| Title | Agreement State Report - Found Nuclear Gauge in Scrap Yard |
| Event Description | The following was received by email from the state of Ohio:
The Bureau received a call on June 15 to report that a company working under reciprocity, Chase Environmental [license number 00004KY2001, Louisville, KY], had discovered a gauging device containing a Cs-137 source at the Cohen Brothers scrap yard in Middletown, Ohio. Chase Environmental packaged the gauge and took possession of the gauge for ultimate disposal. The shutter on the gauge appeared to be stuck open or non-existent. Dose rates of 407 mR/hr on contact with the area where the shutter should be, and 23.5 mR/hr at 1 foot were measured. No loose contamination was detected. No scrap yard personnel were exposed. The Cs-137 source is estimated at 6 mCi. No identifying information was visible on the gauge. A representative of the scrap yard said that they were cleaning up a section of the yard and a load of dirt with the gauge alarmed their radiation monitors on the way out. He said that this device could have been there for 10+ years. The origin of the gauge is unknown. The Bureau performed a survey of the scrap yard on June 16 with no other radioactive material detected. Ohio Item Number: OH200003 Ohio Reference Number: OH 2020-024 THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf |
| Where | |
|---|---|
| Ohio Bureau Of Radiation Protection Middletown, Ohio (NRC Region 3) | |
| Organization: | Ohio Bureau Of Radiation Protection |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+54.95 h2.29 days <br />0.327 weeks <br />0.0753 months <br />) | |
| Opened: | Michael Snee 10:57 Jun 17, 2020 |
| NRC Officer: | Bethany Cecere |
| Last Updated: | Jun 17, 2020 |
| 54747 - NRC Website | |
Ohio Bureau of Radiological Health and Safety with Agreement State | |||||
| Agreement State Report - Stolen Troxler Gauge ENS 549122020-09-16T04:00:00016 September 2020 04:00:00 Agreement State | Agreement State Report - Leaking Source ENS 548732020-08-28T04:00:00028 August 2020 04:00:00 Agreement State | Agreement State Report - Shutter Mechanism Malfunction ENS 548762020-08-27T04:00:00027 August 2020 04:00:00 Agreement State | Agreement State Report - Incorrect Dose Delivered to Patient ENS 547472020-06-15T04:00:00015 June 2020 04:00:00 Agreement State Agreement State Report - Found Nuclear Gauge in Scrap Yard ENS 547392020-06-04T04:00:0004 June 2020 04:00:00 Agreement State Agreement State Report - Source Delivered to the Wrong Facility ENS 544792020-01-14T05:00:00014 January 2020 05:00:00 Agreement State Agreement State Report - Cs-137 Source Found at a Scrap Yard ENS 490052013-04-19T04:00:00019 April 2013 04:00:00 Agreement State Agreement State Report - Found Orphan Radium Sources 2020-09-29T11:30:00 [Table view] | ||