ENS 48102
ENS Event | |
|---|---|
16:00 Jul 13, 2012 | |
| Title | Intermittent Signal Interference with Emergency Sirens |
| Event Description | At 12:00 on July 13, 2012 it was determined, during a conference call with the Exelon siren vendor, that Oyster Creek emergency planning zone (EPZ) sirens may be unreliable. The unreliability is being caused by an intermittent signal on the frequency used to activate the sirens. Therefore, an 8-hour report is required under 10 CFR 50.72(b)(3)(xiii) due to a potential 'Loss of Emergency Preparedness Capabilities.'
Additionally, Exelon is contacting the Federal Communications Commission (FCC) for troubleshooting and reporting purposes, as well as, the New Jersey Office of Emergency Management (NJ OEM) and the Ocean County Office of Emergency Management to institute compensatory actions. Due to contacting other government agencies a 4-hour report is required per 10 CFR 50.72(b)(2)(xi). Exelon will notify the NRC Operations Center upon full-restoration of the Oyster Creek EPZ siren system. The NRC Resident Inspector has been informed.
As of 2058 EDT on July 14, the licensee has declared that all 42 sirens have been restored to a reliable status. The siren vendor has shifted the activation frequency to avoid the interference. The vendor is still working with the FCC to determine the cause of the interference signal at the original frequency. The licensee has notified the NRC Resident Inspector. R1DO (Doerflein) notified. |
| Where | |
|---|---|
| Oyster Creek New Jersey (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
| Time - Person (Reporting Time:+-1.67 h-0.0696 days <br />-0.00994 weeks <br />-0.00229 months <br />) | |
| Opened: | Thomas Busk 14:20 Jul 13, 2012 |
| NRC Officer: | Charles Teal |
| Last Updated: | Jul 14, 2012 |
| 48102 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 48102\u003C/a\u003E - \u003Ca href=\"/Oyster_Creek\" title=\"Oyster Creek\"\u003EOyster Creek\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EIntermittent Signal Interference with Emergency Sirens\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 48102 - Oyster Creek\n","link":"","lat":39.81436111111111,"lon":-74.20560833333333,"icon":""}],"imageoverlays":null} | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Oyster Creek with 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
WEEKMONTHYEARENS 543472019-10-24T19:24:00024 October 2019 19:24:00
[Table view]10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 539772019-04-04T15:55:0004 April 2019 15:55:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Ventilation Non-Functional ENS 528612017-07-14T21:24:00014 July 2017 21:24:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of the Technical Support Center Ventilation System ENS 526742017-04-12T19:30:00012 April 2017 19:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of the Technical Support Center Ventilation System ENS 524652016-12-29T07:50:00029 December 2016 07:50:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Technical Suppport Center Ventilation System ENS 522302016-09-09T14:23:0009 September 2016 14:23:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to Local Authorities Due to Out-Of-Service Sewage Radiation Monitor ENS 520302016-06-21T20:46:00021 June 2016 20:46:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Sodium Hypochlorite Spill ENS 516772016-01-23T10:51:00023 January 2016 10:51:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Power to the Site Emergency Building ENS 516342016-01-04T11:00:0004 January 2016 11:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to an Emergency Diesel Engine Coolant Leak ENS 511082015-06-01T11:00:0001 June 2015 11:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Out of Service for Planned Maintenance ENS 502202014-06-23T13:00:00023 June 2014 13:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Communications Due to Planned Maintenance ENS 498692014-03-04T10:02:0004 March 2014 10:02:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Out of Service for Planned Maintenance ENS 498502014-02-22T21:37:00022 February 2014 21:37:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Concerning a Small Hydraulic Fluid Spill ENS 495702013-11-21T22:37:00021 November 2013 22:37:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to Njdep Concerning a Small Sodium Hypochlorite Spill ENS 492002013-07-17T20:05:00017 July 2013 20:05:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to a Chemical Spill Onsite ENS 488612013-03-28T12:04:00028 March 2013 12:04:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Ventilation Out of Service for Planned Maintenance ENS 486572013-01-08T10:05:0008 January 2013 10:05:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Technical Support Center Ventilation Maintenance ENS 484952012-11-08T15:20:0008 November 2012 15:20:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Planning Zone Sirens ENS 484602012-10-31T03:40:00031 October 2012 03:40:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to the National Marine Fisheries Service ENS 484502012-10-29T19:00:00029 October 2012 19:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of 21 Emergency Notification Sirens ENS 481252012-07-23T07:29:00023 July 2012 07:29:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event Due to Loss of Offsite Power ENS 481022012-07-13T16:00:00013 July 2012 16:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Intermittent Signal Interference with Emergency Sirens ENS 480522012-06-27T20:30:00027 June 2012 20:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Actuation of an Emergency Siren ENS 480242012-06-14T10:07:00014 June 2012 10:07:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Out of Service and Offsite Notification Due to Loss of Power to Site Emergency Building ENS 477462012-03-15T12:30:00015 March 2012 12:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Out of Service Due to Planned Maintenance ENS 475202011-12-12T21:50:00012 December 2011 21:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to State of New Jersey Due to High Opacity of Diesel Exhaust ENS 472132011-08-28T12:58:00028 August 2011 12:58:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Emergency Sirens Out of Service ENS 471072011-07-29T01:15:00029 July 2011 01:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Fish Kill Event ENS 464952010-12-20T13:05:00020 December 2010 13:05:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Fish Kill Caused by Rate of Temperature Change in Discharge Canal ENS 461992010-08-23T13:00:00023 August 2010 13:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Erds Capability ENS 459222010-05-13T09:00:00013 May 2010 09:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Partial Loss of Erds and Spds Due to Planned Maintenance ENS 458242010-04-08T04:00:0008 April 2010 04:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Stack Sample Line Separated at Fitting ENS 457662010-03-14T14:27:00014 March 2010 14:27:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Power to Emergency Operations Facility ENS 453862009-09-28T11:54:00028 September 2009 11:54:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Plant Process Computer Outage Resulting in a Loss of Erds and Spds ENS 452992009-08-25T23:35:00025 August 2009 23:35:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to a Water Leak Containing Tritium ENS 450332009-04-30T17:06:00030 April 2009 17:06:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Response Data System (Erds) Unavailable for Greater than 1 Hour ENS 449932009-04-15T20:44:00015 April 2009 20:44:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Potential Release of Tritium ENS 446882008-11-29T02:01:00029 November 2008 02:01:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Automatic Reactor Scram Due to Main Transformer Fault ENS 446122008-10-29T23:15:00029 October 2008 23:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to a Spill of a Hazardous Substance ENS 445262008-09-29T13:18:00029 September 2008 13:18:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Internal Phone Systems ENS 443342008-07-03T09:40:0003 July 2008 09:40:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Commercial Telephone and Dedicated Ep Landlines ENS 439892008-02-14T21:04:00014 February 2008 21:04:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to State of New Jersey ENS 438542007-12-19T16:45:00019 December 2007 16:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Manual Reactor Scram Due to Lowering Reactor Level ENS 435022007-07-18T19:49:00018 July 2007 19:49:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Spill of Ethylene Glycol Reported to State ENS 434952007-07-17T09:22:00017 July 2007 09:22:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Automatic Reactor Scram on Low Reactor Vessel Water Level (Rvwl) ENS 433382007-05-03T05:46:0003 May 2007 05:46:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Release to Environment ENS 432492007-03-19T22:16:00019 March 2007 22:16:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Made to New Jersey Department of Environmental Protection ENS 431072007-01-19T19:10:00019 January 2007 19:10:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Press Release ENS 430532006-12-15T22:15:00015 December 2006 22:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Press Release for Low Levels of Cesium-137 Contamination Identified on Site ENS 422932006-01-29T09:40:00029 January 2006 09:40:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 421552005-11-19T02:19:00019 November 2005 02:19:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Lost Power to Circulating Water Dilution Pump Elevating Discharge Temperatures to Bay ENS 421532005-11-18T04:00:00018 November 2005 04:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss and Recovery of Communications ENS 417412005-06-02T01:09:0002 June 2005 01:09:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Reactor Scram Due to Generator Trip/Turbine Trip Following Offsite Electical Transient ENS 410392004-09-14T19:00:00014 September 2004 19:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to State of New Jersey ENS 409652004-08-17T17:15:00017 August 2004 17:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Possible Discharge Permit Violation ENS 408082004-06-11T19:10:00011 June 2004 19:10:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Oil Laden Water Into Storm Drain ENS 406562004-04-08T16:55:0008 April 2004 16:55:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Press Release Regarding Law Suite Settlement ENS 401972003-09-24T18:55:00024 September 2003 18:55:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Recovery of Live Sea Turtle 2019-04-04T15:55:00 | |