ENS 58087
ENS Event | |
|---|---|
15:01 Oct 21, 2025 | |
| Title | Invalid Specified System Actuation |
| Event Description | The following information was provided by the licensee via phone and email:
This 60-day optional telephone notification is being made in lieu of a licensee event report submittal as allowed by 10 CFR 50.73(a)(1). This notification is made pursuant to the reporting requirements specified in 10 CFR 50.73(a)(2)(iv)(A) for an invalid actuation of one of the systems listed in 10 CFR 50.73(a)(2)(iv)(B). At approximately 1001 EDT on October 21, 2025, an invalid actuation of the 'B' train motor-driven auxiliary feedwater (MDAFW) pump occurred with Harris Nuclear Plant while in mode 6. After investigation [it was determined that] the pump automatic start signal was from the anticipated transient without scram mitigation system actuation circuitry (AMSAC). Restoration from functional testing of AMSAC was in progress at the time of the pump start. Separate surveillance testing of the 'B' train emergency safeguards sequencer was being prepared for and enabled the 'B' train MDAFW pump start while restoring 'B' MDAFW pump control power prior to the event. The 'B' train MDAFW pump started and ran with no abnormalities noted. The overlapping testing activities allowed for the AMSAC start signal to be sent to the 'B' MDAFW pump. The actuation was not initiated in response to actual plant conditions, it was not an intentional manual initiation, and there were no parameters satisfying the requirements for initiation of the system. Therefore, this event has been determined to be an invalid actuation. This event did not impact the health and safety of the public. The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| Harris North Carolina (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.73(a)(1), Submit an LER, Invalid Actuation | |
| Time - Person (Reporting Time:+1338.82 h55.784 days <br />7.969 weeks <br />1.834 months <br />) | |
| Opened: | Ash Brannan 10:50 Dec 16, 2025 |
| NRC Officer: | Sam Colvard |
| Last Updated: | Dec 16, 2025 |
| 58087 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 58087\u003C/a\u003E - \u003Ca href=\"/Harris\" title=\"Harris\"\u003EHarris\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EInvalid Specified System Actuation\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 58087 - Harris\n","link":"","lat":35.63344166666667,"lon":-78.95586666666667,"icon":"/w/images/7/75/Duke_Energy_icon.png"}],"imageoverlays":null} | |
WEEKMONTHYEARENS 580872025-10-21T15:01:00021 October 2025 15:01:00
[Table view]10 CFR 50.73(a)(1), Submit an LER Invalid Specified System Actuation ENS 471712011-06-21T17:08:00021 June 2011 17:08:00 10 CFR 50.73(a)(1), Submit an LER 60-Day Optional Telephonic Notification of Invalid Specified System Actuation ENS 464352010-11-10T05:24:00010 November 2010 05:24:00 10 CFR 50.73(a)(1), Submit an LER Telephone Notification in Lieu of Written Ler - Invalid Actuation of Motor Driven Auxiliary Feedwater Pump ENS 464672010-10-28T20:04:00028 October 2010 20:04:00 10 CFR 50.73(a)(1), Submit an LER Invalid Actuation of the "B" Emergency Service Water (Esw) Pump ENS 458382010-02-16T15:22:00016 February 2010 15:22:00 10 CFR 50.73(a)(1), Submit an LER Invalid Actuation of a Motor Driven Auxiliary Feedwater Pump 2025-10-21T15:01:00 | |