual Radiological Environmental Operating Report provides information, summaries and analytical results pertaining to the Radiological Environmental Monitoring Program for the calendar year indicated. This report covers surveillance activities described in the Offsite Dose Calculation Manual (ODCM) meeting the requirements of Unit 3 and Unit 4 Technical Specifications.

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM A.

Purpose The purpose of the Radiological Environmental Monitoring Program is to provide representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides which lead to the highest potential radiation exposures of members of the public resulting from station operation. The Radiological Environmental Monitoring Program also supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways.

B.

Program Description The Radiological Environmental Monitoring Program (REMP) for the Turkey Point Plant is conducted pursuant to Control 5.1 of Turkey Point Unit 3 & 4 ODCM.

1.

Sample Locations, Types and Frequencies:

a.

Direct radiation gamma exposure rate is monitored continuously at 21 locations by thermoluminescent dosimeters (TLDs). TLDs are collected and analyzed quarterly.

b.

Airborne radioiodine and particulate samplers are operated continuously at five locations. Samples are collected and analyzed weekly. Analyses include Iodine-131, gross beta, and gamma isotopic measurements.

c.

Surface water samples are collected from three locations. Samples are collected and analyzed monthly. Analyses include gamma isotopic and tritium measurements.

1

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4

d.

Shoreline sediment samples are collected from three locations coinciding with the locations for surface water samples. Samples are collected and analyzed semi-annually. Sediment samples are analyzed by gamma isotopic measurements.

e.

Fish and invertebrate samples are collected from two locations coinciding with two of the locations for surface water samples. Samples are collected and analyzed semi-annually.

Fish and invertebrate samples are analyzed by gamma isotopic measurements.

f.

Broad leaf vegetation samples are collected from three locations.

Samples are collected and analyzed monthly.

Broad leaf vegetation samples are analyzed by gamma isotopic measurements.

Attachment A provides specific information pertaining to sample locations, types and frequencies.

2.

Analytical Responsibility:

Radiological environmental monitoring for the Turkey Point Plant is conducted by the State of Florida, Department of Health (DOH). Samples are collected and analyzed by DOH personnel.

Samples are analyzed at the DOH Environmental Radiation Control Laboratory in Orlando, Florida.

C.

Analvtical Results Table 1, Environmental Radiological Monitoring Program Annual Summarv provides a summary for all specified samples collected during the referenced surveillance period.

Deviations from the sample schedule, missing data and/or samples not meeting the specified "A PRIORI" LLD, if any, are noted and explained in Tables 1A and 1B respectively. Analysis data for all specified samples analyzed during the surveillance period is provided in Attachment B.

D.

Land Use Census A land use census out to a distance of 5 miles radius from the Turkey Point Plant is conducted annually to determine the location of the nearest milk animal, residence, and garden producing broad leaf vegetation, in each of the sixteen meteorological sectors.

A summary of the land use census for the surveillance year is provided in Table 2, Land Use Census Summarv.

2

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 E.

Interlaboratorv ComDarison Program The intercomparison program consists of participating in the Department of Energy's EML New York Quality Assessment Program (DOE-QAP). The DOE-QAP consists of two rounds of Air Filter, Water, Soil, and Vegetation matrices.

The samples are analyzed using the methods applicable to the REMP ( gamma spectroscopy, Gross Beta, and Tritium for water ). The results for nuclides associated with the REMP are listed in ATTACHMENT C, RESULTS FROM THE INTERLABORATORY COMPARISON PROGRAM.

Ill.

DISCUSSION AND INTERPRETATION OF RESULTS A.

Reporting of Results The Annual Radiological Environmental Operating Report contains the summaries, interpretations and information required by Control 1.4 of ODCM. Table 1 provides a summary of the measurements made for the nuclides required by ODCM Table 5.1-2, for all samples specified by Table 5.1-1. In addition, summaries are provided for other nuclides identified in the specified samples, including those not related to station operation. These include nuclides such as K-40, Th-232, Ra-226, and Be-7 which are common in the Florida environment.

B.

Interpretation of Results

1.

Direct Radiation:

The results of direct radiation monitoring are consistent with past measurements for the specified locations.

The exposure rate data shows no indication of any trends attributed to effluents from the plant. The measured exposure rates are consistent with exposure rates that were observed during the pre-operational surveillance program.

Direct radiation monitoring results are summarized in Table 1.

2.

Air Particulates/Radioiodine:

The results for radioactive air particulate and radioiodine monitoring are consistent with past measurements and indicate no trends attributed to plant effluents. All samples for radioiodine yielded no detectable 1-131.

Gamma isotopic measurements yielded no indication of any nuclides attributed to station operation. The results for air particulate/radiojodine samples are consistent with measurements that were made during the pre-operational surveillance program.

Air particulate and radioiodine monitoring results are summarized in Table 1.

3

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4

3.

Waterborne, Surface Water:

The results of radioactivity measurements in surface water samples are consistent with past measurements. Tritium was reported as present in 3 of the 36 surface water samples collected.

These results are consistent with the known subsurface interchange that occurs between the closed cooling canal and its surrounding waters, and the pressure gradients caused by the flow of aquifer subsurface waters in South Florida. The highest reported tritium is less than 11% of the required detection level specified by ODCM Table 5.1-3.

4.

Waterborne, Sediment:

The results are consistent with past measurements. Only cosmic-ray produced Be-7 and naturally occurring isotopes were identified.

5.

Waterborne, Food Products:

The results are consistent with past measurements; only naturally occurring radionuclides were detected.

6.

Broad Leaf Vegetation The results of radioactivity measurements are consistent with past measurements. Cs-1 37 was detected, as in the past, in samples collected from the indicator and control locations. The maximum concentration reported was less than 11% of the reporting level specified by ODCM Table 5.1-2. No other fission products were detected.

7.

Land Use Census No locations yielding a calculated dose or dose commitment greater than the values currently being calculated were identified by the land use census.

Note that the bearing changed for virtually all locations, the range changed slightly for some. The locations have not changed, just their range and bearing relative to the plant. This is the result of using a GPS, polar north as datum, to refine the locations determined from maps & use of a compass (magnetic north).

No locations yielding a calculated dose or dose commitment (via the same exposure pathway) 20% greater than locations currently being sampled in the radiological environmental monitoring program were identified by the land use census.

4

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4

8.

Interlaboratory Comparison Program For those nuclides associated with nuclear power plant operation and using analytical methods used in the REMP, the results are listed in Attachment C.

The Air Filter matrix results for QAP-56 included "Warning" and "Not Acceptable"; laboratory results specifically for Co-60 and Mn-54 were high, above the limits. Both Cs-137 and Gross Beta analysis for the same specimen were Acceptable. The laboratory technician performing the analysis entered an incorrect 'sample collection date'; causing an overcompensation for radioactive decay.

Upon discovery of the problem and cause, the results were recalculated. The corrected results are within the Acceptable range.

The Vegetation matrix results for QAP-56 were all "Not Acceptable"; the laboratory results were low by an order of magnitude. The laboratory technician performing the analysis entered a 'typical sample mass' rather than the actual sample mass which happened to be one-tenth of a typical sample mass; causing an underestimation of activity concentration.

Upon discovery of the problem and cause, the results were recalculated. The corrected results are within the Acceptable range.

The laboratory has enhanced the Laboratory Instruction to include additional details concerning the review of the data used for calculating the results.

Data for AC228, AM241, B1212, B1214, Bq U, PB212, PB214 are not included because these radionuclides are not required under the Radiological Environmental Monitoring Program.

C.

Conclusions The data obtained through the Turkey Point Plant Radiological Environmental Monitoring Program verifies that the levels of radiation and concentrations of radioactive materials in environmental samples, representing the highest potential exposure pathways to members of the public, are not being increased.

Additionally, supplemental to the ODCM program, sampling of the direct exposure, inhalation, and ingestion pathways, performed by DOH, does not show adverse trends in levels of radiation and radioactive materials in unrestricted areas.

The measurements verify that the dose or dose commitment to members of the public, due to operation of Turkey Point Units 3 & 4, during the surveillance year, are well within "as low as reasonably achievable (ALARA)" criteria established by 10 CFR 50, Appendix I.

5

Page 1 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL

SUMMARY

Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade, Florida

, Reporting Period Januar 1 - December 31, 2002 (County, State)

PATHWAY: DIRECT RADIATION SAMPLES COLLECTED: TLD UNITS: micro-R/hr Location with Highest Annual Mean Namec Mean (f)

Type and Total Number Lower Limit of All Indicator Distance &

Range Control Locations of Analyses Performed Detectiona (LLD)

Locations Direction Mean (f)b Range Mean (f) Range Exposure Rate, 87d 5.5 (83/83) 4.1 -8.2 Number of Non-routine Reported Measurements = 0 NW-10 10 mi., NW 7.8 (4/4) 7.2 - 8.2 6.1 (4/4) 5.9 -

6.6 TABLE 1

Page 2 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL

SUMMARY

Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade, Florida

, Reporting Period Januar 1 - December 31, 2002 (County, State)

PATHWAY: AIRBORNE SAMPLES COLLECTED:

UNITS: pCirm3 RADIOIODINE AND PARTICULATES Location with Highest Annual Mean Namec Mean (f)b Type and Total Number Lower Limit of All Indicator Distance &

Range Control Locations of Analyses Performed Detectiona (LLD)

Locations Direction Mean (f)b Range Mean (f) Range 31I, 265 0.024

<MDA

<MDA Gross Beta, 265 0.0025 0.014 (210/211) 0.004 - 0.027 T-57 4 mi., NW 0.015 (52/52) 0.007 - 0.026 0.015 (53/53) 0.007 - 0.028 Composite Gamma Isotopic, 20 7Be 0.0052 0.1334 (16/16) 0.0963 - 0.1803 T-72

<1 mi., WSW 0.1407 (4/4) 0.1147 - 0.1803 0.1415 (4/4) 0.1185 - 0.1639

<MDA

<MDA 0.0192 (7/16) 0.0091 - 0.0300

<MDA

<MDA T-72

<1 mi., WSW 0.0211 (2/4) 0.0122 - 0.0299 0.0141 (2/4) 0.0120 - 0.0162 Number of Non-routine Reported Measurements = 0 134Cs 137Cs 2 10Pb 0.00069 0.00066 TABLE 1

Page 3 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL

SUMMARY

Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade, Florida

, Reporting Period January 1 - December 31. 2002 (County, State)

PATHWAY: WATERBORNE SAMPLES COLLECTED: SURFACE WATER UNITS: pCVL Location with Highest Annual Mean Namec Mean (f)b Type and Total Number of Analyses Performed Tritium, 36 Lower Limit of Detectiona (LLD) 230 All Indicator Locations Mean (f) Range 227 (3/24) 160 - 310 Distance &

Direction T-81 6 mi., S Range Control Locations Mean (f)b Range 227 (3/12) 160 - 310

<MDA Gamma Isotopic, 36 40K r`Mn 59Fe 5 8co loco 65Zn 95Zr-Nb 1311 134cs 140 Ba-La 60 4

8 4

4 8

7 5

5 5

11 294 (24/24) 175 - 384

<MDA

<MDA

<MDA T-81 6mi.,S 308 (12/12) 205 - 384 216 (12/12) 64 - 381

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA Number of Non-routine Reported Measurements = 0 TABLE 1

Page 4 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL

SUMMARY

Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade, Florida

, Reporting Period JanuarY 1 - December 31, 2002 (County, State)

PATHWAY: WATERBORNE SAMPLES COLLECTED: SHORELINE SEDIMENT UNITS: pCi/kg, DRY Location with Highest Annual Mean Namec Mean (f)b Type and Total Number of Lower Limit of All Indicator Distance & Direction Range Control Locations Analyses Performed Detectiona (LLD)

Locations Mean (f)b Range Mean (f) Range Gamma Isotopic, 6 7Be 100 140 210Pb 226Ra 232Th 235u 238u 49 9

5 8 co 6oCO 134Cs 1 3 7cs 12 14 12 417 (4/4) 206 - 621 358 (4/4) 244 - 517 1003 (1/4) 677 (4/4) 450 - 956 116 (1/2) 46 (2/2) 34 - 57 593 (3/4) 523 - 634 T-81 6 mi.,S T-81 6mi.,S T-81 6mi.,S T-42

<1 mi., ENE T-81 6mi.,S T-81 6mi.,S T-81 6mi.,S 546 (212) 470 - 621 450 (2/2) 383 - 517 1003 (1/2) 720 (2/2) 85 - 956 116 (1/2) 57 (1/2) 628 (2/2) 621 - 634

<MDA

<MDA

<MDA

<MDA

< MDA 126 (2/2) 122-130

<MDA 76 (212) 60 - 93

< MDA

< MDA 200 (1/2)

<MDA

<MDA

<MDA

<MDA Number of Non-routine Reported Measurements = 0 TABLE 1

Page 5 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL

SUMMARY

Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade, Florida

, Reporting Period January 1 - December 31. 2002 (County, State)

PATHWAY: INGESTION SAMPLES COLLECTED:

UNITS: pCVkg, WET CRUSTACEA Location with Highest Annual Mean Namec Mean (f)b Type and Total Number of Analyses Performed Lower Limit of Detectiona (LLD)

All Indicator Locations Mean (f) Range Distance &

Direction Range Control Locations Mean (f)b Range Gamma Isotopic, 4 1854 (2/2) 1707 - 2001 816 (2/2) 714 - 918 T-81 6 mi., S T-81 6 mi., S 1854 (2/2) 1707 - 2001 816 (2/2) 714-918

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA 1822 (2/2) 1803 - 1840

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA Number of Non-routine Reported Measurements = 0 226Ra 130 20 mRa 54Mn 59Fe 58co 6oCO 65Zn 134cs 13 7 Cs 9

16 9

19 17 9

9 TABLE 1

Page 6 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL

SUMMARY

Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade, Florida

, Reporting Period January 1 - December 31, 2002 (County, State)

PATHWAY: INGESTION SAMPLES COLLECTED: FISH UNITS: pCiVkg, WET Location with Highest Annual Mean Namec Mean (f)b Type and Total Number of Analyses Performed Lower Limit of Detectiona (LLD)

All Indicator Locations Mean (f) Range Distance &

Direction Range Control Locations Mean (f)b Range Gamma Isotopic, 4 7Be 2736 (2/2) 2263 - 3208 T-81 6 mi., S 2736 (2/2) 2263 - 3208

<MDA 3608 (2/2) 2716 - 3421

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

< MDA)

<MDA Number of Non-routine Reported Measurements = 0 130

<MDA 9

5Mn 59Fe 58co 6oCO 65Zn 134Cs

'37Cs 2 6 Ra

<MDA 16 9

10 17 9

9 20 TABLE 1

Page 7 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL

SUMMARY

Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade. Florida

, Reporting Period JanuarY 1 - December 31. 2002 (County, State)

PATHWAY: INGESTION SAMPLES COLLECTED:

UNITS:

Ci/ka. WET BROAD LEAF VEGETATION Location with Highest Annual Mean Namec Mean (f)b Type and Total Number Lower Limit of All Indicator Distance &

Range Control Locations of Analyses Performed Detectiona (LLD)

Locations Direction Mean (f)b Range Mean (f)Range Gamma Isotopic, 36 1498 (24/24) 596 -3233 722 (24/24) 1745 - 7035 T-40 3mi.,W T-41 2 mi., W/NW 1572 (12/12) 596 - 3233 4531 (12/12) 2669 - 7035

<MDA 1306 (12/12) 490 - 1851 4179 (12/12) 2291 - 5922

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA T-41 2 mi., W/NW T-40 3mi.,W T-40 3mi.,W Number of Non routine Reported Measurements = 0 7Be 71 100 5,co

'Go 1311 9

10 9

8 137Cs 8

210Pb mRa 78 (23/24) 22 - 208 579 (3/24) 296 - 749 200 (1/24) 78 (11/12) 22 - 208 683 (1/12) 200 (1/12) 46 (1/12) 545 (1/12)

< MDA TABLE 1

Page 8 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL

SUMMARY

Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade, Florida

, Reporting Period January 1 - December 31, 2002 (County, State)

NOTES

a.

The LLD is an "a priori" lower limit of detection which establishes the smallest concentration of radioactive material in a sample that will yield a net count above system background that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a real signal.

LLDs in this column are at time of measurement. The MDAs reported in Attachment B for the individual samples have been corrected to the time of sample collection.

b.

Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f).

c.

Specific identifying information for each sample location is provided in Attachment A.

d.

Results were based upon the average net response of three elements in a TLD. (Thermoluminescent Dosimeter).

MDA refers to minimum detectable activity.

TABLE 1

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 TABLE 1A

{Page 1 of 2)

DEVIATIONS / MISSING DATA A)

Pathway:

Location:

Dates:

Deviation:

Description of Problem:

Corrective Action:

B)

Pathway:

Location:

Dates:

Deviation:

Description of Problem:

Corrective Action:

C)

Pathway:

Location:

Dates:

Deviation:

Description of Problem:

Corrective Action:

Airborne, Radioiodines & Particulates T-57, 4 miles NorthWest 02/05/03 to 02/14/03 Failure to provide continuous monitoring.

Vacuum hose found disconnected from air sampling system; unknown cause.

Reconnected hose, ensured good fit; checked connections at other air sampling locations.

Airborne, Radioiodines & Particulates T-51, 2 miles, NorthNorthWest 05/06/03 to 05/13/03 Failure to provide continuous monitoring.

Partial sample collected; sampling station damaged by gunfire Repaired sampling station 'hut'; replaced sampling station equipment, ensured equipment operating correctly.

Airborne, Radioiodines & Particulates T-72, < 1 mile WestSouthWest 06/03/03 to 06/12/03 Failure to provide continuous monitoring.

Partial sample collected; suspect power interruptions during sampling period.

Ensured equipment operating correctly.

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 TABLE 1A

{Page 2 of 2)

DEVIATIONS / MISSING DATA D)

Pathway:

Location:

Dates:

Deviation:

Description of Problem:

Corrective Action:

E)

Pathway:

Location:

Dates:

Deviation:

Description of Problem:

Corrective Action:

Airborne, Radioiodines & Particulates T-72, < 1 mile WestSouthWest 08/28/03 to 09/12/03, two sampling periods Failure to provide continuous monitoring.

Power was unavailable during the end of the first sampling period and beginning of second sampling period; cause was construction activities and temporary shutdown of power.

Ensured equipment operating correctly.

Direct Exposure WSW-8, 8 miles WestSouthWest Fourth calendar quarter Failure to provide continuous monitoring.

TLDs missing when collection was attempted.

Replaced missing TLD.

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 TABLE 1 B ANALYSIS WITH LLDs ABOVE ODCM TABLE 5.1-3 DETECTION CAPABILITIES 1/1/2002-12/31/2002 The values specified in ODCM Table 5.1-3, Detection Capabilities, were achieved for all samples.

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 TABLE 2 LAND USE CENSUS Distance to Nearest (a. b) 6/02 Milk (c) Animal L (e) 0 (f) 0 0

0 0

0 0

L L

L L

L L

L 6/02 Residence (g) 2.0/354 0

0 0

0 0

0 0

L L

L L

L 3.7/302 3.7/311 L

4.4/333 Sector 6/02 Garden (d)

L 0

N NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW 0

0 0

0 0

0 L

L L

L L

4.5/303 4.2/323 4.6 327 NNW

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 TABLE 2 LAND USE CENSUS NOTES

a.

All categories surveyed out to 5 miles radius from the Turkey Point Plant.

b.

The following format is used to denote the location:

distance (miles)/bearing (degrees)

For example, a residence located in the north sector at a distance of 2.1 miles bearing 354 degrees is recorded as 2.1/354.

c.

Potential milk animal locations.

d.

Gardens with an estimated growing area of 500 square feet or more.

e.

L denotes that the sector area is predominantly a land area unoccupied by the category type.

f.

0 denotes that the sector area is predominantly an ocean area.

g.

Non-residential occupied buildings in these sectors include the following:

Sector Distance Description N

1.9/349 24-hour Security Staff Building NNW 1.9/349 Security booth at park entrance

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 ATTACHMENT A KEY TO SAMPLE LOCATIONS

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 NEAR SITE SAMPLING LOCATIONS M~4 licida CitX

.-i 1~ ~

I',-..

t.e,
t.

)

,,.1 5

> t

., - i -

NI\\WNN-21 BIS::CANE"

_ ~ ~ ~......

I~~~~~~~~~~~~~~~~~~~~~~~~~~~~

T t

..6....

...4....

~\\

T8

 I --11 "I I I1, ...

-111 F;

,.,I..,I, -,.1-..

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 DISTANT REMP SAMPLING LOCATIONS C uf.e.

B~.

N~~~~~~~~~~~~-1

~

~

~

~

~

~

an s I ~ e 1QV

~~~HomesteadT 57

~

~

T-w-s T-40

.~~~~~~~.......all Old.Rh.de ey Turtle H.............

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 ArrACHMENT A PAGE 1 OF 4 PATHWAY: DIRECT RADIATION SAMPLES COLLECTED: TLD SAMPLE COLLECTION FREQUENCY: QUARTERLY Location (a)

Name Description N-2 Convey Point, Parking Area N-7 Black Point Marina Parking Lot N-1 0 Old Cutler Rd. approx. 196th Street NNW-2 East End North Canal Road NNW-10 Bailes Road & U.S. #1 NW-1 Turkey Point Entrance Road NW-5 Mowry Drive & 11 7th Avenue NW-10 Newton Road, North of Coconut Palm Drive WNW-10 Homestead Middle School W-1 On-Site, North Side of Discharge Canal W-5 Palm Drive & Tallahassee Road W-9 Card Sound Road, 0.6 mile from U.S. #1 WSW-8 Card Sound Road, 3.4 miles from U.S. #1 SW-i On-Site near Land Utilization Offices SW-8 Card Sound Road, 5 miles from U.S. #1 SSW-5 On-Site, Southwest Corner of Cooling Canals SSW-l0 Card Sound Road, west side of Toll Plaza S-5 On-Site, South East Corner of Cooling Canals S-10 Card Sound Road at Steamboat Creek SSE-1 Turtle Point SSE-10 Ocean Reef Control NNE-22 Natoma Substation aThe location name is the direction sector - approximate distance (miles)

I

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 ATTACHMENT A Page 2 of 4 PATHWAY: AIRBORNE SAMPLES COLLECTED: RADIOIODINE AND PARTICULATES SAMPLE COLLECTION FREQUENCY: WEEKLY Direction Sector NNW NW NW WSW Approximate Distance (miles) 2 4

1

<1 Description Entrance Area to Biscayne National Park SW 107th Avenue at Mowry Canal Turkey Point Entrance Road Just before entrance to Land Utilization's access gate.

Control:

T-64 NNE 22 Natoma Substation Location Name T-51 T-57 T-58 T-72

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 ATTACHMENT A Page 3 of 4 PATHWAY: WATERBORNE SAMPLES COLLECTED: SURFACE WATER (OCEAN)

SAMPLE COLLECTION FREQUENCY: MONTHLY Location Name T-42 Direction Sector ENE Approximate Distance (miles)

<1 S

Control:

T-67 6

N, NNE 13-18 Description Biscayne Bay at Turkey Point Card Sound, near Mouth of Old Discharge Canal Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park SAMPLES COLLECTED: SHORELINE SEDIMENT SAMPLE COLLECTION FREQUENCY: SEMI-ANNUALLY Approximate Distance (miles)

<1 6

13-18 Description Biscayne Bay at Turkey Point Card Sound, near Mouth of Old Discharge Canal Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park T-81 Location Name Direction Sector T-42 ENE T-81 S

Control:

T-67 N, NNE

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 ATTACHMENT A Page 4 of 4 PATHWAY: INGESTION SAMPLES COLLECTED: CRUSTACEA AND FISH SAMPLE COLLECTION FREQUENCY: SEMI-ANNUALLY Approximate Distance (miles) 6 13-18 Description Card Sound Vicinity of Turkey Point Facility Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park SAMPLES COLLECTED: BROAD LEAF VEGETATION SAMPLE COLLECTION FREQUENCY: MONTHLY Approximate Distance (miles) 3 2

13-18 Description South of Palm Dr. on S.W. 11 7th Street Extension Palm Dr., West of Old Missile Site near Plant Site Boundary Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Location Name Direction Sector T-81 S

Control:

T-67 N, NNE Location Name T-40 T-41 Control:

T-67 Direction Sector W

WNW N, NNE

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 ATTACHMENT B RADIOLOGICAL SURVEILLANCE OF FLORIDA POWER AND LIGHT COMPANY'S TURKEY POINT SITE 2002 First Quarter, 2002 Second Quarter, 2002 Third Quarter, 2002 Fourth Quarter, 2002

TP QR02-1 TURKEY POINT SITE Offsite Dose Calculation Manual Sampling First Quarter, 2002 Sample Type

1. Direct Radiation
2. Airborne 2.a. Air Iodines 2.b. Air Particulates
3. Waterborne 3.a. Surface Water 3.b. Shoreline Sediment
4. Ingestion 4.a. Fish and Invertebrates 4.a.1. Crustacea 4.a.2. Fish 4.b. Broadleaf Vegetation Collection Frequency Quarterly Weekly Weekly Monthly Semiannually Semiannually Semiannually Monthly NOTE Measurement results having magnitudes that are significantly above the background of the measurement system are reported as net values plus or minus a one-standard-deviation error term.

Measurement results that are not significantly above background are reported as less than a Lower Limit of Detection (<LLD), which is an estimated upper limit (with at least 95% confidence) for the true activity in the sample.

1 of 7 Locations Sampled 22 5

5 3

3 2

Number of Samples 22 64 64 9

3 2

2 3

2 9

Total: 175

TP QR02-1

1. DIRECT RADIATION - TLDs - (Rhour)

Deployment 05-ec 01 Collection 20-Mar-02 5.7 +/- 0.2 5.0 +/- 0.2 5.1 +/-0.2 4.8+/-0.2 6.2 +/- 0.2 7.0 +/- 0.3 4.7 +/- 0.2 8.0 +/- 0.3 6.7 +/- 0.3 7.0 +/- 0.3 5.2 +/- 0.2 5.1 +/-0.2 Sample Site WSW-8 Sw-i SW-8 SSW-5 SSW-lo S-5 S-10 SSE-1 SSE-10 NNE-22 Deployment 05-ec 01 Collection 20-Mar-02 5.0 +/- 0.2 5.0 +/- 0.2 5.6 +/- 0.2 4.9 +/- 0.2 5.2 +/- 0.2 4.7 +/- 0.2 5.7 +/- 0.2 4.8 +/- 0.2 5.8 +/-0.2 5.9 + 0.2 2 of 7 Sample Site N-2 N-7 N-10 NNW-2 NNW-10 NW-1 NW-5 NW-10 WNW-10 W-1 W-5 W-9

TP QR02-1 2.a. IODINE-131 IN WEEKLY AIR CARTRIDGES - (pCi/m3)

Collection Date 02-Jan-02 07-Jan-02 14-Jan-02 24-Jan-02 28-Jan-02 05-Feb-02 14-Feb-02 19-Feb-02 26-Feb-02 05-Mar-02 11-Mar-02 18-Mar-02 26-Mar-02 T51

<0.05

<0.03

<0.03

<0.02

<0.06

<0.02

<0.02

<0.03

<0.02

<0.03

<0.04

<0.02

<0.03 T57

<0.06

<0.03

<0.03

<0.02

<0.06

<0.02 (A)

<0.03

<0.02

<0.03

<0.04

<0.02

<0.03 T58

<0.05

<0.03

<0.03

<0.02

<0.05

<0.02

<0.02

<0.03

<0.02

<0.03

<0.04

<0.02

<0.03 T64

<0.06

<0.03

<0.03

<0.02

<0.06

<0.02

<0.02

<0.03

<0.02

<0.03

<0.04

<0.02

<0.03 T72

<0.05

<0.03

<0.03

<0.02

<0.05

<0.02

<0.02

<0.03

<0.02

<0.03

<0.04

<0.02

<0.03 (A) No sample was collected due to a disconnected hose.

3 of 7

TP QR02-1 2.b.1. AR PARTICULATES - GROSS BETA - (pCi/m3)

Sample site Collection Date T51 02-Jan-02 0.027 +/- 0.003 07-Jan-02 0.017 +/- 0.003 14-Jan-02 0.015 +/- 0.002 24-Jan-02 0.010 +/- 0.001 28-Jan-02 0.007 +/- 0.002 05-Feb-02 0.012 +/- 0.002 14-Feb-02 0.017 +/- 0.002 19-Feb-02 0.017 +/- 0.003 26-Feb-02 0.020 +/- 0.002 05-Mar-02 0.021 +/- 0.002 11-Mar-02 0.010 +/- 0.002 18-Mar-02 0.016 +/- 0.002 26-Mar-02 0.017 +/- 0.002 Mean:

0.016 +/- 0.001 T57 0.024 +/- 0.003 0.015 +/- 0.003 0.021 +/- 0.003 0.011 +/- 0.002 0.007 +/- 0.003 0.008 +/- 0.002 (A) 0.018 +/- 0.003 0.018 +/- 0.002 0.021 +/- 0.002 0.008 +/- 0.002 0.018 +/- 0.002 0.020 +/- 0.002 0.016 +/- 0.001 T58 0.017 +/- 0.003 0.015 +/- 0.003 0.017 +/- 0.002 0.012 +/- 0.002 0.011 +/- 0.003 0.010 +/- 0.002 0.016 +/- 0.002 0.027 +/- 0.003 0.018 +/- 0.002 0.020 +/- 0.002 0.010 +/- 0.002 0.014 +/- 0.002 0.015 +/- 0.002 0.016 +/- 0.001 T64 0.018 +/- 0.003 0.019 +/- 0.003 0.018 +/- 0.002 0.011 +/- 0.002 0.009 +/- 0.003 0.011 +/- 0.002 0.020 +/- 0.002 0.019 +/- 0.003 0.019 +/- 0.002 0.022 +/- 0.002 0.009 +/- 0.002 0.016 +/- 0.002 0.018 +/- 0.002 0.016 +/- 0.001 T72 0.022 +/- 0.003 0.013 +/- 0.003 0.020 +/- 0.002 0.009 +/- 0.001 0.009 +/- 0.003 0.011 +/- 0.002 0.017 +/- 0.002 0.018 +/- 0.003 0.020 +/- 0.002 0.023 +/- 0.002 0.012 +/- 0.002 0.016 +/- 0.002 0.018 +/- 0.002 0.016 +/- 0.001 (A) No sample was collected due to a disconnected hose.

2.b.2. AIR PARTICULATES GAMMA ANALYSIS OF QUARTERLY COMPOSITES (pCi/m3)

Be-7 0.1577 +/- 0.0133 0.1783 +/- 0.0130 0.1610 +/- 0.0164 0.1639 +/- 0.0126 0.1803 +/- 0.0134 K-40 Cs-134

<0.0294

<0.0013

<0.0225

<0.0014

<0.0286

<0.0017

<0.0183

<0.0011

<0.0187

<0.0012 Cs-137

<0.0012

<0.0010

<0.0014

<0.0012

<0.0008 Pb-210

<0.0459 0.0300 +/- 0.0037

<0.0459 0.0162 +/- 0.0039 0.0299 +/- 0.0041 4 of 7 Sample Site T51 T57 T58 T64 T72

TP QR02-1 3.a. SURFACE WATER - (pCi/L)

Sample Site T42 T67 T81 Collection Date 25-Jan-02 07-Feb-02 19-Mar-02 26-Jan-02 07-Feb-02 19-Mar-02 22-Jan-02 08-Feb-02 19-Mar-02 H-3

<120

<1 19

<122

<1 19

<1 19

<122

<121 160 +/- 23

<122 K-40 248 +/- 21 271 +/- 46 286 +/- 42 236 +/- 43 111 +/- 26 64+/-31 343 +/- 33 276 +/- 40 293 +/- 38 Mn-54

<2

<4

<6

<5

<3

<4

<3

<6

<4 Co-58

<2

<5

<5

<5

<5

<5

<4

<5

<4 Fe-59

<5

<13

<10

<10

<13

<12

<9

<11

<9 Co-60

<2

<6

<5

<5

<4

<3

<4

<7

<4 Zn-65

<5

<12

<11

<12

<6

<14

<9

<14

<8 Zr-95 Nb-95 (A)

<4

<13

<11

<11

<9

<11

<7

<11

<6 I-131

<4

<14

<8

<11

<35

<9

<12

<14

<7 Cs-134

<3

<6

<6

<6

<5

<5

<4

<6

<3 Cs-137

<2

<7

<6

<6

<4

<6

<4

<7

<4 Ba-140 La-140 (B)

<4

<10

<8

<10

<9

<7

<6

<7

<6 (A) These tabulated LLD values for Zr/Nb-95 are the higher of the individual parent or daughter LLDs.

(B) These tabulated LLD values are for Ba-140, either based on direct measurement of Ba-140 or based on ingrowth of La-140, whichever method yields the greater sensitivity for a given sample.

5 of 7

TP QR02-1 3.b. SHORELINE SEDIMENT - (pCi/kg, dry weight)

Sample Site T42 T67 T81 Collection Date 25-Jan-02 26-Jan-02 22-Jan-02 Be-7 206 +/- 42

<41 470 +/- 35 K-40 244 +/-53 122 +/- 28 383 +/- 47 Co-58

<10

<4

<6 Co-60

<8

<4

<6 Cs-134

<11

<4

<7 Cs-137

<10

<5 Pb-210

<1910

<1642 Ra-226 485 +/- 116 60+/-10

<6 1003 +/- 128 815 +/- 10 Th-232

<39

<24 116 +/- 11 U-238

<540

<581 634 +/- 86 4.a.1. CRUSTACEA - Blue Crab, (Ci/fk%,

wet weight)

Sample Site T67 T81 Collection Date 26-Feb-02 19-Feb-02 K-40 1803 +/- 184 2001 +/- 237 Mn-54

<22

<37 Co-58

<23

<44 Fe-59

<73

<85 Co-60

<17

<42 Zn-65

<41

<63 Cs-134

<25

<31 Cs-137

<22

<40 Ra-226

<432 714 +/- 342 4.a.2. FISH - Red Snapper, Mangrove Snapper - (pCi/kg. wet weight)

Fe-59 Co-60 Zn-65 Cs-134 Cs-137

<97

<35

<87

<28

<37

<103

<37

<54

<35

<38 6 of 7 Sample Site T67 T81 Collection Date 28-Feb-02 18-Feb-02 K-40 3421 +/- 272 3208 +/- 337 Mn-54

<28

<30 Co-58

<41

<41 Ra-226

<618

<599 Ra-228

<84

<115

TP QR02-1 4.b. BROADLEAF VEGETATION - Brazilian Pepper - (pCi/lkg. wet weight)

Sample Collection Site Date Be-7 K-40 1-131 Cs-134 Cs-137 Pb-210 Ra-226 T40 25-Jan-02 1569 113 2961 +/- 212

<26

<22 72 +/- 11

<2179

<429 08-Feb-02 1559 93 4268 +/- 171

<35

<12 84 +/- 10

<927

<349 19-Mar-02 1857 107 2821 +/- 165

<23

<17 104 9

<1121

<402 T41 25-Jan-02 1907+/-55 4597+/- 111

<14

<10 66+/-5

<931

<193 08-Feb-02 1446 106 4235 +/- 175

<36

<11 85 9

<1070

<328 19-Mar-02 1220 79 7035 +/- 213

<20

<14 26 6

<841

<313 T67 26-Jan-02 490 65 5302 +/- 216

<23

<15

<16

<1007

<364 07-Feb-02 672+/- 119 2842+/- 151

<43

<17

<15

<1075

<386 19-Mar-02 1567 +/- 85 5342 +/- 186

<20

<14

<12

<883

<294 7 of 7.

TP QR02-2 TURKEY POINT SITE Offsite Dose Calculation Manual Sampling Second Quarter, 2002 Sample Type

1. Direct Radiation Collection Frequency Quarterly
2. Airborne 2.a. Air lodines 2.b. Air Particulates
3. Waterborne 3.a. Surface Water Weekly Weekly Monthly Locations Sampled 22 5

5 3

3.b. Shoreline Sediment

4. Ingestion 4.a. Fish and Invertebrates 4.a.1. Crustacea 4.a.2. Fish 4.b. Broadleaf Vegetation Semiannually Semiannually Semiannually Monthly Total: 170 NOTE: Measurement results having magnitudes that are significantly above the background of the measurement system are reported as net values plus or minus a one-standard-deviation error term.

Measurement results that are not significantly above background are reported as less than a Lower Limit of Detection (<LLD), which is an estimated upper limit (with at least 95% confidence) for the true activity in the sample.

1 of 6 Number of Samples 22 65 65 9

0 0

0 0

0 3

0 9

TP QR02-2

1. DIRECT RADIATION - TLDs - (iR/hour)

Sample Deployment 20-Mar-02 Sample Deployment 20-Mar-02 Site Collection 13-Jun-02 Site Collection 13-Jun-02 N-2 5.8 +/- 0.2 W-9 4.3 + 0.2 (A)

N-7 4.9 +/- 0.2 WSW-8 5.0 + 0.2 (A)

N-10 5.0 +/- 0.2 SW-i 5.1 +/- 0.2 NNW-2 4.5 +/- 0.2 SW-8 5.2 +/- 0.2 NNW-10 5.6 +/- 0.2 SSW-5 4.8 +/- 0.2 NW-1 6.4 +/- 0.2 SSW-lo 4.9 +/- 0.2 NW-5 4.7 +/- 0.2 S-5 4.6 +/- 0.2 NW-10 7.6 +/- 0.3 S-10 5.4 +/- 0.2 WNW-10 6.0 +/- 0.2 SSE-1 4.5 +/- 0.2 W-1 6.6 +/- 0.3 SSE-10 5.6 +/- 0.2 W-5 5.6 +/- 0.2 NNE-22 5.9 +/- 0.2 (A) The TLDs at site W-9 and WSW-8 were found on the ground at the collection time 2 of 6

TP QR02-2 2.a. IODINE-131 IN WEEKLY AIR CARTRIDGES - (pCi/m3)

Collection Date T51 T57 T58 T64 T72 01-Apr-02

<0.03

<0.03

<0.02

<0.03

<0.03 08-Apr-02

<0.02

<0.02

<0.02

<0.02

<0.02 18-Apr-02

<0.02

<0.02

<0.02

<0.02

<0.02 23-Apr-02

<0.04

<0.04

<0.04

<0.04

<0.04 02-May-02

<0.02

<0.02

<0.02

<0.02

<0.02 06-May-02

<0.03

<0.04

<0.04

<0.04

<0.04 13-May-02

<0.04 (A)

<0.02

<0.02

<0.02

<0.02 20-May-02

<0.02

<0.02

<0.02

<0.02

<0.02 28-May-02

<0.01

<0.01

<0.01

<0.01

<0.01 03-Jun-02

<0.02

<0.02

<0.02

<0.02

<0.02 12-Jun-02

<0.01

<0.01

<0.01

<0.01

<0.01 (B) 17-Jun-02

<0.03

<0.03

<0.03

<0.02

<0.03 26-Jun-02

<0.02

<0.02

<0.02

<0.02

<0.02 (A)

A partial sample was collected at site T51 due to the sampling box, gas meter and pump being shot with 22 caliber bullets. The vacuum of the system was lost when the gas meter was punctured by multiple bullets.

We estimate the run time before the incident at 87.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. Based on this, the incident happened about 0017 hours1.967593e-4 days <br />0.00472 hours <br />2.810847e-5 weeks <br />6.4685e-6 months <br /> on May 10. A new gasmeter was deployed and the holes in the sampling box were patched with a metal plate.

(B) A partial sample was collected at site T72 due to a power interruption of unknown cause. The run time was estimated at 195.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> out of a sampling period of 211.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br />.

3 of 6

TP QR02-2 2.b.1. AIR PARTICULATES - GROSS BETA - (pCi/m3 )

Sample Site T51 0.015 i 0.002 0.019 + 0.002 0.013 i 0.002 0.009 +/- 0.002 0.017 i 0.002 0.014 i 0.003 0.025 i 0.004 A) 0.015 +/- 0.002 0.008 +/- 0.002 0.011 + 0.002 0.014 + 0.002 0.010 i 0.002 0.009 + 0.002 0.014 i 0.001 T57 0.018 i 0.002 0.020 + 0.002 0.013 i 0.002 0.011 +/- 0.003 0.017 i 0.002 0.019 i 0.003 0.017 i 0.002 0.010 i 0.002 0.008 i 0.002 0.011 + 0.002 0.013 i 0.002 0.009 i 0.002 0.012 +/- 0.002 0.014 + 0.001 T58 0.013 i 0.002 0.015 + 0.002 0.012 i 0.001 0.009 i 0.002 0.017 +/- 0.002 0.014 i 0.003 0.017 i 0.002 0.013 +/- 0.002 0.006 +/- 0.001 0.013 i 0.002 0.017 i 0.002 0.007 +/- 0.002 0.010 +/- 0.002 0.012 +/- 0.001 T64 0.013 +/- 0.002 0.018 +/- 0.002 0.014 +/- 0.002 0.011 +/- 0.003 0.018 +/- 0.002 0.025 +/- 0.003 0.019 +/- 0.002 0.010 +/- 0.002 0.012 +/- 0.002 0.011 +/- 0.002 0.013 +/- 0.002 0.008 +/- 0.002 0.010 +/- 0.002 0.014 +/- 0.001 T72 0.014 +/- 0.002 0.016 +/- 0.002 0.013 +/- 0.002 0.010 +/- 0.003 0.015 +/- 0.002 0.020 +/- 0.003 0.016 +/- 0.002 0.012 +/- 0.002 0.007 i 0.002 0.011 i0.002 0.014 +/- 0.002(B) 0.010 +/- 0.002 0.013 +/- 0.002 0.013 +/- 0.001 (A) A partial sample was collected at site T51 due to the sampling box, gas meter and pump being shot with 22 caliber bullets. The vacuum of the system was lost when the gas meter was punctured by multiple bullets.

We estimate the run time before the incident at 87.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. Based on this, the incident happened about 0017 hours1.967593e-4 days <br />0.00472 hours <br />2.810847e-5 weeks <br />6.4685e-6 months <br /> on May 10. A new gas meter was deployed and the holes in the sampling box were patched with a metal plate.

(B)

A partial sample was collected at site T72 due to a power interruption of unknown cause. The run time was estimated at 195.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> out of a sampling period of 211.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br />.

2.b.2. AIR PARTICULATES GAMMA ANALYSIS OF OUARTERLY COMPOSITES pCi/m3)

Be-7 0.1028 + 0.0099 0.1116 +/- 0.0094 0.1508 +/- 0.0152 0.1206 +/- 0.0081 0.1147 +/- 0.0029 K-40

<0.0163

<0.0129

<0.0304

<0.0157

<0.0046 Cs-134

<0.0007

<0.001 1

<0.0021

<0.0003

<0.0003 Cs-137

<0.0010

<0.0007

<0.0016

<0.0007

<0.0002 Pb-210 0.0097 +/- 0.0022 0.0091 +/- 0.0027

<0.0612 0.0120 +/- 0.0024 0.0122 +/- 0.0009 4 of 6 Collection Date 01-Apr-02 08-Apr-02 18-Apr-02 23-Apr-02 02-May-02 06-May-02 13-May-02 20-May-02 28-May-02 03-Jun-02 12-Jun-02 17-Jun-02 26-Jun-02 Mean:

Sample Site T51 T57 T58 T64 T72

TP QR02-2 3.a. SURFACE WATER - (pCi/L)

Sample Collection Site Date T42 04-Apr-02 07-May-02 10-Jun-02 T67 04-Apr-02 10-May-02 10-Jun-02 T81 04-Apr-02 08-May-02 10-Jun-02 H-3

<118

<117

<123

<118

<117

<123

<120

<117

<123 K-40 322 40 326 +/- 46 382 +/- 46 141 +/- 29 381 +/-35 351 +/- 32 331 +/- 32 309 +/- 31 343 +/-46 Mn-54

<5

<5

<6

<6

<3

<3

<3

<5

<6 Co-58

<5

<7

<5

<6

<3

<3

<3

<3

<6 Fe-59

<10

<16

<10

<12

<7

<7

<8

<8

<13 Co-60

<6

<6

<7

<6

<4

<4

<4

<5

<6 Zn-65

<13

<10

<15

<13

<7

<8

<7

<10

<14 Zr-95 Nb-95 (A)

<11

<10

<11

<10

<7

<5

<7

<7

<9 1-131

<10

<12

<9

<10

<7

<7

<7

<8

<9 Ba-140 Cs-134 Cs-137 La-140 (B)

<6

<6

<6

<6

<7

<6

<5

<6

<3

<4

<4

<4

<4

<3

<3

<3

<6

<6

<9

<11

<9

<7

<6

<7

<5

<4

<9 (A)

These tabulated LLD values for Zr/Nb-95 are the higher of the individual parent or daughter LLDs.

(B)

These tabulated LLD values are for Ba-140, either based on direct measurement of Ba-140 or based on ingrowth of La-140, whichever method yields the greater sensitivity for a given sample.

3.b. SHORELINE SEDIMENT - (pCi/kg. dry weight)

Collection Date Be-7 K-40 Co-58 These samples were previously collected.

Co-60 Cs-134 Cs-137 Pb-210 Ra-226 U-238 5 of 6 Sample Site

TP QR02-2 4.a.1. CRUSTACEA - (pCiIkg. wet weinht)

Sample Site Collection Date K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Cs-134 Cs-137 Ra-226 Ra-228 These samples were previously collected.

4.a.2. FISH - (pCi/k, wet weight)

Sample Site Collection Date K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Cs-134 Cs-137 Ra-226 Ra-228 These samples were previously collected.

4.b. BROADLEAF VEGETATION - Brazilian Pepper - (pCi/kg. wet weight)

Sample Site T40 T41 T67 Collection Date 04-Apr-02 09-May-02 10-Jun-02 04-Apr-02 09-May-02 10-Jun-02 04-Apr-02 10-May-02 10-Jun-02 Be-7 2036 +/- 97 596 +/- 56 928 +/- 73 1316 +/- 81 643 +/- 73 902 +/- 32 1832 +/- 85 630 +/- 64 1511 +/- 69 K-40 2417 +/- 128 2659 +/- 133 3232 +/- 131 4688 +/- 166 4956 +/- 230 4965 +/- 84 5922 +/- 206 4968 +/- 172 4403 +/- 160 1-131'

<21

<19

<18

<18

<38

<9

<21

<26

<19 Cs-134

<10

<11

<11

<11

<16

<6

<13

<11

<12 Cs-137 50+/-6 91+/-8 82+/- 8 80+/- 8

<17 22+/-3

<12

<10

<12 Pb-210 683 +/- 275

<620

<635 749 +/- 274

<1939 296 +/- 122

<868

<674

<719 Ra-226

<296

<224

<239

<259

<333

<1 10

<300

<239

<250 6 of 6

TP QR02-3 TURKEY POINT SITE Offsite Dose Calculation Manual Specifications Sampling Third Quarter, 2002 Sample Type

1. Direct Radiation Collection Frequency Quarterly Locations Sampled 22 Number of Samples 22
2. Airborne 2.a. Air lodines 2.b. Air Particulates
3. Waterborne 3.a. Surface Water 3.b. Shoreline Sediment Weekly Weekly Monthly Semiannually
4. Ingestion 4.a.Fish and Invertebrates 4.a.l. Crustacea 4.a.2. Fish 4.b. Broadleaf Vegetation Semiannually Semiannually Monthly NOTE: Measurement results having magnitudes that are significantly above the background of the measurement system are reported as net values plus or minus a one-standard-deviation error term.

Measurement results that are not significantly above background and with greater than a 50% error term are reported as less than a Lower Limit of Detection (<LLD), which is an estimated upper limit (with at least 95% confidence) for the true activity in the sample.

1 of 6 5

65 5

65 3

3 9

3 2

2 3

1 1

9 Total: 175

TP QR02-3

1. DIRECT RADIATION - TLDs - (ttR/hour)

Deployment 13-Jun-02 Collection 18-Sep-02 5.1 +/-0.2 4.3 + 0.2 (A) 4.9 +/-0.2 4.4 +/- 0.2 5.3 +/- 0.2 6.4 +/- 0.2 4.1 +/- 0.2 7.2 +/- 0.3 6.2 +/- 0.2 6.4 +/- 0.2 5.6 +/- 0.2 Sample Site W-9 WSW-8 SW-i SW-8 SSW-S SSW-10 S-S S-10 SSE-1 SSE-10 NNE-22 Deployment 13-Jun-02 Collection 18-Sep-02 4.2 +/- 0.2 4.6 +/- 0.2 4.7 +/- 0.2 5.1 +/-0.2 4.6 +/- 0.2 4.6 +/- 0.2 4.3 +/- 0.2 5.4 +/- 0.2 4.5 +/- 0.2 5.7 +/- 0.2 6.0 +/-0.2 (A) The TLD at site N-7 was exchanged 09/24/02.

2.a. IODINE-131 IN WEEKLY AIR CARTRIDGES - (pCi/m3)

T51

<0.02

<0.02

<0.03

<0.03

<0.05

<0.02

<0.04

<0.03

<0.04

<0.03

<0.03

<0.02

<0.02 T57

<0.02

<0.02

<0.03

<0.03

<0.05

<0.02

<0.04

<0.03

<0.05

<0.03

<0.03

<0.02

<0.03 T58

<0.02

<0.02

<0.03

<0.03

<0.05

<0.02

<0.04

<0.03

<0.04

<0.03

<0.02

<0.02

<0.02 T64

<0.02

<0.02

<0.03

<0.03

<0.05

<0.02

<0.04

<0.03

<0.04

<0.03

<0.03

<0.02

<0.03 T72

<0.02

<0.02

<0.03

<0.03

<0.05

<0.02

<0.04

<0.03

<0.05

<0.03 (A)

<0.03 (B)

<0.02

<0.02 (A)

Power was off to station T72 for an undetermined time at the end of the sampling period.

(B)

Power was off to station T72 at the beginning of the sampling period. The power was off for 59 hours6.828704e-4 days <br />0.0164 hours <br />9.755291e-5 weeks <br />2.24495e-5 months <br /> out of 171.

2 of 6 Sample Site N-2 N-7 N-10 NNW-2 NNW-10 NW-I NW-5 NW-10 WNW-10 W-1 W-S Collection Date 03-Jul-02 12-Jul-02 17-Jul-02 25-Jul-02 31-Jul-02 09-Aug-02 14-Aug-02 22-Aug-02 28-Aug-02 05-Sep-02 12-Sep-02 18-Sep-02 24-Sep-02

TP QR02-3 2.b. 1. AIR PARTICULATES - GROSS BETA - (pCi/m3)

Sample Site T51 0.010 +/- 0.002 0.010 +/- 0.002 0.022 +/- 0.003 0.016 +/- 0.002 0.018 +/- 0.003 0.012 +/- 0.002 0.016 +/- 0.003 0.009 +/-0.002 0.017 +/- 0.002 0.009 +/- 0.002 0.008 +/- 0.002 0.015 +/- 0.002 0.009 +/-0.002 0.013 +/- 0.001 T57 0.011 +0.002 0.011 +/- 0.002 0.014 +/- 0.003 0.015 +/- 0.002 0.016 +/- 0.003 0.015 +/- 0.002 0.010 +/- 0.002 0.013 +/- 0.002 0.020 +/- 0.003 0.010 +/- 0.002 0.007 +/- 0.002 0.015 +/- 0.002 0.010+/- 0.002 0.013 +/- 0.001 T58 0.013 +/- 0.002 0.014 + 0.002 0.015 +/- 0.003 0.017 +/- 0.002 0.014 +/- 0.002 0.013 +/- 0.002 0.011 +/-0.002 0.011 +/-0.002 0.015 +/- 0.002 0.007 +/- 0.001 0.004 +/- 0.001 0.016 +/- 0.002 0.008 +/- 0.002 0.012 +0.001 T64 0.011 + 0.002 0.010 +/- 0.002 0.017 +/- 0.003 0.017 +/- 0.002 0.021 +/-0.003 0.018 +/- 0.002 0.014 +/- 0.002 0.014 +/- 0.002 0.019 +/- 0.003 0.009 +/- 0.002 0.010 +/- 0.002 0.017 +/- 0.002 0.013 +/- 0.002 0.015 +/- 0.0001 T72 0.014 +/- 0.002 0.013 +/- 0.002 0.012 +/- 0.003 0.015 +/- 0.002 0.020 +/-0.003 0.017 +/- 0.002 0.008 +/- 0.002 0.011 +/- 0.002 0.022 +/- 0.003 0.009 +/- 0.002 (A)

<0.008 (B) 0.017 +/- 0.002 0.009 +/- 0.002

<0.013 (A)

Power was off to station T72 for an undetermined time at the end of the sampling period.

(B)

Power was off to station T72 at the beginning of the sampling period. The power was off for 59 hours6.828704e-4 days <br />0.0164 hours <br />9.755291e-5 weeks <br />2.24495e-5 months <br /> out of 171.

2.b.2. AIR PARTICULATES GAMMA ANALYSIS OF OUARTERLY COMPOS1TES (pCilm3)

Sample Site T51 T57 T58 T64 T72 Be-7 0.0970 +/- 0.0119 0.0992 +/- 0.0131 0.0963 +/- 0.0118 0.1185 +/- 0.0128 0.1154 +/- 0.0167 K-40

<0.0249

<0.0297

<0.0317

<0.0270

<0.0334 Cs-134

<0.0018

<0.0014

<0.0016

<0.0018

<0.0018 Cs-137

<0.0013

<0.0008

<0.0009

<0.0015

<0.0020 Pb-210

<0.0574

<0.0639

<0.0592

<0.0612

<0.0605 3 of 6 Collection Date 03-Jul-02 12-Jul-02 17-Jul-02 25-Jul-02 31-Jul-02 09-Aug-02 14-Aug-02 22-Aug-02 28-Aug-02 05-Sep-02 12-Sep-02 18-Sep-02 24-Sep-02 Mean:

TP QR02-3 3.a. SURFACE WATER - (pCi/L)

Sample Collection Zr-95 Ba-140 Site Date H-3 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 (A)

I-131 Cs-134 Cs-137 La-140 (B)

T42 26-Jul-02

<1 17 295 42

<6

<6

<9

<6

<11

<12

<12

<7

<6

<7 23-Aug-02

<127 175 +/- 34

<5

<6

<13

<5

<11

<11

<8

<6

<7

<11 18-Sep-02

<122 182 + 46

<6

<6

<13

<5

<9

<9

<9

<6

<5

<9 T67 26-Jul-02

<117 145 +/- 32

<6

<6

<15

<7

<14

<9

<12

<6

<6

<12 23-Aug-02

<127 228 +/- 20

<2

<2

<5

<2

<6

<5

<4

<3

<2

<4 18-Sep-02

<122 196 +/- 38

<5

<5

<11

<6

<12

<11

<7

<7

<5

<10 T81 26-Jul-02 212 +/- 25 205+/- 38

<6

<5

<14

<7

<10

<9

<9

<7

<7

<9 21-Aug-02 310 +/- 26 345 +/- 50

<4

<6

<13

<6

<13

<11

<9

<6

<4

<8 18-Sep-02

<122 215 39

<7

<6

<11

<6

<13

<10

<9

<7

<7

<5 (A)

These tabulated LLD values for Zr/Nb-95 are the higher of the individual parent or daughter LLDs.

(B)

These tabulated LLD values are for Ba-140, either based on direct measurement of Ba-140 or based on ingrowth of La-140, whichever method yields the greater sensitivity for a given sample.

4 of 6

TP QR02-3 3.b. SHORELINE SEDIMENT - (tpCi/lkg. dry weight)

Sample Site T42 T67 T81 Collection Date 19-Jul-02 26-Jul-02 26-Jul-02 Be-7 369 + 56

<63 621 +47 K-40 287 26 130 + 19 517 + 61 Co-58

<10

<5

<23 Co-60

<5

<3

<19 Cs-134

<5

<3

<22 Cs-137 7+/-2

<3

<21 Pb-210

<650

<665

<1792 Ra-226 956 +/- 83 93 +/- 3 450 +/- 15 U-235 34+/-7

<15 57+/-16 U-238 523 +/- 58 200 +/- 50 621+/- 83 4.a.1. CRUSTACEA - (pCi/kg. wet weight)

Sample Site T67 T81 Collection Date 19-Jul-02 K-40 1840 +/- 195 This sample has not yet been collected.

4.a.2. FISH - (pCi/kg, wet weight)

Sample Collection Site Date K-40 T67 18-Jul-02 2716 +/- 234 T81 This sample has not yet been collected.

Mn-54

<42 Co-58

<47 Fe-59

<1 19 Co-60

<47 Zn-65

<103 Cs-134

<53 Cs-137

<42 Ra-226

<842 Ra-228

<182 Mn-54

<45 Co-58

<49 Fe-59

<120 Co-60

<39 Zn-65

<108 Cs-134

<47 Cs-137

<45 Ra-226

<807 Ra-228

<185 5 of 6

TP QR02-3 4.b. BROADLEAF VEGETATION - Brazilian Pepper - (pCi/kg. wet weight)

Sample Collection Site Date Be-7 K-40 I-131 Cs-134 Cs-137 Pb-210 Ra-226 T40 30-Jul-02 3233 +/- 143 2693 +/- 171

<20

<17 69 14

<2271

<359 23-Aug-02 1333 +/- 106 2156 +/- 158

<20

<12 73 7

<1699

<324 18-Sep-02 2083 +/- 48 2829 +/- 76

<8

<5 79 4

<724 200 +/- 61 T41 30-Jul-02 2346 +/- 54 2669 +/- 88

<8

<7 38 4

<877

<155 23-Aug-02 1945 122 4438 +/-209

<21

<17 69 10

<1937

<331 18-Sep-02 1851 96 3046 +/- 179

<20

<16 208 13

<1792

<284 T67 30-Jul-02 1630 112 5446 +/-242

<19

<19

<14

<2172

<367 23-Aug-02 1568 108 2291 +/- 153

<21

<12 46 +/- 8

<1865

<329 18-Sep-02 1480+/- 105 3221 +/- 178

<21

<20

<14

<1940

<320 6 of 6

TP QR02-4 TURKEY POINT SITE Offsite Dose Calculation Manual Specifications Sampling Fourth Quarter, 2002 Sample Type Collection Frequencv Locations Sampled

1. Direct Radiation
2. Airborne 2.a. Air lodines 2.b. Air Particulates
3. Waterborne 3.a. Surface Water 3.b. Shoreline Sediment
4. Ingestion 4.a. Fish and Invertebrates Semiannually Semiannually 4.a.l. Crustacea 4.a.2. Fish 4.b. Broadleaf Vegetation Semiannually Monthly NOTE: Measurement results having magnitudes that are significantly above the background of the measurement system are reported as net values plus or minus a one-standard-deviation error term.

Measurement results that are not significantly above background and with greater than a 50% error term are reported as less than a Lower Limit of Detection (<LLD), which is an estimated upper limit (with at least 95% confidence) for the true activity in the sample.

1 of 7 Quarterly Number of Samples 22 Weekly 21 Weekly 5

Monthly 70 5

70 3

9 0

0 1

1 1

3 1

9 Total: 181

TP QR02-4

1. DIRECT RADIATION - TLDs - (JR/hour)

Deployment 18-Sep-02 Collection 1 lDec 5.8 +/- 0.2 5.4 +/- 0.2 5.5 +/- 0.2 5.0 +/- 0.2 6.3 +/- 0.2 7.1 +/- 0.3 4.8 +/- 0.2 8.2 +/- 0.3 7.3 +/- 0.3 6.9 +/- 0.3 5.7 +/- 0.2 Sample Site W-9 WSW-8 Sw-i SW-8 SSW-S SSW-lo S-5 S-10 SSE-1 SSE-10 NNE-22 Deployment 18-Sep-02 Collection 1 lDec 5.3 +/- 0.2 (A) 5.2 +/- 0.2 5.8 +/- 0.2 5.1 +/- 0.2 5.3 +/- 0.2 5.0 +/- 0.2 5.9 +/- 0.2 5.1 +/- 0.2 6.0 +/-0.2 6.6 +/- 0.3 (A) - The TLD at site WSW-8 was missing when collection was attempted. A new TLD was deployed.

2 of 7 Sample Site N-2 N-7 N-10 NNW-2 NNW-10 NW-1 NW-5 NW-10 WNW-10 W-1 W-S

TP QR024 2.a. IODINE-131 INWEEKLY AIR CARTRIDGES - (pCilm3)

Sample Site Collection Date 02-Oct-02 09-Oct-02 15-Oct-02 23-Oct-02 01-Nov-02 06-Nov-02 12-Nov-02 19-Nov-02 27-Nov-02 02-Dec-02 10-Dec-02 18-Dec-02 26-Dec-02 30-Dec-02 T51

<0.02

<0.03

<0.02

<0.02

<0.02

<0.04

<0.02

<0.01

<0.02

<0.04

<0.03

<0.02

<0.02

<0.03 T57

<0.02

<0.03

<0.02

<0.02

<0.02

<0.03

<0.02

<0.01

<0.02

<0.04

<0.04

<0.02

<0.02

<0.03 T58

<0.02

<0.03

<0.02

<0.02

<0.02

<0.03

<0.02

<0.01

<0.02

<0.04

<0.03

<0.02

<0.02

<0.03 T64

<0.02

<0.03

<0.02

<0.05

<0.02

<0.03

<0.02

<0.01

<0.03

<0.04

<0.03

<0.02

<0.02

<0.03 T72

<0.02

<0.03

<0.02

<0.02

<0.02

<0.07

<0.02

<0.01

<0.02

<0.04

<0.03

<0.02

<0.02

<0.03 3 of 7

TP QR02-4 2.b. 1. AIR PARTICULATES - GROSS BETA - (pCi/m3)

Sample Site T51 0.007 +/- 0.002 0.018 +/- 0.002 0.008 +/- 0.002 0.012 +/- 0.002 0.014 +/- 0.002 0.025 +/- 0.003 0.019 +/- 0.002 0.013 +/- 0.002 0.014 +/- 0.002 0.025 +/- 0.003 0.014 +/- 0.002 0.015 +/- 0.002 0.015 +/- 0.002 0.021 +/- 0.004 0.016 +/- 0.001 T57 0.008 + 0.002 0.019 +/- 0.002 0.011 + 0.002 0.013 +/- 0.002 0.011 +/- 0.002 0.024 +/- 0.003 0.021 +/- 0.003 0.013 +/- 0.002 0.016 +/- 0.002 0.026 +/- 0.003 0.016 +/- 0.002 0.017 +/- 0.002 0.017 +/- 0.002 0.016 + 0.003 0.016 + 0.001 T58 0.011 +/- 0.002 0.025 +/- 0.003 0.008 +/- 0.002 0.010 +/- 0.002 0.011 +/- 0.002 0.020 +/- 0.003 0.018 +/- 0.003 0.011 +/- 0.002 0.013 +/- 0.002 0.025 +/- 0.003 0.012 +/- 0.002 0.010 +/- 0.002 0.015 +/- 0.002 0.024 +/- 0.004 0.015 +/- 0.001 T64 0.011 +/- 0.002 0.024 +/- 0.003 0.010 +/- 0.002 0.014 +/- 0.004 0.010 +/- 0.002 0.022 +/- 0.003 0.007 +/- 0.002 0.018 +/- 0.002 0.019 +/- 0.002 0.024 +/- 0.003 0.013 +/- 0.002 0.016 +/- 0.002 0.019 +/- 0.002 0.028 +/- 0.004 0.017 +/- 0.001 T72 0.008 +/- 0.002 0.015 +/- 0.002 0.005 +/- 0.002 0.012 +/- 0.002 0.010 +/- 0.002 0.019 +/- 0.005 0.018 +/- 0.002 0.015 +/- 0.002 0.016 +/- 0.002 0.026 +/- 0.003 0.012 +/- 0.002 0.014 +/- 0.002 0.016 +/- 0.002 0.018 +/- 0.003 0.015 +/- 0.001 2.b.2. AIR PARTICULATES - GAMMA ANALYSIS OF OUARTERLY COMPOSITES (pCi/m3 )

Be-7 0.1385 +/- 0.0113 0.1377 +/- 0.0132 0.1406 +/- 0.0100 0.1629 +/- 0.0157 0.1523 +/- 0.0052 K-40 Cs-134 Cs-137

<0.0156

<0.0008

<0.0010

<0.0242

<0.0019

<0.0014

<0.0125

<0.0011

<0.0009

<0.0370

<0.0022

<0.0011

<0.0045

<0.0005

<0.0004 Pb-210 0.0261 +/- 0.0032

<0.0662 0.0175 +/- 0.0031

<0.0649

<0.0197 4 of 7 Collection Date 02-Oct-02 09-Oct-02 15-Oct-02 23-Oct-02 01-Nov-02 06-Nov-02 12-Nov-02 19-Nov-02 27-Nov-02 02-Dec-02 10-Dec-02 18-Dec-02 26-Dec-02 30-Dec-02 Mean:

Sample Site T51 T57 T58 T64 T72

TP QR02-4 3.a. SURFACE WATER - (pCi/L)

Sample Collection Zr-95 Ba-140 Site Date H-3 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 (A) 1-131 Cs-134 Cs-137 La-140 (B)

T42 28-Oct-02

<120 321 + 43

<5

<5

<11

<7

<14

<9

<7

<6

<6

<8 18-Nov-02

<125 297 +/- 32

<4

<4

<9

<5

<8

<6

<6

<4

<4

<4 05-Dec-02

<118 263 + 34

<3

<4

<6

<4

<8

<7

<5

<4

<4

<6 T67 30-Oct-02

<120 266 +/- 29

<3

<4

<8

<4

<8

<5

<4

<4

<4

<8 18-Nov-02

<125 159 + 15

<2

<2

<3

<2

<4

<3

<2

<2

<2

<3.

09-Dec-02

<118 283 +/- 33

<3

<3

<7

<4

<7

<5

<7

<3

<3

<5 T81 28-Oct-02

<120 332+/-45

<6

<5

<11

<7

<11

<12

<8

<6

<6

<9 18-Nov-02

<125 384 +/- 54

<6

<6

<9

<7

<12

<8

<7

<7

<7

<7 05-Dec-02

<118 315+/-31

<4

<4

<7

<4

<7

<6

<11

<5

<4

<6 (A) These tabulated LLD values for Zr/Nb-95 are the higher of the individual parent or daughter LLDs.

(B)

These tabulated LLD values are for Ba-140, either based on direct measurement of Ba-140 or based on ingrowth of La-140, whichever method yields the greater sensitivity for a given sample.

5 of 7

TP QR02-4 3.b. SEDIMENT - (pCi/kg. dry weight)

Sample Site Collection Date Be-7 K-40 Co-58 Co-60 Cs-134 Cs-137 Pb-210 Ra-226 U-238 These samples were previously collected.

4.a.1. CRUSTACEA - (pCi/kg. wet weight)

Sample Site T67 Collection Date K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Cs-134 Cs-137 Ra-226 Ra-228 This sample was previously collected.

1707 +/- 187

<21

<37

<101

<23

<45

<21

<17 918 +/- 187

<93 4.a.2. FISH - (pCi/kg, wet weight)

K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Cs-134 Cs-137 Ra-226 Ra-228 This sample was previously collected.

2263 +/- 213

<15

<24

<58

<26

<51

<21

<21

<314

<84 6 of 7 T81 05-Nov-02 Collection Date Sample Site T67 T81 03-Dec-02

TP QR02-4 4.b. BROADLEAF VEGETATION - Brazilian Pepper - (pCi/kg. wet weight)

Sample Site T40 T41 T67 Collection Date 30-Oct-02 18-Nov-02 09-Dec-02 30-Oct-02 18-Nov-02 09-Dec-02 30-Oct-02 18-Nov-02 09-Dec-02 Be-7 1352 +/- 105 754 +/- 61 1562 +/- 99 1011 +/- 88 1179 +/- 87 1317 +/- 91 1232 +/- 38 1213 +/- 113 1851 +/- 87 K-40 1745 + 158 3798 +/- 161 3383 +/- 156 4544 +/- 187 4671 +/- 198 4524 +/- 225 3674 +/- 75 3928 +/- 247 2809 +/- 134 1-131

<19

<16

<18

<18

<19

<22

<8

<27

<14 Cs-134

<18

<12

<12

<14

<15

<19

<6

<24

<11 Cs-137 59+/-13 38+/-5 133 +/- 10 101 10 122 +/- 12 44 +/- 10

<6

<22 48+/-6 Pb-210

<2730

<875

<933

<922

<1037

<2726 545 +/- 144

<3448

<716 Ra-226

<370

<284

<343

<300

<329

<370

<121

<462

<263 7 of 7

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT-UNITS 3 & 4 ATTACHMENT C RESULTS FROM THE INTERLABORATORY COMPARISON PROGRAM 2002 DEPARTMENT OF ENERGY QAP 56, June 2002 AND QAP 57, December 2002

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 DOE-QAP 56 RESULTS Reported Reported EML EML Reported Radionuclide Value Error Value Error EML Evaluation Matrix: Al Air Filter Bq/filter C060 34.370 0.180 30.520 0.652 1.126 W

CS137 29.210 0.160 28.230 0.701 1.035 A

GROSS ALPHA 0.440 0.020 0.534 0.053 0.824 W

GROSS BETA 1.220 0.030 1.300 0.130 0.936 A

MN54 87.870 0.290 38.530 0.867 2.281 N

Matrix: SO Soil Bq/kg CS137 1327.000 4.000 1326.670 66.510 1.000 A

K40 603.500 4.160 621.670 33.860 0.971 A

Matrix: VE Vegetation Bq/kg C060 1.092 0.027 11.230 0.677 0.097 N

CS137 30.770 0.220 313.667 15.910 0.098 N

K40 82.940 1.480 864.330 47.220 0.096 N

Matrix: WA Water Bq/L C060 345.100 0.420 347.330 12.400 0.994 A

CS134 3.440 0.160 3.357 0.200 1.025 A

CS137 57.300 0.230 56.067 2.929 1.022 A

GROSS BETA 1177.970 14.830 1030.000 103.000 1.144 A

H3 301.560 5.140 283.700 3.380 1.063 A

SR90 6.470 0.310 7.579 0.176 0.854 A

Evaluation : A = Acceptable, W = Acceptable with Warning, N = Not Acceptable

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 DOE-QAP 56 CORRECTED RESULTS Initial Lab Results Corrected lab Results EML Reported Reported Reported Reported Radionuclide Value Value EML Value EML Matrix: Al Air Filter Bq/filter C060 30.520 CS137 28.230 GROSS ALPHA 0.534 GROSS BETA 1.300 MN54 38.530 Matrix: VE Vegetation Bq/kg C060 11.230 CS137 313.667 K40 864.330 34.370 29.210 0.440 1.220 87.870 1.092 30.770 82.940 1.126 1.035 0.824 0.936 2.281 0.097 0.098 0.096 30.200 0.989 Not Applicable, was "A" Not a REMP analysis Not Applicable, was "A" 40.100 1.040 10.920 307.700 829.400 0.972 0.981 0.960 The Corrected Ratios Are in the "Acceptable" range.

2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT-UNITS 3 & 4 DOE-QAP 57 RESULTS Reported Radionuclide Value Matrix: Al Air Filter Bq/filter C060 24.650 CS137 36.310 MN54 58.590 Reported Error 3.100 0.740 1.070 EML Value 23.000 32.500 52.200 EML Reported Error EML 0.059 0.777 1.170 1.072 1.117 1.122 Matrix: SO CS137 K40 Matrix: VE C060 CS137 K40 Soil Bq/kg 884.300 686.860 Vegetation Bq/kg 9.200 294.000 1463.000 Matrix: WA Water Bq/L C060 276.300 CS134 59.010 CS137 86.050 GROSS ALPHA 221.160 GROSS BETA 744.630 H3 255.080 SR90 7.840 19.380 18.550 0.300 6.000 40.000 0.590 0.310 0.500 9.730 10.940 4.760 0.320 Evaluation : A = Acceptable, W = Acceptable with Warning, N = Not Acceptable Evaluation A

A A

1.066 1.077 0.952 0.978 0.989 A

A A

A A

829.330 637.670 9.660 300.670 1480.000 268.670 60.200 81.430 210.000 900.000 227.300 8.690 41.580 34.260 0.630 15.250 77.800 9.710 1.860 4.280 21.000 90.000 5.615 0.420 1.028 0.980 1.057 1.053 0.827 1.122 0.902 A

A A

A A

A A

-