ENS 52053
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
14:40 Jun 29, 2016 | |
| Title | |
| Event Description | At 0940 CDT on 6/29/2016, both doors of a Secondary Containment Airlock were reported to be open simultaneously for a period of less than 5 seconds. The brief time that the doors were simultaneously open constituted an inoperable condition of Secondary Containment. Secondary Containment was immediately restored to operable by closing the airlock doors. The airlock interlock was repaired and verified to operate correctly.
This event is being reported pursuant of 10 CFR 50.72(b)(3)(v)(C). The Senior Resident Inspector has been notified. |
| Where | |
|---|---|
| Duane Arnold Iowa (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material | |
| LER: | 05000331/LER-2016-001 Regarding Two Instances of Both Doors in Secondary Containment Airlock Opened Concurrently |
| Time - Person (Reporting Time:+2.68 h0.112 days <br />0.016 weeks <br />0.00367 months <br />) | |
| Opened: | Mark Dickerson 17:21 Jun 29, 2016 |
| NRC Officer: | Steve Sandin |
| Last Updated: | Jun 29, 2016 |
| 52053 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 52053\u003C/a\u003E - \u003Ca href=\"/Duane_Arnold\" title=\"Duane Arnold\"\u003EDuane Arnold\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003ESecondary Containment Inoperable\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 52053 - Duane Arnold\n","link":"","lat":42.10089166666667,"lon":-91.77759444444445,"icon":"/w/images/9/9b/NextEra_Energy_icon.png"}],"imageoverlays":null} | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Duane Arnold | |
WEEKMONTHYEARENS 534962018-07-09T05:00:0009 July 2018 05:00:00
[Table view]10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable ENS 525112017-01-26T09:00:00026 January 2017 09:00:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Containment Valves Failed Surveillance Testing ENS 520532016-06-29T14:40:00029 June 2016 14:40:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable ENS 520222016-06-19T20:33:00019 June 2016 20:33:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable ENS 513532015-08-27T12:52:00027 August 2015 12:52:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable ENS 509892015-04-16T18:20:00016 April 2015 18:20:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Secondary Containment Airlock Doors Open Simultaneously ENS 509142015-03-21T05:30:00021 March 2015 05:30:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Secondary Containment Doors Opened Simultaneously ENS 505602014-10-23T06:07:00023 October 2014 06:07:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable Due to Both Airlock Doors Open Simultaneously ENS 503752014-08-15T17:18:00015 August 2014 17:18:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Standby Gas Treatment System Inoperable ENS 501532014-05-30T12:59:00030 May 2014 12:59:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Airlock Inoperable for 10 Seconds ENS 498382014-02-18T15:44:00018 February 2014 15:44:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment ENS 496572013-12-18T14:30:00018 December 2013 14:30:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Doors in Secondary Containment Airlock Opened Concurrently ENS 482122012-08-20T20:20:00020 August 2012 20:20:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Rwcu System Isolation Differential Flow - High Function Inoperable ENS 477092012-02-29T18:22:00029 February 2012 18:22:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Isolation Dampers Fail to Close During Quarterly Surveillance ENS 417852005-06-20T08:08:00020 June 2005 08:08:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Standby Gas Treatment Trains Briefly Inoperable During Testing 2018-07-09T05:00:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_52053&oldid=82620"